• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Generation Of 12-Sided And 18-Sided Polygonal Voltage Space Vectors For Inverter Fed Induction Motor Drives By Cascading Conventional Two-Level Inverters

Lakshminarayanan, Sanjay 06 1900 (has links)
Multi-level inverters play a significant role in high power drive systems for induction motors. Interest in multi-level inverters started with the three-level, neutral point clamped (NPC) inverter. Now there are many topologies for higher number of levels such as the, flying capacitor and cascaded H-bridge etc. The advantage of multi-level inverters is the reduced voltage stress on the switching devices, lower dv/dt and lower harmonic content. The voltage space vector structure in a multi-level inverter has a hexagonal periphery similar to that in a two-level inverter. In the over-modulation region in multi-level inverters, there is the presence of lower order harmonics such as 5th and 7th in the output voltage, and this can be avoided by using a voltage space vector scheme with more than six polygonal voltage space vectors such as 12, 18, 24 etc. These polygonal voltage space vectors can be generated by using multi-level inverter topologies, by cascading two-level inverter structures with asymmetric DC-links. This thesis deals with the development of 12-sided and 18-sided polygonal voltage space vector schemes for induction motor drives. With the 12-sided polygonal structure, all the 5th and 7th harmonic orders and 6n±1, n=1, 3, 5.. are absent throughout the modulation range, and in the 18-sided voltage space vector scheme, 5th, 7th, 11th and 13th harmonics are absent throughout the modulation range. With the absence of the low order frequencies in the proposed polygonal space vector structures, high frequency PWM schemes are not needed for voltage control. This is an advantage over conventional schemes. Also, due to the absence of lower order harmonics throughout the modulation range, special compensated synchronous reference frame PI controllers are not needed in current controlled vector control schemes in over-modulation. In this thesis a method is proposed for generating 12-sided polygonal voltage space vectors for an induction motor fed from one side. A cascaded combination of three two-level inverters is used with asymmetrical DC-links. A simple space vector PWM scheme based only on the sampled reference phase amplitudes are used for the inverter output voltage control. The reference space vector is sampled at different sampling rates depending on the frequency of operation. The number of samples in a sector is chosen to keep the overall switching frequency around 1kHz, in order to minimize switching losses. The voltage space vectors that make up the two sides of the sector in which the reference vector lies, are time averaged using volt-sec balance, to result in the reference vector. In the proposed 12-sided PWM scheme all the harmonics of the order 6n±1, n=1, 3, 5... are eliminated from the phase voltage, throughout the modulation range. In multi-level inverters steps are taken to eliminate common-mode voltage. Common-mode voltage is defined as one third of the sum of the three pole voltages of the inverter for a three phase system. Bearings are found to fail prematurely in drives with fast rising voltage pulses and high frequency switching. The alternating common-mode voltage generated by the PWM inverter contributes to capacitive couplings from stator body to rotor body. This generates motor shaft voltages causing bearing currents to flow from rotor to stator body and then to the ground. There can be a flashover between the bearing races. Also a phenomenon termed EDM (Electro-discharge machining) effect occurs and may damage the bearings. Common-mode voltage has to be eliminated in order to overcome these effects. In multi-level inverters redundancy of space vector locations is used to eliminate common-mode voltages. In the present thesis a 12-sided polygonal voltage space vector based inverter with an open-end winding induction motor is proposed, in which the common-mode voltage variation at the poles of the inverter is eliminated. In this scheme, there is a three-level inverter on each side of the open-end winding of the induction motor. The three-level inverter is made by cascading two, two-level inverters with unequal DC-link voltages. Appropriate space vectors are selected from opposite sides such that the sum of the pole voltages on each side is a constant. Also during the PWM operation when the zero vector is applied, identical voltage levels are used on both sides of the open-end windings, in order to make the phase voltages zero, while the common-mode voltage is kept constant. This way, common-mode voltage variations are eliminated throughout the modulation range by appropriately selecting the voltage vectors from opposite ends. In this method all the harmonics of 6n±1, n=1, 3, 5.. and triplen orders are eliminated. In the 12-sided polygonal voltage space vector methods, the 11th and 13th harmonics though attenuated are not eliminated. In the 18-sided polygonal voltage space vector method the 11th and 13th harmonics are eliminated along with the 5th and 7th harmonics. This scheme consists of an open-end winding induction motor fed from one side by a two-level inverter and the other side by a three-level inverter comprising of two cascaded two-level inverters. Asymmetric DC-links of a particular ratio are present. The 12-sided and 18-sided polygonal voltage space vector methods have been first simulated using SIMULINK and then verified experimentally on a 1.5kW induction motor drive. In the simulation as well as the experimental setup the starting point is the generation of the three reference voltages v, vB and vC . A method for determining the sector in which the reference vector lies by comparing the values of the scaled sampled instantaneous reference voltages is proposed. For the reference vector lying in a sector between the two active vectors, the first vector is to be kept on for T1 duration and the second vector for T2 duration. These timing durations can be found from the derived formula, using the sampled instantaneous values of the reference voltages and the sector information. From the pulse widths and the sector number, the voltage level at which a phase in the inverter has to be maintained is uniquely determined from look-up tables. Thus, once the pole voltages are determined the phase voltages can be easily determined for simulation studies. By using a suitable induction motor model in the simulation, the effect of the PWM scheme on the motor current can be easily obtained. The simulation studies are experimentally verified on a 1.5kW open-end winding induction motor drive. A V/f control scheme is used for the study of the drive scheme for different speeds of operation. A DSP (TMS320LF2407A) is used for generating the PWM signals for variable speed operation. The 12-sided polygonal voltage space vector scheme with the motor fed from a single side has a simple power bus structure and it is also observed that the pole voltage is clamped to zero for 30% of the time duration of one cycle of operation. This will increase the overall efficiency. The proposed scheme eliminates all harmonics of the order 6n±1, n=1, 3, 5…for the complete modulation range. The 12-sided polygonal voltage space vector scheme with common-mode elimination requires the open-end winding configuration of the induction motor. Two asymmetrical DC-links are required which are common to both sides. The leg of the high voltage inverter is seen to be switched only for 50% duration in a cycle of operation. This will also reduce switching losses considerably. The proposed scheme not only eliminates all harmonics of the order 6n±1, n=1, 3, 5…for the complete modulation range, but also maintains the common-mode voltage on both sides constant. The common-mode voltage variation is eliminated. This eliminates bearing currents and shaft voltages which can damage the motor bearings. In the 18-sided polygonal voltage space vector based inverter, the 11th and 13th harmonics are eliminated along with the 5th and 7th. Here also an open-end winding induction motor is used, with a two-level inverter on one side and a three-level inverter on the other side. A pole of the two-level inverter is at clamped to zero voltage for 50% of the time and a pole of the three-level inverter is clamped to zero for 30% of the time for one cycle of operation. The 18-sided polygonal voltage space vectors show the highest maximum peak fundamental voltage in the 18-step mode of 0.663Vdc compared to 0.658Vdc in the 12-step mode of the 12-sided polygonal voltage space vector scheme and 0.637Vdc in the six-step mode of a two-level inverter or conventional multi-level inverter (where Vdc is the radius of the space vector polygon). Though the schemes proposed are verified on a low power laboratory prototype, the principle and the control algorithm development are general in nature and can be easily extended to induction motor drives for high power applications.
2

Multilevel Voltage Space Vector Generation For Induction Motor Drives Using Conventional Two-Level Inverters And H-Bridge Cells

Siva Kumar, K 01 1900 (has links) (PDF)
Multilevel voltage source inverters have been receiving more and more attention from the industry and academia as a choice for high voltage and high power applications. The high voltage multilevel inverters can be constructed with existing low voltage semiconductor switches, which already have a mature technology for handling low voltages, thus improving the reliability of the overall inverter system. These multilevel inverters generate the output voltage in the form of multi-stepped waveform with smaller amplitude. This will result in less dv/dt at the motor inputs and electromagnetic interference (EMI) caused by switching is considerably less. Because of the multi-stepped waveform, the instantaneous error in the output voltage will be always less compared to the conventional two-level inverter output voltage. It will reduce the unwanted harmonic content in the output voltage, which will enable to switch the inverter at lower frequencies. Many interesting multi level inverter topologies are proposed by various research groups across the world from industry and academic institutions. But apart from the conventional 3-level NPC and H-bridge topology, others are not yet highly preferred for general high power drives applications. In this respect, two different five-level inverter topologies and one three-level inverter topology for high power induction motor drive applications are proposed in this work. Existing knowledge from published literature shows that, the three-level voltage space vector diagram can be generated for an open-end winding induction motor by feeding the motor phase windings with two two-level inverters from both sides. In such a configuration, each inverter is capable of assuming 8 switching states independent of the other. Therefore a total of 64 switching combinations are possible, whereas the conventional NPC inverter have 27 possible switching combinations. The main drawback for this configuration is that, it requires a harmonic filter or isolated voltage source to suppress the common mode currents through the motor phase winding. In general, the harmonic filters are not desirable because, it is expensive and bulky in nature. Some topologies have been presented, in the past, to suppress the common mode voltage on the motor phase windings when the both inverters are fed with a single voltage source. But these schemes under utilize the dc-link voltage or use the extra power circuit. The scheme presented in chapter-3 eliminates the requirement of harmonic filter or isolated voltage source to block the common mode current in the motor phase windings. Both the two-level inverters, in this scheme, are fed with the same voltage source with a magnitude of Vdc/2 where Vdc is the voltage magnitude requires for the NPC three-level inverter. In this scheme, the identical voltage profile winding coils (pole pair winding coils), in the four pole induction motor, are disconnected electrically and reconnected in two star groups. The isolated neutrals, provided by the two star groups, will not allow the triplen currents to flow in the motor phase windings. To apply identical fundamental voltage on disconnected pole pair winding, decoupled space vector PWM is used. This PWM technique eliminates the first center band harmonics thereby it will allow the inverters to operate at lower switching frequency. This scheme doesn’t require any additional power circuit to block the triplen currents and also it will not underutilize the dc-bus voltage. A five-level inverter topology for four pole induction motor is presented in chapter-3. In this topology, the disconnected pole pair winding coils are effectively utilized to generate a five-level voltage space vector diagram for a four pole induction motor. The disconnected pole pair winding coils are fed from both sides with conventional two-level inverters. Thereby the problems like capacitor voltage balancing issues are completely eliminated. Three isolated voltage sources, with a voltage magnitude of Vdc/4, are used to block the triplen current in the motor phase windings. This scheme is also capable of generating 61 space vector locations similar to conventional NPC five-level inverter. However, this scheme has 1000 switching combinations to realize 61 space vector locations whereas the NPC five-level inverter has 125 switching combinations. In case of any switch failure, using the switching state redundancy, the proposed topology can be operated as a three-level inverter in lower modulation index. But this topology requires six additional bi-directional switches with a maximum voltage blocking capacity of Vdc/8. However, it doesn’t require any complicated control algorithm to generate the gating pulses for bidirectional switches. The above presented two schemes don’t require any special design modification for the induction machine. Although the schemes are presented for four pole induction motor, this technique can be easily extend to the induction motor with more than four poles and thereby the number of voltage levels on the phase winding can be further increased. An alternate five-level inverter topology for an open-end winding induction motor is presented in chapter-4. This topology doesn’t require to disconnect the pole pair winding coils like in the previous propositions. The open-end winding induction motor is fed from one end with a two-level inverter in series with a capacitor fed H-bridge cell, while the other end is connected to a conventional two-level inverter to get a five voltage levels on the motor phase windings. This scheme is also capable of generating a voltage space vector diagram identical to that of a conventional five-level inverter. A total of 2744 switching combinations are possible to generate the 61 space vector locations. With such huge number switching state redundancies, it is possible to balance the H-bridge capacitor voltage for full modulation range. In addition to that, the proposed topology eliminates eighteen clamping diode having different voltage ratings compared to the NPC inverter. The proposed topology can be operated as a three-level inverter for full modulation range, in case of any switch failure in the capacitor fed H-bridge cell. All the proposed topologies are experimentally verified on a 5 h.p. four pole induction motor using V/f control. The PWM signals for the inverters are generated using the TMS320F2812 and GAL22V10B/SPARTAN XC3S200 FPGA platforms. Though the proposed inverter topologies are suggested for high-voltage and high-power industrial IM drive applications, due to laboratory constraints the experimental results are taken on the 5h.p prototypes. But all the proposed schemes are general in nature and can be easily implemented for high-voltage high-power drive applications with appropriate device ratings.
3

Investigations On PWM Signal Generation And Common Mode Voltage Elimination Schemes For Multi-Level Inverter Fed Induction Motor Drives

Kanchan, Rahul Sudam 08 1900 (has links) (PDF)
No description available.
4

Reduced Switch Count Multi-Level Inverter Structures With Common Mode Voltage Elimination And DC-Link Capacitor Voltage Balancing For IM Drives

Mondal, Gopal 07 1900 (has links)
Multilevel inverter technology has emerged recently as a very important alternative in the area of high-power medium-voltage energy control. Voltage operation above semiconductor device limits, lower common mode voltages, near sinusoidal outputs together with small dv/dt’s, are some of the characteristics that have made this power converters popular for industry and modern research. However, the existing solutions suffer from some inherent drawbacks like common mode voltage problem, DC-link capacitor voltage fluctuation etc. Cascaded multi-level inverter with open-end winding induction motor structure promises significant improvements for high power medium-voltage applications. This dissertation investigates such cascaded multi-level inverters for open-end winding induction motor drive with reduced switch count. Similar to the conventional two-level inverters, other multi-level inverters with PWM control generate alternating common mode voltage (CMV). The alternating common mode voltage coupled through the parasitic capacitors in the machine and results in excessive bearing current and shaft voltage. The unwanted shaft voltage may cross the limit of insulation breakdown voltage and cause motor failure. This alternating common mode voltage adds to the total leakage current through ground conductor and acts as a source of conducted EMI which can interfere with other electronic equipments around. As the number of level increase in the inverter, different voltage levels are made available by using DC-link capacitor banks, instead of using different isolated power supplies. The intermediate-circuit capacitor voltages which are not directly supplied by the power sources are inherently unstable and require a suitable control method for converter operation, preferably without influence on the load power factor. Apart from normal operation, the sudden fault conditions may occur in the system and it is necessary to implement the control strategy considering this condition also. A five-level inverter topology with cascaded power circuit structure is proposed in this dissertation with the strategy to eliminate the common mode voltage and also to maintain the balance in the DC-link capacitor voltages. The proposed scheme is based on a dual five-level inverter for open-end winding induction motor. The principle achievement of this work is the reduction of power circuit complexity in the five-level inverter compared to a previously proposed five-level inverter structure for open-end winding IM drive with common mode voltage elimination. The reduction in the number of power switching devices is achieved by sharing the two two-level inverters for both the inverter structures. The resultant inverter structure can produce a nine-level voltage vector structure with the presence of alternating common mode voltage. The inverter structure is formed by cascading conventional two-level inverters together with NPC three-level inverters. Thus it offers modular and simpler power bus structure. As the power circuit is realised by cascading conventional two-level and NPC three-level inverters the number of power diodes requirements also reduced compared to the conventional NPC five-level inverters. The present proposed structure is implemented for the open-end winding induction motor and the power circuit offers more number of switching state redundancies compared to any conventional five-level inverter. The inverter structure required half the DC-link voltage compared to the DC-link voltage required for the conventional five-level inverter structure for induction motor drive and this reduces the voltage stress on the individual power devices. The common mode voltage is eliminated by selecting only the switching states which do not generate any common mode voltage in pole voltages hence there will be no common mode voltage at the motor phase also. The technique of using the switching state selection for the common mode voltage elimination, cancels out the requirement of the filter for the same purpose. As the inverter output is achieved without the presence of common mode voltage, the dual inverter can be fed from the common DC-link sources, without generating any zero sequence current. Hence the proposed dual five-level inverter structure requires only four isolated DC supplies. The multi-level inverters supplied by single power supply, have inherent unbalance in the DC-link capacitor voltages. This unbalance in the DC-link capacitor voltages causes lower order harmonics at the inverter output, resulting in torque pulsation and increased voltage stress on the power switching devices. A five-level inverter with reduced power circuit complexity is proposed to achieve the dual task of eliminating common mode voltage and DC-link capacitor voltage balancing. The method includes the analysis of current through the DC-link capacitors, depending on the switching state selections. The conditions to maintain all the four DC-link capacitor voltages are analysed. In an ideal condition when there is no fault in the power circuit the balance in the capacitor voltages can be maintained by selecting switching states in consecutive intervals, which have opposite effect on the capacitor voltages. This is called the open loop control of DC-link capacitor voltage balancing, since the capacitor voltages are not sensed during the selection of the switching states. The switching states with zero common mode voltages are selected for the purpose of keeping the capacitor voltages in balanced condition during no fault condition. The use of any extra hardware is avoided. The proposed open loop control of DC-link capacitor voltage balancing is capable of keeping the DC-link capacitor voltages equal in the entire modulation region irrespective of the load powerfactor. The problem with the proposed open loop control strategy is that, it can not take any corrective action if there is any initial unbalance in the capacitor voltages or if any unbalance occurs in the capacitor voltages during operation of the circuit,. To get the corrective action in the capacitor voltages due occurrence of any fault in the circuit, the strategy is further improved and a closed loop control strategy for the DC-link capacitor voltages is established. All the possible fault conditions in the four capacitors are identified and the available switching states are effectively used for the corrective action in each fault condition. The strategy is implemented such a way that the voltage balancing can be achieved without affecting the output fundamental voltage. The proposed five-level inverter structure presented in this thesis is based on a previous work, where a five-level inverter structure is proposed for the open-end winding induction motor. In that previous work 48 switches are used for the realization of the power circuit. It is observed that all the available switching states in this previous work are not used for any of the performance requirement of CMV elimination or DC-link voltage balancing. So, in this proposed work, the power circuit is optimized by reducing some of the switches, keeping the performance of the inverter same as the power circuit proposed in the previous work. The five-level inverter proposed in this thesis used 36 switches and the number of switching states is also reduced. But, the available switching states are sufficient for the CMV elimination and DC-link capacitor voltage balancing. The advantage of the modular circuit structure of this proposed five-level inverter is further investigated and the inverter structure is modified to a seven-level inverter structure for the open end winding induction motor. The proposed power circuit of the seven-level inverter uses only 48 switches, which is less compared to any seven-level inverter structure for the open end winding induction motor with common mode voltage elimination. The power circuit is reduced by sharing four two-level inverters to both the individual seven-level inverters in both the sides of the of the open end winding induction motor. The cascaded structure eliminates the necessity of the power diodes as required by the conventional NPC multilevel inverters. The proposed seven-level inverter is capable of producing a thirteen-level voltage vector hexagonal structure with the presence of common mode voltage. The common mode voltage elimination is achieved by selecting only the switching states with zero common mode voltage from both the inverters and the combined inverter structure produce a seven-level voltage vector structure with zero common mode voltage. The switching frequency is also reduced for the seven-level inverter compared to the proposed five-level inverter. The advantage of this kind of power circuit structure is that the number of power diode requirement is same in both five-level and seven-level inverters. Since there is no common mode voltage in the output voltages, the dual seven-level inverter structure can be implemented with the common DC-link voltage sources for both the sides. Six isolated power supplies are sufficient for both the seven-level inverters. The available switching states in this proposed seven-level inverter are further analysed to implement the open loop and closed loop capacitor voltage balancing and this allow the power circuit to run with only three isolated DC supplies. All the proposed work presented in this thesis are initially simulated in SIMULINK toolbox and then implemented in a form of laboratory prototype. A 2.5KW open end winding induction motor is used for the implementation of these proposed works. But all these work general in nature and can be implemented for high power drive applications with proper device ratings.

Page generated in 0.074 seconds