• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 326
  • 183
  • 46
  • 29
  • 22
  • 11
  • 9
  • 8
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 800
  • 248
  • 108
  • 108
  • 84
  • 81
  • 81
  • 77
  • 70
  • 66
  • 65
  • 64
  • 63
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion test

Kuguimiya, Rosiane Nogueira 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
152

Estudo da eficiência de aparelhos para fotopolimerizar resinas odontológicas. / Analysis of the efficiency from visible-light sources used to polimerize odontological resins.

Silva, Ines Regina 04 October 1993 (has links)
Neste trabalho foram caracterizados cinco fotopolimerizadores, Visilux 2, Resilux, Fibralux, Translux III e Primelite. Inicialmente foram obtidos os espectros de emissão das cinco fontes de luz com um monocromador, e a estes espectros foram ajustadas funções gaussianas. Os melhores ajustes foram obtidos com um somatório de funções gaussianas, que originaram uma função matemática característica para cada uma das fontes de luz. Foi obtido também o espectro de absorção ótica da resina composta utilizada, no intervalo de 350-600 nm do espectro eletromagnético, e observou-se que havia uma absorção maior para comprimentos de onda menores. Foram calculados os valores dos coeficientes de atenuação linear para as lamínulas e para as amostras de resina, e observou-se que para uma mesma fonte de luz, haviam variações dos valores do coeficiente de atenuação linear para as diferentes espessuras, tanto das lamínulas como das amostras, concluindo-se que o sistema não estava em equilíbrio. As fontes de luz utilizadas foram ordenadas de acordo com a sua eficiência na polimerização da resina, através dos valores de dureza durante a polimerização da amostra, na seguinte ordem: Visilux 2, Translux III, Resilux, Fibralux, Primelite. / In this work, five photopolymerizators was characterized, Visilux 2, Resilux, Fibralux, Translux III and Primelite. Initially the emission specter from five light sources was obtained with a monochromator, and to these specters was adjusted gaussians functions. The better adjustments was obtained with a sum of gaussian functions, originating a caracteristic mathematical function to each light source. The resin's optical absortion specter was obtained in the 350-600 nm interval from eletromagnetic specter, and was observed that was greater absorption for smaller weavelength. The values of linear attenuation coefficient from slabs and samples was calculated, and was observed that for one light source, there was variations in the values of linear attenuation coefficient to differents thicknesses, both to the slabs and the samples, concluding that the sistem was not in equilibrium. The light sources used was disposed in agreement to their efficience in the resin's polymerization, through the values of the hardness during the photopolymerization, in the order: Visilux 2, Translux III, Resilux, Fibralux and Primelite.
153

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Mendonça, Luana Menezes de 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
154

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Freitas, Maria Cristina Carvalho de Almendra 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
155

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Lobo, Tamile Rocha da Silva 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
156

Comparação entre diferentes métodos para produção e análise de lesão de cárie artificial em esmalte e dentina / Comparison of different methods to produce and to analyze artificial enamel and dentin caries lesion

Moron, Bruna Mangialardo 26 September 2011 (has links)
Este trabalho comparou diferentes protocolos para a produção de lesão de cárie artificial em esmalte e dentina bovinos entre si e com lesões cariosas naturais (para o esmalte), utilizando análises de dureza superficial e longitudinal e microradiografia transversal, as quais foram relacionadas. Para o estudo in vitro, 40 espécimes de esmalte foram desmineralizados com: GEL MC (gel de metilcelulose 8% e ácido lático 0,1M, pH 4,6, 37ºC, 14 dias); GEL PA (solução de ácido poliacrílico - carbopol 0,2% e ácido lático 0,1M saturado com hidroxiapatita, pH 4,8, 37ºC, 16h); MDHP (solução de ácido lático 0,05M com cálcio, fosfato e tetraetil metilenodifosfanato, pH 5,0, 37ºC, 6 dias); e TAMPÃO (solução de ácido acético 0,05M com cálcio, fosfato e fluoreto, pH 5,0, 37ºC, 16h). Já os 60 espécimes de dentina foram desmineralizados com: GEL MC II (gel de carboximetilcelulose 6% e ácido lático 0,1M, pH 5,0, 37ºC, 14 dias); TAMPÃO II (solução de ácido acético 0,05M com cálcio, fosfato e fluoreto, pH 4,5, 37ºC, 7 dias); TAMPÃO III (solução de ácido acético 0,05M com cálcio e fosfato, pH 5,0, 37ºC, 7 dias) e MDHP II (solução de ácido lático 0,05M com cálcio, fosfato e tetraetil metilenodifosfanato, pH 5,0, 37ºC, 7 dias). No estudo in situ participaram 11 voluntários os quais utilizaram dispositivos palatinos de resina acrílica contendo dois espécimes de esmalte e dois de dentina bovinos, protegidos com uma tela plática, por 14 dias. Durante este período, os voluntários gotejaram uma solução de sacarose a 20% 8x/dia sobre o esmalte e 4x/dia sobre a dentina, para o desenvolvimento do biofilme. A desmineralização foi avaliada por dureza superficial-SH e longitudinal-CSH (KgF/mm2) e microradiografia transversal-TMR (%vol min). Foram ainda comparadas as lesões produzidas artificialmente em esmalte com as lesões naturais (mancha branca) de dentes extraídos. Os dados de CSH e TMR foram relacionados a cada distância e também submetidos individualmente à análise de variância para comparação entre os protocolos (p<0,05). Verificou-se que os diversos protocolos produziram diferentes tipos de lesões cariosas artificiais em esmalte e dentina. O grupo IN SITU, para ambos os substratos, produziu uma lesão profunda, com grande perda mineral integrada, porém com a menor camada superficial pseudo intacta. Já os grupos GEL MC I e II produziram lesões mais rasas e com menor perda mineral integrada. Os grupos MDHP I e II assim como TAMPÃO I, II e III produziram lesões subsuperficiais em esmalte e dentina. No geral, as lesões produzidas em dentina foram mais profundas e mais desmineralizadas quando comparadas ao esmalte. As lesões de mancha branca apresentaram-se com grande variabilidade em relação à profundidade e presença de camada superficial. Quanto ao método de avaliação, não houve uma relação linear entre CSH e TMR. Com base nos resultados, pode-se concluir que os métodos para produção de lesão cariosa diferem significativamente em relação às características de dureza e conteúdo mineral, podendo ter um impacto em uma subsequente des-remineralização e os métodos de análise não apresentam relação linear, sendo que a dureza deve ser interpretada criteriosamente em relação à perda mineral. / This study compared different methods to produce artificial dental caries in bovine enamel and dentin among them and with natural carious lesions (white sport lesion for enamel only) using surface and cross section hardness and transversal microradiography tests, which were submitted to relation analyses. For the in vitro study, 40 bovine enamel specimens were demineralized with: MC GEL (8% methylcellulose gel and 0.1M lactic acid, pH 4.6, 37ºC, 14 days), PA GEL (0,2% poliacrilic acid - carbopol and 0.1M lactic acid saturated with hydroxyapatite, pH 4.8, 37°C, 16h); MDHP (0,05M lactic acid solution with calcium, phosphate and tetraethyl methyl diphosphonate, pH 5.0, 37ºC, 6 days) and BUFFER (0.05M acetic acid solution with calcium, phosphate and fluoride, pH 5.0, 37ºC, 16h). Sixty dentin specimens were demineralized with: MC GEL (6% carboximetilcelulose gel and 0.1M lactic acid, pH 5.0, 37ºC, 14 days); BUFFER II (0.05M acetic acid solution with calcium, phosphate and fluoride, pH 4.5, 37ºC, 7 days); BUFFER III (0.05M acetic acid solution with calcium and phosphate, pH 5.0, 37ºC, 7 days) and MDHP II (0.05M actic acid with calcium, phosphate and tetraethyl methyl diphosphonate, pH 5.0, 37ºC, 7 days). For the in situ study, 11 volunteers wore acrylic resin palatal appliances containing two bovine enamel and dentin specimens, protected with plastic mesh, for 14 days. During this period, the volunteers dripped a 20% sucrose solution 8 times/day on enamel and 4 times/day on dentin, for the development of biofilm. Demineralization was assessed by surface (SH), cross-sectional (CSH) hardness and transversal microradiography (TMR). In addition, comparisons were made between artificially enamel caries lesions and natural lesions. The CSH and TMR data were correlated to each distance and also individually subjected to analysis of variance for comparison between protocols (p<0.05). It was found that the different protocols produced different types of artificial caries lesions in both enamel and dentin. The IN SITU protocol, for both substrates, produced a deep lesion with high integrated mineral loss, but with a thin surface layer. MC GEL I and II produced shallow lesions with low integrated mineral loss. MDHP I and II as well as BUFFER I, II and III protocols produced subsurface lesions in enamel and dentin. In general, the lesions produced in dentin were deeper and more demineralized when compared to enamel. The white spot lesions presented a high variability regarding lesion depth and surface layer. It was not found a linear relationship between CSH and TMR. Based on the results, it can be concluded that the protocols to produce artificial caries lesion significantly differ regarding hardness and mineral content, which in turn can influence further de-remineralization processes. The response variables do not present a linear relationship. Thus, hardness analysis should be carefully interpreted in respect to mineral loss.
157

"Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos" / STUDIES OF THE DEVELOPMENT AND CHARACTERIZATION OF THE Cu-Ni-Pt AND Cu-Ni-Sn ALLOYS FOR ELETRO-ELECTRONIC USES

Silva, Luis Carlos Elias da 04 October 2006 (has links)
O Cu e suas ligas têm diferentes aplicações na sociedade moderna devido as excelentes propriedades elétricas, condutividade térmica, resistência à corrosão dentre outras propriedades. Estas aplicações podem ser em válvulas, tubulações, panelas para absorção de energia solar, radiadores para automóveis, condutores de corrente e eletrônico, elementos de termostatos e partes estruturais de reatores nucleares, como, por exemplo, bobinas para campo toroidal para um reator de fusão nuclear. Dentre as ligas utilizadas em reatores nucleares, podemos destacar Cu-Be, Cu-Sn e Cu-Pt. O Ni e o Co, freqüentemente são adicionados às ligas de Cu para que a solubilidade seja deslocada para temperaturas mais elevadas com relação aos sistemas binários de Cu-Sn e Cu-Pt. A adição de Ni-Pt ou Ni-Sn ao Cu em porcentagens iguais ou inferiores a 1,5 % aliado a tratamentos termos-mecânico alteram as propriedades do Cu. Estudamos neste trabalho sete diferentes ligas: três ligas de Cu-Ni-Pt 1 (97,99 % Cu - 1,55 % Ni - 0,46 % Pt), 2 (99,33 % Cu - 0,23 % Ni -0,43 % Pt) 3 (98,01 % Cu - 0,48 % Ni - 1,51 % Pt); três ligas de Cu-Ni-Sn 4 (98,31% Cu - 1,12 % Ni - 0,58 % Sn), 5 (98,79 % Cu – 0,57 % Ni - 0,65 % Sn), 6 (98,39% Cu – 0,46 % Ni – 1,16 % Sn) e Cu eletrolítico 0 (0,0058 % Pb - 0,0007 % Fe - 0,0036 % Ni - 0,0024 % Ag). As referentes ligas foram desenvolvidas a partir de um forno a arco voltaico e passaram por tratamentos termo-mecânicos pré-determinados. As microestruturas foram analisadas diretamente por microscopia óptica e microscopia eletrônica de varredura / EDS e indiretamente por medidas de dureza Vickers e condutividade elétrica. O objetivo deste trabalho, portanto, foi observar e constatar os efeitos da mudança da microestrutura em relação às propriedades dureza e condutividade elétrica. / The Cu and its alloys have different applications in the owed modern society the excellent electric properties, thermal conductivity, resistance to the corrosion and other properties. These applications can be in valves, pipes, pots for absorption of solar energy, radiators for automobiles, current driver, electronic driver, thermostats elements and structural parts of nuclear reactors, as, for example, reels for field toroidal for a reactor of nuclear coalition. The alloys used in nuclear reactors, we can highlight Cu-Be, Cu-Sn and Cu-Pt. Ni and Co frequently are added to the Cu alloys so that the solubility is moved for temperatures more elevated with relationship to the binary systems of Cu-Sn and Cu-Pt. The addition of Ni-Pt or Ni-Sn to the Cu in the same or inferior percentages to 1,5% plus thermomechanical treatments changes the properties of the copper. We studied the electric conductivity and hardness Vickers of the Cu-Ni-Pt and Cu-Ni-Sn and compared with the electrolytic Cu. In the proposed flowcharts, breaking of the obtaining of the ingot, we proceeded with thermo mechanical treatments.
158

Avaliação da influência do material obturador na resistência de união de retentor intrarradicular pré-fabricado fixado com resina, em dentes fragilizados, por meio do teste de push-out e MEV / Evaluation of the influence of filling material in the bond strength of a fiber-reinforced post fixed with composite resin in weakened teeth, by push-out test and SEM

Manicardi, Cid Alonso 11 March 2010 (has links)
Normalmente, a restauração de dentes tratados endodonticamente e com extensa destruição corono-radicular é um desafio para o clínico. Devido à facilidade de manipulação, resinas compostas fotoativadas têm se apresentado como boa opção para o reforço intrarradicular destes dentes, antes da fixação de pinos. O objetivo desta pesquisa foi avaliar ex vivo a possível interferência de materiais obturadores no reforço interno de raízes fragilizadas restauradas com pinos de fibra e resina composta, por meio do teste de push-out e posterior análise da interface dentina/resina/cimento/pino em microscopia eletrônica de varredura (MEV). Cinquenta caninos superiores tiveram suas coroas removidas e o remanescente dental padronizado em 17 mm de comprimento. Após o preparo mecânico-químico, os espécimes foram distribuídos em um grupo controle (n=10) (preparo normal para pino e sem obturação prévia do canal) e um grupo experimental (n=40). Os espécimes do grupo experimental tiveram suas raízes fragilizadas com brocas diamantadas, de forma a apresentar folga circunferencial de aproximadamente 1,0 mm entre o pino e a estrutura dentinária circundante. Em seguida, os espécimes fragilizados foram redistribuídos em quatro subgrupos (n=10) de acordo com o tipo de material obturador: (G1) Endofill + guta-percha; (G2) AH Plus + guta-percha; (G3) Epiphany + guta-percha; (G4): Epiphany + Resilon. Após 24 h, todos os canais foram preparados em 12 mm. A dentina intrarradicular foi então condicionada com ácido fosfórico a 32% (15s), lavada com água deionizada (30s) e secada com pontas de papel absorvente. A seguir, fina camada de um sistema adesivo de 3 passos (All Bond 2) foi aplicada à dentina com pontas microbrush. Para o reforço das raízes, cada canal foi preenchido com uma resina dual Bis-Core e um pino de fibra (DT Light Post) inserido em toda a extensão do preparo. A fotopolimerização foi feita através do pino por 20 s, com a ponta do fotopolimerizador disposta perpendicularmente a ele. Decorridas 24 h, os espécimes foram seccionados transversalmente em fatias de 1 mm de espessura. A resistência de união foi avaliada por meio do teste de push-out e as falhas observadas em estereomicroscópio. Os espécimes foram avaliados quali-quantitativamente em MEV quanto à interface adesiva, presença de camada híbrida e densidade dos tags. A análise estatística da resistência de união dos materiais, em MPa, após o teste de push-out, revelou diferença entre o grupo controle (15,4 ± 6,91) e os grupos experimentais (GI - 11,41 ± 4,66; GII - 9,97 ± 3,41; GIII - 10,12 ± 4,18; e GIV - 9,0 ± 4,17) (ANOVA, post-hoc Tukey test, p<0,05). Contudo, não houve diferença entre os terços as regiões analisadas dentro de cada grupo (p>0,05). Houve maior ocorrência de falhas adesivas tanto no grupo controle quanto nos experimentais. Em MEV, a análise quantitativa mostrou formação de camada híbrida, tags de resina e ramificações laterais em todas as regiões analisadas. Dentro das limitações do presente estudo, concluiu-se que a obturação prévia do canal radicular reduziu a resistência de união do material de reforço intrarradicular, sem diferença estatística entre os tipos de cimentos testados. / The restoration of endodontically treated teeth commonly presents a challenge in cases of extensive crown-root destruction. Due to their ease of handling, lightactivated composite resins present a better option for intracanal reinforcement before the use of a fiber posts. The aim of this ex vivo study was to evaluate the influence of filling materials in the root reinforcement of weakened experimentally roots restored with composed resin and quartz fiber post by means of push-out bond strength evaluation and scanning electronic microscopy (SEM) analysis of the dentin/resin/cement/post interface. The crowns of 50 upper maxillary canines were removed and the length of roots standardized in 17 mm. After root canal preparation, the specimens were randomly divide into one control (n=10) (normal post preparation with no previous filling) and one experimental groups (n=40). All specimens in the experimental group had their canals enlarged in such a way as to produce a circumferential space of approximately 1.0 mm between the fiber post and the circumjacent dentine walls, using diamond tips. Then, the specimens of the experimental group were subdivided into four subgroups (n=10), according to the filling materials: (G1) Endofill + gutta-percha; (G2) AH Plus + gutta-percha; (G3) Epiphany + gutta-percha; (G4): Epiphany + Resilon. After 24 h of the root canal filling, the canals of all specimens were prepared into 12 mm. The intracanal dentine was etched with 32% phosphoric acid (15s), rinsed with deionised water (30s) and gently dried with absorbent paper points. A 3-step etch-and-rinse adhesive system (All Bond 2) was applied to the slightly moist dentine with disposable microbrush tips. For root reinforcement, each canal was bulk filled with a translucent composite resin (Bis-Core) and a fiber post (DT Light Post) was centrally inserted into the resin mass along the whole post space extension. Light-curing was performed with a conventional device by placing the tip perpendicularly through the post for 20s. After 24 h of the post cementation, the specimens were sectioned perpendicularly to its long axis in 3 slices, with 1 mm of thickness. The bond strength was performed by the push-out test and, after dislodgments, the failures were observed in the stereomicroscope. The specimens were processed for SEM analysis to observe bonding interface formation, hybrid layer quality and resin tag density using a fourstep scale method. The statistical analysis of the bond strength, in MPa, after the push-out test, indicated difference between control (15,4 ± 6,91) and experimental groups (GI - 11.41 ± 4.66; GII - 9.97 ± 3.41; GIII - 10.12 ± 4.18; e GIV - 9.0 ± 4.17) (ANOVA, post-hoc Tukey test, p<0,05), but not between the evaluated regions (p>0.05). The adhesive failures were frequent in the weakened groups as either in the control group. In SEM, the qualitative analysis showed formation of hybrid layer, resin tags and lateral branches in all the analyzed regions, independently of the group. The quantitative analysis (Kruskal-Wallis test, &alpha;=0.05) indicated that previous root canal filling did not influence in the hybrid layer and resin tags formation. Within the limitations of this study, it may be concluded that previous root canal filling have reduced the bond strength in the weakened group, but the type of sealer did not influence in the results.
159

Ação triboquímica do ciclo mastigatório na resistência ao cisalhamento de resinas compostas / Tribocorrosion effects of masticatory cycle on the composite resins shear bond strength

Contente, Marta Maria Martins Giamatei 07 October 2013 (has links)
Este trabalho avaliou in vitro a ação de estímulos triboquímicos que simulam o ciclo mastigatório na resistência ao cisalhamento de duas resinas compostas Filtek P90®- 3M ESPE (P) e Z250®-3M ESPE (Z) com e sem presença de contaminação salivar, assim como a liberação de íons e a qualidade e a quantidade do desgaste produzido. A amostra foi composta por 12 grupos experimentais (n=5): P1 e Z1, sem contaminação/contra dente decíduo; P2 e Z2, com contaminação/contra dente decíduo; P3 e Z3, sem contaminação/contra dente permanente; P4 e Z4, com contaminação/contra dente permanente; P5 e Z5 sem contaminação (controle); P6 e Z6 com contaminação (controle). Ensaios de tribocorrosão foram efetuados na configuração pino-placa de deslizamento linear alternativo, na presença da solução de saliva artificial, carga de 3N e frequência de 1Hz, totalizando 900 ciclos de desgaste durante 15 minutos. As pistas de desgaste foram caracterizadas por MEV, EDX e XRD e o volume de desgaste por análise da variação de massa. A MEV demonstrou que os grupos Z apresentaram maior quantidade de desgaste quando comparados aos grupos P e que os antagonistas de dente permanente apresentaram maior quantidade de resíduos do material desgastado que os antagonistas em dentes decíduos. A análise por XRD não apresentou variação na caracterização de nenhuma das amostras quando se comparou os espécimes antes e após a realização dos experimentos. Na análise por EDX observou-se picos correspondentes aos elementos Ítrio e Silício para os antagonistas dos grupos P e de Zircônia para os dos grupos Z. Os dados obtidos pelo ensaio de nanoendentação não apresentaram diferença estatisticamente significante para nenhum dos grupos estudados (ANOVA e Teste de Duncan p&le;0,05). Nenhuma diferença estatisticamente significante foi encontrada pelos corpos de prova em resina composta ou antagonistas em nenhum dos grupos estudados quando da análise da variação de massa. Os valores de resistência ao cisalhamento foram: P1 11,20 (±1,44); P2 9,28 (±1,88); P3 8,94 (±1,03); P4 5,76 (±1,47); P5 17,50 (±3,28); P6 15,31 (±1,19); Z1 12,17 (±1,56); Z2 9,60 (±1,56); Z3 10,79 (±3,33); Z4 9,14 (±2,06); Z5 9,77 (±2,27) e Z6 9,22 (±1,98). Os valores de resistência ao cisalhamento foram menores para os grupos P submetidos à contaminação salivar. Na análise de ICP-MS maior liberação de íons Cálcio foi constatada em todos os grupos. A liberação de íons Fosfato foi observada na solução resultante do ensaio tribológico do corpo de prova em resina composta P90 contra antagonista dente permanente. Conclui-se que não há alterações químicas na superfície das resinas após o ensaio mecânico de desgaste e a resina composta P90 apresentou os menores valores de resistência ao cisalhamento em comparação com a resina Z250. A contaminação salivar interferiu negativamente nos valores de resistência ao cisalhamento quando a resina composta P90 foi avaliada. Dente utilizado como contra corpo não teve sua superfície alterada pela incorporação de resíduos de desgaste da resina composta, mantendo o módulo de elasticidade e a nanodureza, sendo que o desgaste ocorreu de forma mais acentuada nas restaurações de resina composta Z250. A liberação de íons Cálcio foi maior que a de íons Fosfato em todas as situações analisadas e a liberação de íons Fosfato foi maior na situação em que o corpo de prova em resina composta P90 foi submetido ao ensaio tribológico contra antagonista dente permanente. O ciclo mastigatório interferiu na resistência ao cisalhamento da resina composta P90. / This study evaluated in vitro the action of tribochemical stimuli simulating the masticatory cycle on the shear bond strength of two composite resins Filtek P90®- 3M ESPE (P) and Z250®-3M ESPE (Z) - with and without salivary contamination, as well as the release of ions and the quality and amount of composite resin/tooth wear. Twelve experimental groups (n=5) were formed: P1 and Z1, without contamination/against primary tooth; P2 and Z2, with contamination/against primary tooth; P3 and Z3, without contamination/against permanent tooth; P4 and Z4, with contamination/against permanent tooth; P5 and Z5, without contamination (control); P6 and Z6, with contamination (control). Tribocorrosion assays were performed using the pin-on-plate configuration under linear reciprocating sliding, in the presence of an artificial saliva solution and under 3 N load and 1 Hz frequency, totalizing 900 wear cycles during 15 minutes. The wear was characterized by SEM, EDX and XRD analyses and the wear volume was determined by mass variation analysis. The SEM analysis showed that the Z groups presented less wear than the P groups, and that the permanent tooth antagonists presented more worn material residues than the primary tooth antagonists. The XRD analysis did not reveal variation in the characterization of any of the samples, comparing the specimens before and after the experiments. The EDX analysis revealed peaks corresponding to the elements yttrium and silicon for the P groups\' antagonists and zircon for the Z groups\' antagonists. Data from the nanoindentation test did not show statistically significant difference for any of the groups (ANOVA and Duncan test p&le;0.05). For the mass variation analysis, no statistically significant difference was found between the composite resin specimens or antagonists in any of the groups. The shear bond strength results were: P1 11.20 (±1.44); P2 9.28 (±1.88); P3 8.94 (±1.03); P4 5.76 (±1.47); P5 17.50 (±3,28); P6 15,31 (±1.19); Z1 12.17 (±1.56); Z2 9,60 (±1.56); Z3 10.79 (±3.33); Z4 9.14 (±2.06); Z5 9.77 (±2.27) and Z6 9.22 (±1.98). The shear bond strength values were lower in the P groups subjected to salivary contamination. The ICP-MS analysis revealed greater calcium ion release in all groups. Regarding phosphate ion, greater release was observed in the solution resulting from the tribological assay when the P90 composite resin specimens were tested against permanent tooth antagonists. In conclusion, there were no chemical alterations on resin surface after the mechanical wear assay and P90 composite resin presented lower shear bond strength values than Z250 composite resin. Salivary contamination affected negatively in the shear bond strength values when P90 resin composite was evaluated. Teeth used as counterbody did not have their surface altered by the incorporation of composite resin wear residues, maintaining the modulus of elasticity and nano-hardness, and the wear was more accentuated in the Z250 composite resin restorations. There was greater release of calcium ions compared with phosphate ions in all analyzed situations and the release of phosphate ions increased when P90 was subjected to tribological assay against a permanent tooth antagonist. Tribochemical stimuli simulating the masticatory cycle interfered with the shear strength of composite resin P90.
160

Caracterização microestrutural do aço ODS Eurofer recozido isotermicamente até 1350oC / Microstructural characterization of ODS Eurofer steel isothermally annealed up to 1350°C

Bredda, Eduardo Henrique 24 March 2015 (has links)
O aço ferrítico-martensítico ODS Eurofer com 9%pCr (ODS - do inglês oxide dispersion strengthened), objeto de estudo dessa dissertação, é um potencial candidato para fins estruturais em reatores de fusão nuclear. Este material foi produzido via metalurgia do pó e consolidado por prensagem isostática. Em seguida sofreu laminação cruzada a quente e revenimento em 750°C por 2h. Esta foi a condição como recebida desse aço, o qual foi cedido pelo KIT (Karlsruher Institut für Technologie - Alemanha). Este aço possui 0,3%p de partículas de ítria (Y2O3) com diâmetro entre 10 e 30 nm. Uma das finalidades dessa dispersão de partículas de óxido é impedir a livre movimentação de contornos de grão no material, de modo a garantir a estabilidade microestrutural do mesmo sob recozimento. O aço ODS Eurofer como recebido foi laminado a frio com reduções de 20, 40, 60 e 80% da espessura e, posteriormente, foi recozido em diversas temperaturas entre 300 e 1350°C por 1h. Como o enfoque desse trabalho é sobre o aço ODS Eurofer recozido em altas temperaturas, para as temperaturas de 1250, 1300 e 1350°C foram feitos recozimentos adicionais (para o material com 80% de redução) variando-se o tempo de recozimento de 1 a 8 h. Para todos os recozimentos, com exceção dos realizados em 1350°C, o resfriamento das amostras se deu ao ar. Para a temperatura de 1350°C isso não foi possível e o resfriamento das amostras se deu no interior do forno. As amostras foram caracterizadas utilizando-se de medidas de dureza, medidas magnéticas e microscopia eletrônica de varredura (MEV). Amostras representativas também foram analisadas utilizando-se de difração de elétrons retroespalhados (EBSD) e espectroscopia por energia dispersiva (EDS). Para recozimentos em temperaturas acima de 800°C seguidos de resfriamento ao ar o material sofreu uma transformação martensítica. Na faixa de temperatura entre 800°C e 1300°C verificou-se um ligeiro decréscimo na dureza do material. Para as amostras com 80% de redução e recozidas em 1250 e 1300°C por diversos tempos até 8 h, seguido de resfriamento ao ar, não ocorreu uma variação significativa tanto nos valores de dureza e de campo coercivo das amostras com o tempo de recozimento. Estes valores se mantiveram em um patamar bem superior ao verificado para as amostras sem recozimento. Para as amostras recozidas em 1350°C, devido às características do resfriamento a microestrutura resultou em grãos ferríticos, aproximadamente equiaxiais e com tamanho de grão médio da ordem de 15 ?m. Observou-se uma notável queda tanto no valor de dureza como de campo coercivo dessas amostras. A observação mais importante nesse caso foi a observação de partículas da ordem de 100 nm ricas em ítrio no interior dos grãos, uma evidência de que ocorre o engrossamento das partículas de ítria nessa temperatura. Em virtude disso, a capacidade dessa dispersão de óxidos em impedir a livre movimentação de contornos de grãos no material fica prejudicada em 1350°C. / The object of this study is Eurofer 9% Cr Oxide Dispersion Strengthened (ODS) steel. This ferritic/martensitic steel is a potential candidate for structural applications in nuclear fusion reactors. It is produced through powder metallurgy and consolidated by hot isostatic pressing. The material undergoes hot cross lamination and is tempered at 760 °C. This was the condition of the steel as received, which was provided by KIT (Karlsruher Institut für Technologie, Germany). This steel contains 0.3 wt% yttria particles (Y2O3) with a diameter in the range 10-30nm. The main purpose of this oxide particle dispersion is to prevent the free movement of the grain boundaries in the material, so as to ensure stability of the microstructure during annealing. The material as received was cold rolled to reduce thickness by 20, 40, 60 and 80%. It was annealed at different temperatures from 300 to 1350 °C for 1 h. The focus of this study is the effects of high temperature annealing on the microstructure of ODS Eurofer. For this purpose, additional heat treatments were carried out on the steel that had been rolled to reduce thickness by 80% at temperatures of 1250, 1300 and 1350 °C. Annealing time varied between 15 min and 8 h. For all annealing conditions, except those carried out at 1350 °C, the samples were air cooled. For the temperature of 1350 °C, this was not possible. These samples were cooled in the oven. The samples were characterized using hardness testing, magnetic testing, and scanning electron microscopy (SEM). Representative samples were also analyzed using electron backscatter diffraction (EBSD) and energy dispersive spectroscopy (EDS). For annealing at temperatures above 800 °C, the material underwent a martensitic transformation after air cooling. Between 800 and 1300 °C, there was a slight decrease in the hardness of the material. For samples with 80% reduction annealed at 1250 and 1300 °C followed by air cooling, annealing time up to 8h didn\'t lead to a significant variation in either the hardness or the coercive field. Both hardness and coercive field of these samples were at a level well above the samples without annealing. For samples annealed at 1350 °C, due to the cooling characteristics of the samples, the microstructure took on a ferritic matrix with equiaxed grains with an average grain size of 15 um. There was a remarkable decrease in hardness and coercive field values of these samples. The most important result in this case was the observation of yttria-rich particles of the order of 100nm inside the grains. This is an evidence of the coarsening of the yttria particles at this temperature. As a result, the capacity of oxide dispersion to prevent the free movement of grain boundaries in the material is impaired at 1350°C.

Page generated in 0.0567 seconds