• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 196
  • 132
  • 132
  • 132
  • 132
  • 132
  • 129
  • 25
  • 14
  • 3
  • 1
  • Tagged with
  • 378
  • 378
  • 378
  • 119
  • 114
  • 112
  • 111
  • 111
  • 104
  • 36
  • 32
  • 31
  • 24
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Strain ultrasound elastography of aneurysm sac content after randomized endoleak embolization with sclerosing and non-sclerosing chitosan-based hydrogels in a preclinical model

Sivakumaran, Lojan 08 1900 (has links)
Mise en contexte : La réparation endovasculaire des anévrismes de l’aorte abdominale est limitée par le développement des endofuites, qui nécessite un suivi à long terme par imagerie. L’élastographie sonore de déformation a été proposée comme méthode complémentaire pour aider à la détection des endofuites et la caractérisation des propriétés mécaniques des anévrismes. On s’intéresse ici également à la possibilité de suivre l’embolisation des endofuites, qui est indiquée dans certains cas mais dont le succès est variable. Un nouvel agent d’embolisation a été récemment créé en combinant un hydrogel de chitosane radio-opaque (CH) et le sclérosant tetradecyl sulfate de sodium (STS), qui s’appelle CH-STS. Le CH-STS démontre des propriétés mécaniques in vitro favorables, mais son comportement in vivo et son effet sur l’évolution du sac par rapport à un agent non-sclérosant pourraient être mieux caractérisés. L’objectif de cette étude était la caractérisation des propriétés mécaniques des composantes des endofuites embolisées avec CH-STS et CH avec élastographie sonore de déformation. Méthodologie : Des anévrismes bilatéraux avec endofuites de type I ont été créés au niveau des artères iliaques communes chez neuf chiens. Chez chaque sujet, une endofuite a été embolisée avec CH, et l’autre, avec CH-STS, d’une façon aléatoire et aveugle. Des images d’échographie duplex et des cinéloops pour élastographie sonore de déformation ont été acquis à 1 semaine, 1 mois, 3 mois et (chez 3 sujets) 6 mois post-embolisation. La tomodensitométrie a été faite à 3 mois et (si pertinente) 6 mois post-embolisation. L’histopathologie a été faite au sacrifice. Les études radiologiques et les données d’histopathologie ont été co-enregistrées pour définir trois régions d’intérêt sur les cinéloops : l’agent d’embolisation (au sacrifice), le thrombus intraluminal (au sacrifice) et le sac anévrismal (pendant chaque suivi). L’élastographie sonore de déformation a été faite avec les segmentations par deux observateurs indépendants. La déformation axiale maximale (DAM) a été le critère d’évaluation principal. Les analyses statistiques ont été faites avec des modèles mixtes linéaires généralisés et des coefficients de corrélations intraclasses (ICCs). Résultats : Des endofuites résiduelles ont été trouvées dans 7/9 (77.8%) et 4/9 (44.4%) des anévrismes embolisés avec CH et CH-STS, respectivement. Le CH-STS a eu une DAM 66 % plus basse (p < 0.001) que le CH. Le thrombus a eu une DAM 37% plus basse (p = 0.010) que le CH et 77% plus élevée (p = 0.079) que le CH-STS. Il n’y avait aucune différence entre les thrombi associés avec les deux traitements. Les sacs anévrismaux embolisés avec CH-STS ont eu une DAM 29% plus basse (p < 0.001) que ceux embolisés avec CH. Des endofuites résiduelles ont été associées avec une DAM du sac anévrismal 53% plus élevée (p < 0.001). Le ICC pour la DAM a été de 0.807 entre les deux segmentations. Conclusion : Le CH-STS confère des valeurs de déformations plus basses aux anévrismes embolisés. Les endofuites persistantes sont associées avec des déformations plus élevées du sac anévrismal. / Background: Endovascular aneurysm repair (EVAR) is the modality of choice for the treatment of abdominal aortic aneurysms (AAAs). EVAR is limited by the development of endoleaks, which necessitate long-term imaging follow-up. Conventional follow-up modalities suffer from unique limitations. Strain ultrasound elastography (SUE) has been recently proposed as an imaging adjunct to detect endoleaks and to characterize aneurysm mechanical properties. Once detected, certain endoleaks may be treated with embolization; however, success is limited. In this context, the embolic agent CH-STS—containing a chitosan hydrogel and the sclerosant sodium tetradecyl sulphate (STS)—was created. CH-STS demonstrates favorable mechanical properties in vitro; however, its behavior in vivo and impact on sac evolution compared to a non-sclerosing chitosan-based embolic agent (CH) merit further characterization. Purpose: To compare the mechanical properties of the constituents of endoleaks embolized with CH and CH-STS—including the agent, the intraluminal thrombus (ILT), and the overall sac—via SUE. Methods: Bilateral common iliac artery aneurysms with type I endoleaks were created in nine dogs. In each animal, one endoleak was randomly embolized with CH, and the other with CH-STS. Duplex ultrasound (DUS) and radiofrequency cine loops were acquired at 1 week, 1 month, 3 months, and—in 3 subjects—6 months post-embolization. Contrast-enhanced CT was performed at 3 months and—where applicable—6 months post-embolization. Histopathological analysis was performed at time of sacrifice. Radiological studies and histopathological slides were co-registered to identify three regions of interest (ROIs) on the cine loops: embolic agent (at sacrifice), ILT (at sacrifice), and aneurysm sac (at all follow-up times). SUE was performed using segmentations from two independent observers on the cine loops. Maximum axial deformation (MAD) was the main outcome. Statistical analysis was performed using general linear mixed models and intraclass correlation coefficients (ICCs). Results: Residual endoleaks were identified in 7/9 (77.8%) and 4/9 (44.4%) aneurysms embolized with CH and CH-STS, respectively. CH-STS had a 66 % lower MAD (p < 0.001) than CH. The ILT had a 37% lower MAD (p = 0.010) than CH and a 77% greater MAD (p = 0.079; trending towards significance) than CH-STS. There was no difference in the ILT between treatment groups. Aneurysm sacs embolized with CH-STS had a 29% lower MAD (p < 0.001) than those with CH. Residual endoleak increased MAD of the aneurysm sac by 53% (p < 0.001), regardless of the agent used. The ICC for MAD was 0.807 between readers’ segmentations. Conclusion: CH-STS confers lower strain values to embolized aneurysms. Persistent endoleaks result are associated with increased sac strain, which may be useful for clinical follow-up.
362

Imagerie par susceptibilité magnétique appliquée aux seins

Rochon-Coutu, Sébastien 12 1900 (has links)
Le manuscrit suivant porte sur le développement d’une méthodologie de cartographie de la susceptibilité magnétique. Cette méthodologie a été appliquée au niveau des seins à des fins de détection de microcalcifications. Afin de valider ces algorithmes, un fantôme numérique ainsi qu’un fantôme réel ont été créés. À l’aide de ces images, les paramètres modifiables de notre méthodologie ont été ajustés. Par la suite, les problèmes reliés à l’imagerie du sein ont été explorés, tel la présence de gras ainsi que la proximité des poumons. Finalement, des images in vivo, acquises à 1.5 et 7.0 Tesla ont été analysées par notre méthodologie. Sur ces images 1.5T, nous avons réussi à observer la présence de microcalcifications. D’un autre côté, les images 7.0T nous ont permis de présenter un meilleur contraste que les images standards de magnitude. / The following manuscript is about the development of a methodology called quantitative susceptibility mapping. This methodology was applied to the breast with the purpose of detecting microcalcifications. To validate these algorithms, a digital phantom and a water phantom were created. Using these images, adjustable parameters were adjusted on our methodology. Thereafter, problems related to breast imaging, like the presence of fat and the proximity of the lungs, were explored. Finally, in vivo images, acquired at 1.5 and 7.0 Tesla were analyzed by our methodology. On these 1.5T images, we successfully observed the presence of microcalcifications. On the other hand, the 7.0T images allowed us to provide a better contrast than the standard magnitude images.
363

Enjeux éthiques en radiologie diagnostique : comment la bioéthique peut-elle contribuer à une meilleure radioprotection du patient?

Doudenkova, Victoria 06 1900 (has links)
Bien que les technologies d’imagerie soient un acquis réel de la médecine moderne, leur introduction ne semble pas avoir été précédée d’une démarche réflexive suffisante qui aurait permis d’anticiper les multiples enjeux que rencontre la pratique radiologique actuelle. En effet, à force de se focaliser sur les acquis techniques et scientifiques, le cadre de radioprotection en place semble ne pas avoir suffisamment considéré l’apport essentiel que représente la connaissance des aspects sociaux, éthiques et humains que peuvent amener des domaines comme la bioéthique. Cette insuffisance fait en sorte que l’on se retrouve aujourd’hui face à des enjeux importants relatifs à la radioprotection du patient comme la surutilisation des examens radiologiques ou encore le manque d’information des acteurs du milieu face aux risques des rayonnements. Après un état des lieux des enjeux éthiques en radiologie diagnostique ayant un impact sur la radioprotection médicale des patients, un enjeu majeur de la pratique actuelle, qui est la justification inadéquate des prescriptions d’examens radiologiques, sera analysé selon une approche par principes. De cet exercice, visant à démontrer comment l’éthique peut concrètement contribuer à la radioprotection, découle l’impératif d’une vision nouvelle et globale permettant de proposer des pistes de solution aux controverses liées à l’utilisation actuelle de l’imagerie. Dans une perspective de santé des populations, il est important de contribuer à la diminution de la banalisation du recours au rayonnement ionisant dans la pratique médicale diagnostique en alliant bioéthique et radioprotection. Ce projet de recherche se veut être une étape limitée, mais nécessaire dans l’établissement de ce dialogue interdisciplinaire. / While imaging technologies represent a real achievement for modern medicine, their introduction seems not to have been preceded by a sufficiently reflective process that would have anticipated the multiple challenges arising in current radiological practice. In focusing on the technical and scientific achievements, the actual radiation protection framework fails to consider sufficiently the essential contribution brought by social, ethical and human dimensions of disciplines such as bioethics. This failure means that today we find ourselves faced with major issues related to patient radiation protection, such as overuse of radiological examinations or medical personnel’s lack of information about the risks of radiation. Following an overview of ethical issues in diagnostic radiology affecting medical radiation protection of patients, a major issue in current practice – i.e., the inadequate justification of radiological examination prescriptions – will be analyzed using a principle-based approach. From this exercise, which aims to demonstrate how ethics can contribute concretely to radiation protection, a need arises for a new and comprehensive vision leading to solutions for controversies related to the current use of medical imaging. In a population health perspective, it is important to contribute to the reduction of the trivialization of the use of ionizing radiation in diagnostic medical practice by combining both bioethics and radiation protection. This research project aims to be a modest but necessary first step in the establishment of such an interdisciplinary dialogue.
364

Semiautomated 3D liver segmentation using computed tomography and magnetic resonance imaging

Gotra, Akshat 08 1900 (has links)
Le foie est un organe vital ayant une capacité de régénération exceptionnelle et un rôle crucial dans le fonctionnement de l’organisme. L’évaluation du volume du foie est un outil important pouvant être utilisé comme marqueur biologique de sévérité de maladies hépatiques. La volumétrie du foie est indiquée avant les hépatectomies majeures, l’embolisation de la veine porte et la transplantation. La méthode la plus répandue sur la base d'examens de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM) consiste à délimiter le contour du foie sur plusieurs coupes consécutives, un processus appelé la «segmentation». Nous présentons la conception et la stratégie de validation pour une méthode de segmentation semi-automatisée développée à notre institution. Notre méthode représente une approche basée sur un modèle utilisant l’interpolation variationnelle de forme ainsi que l’optimisation de maillages de Laplace. La méthode a été conçue afin d’être compatible avec la TDM ainsi que l' IRM. Nous avons évalué la répétabilité, la fiabilité ainsi que l’efficacité de notre méthode semi-automatisée de segmentation avec deux études transversales conçues rétrospectivement. Les résultats de nos études de validation suggèrent que la méthode de segmentation confère une fiabilité et répétabilité comparables à la segmentation manuelle. De plus, cette méthode diminue de façon significative le temps d’interaction, la rendant ainsi adaptée à la pratique clinique courante. D’autres études pourraient incorporer la volumétrie afin de déterminer des marqueurs biologiques de maladie hépatique basés sur le volume tels que la présence de stéatose, de fer, ou encore la mesure de fibrose par unité de volume. / The liver is a vital abdominal organ known for its remarkable regenerative capacity and fundamental role in organism viability. Assessment of liver volume is an important tool which physicians use as a biomarker of disease severity. Liver volumetry is clinically indicated prior to major hepatectomy, portal vein embolization and transplantation. The most popular method to determine liver volume from computed tomography (CT) and magnetic resonance imaging (MRI) examinations involves contouring the liver on consecutive imaging slices, a process called “segmentation”. Segmentation can be performed either manually or in an automated fashion. We present the design concept and validation strategy for an innovative semiautomated liver segmentation method developed at our institution. Our method represents a model-based approach using variational shape interpolation and Laplacian mesh optimization techniques. It is independent of training data, requires limited user interactions and is robust to a variety of pathological cases. Further, it was designed for compatibility with both CT and MRI examinations. We evaluated the repeatability, agreement and efficiency of our semiautomated method in two retrospective cross-sectional studies. The results of our validation studies suggest that semiautomated liver segmentation can provide strong agreement and repeatability when compared to manual segmentation. Further, segmentation automation significantly shortens interaction time, thus making it suitable for daily clinical practice. Future studies may incorporate liver volumetry to determine volume-averaged biomarkers of liver disease, such as such as fat, iron or fibrosis measurements per unit volume. Segmental volumetry could also be assessed based on subsegmentation of vascular anatomy.
365

Ultrafast Echocardiography

Posada, Daniel 08 1900 (has links)
Grâce à son accessibilité, sa polyvalence et sa sécurité, l'échocardiographie est devenue la technique d'imagerie la plus utilisée pour évaluer la fonction cardiaque. Au vu du succès de l'échographie ultrarapide par ondes planes des techniques similaires pour augmenter la résolution temporelle en échocardiographie ont été mise en oeuvre. L’augmentation de la résolution temporelle de l’échographie cardiaque au-delà des valeurs actuellement atteignables (~ 60 à 80 images par secondes), pourrait être utilisé pour améliorer d’autres caractéristiques de l'échocardiographie, comme par exemple élargir la plage de vitesses détectables en imagerie Doppler couleur limitées par la valeur de Nyquist. Nous avons étudié l'échocardiographie ultrarapide en utilisant des fronts d’ondes ultrasonores divergentes. La résolution temporelle atteinte par la méthode d'ondes divergentes a permis d’améliorer les capacités des modes d’échocardiographie en mode B et en Doppler couleur. La résolution temporelle de la méthode mode B a été augmentée jusqu'à 633 images par secondes, tout en gardant une qualité d'image comparable à celle de la méthode d’échocardiographie conventionnelle. La vitesse de Nyquist de la méthode Doppler couleur a été multipliée jusqu'à 6 fois au delà de la limite conventionnelle en utilisant une technique inspirée de l’imagerie radar; l’implémentation de cette méthode n’aurait pas été possible sans l’utilisation de fronts d’ondes divergentes. Les performances avantageuses de la méthode d'échocardiographie ultrarapide sont supportées par plusieurs résultats in vitro et in vivo inclus dans ce manuscrit. / Because of its low cost, versatility and safety, echocardiography has become the most common imaging technique to assess the cardiac function. The recent success of ultrafast ultrasound plane wave imaging has prompted the implementation of similar approaches to enhance the echocardiography temporal resolution. The ability to enhance the echocardiography frame rate beyond conventional values (~60 to 80 fps) would positively impact other echocardiography features, e.g. broaden the color Doppler unambiguous velocity range. We investigated the ultrafast echocardiography imaging approach using ultrasound diverging waves. The high frame rate offered by the diverging wave method was used to enhance the capabilities of both B-mode and color Doppler echocardiography. The B-mode temporal resolution was increased to 633 fps whilst the image quality was kept almost unchanged with reference to the conventional echocardiography technique. The color Doppler Nyquist velocity range was extended to up to 6 times the conventional limit using a weather radar imaging approach; such an approach could not have been implemented without using the ultrafast diverging wave imaging technique. The advantageous performance of the ultrafast diverging wave echocardiography approach is supported by multiple in vitro and in vivo results included in this manuscript.
366

Réduction des artéfacts de tuteur coronarien au moyen d’un algorithme de reconstruction avec renforcement des bords : étude prospective transversale en tomodensitométrie 256 coupes

Chartrand-Lefebvre, Carl 08 1900 (has links)
Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard. / Metallic artifacts can result in an artificial thickening of the coronary stent wall which can significantly impair computed tomography (CT) imaging in patients with coronary stents. The purpose of this study is to assess the in vivo visualization of coronary stent wall and lumen with an edge-enhancing CT reconstruction kernel, as compared to a standard kernel. This is a prospective cross-sectional study of 24 consecutive patients with 71 coronary stents, using a repeated measure design and blinded observers, approved by the Local Institutional Review Board. 256-slice CT angiography was used, as well as standard and edge-enhancing reconstruction kernels. Stent wall thickness was measured with orthogonal and circumference methods, averaging wall thickness from stent diameter and circumference measurements, respectively. Stent image quality was assessed on an ordinal scale. Statistical analysis used linear and proportional odds models. Stent wall thickness was inferior using the edge-enhancing kernel compared to the standard kernel, either with the orthogonal (0.97±0.02 versus 1.09±0.03 mm, respectively; p<0.001) or circumference method (1.13±0.02 versus 1.21±0.02 mm, respectively; p<0.001). The edge-enhancing kernel generated less overestimation from nominal thickness compared to the standard kernel, both with orthogonal (0.89±0.19 versus 1.00±0.26 mm, respectively; p<0.001) and circumference (1.06±0.26 versus 1.13±0.31 mm, respectively; p=0.005) methods. The average decrease in stent wall thickness overestimation with an edge-enhancing kernel was 6%. Image quality scores were higher with the edge-enhancing kernel (odds ratio 3.71, 95% CI 2.33–5.92; p<0.001). In conclusion, the edge-enhancing CT reconstruction kernel generated thinner stent walls, less overestimation from nominal thickness, and better image quality scores than the standard kernel.
367

Validation de la reproductibilité d’outils de mesure de la fraction d’éjection du ventricule gauche en médecine nucléaire

Arsenault, Frédéric 05 1900 (has links)
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle. / Left ventricular ejection fraction is an excellent indicator of cardiac function. Many invasive and non-invasive techniques can be used for its assessment: angiography, echocardiography, cardiac MRI, computed tomography of the heart, multigated radionuclide angiography and myocardial perfusion imaging. More than 40 years of scientific publication praise the multigated radionuclide angiography for its execution speed, its availability, its low cost and intrarater and interrater reproducibility. The left ventricular ejection fraction was calculated twice for 47 patients, using two raw data acquisitions, two technologists and three software platforms: one fully manual, one semi-automatic and one fully automatic. In general, the automatic and semi-automatic methods showed greater reproducibility, a smaller standard error of measurement and minimal detectable change than the manual method, whereas the manual method systematically gave a significantly lower quality of result. It was the only technique that showed significant intrarater difference, and its standard error of measurement and minimal detectable change were 40% to 50% higher than those of automatic and semi-automatic methods. Even though all three techniques are all excellent and reliable options, reliability coefficient estimations were superior using automatic and semi-automatic methods as compared to the manual method.
368

Assessing microvascular function with breathing maneuvers : an oxygenation-sensitive CMR study

Fischer, Kady 06 1900 (has links)
Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale. / This project encompasses five studies, which focus on developing a new cardiovascular diagnostic approach for assessing myocardial oxygenation and microvascular function. In combination with oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging, breathing maneuvers and altered arterial blood gases can be used as a non-invasive method for inducing a vasoactive response to test the oxygenation reserve, a key measurement in vascular function. The number of prescribed cardiac diagnostic tests and interventions is rapidly growing. In particular, imaging and other non-invasive tests are frequently performed prior to invasive procedures. One of the most common uses of cardiac imaging is for the diagnosis of significant coronary artery stenosis, a critical cost factor in today’s health care system. Non-invasive imaging techniques provide the most reliable information for the presence and location of perfusion or oxygenation deficits in patients with symptoms suggestive of myocardial ischemia, yet many current techniques suffer from the need for radiation, contrast agents or tracers, and pharmacological or physical stress protocols. CMR imaging can identify significant coronary artery stenosis without radiation and new trends in CMR research aim to develop diagnostic techniques that do not require any pharmacological stressors or contrast agents. For this project, the primary aim was to develop and test a new diagnostic technique to assess coronary vascular function using OS-CMR in combination with breathing maneuvers as the vasoactive stimulus. Secondary aims then used OS-CMR to assess myocardial oxygenation and the coronary response in the presence of altered arterial blood gases. An animal model was used to validate the vascular response to breathing maneuvers before translating the technique to human subjects into both healthy volunteers, and a patient population with cardiac disease. In the animal models, breathing maneuvers could induce a significant change in invasively measured coronary blood flow and it was demonstrated that in the presence of a haemodynamically significant coronary stenosis, OS-CMR could detect a myocardial oxygen deficit. This technique was then applied in a human model, with healthy participants. In a direct comparison to the infusion of the coronary vasodilator adenosine, which is considered a standard agent for inducing vasodilation in cardiac imaging, breathing maneuvers induced a stronger response in oxygenation of healthy myocardium. The final study then implemented the breathing maneuvers in a patient population with coronary artery disease; in which myocardium compromised by a coronary stenosis had a compromised oxygenation response. Furthermore, the observed effects of arterial blood gases on myocardial oxygenation were assessed. This demonstrated that the coronary response to breath-hold stimuli is attenuated during hyperoxia, and this causes an overall reduction in coronary blood flow, and consequently an oxygenation deficit in a coronary stenosis animal model when supplemental oxygen is provided. In conclusion, this work has improved our understanding of potential new diagnostic techniques for cardiovascular imaging. In particular, it demonstrated that combining breathing maneuvers with oxygenation-sensitive CMR can provide a non-invasive and cost-effective method for assessing global and regional coronary vascular function.
369

Évaluation par IRM 3T, par échographie et par microscopie du cartilage épiphysaire de poulains de 0-6 mois d’âge : mieux comprendre et diagnostiquer l’ostéochondrose

Martel, Gabrielle 05 1900 (has links)
No description available.
370

Imagerie par susceptibilité magnétique appliquée aux seins

Rochon-Coutu, Sébastien 12 1900 (has links)
Le manuscrit suivant porte sur le développement d’une méthodologie de cartographie de la susceptibilité magnétique. Cette méthodologie a été appliquée au niveau des seins à des fins de détection de microcalcifications. Afin de valider ces algorithmes, un fantôme numérique ainsi qu’un fantôme réel ont été créés. À l’aide de ces images, les paramètres modifiables de notre méthodologie ont été ajustés. Par la suite, les problèmes reliés à l’imagerie du sein ont été explorés, tel la présence de gras ainsi que la proximité des poumons. Finalement, des images in vivo, acquises à 1.5 et 7.0 Tesla ont été analysées par notre méthodologie. Sur ces images 1.5T, nous avons réussi à observer la présence de microcalcifications. D’un autre côté, les images 7.0T nous ont permis de présenter un meilleur contraste que les images standards de magnitude. / The following manuscript is about the development of a methodology called quantitative susceptibility mapping. This methodology was applied to the breast with the purpose of detecting microcalcifications. To validate these algorithms, a digital phantom and a water phantom were created. Using these images, adjustable parameters were adjusted on our methodology. Thereafter, problems related to breast imaging, like the presence of fat and the proximity of the lungs, were explored. Finally, in vivo images, acquired at 1.5 and 7.0 Tesla were analyzed by our methodology. On these 1.5T images, we successfully observed the presence of microcalcifications. On the other hand, the 7.0T images allowed us to provide a better contrast than the standard magnitude images.

Page generated in 0.0646 seconds