• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 508
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • Tagged with
  • 533
  • 408
  • 163
  • 159
  • 113
  • 73
  • 67
  • 65
  • 58
  • 58
  • 55
  • 54
  • 51
  • 51
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo comparativo de técnicas de medição e aquisição de sinais de transdutores piezelétricos para detecção de dano baseada na impedância eletromecânica /

Budoya, Danilo Ecidir. January 2018 (has links)
Orientador: Fabricio Guimarães Baptista / Banca: Fernando de Souza Campos / Banca: Mário Anderson de Oliveira / Resumo: Sistemas de monitoramento de integridade estrutural (SHM - Structural Health Monitoring) são científica e economicamente relevantes como métodos de detecção de danos estruturais em diversos tipos de estruturas, aumentando assim a segurança e reduzindo os custos de manutenção. Entre os vários princípios de detecção de danos, o método da impedância eletromecânica (E/M) baseia-se na medição da impedância elétrica do transdutor piezelétrico fixado à estrutura monitorada. Aqui, a exatidão e precisão do sistema de medição são fundamentais para o diagnóstico correto da estrutura. Portanto, essa dissertação apresenta uma análise comparativa de duas técnicas de medição de impedância para detecção de danos que são tipicamente utilizadas em analisadores de impedância comerciais e em outros sistemas de medição alternativos: medições em estado transitório utilizando um sinal de excitação de varredura e medições em estado estacionário utilizando um sinal senoidal puro para cada frequência de excitação. Os testes foram realizados com cargas resistivas e capacitivas de valores nominais 100 Ω e 10 nF, respectivamente, e com um transdutor piezelétrico fixado em uma barra de alumínio que representa uma estrutura monitorada. As duas técnicas foram comparadas com base na exatidão, precisão, sensibilidade à danos e tempo necessário para as medições. Os resultados destacam as características importantes de cada técnica, as quais devem ser consideradas para o desenvolvimento de sistemas de SHM basea... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Structural health monitoring (SHM) systems are scientifically and economically relevant as methods of detecting structural damage to various types of structures, thus increasing safety and reducing maintenance costs. Among the various principles of damage detection, the electromechanical impedance (EMI) method is based on the electrical impedance measurement of piezoelectric transducers attached to the monitored structure. Here, the accuracy and precision of the measurement system are fundamental for the correct diagnosis of the structure. Therefore, this dissertation presents a comparative analysis of two impedance measurement techniques for damage detection that are typically used in commercial impedance analyzers and other alternative measurement systems: transient-state measurements using a sweep excitation signal and steady-state measurements using a pure sinusoidal signal for each excitation frequency. Tests were performed with resistive and capacitive loads with nominal values of 100 Ω e 10 nF, respectively, and a piezoelectric transducer fixed to an aluminum bar representing a monitored structure. The two techniques were compared based on the accuracy, precision, sensibility to damage and time required for the measurements. The results highlight the important features of each technique, which should be considered for the development of impedance-based SHM systems and the correct diagnosis of monitored structures. / Mestre
62

Avaliação da ventilação mecânica controlada a pressão utilizando-se a técnica de tomografia por impedância elétrica durante anestesia geral em cães / Evaluation of pressure-controlled ventilation using the technique of electrical impedance tomography during general anesthesia in dogs

Kamakura, Tatiana Paula Alvarenga de Carvalho 13 December 2013 (has links)
A hipoventilação secundária ao procedimento anestésico é comum na prática anestésica, e, sendo assim, o emprego de técnicas de ventilação mecânica é adotado como forma de minimizar e/ou evitar os efeitos deletérios da hipoventilação. Porém, o uso de ventiladores mecânicos não é isento de risco, e atelectasias podem se formar mesmo quando são utilizados. Para análise em tempo real do pulmão, a técnica de tomografia por impedância elétrica vem sendo empregada em conjunto com outros meios de monitoração, tendo se demonstrado um meio útil de avaliação da ventilação pulmonar de maneira não invasiva, passível de ser utilizada à beira do leito e sem emissão de radiação. Estudos utilizando o tomógrafo de impedância elétrica em cães são escassos. O objetivo desse trabalho foi avaliar a ventilação de cães submetidos à anestesia inalatória e à ventilação mecânica utilizando a técnica de tomografia por impedância elétrica. Foram utilizados onze cães com peso superior a 16 kg e classificados como baixo risco anestésico (ASA I ou II). Os animais receberam acepromazina e meperidina como medicação pré-anestésica, propofol como indutor e isofluorano na manutenção da anestesia. Foram mantidos em ventilação mecânica controlada a pressão, com FiO2 de 0,6 e pressão de pico de 10 cmH2O durante os primeiros 90 minutos de anestesia. Foram então realizadas manobras de recrutamento alveolar e instituição de pressão positiva ao final da expiração (PEEP) de 5 cmH2O, e os animais foram avaliados por mais 35 minutos. Os parâmetros foram avaliados 30, 60 e 90 minutos após a indução da anestesia e 5 e 35 minutos após o recrutamento e instituição da PEEP. Apesar de não ter havido diferença estatisticamente significativa nos parâmetros de oxigenação e distribuição da ventilação, foi visível a melhora clínica e nas curvas de oxigenação e impedância. As curvas de impedância geradas a partir dos dados obtidos pelo tomógrafo de impedância elétrica acompanharam as curvas de melhora na oxigenação. O fato de, no estudo, terem sido utilizados animais hígidos e submetidos à ventilação mecânica e FiO2 de 0,6 desde o início pode ter contribuído para não ter havido melhora estatisticamente significativa, embora clinicamente visível. As manobras de recrutamento utilizadas também foram conservadoras em comparação aos outros trabalhos realizados. Infere-se que, se utilizássemos animais doentes e com FiO2 de 1, poderíamos ter obtido um grau maior de atelectasias nos primeiros 90 minutos de anestesia e/ou, se tivéssemos utilizado manobras de recrutamento menos conservadoras, poderíamos ter obtidos melhora estatisticamente significativa após as manobras e instituição da PEEP. A tomografia de impedância elétrica parece ser um bom meio de monitoração do pulmão em tempo real em cães submetidos à anestesia inalatória. / Hypoventilation secondary to anesthesia is common and, therefore, the use of mechanical ventilation techniques is adopted in order to minimize and/or prevent the deleterious effects of hypoventilation. However, the use of mechanical ventilators has risks, and atelectasis can develop even when they are used. For real-time analysis of the lung, the technique of electrical impedance tomography has been used in conjunction with other means of monitoring, having demonstrated to be useful for assessing pulmonary ventilation in a noninvasively way, and also can be used at the bedside and without radiation emission. There are not many studies using electrical impedance tomography in dogs. The aim of this study was to evaluate the ventilation of dogs subjected to inhalation anesthesia and mechanical ventilation using the technique of electrical impedance tomography. We used eleven dogs weighing more than 16 kg and classified as low anesthetic risk (ASA I or II). The animals were premedicated with acepromazine and meperidine, anesthesia was induced with propofol and maintained with isoflurane. Ventilation was then instituted with FiO2 of 0.6 and peak pressure of 10 cm H2O during the first 90 minutes of anesthesia. Alveolar recruitment maneuvers were realized and pressure positive end- expiratory pressure (PEEP) of 5 cmH2O was initiated. The animals were evaluated for more 35 minutes then. The parameters were measured at 30, 60 and 90 minutes after induction of anesthesia and 5 and 35 minutes after recruitment. Although there was no statistically significant difference in the parameters of oxygenation and ventilation distribution, clinical improvement was visible as was the oxygenation and impedance curves. The impedance curves generated from the data obtained with the electrical impedance tomograph followed the improvement in oxygenation curves. The fact that in this study we used healthy animals undergoing mechanical ventilation with FiO2 of 0.6 right from the beginning, may have contributed to no improvement statistically significant but clinically visible. Recruitment maneuvers used were also conservative in comparison to other papers. We think that, if we used animals and patients with FiO2 of 1, we could have obtained a higher degree of atelectasis in the first 90 minutes of anesthesia and/or, if we had used less conservative recruitment maneuvers, we could have obtained statistically significant improvement after maneuvers and institution of PEEP. The electrical impedance tomography seems to be a good means of real time monitoring the lung of dogs undergoing inhalation anesthesia.
63

Comparação da pressão arterial, aferida por mapa, após sessão de hemodiálise, em pacientes submetidos à avaliação clínica ou bioimpedância, para determinação de peso seco

Lara, Darlan Martins January 2010 (has links)
Introdução: Há uma forte conexão entre doença renal e risco para doença cardiovascular. A hipertensão arterial é o fator mais importante associado com ambas as condições. Em pacientes em hemodiálise, o primeiro passo na obtenção de um melhor controle da pressão arterial é estabelecer o melhor peso seco. Tradicionalmente, o peso seco é definido a partir da avaliação clínica, por tentativa e erro. A bioimpedância pode avaliar a água corporal total e ajudar no ajuste do peso seco. O objetivo foi avaliar a redução do peso seco e da pressão arterial a partir de duas estratégias de determinação do peso ideal em pacientes renais crônicos, em programa hemodialiítico. Métodos: Trata-se de um ensaio clínico, no qual 70 pacientes, com idades entre 23 e 79 anos, foram randomizados para o grupo de avaliação clínica somente (n=36) ou para avaliação clínica mais bioimpedância elétrical tetramodal (n=34). Medidas de pressão arterial, por meio de monitorização ambulatorial da pressão arterial de 24 horas (MAPA-24h), e a ocorrência de sintomas intradialíticos foram obtidas antes e duas semanas após a intervenção. Os grupos foram comparados por intermédio de teste χ 2, Teste t ou Mann-Whitnney. A interação tempo-grupo das medidas pressóricas foram analisadas por meio de teste de variança para medidas repetidas (MANOVA). Resultados: As características dos grupos foram semelhantes. A redução nas pressões arteriais, sistólica e diastólica, não diferiu entre os grupos de intervenção. Observou-se uma maior redução de peso nos pacientes do grupo da bioimpedância. Houve uma diferença significativa (P=0,008) na redução do peso seco no grupo da bioimpedância (mediana=0,5kg, percentil 25-75=0,0 a 1,0Kg) em relação ao grupo da avaliação clínica (mediana=0,0kg, percentil 25-75=0,0 a 0,5Kg). A maior redução de peso no grupo de bioimpedância não implicou em aumento das complicações intradialíticas. Encontrou-se, também, que a proporção de pacientes que não tiveram seu peso reduzido foi significativamente diferente (P=0,009), sendo 69,4% (25 de 36) no grupo da avaliação clínica contra 38,2% (13 de 34) no grupo de bioimpedância. Conclusão: A biompedância elétrica tetramodal não resultou em uma variação significativa na pressão sistólica e diástolica, aferida por MAPA-24h, num acompanhamento de duas semanas. Seu benefício na redução da pressão arterial deve ser melhor avaliado em estudo com um período de seguimento mais longo. Em relação à avaliação do peso seco, a BIE mostrou-se um método útil, por permitir uma maior redução de peso, sem aumentar as intercorrências intradialíticas. Sua aplicação, complementar à avaliação clínica, pode somar as qualidades dos dois métodos, contribuindo para o manejo clinico, bem-estar e qualidade de vida do doente renal crônico em tratamento dialítico.
64

Análise da impedância acústica na gasolina / Acoustic impedance analysis of gasoline

Karina Zoboli Buttarello 03 October 2003 (has links)
Este trabalho analisa a qualidade dos combustíveis derivados de petróleo através de suas propriedades acústicas, visando assim um monitoramento contínuo e instantâneo. Analisa a variação da impedância acústica da gasolina com acréscimo de vários componentes como: tolueno, óleo diesel, querosene e álcool anidro. Os resultados obtidos mostram uma variação significativa embora não linear da impedância acústica nos combustíveis derivados de petróleo com acréscimo de tais substâncias. / This work is related with research project focused on the development of low cost and robust quality monitoring equipment and methods, suitable for application in the production of petrochemical compounds. The main objective of this work is to assess the quality of automotive gasoline through the analysis of its acoustic properties. More specifically, pure gasoline\'s acoustic impedance (defined as the product between its density and the velocity of propagation of an acoustic wave) is analyzed with respect to the addition of toluene, kerosene, ethanol and diesel fuel. Results show that the acoustic impedance is sensitive to the addition of such components, although this relation may be non-linear in some cases.
65

Análise da impedância acústica na gasolina / Acoustic impedance analysis of gasoline

Buttarello, Karina Zoboli 03 October 2003 (has links)
Este trabalho analisa a qualidade dos combustíveis derivados de petróleo através de suas propriedades acústicas, visando assim um monitoramento contínuo e instantâneo. Analisa a variação da impedância acústica da gasolina com acréscimo de vários componentes como: tolueno, óleo diesel, querosene e álcool anidro. Os resultados obtidos mostram uma variação significativa embora não linear da impedância acústica nos combustíveis derivados de petróleo com acréscimo de tais substâncias. / This work is related with research project focused on the development of low cost and robust quality monitoring equipment and methods, suitable for application in the production of petrochemical compounds. The main objective of this work is to assess the quality of automotive gasoline through the analysis of its acoustic properties. More specifically, pure gasoline\'s acoustic impedance (defined as the product between its density and the velocity of propagation of an acoustic wave) is analyzed with respect to the addition of toluene, kerosene, ethanol and diesel fuel. Results show that the acoustic impedance is sensitive to the addition of such components, although this relation may be non-linear in some cases.
66

Caracterização do reservatório Marlim por inversão acústica / Marlim reservoir characterization by acoustic impendance

Tatiane Moura do Nascimento 30 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Exploracionistas tem grande interesse em sistemas turbidíticos, pois em geral estes compõem prolíficos plays exploratórios. No entanto, estes potenciais reservatórios se encontram muitas vezes perto ou abaixo de resolução sísmica. Dessa forma, no processo de inversão, é importante integrar os dados sísmicos com qualidade de resolução obtida a partir do seu pré-condicionamento, para que o resultado final possua características detalhadas das camadas. O pré-condicionamento possibilita melhora na resolução dos dados sísmicos, através da atenuação dos ruídos aleatórios. Como objetivo final, foi realizada a inversão acústica em dados sísmicos post stack, migrados em tempo, a um sistema de turbiditos na Bacia de Campos. O principal objetivo da inversão sísmica é transformar o dado de reflexão em propriedades petrofísicas quantitativas. A inversão para impedância acústica é comumente utilizada para predição de porosidade. O fluxo de trabalho proposto foi dividido em cinco estágios principais: pré-condicionamento sísmico do dado 3D, correlação poço-sísmica, construção do modelo de baixa frequência, inversão do dado, e estimativa da porosidade. Os resultados mostraram que o cubo de impedância acústica invertido possui resolução muito superior quando comparado com o dado em amplitude sísmica, possibilitando melhor visualização das feições geológicas do Campo de Marlim. Além de suas limitações, como desconsiderando os efeitos das variações de fluido e variações litológicas complexas sobre a relação porosidade/impedância, o método fornece uma ferramenta confiável para exploração sísmica. Detalhes mais precisos das propriedades petrofísicas podem ser obtidos através de métodos de inversão mais sofisticados, a partir de dados pre stack. / Exploracionists has great interest in turbidite systems, since these generally comprise prolific exploration plays. However, these potential reservoirs are often near or below seismic resolution. Thus, the inversion process is important to integrate the seismic data quality of the resolution obtained from its preconditioning, so that the end result has detailed characteristics of the layers. The preconditioning enables improved resolution of seismic data, through mitigation of random noise. As the final goal, the inversion was performed acoustic post stack seismic data, migrated time, to a system of turbidites in Campos Basin. The main purpose of seismic inversion is to transform the given reflection in quantitative petrophysical properties. The inversion for acoustic impedance is commonly used to predict porosity. The flow of the proposed work was divided into five main stages: pre-conditioning the seismic 3D data, well-tie correlation, construction of the model of low frequency, inversion of data and estimation of porosity. The results showed that the inverted acoustic impedance cube has much higher resolution compared to the seismic amplitude data, allowing greater visualization of geological features in the Marlim Field. Besides its limitations as ignoring the effects of changing the fluid and complex lithological variations on the relationship porosity / impedance, the method provides a reliable tool for seismic exploration. More precise details of petrophysical properties can be obtainedthrough inversion methods starting from sophisticated pre-stack data.
67

Um novo filtro de microondas com dupla banda passante utilizando ressoadores miniaturizados / A new dual band microwave filter using miniaturized resonators

Alves, Célio Ramos 08 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2007. / Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2008-11-25T18:34:59Z No. of bitstreams: 1 Dissertacao_2007_CelioRamosAlves.pdf: 1536344 bytes, checksum: 95932402c6c4ffa379c35a463a9bc981 (MD5) / Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-02-09T15:23:18Z (GMT) No. of bitstreams: 1 Dissertacao_2007_CelioRamosAlves.pdf: 1536344 bytes, checksum: 95932402c6c4ffa379c35a463a9bc981 (MD5) / Made available in DSpace on 2009-02-09T15:23:19Z (GMT). No. of bitstreams: 1 Dissertacao_2007_CelioRamosAlves.pdf: 1536344 bytes, checksum: 95932402c6c4ffa379c35a463a9bc981 (MD5) / Desenvolvimentos recentes nos sistemas de comunicação trouxeram novos desafios no projeto de circuitos de RF. Parâmetros como miniaturização, leveza, baixo custo e facilidade de fabricação são demandados cada vez mais. Filtros com característica de dupla banda passante usando ressoadores de impedância degrau (SIR) são uma boa opção. Nesta pesquisa um novo tipo de filtro planar em microfita usando ressoadores SIR acoplados é investigado. Além disso, um ressoador de laço aberto acoplado internamente é inserido para melhorar a resposta do filtro. Os filtros são simulados e fabricados, comparando-se as respostas. ___________________________________________________________________________________________ ABSTRACT / Recent development in present ommunications systems has created challenges in design of RF circuits. Parameters as small size, reduced weight, low cost and easy fabrication are every day more demanded. Dual band filters using stepped impedance resonator (SIR) are good option. In this research a new type of planar microwave filter using coupled microstrip SIR resonators is proposed. Furthermore, an openloop resonator is coupled in order to improvement filter response. Measured results are compared with the computed responses.
68

Fibronasofaringolaringoscopia flexível no diagnóstico de hiperplasia adenoideana e na determinação de comprometimento de toro tubário pelas adenóides

kindermann, Christiane Aparecida January 2006 (has links)
A hiperplasia adenoideana é considerada uma das causas mais comum de obstrução nasal em crianças. Ela está diretamente relacionada com manifestações locais como rinossinusites, otites e doenças sistêmicas. Embora os mecanismos pelos quais o aumento adenoideano possa contribuir nestas doenças crônicas ainda permaneçam controversos. Descobrir a correta etiologia da obstrução nasal em crianças é prática quase diária em clínicas de otorrinolaringologia. Por isso, é necessário avaliar os diferentes métodos de diagnóstico existentes e assim fornecer dados para o estabelecimento de conduta padronizada. Objetivo: Avaliar a fibronasofaringolaringoscopia flexível como teste diagnóstico de hiperplasia adenoideana em crianças com obstrução nasal, comparado com teste de referência. E também, determinar se a obstrução do toro tubário por hiperplasia adenoideana altera pressões de orelha média. Delineamento: Estudo transversal. Metodologia: Foram avaliadas cento e trinta crianças consecutivas, com idade entre 02 a 12 anos, no período de maio a outubro de 2005. O tamanho adenoideano foi avaliado por meio da radiografia de rinofaringe pelo método de Cohen e Konak; e pela classificação de Wormald e Prescott durante a fibronasofaringolaringoscopia flexível. Foi considerado como teste de referência à associação do escore clínico com os resultados radiológicos. O escore clínico foi obtido por meio de questionário direcionado aos pais ou responsáveis pela criança. Em cinqüenta crianças foram avaliados o toro tubário por meio da fibronasofaringolaringoscopia flexível e alterações pressóricas na orelha média pela timpanometria. Resultados: A sensibilidade da fibronasofaringolaringoscopia flexível foi de 92% (IC de 95%, 0,85-0,98) e a especificidade de 84% (IC de 95%, 0,75-0,93). A área sob a curva ROC foi de 0,89 (IC de 95%, 0,82-0,95), com nível de significância p<0,001.O valor Kappa interobservador foi de 0,94, intra-observador de 0,95 e entre os testes de0,75. Em 87% das crianças nas quais os toros tubários estavam ocluídos pelo tecido adenoideano, a timpanometria foi sugestiva de pressão alterada na orelha média. Em toros livres, 86% dos achados timpanométricos estavam normais (p<0,001). Conclusões: A fibronasofaringolaringoscopia flexível sugere ser um método diagnóstico com altos níveis de acurácia para avaliação de hiperplasia adenoideana. Demonstrou-se existir associação entre o grau de obstrução sobre os toros tubários, ocasionados pela hiperplasia adenoideana, com alterações na timpanometria sugestivas de alteração pressórica na orelha média. / Adenoid hypertrophy is considered one of the most common cause of nasal obstruction in children, and it is directly associated with local phlogistic manifestations such as rhinosinusitis, otitis and systemic diseases. However the actual role and influence of adenoid size in these chronic diseases remains controversial. Discovering the etiology of nasal obstruction in children is an almost daily practice at an ENT clinic. In view of these facts, it is considered necessary to evaluate the different currently used diagnostic methods and thus supply data to establish a standardized management. Objective: To evaluate flexible nasofiberendoscopy as a diagnostic test of adenoid hypertrophy in children with nasal obstruction, compared with a reference test. And also, to determine whether the obstruction of the Eustachian tube orifice, as a result of adenoid hypertrophy, alters pressures in middle ear. Study design: Cross-sectional. Method: One hundred and thirty consecutive children, aged 2 to 12 years, were assessed from May to October 2005. Adenoid size evaluation was performed by X-ray of the cavum using the Cohen and Konak method and by the classification of Wornald and Prescott during the flexible nasofiberendoscopy It was considered as Reference Test the associations of the symptomatology score with the radiological measurements. The symptomatology score was obtained through a questionnaire addressed to the parents or to the person responsible for the child. In fifty children the status of the Eustachian tube orifice were assessed with flexible nasofiberendoscopy and middle ear evaluation was performed by tympanometry. Results: Flexible nasofiberendoscopy sensitivity was 92% (95% CI, 0.85-0.98) and specificity 84% (95% CI, 0.75-0.93). The area under the ROC curve was 0.89 (95% CI, 0.82-0.95), with a p<0.001 level of significance. The Kappa value for inter-observer agreement was 0.94, intra-observer 0.95 and among the tests 0.75.In children with Eustachian tube orifice occlusion by adenoid tissue, the tympanogram suggested that 87% had abnormal pressure in the middle ear. In ostia that were not occluded, 86% of the tympanogram results were normal (p<0.001). Conclusion: Flexible nasofiberendoscopy appears to be a highly accurate diagnostic method. This study showed a significant association between the obstruction of the Eustachian tube orifice, caused by adenoid hypertrophy, and tympanogram results suggestive of abnormal pressure in the middle ear.
69

Comparação da pressão arterial, aferida por mapa, após sessão de hemodiálise, em pacientes submetidos à avaliação clínica ou bioimpedância, para determinação de peso seco

Lara, Darlan Martins January 2010 (has links)
Introdução: Há uma forte conexão entre doença renal e risco para doença cardiovascular. A hipertensão arterial é o fator mais importante associado com ambas as condições. Em pacientes em hemodiálise, o primeiro passo na obtenção de um melhor controle da pressão arterial é estabelecer o melhor peso seco. Tradicionalmente, o peso seco é definido a partir da avaliação clínica, por tentativa e erro. A bioimpedância pode avaliar a água corporal total e ajudar no ajuste do peso seco. O objetivo foi avaliar a redução do peso seco e da pressão arterial a partir de duas estratégias de determinação do peso ideal em pacientes renais crônicos, em programa hemodialiítico. Métodos: Trata-se de um ensaio clínico, no qual 70 pacientes, com idades entre 23 e 79 anos, foram randomizados para o grupo de avaliação clínica somente (n=36) ou para avaliação clínica mais bioimpedância elétrical tetramodal (n=34). Medidas de pressão arterial, por meio de monitorização ambulatorial da pressão arterial de 24 horas (MAPA-24h), e a ocorrência de sintomas intradialíticos foram obtidas antes e duas semanas após a intervenção. Os grupos foram comparados por intermédio de teste χ 2, Teste t ou Mann-Whitnney. A interação tempo-grupo das medidas pressóricas foram analisadas por meio de teste de variança para medidas repetidas (MANOVA). Resultados: As características dos grupos foram semelhantes. A redução nas pressões arteriais, sistólica e diastólica, não diferiu entre os grupos de intervenção. Observou-se uma maior redução de peso nos pacientes do grupo da bioimpedância. Houve uma diferença significativa (P=0,008) na redução do peso seco no grupo da bioimpedância (mediana=0,5kg, percentil 25-75=0,0 a 1,0Kg) em relação ao grupo da avaliação clínica (mediana=0,0kg, percentil 25-75=0,0 a 0,5Kg). A maior redução de peso no grupo de bioimpedância não implicou em aumento das complicações intradialíticas. Encontrou-se, também, que a proporção de pacientes que não tiveram seu peso reduzido foi significativamente diferente (P=0,009), sendo 69,4% (25 de 36) no grupo da avaliação clínica contra 38,2% (13 de 34) no grupo de bioimpedância. Conclusão: A biompedância elétrica tetramodal não resultou em uma variação significativa na pressão sistólica e diástolica, aferida por MAPA-24h, num acompanhamento de duas semanas. Seu benefício na redução da pressão arterial deve ser melhor avaliado em estudo com um período de seguimento mais longo. Em relação à avaliação do peso seco, a BIE mostrou-se um método útil, por permitir uma maior redução de peso, sem aumentar as intercorrências intradialíticas. Sua aplicação, complementar à avaliação clínica, pode somar as qualidades dos dois métodos, contribuindo para o manejo clinico, bem-estar e qualidade de vida do doente renal crônico em tratamento dialítico.
70

bioimpedância elétrica : análise de interferência em dispositivos cardíacos eletrônicos implantáveis

Garlini, Luiza Matos January 2017 (has links)
Resumo não disponível.

Page generated in 0.0223 seconds