• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 11
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 112
  • 112
  • 94
  • 82
  • 79
  • 77
  • 74
  • 73
  • 73
  • 46
  • 44
  • 34
  • 28
  • 27
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Análise da deformação gerada nos intermediários e na região óssea peri-implantar sob diferentes condições de carga em prótese parcial fixa parafusada / Strain analysis of abutment and bone tissue around dental implants under different loading conditions on screw-retained fixed partial prostheses

Costa, Max Doria 04 August 2015 (has links)
O sucesso a longo prazo dos implantes tem como fatores críticos a incidência e a transferência de estresses mecânicos sobre a prótese, intermediários, implantes e destes para o tecido ósseo adjacente, devendo cada parte deste sistema ser submetido somente a forças às quais estão aptos a receber. A proposta deste trabalho foi avaliar a deformação gerada nos intermediários e na região óssea peri-implantar diante da aplicação de cargas funcionais e parafuncionais em prótese parcial fixa de três elementos parafusadas sobre dois implantes. Para este trabalho, foi utilizado um modelo experimental homogêneo à base de poliuretano, simulando o tecido ósseo, com dois implantes do tipo hexágono externo paralelos que receberam intermediários do tipo multi-unit. Na superfície de cada intermediário foram instalados três sensores (strain gauges), capazes de medir a microdeformação dispostos de maneira eqüidistante entre si. Na região óssea simulada, foram instalados quatro sensores para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. A aplicação da carga estática de 300N foi realizada em uma máquina de ensaios universais. As leituras foram realizadas em quatorze momentos para todos os corpos de prova, variando o direcionamento da carga (axial e inclinada à 30 graus) e simulando ainda sete diferentes pontos de aplicação de carga (1- pilar mesial, 2 - pôntico, 3- pilar distal, 4- simultaneamente no pilar mesial, pontico e pilar distal, 5- no pilar mesial e distal, sem contato no pôntico, 6- no pilar mesial e no pôntico, 7- no pilar distal e no pôntico). Os resultados mostraram que a direção da carga interferiu na magnitude e distribuição da microdeformação, de forma que, no osso simulado, os valores encontrados na carga axial se encontraram dentro da tolerância fisiológica independente do local de aplicação de carga. Observou-se uma distribuição mais uniforme quando a carga foi aplicada simultaneamente nos pilres mesial, pôntico e pilar distal. Por outro lado, valores de microdeformação acima do limite de tolerância foram observados para a carga inclinada e nesta situação o local de aplicação teve influência na microdeformação, com valores extremamente elevados e sem uniformidade na distribuição, devendo o carregamento oblíquo ser evitado. / Long-term success with implants has some critical factors such as incidence and transmission of mechanical stress to the prosthesis, abutments, and implants to the adjacent bone tissue. Each part of the system should be subjected to loads under its strength limit. The purpose of the present study was to evaluate abutment and peri-implant bone tissue strains during functional and parafunctional loads application in a three-unit screw-retained fixed prosthesis supported by two implants. In order to simulate the bone tissue, an experimental model made of homogeneous polyurethane was used wherein two external hexagon implants were placed parallel to each other, provided with multi-unit abutments. On the surface of each abutment three sensors (strain gauges) were positioned equidistant to each other to measure microstrains. The simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The tests were performed applying a 300N static load on a universal testing machine. The readings were made at fourteen moments for each specimen, changing load direction (axial and 30 degrees oblique) and also simulating seven different points of load application (1- mesial abutment, 2- pontic, 3- distal abutment, 4- simultaneously on the mesial abutment, pontic and distal abutment, 5- mesial and distal abutment (no pontic contact), 6- mesial abumtent and pontic, 7- distal abutment and pontic. The results showed that the load direction significantly influenced the magnitude and distribution of microstrains, so that for the simulated bone, the values found during axial load were within the physiological threshold independent of the point of load application; however, a more uniform distribution was observed when force was applied simultaneously on the mesial abutment, pontic and distal abutment. Furthermore, microstrain values above the tolerance limits were observed during oblique load, and for this condition, the point of load application significantly influenced the microstrains, with extremely high values and non-uniform distribution for all load conditions tested. Therefore, oblique loading must be avoided.
52

Avaliação clínica e radiográfica de implantes curtos: estudo retrospectivo no período de 7 anos / Clinical and radiographic evaluation of short implants: retrospective study for a period of 7 years

Ayub, Karen Vaz 23 February 2018 (has links)
Áreas edêntulas com severa reabsorção óssea têm sido reabilitadas com próteses fixas instaladas sobre implantes curtos, evitando que os pacientes sejam submetidos a cirurgias de reconstrução óssea. Este estudo retrospectivo descreve o comportamento de implantes curtos avaliados em um período de 7 anos. A amostra foi composta por 70 pacientes, de ambos os gêneros, que receberam 136 implantes, de 6 ou 8mm de comprimento (Straumann® bone level e tissue level standard plus) sobre os quais foram instaladas próteses unitárias e múltiplas, cimentadas e parafusadas. Foram realizadas avaliações clínicas e radiográficas mensurando a estabilidade do implante por frequência de ressonância, perda óssea marginal por meio de radiografias panorâmicas, índices de placa e de sangramento marginal, taxas de sobrevivência do implante e da prótese. Dois implantes instalados na mandíbula foram perdidos, resultando em uma taxa de sobrevivência de 98,3%. A taxa de sobrevivência das próteses foi de 100%; a média de perda óssea foi de - 0,28mm; a estabilidade média dos implantes foi de 76,515 ISQ; as médias dos índices de placa e de sangramento foram de 32,83% e 33,21%, respectivamente. A estabilidade do implante foi maior na mandíbula que na maxila (p = 0,006). Os resultados obtidos nesta pesquisa, possibilitam afirmar que os implantes curtos podem ser utilizados com segurança dentro de suas indicações específicas. / Edentulous areas with severe bone resorption have been rehabilitated with fixed prostheses installed on short implants, avoiding surgeries of bone reconstruction. This retrospective study describes the behavior of short implants evaluated during 7 years. The sample consisted of 70 patients, of both genders, who received 136 implants, 6 or 8mm in length (Straumann® bone level and tissue level standard plus) on which single and multiple, cemented and screwed prostheses were installed. Clinical and radiographic evaluations were performed by measuring implant stability by resonance frequency, marginal bone loss by panoramic radiographs, plaque and marginal bleeding rates, the implant and prostheses survival rates. Two implants installed in mandible were lost, resulting in a survival rate of 98,3%. The prostheses survival rate was 100%; mean bone loss was -0,28mm; mean implants stability was 76,52 ISQ; mean plaque and bleeding indexes were 32,83% and 33,21%, respectively. The implant stability was higher in the mandible than in the maxilla (p = 0.006). The results obtained in this research make it possible to state that short implants can be used safely within their specific indications.
53

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Tiossi, Rodrigo 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92μm), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10μm e Ti cp: 48,41 ± 26,69μm). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76μm, Ni-Cr: 20,13 ± 7,97μm, e Ti cp: 22,28 ± 17,29μm, e no lado contrário: Co-Cr: 118,64 ± 91,48μm, Ni-Cr: 70,66 ± 20,88μm, e Ti cp: 118,56 ± 51,35μm. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08μm). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81μm) e Ti cp (17,70 ± 11,70μm), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36μm) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15μm) e em Ti cp (40,42 ± 27,14μm) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67μm, após a simulação, quando era 41,02 ± 26,15μm após soldagem a laser para o primeiro e, 40,42 ± 27,14μm e 28,05 ± 20,89μm, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92μm), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10μm e Cp Ti: 48.41 ± 26.69μm). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76μm, Ni-Cr: 20.13 ± 7.97μm, and Cp Ti: 22.28 ± 17.29μm, and on the opposite side: Co-Cr: 118.64 ± 91.48μm, Ni-Cr: 70.66 ± 20.88μm, and Cp Ti: 118.56 ± 51.35μm. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08μm). For the other two groups, Ni-Cr alloy (13.10 ± 1.81μm) and Cp Ti (17.70 ± 11.70μm), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36μm) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15μm) and the Cp Ti (40.42 ± 27.14μm) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67μm, after simulation, when was 41.02 ± 26.15μm after laser welding for the first and, 40.42 ± 27.14μm and 28.05 ± 20.89μm, before and after, for the second, though not showing any statistically significant differences.
54

Influência da inclinação das cúspides, tipo de retenção e envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas sobre implantes / Influence of cusp inclination, type of retention and mechanical aging on fracture strenght of the implant-supported metal-ceramics crowns

Rocha, Cibele Oliveira de Melo [UNESP] 31 July 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-31. Added 1 bitstream(s) on 2017-03-14T14:42:44Z : No. of bitstreams: 1 000874660.pdf: 1969189 bytes, checksum: 5bdc581e4bd9de3fcf1b285eb40d888b (MD5) / O objetivo do estudo foi avaliar a influência da inclinação das cúspides, do tipo de retenção e do envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas implanto-suportadas. Para o ensaio estático utilizou-se seis grupos (n=10): coroas cimentadas com cúspide de inclinação padrão (CIP) de 33º ou cúspides de inclinação reduzida (CIR) de 20°, parafusadas com o orifício de acesso ao parafuso (OAP) não-restaurado com CIP ou CIR e parafusadas com OAP restaurado com CIP ou CIR. Para o efeito do envelhecimento, 4 grupos foram utilizados (n=20): cimentadas com CIP ou CIR; e parafusadas com OAP não-restaurado com CIP ou CIR, em que 50 % das amostras de cada grupo foram cicladas mecanicamente previamente ao ensaio estático. Coroas de um segundo molar inferior foram confeccionadas sobre análogos de implante hexágono externo 5.0 (Biomet 3i, West Palm Beach, FL). O ensaio estático foi realizado aplicando-se força até a fratura da porcelana e para o efeito do envelhecimento, a ciclagem foi realizada (1 x 106; 125 N; 10Hz) antes do ensaio de resistência máxima à fratura. Após análise estatística observou-se que as médias de resistência à fratura apresentaram efeito significativo para Forma de Retenção (FR) e Inclinação de cúspide (IC) (p<0,01). Para FR apenas as coroas parafusadas não apresentaram diferenças estatísticas entre si (p>0,05), porém ambas apresentaram valores estatisticamente menores do que as cimentadas. Para IC, CIP apresentaram menores valores de resistência à fratura. Após o envelhecimento mecânico foi observado efeito significativo somente para os fatores isolados Forma de Retenção e Inclinação de cúspide (p<0,01), com melhores resultados para coroas cimentadas e CIR, respectivamente. O fator Envelhecimento Mecânico (p=0,659) não apresentou efeito significativo. Diante dos resultados, conclui-se que isoladamente... (Resumo completo, clicar acesso eletrônica abaixo) / The aim of this study was evaluate the influence of cusp inclination, type of retention and mechanical aging on fracture strength of implant-supported metal-ceramic (MC) single crowns. To static test, six groups were used (n=10): cemented crowns with 33° standard cusp inclination (SCI) or with 20° reduced cusp inclination (RCI), screwed crowns with screw access hole (SAH) not restored with SCI or RCI and screwed crowns with SAH restored with SCI or RCI. To test aging effect, 4 groups were used (n=20): cemented with SCI or RCI; and screw-retained with SAH not restored with SCI or RCI, in which 50% of specimens of each group were submitted to mechanical aging previously to static test. Crowns of a lower second molar were made on the analog implant external hexagon 5.0 (Biomet 3i, West Palm Beach, FL). The cycling (1.106; 125N; 10Hz) will be performed before the fracture resistance test. The static test was performed in a universal testing machine EMIC DL2000, with load application until porcelain failure. After statistical analysis it was observed that the mean fracture resistance of porcelain showed significant effect (p<0.01), to type of retention (TR) and cusp inclination (CI), respectively. To TR, screwed crowns did not show statistical differences (p>0.05), however, both two showed statistically lower values than cemented. To CI, crowns with SCI showed lower values of fracture resistance. After mechanical aging, TR and CI showed significant effect (p<0.01), with better results to cemented crowns and RCI, respectively. The factor mechanical aging did not show significant effect (p=0.659). According to these results, it was concluded that alone, type of retention and the cusp inclination showed influence on fracture resistance of MC crowns, being cemented crowns and reduced cusps mechanically more resistant against a static and cyclic load. The mechanical aging had no significant... (Complete abstract electronic access below)
55

Análise da desadaptação marginal vertical e horizontal de infraestruturas de próteses fixas implantossuportadas confeccionadas através de diferentes técnicas /

Gomes, Jéssica Marcela de Luna. January 2018 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientadora: Sandra Lúcia Dantas de Moraes / Banca: Fellippo Ramos Verri / Banca: Mônica Maria Albuquerque Pontes / Resumo: O objetivo deste trabalho foi avaliar a desadaptação marginal vertical, horizontal e interna de infraestruturas e próteses fixas implantossuportadas confeccionadas através de diferentes técnicas. Além disso, realizar uma revisão sistemática e meta-análise avaliando o efeito da soldagem de infraestruturas de próteses fixas implantossuportadas em uma melhor adaptação quando comparada as infraestruturas confeccionadas em monobloco. Um total de 30 infraestruturas foram confeccionadas e divididas em 3 grupos: G1) Técnica convencional da cera perdida (n=10); G2) CAD/CAM (n=10); G3: CAD/CAM + Técnica da cera perdida (n=10). Uma matriz foi utilizada para simular uma prótese fixa implantossuportada de três elementos com um pôntico central. A infraestrutura do grupo G1 foi confeccionada em Ni-Cr, do grupo G2 em zircônia e G3 fresada em cera e fundida em Ni-Cr. Em todos os grupos a desadaptação marginal vertical e horizontal (subcontorno e sobrecontorno) foi avaliada através de um microscópio óptico tridimensional (Quick Scope, Mitutoyo). A revisão sistemática seguiu o critério PRISMA e está cadastrada na plataforma PROSPERO (CRD81865) e a busca foi realizada nas bases de dados Pubmed/MEDLINE, Embase and The Cochrane Library com artigos publicados até novembro de 2017. A questão PICO foi: "A técnica do ponto de solda contribui para uma melhor adaptação quando comparada a confecção em monobloco de infraestruturas e próteses fixas implantossuportadas?". O estudo in vitro demonstrou maior ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the marginal vertical, horizontal and internal misfit of implant-supported prostheses made through different techniques. In addition, to perform a systematic review and meta-analysis evaluating the effect of the welding technique on fixed prosthesis implants supported in make a better adaptation when compared the infrastructures made in one piece cast. A total of 30 infrastructures were made and divided into 3 groups: G1) Conventional- lost wax technique (n = 10); G2) CAD/CAM (n = 10); G3: CAD/CAM + lost wax technique (n = 10). A reference model was used to to simulate a 3-unit implant-supported fixed prostheses with a central pontic. In the G1 group the frameworks were made of Ni-Cr alloy, G2 group in zirconia and G3 milled in wax and fused in Ni-Cr alloy. In all groups, vertical and horizontal marginal misfit (under-contour and over-contour) was evaluated using a 3D optical microscope (Quick Scope, Mitutoyo, Japan). The systematic review and meta-analysis followed the PRISMA criteria and is registered on the PROSPERO (CRD81865). The search was performed in the Pubmed/MEDLINE, Embase and The Cochrane Library databases with selection of articles published until November 2017. The PICO question was: "The welding technique contributes to a better adaptation when compared to the one-piece cast frameworks of implant-supported prostheses?" The in vitro study showed a higher value of vertical marginal misfit for the G3 group (83.5μm), followed ... (Complete abstract click electronic access below) / Mestre
56

Avaliação do exame radiográfico convencional e digital e digital no diagnóstico da adaptação entre implantes dentários e protéticos

Duarte, Glauber Vieira January 2007 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:44:03Z No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:01:18Z (GMT) No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Made available in DSpace on 2013-05-16T18:01:18Z (GMT). No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) Previous issue date: 2007 / A Implantologia é uma das modalidades de reabilitação bucal, inclusive pela alta taxa de sucesso das próteses implanto-suportadas. No entanto, estão sujeitas a alguns problemas exclusivos, como o afrouxamento do parafuso e a fratura do parafuso de fixação. A adaptação marginal de um pilar protético sobre o implante é imprescindível para que muitas destas falhas não ocorram. Além disso, desadaptações e cavidades entre estes componentes podem favorecer o acúmulo de bactérias e causar reações inflamatórias nos tecidos periimplantares. O estudo da adaptação marginal entre estes componentes faz parte de uma linha de pesquisa, com o objetivo de estabelecer um método diagnóstico padronizado, eficaz e reprodutível de avaliação. O presente estudo propôs-se a verificar a validade do método radiográfico convencional e sistema digital Digora, quanto à capacidade diagnóstica da adaptação marginal de cinco pilares protéticos, em titânio Procera Alltitan®, com diferentes aberturas entre o implante e o pilar protético. Os pilares foram aparafusados em um implante, que foi posteriormente fixado a uma base metálica hexagonal, permitindo a padronização das tomadas radiográficas e da avaliação microscópica. Os pilares foram avaliados quanto a sua adaptação no implante, utilizando um microscópio óptico comparador (Mitutoyo®), utilizado como padrão-ouro do estudo. Foram utilizados matrizes de poliéster em tiras com o intuito de obter aberturas marginais padronizadas de 50µm, 100µm, 150µm e 200µm, considerando que cada tira possui uma espessura de 50µm. Em cada sistema foram realizadas 75 tomadas radiográficas (15 de cada grupo de abertura marginal), obtendo imagens com cinco tipos de adaptação (adaptado, 50µm, 100µm, 150µm e 200µm). Deste modo, foram avaliados 150 pontos proximais, em cada sistema radiográfico. Dois radiologistas avaliaram as imagens e para a análise estatística foi utilizada uma matriz de decisões para a realização dos testes diagnósticos de: sensibilidade, especificidade, acurácia, valor preditivo positivo e negativo e a medida estatística Kappa. Os resultados obtidos indicaram que os sistemas radiográficos, convencional e digital, possuem alta sensibilidade, especificidade, acurácia, valores preditivos e bom nível de concordância com o grupo-ouro, com uma discreta, mas não relevante, redução da eficácia diagnóstica do sistema digital. Observou-se que os sistemas radiográficos avaliados são excelentes ferramentas de diagnóstico quando aberturas marginais maiores que 50µm não são aceitáveis. Deve-se considerar que o sistema radiográfico digital Digora® possui grandes vantagens sobre o sistema convencional, como a redução da dose de radiação, a eliminação de erros humanos durante o processamento e a economia de tempo. Deste modo, o sistema Digora pode ser incluído como uma ferramenta de grande importância na reabilitação protética sobre implantes. / Salvador
57

Desadaptação marginal na interface de pilares cerâmicos procera parafusados a diferentes sistemas de implantes

Cunha, Tiago de Morais Alves da January 2008 (has links)
93f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-24T14:16:56Z No. of bitstreams: 1 Dissertacao - Tiago Cunha.pdf: 763526 bytes, checksum: db4a0e2212c5cc1a1da94e961899507d (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:50:18Z (GMT) No. of bitstreams: 1 Dissertacao - Tiago Cunha.pdf: 763526 bytes, checksum: db4a0e2212c5cc1a1da94e961899507d (MD5) / Made available in DSpace on 2013-05-08T11:50:18Z (GMT). No. of bitstreams: 1 Dissertacao - Tiago Cunha.pdf: 763526 bytes, checksum: db4a0e2212c5cc1a1da94e961899507d (MD5) Previous issue date: 2008 / Embora sejam fabricados pela Nobel Biocare, as vantagens mecânicas e estéticas dos pilares cerâmicos personalizados Procera têm levado à sua utilização em associação com outros sistemas de implantes compatíveis com o sistema Bränemark. Estudos chamam a atenção para o fato de que a associação de componentes de empresas diferentes das dos fabricantes dos implantes gera diferenças estatisticamente significativas na adaptação marginal, quando comparados a implantes parafusados a componentes de um mesmo fabricante. Objetivo. Através deste estudo, buscou-se avaliar, através de microscopia eletrônica de varredura (MEV), a desadaptação marginal na interface entre implante e pilar de pilares cerâmicos personalizados Procera, parafusados a diferentes sistemas de implantes compatíveis com o sistema Branemärk. Métodos. Aplicação de questionário a profissionais especialistas em prótese dentária com perguntas relativas ao planejamento das próteses sobre implantes e aos sistemas sobre os quais esses pilares costumam ser utilizados, a fim de se delinearem os grupos experimentais a serem estudados. Com base nas informações coletadas, foram selecionados doze pilares personalizados Procera em Zircônia e doze implantes de hexágono externo e plataforma regular, compatíveis com o sistema Bränemark, divididos em três grupos com quatro amostras cada: (1) SIN (ES), (2) Conexão (EC) e (3) Nobel Biocare (GCN). Resultados. As médias e desvios padrões determinados para cada grupo foram submetidos à ANOVA e, em seguida, ao Teste Tukey, para se determinar a significância das diferenças entre os grupos estudados. As médias de desadaptação marginal na interface entre implante e pilar para cada grupo foram: 9,53µm ±0,52, 10,62µm ±2,16 e 5,7µm ±0,39, respectivamente para os grupos ES, EC e GCN. Conclusão. Os resultados obtidos evidenciaram uma diferença significativa entre os grupos (p=0,001), com valor de desadaptação marginal menor para o grupo de controle (GCN), enquanto que, para os grupos ES e EC, embora tivessem sido constatados valores similares, eles diferiram estatisticamente dos do grupo de controle, indicando, portanto, maior desajuste. / Salvador
58

Cantilever em Próteses : análise da deformação de estruturas metálicas em NiCr, com diferentes configurações, em função da carga aplicada /

Alves, Luciana Mara Negrão. January 2010 (has links)
Orientador: Humberto Gennari Filho / Banca: Maria Cristina Rosifini Alves Rezende. / Banca: Ricardo Shibayama / Resumo: O êxito clínico nos tratamentos com próteses fixas implanto-suportadas com cantilever é determinado pela maneira como o estresse mecânico é transferido ao implante e ao tecido ósseo circundante sem gerar forças de grande magnitude e pelo estado de saúde dos tecidos adjacentes. Nestes tratamentos, as tensões oclusais se concentram nas extensões distais havendo uma maior incidência de fratura da estrutura, na união entre a prótese e o implante mais distal. Reconhecendo a influência do desenho da estrutura do cantilever sobre os implantes, bem como a necessidade dessas terem formatos que facilitem a higienização e manutenção do tecido periimplantar, o objetivo desse estudo será analisar a relação entre a força aplicada e a deformação ocorrida em barras para cantilever, com áreas de secção transversal em forma de triangulo, quadrada, semi lua, em L e I, através de uma Máquina de Ensaio Universal "EMIC". Serão confeccionadas 25 barras, em liga de NiCr, divididas em 5 grupos, um para cada formato de barra, com 5 corpos de prova cada um. Uma carga vertical de 200N será aplicada na extremidade do segmento de 15 mm, com velocidade de 0,5mm por minuto. As barras que suportaram uma maior carga foram as em formato quadrado, seguida pela meia lua, L, triangular sendo a em formato de I a que suporta menor força de mordida. Houve diferenças estatisticamente significantes quando comparadas as em formato quadrado em relação às outras formas e as em meia lua também com as outras formas, sendo que as em formato de L, I e triangular não apresentaram diferenças estatisticamente significantes. É importante definirmos corretamente o formato da secção transversal da barra do cantilever de uma prótese, em função de sua relação com a classe de prótese antagônica, para que não haja deformação durante a função proporcionando estruturas leves, confortáveis e com espaço suficiente para higienização / Abstract: The clinical success in treatment with implant-supported fixed prostheses with cantilever is determined by how the mechanical stress is transferred to the implant and the surrounding bone without generating forces of great magnitude and the health of tissues. In these treatments, the occlusal stress focus on the distal extensions and a higher incidence of fracture of the structure, the bond between the prosthesis and the most distal implant. Recognizing the influence of the cantilever design of the structure on implants, and the need to have these formats to facilitate the cleaning and maintenance of peri-implant tissue, the aim of this study will examine the relationship between the applied force and deformation occurred in bars for cantilever with areas of cross section in the shape of triangle, square, half moon, L and I, through a Universal Testing Machine "EMIC". 25 bars will be made in NiCr, divided into five groups, one for each bar shape, with five specimens each. 200N of a vertical load is applied at the end of the segment of 15mm with a speed of 0.5 mm per minute. The bars that bore a greater burden were square in shape, then the half moon, L, and the triangular-shaped supports that I less bite force. There were statistically significant differences when comparing the square in shape relative to other forms and in a half-moon also with other forms, and the L-shaped, triangle and I did not show statistically significant differences. It is important to properly define the shape of the cross section bar of the cantilever of a prosthesis, because of its relationship with the class of prosthesis antagonistic, so that no deformation during function, providing lightweight structures, comfortable with enough space for cleaning / Mestre
59

Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /

Santiago Júnior, Joel Ferreira. January 2010 (has links)
Resumo: A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Paulo Sérgio Perri de Carvalho / Banca: Alcides Gonini Júnior / Mestre
60

Influência da inclinação das cúspides, tipo de retenção e envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas sobre implantes /

Rocha, Cibele Oliveira de Melo. January 2015 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Francisco de Assis Mollo Junior / Banca: Ricardo Faria Ribeiro / Resumo: O objetivo do estudo foi avaliar a influência da inclinação das cúspides, do tipo de retenção e do envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas implanto-suportadas. Para o ensaio estático utilizou-se seis grupos (n=10): coroas cimentadas com cúspide de inclinação padrão (CIP) de 33º ou cúspides de inclinação reduzida (CIR) de 20°, parafusadas com o orifício de acesso ao parafuso (OAP) não-restaurado com CIP ou CIR e parafusadas com OAP restaurado com CIP ou CIR. Para o efeito do envelhecimento, 4 grupos foram utilizados (n=20): cimentadas com CIP ou CIR; e parafusadas com OAP não-restaurado com CIP ou CIR, em que 50 % das amostras de cada grupo foram cicladas mecanicamente previamente ao ensaio estático. Coroas de um segundo molar inferior foram confeccionadas sobre análogos de implante hexágono externo 5.0 (Biomet 3i, West Palm Beach, FL). O ensaio estático foi realizado aplicando-se força até a fratura da porcelana e para o efeito do envelhecimento, a ciclagem foi realizada (1 x 106; 125 N; 10Hz) antes do ensaio de resistência máxima à fratura. Após análise estatística observou-se que as médias de resistência à fratura apresentaram efeito significativo para Forma de Retenção (FR) e Inclinação de cúspide (IC) (p<0,01). Para FR apenas as coroas parafusadas não apresentaram diferenças estatísticas entre si (p>0,05), porém ambas apresentaram valores estatisticamente menores do que as cimentadas. Para IC, CIP apresentaram menores valores de resistência à fratura. Após o envelhecimento mecânico foi observado efeito significativo somente para os fatores isolados Forma de Retenção e Inclinação de cúspide (p<0,01), com melhores resultados para coroas cimentadas e CIR, respectivamente. O fator Envelhecimento Mecânico (p=0,659) não apresentou efeito significativo. Diante dos resultados, conclui-se que isoladamente... (Resumo completo, clicar acesso eletrônica abaixo) / Abstract: The aim of this study was evaluate the influence of cusp inclination, type of retention and mechanical aging on fracture strength of implant-supported metal-ceramic (MC) single crowns. To static test, six groups were used (n=10): cemented crowns with 33° standard cusp inclination (SCI) or with 20° reduced cusp inclination (RCI), screwed crowns with screw access hole (SAH) not restored with SCI or RCI and screwed crowns with SAH restored with SCI or RCI. To test aging effect, 4 groups were used (n=20): cemented with SCI or RCI; and screw-retained with SAH not restored with SCI or RCI, in which 50% of specimens of each group were submitted to mechanical aging previously to static test. Crowns of a lower second molar were made on the analog implant external hexagon 5.0 (Biomet 3i, West Palm Beach, FL). The cycling (1.106; 125N; 10Hz) will be performed before the fracture resistance test. The static test was performed in a universal testing machine EMIC DL2000, with load application until porcelain failure. After statistical analysis it was observed that the mean fracture resistance of porcelain showed significant effect (p<0.01), to type of retention (TR) and cusp inclination (CI), respectively. To TR, screwed crowns did not show statistical differences (p>0.05), however, both two showed statistically lower values than cemented. To CI, crowns with SCI showed lower values of fracture resistance. After mechanical aging, TR and CI showed significant effect (p<0.01), with better results to cemented crowns and RCI, respectively. The factor mechanical aging did not show significant effect (p=0.659). According to these results, it was concluded that alone, type of retention and the cusp inclination showed influence on fracture resistance of MC crowns, being cemented crowns and reduced cusps mechanically more resistant against a static and cyclic load. The mechanical aging had no significant... (Complete abstract electronic access below) / Mestre

Page generated in 0.0419 seconds