Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães /

Lenharo, Ariel. January 2003 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Marco Antonio Bottino / Banca: Luiz Fernando Pegoraro / Banca: Mauro Antônio Arruda Nóbilo / Banca: Tetuo Okamoto / Resumo: O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / Abstract: The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation. / Doutor
22

Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado : análises biomecânica, microscópica e histométrica em cães /

Mendes, Vanessa Cristina. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / Abstract: The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn't be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups. / Doutor
23

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Renato Martins 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
24

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Marcus Vinicius Cobein 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
25

Avaliação da resistência à fratura de próteses unitárias sobre implantes revestidas em resina composta laboratorial com reforço de fibras de vidro

FREITAS, Alysson Cruz de January 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T14:28:37Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-29T15:43:22Z (GMT) No. of bitstreams: 2 Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-29T15:43:22Z (GMT). No. of bitstreams: 2 Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / O sucesso dos implantes osseointegrados é comprovado cientificamente e com isso, veio outras preocupações como a de se solucionar esteticamente e funcionalmente o tratamento restaurador, tendo como escolha na maioria das vezes a confecção de coroas metalocerâmicas ou metaloplásticas. Este trabalho teve como objetivo comparar a resistência à fratura por compressão axial e avaliar o tipo de fratura de 30 coroas unitárias sobre implante do primeiro pré-molar superior, confeccionadas com diferentes infraestruturas metálicas (infra-estruturas enceradas e fundidas em níquel-cromo sobre pilares UCLA calcináveis e infra-estruturas representadas por pilares UCLA provisórios pré-fabricados em titânio), ambos restaurados com resina composta laboratorial, sendo que, as restaurações totais em resina compostas laboratoriais confeccionadas sobre o pilar UCLA pré-fabricado em titânio foram reforçadas internamente com fibras de vidro. Não foram encontradas diferenças estatisticamente significantes entre as médias tanto de resistência à fratura quanto da deformação máxima de rompimento entre os grupos (p= 0.5812 e p= 0.1743 respectivamente). As fraturas apresentadas pelos espécimes com infra-estruturas fundidas em níquel-cromo com e sem retenção apresentaram em sua totalidade fraturas parciais adesivas enquanto que no grupo com infra-estruturas com fibras-de-vidro o tipo de fratura foi a parcial coesiva. A resina composta laboratorial suporta forças acima das encontradas na mastigação indiferente do tipo de reforço utilizado, podendo ser indicada para confecção de próteses unitárias sobre implante. / The success of the osseointegrated implants is proved scientifically and with these, other preoccupations came such as to solve the aesthetically and functionally restoring treatment, having like chosen most times the production of metaloceramic or metaloplastic crowns. This work has the objective to compare the fracture resistance for axial compression of 30 single crowns on implant of the first superior pre-molar, made with different metal infrastructures (infrastructures waxed and fused in nickel-chrome on calcinable UCLA pillars and infrastructures represented by titanium prefabricated provisional UCLA pillars), both restored with laboratory compound resin, being that, the total restorations in laboratory compound resin made on the titanium prefabricated provisional UCLA pillars were reinforced internally with fiberglass. They were not found differences statistically significant between the averages so much of fracture resistance as the deformation (p= 0.5812 and p= 0.1743 respectively). The fractures presented by the specimens with infrastructures fused in nickel-chrome with and without retention presented partial adhesive fractures in its entirety whereas in the group with infrastructures with fiberglass the type of fracture was the partial cohesive one. The compound resin laboratorial supports strength above the considered ones in the mastication, indifferent of the type of the used reinforcement, being able to be indicated for production of implants single prosthesis.
26

Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas /

Del'Acqua, Marcelo Antonialli. January 2005 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Marcelo Ferrarezi de Andrade / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below) / Mestre
27

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado : análise pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2006 (has links)
Resumo: A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / Abstract: The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models. / Orientador: Eduardo Pizza Pellizzer / Coorientador: João Antônio Pereira / Banca: Marcelo Coelho Goiato / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Humberto Gennari Filho / Banca: Dalva Cruz Laganá / Doutor
28

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados /

Munhoz Cháves, Alejandro. January 2009 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Sergio Sualdini Nogueira / Banca: Rafael Leonardo Xediel Consani / Banca: Pedro César Garcia de Oliveira / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que: ...(Resumo completo, cliar acesso eletrônico abaixo) / Abstract: An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material. / Doutor
29

Avaliação da osseointegração promovida por implantes jateados por Al2O3 : análises histológica e histométrica em cães /

Ponzoni, Daniela. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / Abstract: An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias. / Doutor
30

Estudo do comportamento eletromiográfico do masseter e temporal após o tratamento da mordida cruzada posterior funcional com o aparelho quadrihélice /

Santos, José Ricardo Prando dos. January 2004 (has links)
Orientador: Marcos Rogério de Mendonça / Banca: Osmar Aparecido Cuoghi / Banca: Paulo Cesar Tukasan / Resumo: O objetivo deste estudo foi avaliar a atividade eletromiográfica dos músculos masseter e temporal anterior em crianças com mordida cruzada posterior unilateral funcional. A amostra foi composta por 8 crianças com idade de 5 a 10 anos, um menino e sete meninas que não apresentavam hábitos parafuncionais, sintomas neuromusculares como dor ou fadiga e disfunção temporomandibular. As análises eletromiográficas foram realizadas nestes músculos na posição de repouso, máximo apertamento dentário na posição de máxima intercuspidação e durante a mastigação no lado da mordida cruzada e no lado não cruzado, antes (T1) e após (T2) o tratamento da mordida cruzada posterior unilateral funcional com a utilização do aparelho ortodôntico quadrihélice. Os resultados mostraram uma diferença significante somente para o músculo temporal anterior do lado da mordida cruzada para a posição de repouso, mas houve uma tendência para um aumento no temporal anterior do lado não cruzado e para o masseter do lado cruzado, enquanto houve uma diminuição no masseter do lado não cruzado. Durante o apertamento dentário na posição de máxima intercuspidação, todos os músculos monstraram uma tendência ao aumento da atividade eletromiográfica. Durante a mastigação, houve uma tendência para diminuir a atividade em todos os músculos, exceto para o temporal anterior do lado da mordida cruzada, que registrou um aumento. / Abstract: The purpose of this study was to evaluate the electromyographic activity of masseter and anterior temporal muscles in children with unilateral functional posterior crossbite. The sample was compounded of 8 children aged 5 to 10 years, one boy and seven girls that not present parafunctional habits, neuromuscular symptoms referring to pain or fadigue and temporomandibular disfunction. Electromyographic evaluations were carried out in these muscles at rest position, maximal bite in the intercuspal position and during chewing on the crossbite side and on the noncrossbite side, before (T1) and after (T2) unilateral functional posterior crossbite treatment by using quadhelix orthodontic appliance. The results showed significant difference only for anterior temporal muscle on the crossbite side at rest position, but there was tendency to increase in the anterior temporal on the noncrossbite side and in the masseter on the crossbite side, while there was a decrease in masseter on the noncrossbite side. During maximal bite in the intercuspal position before treatment, all muscles showed a tendency to increase the electromyograpihc activity. During chewing, there was a tendency for decrease activity in all muscles, except for anterior temporal on the crossbite side, that registered an increase. / Mestre