Spelling suggestions: "subject:"implantes"" "subject:"aimplantes""
761 |
Osteoblastic cell adhesion on implant surfaces contaminated by Aggregatibacter actinomycetencomitans and treated by photodynamic therapy and chemical decontamination / Adesão de células osteoblásticas em superfícies de implantes contaminadas por Aggregatibacter actinomycetencomitans e tratadas com terapia fotodinâmica e descontaminação químicaBalderrama, Ísis de Fátima 06 April 2018 (has links)
The decontamination process of titanium implants surface is important for the successful treatment of peri-implantitis. The methods of decontamination can be classified in two major groups: chemical or physical. However, the best method of decontamination of implant surfaces is yet undertermined. The aim of this study is to analyze the effectiveness of decontamination of titanium implants surface by chemical conditioning agents and photodynamic therapy, by Scanning Electron Microscopy (SEM) and to analyze the adhesion and proliferation of osteoblastic cells on the previously decontaminated surfaces. Commercially available implants of different brands: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) and Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) were acquired in the market and analyzed in SEM images in 3 different areas (n= 1/group) to determine surface roughness parameters and wettability properties. After that, the surface of dental implants was inoculated with Aggregatibacter actinomycetemcomitans (A.a.) strains for 4 days and prepared for SEM analysis to determine the percentage area of contamination in a software for image analysis. Samples were then decontaminated by two different chemical treatments (citric acid 10% and ethylenediamine tetraacetic acid EDTA - 24%) and photodynamic therapy (methylene blue associated with LASER), both with a 3-minutes application time. In the control group, surfaces were decontaminated with chlorhexidine 0.12% for 3 minutes. The area of decontamination was determined in ImageJ software for SEM images analysis. After decontamination, the adhesion and proliferation of human osteoblastic osteosarcoma cell lineage (Saos-2) on the surface of uncontaminated sterile implants (control; n: 1/period) and decontaminated implants (n: 3/period/group) were investigated. Saos-2 cells [5x104] were seeded on implant surfaces and incubated for 24h (adhesion assay) and 72h (proliferation assay), determined on SEM images. No significant differences were found among the different implants regarding roughness parameters, with exception Rv (SLA: 19.57}4.01 vs. OT: 8.36}7.91; p=0.0031). Chemical composition varied among implants depending on surface treatment, with all groups showing prevalence of Titanium. Values showed greater contact angle (wettability analysis) for NT (hydrophobic) and smaller for ACQ (highly hydrophilic) (p<0.0001). Nanotite/Biomet 3i® showed significantly greater percentage of area contaminated by bacteria (68.19% } 8.63%; p=0.050; Kruskal Wallis/Dunn) than ACQ (57.32% } 5.38%). Osseotite/Biomet 3i® resulted in a smaller remaining contaminated area (50.89% } 9.12%) after decontamination treatments. Increased Saos-2 cells adhesion and proliferation were observed on SLA after 24h (p= 0.0006; ANOVA/Tukey) and 72h (<0.001; ANOVA/Tukey). Decontaminated groups showed significantly less number of cells adhered to the surfaces at 24h and 72h than uncontaminated controls (p < 0.005; ANOVA post hoc Sidak). Regarding decontamination methods, no differences in the number of cells attached to implants treated by photodynamic therapy and chemical agents compared to chlorhexidine at 24h, but implants treated by photodynamic therapy and chemical agents showed greater number of cells attached after 72h. These findings suggest that surface characteristics influenced bacterial contamination and decontamination of implant surfaces; none of the decontamination methods were able to completely remove bacterial contamination, impairing cell adhesion and spreading. These findings may explain the varying clinical results of decontamination methods in re-osseointegration. / O processo de descontaminação de implantes de titânio é importante para o sucesso do tratamento da peri-implantitite. Os métodos de descontaminação podem ser classificados em dois maiores grupos: químico ou físico. Entretanto, o melhor método de descontaminação de superfícies de implantes está ainda indeterminado. O objetivo desse estudo é analisar a efetividade da descontaminação de implantes com superfície de titânio por agentes condicionantes químicos e terapia fotodinâmica, por Microscopia Eletrônica de Varredura (MEV) e analisar a adesão e proliferação de células osteoblásticas previamente com superfícies descontaminadas. Implantes disponíveis comercialmente de diferentes marcas: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) e Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) foram adquiridos no mercado e analisados em imagens de MEV em 3 diferentes áreas (n=1/grupo) para determinar o parâmetro de rugosidade da superfície e a propriedade de molhabilidade. Depois disso, a superfície dos implantes dentários foi inoculada com cepa de Aggregatibacter actinomycetemcomitans (A.a.) por 4 dias e preparada para análise da MEV afim de determinar a área de porcentagem da contaminação em um software de análise de imagem. Amostras foram então descontaminadas por dois diferentes tratamentos químicos (ácido citrico 10% e ácido etilenodiamino tetraacético- EDTA 24%) e terapia fotodinâmica (azul de metileno associado com LASER), ambos em 3 minutos com tempo de aplicação. No grupo controle, os implantes foram descontaminados com clorexidina 0.12% por 3 minutos. A área de descontaminação foi determinada no software Image J para análise das imagens de MEV. Depois da descontaminação, a adesão e proliferação da linhagem de células de osteosarcoma osteoblástica humana (Saos-2) em superfícies não contaminadas de implantes estéreis (controle; n: 1/período) e implantes descontaminados (n: 3/período/grupo) foram investigados. Células da Saos-2 [5x104] foram cultivadas sobre as superficies dos implantes e incubadas por 24 horas (ensaio de adesão) e 72 horas (ensaio de proliferação) e determinadas em imagens de MEV. Não foram encontradas diferenças significantes entre os implantes em relação a parâmetros de rugosidade, com exceção para Rv (SLA: 19.57±4.01 vs. OT: 8.36±7.91; p=0.0031). Houve variação na composição química dos implantes de acordo com o tratamento de superfície, com todos os grupos mostrando prevalência do Titânio. Houve maior ângulo de contato (análise de molhabilidade) para NT (hidrofóbico) e menor para ACQ (altamente hidrofílico; p<0.0001). Nanotite/Biomet 3i® mostrou porcentagem significativamente maior de área contaminada por bactérias (68.19% ± 8.63%; p=0.050; Kruskal Wallis/Dunn) que ACQ (57.32% ± 5.38%). Osseotite/Biomet 3i® resultou em significativa menor área contaminada remanescente (50.89% ± 9.12%) depois dos tratamentos de descontaminação. Foi observada maior adesão e proliferação de células Saos-2 em SLA após 24 (p= 0.0006; ANOVA/Tukey) e 72 horas (<0.001; ANOVA/Tukey). Os grupos descontaminados mostraram número significativamente menor de células aderidas às superfícies nos dois períodos de tempo comparativamente aos controles não contaminados (p < 0.005; ANOVA post hoc Sidak). Em relação aos métodos de descontaminação, não foram observadas diferenças no número de células aderidas aos implantes tratados por terapia fotodinâmica e agentes químicos comparados com clorexidina em 24 horas, mas os primeiros mostraram maior número de células aderidas depois de 72 horas. Esses achados sugeriram que as características de superfície influenciaram a contaminação bacteriana e a descontaminação de superfície; nenhum método de descontaminação é capaz de remover completamente a contaminação bacteriana, dificultando a adesão e proliferação celular. Esses achados poderiam explicar a variação de resultados clínicos nos métodos de descontaminação e obtenção de reosseointegração.
|
762 |
Caracterização do aço inoxidável austenítico UNS S31254 em meio de NaCI 0,11 mol L-1 visando seu emprego em implantes ortopédicos / Electrochemical characterization of UNS S31254 austenitic stainless steel in 0.11 mol L-1 NaCl medium in order to propose its application in orthopaedic implantsAfonso, Monica Luisa Chaves de Andrade 27 September 2006 (has links)
Foi feita a caracterização eletroquímica do aço inoxidável austenítico UNS S31254 em meio de NaCl 0,11 mol L-1 na ausência e presença de soro albumina bovina (BSA) visando seu emprego em implantes ortopédicos. Foram empregadas como técnicas: medidas de potencial de circuito aberto, curvas de polarização, cronoamperometria, EIE, XPS, MEV, EDS e EEO. O comportamento eletroquímico do aço 254 foi comparado com o de outros aços empregados em implantes ortopédicos (ISO 5832-9, ASTM F138, e AISI 316L) na ausência e presença de BSA. O aço 254 se mostrou semelhante ao ISO 5832-9: encontra-se passivado desde o potencial de corrosão até o de transpassivação; a presença de inclusões de óxidos de cálcio e alumínio no aço 254 foi considerada a responsável por um potencial de transpassivação 100 mV menos positivo do que o observado com o aço ISO 5832-9. Foi detectada. além de óxido de Cr(III), a presença de Mo na forma Mo(VI) no filme passivo do aço 254. A ação da BSA, ora passivante ora catalisadora, depende de sua concentração, da natureza do substrato metálico, e do potencial na interfase metal-solução. A BSA modifica o mecanismo de oxidação do aço 254 e inibe seletivamente a dissolução dos seus elementos constituintes, em particular, níquel e cromo. / The electrochemical characterization of UNS S31254 has been made in 0.11 mol L-1 NaCl medium in the absence and presence of bovine serum albumin (BSA) in order to propose its application in orthopaedic implants. The techniques employed were: open circuit potential measurements, polarization curves, chronoamperometry, EIS, XPS, SEM, EDS and EEO. The electrochemical behavior of 254 SS was compared to that observed for ISO 5832-9, ASTM F138 and AISI 316L stainless steels, used in orthopedic implants, in the absence and presence of BSA. 254 SS is similar to ISO 5832-9 SS: it is passivated on the potential range between the corrosion and the transpassivation potentials; the presence of calcium and aluminum oxides can be responsible for the shift of about 100 mV to less positive potentials on the transpassivation potential when compared to ISO 5832-9 SS. The presence of Mo(VI) was detected beside Cr(III) as passivating film for 254 SS. BSA action depends on its concentration, the nature of the metallic substract and on the potential in the metal-solution interphase. BSA changes the oxidation mechanism of 254 SS and promotes the selective dissolution of the elements particularly nickel and chromium.
|
763 |
Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro studyTunes, Fábio Sanches Magalhães 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
|
764 |
Avaliações histológica e histomorfométrica de implantes osseointegráveis de titânio com superfície anodizada e revestida por Ca e P / Histological and Histomorphometric analysis of Ti implants with surfaces modified by anodic spark deposition in Ca and PAlbuquerque, Gustavo Cavalcanti de 20 December 2010 (has links)
Estudos de modificações de superfície de implantes de Ti têm atraído a atenção dos pesquisadores por existir grande interesse em tratamentos que possam acelerar o processo fisiológico de reparo do tecido ósseo em contato com o Ti. Avaliações in vitro mostraram que superfícies de Ti obtidas por modificação físicoquímica como a anodização (anodic spark discharge ASD) podem representar uma boa alternativa para melhorar a osseointegração de implantes. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de mandíbula de cães a implantes osseointegráveis de Ti com superfície modificada por duplo ataque ácido (AE), por anodização em solução de íons cálcio e fosfato (ASD-AK) e anodização em solução de silício, cálcio e fosfato seguido por ataque alcalino em NaOH (SiB-Na). Para isso dez cães foram submetidos a exodontia dos pré-molares 12 semanas antes das instalação dos implantes. Os animais foram sacrificados no período de 5 e 8 semanas (cinco por período) e os segmentos ósseos contendo os implantes foram processados. Foram avaliados os efeitos dos tratamentos de superfície na (1) porcentagem de contato direto osso-implante, (2) formação óssea entre as roscas do implante e (3) formação óssea à distância da superfície do implante. Os resultados mostraram que todos os tratamentos (AE, ASD-AK e SiB-Na) permitiram formação óssea em contato direto e adjacente à superfície de Ti sem apresentar nenhum diferença qualitativa e quantitativa no padrão de reparo ósseo. Portanto, esses tratamentos deveriam ser avaliados clinicamente na reabilitação implanto-suportada de pacientes parcial ou totalmente edêntulos. / Surface modification of Ti have been attracted the attention of the researchers for existing great interest in treatments that can speed up the physiological process of repair of the bone contact. Aiming to improve the osseointegration of Ti implants several surface treatments have been proposed including those obtained by anodic spark deposition technique (anodic spark discharge ASD). This treatment allows to developing a thin and porous surface layer enriched with selected ions from the electrochemical solution. This study was designed to analyze bone repair adjacent to and in contact with Ti implants with surfaces modified by acid etching (AE) and anodic spark deposition (ASD). Surface modification of Ti implants was carried out by three methods: AE, ASD in calcium and phosphate solution (ASD-AK), and ASD in calcium, phosphate and silicon solution followed by alkali etching in NaOH (SiB-Na). Ten mongrel dogs were submitted to premolar extraction and after 12 weeks AE, BS, and SiB-Na self-screw Ti implants were placed into edentulous areas. Animals were killed at 3 and 8 weeks (five per period) and bone fragments with implants harvested and processed to obtain thin ground sections. Histomorphometric analysis was carried out to determine the bone-implant contact (BIC), bone area between threads (BABT), and bone area adjacent to threads (BAAT). The results had shown that all the treatments (AE, ASD-AK and SiB-Na) had allowed bone formation in direct and adjacent contact to the surface, without qualitative and quantitative difference in the standard of bone repair. Therefore, these surface treatments would have clinically to be evaluated in the implant-supported rehabilitation of total edentulous or patients partial.
|
765 |
Efeitos de diferentes doses de PTH sintético (1-34) sobre o tecido ósseo ao redor de implantes inseridos em ratos / Effect of different doses of synthetic PTH (1-34) on bone around implants inserted in ratsMafra, Carlos Eduardo Secco 26 February 2014 (has links)
O objetivo do presente estudo foi investigar se doses do hormônio sintético paratireoideano (PTH 1-34), mais baixas que as estudadas previamente apresentam um efeito osteoanabólico ao redor de implantes de titânio. Para isto, realizou-se um estudo paralelo, cego no qual foram utilizados 45 ratos Wistar machos adultos. Sob anestesia geral, todos os animais receberam em uma das tíbias, aleatoriamente escolhida, um implante de titânio comercialmente puro e superfície usinada (4.5 x 2.2 mm). Após a colocação dos implantes, os animais foram sorteados para receber um dos seguintes tratamentos: grupo 1: injeções subcutâneas de 40 g/Kg de PTH sintético (1-34) três vezes por semana (n=15); grupo 2: injeções subcutâneas de 2 g/kg de PTH sintético (1-34) três vezes por semana (n=15) e grupo 3: injeções subcutâneas do veículo utilizado para a dissolução do hormônio (n=15). 30 dias após a cirurgia os animais foram sacrificados, as peças contendo o implante e o osso circundante foram removidas e processadas histologicamente para cortes não descalcificados. As lâminas obtidas foram avaliadas em relação aos seguintes parâmetros histométricos, os quais foram expressos em porcentagem: (PTM) proporção de tecido mineralizado na região adjacente ao implante (500m lateralmente a superfície do implante e fora das roscas); (AO) preenchimento ósseo dentro dos limites das roscas de cada implante e (CD) extensão de tecido ósseo em contato direto com a superfície do implante. Os resultados do presente estudo mostraram que ambas as doses utilizadas influenciaram a região medular apenas para o parâmetro AO (P=0,0394). Já para a região cortical, ambas as concentrações de PTH (1-34) utilizadas (Grupos 1 e 2) influenciaram de maneira positiva todos os parâmetros investigados (PTM, AO e CD - p<0,05). Dentro dos limites deste estudo concluiu-se que o PTH (1-34) estimulou a formação óssea ao redor de implantes de titânio, mesmo em doses baixas. / The aim of this study was to investigate whether doses of synthetic parathyroid hormone (PTH 1-34), lower than the previously studied, have an osteoanabólic effect on bone around titanium implants. A blind parallel study was conducted and used 45 adult male Wistar rats. Under general anesthesia, all the animals received in a randomly chosen tibia a titanium implant (4.5 x 2.2 mm). After implant placement, the animals were randomized to receive one of the following treatments: group 1: subcutaneous injections of 40 g / kg of synthetic PTH (1 -34) three times per week (n=15); group 2 subcutaneous injections of 2 g / kg of synthetic PTH (1-34) three times per week (n = 15); group 3: vehicle injections required for hormone dissolution (n = 15). Thirty days after surgery, the animals were sacrificed and specimens containing the implant and the surrounding bone were removed and processed for histological non-decalcified sections. The sections obtained were evaluated according to the following histometric parameters (presented as percentage): proportion of mineralized tissue in the region adjacent to the implant (500m laterally to the implant surface and out of the threads (PTM), bone filling whithin the limits of the threads(AO) and bone-to-implant contact (BIC). For the cortical region, all parameters were positively affected by both hormone concentrations and Groups 1 and 2 presented similar results that were significantly higher than the results of control group (group3) (p < 0.05). Similar results were observed for the parameter AO in the cancellous region (p = 0.0394). Within the limits of this study, it can be concluded that PTH (1-34) stimulates bone formation around titanium implants, even at low doses
|
766 |
Influência de diferentes superfícies de titânio na adesão, proliferação e diferenciação de células semelhantes a osteoblastos de ratos (osteo-1) em culturas, na presença ou não da proteína morfogenética óssea recombinante-2 (rhBMP-2) / Influence of different titanium surfaces in the adhesion, proliferation and differentiation of rat osteoblast-like cells (osteo-1 culture), in the presence or nor of the recombinant bone morphogenetic protein (rhBMP-2)Cirano, Fabiano Ribeiro 03 December 2007 (has links)
Este estudo analisou a influência de diferentes superfícies de titânio na adesão, proliferação e diferenciação de células semelhantes a osteoblastos de rato (osteo-1) em culturas, na presença ou não da proteína morfogenética óssea recombinante-2 (rhBMP-2). As células osteo-1 foram cultivadas sobre as seguintes superfícies de titânio: 1. superfície lisa, 2. superfície desgastada com partículas de areia e condicionamento ácido (SLA) e 3. superfície desgastada com partículas de areia e condicionamento ácido sob proteção de nitrogênio e armazenadas em solução isotônica de cloreto de sódio (SLActive), na presença ou não de 20 ng/ml de rhBMP-2. Foram analisadas a adesão celular em 24 horas, o conteúdo total de proteínas, o conteúdo de colágeno e a atividade de fosfatase alcalina em 7, 14 e 21 dias e a formação de nódulos calcificados em 21 dias. Os resultados mostraram que a adesão não foi influenciada nem pelo tipo de superfície nem pelo tratamento com rhBMP-2 (p=0,0936). Quando relacionamos o conteúdo total de proteínas ao número total de células, percebemos que a proliferação não foi influenciada pelo tipo de superfície de titânio, porém a adição de rhBMP-2 levou a uma redução estatisticamente significante na superfície SLA aos 21 dias (p=0,0000). Em relação à diferenciação, pudemos observar que o tipo de superfície não influenciou o conteúdo total de proteínas, o conteúdo de colágeno e a formação de nódulos calcificados em quaisquer dos períodos analisados. A atividade de fosfatase alcalina somente foi influenciada pelo tipo de superfície aos 14 dias, onde o grupo C/SLAactive apresentou valores inferiores ao grupo C/Liso (p=0,0000). A adição de rhBMP-2 promoveu uma maior influência sobre o processo de diferenciação, levando a uma redução estatisticamente significante no conteúdo total de proteínas na superfície SLA aos 21 dias (p=0,0000), a um aumento estatisticamente significante no conteúdo de colágeno na superfície SLActive no período de 7 dias (p=0,0005) e a uma diminuição estatisticamente significante na atividade de fosfatase alcalina na superfície lisa nos períodos de 14 e 21 dias, na superfície SLA aos 14 dias e na superfície SLActive aos 21 dias (p=0,0000). Somente a formação de nódulos calcificados não sofreu influência da adição de rhBMP-2. / This study has analyzed the influence of different titanium surfaces in the adhesion, proliferation and differentiation of rat osteoblast-like cells (osteo-1 culture), in the presence or not, of the recombinant bone morphogenetic protein-2 (rhBMP-2). The osteo-1 cells were grown on the following titanium surfaces: 1. smooth surface; 2. coarse grit-blasted and acid-etched surface (SLA); and 3. coarse grit-blasted and acid-etched surface under nitrogen protection, and stored in sodium chloride isotonic solution (SLActive), in the presence or not, of 20 ng/ml of rhBMP-2. It was analyzed the cell adhesion in 24 hours, the total protein content, the collagen content, and the alkaline phosphatase in 7, 14 and 21-day periods, and also the formation of calcified nodules in 21 days. The results showed that the adhesion was neither influenced by the surface type, nor by the treatment with rhBMP-2 (p=0.0936). When we related the total protein content to the total number of cells, we noticed that the proliferation was not influenced by the titanium surface type; however, the addition of rhBMP-2 led to a statistically significant reduction on the SLA surface at 21 days (p=0.0000). Concerning the differentiation, we could observe that the surface type did not influence the total content of proteins, the collagen content and the formation of calcified nodules in any of the analyzed periods. The alkaline phosphatase activity was only influenced by the surface type at 14 days, where the group C/SLActive presented lower values than the group C/Smooth (p=0.0000). The addition of rhBMP- 2 promoted a bigger influence over the differentiation process, thus leading to a statistically significant reduction in the total protein content on the SLA surface at 21 days (p=0.0000), a statistically significant increase in the collagen content on the surface SLActive in the 7-day period (p=0.0005), a statistically significant reduction in the alkaline phosphatase activity on the smooth surface in the 14 and 21-day periods, on the SLA surface at 14 days, and on the SLActive surface at 21 days (p=0.0000). Only the formation of calcified nodules did not undergo influence of the rhBMP-2 addition.
|
767 |
"Análise quantitativa das regiões glabelar e espinha nasal anterior visando à colocação de implantes para retenção de prótese nasais" / Quantitative analysis of the glabellar and anterior nasal spine regions for the placement of implants for nasal prosthesis retentionSantos, Rodrigo Nogueira dos 02 December 2005 (has links)
Objetivos: Determinar a precisão das mensurações de dois pontos anatômicos craniométricos pré-estabelecidos, glabela e espinha nasal anterior, para verificar a possibilidade deles serem locais potenciais para a colocação de implantes, visando à retenção de próteses nasais. Métodos: Vinte e seis crânios secos de humanos, divididos em dois grupos iguais dos gêneros masculino e feminino, escaneados por meio de um aparelho tomógrafo espiral, de alta resolução, contínuo, com cortes axiais de 1 mm de espessura, produzidos com 1 mm de intervalo de reconstrução, por 2 segundos de tempo com filtro para tecido ósseo. As imagens obtidas foram armazenadas e transferidas para um workstation, contendo o programa de visualização e-film 1.5.3, para o processamento das imagens dos cortes axiais. A leitura destas mensurações foram realizadas independentemente por dois observadores em duas vezes cada um. Os dados obtidos foram submetidos à análise estatística, com duas variáveis, glabela e espinha nasal anterior, levando-se em consideração um fator de variação: gênero masculino e feminino. Resultados: Os valores médios obtidos para a espinha nasal anterior foram de 12,04 mm no gênero masculino e 11,62 mm no gênero feminino e, para a glabela, de 4,06 mm no gênero masculino e 3,60 no gênero feminino. Conclusões: Os pontos craniométricos avaliados apresentaram valores indicativos da possibilidade de serem utilizados para a colocação de implantes, principalmente, a espinha nasal anterior. Quanto ao gênero, na espinha nasal anterior não houve diferença entre os sexos, e na glabela houve uma pequena diferença estatisticamente insignificante. / Objectives: To determine the precision of the measurements of two preestablished craniometric anatomical points, the glabella and anterior nasal spine, in order to verify their possibility as potential locations for placing implants aimed at the retention of nasal prostheses. Methods: Twenty-six dry human crania (13 male and 13 female) were scanned by means of continuous high-resolution spiral tomography equipment, with axial slices of 1 mm in thickness that were produced with reconstruction intervals of 1mm and a record length of 2 seconds, using a filter for bone tissue. The images obtained were stored and transferred to a workstation containing the e-film 1.5.3 imaging software, to process the axial slice images. The readings of these measurements were done independently by two observers, twice for each measurement. The data obtained were submitted by means of statistical analysis using two variables (glabella and anterior nasal spine) and taking into consideration one variation factor (male or female gender). Results: The mean values obtained for the anterior nasal spine were 12.04 mm for males and 11.62 mm for females. For the glabella they were 4.06 mm for males and 3.60 for females. Conclusions: The craniometric points evaluated presented values that indicated the possibility that they could be utilized for placing implants , particularly the anterior nasal spine. With regard to gender, there was no difference for the anterior nasal spine and a small, statistically non-significant difference for the glabella.
|
768 |
Avaliação do índice de sucesso de osseointegração em reabilitações tipo protocolo : análise retrospectiva em Cursos de Especialização em Implantodontia /Monteiro, Ricardo Luís Prado. January 2018 (has links)
Orientador: Fernando Vagner Raldi / Banca: Rodrigo Dias Nascimento / Banca: Fábio da Silva Matuda / Resumo: O objetivo deste trabalho foi avaliar o índice de sucesso de Osseointegração por meio de uma revisão retrospectiva, dos prontuários de pacientes que receberam tratamento cirúrgico para a colocação de implantes em reabilitações totais do tipo protocolos maxilares e mandibulares, com carga tardia, realizados em cursos de pós-graduação em Implantodontia no Sindicato de Santo André - SP, ABO Regional de Barra Mansa - RJ e ABO Regional de Volta Redonda - RJ, no período de 2007 a 2013. Foram avaliados 2.208 implantes (Implacil®- São Paulo, Brasil), instalados em 398 pacientes (231 mulheres e 167 homens), com 1.323 implantes mandibulares e 885 implantes maxilares, com idade média de 59.2 anos, analisando: gênero, arcadas, tipo de implante, diâmetro e insucessos, no período de Osseointegração. Os resultados mostraram índice de insucesso em 19 mulheres (8%) e 11 homens (6,5%) com 36 implantes perdidos (1,7%), divididos em 18 perdas mandibulares (1,4%) e 18 perdas maxilares (2,1%). Com base na literatura, podemos concluir que o índice de sucesso de 98,3% obtido no estudo em cursos de especialização em implantodontia por nós ministrados foi satisfatório / Abstract : The objective of this study was to evaluate the success rate of Osseointegration by means of a retrospective review of the medical records of patients who received surgical treatment for the placement of implants in maxillary and mandibular late loading mandibular restorations performed in courses of post-graduation in Implant Dentistry at the São André Union - SP, ABO Regional of Barra Mansa - RJ and ABO Regional of Volta Redonda - RJ, from 2007 to 2013. Two hundred and twenty implants (Implacil®-São Paulo, Brazil) were evaluated, (231 women and 167 men), with 1,323 mandibular implants and 885 maxillary implants, with a mean age of 59.2 years, analyzing: gender, arches, type of implant, diameter and failures in the period of Osseointegration. The results showed failure rates in 19 women (8%) and 11 men (6.5%) with 36 implants lost (1.7%), divided into 18 mandibular losses (1.4%) and 18 maxillary losses (2,1%). Based on the literature, we can conclude that the success rate of 98.3% obtained in the study in specialization courses in implantology given by us was satisfactory / Mestre
|
769 |
Reabilitação de pacientes com implante coclear utilizando uma nova abordagem na análise da percepção auditivaRODRIGUES, Ana Paula Sirotheau Corrêa 28 March 2018 (has links)
Submitted by JACIARA CRISTINA ALMEIDA DO AMARAL (jaciaramaral@ufpa.br) on 2018-05-15T14:42:40Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação de Mestrado - Ana Paula Sirotheau Corrêa Rodrigues.pdf: 2064468 bytes, checksum: 829587bab68aad637db9e04105b07574 (MD5) / Approved for entry into archive by JACIARA CRISTINA ALMEIDA DO AMARAL (jaciaramaral@ufpa.br) on 2018-05-15T14:45:09Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação de Mestrado - Ana Paula Sirotheau Corrêa Rodrigues.pdf: 2064468 bytes, checksum: 829587bab68aad637db9e04105b07574 (MD5) / Made available in DSpace on 2018-05-15T14:45:09Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação de Mestrado - Ana Paula Sirotheau Corrêa Rodrigues.pdf: 2064468 bytes, checksum: 829587bab68aad637db9e04105b07574 (MD5)
Previous issue date: 2018-03-28 / A comunicação é a forma que temos de interagir com o mundo, essa comunicação pode ser verbal ou não verbal. Para o progresso satisfatório da comunicação oral é necessário que a via auditiva, desde a porção central até a porção periférica esteja funcionando adequadamente. Quando ocorre alguma alteração na via auditiva, é necessário o uso de dispositivos que auxiliem a percepção do som, dentre estes instrumentos destacamos o implante coclear, porém, para o aproveitamento adequado deste recurso, é imprescindível uma reabilitação eficiente. Objetivo: Desenvolver um simulador de implante coclear com a finalidade de proporcionar ao reabilitador identificar o estímulo recebido pelo deficiente auditivo, e dessa forma atuar nas programações das sessões de reabilitação, para que os sons possam ser detectados corretamente, favorecendo o desenvolvimento ou a manutenção da comunicação oral. Métodos: Para o desenvolvimento do estudo foram formados 3 grupos de indivíduos: o primeiro grupo foi constituído por 6 pacientes implantados que receberam como estimulo o som puro. Os grupos 2 e 3 foram compostos por normo-ouvintes que receberam os sons filtrados pelo simulador de implante coclear, o grupo 2 com 22 indivíduos recebeu os sons filtrados para 22 canais ativados (100%) e o grupo 3 percebeu sons filtrados com 17 canais ativados (77%), correspondendo ao número de canais ativados em um implante coclear. Todos os participantes foram submetidos a sessões com estímulos audiovisuais em um software executado em um computador com tela sensível ao toque. Os estímulos são 124 palavras extraídas de uma lista utilizada no exame de logoaudiometria, sendo 16 trissílabos, 46 dissílabos e 62 monossílabos. As palavras trissílabas foram geradas sinteticamente e as demais gravadas em voz feminina de fonoaudióloga. Resultados: Observou-se que todos os grupos apresentaram maior dificuldade na detecção de monossílabos, onde o período de latência foi aumentado e ocorreram mais erros para percepção do som, isso deve-se a diminuição da pista auditiva. E, portanto, se houver um tratamento de reabilitação individualizado, acredita-se que o desenvolvimento do deficiente auditivo implantado decorra de uma forma mais eficiente. / Communication is the way we have to interact with the world, this communication can be verbal or nonverbal. For the satisfactory progress of oral communication, it is necessary that the auditory pathway, from the central portion to the peripheral portion, is functioning properly. When there is a change in the auditory pathway, it is necessary to use devices that aid the perception of sound, among these instruments we highlight the cochlear implant, but for the proper use of this resource, an efficient rehabilitation is essential. Objective: To develop a cochlear implant simulator with the purpose of enabling the rehabilitator to identify the stimulus received by the hearing impaired, and thus to act in the schedules of the rehabilitation sessions, so that the sounds can be detected correctly, favoring the development or maintenance of the oral communication. Methods: For the development of the study, 3 groups of individuals were formed: the first group consisted of 6 implanted patients who received as pure sound stimulus. Groups 2 and 3 were composed of normo-listeners who received the sounds filtered by the cochlear implant simulator; group 2 with 22 individuals received filtered sounds for 22 activated channels (100%) and group 3 perceived filtered sounds with 17 channels activated (77%), corresponding to the number of channels activated in a cochlear implant. All participants were submitted to sessions with audiovisual stimuli in software running on a computer with a touch screen. The stimuli are 124 words extracted from a list used in the logoaudiometry exam, being 16 trisyllables, 46 disyllables and 62 monosyllables. The trisyllables words were generated synthetically and the others recorded in female voice of speech therapist. Results: It was observed that all groups presented greater difficulty in the detection of monosyllables, where the latency period was increased, and more errors occurred for sound perception, this is due to the reduction of the auditory track. Therefore, if there is an individualized rehabilitation treatment, it is believed that the development of the implanted hearing impaired is more efficient.
|
770 |
Estudo comparativo do vidro bioativo e osso autógeno em aumento do assoalho de seios maxilares de humanos /Pereira, Rodrigo dos Santos. January 2016 (has links)
Orientador: Eduardo Hochuli-Vieira / Banca: Idelmo Rangel Garcia Júnior / Banca: Leonardo Perez Faverani / Banca: Nicolas Homsi / Banca: Joel Ferreira Santiago Junior / Resumo: A deficiência óssea vertical do seio maxilar impossibilita a instalação de implantes dentais necessários para a reabilitação protética contudo, técnicas cirúrgicas para a elevação da membrana sinusal e o uso dos biomateriais para enxertia óssea permitiram alterar esta condição. O ósseo autógeno é considerado o mais previsível e o padrão ouro para tal finalidade porém, biomateriais como o vidro bioativo, amplamente utilizado na odontologia, permitem substituí-lo. O objetivo deste estudo foi avaliar formação óssea, o comportamento celular e a taxa de reabsorção do vidro bioativo em 2 proporções: puro (grupo 1); adicionado ao osso autógeno 1:1 (grupo 2), comparando com o osso autógeno (grupo 3) em seios maxilares de humanos. Com 15 dias de operados os pacientes realizaram um tomografia computadorizada (TC) cone beam para determinar o volume inicial do enxerto (T1). Após 6 meses uma nova TC foi realizada determinando o volume ósseo final (T2) e também, a coleta das biópsias com a instalação simultânea de implantes dentais. As amostras foram divididas em 3 áreas: leito, intermediária e apical onde foram avaliadas a histomorfometria e imunomarcações para Runx2, VEGF, osteocalcina e TRAP. No grupo 1 os resultados foram de 42.6%, 44.5% e 48% de formação óssea no leito, intermediária e apical respectivamente. No grupo 2 as taxas encontradas foram de 36.6% no leito, 33.2% na intermediária e 45.8% na apical. No grupo 3 foi de 34.4% para o leito, 35.0 na intermediária e 42.0% na apical. (p>0.05) Os 3 grupos apresentaram-se com comportamento semelhante nas imunomarcações realizadas mostrando estar maturado e calcificado o suficiente para receber implantes dentais. As taxas de reabsorção também mostraram-se semelhantes com 44.2% para o grupo 1, 37.9% para o grupo 2 e 45.7% no grupo 3. (p>0.05) Assim, podemos concluir que o vidro bioativo possui resultados equiparados ao osso autógeno / Abstract: Vertical bone deficit due maxillary sinus pneumatization forbid the dental implants placement required for prosthetic rehabilitation however, surgical techniques to elevate maxillary sinus membrane and studies about biomaterials, allows repair these situation. Autogenous bone graft is considered the most predictable and the gold standard for this nevertheless, biomaterials as bioactive glass, has been widely used in dental surgery and allows substitute it. The aim of this study was evaluate the bone formation, the cellular behavior and the resorption rates of bioactive glass in 2 proportions: pure (group 1); add to autogenous bone graft (group 3), comparing then with autogenous bone graft in human maxillary sinus. Post-operative cone beam computed tomography (CT) was used to measure the initial graft volume after 15 days (T1). Six months later, another CT was performed to evaluate the final graft volume (T2) and determine the graft resorption rate and the harvest of biopsies with dental implants placement simultaneously. The samples were divided in 3 areas: bed, intermediately and apical which were evaluated to histomorphometric and immunostaining to Runx2, VEGF, osteocalcin and TRAP. In group 1 the bone formation were 42.6%, 44.5 and 48.0% for bed, intermediately and apical respectively. In group 2 the rates were 36.6% in bed, 33.2% in intermediately and 45.8% in apical. In group 3 were 34.4% in bed, 35.0% in intermediately and 42.0% in apical. (p>0.05) the 3 groups had the same behavior for the 4 proteins showing be matured and calcified to receive dental implants. The resorption rates were similar for the 3 groups with 44.2% % for group 1, 37.9% for group 2 and 45.7% for group 3. (p>0.05) In conclusion, the bioactive glass is a good substitute to autogenous bone graft in both proportions evaluated / Doutor
|
Page generated in 0.0498 seconds