• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Análise histomorfométrica de implantes hidrofóbicos e hidrofílicos: estudo experimental em coelhos / Comparative histomorphometric analysis of hydrophobic and hydrophilic implants: an experimental study in rabbits

Cunha, Verena Souza da 03 June 2015 (has links)
O íntimo contato entre osso e implante é considerado um pré-requisito fundamental para o sucesso dos implantes dentários, condição esta conhecida como osseointegração. Devido a isto, um grande número de pesquisas com tratamentos de superfícies de implantes vem sendo desenvolvido por várias empresas nos últimos anos, visando acelerar esse fenômeno. O objetivo deste trabalho é avaliar histomorfometricamente o percentual de contato osso-implante (BIC) e área de osso novo (BA) entre implantes de tratamento de superfície Neoporos (GC - hidrofóbico) e implantes com energia de superfície molhada Acqua (GE - hidrofílicos). Foram utilizados 15 coelhos da raça new zealand, que receberam 30 implantes divididos em cada lado de suas tíbias direita e esquerda, ambos de titânio comercialmente puro grau IV com 3.5x8mm de dimensão, sendo ao final de 15 dias, a região dos implantes coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados, embora dois implantes do grupo Esm tenham sido excluídos da pesquisa devido à instalação ter ocorrido dentro do canal medular e terem obtido tecido necrosado, não cumprindo as características de osseointegração. Para análise dos dados estatísticos, utilizou-se o teste t de Students para amostras independents e teste Mann-Whitney Rank Sum com nível de significância de p<0.05. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos para a análise de BIC. O grupo GC apresentou a média de 42.9% de BIC, ligeiramente menor que o grupo GE, que apresentou 49.3% de média. Já para o teste BA houve diferenças de 15%, em que o grupo GC apresentou 58.6% e o grupo GE, 74.4%. A conclusão é que há, ainda, necessidade de maiores estudos a cerca do referido tema. / The near contact between bone and implant is considered an essential pre-requisite for the success of dental implants, a condition known as osseointegration. Due to it, a great amount of researches on implants surface treatments has been developed by several companies in recent years to accelerate the phenomenon of osseointegration. The aim of the present study is to evaluate histomorphometrically the percentage of bone-implants contact (BIC) and the area of new bone (BA) between implants with surfaces treatment Neoporos (GC - hydrophobic) and implants with wets surface energy Acqua (GE - hydrophilic). It was used fifteen (n=15) New Zealand rabbits, which received thirty implants installed dividing them between its right and left tibias. Implants were commercially pure titanium grade IV with 3.5x8mm dimension. After fifteen days, the implants area were collected and processed histologically in order to obtain not demineralized tissue sections. For statistical data analysis, it was used the t test for independents samples and Mann-Whitney Rank Sum test. The significance level was p<0.05. Results showed no statistical significant difference between groups for BIC analysis. The control group showed a mean of 42.9% of BIC, slightly lower than the GE group, which showed a mean of 49.3%. For BA test, there was a significant difference of more than 15% in the control group (58.6% for the GC group and 74.4% for GE group). It was concluded that futher studies is needed on this topic of osseointegration and hydrophobic /hydrophilic implants.
212

Avaliação da resistência e módulo de elasticidade de osso mineralizado e desmineralizado pelos testes de microtração / Evaluation of the resistance and modulus of elasticity of bone mineralized and desmineralized for the tests of microtensile

Sanada, Jefferson Tomio 28 March 2007 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos. A regeneração é feita através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Estes procedimentos são realizados através da utilização de enxertos autógenos, alógenos, aloplásticos ou xenogênicos, tendo cada um suas características e indicações. Com o desenvolvimento dos implantes osseointegrados, viu-se a necessidade de manter uma boa quantidade e qualidade óssea. Este projeto tem como objetivo avaliar a resistência a tração e módulo de elasticidade do osso mineralizado e desmineralizado de calvária de ratos, a fim de determinar padrões iniciais (máximos e mínimos) para comparações com possíveis biomateriais de preenchimento de osteoindução e osteocondução. Foram utilizados 24 animais divididos em 2 grupos. O grupo 1 (n=12): módulo de elasticidade sendo que utilizaremos as duas parietais do animal, possibilitando 24 espécimes, subdividido em mineralizado (n=12) e desmineralizado (n=12). O grupo 2 (n=12): microtração, sendo que 12 hemicalvária foram utilizado para o sub-grupo desmineralizado e as outras 12 hemicalvária para o sub-grupo mineralizado. Após a morte dos animais, os espécimes serão coletados e tratados de acordo com o subgrupo (mineralizado e desmineralizado). Os testes foram realizados numa máquina de teste universal (Vitrodyme, V1000). As médias de resistência a tração do mineralizado foi 129,814 ± 34,921 MPa e o desmineralizado foi 18,547 ± 3,682 MPa. Para o módulo de elasticidade obtivemos os valores de 1377,792 ± 208,331 MPa para o grupo mineralizado e 49,669 ± 11,204 MPa para o grupo desmineralizado, ao compararmos o módulo de elasticidade e resistência a tração entre os subgrupo desmineralizado e mineralizado observa-se uma diferença estatisticamente significante para o grupo mineralizado (p<0,001). Conclui-se que o teste de microtração pode ser utilizado para avaliar as propriedades mecânicas nesse modelo experimental biológico. / The loss of the alveolar bone as resulted of periodontal illness or second to the surgery is sources of innumerable complications for the surgeons dentists, and the solution for such problem if it bases on regenerative procedures. Regeneration is made through bone grafts that establish one scaffold for the tecidual repairing, increasing bone fabrics in the resultant defects of trauma or surgeries, filling the alveolous after extraction to preserve the height and thickness of the alveolar rigde and being increased and/or reconstructing the alveolar rigde. These procedures are carried through the use of autogenous, alografts, aloplastic or xenogenics grafts, having each one its characteristics and indications. With the development of the osseointegrated implants, it was seen necessity to keep a good amount and bone quality. This project has as objective to evaluate the resistance the traction and modulus of elasticity of the mineralized bone and desmineralized.of calvarium of rats, similar to determine initial standards (maximum and minimum) for comparisons with possible biomateriais of fulfilling of osteoinduction and osteoconduction. 24 animals divided in 2 groups had been used. Group 1 (n=12): modulus of elasticity being that we will use the two parietals of the animal, having made possible 24 specimens, subdivided in mineralized (n=12) and desmineralized (n=12). Group 2 (n=12): microtraction, being that 12 hemi-calvarium had been used for 12 the desmineralized sub-group and the others hemi-calvarium for the mineralized sub-group. After the death of the animals, the specimens will be collected and treated in accordance with the sub-group (mineralized and desmineralized). The tests had been carried through in a machine of universal test (Vitrodyme, V1000). The resistance averages the traction of the mineralized one was mineralized 129,814 ± 34.921 MPa and the desmineralized one was 18,547 ± 3,682 MPa. For the modulus of elasticity we got values of 1377,792 ± 208.331 MPa for the mineralized group and 49,669 ± 11,204 MPa for the desmineralized group, when comparing the resistance and modulus of elasticity the traction between the desmineralized and mineralized sub-group observes a estatistical significant difference for the mineralized group (p<0,001). Concluded that the microtraction test can be used to evaluate the mechanical properties in this biological experimental model.
213

Avaliação de próteses metalocerâmicas unitárias implantossuportadas carregadas imediatamente na região posterior: estudo prospectivo de 6 meses / Evaluation of immediately loaded implant-supported metal ceramic crowns in the posterior region: prospective 6 months follow-up study

Machado, Camila Moreira 06 August 2018 (has links)
O objetivo deste estudo clínico prospectivo foi avaliar próteses metalocerâmicas unitárias implantossuportadas imediatamente carregadas na região posterior, instaladas com contato oclusal em máxima intercuspidação. Dezenove pacientes com perdas unitárias posteriores foram selecionados para receber implantes unitários imediatamente carregados com coroas metalocerâmicas. Todos os implantes foram inseridos com torque de inserção mínimo de 32 N.cm. e as coroas foram instaladas 4 dias após a instalação dos implantes. Os parâmetros avaliados foram: (1) sobrevida dos implantes, (2) tecido mole peri-implantar (índice de placa modificado - IPM, profundidade de sondagem - PS, índice de sangramento periimplantar - ISP e nível de inserção relativo - NIR) (3) prótese (Critério USPHS modificado), (4) avaliação radiográfica (perda óssea peri-implantar - POP) e (5) correlação do torque de inserção com perda óssea peri-implantar. Os períodos de avaliação foram: 9 dias (T1), 30 dias (T2) e 6 meses após a instalação do implante (T3). Concordância inter-examinadores (CIC) foi calculada para todos os parâmetros avaliados. A taxa de sucesso dos implantes foi de 100%; a taxa de sucesso da prótese foi de 89,5%, sendo observadas 2 complicações relacionadas com afrouxamento dos parafusos protéticos. As médias do IPM, PS, ISP NIR foram respectivamente: 0,21 ± 0,63, 1,71 ± 0,45, 0,53 ± 0,77, 10,56 ± 1,19, 1,54 ± 0,35 no tempo T2 e 0, 0, 1,36 ± 0,37, 10,55 ± 0,97 no tempo T3. Na comparação dos tempos, somente PS e ISP diminuíram significantemente de T2 para T3 (p = 0,006 e p = 0,015, respectivamente). As médias do nível ósseo peri-implantar nos tempos T1 e T3 foram de 1,54 ± 0,35 e 0,47 ± 0,76, respectivamente, com diferenças estatisticamente significantes encontradas entre os dois períodos de avaliação. CIC foi considerado excelente para todos os parâmetros avaliados ( 0,75). Dentro das limitações do estudo, os resultados sugerem que a carga imediata de implantes unitários posteriores restaurados com coroas metalocerâmicas com contato oclusal em máxima intercuspidação é uma opção viável de tratamento. Entretanto, pesquisas futuras devem ser conduzidas para a validação de tal protocolo a médio/longo prazos. / The purpose of this prospective clinical study was to evaluate implant-supported metal ceramic crowns immediately loaded in the posterior region, installed with occlusal contact at maximum intercuspation. Nineteen patients with posterior singleunit edentulous spaces were selected to receive implants immediately loaded with metal ceramic crowns. All implants were inserted with minimum insertion torque of 32 N.cm. and crowns were installed 4 days after implantation. The parameters evaluated were: (1) survival of the implants; (2) peri-implant soft tissue (modified plaque index - MPI and probing depth PD, peri-implant bleeding index PBI and relative insertion level RIL; (3) prostheses (modified USPHS criteria); (4) radiographic evaluation (peri-implant bone loss PBL) and (5) insertion torque correlation with peri-implant bone loss. The evaluation periods were: 9 days (T1), 30 days (T2) and 6 months after implant placement (T3). Inter-examiner agreement (IEA) was calculated for all parameters. The success rate of implants was 100%; the success rate of the prostheses was 89.5%, with 2 complications related to loosening of the prosthetic screws. The means of the MPI, PD, PBI, RIL were, respectively: 0.21 ± 0.63, 1.71 ± 0.45, 0.53 ± 0.77, 10.56 ± 1.19, 1.54 ± 0, 35 at T2 and 0, 0, 1.36 ± 0.37, 10.55 ± 0.97 at T3. In the comparison of evaluation time points, only PD and PBI decreased significantly from T2 to T3 (p = 0.006 and p = 0.015, respectively). Peri-implant bone level means at T1 and T3 times were: 1.54 ± 0.35 e 0.47 ± 0.76, respectively, with statistically significant differences between the two evaluation time points. IEA was considered excellent for all evaluated parameters ( 0,75). Within the limitations of the study, the results suggest that the immediate loading of posterior single implants restored with metal ceramic crowns with occlusal contact in maximal intercuspation is a viable treatment option. However, future research should be conducted to validate this protocol in the medium/long term.
214

Influência do desing, tratamento de superfície e densidade do substrato na estabilidade primária de implantes odontológicos. Análise por meio de torque de inserção, resistência ao arrancamento e freqüência de ressonância / Influence of the desing, surface treatment and substrate density on the primary stability of dental implants. Analysis using insertion torque, pull-out strength and resonance frequency.

Oliscovicz, Nathalia Ferraz 14 December 2011 (has links)
A grande variedade de modelos de implantes disponíveis no mercado, assim como a variabilidade óssea nos pacientes, torna cada vez mais difícil a seleção do implante que permita obter uma maior estabilidade primária, fator essencial para osseointegração. O objetivo desse trabalho foi avaliar a influência do formato e tratamento de superfície de implantes, assim como do substrato utilizado, na estabilidade primária; aferida por meio de ensaios de desempenho e freqüência de ressonância. Foram utilizados 32 implantes Conexão®: 8 implantes cilíndricos hexágono externo sem tratamento de superfície (MS), 8 cilíndricos hexágono externo com tratamento Porous duplo (MP), 8 cilíndricos hexágono interno com tratamento Porous (CA), 8 cônicos sem tratamento (CC); todos com 11,5 mm de comprimento, e 3,75 mm de diâmetro para cilíndricos e 3,5 mm para os cônicos. Foram inseridos em diferentes substratos: osso de costela suína; osso artificial de poliuretana Synbone©; poliuretana Nacional® em três densidades - 15, 20 e 40 PCF; e madeira pinus. Para o ensaio de desempenho foi quantificado o torque de inserção com o torquímetro digital Mackena®, e a força de arrancamento por meio de força axial de tração com célula de carga de 200 kg, realizada na Máquina Universal de Ensaios Emic® DL-10000, e Software Tesc 3.13. A análise da freqüência de ressonância foi realizada com o aparelho Osstell Mentor®. Para obtenção dos resultados estes receberam tratamento estatístico ANOVA e Teste de Tukey com nível de significância a 5%. Ao analisar o torque de inserção, implantes com tratamento de superfície não foram diferentes estatisticamente do usinados, assim como os implantes cilíndricos não tiveram diferença estatística com os cônicos em todos os substratos (P>0,05), com exceção da poliuretana Synbone©, onde os cônicos apresentaram a menor média (4.45 ± 0.82) e tiveram diferença estatistica com os cilíndricos, hexágono externo (MP= 11.39 ± 0.76; MS= 10.34 ± 1.68), e interno (12.18 ± 3.78). No osso suíno, na poliuretana Nacional® de 15 PCF e na madeira, os implantes cônicos mostraram um melhor desempenho que nos outros substratos. Da mesma forma que no torque de inserção, em relação à força máxima de arrancamento, implantes tratados e usinados, assim como cônicos e cilíndricos, não tiveram diferença estatística (P>0,05), em todos os substratos; implantes cônicos só não apresentaram menores médias de força de arrancamento em matérias menos densos - osso suíno (138.19 ± 57.41 N), poliueretana Nacional® de 15 (209.57 ± 9.60 N) e 20 PCF(206.57 ± 31.51 N); e implantes cilindricos hexágono interno mostraram a maior média numérica em todos os materiais de inserção. Os valores de freqüência de ressonância mostraram que, apesar dos implantes com tratamento de superfície apresentarem maior média de ISQ que os implantes usinados em todos os substratos, estes não apresentaram diferença estatística entre si (P>0,05), com exceção da inserção na poliuretana Nacional de 20 PCF. Pôde-se concluir que, tanto o formato, como o tratamento de superfície dos implantes não influenciaram nas análises realizadas, entretanto, o substrato utilizado e sua densidade tiveram uma maior influência nos resultados obtidos. / The great variety of implant models available in the market, as well as the variability of patients bones, makes the selection of the implant that allows greatest primary stability, an essential factor for osseointegration, increasingly difficult. The aim of this study was to evaluate the influence of the format and surface treatment of implants, as well as the substrate used in primary stability; verified through resonance frequency and performance tests. 32 Conexão® implants were used: 8 cylindrical external hexagon implants without surface treatment (MS), 8 cylindrical external hexagon implants with double Porous treatment (MP), 8 cylindrical internal hexagon implants with Porous treatment (CA), and 8 tapered implants without treatment (CC). All had a length of 11.5 mm, while the cylindrical ones had a of diameter 3.75 mm compared with 3.5 mm for the tapered ones. They were inserted in different substrates: pig rib bone; artificial bone made from polyurethane Synbone©; Nacional® polyurethane in three densities - 15, 20 and 40 PCF; and pinus wood. For the performance test the insertion torque (N.cm) was quantified using the digital Mackena® torque meter, and the pull-out force (N) by means of axial traction force with a 200 kg load cell, carried out in the Emic® DL-10000 Universal Test Machine and the Tesc 3.13 software. The analysis of the resonance frequency (ISQ) was carried out with the Osstell Mentor® device. To obtain the results the ANOVA and Tukey statistical tests were used with a level of significance 5%. When analyzing the insertion torque, implants with surface treatment were not statistically different from the machined ones, nor did the cylindrical implants have any statistical difference from the tapered ones in all the substrates (P> 0.05), with exception of polyurethane Synbone©, where the tapered ones had a lower average (4.45 ± 0.82) and a statistical difference from the external hexagon (MP= 11.39 ± 0.76; 10.34 MS= ± 1.68), and internal hexagon (12.18 ± 3.78) cylindrical ones. In the pig bone, the 15 PCF Nacional® polyurethane and the wood tapered implants had a better performance that in the other substrate. Similar to the insertion torque, treated and machined implants, and tapered and cylindrical, did not have any statistical difference (P>0.05) in all the substrates; tapered implants only did not have a lower average of pull-out except in less dense substrates pig bone (138.19 ± 57.41 N), 15 Nacional® polyurethane (209.57 ± 9.60 N) and 20 PCF (206.57 ± 31.51 N). Internal cylindrical hexagon implants had the highest numerical average of all the inserted materials. The resonance frequency values showed that although the implants with surface treatment had a greater average ISQ that the machined implants in all the substrates, there was no statistical difference between them (P> 0.05), with the exception of the insertion of 20 PCF Nacional® polyurethane. It can be concluded that both the format and surface treatment of implants did not influence the analyses, however, the substrate used and their densities had a bigger influence on the results obtained.
215

Análise das características microscópicas do tecido peri-implantar em diferentes tipos de conexão protética em implantes / Comparative analysis of peri-implant soft tissue microscopic characteristics between two types of implant-prosthetic connections

Castro, Daniel Sartorelli Marques de 21 June 2007 (has links)
As características microscópicas do tecido peri-implantar ao redor de diferentes tipos de interface protética para implantes foram avaliadas por meio de análise histológica, 10 pacientes portadores de prótese sobre implantes do tipo protocolo foram selecionados com base nos critérios de inclusão e divididos em dois grupos, com o grupo I formado por cinco pacientes portadores de implantes com interface do tipo hexágono externo e o grupo II formado por cinco pacientes com implantes com interface do tipo cone morse. Foram coletadas amostras de tecido gengival que estava em contato direto com o componente protético através de um procedimento cirúrgico, sendo coletada uma amostra de cada paciente, todas as amostras foram armazenadas em frascos contendo formalina a 10% e enviadas ao laboratório para a realização da análise. Na análise foram observados o grau de organização tecidual, presença e intensidade da inflamação e o grau de fibrosamento. As cinco amostras do grupo I apresentavam hiperplasia do epitélio, sendo todas classificadas como grau 2, todas mantinham sua integridade, sendo classificadas como preservadas, nenhuma das amostras deste grupo apresentavam ataque de células inflamatórias ao epitélio. Na análise do tecido conjuntivo, quatro amostras deste grupo apresentavam-se normais, sem a presença de inflamação, apenas uma das amostras apresentava sinais de inflamação, sendo a mesma classificada como moderada, todas as amostras apresentavam seu conjuntivo organizado, avaliando o grau de fibrosamento, duas amostras foram classificadas como grau 3, duas como grau 2 e uma amostra como grau 1, uma amostra deste grupo possuía fragmentos de cemento radicular envolto por fibras colágenas. No grupo II, quatro amostras apresentavam hiperplasia do epitélio, sendo classificadas como grau 2, apenas uma amostra encontrava-se livre de hiperplasia, quando foi avaliada a integridade do epitélio, três amostras foram classificadas como preservado e duas classificadas como desorganizadas,com a presença de células inflamatórias no interior do epitélio. Três amostras deste grupo apresentavam ataque de células inflamatórias ao epitélio. Na análise do tecido conjuntivo, todas as amostras foram classificadas como organizadas, com quatro das amostras apresentando sinais de inflamação, com intensidade classificada como grau 3 em duas amostras e como grau 2 em outras duas amostras, apenas uma amostra foi classificada livre de inflamação. Foram encontrados corpúsculos hialinos de Russel em três amostras. Avaliando o grau de fibrosamento, três amostras foram classificadas como grau 2 e duas como grau 3, foram encontrados fragmentos de cemento radicular em uma das amostras deste grupo. Na análise estatística não foram encontradas diferenças estatisticamente significantes para as variáveis hiperplasia, fibrosamento e intensidade da inflamação quando avaliadas separadamente, quando a interação das três variáveis foi avaliada, também não foram encontradas diferenças estatisticamente significantes, tendo os dois grupos apresentado resultados muito próximos. Com base nos resultados obtidos neste estudo, não foi possível afirmar que a presente metodologia permite estabelecer que um sistema de implante pode fornecer uma melhor condição ao tecido peri-implantar ao seu redor quando comparado ao outro sistema. / The microscopic characteristics of the peri-implant soft tissue around different types of prosthetic interface for implants has been evaluated by means of histological analysis, 10 patients carrying implant supported bridges has been selected on the basis of the inclusion criteria and divided in two groups, with group I formed by five patients with external hexagon interface type implants and group II formed by five patients with morse taper interface type implants. Gingival soft tissue samples that were in direct contact with prosthetic component have been collected through a surgical procedure, being a sample of each patient, all the samples had been stored in bottles containing 10% formaldehyde and sent to the laboratory for the accomplishment of the analysis. In the analysis, the degree of tissue organization, presence and intensity of the inflammation and the degree of fibrosity has been observed. The five samples of group I presented hyperplasia of the epithelium, being all classified as degree 2, all kept its integrity, being classified as preserved, none of the samples of this group presented attack of inflammatory cells to the epithelium. In the analysis of the connective tissue, four samples of this group were presented normal, without the inflammation presence, only one of the samples presented signals of inflammation, being classified as moderate one, all the samples presented its connective tissue organized, concerning the fibrosity degree, two samples had been classified as degree 3, two as degree 2 and a sample as degree 1, and a sample of this group possessed radicular cementum fragments wrapped by collagen fibers. In group II, four samples presented hyperplasia of the epithelium, being classified as degree 2, only one sample was free of hyperplasia, when the integrity of the epithelium was evaluated, three samples had been classified as preserved and two classified as disorganized, with the presence of inflammatory cells in the interior of the epithelium. Three samples of this group presented attack of inflammatory cells to the epithelium. In the analysis of the connective tissue, all the samples had been classified as organized, with four of the samples presenting signals of inflammation, with classified intensity as degree 3 in two samples and as degree 2 in others two samples, only one sample was classified free of inflammation. Russell\'s corpuscles have been found in three samples. Evaluating the fibrosity degree, three samples have been classified as degree 2 and two as degree 3, radicular cementum fragments were found in one sample of this group. In the statistics analysis statistical no significant differences were found for the variable hyperplasia, fibrosity and intensity of the inflammation when evaluated separately. When the interaction of the three variables was evaluated, also no statistical significant differences were found, having the two groups presented very close results. On the basis of the results obtained in this study, it was not possible to affirm that the present methodology allows to establish that an implantation system can provide better condition to the peri-implant soft tissue surroundings when compared with the other system.
216

Avaliação in vitro da infiltração de fluidos pela interface implante-pilar intermediário de três sistemas com conexão do tipo cone Morse e da capacidade de vedação de um material / In vitro evaluation of fluid penetration at the implant-abutment interface of three cone Morse systems and sealing ability of a material

Moraes, Flavia Maria Lopes de 27 September 2010 (has links)
A infiltração de fluido e bactérias nos espaços internos dos implantes foi observada em pilares intermediários parafusados, tanto em situações in vitro quanto in vivo devido à microfenda existente entre o implante e o pilar intermediário. Esse fato pode estar relacionado com a inflamação dos tecidos periimplantares e também com a produção de mau odor. O objetivo do presente estudo in vitro foi avaliar e comparar a ocorrência de infiltração de fluidos pela interface implante-pilar intermediário em três sistemas de implante com conexão do tipo cone Morse, e a capacidade de vedação de um adesivo anaeróbico, utilizando o radioisótopo Tecnécio-99m como marcador. Na primeira etapa, dez conjuntos implante-pilar intermediário de cada sistema foram imersos em solução contendo esse marcador, após a aplicação do torque recomendado pelo fabricante, e foram mantidos em pressão constante de 2 atm por um minuto. Na segunda etapa, um adesivo anaeróbico foi aplicado no pilar intermediário antes do mesmo ser parafusado ao seu respectivo implante. Após a aplicação da pressão, o infiltrado presente no interior dos implantes foi coletado com pontas de papel. Esse material foi depositado em tubos de ensaio para posterior leitura da radioatividade presente. A infiltração de fluido pela interface implante-pilar intermediário mostrou ser um fenômeno mensurável em todas as amostras dos três sistemas de implante com conexão do tipo cone Morse testados. A quantidade de infiltrado variou entre os sistemas e entre as amostras. A inconstância das amostras foi observada em todos os sistemas, no entanto, foi observado que o valor de infiltrado encontrado no Grupo 1 foi significantemente maior (p<0,05) do que o encontrado no Grupo 2, e não houve diferença estatística significante entre os Grupos 1 e 3, e entre os Grupos 2 e 3. Também foi observado que, com o uso do adesivo anaeróbico, os sistemas apresentaram diminuição da quantidade de infiltrado, sendo que a análise estatística dos valores obtidos com e sem o seu uso, mostraram significância a 1%. Além disso, com o uso do adesivo anaeróbico os três sistemas de implante testados passaram a ter comportamento semelhante, não tendo sido encontrada diferença estatística significante entre eles (p=0,5451). Considerando os limites deste estudo, pode-se concluir que os três sistemas de implante com conexão do tipo cone Morse testados permitiram a passagem de fluido do meio externo para o interior dos implantes, e que o material testado não foi capaz de impedir a penetração de fluido, apesar de ter reduzido significantemente a quantidade de infiltrado em todos os sistemas. / It has been observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria and fluids can penetrate the inner implant space as consequence of an existing microgap at the implant-abutment interface. This fact can be related to peri-implant tissue inflammation and malodor. The aim of the present study was to evaluate and compare the occurrence of fluid penetration throught implant-abutment interface in three cone Morse implant systems and sealing ability of an anaerobic adhesive using a radioisotope as trace. In the first phase, ten implant-abutment sets of each system were immersed in a solution with radioisotope, after manufacture recommended torque application. All assemblies were kept in a constant pressure of 2 atm for one minute. In the second phase, an anaerobic adhesive was applied before the abutments been torque-tightened to the same implant. After the pressure application, material inside implant bodies was colleted using a paper cone that was transferred to tubes for posterior verification of radioactivity. Fluid penetration at the implant-abutment interface was seen to be a recordable phenomenon in each assembly of the three cone Morse systems tested in this study. The quantity of infiltrated varied between systems and assemblies. The variable of the samples was observed in all systems, however, it was noted that the value of infiltrate found in Group 1 was significantly higher than that found in Group 2, and there was no statistical significant difference between the groups 1 and 3, and between groups 2 and 3. It was also noted that, using the adhesive anaerobic, the implant systems showed reduce infiltrate, and statistical analysis presented significance to 1%. Moreover, with the use of anaerobic adhesive, all three implant systems tested presented similar pattern, and no significant statistical difference was found (p=0,5451). Considering the limits of this study, the following conclusions can be drawn: the three cone Morse implant systems tested allowed the passage of fluid from external to the inside of the implants, and that the material tested was not capable of preventing the fluid penetration, despite having reduced significantly the amount of infiltrate in all systems.
217

Efeito da superfície hidrofílica na osseointegração de implantes em sítios com defeitos ósseos circunferenciais: estudo experimental em cães / Effects of hydrophilic surface on dental implants osseointegration in circumferential bone defects: an experimental study in dogs

Oliveira, Gustavo Augusto Grossi de 25 February 2013 (has links)
INTRODUÇÃO: A qualidade da interface osso-implante pode ser influenciada diretamente por aspectos inerentes ao tratamento da superfície do titânio e determina a forma que as células interagem, aderem e se fixam a ela, podendo potencializar e encurtar o tempo de osseointegração. Este estudo propôs-se a analisar alterações na osseointegração produzidas pela hidrofibilidade das superfícies dos implantes Neoss®. MATERIAIS E MÉTODOS: Foram utilizados 6 cães da raça labrador e instalados 44 implantes Neoss® bilateralmente na mandíbula com defeitos ósseos padronizados na região coronal: 22 implantes apresentavam superfície ProActive (hidrofílica) e outros 22 implantes eram de superfície Bimodal (hidrofóbica). Foram avaliados a resposta biológica nos períodos de uma semana e quatro semanas de osseointegração, utilizando parâmetros histológicos, histomorfométricos, fluorescência e de estabilidade mecânica aferido pelo método de análise de frequência de ressonância (RFA). As superfícies também foram submetidas à análise topográfica por interferometria óptica e quanto a propriedade de hidrofibilidade. RESULTADOS: Nos testes topográficos, a superfície ProActive apresentou valor de Sa de 0,4m contra Sa de 0,8m da superfície Bimodal, sugerindo menor rugosidade da superfície hidrofílica. A umectibillidade da superfície foi maior no grupo ProActive, exibindo valores de ângulos de contato de 27,2° contra 67,2° da superfície Bimodal. Ambas as superfícies apresentaram valores semelhantes nos períodos de uma e quatro semanas no que diz respeito à estabilidade mecânica do implante, aferidos com o RFA e nos parâmetros histomorfométricos em relação deposição óssea ao seu redor CONCLUSÕES: 1) A superfície ProActive apresentou valores menores de rugosidade e aumento da umectibilidade em relação aos implantes com superfície Bimodal. 2) A superfície ProActive utilizada no presente estudo não favoreceu os eventos de osseointegração nas condições períodos de 1 e 4 semanas avaliados. 3) Após 4 semanas de osseointegração, ocorreu aumento da estabilidade dos implantes instalados sem haver diferença entre as superfícies ProActive e Bimodal. 4) A estabilidade dos implantes, avaliados por meio do RFA, aumentou gradativamente durante a osseointegração, sem haver diferença entre as superfícies testadas. / INTRODUCTION: The quality of the bone-implant interface can be directly influenced by factors inherent to titanium surface treatment which determines cells interaction and adherence to shortening the time for osseointegration. This study aimed to assess changes on osseointegration produced by the hidrophibility of Neoss® implants surfaces. MATERIALS AND METHODS: Six labrador dogs were used and 44 Neoss® implants bilaterally installed in the mandible (ProActive with hydrophilic surface) and (Bimodal hydrophobic surface), in standardized bone defects in the coronal region. The biological responses in one and four weeks of osseointegration were evaluated using histological, histomorphometric, fluorescence analysis and mechanical stability measured by Resonance Frequency Analysis (RFA). The surfaces were also subjected to topographic analysis by optical interferometry and hydrophobicity by wettability analysis. RESULTS: The topographic surfaces test showed value of 0.4 micrometers for ProActive implants, against 0.8 micrometers for Bimodal implants, suggesting less hydrophilic surface roughness in the former (p0.05). The wettability values were higher in ProActive surface, with contact angles of 27.2° versus 67.2° of the Bimodal surface (p0.05). Both implant surfaces exhibited similar mechanical stability measured by RFA, as well as the histomorphometric parameters related to bone deposition onto the surfaces. CONCLUSIONS: 1) The ProActive surface showed lower roughness values and increased wettability compared to Bimodal surface. 2) The ProActive surface did not favor osseointegration at 1 and 4 weeks. 3) After 4 weeks of osseointegration the implants increased in stability, with no statistical differences between Bimodal and ProActive surfaces
218

Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexões /

Delben, Juliana Aparecida. January 2012 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Ricardo Faria Ribeiro / Banca: Nelson Renato França Alves da Silva / Banca: João Neudenir Arioli Filho / Resumo: Introdução: A performance de restaurações cerâmicas parafusadas a implantes com diferentes conexões diante de fadiga é um fator importante para o sucesso do tratamento. Proposição: O objetivo do estudo foi avaliar a confiabilidade e o modo de falha de coroas cerâmicas obtidas com pilares de zircônia parafusadas a implantes osseointegráveis de diferentes conexões. Material e método: Foram formados 3 grupos de acordo com as diferentes conexões pilar-implante: Grupo EH - hexágono externo, Grupo IH - hexágono interno e Grupo MT - Cone Morse. As coroas foram obtidas através da aplicação de cerâmica de revestimento sobre pilar de zircônia utilizando a técnica de aplicação em camadas e parafusadas aos implantes com parafusos de retenção específicos para cada sistema. Os espécimes foram submetidos ao teste de fadiga acelerado step-stress de acordo com os perfis leve (n=9), moderado (n=6) e agressivo (n=3) determinados após teste de resistência à fratura (n=4) em máquina de ensaio universal. Os dados foram inicialmente avaliados pela análise de use level probability Weibull. Os valores e intervalos de confiabilidade foram obtidos através de standard probability calculation. Considerando os valores de carga para a falha dos espécimes, foi calculada a distribuição de Weibull. Análise fractográfica foi conduzida através de estereomicroscopia e microscopia eletrônica de varredura. Resultado: O valor de β de todos os grupos (EH-β= 0,6307; IH-β=0,9730; MT-β=0,1942) sugere que as falhas foram mais associadas ao nível de carga do que ao dano acumulado. Os valores de confiabilidade para uma missão de 50.000 ciclos e carga de 400 N foram de 97% para o grupo EH, 46% para o grupo IH e 0,5% para o grupo MT com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The performance of screw-retained all-ceramic crowns attached to implants with different connections under fatigue is a relevant factor for treatment success. Purpose: The aim of this study was to evaluate the reliability and failure mode of screw-retained all-ceramic crowns fabricated with zirconia abutments attached to osseointegrated implants with different connections. Material and method: Three groups were designed according to the implant-abutment connection: Group EH - external hexagon, Group IH - internal hexagon and Group MT - Morse taper. Layering technique was used for veneering of zirconia abutments. The crowns were attached to the implants with the retention screws of each system. Step-stress accelerated fatigue test was conducted according to mild (n=9), moderate (n=6) and aggressive (n=3) profiles determined after single-load-to-fracture test (n=4) in a universal testing machine. Data was previously analyzed by use level probability Weibull. Standard probability calculation was used to determine the reliability and confidence bounds. Weibull distribution was calculated based on the load to failure. Failure modes were described under light polarized microscopy and scanning electron microscopy. Result: β of all groups (EH-β= 0.6307; IH-β=0.9730; MT-β=0.1942) suggested that failure was associated to load instead of cumulative damage. Significant difference was observed between the groups for the calculated reliability in a mission of 50,000 cycles at 400 N (97% for group EH, 46% for group IH... (Complete abstract click electronic access below) / Doutor
219

Avaliação comparativa da viabilidade celular imediata após osteotomia para implantes com fresas e piezocirurgia em tíbias de coelhos : análise imunoistoquímica /

Pereira, Cassiano Costa Silva. January 2010 (has links)
Resumo: O propósito desse trabalho foi avaliar o efeito da osteotomia para implantes sobre a viabilidade celular óssea imediata, comparando a utilização de fresas do sistema convencional com a piezocirurgia em tíbias de coelhos. Foram utilizados 6 coelhos machos, divididos em 2 etapas: (1) Fresas - 5 grupos (G1 a G5) correspondentes às osteotomias 10, 20, 30, 40 e 50 vezes, respectivamente. Cada leito ósseo recebeu a sequência de fresas: lança e helicoidais de 2,0 mm, 2,8 mm, 3,0 mm e 3,15 mm; (2) Piezocirurgia - 5 grupos (P1 a P5) correspondentes às osteotomias 10, 20, 30, 40 e 50 vezes, respectivamente, efetuadas pela sequência de pontas de 2,0 e 3,0 mm, mediante vibração ultrassônica piezoelétrica. As áreas osteotomizadas foram coletadas e processadas laboratorialmente. A análise imunoistoquímica demonstrou equilíbrio das expressões de OPG e RANKL, ou seja, formação e reabsorção óssea, tanto nas osteotomias com fresas, quanto na piezocirurgia, embora mais intensas nesta última. A expressão de OC apresentou-se bastante intensa nos grupos de piezocirurgia, mas com redução da imunomarcação a partir da 30ª osteotomia, enquanto manteve-se constante nos grupos fresados. A CAS3 evidenciou a viabilidade osteoblástica a partir da 20ª osteotomia com piezocirurgia e manteve-se constante até a 50ª. No grupo de fresas, notou-se aumento gradativo da expressão dessa proteína, conforme o aumento do número de osteotomias. De acordo com a metodologia aplicada, foi possível concluir que a piezocirurgia propicia maior viabilidade celular osteoblástica do que o sistema de fresas convencional / Abstract: The purpose of this study was to evaluate the effect of the osteotomy implant on bone cell viability immediately, comparing the use of conventional drilling system with piezosurgery® in tibiae of rabbits. We used 6 male rabbits were divided into 2 stages: (1) Drilling - 5 groups (G1 to G5) corresponding to the 10 osteotomies, 20, 30, 40 and 50 times respectively. Each received a bone bed following drills: Spear drill and 2.0 mm, 2.8 mm, 3.0 mm and 3.15 mm helicoidal drills, (2) Piezosurgery® - 5 groups (P1 to P5) corresponding to the 10 osteotomies, 20, 30, 40 and 50 times, respectively, analyzed by the sequence of inserts 2 and 3 mm by piezoelectric ultrasonic vibration. The receptor-beds were collected and processed in a laboratory. The immunohistochemical analysis showed balance expressions of OPG and RANKL, ie bone formation and resorption in both the osteotomies with drills and piezosurgery®, although more intense in the latter. The expression of OC had become quite intense in piezosurgery® groups, but with reduced immunostaining from the 30th osteotomy, while remained unchanged in groups drilled. The CAS3 showed the viability of the osteoblast from the 20th osteotomy with piezosurgery® and remained constant until the 50th. In the group of drills noticed a gradual increase in the expression of this protein, as the increase in the number of osteotomies. According to the methodology, it was concluded that the piezosurgery® provides greater osteoblastic cell viability than the system of conventional drilling / Orientador: Roberta Okamoto / Coorientador: Cristina Antoniali Silva / Banca: Idelmo Rangel Garcia Júnior / Banca: Darceny Zanetta Barbosa / Mestre
220

Avaliação do reparo ósseo na interface osso/implante em ratas com deficiência de estrógeno tratadas com OPG-Fc humano ou ranelato de estrôncio : análise histométrica, imunoistoquímica, biomecânica, por microtomografia computadorizada e microscopia confocal /

Coléte, Juliana Zorzi. January 2018 (has links)
Orientador: Roberta Okamoto / Coorientador: Idelmo Rangel Garcia Júnior / Banca: Francisley Ávila Souza / Banca: Leonardo Perez Faverani / Banca: Elisa Mattias Sartori / Banca: Gabriel Ramalho Ferreira / Resumo: Avaliar o reparo ósseo periimplantar em ratas submetidas à ovariectomia e tratadas com Ranelato de Estrôncio (625mg/kg/dia) ou OPG-Fc (10mg/Kg/2 vezes por semana). Material e Método: Sessenta e quatro ratas, com peso aproximado de 300 gramas, divididas em 4 grupos experimentais conforme tratamento medicamentoso e análises: SHAM; OVX; OVX/RE; OVX/OPG-Fc. Cada animal recebeu 2 implantes sendo 1 em cada metáfise tibial. A eutanásia foi realizada aos 42 e 60 dias após a instalação dos implantes. Foram realizadas as análises de microtomografia computadorizada (micro CT), biomecânica (torque reverso) histométrica, por microscopia confocal a laser, análise da expressão gênica por PCR em tempo real, histológica e imunoistoquímica. Os resultados histológicos evidenciaram para o grupo OVX-RE aspecto de neoformação óssea melhorada, com trabéculas mais espessas e baixa presença de tecido conjuntivo, comparado ao grupo OVX. Os resultados imunoistoquímicos demonstraram intensa marcação de OPG para o grupo OVX-RE e intensa marcação de RANKL para o grupo OVX. Já a análise por microscopia confocal evidenciou que o grupo OVX-RE obteve marcação superior para vermelho de alizarina comparado aos outros dois grupos (Tukey test - P < 0,05). Para os parâmetros BV/TV, Tb.Th, o grupo OVX/RE apresentou os maiores valores em relação aos demais grupos. Para Tb.Sp o grupo OVX/OPG-Fc apresentou o melhor resultado (OVX: p<0,05 e OVX/RE: p>0,05), e Tb.N, houve diferença estatisticamente significante na compa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: O bjectives: E valuate the peri - implant bone repair in rats submitted to ovariectomy and treated with Strontium Ranelate (625mg/kg/day) or OPG - Fc (10mg/kg/2 times per week). Material and Method: six ty - four rats weighing about 300 grams, they were divided into 4 experimental groups according with the treatment and analysis: SHAM; OVX; OVX/RE; OVX/OPG - Fc. Each animal received 2 implants, 1 in each tibial metaphysis. Euthanasia was performed 42 and 60 days after implant installation. Computed micro - tomography (mi cro - CT), biomechanical (reverse torque), histometrical, laser confocal microscopy, real - time gene expression ( RT - PCR), histology and immunohistochemiscal analysis. The histological results revealed for the OVX - RE group a better bone neoformation with thick er trabeculae and low connective tissue compared to OVX group. The immunohistochemical results showed intense labeling of OPG to the OVX - RE group and intense labeling of RANKL to the OVX group. Confocal microscopy analysis exhibited that the OVX - RE group o btained a greater red alizarin marking compared to the others two groups (Tukey test - p<0.05). For the parameters BV/TV, Tb.Th, the OVX/RE group showed the larger values in relation to the other groups. For Tb.Sp the OVX/OPG - Fc group presented the best re sult (OVX: p<0.05 and OVX/RE: p> 0.05), and the Tb.N exhibited a statistical significant difference in the combination of results between the OVX and OVX / OPG - Fc groups (p<0.05). For t... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0772 seconds