• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 1
  • 1
  • Tagged with
  • 30
  • 9
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo de transistores de tunelamento controlados por efeito de campo. / Study of tunnel field effect transistors.

Martino, Márcio Dalla Valle 26 March 2012 (has links)
Este trabalho apresenta o estudo de transistores de tunelamento controlados por efeito de campo, denominados TFETs. Foram realizadas análises com base em explicação teórica, simulação numérica e medidas experimentais para demonstrar a viabilidade do uso desta tecnologia como alternativa para permitir o contínuo escalamento de dispositivos. A motivação para o uso de transistores com corrente principal resultante do tunelamento de banda para banda consiste na proposta de superar o limite físico de inclinação de sublimiar da tecnologia CMOS convencional de 60 mV/década sob temperatura ambiente. Afinal, esta limitação impede a redução na tensão de alimentação de circuitos e, consequentemente, apresenta crescentes problemas quanto à dissipação de potência. Com este objetivo, foram realizadas simulações numéricas de diversas geometrias alternativas visando atenuar as características indesejáveis dos TFETs, como a corrente ambipolar e a relativamente baixa relação ION/IOFF. Inicialmente são definidos os modelos necessários para representar adequadamente os fenômenos relevantes sob variação de temperatura e é definida uma estrutura capaz de minimizar os efeitos da ambipolaridade. Posteriormente, medidas experimentais foram utilizadas para calibrar as simulações e estudar o efeito da temperatura e do dimensionamento no funcionamento de dispositivos desta tecnologia. Comparando resultados práticos e simulados, nota-se como uma redução no comprimento de porta, com a consequente inserção de uma subposição (underlap) em relação à junção canal/dreno, e uma diminuição na temperatura permitem a obtenção de valores promissores de inclinação de sublimiar e de relação ION/IOFF, compatível com a proposta de futuras aplicações digitais e analógicas. / This works presents the study of tunneling field effect transistors, namely TFETs. Analyses were performed based on theoretical explanations, numerical simulations and experimental data in order to show this technology suitability as an alternative for the continuous devices scaling. The basic idea of making use of band-to-band tunneling as the main current component comes from the possibility of reaching sub-60 mV/decade subthreshold slopes at room temperature, differently from conventional CMOS devices. After all, this physical limitation causes relevant power dissipation issues, since it requires relatively high power supply voltages. Bearing this objective, numerical simulations of several alternative geometries were performed in order to tackle TFETs disadvantages, as the undesirable ambipolar currents and the low ION/IOFF ratio. At first, it was necessary to choose the most appropriate models to take into consideration the relevant phenomena under temperature variation and to define the physical structure in order to minimize ambipolar effects. After these analyses, experimental data were used to calibrate simulation parameters and to study how temperature and physical dimensions affect the performance of devices based on this technology. Comparing experimental and simulated results, it was possible to notice that when the structure is designed with gate underlap related to channel/drain junction and the temperature decreases, the obtained values for subthreshold slope and ION/IOFF ratio may be used as an important reference of this technology as a promising alternative for both digital and analog applications.
22

Estudo de transistores de tunelamento controlados por efeito de campo. / Study of tunnel field effect transistors.

Márcio Dalla Valle Martino 26 March 2012 (has links)
Este trabalho apresenta o estudo de transistores de tunelamento controlados por efeito de campo, denominados TFETs. Foram realizadas análises com base em explicação teórica, simulação numérica e medidas experimentais para demonstrar a viabilidade do uso desta tecnologia como alternativa para permitir o contínuo escalamento de dispositivos. A motivação para o uso de transistores com corrente principal resultante do tunelamento de banda para banda consiste na proposta de superar o limite físico de inclinação de sublimiar da tecnologia CMOS convencional de 60 mV/década sob temperatura ambiente. Afinal, esta limitação impede a redução na tensão de alimentação de circuitos e, consequentemente, apresenta crescentes problemas quanto à dissipação de potência. Com este objetivo, foram realizadas simulações numéricas de diversas geometrias alternativas visando atenuar as características indesejáveis dos TFETs, como a corrente ambipolar e a relativamente baixa relação ION/IOFF. Inicialmente são definidos os modelos necessários para representar adequadamente os fenômenos relevantes sob variação de temperatura e é definida uma estrutura capaz de minimizar os efeitos da ambipolaridade. Posteriormente, medidas experimentais foram utilizadas para calibrar as simulações e estudar o efeito da temperatura e do dimensionamento no funcionamento de dispositivos desta tecnologia. Comparando resultados práticos e simulados, nota-se como uma redução no comprimento de porta, com a consequente inserção de uma subposição (underlap) em relação à junção canal/dreno, e uma diminuição na temperatura permitem a obtenção de valores promissores de inclinação de sublimiar e de relação ION/IOFF, compatível com a proposta de futuras aplicações digitais e analógicas. / This works presents the study of tunneling field effect transistors, namely TFETs. Analyses were performed based on theoretical explanations, numerical simulations and experimental data in order to show this technology suitability as an alternative for the continuous devices scaling. The basic idea of making use of band-to-band tunneling as the main current component comes from the possibility of reaching sub-60 mV/decade subthreshold slopes at room temperature, differently from conventional CMOS devices. After all, this physical limitation causes relevant power dissipation issues, since it requires relatively high power supply voltages. Bearing this objective, numerical simulations of several alternative geometries were performed in order to tackle TFETs disadvantages, as the undesirable ambipolar currents and the low ION/IOFF ratio. At first, it was necessary to choose the most appropriate models to take into consideration the relevant phenomena under temperature variation and to define the physical structure in order to minimize ambipolar effects. After these analyses, experimental data were used to calibrate simulation parameters and to study how temperature and physical dimensions affect the performance of devices based on this technology. Comparing experimental and simulated results, it was possible to notice that when the structure is designed with gate underlap related to channel/drain junction and the temperature decreases, the obtained values for subthreshold slope and ION/IOFF ratio may be used as an important reference of this technology as a promising alternative for both digital and analog applications.
23

Eficiência cardiorrespiratória durante o exercício progressivo em pacientes com síndrome metabólica e apneia obstrutiva do sono / Cardiorespiratory efficiency during progressive exercise in patients with metabolic syndrome and obstructive sleep apnea

Carvalho, Jefferson Cabral de 19 May 2017 (has links)
Introdução. A baixa capacidade aeróbia é um importante marcador de mau prognóstico e um forte preditor de risco de morte em pacientes encaminhados para o teste de esforço cardiopulmonar (TECP) por razões clínicas. O índice oxygen uptake efficiency slope (OUES), um novo índice de eficiência cardiorrespiratória, tem sido utilizado como marcador submáximo durante o TECP. Estudos recentes sugerem que a leptina pode desempenhar um papel importante na regulação da respiração e, consequentemente, o aumento dos níveis de leptina pode estar relacionado com a diminuição do OUES. No entanto, o impacto da síndrome metabólica (SMet) e da apneia obstrutiva do sono (AOS) no OUES é desconhecido. Objetivo. Investigar o comportamento do OUES em pacientes com SMet, associado ou não à AOS. Métodos. Foram estudados 73 pacientes com SMet (ATP-III), alocados em dois grupos de acordo com o índice de apneia/hipopneia (IAH) obtido na polissonografia noturna: SMet+AOS (IAH >= 15 eventos/hora, n=38, 49±1 anos, 33±0,6 kg/m2) e SMet-AOS (IAH < 15 eventos/hora, n=35, 46±1 anos, 31,8±0,6 kg/m2). Um grupo controle saudável (CS, n=20, 47±1 anos, 26,1±0,8 kg/m2), pareado por idade e gênero, foi também estudado. Os pacientes realizaram as seguintes avaliações: polissonografia; exames laboratoriais (glicemia, triglicérides, colesterol total e frações, leptina e proteína C-reativa); medidas antropométricas (altura, peso corporal, índice de massa corpórea, circunferência abdominal); composição corporal pela bioimpedância; medidas de pressão arterial; e TECP. Resultados. Ambos os grupos com SMet apresentaram prejuízo quando comparados ao grupo CS no peso, índice de massa corpórea e nos fatores de risco da SMet (circunferência abdominal, glicemia, triglicérides, HDL-c e pressão arterial sistólica e diastólica, P < 0,05). No TECP os grupos SMet+AOS e SMet-AOS apresentaram menores valores de consumo de oxigênio pico (VO2pico, 22,2±0,7; 21,7±0,9 e 28,0±1,1 ml/kg/min, respectivamente, Interação; P < 0,001) comparados com CS. Da mesma forma, os grupos SMet tiveram menores: VO2 no limiar anaeróbio (VO2LA), na relação VO2 e carga de trabalho (deltaVO2/deltaW) e no OUES (25,3±0,8; 25,0±0,9 e 31,1±1,2; Interação; P < 0.001) quando comparado com CS. Em análises posteriores, o OUES se correlacionou apenas com a massa gorda e com a leptina (R=-0,35; P=0,006). Conclusão. Independente da presença da AOS, pacientes com SMet apresentam diminuição da eficiência cardiorrespiratória. Os níveis elevados de leptina pode ser uma das explicações para essa diminuição nesses pacientes / Introduction. Low aerobic capacity is an important marker of poor prognosis and a strong predictor of risk of death in patients referred for cardiopulmonary exercise testing (CPET) for clinical reasons. The oxygen uptake efficiency slopes (OUES), a new cardiorespiratory efficiency index, has been used as a submaximal marker during CPET. Recent studies suggest that leptin may play an important role in regulating respiration, and consequently, increased levels of leptin may be related to decreased OUES. However, the impact of metabolic syndrome (MetS) and obstructive sleep apnea (OSA) in the OUES is unknown. Objective. To investigate the OUES in MetS patients with or without OSA. Methods. We studied 73 patients with MetS (ATP-III), allocated into two groups according to apnea/hypopnea index (AHI), assessed by nocturnal polysomnography: MetS+OSA (AHI >= 15 events/hour, n=38, 49±1 years, 33±0.6 kg/m2) and MetS-OSA (AHI < 15 events/hour, n=35, 46±1 years, 32±0.6 kg/m2). A healthy control group (CG, n=20, 47±1 years, 26.1±0.8 kg/m2), matched for age and gender, was also studied. The patients performed the following evaluations: polysomnography; Laboratory tests (glycemia, triglycerides, total cholesterol and fractions, leptin and C-reactive protein); Anthropometric measurements (height, body weight, body mass index, waist circumference); Body composition by bioimpedance; Blood pressure measurements; and CPET. Results. Both MetS groups had impairment in weight, body mass index, and MetS risk factors (waist circumference, glycemia, triglycerides, HDL-c and systolic and diastolic blood pressure, P < 0.05) compared with CG. MetS+OSA and MetS-OSA groups presented lower values of peak oxygen consumption (VO2peak, 22.2±0.7, 21.7±0.9 and 28.0±1.1 ml/kg/min, respectively; Interaction; P < 0.001) compared to CG. In the same way, MetS groups had lowest: VO2 at anaerobic threshold (VO2LA), ratio of VO2 and workload (deltaVO2/deltaW) and OUES (25.3±0.8, 25.0±0.9 and 31.1±1.2, Interaction; P < 0.001) compared with CG. In further analyzes, OUES correlated only with fat mass and leptin (R =-0.35, P =0.006). Conclusion. Regardless of the presence of OSA, MetS patients present decreased cardiorespiratory efficiency. Elevated levels of leptin may be one of the explanations for this decrease in these patients
24

Avaliação da angulação e inclinação coronárias com modelos digitais em pacientes tratados ortodonticamente / Evaluation of crown inclination and angulation using 3-dimensional digital models of orthodontics treated patients

Castro, Iury Oliveira 13 May 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-08-09T14:20:25Z No. of bitstreams: 2 Tese - Iury Oliveira Castro - 2016.pdf: 1542030 bytes, checksum: ee20c049579ce883ac06b1bb4d553189 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-09T14:26:52Z (GMT) No. of bitstreams: 2 Tese - Iury Oliveira Castro - 2016.pdf: 1542030 bytes, checksum: ee20c049579ce883ac06b1bb4d553189 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-09T14:26:53Z (GMT). No. of bitstreams: 2 Tese - Iury Oliveira Castro - 2016.pdf: 1542030 bytes, checksum: ee20c049579ce883ac06b1bb4d553189 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-05-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Introduction: The incorporation of new alternatives and methods apply to the orthodontics for the analysis of crown angulation and inclination is a challenge. The contribution of tools that enable three-dimensional analysis has been gradually incorporated into dental research. Objective: This study evaluated the crown inclination and angulation of patients in orthodontic treatment using digital models and cone beam computed tomography. Methodology: With the three-dimensional cephalometric software was created cephalometric analysis to evaluate the crown angulation and inclination in digital models of 26 patients, except second and third molars. For the results of crown angulation and inclination based on Camper and Frankfurt plans were required cone beam computed tomography images. Student's t- test was used to compare the intra and inter-group averages and Pearson's correlation coefficient used to evaluate the results between the groups Camper, Frankfurt and occlusal. Results: The analysis of the reproducibility of the method did not reveal a statistically significant difference. In assessing intra-group before and after orthodontic treatment the lower lateral incisors, the lower right first molar, the canine, and the first and second premolars presented statistically significant differences in crown inclinations. The upper right first molar and the lower left molar, the lower second premolar, the lower right first premolar, and the lower lateral incisors presented statistically significant differences in angulation. In the intergroup evaluation, post treatment and prescriptions, all of the results of the crown inclination and angulation presented statistically significant differences except the crown angulation of the second superior premolars and the first inferior molars. The study shows that between the Camper-occlusal, the Camper-Frankfurt and the Frankfurt-occlusal planes, the measures of the crown inclination for incisors and canine teeth did not present a correlation and other correlations were weak or inverse. The results of the crown angulation presented a strong correlation, except for central inferior incisors and upper lateral incisors, which demonstrated a moderate correlation to the Camper-occlusal and Frankfurt-occlusal planes. Conclusion: The crown angulation and inclination can be determined by means of digital models and it is evident that there is a need for additional bend to obtain crown angulation and inclination with values close to those recommended in preset brackets. The measures of the crown angulation and inclination presented correlations when evaluated by the Camper, Frankfurt and occlusal planes with the exception of the crown inclination of the incisors and canine teeth. / Introdução: A incorporação de novas alternativas e métodos aplicáveis à ortodontia para a análise da angulação e inclinação coronária constitui um verdadeiro desafio. A contribuição de ferramentas que permitem análises tridimensionais tem sido gradativamente incorporada à pesquisa odontológica. Objetivo: O presente estudo avaliou a inclinação e a angulação coronária em pacientes tratados ortodonticamente usando modelos digitais e tomografia computadorizada de feixe cônico. Metodologia: Com o módulo de cefalometria tridimensional do Software VistaDent 3D foi criado análise cefalométrica para avaliar a inclinação e angulação coronária em modelos digitais de 26 pacientes, exceto segundos e terceiros molares. Para obter os resultados de angulação e inclinação coronária com base nos planos de Camper e Frankfurt, foram necessárias documentações de pacientes com imagens tomográficas finais. Foi utilizado o teste t-Student para comparar as médias intra e intergrupo e o coeficiente de correlação de Pearson para avaliar os resultados entre os grupos Camper, Frankfurt e oclusal. Resultados: A análise da reprodutibilidade do método não revelou diferença estatisticamente significante. Quanto à avaliação intragrupo, antes e depois do tratamento ortodôntico, os incisivos laterais inferiores, primeiro molar inferior direito, os caninos, primeiros e segundos pré-molares apresentaram diferenças estatisticamente significantes para inclinações. Primeiro molar superior direito e inferior esquerdo, segundos pré-molares inferiores, primeiro premolar inferior direito e incisivos laterais inferiores apresentaram diferenças estatisticamente significantes para angulações. Quanto à avaliação intergrupo, depois do tratamento ortodontico e prescrições, todos os resultados de inclinação e angulação apresentaram diferenças estatisticamente significantes, exceto a angulação dos segundos pré-molares superiores e primeiros molares inferiores. O estudo aponta que entre os planos Camper-oclusal, Camper-Frankfurt e Frankfurt-oclusal as medidas de inclinação coronária para incisivos e caninos não apresentaram correlação, outros correlação fraca ou inversa. Os resultados da angulação coronária apresentaram forte correlação, exceto incisivos centrais inferiores e laterais superiores que demonstraram moderada correlação para Camper-oclusal e Frankfurt-oclusal. Conclusão: A angulação e inclinação coronária podem ser mensuradas por meio de modelos digitais e os resultados sugerem a necessidade de dobras adicionais no fio ortodôntico para obtenção de angulação e inclinação coronária com valores próximos aos preconizados em braquetes pré-ajustados. As medidas de angulação e inclinação coronárias apresentaram correlacionadas quando avaliadas pelos planos de Camper, Frankfurt e oclusal, exceto a inclinação dos incisivos e caninos.
25

Análise dos efeitos razão de aspecto e inclinação na convecção natural em cavidades via transformação integral / Analysis of aspect radio and inclination effects in the natural convection in cavities through integral transformation

Silva, Marcos de Souza e 11 March 2002 (has links)
In this work, the effects of the aspect radio and inclination angle in the convection heat transfer inside a square cavity are analyzed through integral transformation. The numerical simulations were made in square and plane cavity in a fluid with constant and variable properties and identifying the effect of the temperature variations. Varying the geometry of the cavity and its inclination it was identified the most sensitive properties at the temperature variations, as well as the geometric combinations which optimize the convection heat transfer. The Generalized Integral Transform Technique (JLWW) was capable to simulate the physical phenomenon successfully, capturing recirculations in critical convective cases numerically. The correlations were established between the rate of convection heat transfer and the aspect radio and the inclination angle of the cavity. / Neste trabalho, serão analisados os efeitos da razão de aspecto e ângulo de inclinação na transferência de calor por convecção via transformação integral, através de simulações em uma cavidade quadrada e plana com um fluido de propriedades constantes e variáveis, identificando a influência à variações de temperatura, bem como as combinações geométricas que otimizam a troca de calor por convecção. A Técnica da Transformada Integral Generalizada (Generalized Integral Transform Technique - JLWW) foi capaz de obter sucesso na simulação do fenômeno físico, sendo capaz de capturar recirculações em casos convectivos críticos do ponto de vista numérico. Foram estabelecidas correlações entre a taxa de transferência de calor por convecção e a razão de aspecto e o ângulo de inclinação da cavidade. / Mestre em Engenharia Mecânica
26

Estratégias de imunização de carteira de renda fixa no Brasil

Meirelles, Sofia Kusiak de Sousa 23 January 2015 (has links)
Submitted by Sofia Meirelles (sofiaksm@gmail.com) on 2015-02-11T16:47:40Z No. of bitstreams: 1 Estratégias de imunização de carteiras de renda fixa no Brasil - Sofia Meirelles.pdf: 1823249 bytes, checksum: c9dbdd216cfecbe8d0f18ca7f411d3cd (MD5) / Approved for entry into archive by Renata de Souza Nascimento (renata.souza@fgv.br) on 2015-02-11T17:06:46Z (GMT) No. of bitstreams: 1 Estratégias de imunização de carteiras de renda fixa no Brasil - Sofia Meirelles.pdf: 1823249 bytes, checksum: c9dbdd216cfecbe8d0f18ca7f411d3cd (MD5) / Made available in DSpace on 2015-02-11T17:07:50Z (GMT). No. of bitstreams: 1 Estratégias de imunização de carteiras de renda fixa no Brasil - Sofia Meirelles.pdf: 1823249 bytes, checksum: c9dbdd216cfecbe8d0f18ca7f411d3cd (MD5) Previous issue date: 2015-01-23 / This paper aims to statistically compare the performance of two hedging strategies for Brazilian fixed income portfolios, with discrete rebalancing. The first hedging strategy matches duration, and hence it considers only small parallel changes in the yield curve. The alternative methodology ponders level, curvature and convexity shifts through a factor model. We first estimate the yield curve using the polynomial model of Nelson & Siegel (1987) and Diebold & Li (2006) and then immunize the fixed income portfolio using Litterman & Scheinkman’s (1991) hedging procedure. The alternative strategy for portfolio immunization outperforms duration matching in the empirical exercise we contemplate. Additionally, we show that rebalancing the hedging portfolio every month is more efficient than at other frequencies. / Este trabalho visa comparar, estatisticamente, o desempenho de duas estratégias de imunização de carteiras de renda fixa, que são recalibradas periodicamente. A primeira estratégia, duração, considera alterações no nível da estrutura a termo da taxa de juros brasileira, enquanto a abordagem alternativa tem como objetivo imunizar o portfólio contra oscilações em nível, inclinação e curvatura. Primeiro, estimamos a curva de juros a partir do modelo polinomial de Nelson & Siegel (1987) e Diebold & Li (2006). Segundo, imunizamos a carteira de renda fixa adotando o conceito de construção de hedge de Litterman & Scheinkman (1991), porém assumindo que as taxas de juros não são observadas. O portfólio imunizado pela estratégia alternativa apresenta empiricamente um desempenho estatisticamente superior ao procedimento de duração. Mostramos também que a frequência ótima de recalibragem é mensal na análise empírica.
27

O perfil motivacional e a inclinação de carreira do estudante e o profissional da tecnologia da informação

Müller, Evelyn Souto Martins January 2009 (has links)
Submitted by Estagiário SPT BMHS (spt@fgv.br) on 2011-11-11T10:52:29Z No. of bitstreams: 1 1418712.pdf: 6401637 bytes, checksum: a39ee8c59a4e30fd930e020b755a3e4c (MD5) / Approved for entry into archive by Estagiário SPT BMHS (spt@fgv.br) on 2011-11-11T10:52:45Z (GMT) No. of bitstreams: 1 1418712.pdf: 6401637 bytes, checksum: a39ee8c59a4e30fd930e020b755a3e4c (MD5) / Approved for entry into archive by Estagiário SPT BMHS (spt@fgv.br) on 2011-11-11T10:52:59Z (GMT) No. of bitstreams: 1 1418712.pdf: 6401637 bytes, checksum: a39ee8c59a4e30fd930e020b755a3e4c (MD5) / Made available in DSpace on 2011-11-11T10:53:09Z (GMT). No. of bitstreams: 1 1418712.pdf: 6401637 bytes, checksum: a39ee8c59a4e30fd930e020b755a3e4c (MD5) Previous issue date: 2009 / A área de tecnologia de informação (TI) tem sofrido mudanças constantes que, por consequência, impactam diretamente no profissional e nas empresas que trabalham com este setor. O presente estudo visou identificar a questão motivacional na relação do profissional de TI com seu trabalho, assim como a inclinação de carreira destes profissionais. Para tal, primeiramente foi realizado um estudo teórico sobre o tema, de forma a constituir os alicerces para a pesquisa. Uma vez tendo-se a questão a ser investigada bem definida, foi realizada a pesquisa dentro de um grupo de profissionais de TI e de outro grupo de estudantes de TI como alvo da pesquisa. Foram aplicados questionários fechados com o grupo focal que foi dividido em profissionais e estudantes de TI. Os dois instrumentos utilizados foram o inventário de Valores de Schwartz (IVS) que oferecem algumas perspectivas de valorização do empregado, que correspondem as suas metas e interesses, e o outro instrumento foi o questionário de Edgar Schein sobre inclinação profissional, que permite identificar a relação e as perspectivas destes com o trabalho e suas vidas. Com os resultados expostos constatou-se, através do Inventário de Valores de Schwartz e do questionário de Inclinação Profissional de Schein, que os estudantes e profissionais de TI aqui pesquisados são indivíduos auto-determinados, que valorizam o estilo de vida, são benevolentes e hedonistas, buscam o bem-estar e a satisfação no trabalho e adoram desafios. / The field of infonnation technology (IT) has been subjected to various developments and modifications, which consequently have a direct impact on professionals and companies involved in IT. The present study is aimed to identify the motivational question conceming the relationship between the professional in IT and his/her work, as well as to estimate the preference of their career (career anchors). Therefore, some theories about the topic were initially considered, in order to develop a justification for the study. When the question to be investigated had been well defined, an investigation was done within a group of IT professionals, and with IT students as a comparative control group. Both groups received closed questionnaires. These instruments consisted of the inventory of the Schwartz Values (lSV) that offer some perspectives about the valorization of the employed subject and that correspond to his/her aims and interests; the other instrument was the questionnaire developed by Edgar Schein about the professional preference allowing to identify the relationship and their perspectives with work and individual life. The results of both questionnaires showed that the IT students and professionals are self-detennined individuaIs giving much value to life style, and that they are benevolent and hedonic. They harvest well-being and satisfaction from their work and like to be challenged.
28

Eficiência cardiorrespiratória durante o exercício progressivo em pacientes com síndrome metabólica e apneia obstrutiva do sono / Cardiorespiratory efficiency during progressive exercise in patients with metabolic syndrome and obstructive sleep apnea

Jefferson Cabral de Carvalho 19 May 2017 (has links)
Introdução. A baixa capacidade aeróbia é um importante marcador de mau prognóstico e um forte preditor de risco de morte em pacientes encaminhados para o teste de esforço cardiopulmonar (TECP) por razões clínicas. O índice oxygen uptake efficiency slope (OUES), um novo índice de eficiência cardiorrespiratória, tem sido utilizado como marcador submáximo durante o TECP. Estudos recentes sugerem que a leptina pode desempenhar um papel importante na regulação da respiração e, consequentemente, o aumento dos níveis de leptina pode estar relacionado com a diminuição do OUES. No entanto, o impacto da síndrome metabólica (SMet) e da apneia obstrutiva do sono (AOS) no OUES é desconhecido. Objetivo. Investigar o comportamento do OUES em pacientes com SMet, associado ou não à AOS. Métodos. Foram estudados 73 pacientes com SMet (ATP-III), alocados em dois grupos de acordo com o índice de apneia/hipopneia (IAH) obtido na polissonografia noturna: SMet+AOS (IAH >= 15 eventos/hora, n=38, 49±1 anos, 33±0,6 kg/m2) e SMet-AOS (IAH < 15 eventos/hora, n=35, 46±1 anos, 31,8±0,6 kg/m2). Um grupo controle saudável (CS, n=20, 47±1 anos, 26,1±0,8 kg/m2), pareado por idade e gênero, foi também estudado. Os pacientes realizaram as seguintes avaliações: polissonografia; exames laboratoriais (glicemia, triglicérides, colesterol total e frações, leptina e proteína C-reativa); medidas antropométricas (altura, peso corporal, índice de massa corpórea, circunferência abdominal); composição corporal pela bioimpedância; medidas de pressão arterial; e TECP. Resultados. Ambos os grupos com SMet apresentaram prejuízo quando comparados ao grupo CS no peso, índice de massa corpórea e nos fatores de risco da SMet (circunferência abdominal, glicemia, triglicérides, HDL-c e pressão arterial sistólica e diastólica, P < 0,05). No TECP os grupos SMet+AOS e SMet-AOS apresentaram menores valores de consumo de oxigênio pico (VO2pico, 22,2±0,7; 21,7±0,9 e 28,0±1,1 ml/kg/min, respectivamente, Interação; P < 0,001) comparados com CS. Da mesma forma, os grupos SMet tiveram menores: VO2 no limiar anaeróbio (VO2LA), na relação VO2 e carga de trabalho (deltaVO2/deltaW) e no OUES (25,3±0,8; 25,0±0,9 e 31,1±1,2; Interação; P < 0.001) quando comparado com CS. Em análises posteriores, o OUES se correlacionou apenas com a massa gorda e com a leptina (R=-0,35; P=0,006). Conclusão. Independente da presença da AOS, pacientes com SMet apresentam diminuição da eficiência cardiorrespiratória. Os níveis elevados de leptina pode ser uma das explicações para essa diminuição nesses pacientes / Introduction. Low aerobic capacity is an important marker of poor prognosis and a strong predictor of risk of death in patients referred for cardiopulmonary exercise testing (CPET) for clinical reasons. The oxygen uptake efficiency slopes (OUES), a new cardiorespiratory efficiency index, has been used as a submaximal marker during CPET. Recent studies suggest that leptin may play an important role in regulating respiration, and consequently, increased levels of leptin may be related to decreased OUES. However, the impact of metabolic syndrome (MetS) and obstructive sleep apnea (OSA) in the OUES is unknown. Objective. To investigate the OUES in MetS patients with or without OSA. Methods. We studied 73 patients with MetS (ATP-III), allocated into two groups according to apnea/hypopnea index (AHI), assessed by nocturnal polysomnography: MetS+OSA (AHI >= 15 events/hour, n=38, 49±1 years, 33±0.6 kg/m2) and MetS-OSA (AHI < 15 events/hour, n=35, 46±1 years, 32±0.6 kg/m2). A healthy control group (CG, n=20, 47±1 years, 26.1±0.8 kg/m2), matched for age and gender, was also studied. The patients performed the following evaluations: polysomnography; Laboratory tests (glycemia, triglycerides, total cholesterol and fractions, leptin and C-reactive protein); Anthropometric measurements (height, body weight, body mass index, waist circumference); Body composition by bioimpedance; Blood pressure measurements; and CPET. Results. Both MetS groups had impairment in weight, body mass index, and MetS risk factors (waist circumference, glycemia, triglycerides, HDL-c and systolic and diastolic blood pressure, P < 0.05) compared with CG. MetS+OSA and MetS-OSA groups presented lower values of peak oxygen consumption (VO2peak, 22.2±0.7, 21.7±0.9 and 28.0±1.1 ml/kg/min, respectively; Interaction; P < 0.001) compared to CG. In the same way, MetS groups had lowest: VO2 at anaerobic threshold (VO2LA), ratio of VO2 and workload (deltaVO2/deltaW) and OUES (25.3±0.8, 25.0±0.9 and 31.1±1.2, Interaction; P < 0.001) compared with CG. In further analyzes, OUES correlated only with fat mass and leptin (R =-0.35, P =0.006). Conclusion. Regardless of the presence of OSA, MetS patients present decreased cardiorespiratory efficiency. Elevated levels of leptin may be one of the explanations for this decrease in these patients
29

Comparação dos Métodos de Paralelismo de Conversores para o Compartilhamento de Potência em Microrredes

OLIVEIRA, Érika Matos de 29 July 2016 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2017-01-27T17:17:31Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Erika_1.pdf: 4090096 bytes, checksum: aad3d3481e2a810cc8765c9bade0883b (MD5) / Made available in DSpace on 2017-01-27T17:17:31Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Erika_1.pdf: 4090096 bytes, checksum: aad3d3481e2a810cc8765c9bade0883b (MD5) Previous issue date: 2016-07-29 / FACEPE / Microrrede é um conjunto de geração distribuída e sistemas de armazenamento de energia que abastece a demanda de um grupo de consumidores. A existência de um controle local independente da rede elétrica define uma microrrede, a qual pode se conectar ao sistema tradicional de potência ou desconectar-se e funcionar de forma autônoma a depender das condições físicas e/ou econômicas. O presente trabalho apresenta dois métodos de controle para o paralelismo de inversores em microrredes, o controle por inclinação e o controle mestre-escravo, com o objetivo de realizar um estudo comparativo. Primeiramente, são mostrados os conceitos de geração distribuída, microrredes e paralelismo de inversores. Depois, são apresentados os fundamentos teóricos e as principais características dos controles por inclinação e mestre-escravo. Por fim, é feita uma comparação entre as duas técnicas de controle para que permita definir qual é a melhor. Esta comparação é feita por meio de simulações de uma microrrede, analisando o seu desempenho nas situações conectada à rede elétrica principal, em ilhamento e durante o transitório de desconexão. Também é observado o comportamento de grandezas como corrente, amplitude e frequência da tensão e ainda o compartilhamento de carga entre os inversores. / Microgrid is a set of distributed generation and energy storage systems that supplies the demand of a group of consumers . The existence of a local control, independently of the main grid, defines a microgrid, which can be connected to or disconnected from the traditional power system working autonomously depending on the physical or economic conditions. This work presents two control methods for paralleling inverters in microgrids, droop control and masterslave control, in order to conduct a comparative study between both control techniques. Firstly, the concepts of distributed generation, microgrid and paralleled inverters are shown. Then, it is presented the theoretical fundamentals and main features of droop control and master-slave control. Finally, a comparison is done between both control techniques to allow define the best control technique. This comparison is done by means of simulations of a microrrede, analyzing its performance in the situations connected to the main grid, in islanding and during the disconnection transient. Also, it is observed the quantities behavior such as the current, the voltage amplitude and frequency and also the power shared among the inverters.
30

Dimensionamento de um sistema fotovoltaico conectado à rede a partir das características de inclinação e orientação dos módulos fotovoltaicos / Design of a grid-connected photovoltaic system from the photovoltaic modules tilt and azimuth angles characteristics

Paiva, Gabriel Mendonça de 03 June 2016 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2016-10-18T20:19:54Z No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2016-10-19T16:18:31Z (GMT) No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-10-19T16:18:31Z (GMT). No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-06-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study aimed to evaluate the design of a grid-connected photovoltaic (PV) system according to the positioning of the modules which compose the generator depending on tilt and azimuth angles in Goiânia, Goiás. In that purpose, a review of the literature was carried out concerning the main methods of inverter sizing ratio analysis applied to grid-connected PV systems. Starting from an hourly average climate measurement database from Goiania, an algorithm was developed to search for the ideal local inverter sizing ratio, considering the use of polycrystalline module technology. The parameters used in the analysis were provided by the manufacturers of the componentes used in the grid-connected PV system in installation at the Electrical, Mechanical and Computational Engineering School (EMC) from Federal University of Goias (UFG), which nominal power is 33.84 kWp. An inverter sizing ratio band of 0.54 to 0.77 was obtained for a -90° to +90° azimuth angle variation and 0° to 90° tilt angle variation. The potential of financial indicators improvement was verified and it was estimated a potential reduction in the levelized cost of energy above 10% comparing the inverter sizing ratio improved system to an unitary inverter sizing ratio system. / Este estudo tem como objetivo avaliar o dimensionamento de um sistema fotovoltaico conectado à rede (SFCR) de acordo com o posicionamento dos módulos que compõem o gerador quanto ao ângulo de inclinação e ao ângulo azimutal em Goiânia, Goiás. Para isso foi realizada uma revisão da literatura quanto às principais metodologias de análise do fator de dimensionamento do inversor (FDI) aplicado a SFCRs. A partir de uma base de dados em intervalos horários de medições climáticas de Goiânia desenvolveu-se um algoritmo para busca do FDI ideal para a localidade, considerando o uso de módulos de silício policristalino (p-Si). Os parâmetros utilizados na análise foram os parâmetros fornecidos pelos fabricantes dos componentes utilizados no SFCR em instalação da Escola de Engenharia Elétrica, Mecânica e de Computação (EMC) da Universidade Federal de Goiás (UFG), cuja potência nominal é de 33,84 kWp. Os métodos de análise do FDI foram comparados e foi considerado mais adequado neste estudo o método das perdas máximas anuais por limitação de potência no inversor. A faixa de FDI obtida para uma variação de -90° a +90° no ângulo azimutal e de 0° a 90° no ângulo de inclinação foi da ordem de 0,54 a 0,77. O potencial de aprimoramento de indicadores financeiros por meio do FDI foi verificado e foi estimada uma potencial redução acima de 10% do custo da energia produzida comparando o aperfeiçoamento do FDI com um FDI unitário.

Page generated in 0.0348 seconds