• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 11
  • 11
  • 11
  • 11
  • 8
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 125
  • 118
  • 93
  • 89
  • 47
  • 43
  • 42
  • 41
  • 40
  • 39
  • 38
  • 37
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Confiabilidade dos testes de infiltração apical com azul de metileno, rodamina B e sistema de transporte de fluído em obturações de canais após o uso de curativo de hidróxido de cálcio

Christian Giampietro Brandão 01 April 2005 (has links)
Objetivou-se avaliar se o curativo de hidróxido de cálcio realmente apresenta influência no selamento de obturações de canais, realizadas com cimento de óxido de zinco e eugenol, utilizando-se o transporte de fluídos e a infiltração de corantes com azul de metileno e rodamina B. Foram utilizadas 70 raízes que tiveram seus canais obturados pela técnica da condensação lateral com cimento de óxido de zinco e eugenol, após o uso ou não do curativo de hidróxido de cálcio. A infiltração marginal apical foi avaliada utilizando-se, primeiramente, o sistema de transporte de fluído e, posteriormente, os mesmos espécimes foram imersos em corante, sendo uma metade em Rodamina B a 0,2% e a outra em azul de metileno a 0,5%. Os resultados obtidos mostraram que tanto com o sistema de transporte de fluído, como com a utilização da Rodamina B, o curativo de hidróxido de cálcio não teve qualquer influência no selamento apical das obturações. Todavia, os resultados foram significantes quando da marcação pelo azul de metileno, demonstrando haver interferência desse curativo, a qual tem sido relatada como que física e que, provavelmente, melhoraria a capacidade de selamento das obturações. A observação desse resultado isoladamente poderia levar a supor da possibilidade dessa ocorrência. Contudo, considerando-se que apenas os resultados utilizando o azul de metileno mostraram diferença estatisticamente significante entre os grupos com e sem uso de curativo, o mais sensato é concluir que o hidróxido de cálcio, muito provavelmente, tenha apresentado interação química com o azul de metileno, o que deve ter promovido sua descoloração (pela ação da alcalinidade do hidróxido de cálcio) e resultando, portanto, em dados não confiáveis. / Filling of the root canal system is the end of a sequence of cleaning, shaping and removing bacteria from root canals, and should seal them as more hermetic as possible. Many filling techniques and materials are continuously being developed, trying to reach a perfect seal of the root canal system. The necessity of testing such techniques and material produces a lot of papers analyzing biological and physical properties of root canal fillings. Apical sealing is the more tested physical property, although there is not standardization for it that could provide unquestionable results. Seventy roots canals were filled by the lateral condensation technique with zinc-oxide eugenol sealer, after the use or not of a intracanal medicament of calcium hydroxide paste. Apical marginal leakage was assessed firstly by a fluid transport system and, then, the roots were divided in two groups, being immersed in Rhodamine B or methylene blue dye solutions. Either the fluid transport system results as the Rhodamine B ones, showed no statistically influence of calcium hydroxide use in the sealing capacity of the root fillings. However, when methylene blue was used as tracer, the results were significant, indicating a direct influence of this root canal dressing in the quality of apical sealing of the fillings. This fact is usually explained as a physical action of calcium hydroxide, what should improve the apical sealing. If this finding would be analyzed solely, we could suppose and believe in it but, considering that only methylene blue test showed this statistically significant finding between dressing and no dressing groups, it\'s reasonable to conclude that a chemical interaction between calcium hydroxide and methylene blue should happen, making this tracer uncolored (through alkalinity action), giving us no trustable results at all.
22

"Estudo 'in vitro' da infiltração bacteriana em obturações radiculares em dentes bovinos (influência do uso do E.D.T.A. à 17% e do laser de Er:YAG e Nd:YAG"

Souza, Patrícia de Almeida Rodrigues da Silva e 08 December 2004 (has links)
Avaliou-se in vitro a infiltração da bactéria E.Faecalis no sentido coroa-ápice em obturações radiculares de dentes bovinos, variando-se a forma de remoção da smear layer. Noventa dentes foram limpos e 10mm radiculares foram utilizados neste experimento. As raízes foram instrumentadas pela técnica clássica com limas tipo K n.90, 110 e 120 sob irrigação abundante com solução de hipoclorito de sódio a 1%. Após, foram divididas em quatro grupos experimentais: Grupo I: aplicação do laser de Nd:YAG com 15Hz e 1,5W de potência, aplicado pelo método de contato, no sentido ápice –coroa, em movimentos helicoidais de retirada, com cinco segundos de aplicação por quatro vezes; GRUPO II: uso do laser de Nd:YAG à semelhança do GRUPO I, entretanto os parâmetros foram os seguintes: 15Hz, 2,0W; GRUPO III: representado pelo laser de Er:YAG utilizado com energia de 150mJ/10HZ em quatro aplicações de cinco segundos, aplicado da mesma forma que os grupos anteriores. GRUPO IV: realizou-se a remoção da “smear layer’ com a aplicação da solução de E.D.T.A a 17% por três minutos; GRUPO V e VI: nos dois grupos controle, positivo e negativo,a remoção da Sl foi realizada de forma semelhante ao grupo IV. Em seguida, realizou-se a obturação radicular pela técnica da condensação lateral e cimento AH Plus. Somente o grupo V foi obturado com um cone único sem cimento obturador. Foi desenvolvido um aparato especial para a análise da infiltração bacteriana que consistia dos seguintes passos: inclusão das raízes em tubos de plásticos tipo eppendorf, impermeabilização das raízes, esterilização em óxido de etileno, montagem posterior em frascos de vidro contendo no seu interior BHI estéril. Na porção superior do tubo de plástico, foram aplicados 500µL de E. faecalis ATCC 29212, padronizada em 5x105 UFC/mL. Todo esse conjunto foi armazenado em 37O.C. A infiltração bacteriana, verificada pela turvação do meio de cultura estéril, foi checada diariamente por um período de 21 dias. Aproximadamente 78% das amostras infiltraram. Na análise comparativa entre os grupos, o teste do Qui-quadrado, revelou diferença estatisticamente significante (p<0.05), assim para as comparações individuais foi aplicado o teste de Tukey, com diferenças entre os grupos II e III e entre os grupos II e IV 0,05). Quanto ao tempo necessário para a infiltração o teste de Kruskal- Wallis mostrou haver diferença estatisticamente significante entre os grupos (p<0,05). Para identificar em quais grupos existia essa diferença, o teste de Dunn foi utilizado revelando diferença estatisticamente significante apenas entre os grupos II e IV (p< 0,05). Assim concluiu-se que a obturação radicular pela técnica da condensação lateral com cimento AH Plus é incapaz de impedir a infiltração bacteriana quando exposta a um meio de cultura; em função da diferença do número de espécimes infiltrado em cada grupo, verificou-se que o tipo de tratamento da dentina influencia no grau de infiltração bacteriana; o uso do laser de ER:YAG e Nd:YAG nesses parâmetros não mostrou benefício quanto à diminuição da infiltração bacteriana. / This study assessed bacteria (E. Faecalis) penetration from crown to apex through root fillings in bovine teeth, according to the smear layer treatment. Ninety teeth were cleaned and 10mm of root cut to be used in the experiment. The canal was prepared using the classic instrumentation technique with 110, 120 and 130 Kerr files under 1% sodium hypoclorite. The teeth were divided into the following groups: I- Contact application of Nd:Yag laser – 15Hz and 1,5W - in the apex-crown direction during 5 seconds (four times). II- In this group the same laser beam was used (Nd:YAG), however, with 15 Hz and 2,0W. III- Er:YAG laser with an output of 150mJ, with repetition rate of 10 Hz in four applications of 5 seconds, with circular movements in the apex crown direction throughout the canal wall, for 20 seconds. IV- (20 teeth) In this group the smear layer was removed with 17% of EDTA solution during 3 minutes, in both control groups. Next, the root canals were filled using lateral condensation technique and AH Plus cement. In the group V the root canals were filled with just one point without cement to simulate a deficient sealing. A special device was developed to analyze the bacterial penetration as follows: root placement in eppendorf plastic tubes, impermeabilization, sterilization with ethylene oxide, and posterior set in vials with BHI sterile. On the upper part of the plastic tube was applied 500 µL of E. Faecalis ATCC 29212, standardized in 5X105 UFC/mL. All this set were stored at 36 oC. The bacterial penetration was determined according to the blurriness culture. , checked daily, for 21 days. In the comparative analysis among groups, the Chi-squared test revealed significant differences (p=0,0024). So, the comparative test of Tukey was performed, that showed differences between groups II and III and groups II and IV (p< 0,05). Regarding the necessary time for bacteria penetration the Kruskall-Wallis test depicted differences among the groups. The Dunn test identified the differences between groups II and IV (p<0,05)
23

Microinfiltração marginal em restaurações adesivas

Heiderscheidt, Elizabeth da Cunha January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-25T21:48:12Z (GMT). No. of bitstreams: 1 301892.pdf: 9913931 bytes, checksum: 6d5afa7aa0392841874f0fbfacfc66e7 (MD5) / Apesar da evolução nas características físico-mecânicas das resinas compostas, a contração gerada pela reação de polimerização continua sendo uma desvantagem, podendo levar a infiltração marginal e respostas pulpares adversas. Nesta pesquisa foi avaliado o efeito do uso de resinas compostas com baixa contração no índice de microinfiltração marginal em esmalte e dentina de restaurações Classe II. Para isso, em 60 pré-molares hígidos extraídos foram preparadas cavidades Classe II MOD padronizadas, com limites gengivais em dentina e esmalte. Os dentes preparados foram divididos em 6 grupos e restaurados com uma resina controle (G1- Filtek® Z350) ou uma de cinco resinas de baixa contração (G2- Filtek® Z350 XT; G3- Charisma® Opal; G4- IPS Empress® Direct; G5 - Tetric® N-Ceram e G6- Filtek® P90 à base de silorano). Todas foram utilizadas seguindo as recomendações de cada fabricante. Após 7 dias de armazenamento em água destilada, os espécimes foram submetidos a 500 ciclos térmicos (5°C a 55°C). Todas as superfícies foram impermeabilizadas com esmalte cosmético, deixando 1mm livre nas margens da restauração, e os protocolos para imersão em solução de nitrato de prata amoniacal foram seguidos. As amostras foram então seccionadas em sentido mésio-distal, fotografadas, e a porcentagem de microinfiltração marginal foi definida por meio de software específico. Os valores foram analisados estatisticamente pelos testes ANOVA e KrusKal-Wallis (p<0,05). Os resultados mostraram que em todos os grupos houve microinfiltração em esmalte e/ou dentina, com maiores índices em dentina. Em esmalte não houve diferença estatisticamente significativa entre os grupos, já em dentina os menores índices de microinfiltração foram obtidos por Filtek® P90. / Despite the progress in physical and mechanical properties of composites, the contraction generated by the polymerization reaction remains a disadvantage and can lead to leakage and adverse pulpal reactions. This study assessed the effect of the use of low shrinkage composite resins in the rate of marginal microleakage in enamel and dentin of Class II restorations. Thus, in 60 caries-free extracted premolars standardized Class II MOD cavities were prepared, with gingival floors on dentin and enamel. The prepared teeth were divided into 6 groups and restored with a control microhybrid resin (G1- Filtek® Z350) or one of five low shrinkage resins (G2- Filtek® Z350 XT; G3- Charisma® Opal; G4-IPS Empress® Direct; G5 - Tetric® N-Ceram and G6- Filtek® P90 silorane based). All were used following each manufacturer recommendations. After 7 days of storage in distilled water, the specimens were subjected to 500 thermal cycles (5°C to 55°C). All tooth surfaces were sealed with nail varnish to within 1mm from the restoration margins and protocols for immersion in ammoniacal silver nitrate were followed. The samples were then sectioned mesiodistally, photographed, and the percentage of microleakage was defined by means of specific software. Data were statistically analyzed with ANOVA and Kruskal-Wallis tests (p <0.05). Results revealed that all groups showed microleakage in enamel and/or dentin, with the highest rates in dentin. Evaluating the enamel margins there was no statistically significant difference between the groups, however the lowest microleakage rates in dentin were obtained by G6.
24

Avaliação do processo de infiltração da água em solo residual de Biotita-gnaisse para superfícies com diferentes declividades utilizando lisímetros /

Paes Junior, Nilton Santos. January 2013 (has links)
Orientador: George de Paula Bernardes / Banca: Paulo Valladares Soares / Banca: Heraldo Luiz Giacheti / Resumo: Este trabalho de pesquisa tem por objetivo geral avaliar o processo de infiltração da água em um solo típico da região do Vale do Paraíba, sob diferentes declividades da superfície, utilizando para isso um lisímetro de vídeo e um simulador de chuva, calibrado no próprio laboratório. O estudo se justifica pelo fato de o processo de infiltração ser um dos principais responsáveis pela manutenção do escoamento dos cursos d'água e também pela compreensão do comportamento desse tipo de solo ao longo de um evento de precipitação, frente a redução dos fatores de segurança. O solo residual de biotita gnaisse, caracterizado como um sílte de baixa plasticidade, foi seco, destorrado e então depositado no interior do lisímetro em camadas de 3cm, sendo então compactado com um soquete a altura de queda padronizada. No decorrer de ensaio, as parcelas de água foram avaliadas por meio de relações temporais e volumétricas, e o avanço da frente de umedecimento por meio de câmera filmadora. No laboratório, foram realizados ainda ensaios para a caracterização completa do material em diferentes instantes de reaproveitamento da amostra, além ainda de ensaios de permeabilidade e de sucção para determinação das curvas características, de distribuição de poros e de condutividade hidráulica. A modelagem numérica pelo método teórico de Green & Ampt (1911) apresentou respostas satisfatórias, com uma considerável aderência do modelo em relação aos dados obtidos experimentalmente, principalmente para a declividade de 5%. O modelo permitiu ainda a separação entre a frente de umedecimento e a zona de transmissão, regiões ao longo do perfil, completamente diferentes quanto ao grau de saturação e gradiente de potencial da água, onde foi possível observar a forma bastante clara a influência da declividade... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This research paper has the objective at evaluating the process of infiltration of water in a typical soil from de region of the Paraíba Vallery, on different slopes inclination, making use of a lysimeter and a rainfall simulator, calibrated in the laboratory. The model developed in the laboratory, consists of a lysimeter glass box and a simulated rainfall with spreaders, calibrated in the laborator. The study is justified by the fact that the process of infiltration is a majo contributor to the maintenance of the flow of water courses and also for understanding the behavior of this type of soil along a rainfall event, ahead of the reduction factors of safety. The residual soil biotite gneiss, characterized as silt low plasticity, was air dried and trimmed before insertion inside the lysimeter by layers of 3 cm, and then compacted with a socket drop height standardized. During the test, the parcels of water evaluated by volumeric and temporal relations, and advancement of the witting front through the movie camera. In laboratory tests were performed yet for full characterization of the material at different instants of reusing the sample, and further testing for permeability and suction for determination of the characteristic curves of pore size distribution and hydraulic conductivity. Numerical modeling by theoretical method of Green & Ampt (1911) showed satisfatory answers, with a considerable adherence of the model against data obtained experimentally, especially for the slope of 5%. The model also allowed the separation of the wetting front and the transmission zone, regions along the profile, completely different in the degree of saturation and water potential gradient, where we could see quite clearly the influence of slope on each one of these areas. The increased slope generated a slow advance of transmission zone in relation to the wetting... (Complete abstract click electronic access below) / Mestre
25

Avaliação in vitro da microinfiltração marginal em cavidades submetidas ao tratamento com laser de Er:YAG e restauradas com diferentes resinas compostas e sistemas adesivos

Noya, Márcia Sepúlveda 28 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-24T20:40:57Z No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-28T16:53:55Z (GMT) No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Made available in DSpace on 2013-05-28T16:53:55Z (GMT). No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / O objetivo desta pesquisa foi avaliar a microinfitração, através de lupa estereoscópica, em cavidades de Classe V, condicionadas por três métodos: 1) com ácido fosfórico a 35%, 2) com laser de Er:YAG, em freqüência única de 3 Hz e energias distintas, 100 mJ e 200 mJ e 3) irradiação com laser de Er:YAG nos parâmetros acima descritos + condicionamento ácido. Em seguida os dentes foram restaurados com resina composta microhíbrida Esthet-X (Dentsply) e Z 250 (3M) e diferentes sistemas adesivos, um com solvente a base de acetona (Prime & Bond) e o outro a base de álcool e água (Single Bond). Foram utilizados 100 dentes humanos e os preparos foram realizados na face vestibular com extensão cervical a 1-2 mm além da junção amelocementária. Depois de restaurados os dentes foram submetidos a termociclagem em água a 5ºC ± 2º C e 55ºC ± 2º C, com 5 segundos de intervalo e 30 segundos de imersão, num total de 500 ciclos e, em seguida, imersos em solução aquosa de nitrato de prata 50% por 2 horas, seguida da imersão em solução reveladora. Os dentes foram incluídos em resina acrílica e seccionados no sentido vestíbulo-lingual, dividindo assim a restauração em duas porções uma mesial e a outra distal. A avaliação da microinfiltração, em esmalte e cemento foi feita segundo escores de zero a três. Os resultados foram submetidos ao Teste de Kruskal-Wallis e a prova de Mann-Whitney, através dos quais foi possível concluir que, em esmalte, os grupos condicionados com ácido e aqueles que foram irradiados e em seguida condicionados e restaurados com o sistema adesivo a base de água apresentam ausência de microinfiltração, sendo os grupos apenas irradiados com laser de Er:YAG e restaurados com o sistema adesivo a base de acetona, os que mostraram os maiores valores de microinfiltração. Em cemento, os menores graus de microinfiltração foram observados nos dentes condicionados + irradiados + adesivo com solvente a base de água. Concluiu-se que tanto em esmalte quanto em cemento, o emprego do ácido fosfórico, associado ou não a irradiação laser, mostrou-se efetivo na diminuição da microinfiltração. Em esmalte, o sistema adesivo a base de água apresentou um melhor desempenho quando comparado aos adesivos a base de acetona. No entanto, em cemento, os diferentes solventes mostraram comportamento semelhante entre eles. Quando avaliou-se a microinfiltração em relação a margem cavitária, observouse que esta foi inferior em esmalte quando comparada ao cemento. / Salvador
26

Avaliação, por infiltração de corante, de tecnologias Laser em cirurgias paraendodônticas

Pozza, Daniel Humberto 09 September 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-09-05T18:42:41Z No. of bitstreams: 1 Tese_ODONTO_Daniel Humberto Pozza.pdf: 1111687 bytes, checksum: bc5a59201d288bf835e1e4c17e3fc3f3 (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-09-09T15:23:14Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Daniel Humberto Pozza.pdf: 1111687 bytes, checksum: bc5a59201d288bf835e1e4c17e3fc3f3 (MD5) / Made available in DSpace on 2013-09-09T15:23:14Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Daniel Humberto Pozza.pdf: 1111687 bytes, checksum: bc5a59201d288bf835e1e4c17e3fc3f3 (MD5) / CAPES / Visando ao aprimoramento técnico, os Laseres CO2, Er:Yag e Nd:Yag têm sido utilizados para os procedimentos cirúrgicos periapicais. Esta pesquisa avaliou, in vitro, por meio do teste de infiltração apical, por corante Rodomina B a 1% e morfometria computadorizada do programa Image Tool, 108 caninos humanos permanentes, submetidos a tratamento endodôntico e divididos em nove grupos: A-apicectomia por broca em 90 graus, retrocatividade por ultra-som e retro-obturação com MTA; B-apicectomia por broca em 90 graus, retrocatividade por ultra-som, retro-obturação com MTA e fusão apical por Laser CO2:(1W,CW/CVV e 45s);C-apicectomia por broca em 90 graus, com posterior fusão apical por Laser Nd:YAG( 150mJ, 10Hz e 60s); D-apicectomia por broca em 90 graus, com posterior fusão apical por Laser CO2 (1W,CVV/CVV e 45s; E-apical por Laser Er:YAG(400 mJ,40Hz e ~36,92s), com posterior fusão apical por Laser Nd: YAG(400mJ,10Hz e ~36,92s, com posterior fusão apical por Laser Nd: YAG:150mJ,10Hz e 60s;G-apicectomia por Laser CO2(5W,CVV/SP e ~31,42s, retrocavidade com ultra-som e retro- obturação com MTA; H- irradiação do extremo apical por Laser CO2(1VV,CVV/CVV e 45s);I- irradiação do extremo apical por Laser Nd: YAG(150 mJ,10Hz e 60s.A infiltração do corante ocorreu, em diferentes graus, para todas as amostras desta pesquisa,sendo menor nas sequências técnicas do grupo C(16,20%), B(17,24%)e F(17,84%, as melhores sequências técnicas para a realização de cirurgias paraendodônticas investigadas neste estudo. / Salvador
27

Inibição da migração de neutrófilos e da hipernocicepção pelo pré-condicionamento isquêmico remoto : participação da via L- arginina-NO-GMPc-CANAIS K + ATP / Remote ischemic preconditioning inhibits neutrophil migration and hypernociception : role of NO-CGMP-K+ATP channel pathway

Sousa Filho, Marcus Vinícius Ponte de January 2011 (has links)
SOUSA FILHO, Marcus Vinícius Ponte de. Inibição da migração de neutrófilos e da hipernocicepção pelo pré-condicionamento isquêmico remoto : participação da via L- arginina-NO-GMPc-Canais K+ATP. 2011. 128 f. Tese (Doutorado em Cirurgia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2014-03-21T14:33:50Z No. of bitstreams: 1 2011_tese_mvpsousafilho.pdf: 2936273 bytes, checksum: 80dd27073338a77c31509e26608741aa (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-03-21T14:34:56Z (GMT) No. of bitstreams: 1 2011_tese_mvpsousafilho.pdf: 2936273 bytes, checksum: 80dd27073338a77c31509e26608741aa (MD5) / Made available in DSpace on 2014-03-21T14:34:56Z (GMT). No. of bitstreams: 1 2011_tese_mvpsousafilho.pdf: 2936273 bytes, checksum: 80dd27073338a77c31509e26608741aa (MD5) Previous issue date: 2011 / The reperfusion injury (RI) occurs when there is de lay in restoring blood flow to organs and tissues. Among the strategies proposed to attenuate the RI i s the ischemic preconditioning (IPC), which consists of induction of brief ischemic periods fol lowed by reperfusion performed before the sustained ischemic insult. In the first part, this study aim ed to evaluate the role of nitric oxide (NO), cycli c guanosine monophosphate (cGMP) and ATP-sensitive po tassium channels (K + ATP ) in the inhibitory effect of hind limb IPC on the mice peritoneal cavi ty neutrophil migration (NM). In the second part, t he objective was to evaluate the potential systemic an tinociceptive effect of IPC in mechanical plantar hypernociception test (MPH; Von Frey) in rats and t o evaluate the involvement of NO, cGMP and K + ATP channels in this event. In the first part, the IPC was induced by hind limb ischemia for 10 min followed by 30 min of reperfusion in wild and knock out mice to inducible NO synthase (iNOS -/-). The leukocyte rolling (LR), leukocyte adhesion (LA) and NM were induced by ip administration of Carrageenan (Cg, 500 μ g/cavity) and results expressed in number of leukoc ytes/min, number of adherent leukocytes/100 μ m 2 cells and number of neutrophils x 10 6 /cavity, respectively. Different groups of animals were treated with saline (SAL), A minoguanidine (AG, sc, 100mg/kg), ODQ (ip, 8 μ mol/kg) or Glibenclamide (GBC, sc, 20 mg/kg) 30 min before IPC induction. Controls received the same treatment, but without IPC. In the second part , the IPC was induced by hind limb ischemia for 10 min followed by 30 min of reperfusion in male Wista r rats (180-200g). Cg (300 μ g, intraplantar) or Prostaglandin E 2 (PGE 2 - 400 ng, intraplantar) were used as hypernocicept ive stimulus on left paw immediately after induction of IPC in contralateral paw. Different groups of animals were treated 30 min before induction of IPC with AG (100 μ g/kg, intraplantar), LNMMA (50 μ g, intraplantar), ODQ (8 μ g, intraplantar) or GBC (160 μ g, intraplantar). Controls received the same treatm ents, but without IPC. The quantification of MPH was performed throug h subtraction strength/pressure (g) required to cause withdrawal of paw in contact with an apparatu s of eletronic von Frey mensuread before hypernociceptive stimulus, by measure obtained 3h a fter administration of Cg or PGE2. The LR, LA and NM induced by Cg in the peritoneal cavity were significantly (p <0,01) inhibited by hind limb IPC of wild animals (LR= 75.94%, LA= 56.51%, NM= 79.01 %), but these effects were not observed in animals iNOS -/-. The treatment of wild animals wit h AG and ODQ, but not with GBC, abrogated the inhibitory effect of IPC on NM induced by Cg. Treat ment of animals with AG, GBC or ODQ did not significantly alter the NM induced by Cg in the per itoneal cavity. We also observed that IPC did not alter the TNF- α , IL1- β and CXCL1 chemokine levels induced by Cg in the pe ritoneal cavity. The mechanical hypernociception induced by Cg or PGE2 i n left hind paw was significantly reduced (p <0,01) when IPC was performed in the right paw (55% and 68%). The treatment of animals with AG, LNMMA, ODQ or GBC, before IPC, abrogated the antino ciceptive effect of IPC. Treatment of animals with AG, LNMMA, ODQ or GBC did not significantly al ter the hypernociception induced by noxious stimulation. Our results show that IPC has an inhib itory effect on remote NM, with NO an important mediator involved in this process, probably through the cGMP pathway. This inhibitory effect of IPC does not depend on the opening of K + ATP channels, or inhibition of synthesis and/or releas e of pro- inflammatory cytokines. The elucidation of the mech anism by which IPC inhibits the NM may make important contributions to clinical situations wher e neutrophil infiltration is a complicating factor. The IPC also has a potent inhibitory effect on inflamma tory pain, with NO seems to be one important mediator involved in this protective effect of IPC, acting through the cGMP/K + ATP channel pathway. This is the first demonstration described in the li terature of systemic antinociceptive effect of IPC, and the elucidation of the mechanisms involved in this process is fundamental for pain management induced by several inflammatory stimuli. / A lesão de reperfusão (LR) ocorre quando há retardo do restabelecimento do fluxo sanguíneo para órgãos e tecidos. Dentre as estratégias propostas p ara atenuar a LR está o pré-condicionamento isquêmico (PCI), que consiste na indução de curtos períodos de isquemia seguidos de reperfusão realizados antes da isquemia prolongada. Na primeir a parte deste trabalho, o objetivo do estudo foi avaliar a participação do Óxido Nítrico (NO), guano sina monofosfato cíclico (GMPc) e canais de potássio sensíveis a ATP (K + ATP ) no efeito inibitório do PCI da pata posterior na migração de neutrófilos (MN) para cavidade peritoneal de camund ongos. Na segunda parte, o objetivo foi avaliar o potencial antinociceptivo sistêmico do PCI no teste de hipernocicepção plantar mecânico (HPM; Von Frey) em ratos, bem como avaliar o envolvimento do NO, GMPc e canais K + ATP neste evento. Na primeira parte, o PCI foi induzido através da isque mia da pata posterior direita por 10 min seguidos d e 30 min de reperfusão em camundongos selvagens e com deleção gênica da NO sintase induzível (NOSi -/-). O rolamento de leucócitos (RL), adesão de leucócitos (AL), bem como a MN foram induzidos através da administração ip de Carragenin a (Cg, 500 μ g/cavidade), sendo os resultados expressos em número de leucócitos/min, número de cé lulas aderidas/100 μ m 2 , e número de neutrófilos x 10 6 /cavidade, respectivamente. Diferentes grupos de an imais foram tratados com salina, Aminoguanidina (AG, sc, 100mg/kg), ODQ (ip, 8 μ mol/kg) ou Glibenclamida (GBC, sc, 20mg/kg) 30 min antes da indução do PCI. Os controles receberam o mesmo tratamento, porém sem PCI. Na segunda parte, o PCI foi induzido através da isquem ia da pata posterior direita de ratos machos Wistar (180-200g) por 10 min seguidos de 30 min de reperfusão. Cg (300 μ g, intraplantar) ou Prostaglandina E 2 (PGE 2 – 400 ng, intraplantar) foram utilizadas como estí mulo hipernociceptivo na pata esquerda imediatamente após a indução do PCI n a pata contralateral. Diferentes grupos de animais foram tratados 30 min antes da indução do P CI com AG (100mg/kg, sc), LNMMA (50 μ g, intraplantar), ODQ (8 μ g, intraplantar) ou GBC (160 μ g, intraplantar). Os controles receberam os mesmos tratamentos, porém sem PCI. A quantificação da HPM foi realizada através da subtração da força /pressão (g) necessária para provocar a retir ada da pata em contato com o aparelho de von Frey eletrõnico mensurada antes do estímulo hiperno ciceptivo, pela medida obtida 3h após a administração do estímulo. O RL, AL e MN induzidos por Cg na cavidade peritoneal foram significativamente (p<0,01) inibidos pelo PCI da pa ta posterior dos animais selvagens (RL= 75,94%, AL= 56,51%, MN= 79,01%), o mesmo não sendo observad o nos animais NOSi -/-. O tratamento dos animais selvagens com AG e ODQ, mas não com GBC, an ularam o efeito inibitório do PCI sobre a MN induzida por Cg. O tratamento dos animais com AG , ODQ ou GBC não alterou significativamente a MN induzida por Cg na cavidade peritoneal. Observ ou-se ainda que o PCI não alterou os níveis de TNF- α , IL1- β e quimiocina CXCL1 induzidos por Cg na cavidade pe ritoneal. A hipernocicepção mecânica induzida por Cg ou PGE 2 na pata posterior esquerda foi reduzida significat ivamente (p<0,01) quando se realizou o PCI na pata direita ( 55% e 68%), sendo o efeito antinociceptivo do PCI anulado quando os animais foram tratados com AG, LN MMA, ODQ ou GBC antes do PCI. O tratamento dos animais com AG, LNMMA, ODQ ou GBC nã o alterou significativamente a hipernocicepção induzida pelos estímulos nociceptiv os. Nossos resultados demonstram que o PCI apresenta um efeito inibitório na MN a distância, s endo o NO um importante mediador envolvido neste processo, provavelmente através da via GMPc. Este e feito inibitório do PCI parece não depender da abertura de canais K + ATP , nem da inibição da síntese e/ou liberação de cito cinas pro-inflamatórias. O esclarecimento do mecanismo através do qual o PCI i nibe a MN poderá trazer importantes contribuições em situações clínicas onde a infiltra ção neutrofílica constitui um fator complicador. O PCI apresenta ainda um potente efeito inibidor na d or inflamatória, parecendo ser o NO um importante mediador envolvido neste efeito protetor do PCI, atuando através da via GMPc / canais K + ATP . Esta é a primeira demonstração descrita na litera tura do efeito antinociceptivo sistêmico do PCI, sendo o esclarecimento dos mecanismos envolvid os neste processo fundamental para manuseio da dor induzida pelos mais diversos estímulos.
28

Produção de feijão caupi (Vigna unguiculata (L.) Walp) através da infiltração subsuperficial de esgoto doméstico em solo arenoso / Cowpea beans production (Vigna unguiculata (L.) Walp), through the sub-superficial infiltration of domestic sewage into sandy soil

Lima, Paulo César Cunha 25 November 2005 (has links)
LIMA, P. C. C. Produção de feijão caupi (Vigna unguiculata (L.) Walp) através da infiltração subsuperficial de esgoto doméstico em solo arenoso. 2005. 91 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-28T15:56:51Z No. of bitstreams: 1 2005_dis_pcclima.pdf: 8111052 bytes, checksum: 241de67f8c1ed8470202316fc3b270f9 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-06-01T17:56:36Z (GMT) No. of bitstreams: 1 2005_dis_pcclima.pdf: 8111052 bytes, checksum: 241de67f8c1ed8470202316fc3b270f9 (MD5) / Made available in DSpace on 2016-06-01T17:56:36Z (GMT). No. of bitstreams: 1 2005_dis_pcclima.pdf: 8111052 bytes, checksum: 241de67f8c1ed8470202316fc3b270f9 (MD5) Previous issue date: 2005-11-25 / The production of cowpea beans (Vigna unguiculata (L.) Walp.) was evaluated in a real scale in this research project, by using the disposal of domestic sewage into the soil through the sub-superficial infiltration. The research was carried out during two periods. The first one was in the rainy season from January to April, and the second one in the dry season from August to November, 2004. The physical structure of the experimental station was built at the Horticulture Sector of the Agrarian Sciences Center, on the Pici Campus of the Federal University of Ceará, Fortaleza – CE, and was composed of six masonry seedbeds made of ceramic bricks with the following dimensions: 11m long, 1m wide, 0,60m deep, and 1% slant. The seedbeds were waterproofed with a black plastic blanket of 250 μ. The soil material used for the filling of the seedbeds was removed from a nearby area located by the place of the experiment. For comparative analysis, the six seedbeds were divided into two groups of three each. The first one was irrigated with underground water pumped from a deep well located in the place of the experiment, and the second one was irrigated with domestic sewage pumped from the sewage collecting pipe, which goes through the Pici Campus. The water volume used in the irrigation of the seedbeds was of 0,70 m³/day. The seedbeds were still divided into 2m sectors in order to better to evaluate the production along the seedbeds. The production was evaluated through the counting of the number of seeds and pods, and the productivity was assessed by the weight of seeds per useful area of 10,00m² located in each seedbed. In the rainy season, the seedbeds irrigated with domestic sewage presented average seed production data of 248,52 Kg ha-1, and the ones irrigated with raw water showed an average production of 1.377,52 Kg ha-1. The average productivity of grains in the dry season was of 767,08 Kg.ha-1 in the seedbeds irrigated with domestic sewage, and 757,43 Kg.ha-1 in the ones irrigated with water. The domestic sewage, despite being an alternative source of water and nutrients for the plants, cares regarding the agricultural handling should be considered to avoid risks to the environment and the health of the population. It was concluded, therefore, that the disposal of domestic sewage into the soil through the sub-superficial infiltration contributed to a larger production of cowpea beans, which makes this practice advisable in small rural communities, mainly in the semi-arid region of the Brazilian northeast / A produção de feijão caupi (Vigna unguiculata (L.) Walp.) foi avaliada, em escala real neste projeto de pesquisa, utilizando-se a disposição de esgoto doméstico no solo através da infiltração subsuperficial. A pesquisa foi realizada em dois períodos. O primeiro, na estação chuvosa, durante os meses de janeiro a abril e o segundo, no período de estiagem, durante os meses de agosto a novembro de 2004. A estrutura física da estação experimental foi construída nas dependências da horticultura do Centro de Ciências Agrárias, no Campus do Pici da Universidade Federal do Ceará, Fortaleza-CE, sendo constituída por seis canteiros de alvenaria de tijolos cerâmicos nas dimensões: 11m de comprimento, 1m de largura, 0,60m de profundidade e inclinação de 1%. Os canteiros foram impermeabilizados com manta plástica preta de 250 μ. O material de solo utilizado para o preenchimento dos canteiros foi retirado de uma área de empréstimo existente nas proximidades do local do experimento. Para análise comparativa, os seis canteiros foram divididos em dois grupos de três. O primeiro foi irrigado com água subterrânea bombeada de um poço amazonas, existente no local do experimento e o segundo irrigado com esgoto doméstico bombeado da rede coletora de esgotos que passa pelo Campus do Pici. A taxa de aplicação das águas de irrigação foi de 0,70 m3/dia, satisfazendo às necessidades hídricas das plantas. Os canteiros foram divididos, ainda, em seções de 2 metros para melhor avaliar a produção ao longo dos canteiros. A produção foi avaliada através da contagem do número de sementes e vagens e a produtividade pelo peso de sementes por área útil de 10m2 existente em cada canteiro. Os canteiros irrigados com esgoto doméstico, no período chuvoso, apresentaram dados de produção de sementes de 248,52 Kg.há-1 e 1.377,52 Kg.há-1, respectivamente, em relação aos irrigados com água. A produtividade de grãos, no período de estiagem foi de 767,08 Kg.há-1 nos canteiros irrigados com esgoto doméstico e nos irrigados com água de 757,43 Kg.há-1. O esgoto doméstico, mesmo sendo uma fonte alternativa de água e nutrientes para as plantas, cuidados referentes ao manejo agrícola devem ser considerados para evitar riscos ao meio ambiente e à saúde da população. Concluiu-se, portanto, que a disposição de esgoto doméstico no solo através da infiltração subsuperficial, colaborou para melhor produção de feijão caupi, o que torna recomendável está prática em pequenas comunidades rurais, principalmente no semi-árido do nordeste brasileiro
29

Adaptação marginal em restaurações classe II de resina bulk fill

Schünemann, Fernanda Haverroth January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-06-27T04:20:45Z (GMT). No. of bitstreams: 1 346673.pdf: 2220949 bytes, checksum: 28a4132d48728ad0159dc9723910cbf0 (MD5) Previous issue date: 2017 / O objetivo deste estudo foi avaliar a adaptação marginal em margens de esmalte e dentina de restaurações classe II com resina composta convencional (Gc), resina bulk fill (Gb) e resina bulk fill flow (Gf), após envelhecimento por ciclagem térmica e mecânica. Foram confeccionadas cavidades mésio-ocluso-distal (MOD) em 21 molares humanos (n=7) com 4 mm de profundidade na caixa oclusal, 3 mm de largura em toda a cavidade, margem em esmalte posicionado 1 mm aquém da junção amelo-cementária (JAC) margem em dentina 1 mm além da JAC. O mesmo sistema adesivo foi utilizado em todos os grupos e os incrementos foram fotopolimerizados de acordo com as recomendações do fabricante. As amostras foram envelhecidas em ciclagem térmica (500 ciclos) e em ciclagem mecânica (força oclusal de 200 N por 250.000 ciclos). Após envelhecimento, a margem da restauração foi avaliada segundo critérios para avaliação de fendas da Federação Dentária Internacional (FDI). Posteriormente, as amostras foram recobertas com esmalte para unhas, um milímetro aquém da margem da restauração e imersos em nitrato de prata por 24h, posteriormente em solução reveladora por 8h. Foram realizados dois cortes no sentido mésio-distal e selecionado a fatia com maior infiltração de prata. A fatia foi fotografada para análise da microinfiltração. Após realizadas as fotografias, as fatias foram desidratadas e recobertas com carbono para análise da nanoinfiltração (teste EDS). Os dados foram analisados pelo teste Kolmogorov-Smirnov, Kruskal-Wallis e Mann-Whitney (p<0,05). Quanto ao comportamento do substrato, para todos os testes as margens em esmalte apresentaram menores valores do que as margens em dentina (estatisticamente significante). Quanto ao comportamento do material, para o teste de avaliação de fendas não houve diferença estatisticamente significante entre os grupos. Para o teste de nanoinfiltração, houve diferença estatisticamente significante entre os três grupos em dentina, sendo que Gc apresentou menores valores de microinfiltração e Gf maiores valores. Para o teste EDS também houve diferença estatisticamente significante em dentina, no qual Gc apresentou os menores valores e Gb os maiores valores. Conclui-se que as resinas bulk fill e bulk fill flow apresentaram comportamento similar à resina composta convencional quanto ao esmalte. Já em dentina, o comportamento das resinas bulk fill e bulk fill flow foi inferior ao das resinas convencionais.<br> / Abstract : The objective of this study was to evaluate the marginal adaptation in enamel and dentin margins in Class II restorations with conventional composite resin (Gc), bulk fill resin (Gb) and bulk fill flow resin (Gf), after aging by thermal and mechanical cycling. Mesial-occlusal-distal cavities (MOD) were made in 21 human molars (n = 7), with 4 mm of depth in the occlusal box, 3 mm of width in the whole cavity, margin in enamel positioned 1 mm below the cementoenamel junction (JAC) margin in dentin 1 mm beyond JAC. The same adhesive system was used in all the groups and the increments were photopolymerized according to the manufacturer's recommendations. The samples were aged in thermal cycling (500 cycles) and in mechanical cycling (occlusal strength of 200 N per 250,000 cycles). After aging, the margin of the restoration was evaluated according to the criteria for the International Dental Federation (IDF) slit evaluation. Subsequently, the samples were covered with nail polish, one millimeter short of the restoration?s margin and immersed in silver nitrate for 24 hours, then in revealing solution for 8 hours. Two cuts were made in the mesio-distal direction and the slice with greater silver infiltration was selected. The slice was photographed for microleakage analysis. After the photographs were taken, the slices were dehydrated and covered with carbon for nanoinfiltration analysis (EDS test). Data were analyzed by the Kolmogorov-Smirnov, Kruskal-Wallis and Mann-Whitney test (a = 0.05). Regarding the behavior of the substrate, for all the resins, the enamel presented lower values in the FDI, microleakage and nanoinfiltration (statistically significant) than the dentin margins. As for the behavior of the material, Gc presented lower values in FDI, microleakage and nanoinfiltration (statistically significant) than Gb and Gf. When comparing the behavior of Gb and Gf, in all tests the first one obtained smaller values for enamel margins, while the second one obtained lower values for dentin margins only in the nanoinfiltration test (Gb dentine: 17.43% Gf dentin: 14.61%). It is concluded that Gc presents better behavior in relation to the marginal adaptation to margins in enamel and dentin. Gb presents better enamel behavior when compared to Gf, however, Gf presents better behavior in dentin.
30

Avaliação do processo de infiltração da água em solo residual de Biotita-gnaisse para superfícies com diferentes declividades utilizando lisímetros

Paes Junior, Nilton Santos [UNESP] 25 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-25Bitstream added on 2014-06-13T18:54:25Z : No. of bitstreams: 1 paesjunior_ns_me_bauru.pdf: 4613570 bytes, checksum: f7b2581cd54d242e3a23837852c5e7a8 (MD5) / Este trabalho de pesquisa tem por objetivo geral avaliar o processo de infiltração da água em um solo típico da região do Vale do Paraíba, sob diferentes declividades da superfície, utilizando para isso um lisímetro de vídeo e um simulador de chuva, calibrado no próprio laboratório. O estudo se justifica pelo fato de o processo de infiltração ser um dos principais responsáveis pela manutenção do escoamento dos cursos d'água e também pela compreensão do comportamento desse tipo de solo ao longo de um evento de precipitação, frente a redução dos fatores de segurança. O solo residual de biotita gnaisse, caracterizado como um sílte de baixa plasticidade, foi seco, destorrado e então depositado no interior do lisímetro em camadas de 3cm, sendo então compactado com um soquete a altura de queda padronizada. No decorrer de ensaio, as parcelas de água foram avaliadas por meio de relações temporais e volumétricas, e o avanço da frente de umedecimento por meio de câmera filmadora. No laboratório, foram realizados ainda ensaios para a caracterização completa do material em diferentes instantes de reaproveitamento da amostra, além ainda de ensaios de permeabilidade e de sucção para determinação das curvas características, de distribuição de poros e de condutividade hidráulica. A modelagem numérica pelo método teórico de Green & Ampt (1911) apresentou respostas satisfatórias, com uma considerável aderência do modelo em relação aos dados obtidos experimentalmente, principalmente para a declividade de 5%. O modelo permitiu ainda a separação entre a frente de umedecimento e a zona de transmissão, regiões ao longo do perfil, completamente diferentes quanto ao grau de saturação e gradiente de potencial da água, onde foi possível observar a forma bastante clara a influência da declividade... / This research paper has the objective at evaluating the process of infiltration of water in a typical soil from de region of the Paraíba Vallery, on different slopes inclination, making use of a lysimeter and a rainfall simulator, calibrated in the laboratory. The model developed in the laboratory, consists of a lysimeter glass box and a simulated rainfall with spreaders, calibrated in the laborator. The study is justified by the fact that the process of infiltration is a majo contributor to the maintenance of the flow of water courses and also for understanding the behavior of this type of soil along a rainfall event, ahead of the reduction factors of safety. The residual soil biotite gneiss, characterized as silt low plasticity, was air dried and trimmed before insertion inside the lysimeter by layers of 3 cm, and then compacted with a socket drop height standardized. During the test, the parcels of water evaluated by volumeric and temporal relations, and advancement of the witting front through the movie camera. In laboratory tests were performed yet for full characterization of the material at different instants of reusing the sample, and further testing for permeability and suction for determination of the characteristic curves of pore size distribution and hydraulic conductivity. Numerical modeling by theoretical method of Green & Ampt (1911) showed satisfatory answers, with a considerable adherence of the model against data obtained experimentally, especially for the slope of 5%. The model also allowed the separation of the wetting front and the transmission zone, regions along the profile, completely different in the degree of saturation and water potential gradient, where we could see quite clearly the influence of slope on each one of these areas. The increased slope generated a slow advance of transmission zone in relation to the wetting... (Complete abstract click electronic access below)

Page generated in 0.0863 seconds