761 |
Estudo de compatibilidade entre atorvastatina e excipientes por t?cnicas t?rmicas (TG, DSC) e FTIR utilizando correla??o de pearson / Study of compatibility between atorvastatin and excipients by thermal techniques (TG, DSC) and FTIR using pearson correlationSilva, Edilamar Pereira da 29 July 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-03-20T21:49:25Z
No. of bitstreams: 1
EdilamarPereiraDaSilva_DISSERT.pdf: 3623493 bytes, checksum: a0b5d0f1284a116519496496c1ba17b3 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-23T18:49:31Z (GMT) No. of bitstreams: 1
EdilamarPereiraDaSilva_DISSERT.pdf: 3623493 bytes, checksum: a0b5d0f1284a116519496496c1ba17b3 (MD5) / Made available in DSpace on 2017-03-23T18:49:31Z (GMT). No. of bitstreams: 1
EdilamarPereiraDaSilva_DISSERT.pdf: 3623493 bytes, checksum: a0b5d0f1284a116519496496c1ba17b3 (MD5)
Previous issue date: 2016-07-29 / A atorvastatina ? um medicamento antilip?mico do grupo das estatinas, de grande import?ncia para a preven??o de doen?as cardiovasculares e normalmente usada como atorvastatina de c?lcio. O objetivo deste trabalho foi caracterizar a atorvastatina e estudar poss?veis intera??es desta com v?rios excipientes por DSC, TG e FT-IR. As curvas DSC foram obtidas usando o calor?metro SHIMADZU, modelo DSC-60, em cadinho de alum?nio sob raz?o de aquecimento de 20 ?C min-1, em uma temperatura de 25-400 ?C. As curvas foram analisadas usando o software TASYS da SHIMADZU. Os espectros das amostras foram obtidos em um espectrofot?metro ATR-FTIR modelo IRprestige-21 da Shimadzu, no comprimento de onda de 700 a 4000 cm-1 em uma m?dia de 20 varreduras. Avaliou-se a const?ncia espectral da atorvastatina e misturas bin?rias fazendo-se uma correla??o linear entre o espectro te?rico das amostras e o espectro real obtido em temperatura ambiente (25 ?C). O espectro te?rico foi obtido utilizando um algoritmo ad hoc. Por DSC avaliamos intera??es com manitol e laurilsulfato de s?dio, j? que houve desaparecimento do pico do f?rmaco e aparecimento apenas do pico do excipiente, caracterizando intera??o. A partir da avalia??o da correla??o de Pearson, n?o observamos intera??es f?sicas com os excipientes, glicolato de amido, amido pr? gelatinizado, croscarmelose, estearato de magn?sio e lactose, uma vez que o valor do r ficou entre 0,8 e 1,0, portanto boa correla??o. H? intera??es f?sicas com o laurilsulfato de s?dio. Assim, os resultados obtidos por DSC s?o confirmados por FTIR mostrando-se. Essas t?cnicas mostram-se extremamente efetivas no estudo de pr?-formula??o. / Atorvastatin is an antilipemic drug from the statins? group that has a great importance to prevent cardiovascular disease and it is usually used as atorvastatin calcium. The aim of this study was to characterize the atorvastatin and studying possible interactions with different excipients by DSC, TG and FTIR. DSC curves were obtained using a Shimadzu calorimeter, model DSC-60, aluminum pan, under heating rate of 20 ?C min-1 at temperature of 25-400 ?C. Consequently, curves were analyzed using TASYS software from Shimadzu. The spectra of the samples were obtained on a spectrophotometer ATR-FTIR (IRPrestige- 21 Shimadzu), between 700 and 4000 cm-1, on average of 20 scans. We evaluated the atorvastatin and binary mixtures? spectral steadiness by making a linear correlation between the theoretical spectra and the real ones obtained at room temperature (25 ?C). The theoretical spectra were obtained using an ad hoc algorithm. We evaluated by DSC that there are chemical interactions with mannitol and sodium lauryl sulfate because there was disappearance of the drug?s peak and appearance only of the excipients? peaks. With respect to the other excipients, there were only displacements of peaks suggesting physical interactions, it means no incompatibility. From the FTIR evaluation using Person?s correlation, it was not observed any physical interaction between atorvastatin and the following excipients: starch glycolate, pregelatinized starch, croscarmellose, magnesium stearate and lactose, since the value of r was between 0.8 and 1.0; in other words, it means a good correlation. Moreover, it was confirmed a physical interaction with the sodium lauryl sulfate. Finally, the results obtained by DSC were confirmed by FTIR data using the Person?s correlation, so both analytical techniques demonstrated to be extremelly important and effective tools for applying in a preformulation study.
|
762 |
Desenvolvimento de métodos físicos e químicos para distinção de amostras autênticas e falsificadas de sibutraminaKnobloch, Jéssica Gil January 2015 (has links)
O comércio ilegal de medicamentos é um problema mundial que afeta milhões de pessoas todos os anos. A inclusão digital contribui para a ascensão das vendas, transformando-se no principal veículo de comércio de medicamentos falsificados no mundo. No Brasil, o número de medicamentos contrabandeados apreendidos pela Polícia Federal aumentou nos últimos anos, principalmente, nas regiões Sul e Sudeste. Sendo que grande parte destes, entraram pelo país pelo Paraguai. Os medicamentos falsificados que predominam no Brasil são para tratamento de disfunção erétil e para perda de peso. O objetivo deste trabalho foi comparar amostras de sibutramina de origens distintas a fim de detectar falsificações e agrupar amostras com propriedades semelhantes, através da quantificação por Cromatografia líquida acoplada à espectrometria de massas (CL-EM); da identificação por espectroscopia de infravermelho (IV) e do perfil físico (determinação do peso médio e exames físicos dos pós e cápsulas). Fez-se previamente o perfil físico das amostras, no qual foi possível identificar grupos com características semelhantes, mas adquiridos por diferentes vias. No entanto, o perfil físico sozinho não é definitivo para determinar uma falsificação e muito menos determinar uma origem comum para a mesma. Na espectroscopia de IV observou-se que quase todas as amostras apresentaram sinais nas regiões características dos grupamentos químicos da sibutramina. Nesta análise, foi possível identificar quatro grupos distintos. Em relação ao método de CL-EM validado, ele se mostrou específico, linear, exato, preciso e robusto. Os resultados da análise por CL-EM revelaram que apenas uma das amostras ilegais da faixa de 90-110%. Duas amostras apresentaram teor acima e sete abaixo. Por fim, das doze amostras analisadas, apenas as duas originais e uma das ilegas apresentaram teor adequado. Assim, pudemos verificar que é muito fácil obter sibutramina de fontes ilegais e que estes medicamentos não têm qualidade. A divulgação destes resultados é a melhor maneira de desencorajar as pessoas a não utilizarem estas fontes para a obtenção de medicamentos. / The illegal trade in drugs is a global problem that affects millions of people every year. Digital inclusion contributes to the rise of the sale of these drugs, making internet the main option in the world. In Brazil, the number of smuggled drugs seized by the Federal Police increased in recent years, mainly in the South and Southeast regions. Since most of them have entered Brazil via Paraguay. Counterfeit drugs that predominate in Brazil are those used to treat erectile dysfunction and to promote weight loss. The objective of this study was to compare samples of sibutramine with different origins in order to detect counterfeits and grouping samples with similar properties through quantification by liquid chromatography coupled to mass spectrometry (LC-MS) in previously developed and validated method; identification by infrared spectroscopy (IR) and physical profile (determination of average weight and physical examinations powders and capsules). In order to do so, 12 samples were examined, two original products acquired from local pharmacies and 10 from internet and street vendors. Based on visual examination at least three potential sources of capsules were identified, but acquired from different sources. However, the physical profile alone cannot be used to identify counterfeit drugs. Using infrared spectroscopy we found out that almost all samples showed signals that could be attributed to sibutramine functional groups. Based on IR spectra, four groups were identified, with six, three, two and one brand. Regarding the LC-MS method validated, it proved to be showed specific, linear, accurate, precise and robust. The results of LC-MS analysis revealed that only one of the illegally acquired samples were within the 90-110%. Two samples were above and the other seven were bellows those limits. Overall we found out that is very easy to buy sibutramine in the informal market and most of them are of poor quality and maybe the publication of these data coulb be the best way to discourage people to seek these sources.
|
763 |
Optimalizace radiační ochrany s použitím metody "cost-benefit". Výpočet pro pracoviště ETE ČEZ, a. s. / Optimalization radiation protection with by using method "cost-benefit". Calculation for power plant Temelín ČEZ, a.s.FOLTÝN, Pavel January 2008 (has links)
Currently in the area of radiation protection, the principle ALARA (As Low As Reasonable Achievable) is being used. Through this principle the radiation burden of workers with ionising radiation is optimised. One of the economic tools used here is the {\clqq}cost-benefit analysis``. It is one of the first analytical methods which are recommended by the ICRP (International Commission on Radiological Protection) for optimising costs needed to secure radiation protection. The cost benefit analysis is a good and efficient economical tool. With the help of this method it is possible to do the optimisation as well as to prove it. It takes into consideration all significant economic and social factors that are prescribed and recommended. Especially, it can prove that all expositions are kept as low as they are reasonable achievable, while considering the economic angle. Basically, it is a conception which is applicable in all areas of the public as well as private sector, in all areas of human activity. In this thesis some particular examples of using the CBA at the NPP Temelín are shown and compared with the achieved level of RP. Based on that the ALARA system at our workplace is demonstrated. The CB analysis with its extended forms helps to make principal and continuous decisions, and it is an essential factor in protection from harmful effects of ionising radiation. Its main contribution lies in the areas where it is necessary to build additional technical or building barriers. It is very important in designing and building new workplaces with ionising radiation.
|
764 |
Estimativa da temperatura-emissividade de alvos com base em regressões de dados de sensoriamento remoto proximalGrondona, Atilio Efrain Bica January 2015 (has links)
O infravermelho termal (TIR - Thermal InfraRed) é uma porção do espectro eletromagnético com várias aplicações no Sensoriamento Remoto (SR), tais como: geologia, climatologia, análises de processos biológicos, análises geofísicas, avaliação de desastres e detecção de mudanças, entre outras. No TIR a emissão de radiação dos alvos é uma função não linear de duas variáveis, a emissividade e a temperatura do alvo, e a principal dificuldade é calcular/estimar tais variáveis separadamente e de forma confiável. Vários métodos foram desenvolvidos nas últimas décadas para mitigar esta indeterminação, mas independente do método todos tem a mesma deficiência, são desenvolvidos para aplicações específicas como o tipo de sensor, tipo de estudo, o alvo em análise, o número de alvos, tipo de clima, entre outros. Desta forma, o método a ser aplicado depende do estudo em questão, e para obter melhores resultados deve-se escolher o método que melhor se aplica ao problema estudado pelo analista. Neste trabalho, se propõe uma abordagem alternativa para estimar a temperatura e, portanto, a emissividade de um alvo em particular. A abordagem consiste em gerar regressões, em determinados comprimentos de onda, a partir da função linearizada da radiância para dados de laboratório de uma amostra de quartzo em diferentes temperaturas, medida sob condições controladas de humidade e temperatura do ambiente. As regressões visam modelar a variação na temperatura devido as variações na radiância do alvo, de modo a estimar a temperatura a partir da radiância em determinado comprimento de onda e sem o conhecimento prévio da emissividade do alvo. Os dados de laboratório foram divididos em dois grupos, treinamento e controle, no grupo de treinamento várias regressões polinomiais foram aplicados enquanto os dados de controle serviram para validar e avaliar as regressões. Foram realizados 5 experimentos: 1) dados de laboratório em comprimentos de onda específicos, 2) nos comprimentos de ondas centrais das bandas TIR-ASTER, 3) nas simulações das bandas TIR-ASTER, 4) com a simulação da atmosfera (seca e úmida) para as bandas simuladas TIRASTER e 5) numa imagem L1B TIR-ASTER da região de estudo e validado com o produto AST08. Como resultado, foi possível estimar a temperatura com erros menores que 0.2K para os dados de laboratório e com erro médio menor que 1.5K para imagens LIB TIR-ASTER. Além disso, o método requer apenas uma banda espectral na imagem, viabilizando sua aplicação em sensores termais monoespectrais. Resultados satisfatórios foram obtidos com uma regressão linear simples, e melhoram ao aumentar o comprimento de onda. No entanto, aumentando o comprimento de onda e, simultaneamente, o grau do polinômio da regressão os resultados também melhoram com relação a regressão linear, porém não são significativos, e desta forma o ajuste linear é a melhor opção. Desta forma, o método proposto se mostrou promissor, sinalizando que futuras pesquisas são necessárias. / The thermal infrared (TIR) is a portion of the electromagnetic spectrum with multiple remote Sensing applications in the field of geology, climatology, biological processes analysis, geophysical analysis, disaster assessment, change detection and many others. In TIR, radiation emission of the target is a nonlinear function of two unknowns – the emissivity and the temperature, and the main difficulty is to calculate/estimate these two variables separately and reliably. Several methods have been developed in the recent decades to mitigate this problem. However, regardless of the method, all have developed similar incapacities for specific applications such as the type of sensor, study type, the target in question, the number of targets, type of weather, among others. Thus, the method to be applied depends on the study in question and the best results can be reached choosing the best fit method for that problem. In this work, we propose an alternative approach for estimating the temperature, and therefore the emissivity, of a particular target. The approach consists of generating statistical regressions in some wavelengths from linearized radiance function of laboratory data from a quartz sample at different temperatures, measured under controlled conditions of humidity and room temperature. The aim of regressions is to model the variation in temperature due to the variations in the radiance of the target in order to estimate the temperature from radiance data on a certain wavelength and without prior knowledge of the target emissivity. Laboratory datasets were divided into two groups - training and control. In the training group, several polynomial regressions were applied while the control group served to validate and evaluate the regressions. Five experiments were performed: (1) laboratory data at specific wavelengths (2) the central wave lengths of ASTER-TIR bands (3) simulations of ASTER-TIR bands (4) simulation of the atmosphere (dry and wet) for simulated bands of ASTER-TIR and (5) an image L1B ASTER-TIR of the study area validated with the AST08 product. As a result, it was possible to estimate the temperature with errors less than 0.2K from laboratory data and with mean error less than 1.5K from L1B ASTER-TIR images. Furthermore, the method requires only a spectral band in the image, enabling their application in monospectral thermal sensors. Satisfactory results were obtained with a simple linear regression and improved by increasing the wavelength. However, increasing the wavelength and, simultaneously, the degree of polynomial regression the results also improve with respect to linear regression results, but this improvement is insignificant, and thus the linear fit is the best option. Thus, the proposed method has shown promise, signaling that further research is needed.
|
765 |
Utvärdering av 3D-positionsmätning baserad på IR-kamera tracking med Wii RemoteOlsson, Fredrik, Borg, Johannes January 2009 (has links)
Under det senaste halvåret har Nintendos Wii Remote uppmärksammats av forskare välden över. Det som är intressant är att den går att använda på en vanlig dator med Bluetooth och med hjälp av Wiimotens IR-kamera går det att skapa en motsvarighet till tryckkänsliga skärmar och dynamiskt genererade 3D-projektioner. För att göra detta krävs det metoder för triangulering av 3D-positioner. Detta examensarbete går ut på att ut-värdera Wiimotens tekniska prestanda för att se om den är tillräcklig för sådana applikationer. Till detta ingår även att ta fram metoder för triangulering och mätning av 3D-positioner. Resultaten tyder på att Wiimotens prestanda är tillräcklig för att göra 3D-positionsmätning i samband med tracking. Dock begränsas dess användningsområde till mindre ytor.
|
766 |
Sensor systems for positioning and identification in ubiquitous computingJayabharath Kumar, Suri January 2006 (has links)
Technologies for position sensing and identification are important to have in ubiquitous computing environments. These technologies can be used to track users, devices, and artefacts in the physical milieu, for example, locating the position of a cellular phone in av physical environment. The aim of this thesis was to survey and classify available technologies for location sensing and identification. We have made a literature study on both commercial and research-oriented systems and technologies for use in indoor and outdoor environments. We compared the characteristics of the underlying sensing technologies with respect to physical size, sensing method, cost, and accuracy. We conclude the thesis with a set of recommendations to developers and discuss the requirements on future sensing technologies and their use in mobile devices and environments.
|
767 |
Estudo das transiÃÃes de fase nos sistemas Cs4W11O35 e Rb4W11O35 submetidos a variaÃÃes de temperatura. / Study of phase transitions in Cs4W11O35 Rb4W11O35 systems and subjected to temperature variations.Janilson dos Santos Coelho 06 March 2015 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Os compostos Cs4W11O35 e Rb4W11O35 pertencem à classe dos bronzes hexagonais de valÃncia balanceada com fÃrmula geral ABxW3-xO9 (A = Cs, K, Rb, Cs, Tl; B = Bi, Nb, Ta, Zr, Sc, etc.). Estes materiais dielÃtricos tÃm atraÃdo um grande interesse, uma vez que eles exibem sucessivas transiÃÃes de fase, propriedades ferroelÃtricas e geraÃÃo de segundos harmÃnicos. Embora as estruturas dos cristais Cs4W11O35 e Rb4W11O35 nÃo sejam conhecidas ainda, estudos de difraÃÃo de raios-x mostraram que os hexatungstatos de potÃssio e rubÃdio sÃo isoestruturais e a simetria mais provÃvel à a estrutura ortorrÃmbica, Pbn21, Pbc21, Cmm2. A difraÃÃo de raios-x tambÃm mostrou que os compostos KNbW2O9, RbNbW2O9 e KTaW2O9 sÃo isoestruturais de estrutura ortorrÃmbica, Cmm2 polar sem centro de inversÃo. O objetivo do presente trabalho à investigar as propriedades vibracionais dos compostos Cs4W11O35 e Rb4W11O35 com um foco especial na dependÃncia dos modos vibracionais em baixas temperaturas atravÃs de espectroscopia infravermelha. Apresentamos medidas de infravermelho à temperatura e pressÃo ambiente, de fotoluminescÃncia e cÃlculos clÃssicos de dinÃmica de rede. Relatamos ainda neste trabalho resultados de medidas de espectroscopia Raman a baixas temperaturas no intervalo de 295-38 K e comparamos com medidas de infravermelho no intervalo de 473-73 K. O Cs4W11O35 foi dopado com um pequeno percentual, em torno de 2%, do metal de transiÃÃo Eu3+ com o objetivo de usÃ-lo como Ãon sonda para a realizaÃÃo de medidas de fotoluminescÃncia. Com este procedimento, observamos que o Eu3+, ocupa um sÃtio de baixa simetria. O Rb4W11O35 apresenta duas transiÃÃes de fase a baixas temperaturas, uma em torno de 200 K e outra em torno de 100 K, quando analisado por espectroscopia Raman e infravermelho. O Cs4W11O35 tambÃm apresenta duas transiÃÃes de fase a baixas temperaturas, uma em torno de 165 K e a outra em torno de 110 K, porÃm, tais transiÃÃes sÃo visÃveis somente na espectroscopia Raman; muito provavelmente os modos que sofrem aÃÃo destas transiÃÃes sÃo infravermelho inativos. Pelo fato da estrutura destes materiais ainda nÃo serem totalmente definidas na literatura utilizamos cÃlculos clÃssicos de dinÃmica de rede no K0,26WO3 (KNbW2O9), para analisar o Rb4W11O35 (Cs4W11O35). Uma vez que, tais compostos sÃo hexatungstatos e os mesmos possuem assinatura Raman muito similar, e o fato desses cÃlculos possuÃrem uma boa concordÃncia com os dados experimentais, o entendimento dos principais aspectos das propriedades vibracionais dos hexatungstatos de K0,26WO3 e KNbW2O9, possibilitou uma melhor compreensÃo das modificaÃÃes estruturais observadas por meio das mudanÃas nos espectros Raman e infravermelho dos compostos Rb4W11O35 e Cs4W11O35 durante os experimentos com variaÃÃo de temperatura. Um aspecto importante dos resultados dos cÃlculos vibracionais foi a previsÃo de modos vibracionais tipos tubulares relacionados Ãs cavidades hexagonais dos compostos K0,26WO3 e KNbW2O9. / The Rb4W11O35 and Cs4W11O35 compounds, belongs to the valence balanced hexagonal tungsten materials with ABxW3-xO9 stoichiometry (with A = Cs, K, Rb, Tl, and B = Bi, Nd, Ta, Zr, Sc, etc.) These materials present interesting physical properties like rich sequence of phase transitions (rich polymorphism), ferroelectric properties and second harmonic generation. Despite of the unknown structures, Rb4W11O35 and Cs4W11O35, of that systems (we mean spatial symmetry), X-ray experiments suggest that rubidium and cesium hexatungstates are isostructural with orthorhombic structure belonging possibly to Pbn21, Pbc21 or Cmm2 space group symmetry. In addition, X-ray diffraction showed that the KNbW2O9, RbNbW2O9 KTaW2O9 compounds are isostructural, crystallizing in the polar noncentrosymmetric space group Cmm2. The aim of this study was to investigate the vibrational properties of the compounds Cs4W11O35 and Rb4W11O35 with special focus on the dependence of vibrational modes with low temperature via infrared spectroscopy. We report in this work results light scattering low temperature experiment in the 295-38 K temperature range and comparing the measures in the infrared range 473-73 K. Also present IR spectra and photoluminescence investigation at room temperature and pressure and lattice dynamics phonons calculation in parent structure. The Cs4W11O35 was doped with a small percentage, 2%, Eu3+ transition metal aiming to use it as a probe to perform measurements of photoluminescence ion. With this procedure, we see that Eu3+, occupies a site of low symmetry. The Rb4W11O35 presents phase transitions at low temperatures, around 200 K and the other around 100 K when analyzed by light scattering and IR spectra. The Cs4W11O35 also present two phase transitions at lower temperatures, around 165 K and the other around 110 K, however, such transitions are visible only light scattering, the modes most likely to suffer action of these transitions are inactive IR. Because the structure of these materials are not known in the literature. We have utilized lattice dynamics phonon calculations on network K0,26WO3 (KNbW2O9) to analyze Rb4W11O35 (Cs4W11O35), since such hexatungstatos have very similar Raman signature such calculations have good agreement with experimental data. The objective of this study was to understand the main aspects of the vibrational properties of K0,26WO3 and KNbW2O9. These results allowed us to interpret the transformation mechanisms of the observed temperature induced phase transitions. The lattice dynamics calculations revealed the existence of radial and tangential motions of oxygen atoms belonging to the hexagonal cavities. The tubular like modes command the dynamics of phase transitions in hexagonal tungsten systems.
|
768 |
Obtenção e caracterização de blendas poliméricas de poli (ácido láctico-co-glicólico) e poli (isopreno) para aplicação como biomaterialMarques, Douglas Ramos January 2011 (has links)
A conformação de dispositivos médicos implantáveis a partir de uma blenda exige o desenvolvimento de um produto com propriedades próximas do comportamento ideal, combinando propriedades térmicas e mecânicas e boa resposta tecidual. O Poli (ácido láctico-co-glicólico) (PLGA) e o Poli (isopreno) (IR) foram escolhidos como componentes da blenda com finalidade de promover boa biocompatibilidade e características mecânicas especificas. As blendas foram obtidas por dissolução dos polímeros em solvente orgânico, seguida de secagem. Para determinar a influência do teor de IR sobre as propriedades da blenda, foram realizados ensaios de espectroscopia na região de infravermelho por transformada de Fourier (FTIR), calorimetria diferencial de varredura (DSC), análise dinâmico-mecânica (DMA), microscopia óptica por luz polarizada (POM), análise de dureza, ensaio de tração e análise de viabilidade celular. A presença de IR na blenda provocou alteração na estrutura molecular semi-cristalina do PLGA, bem como influenciou o comportamento mecânico analisado a partir da curva tensão-deformação do material. A blenda se mostrou biocompativel em ambiente celular e em ensaios preliminares em animais, apresentando potencial para aplicação como biomaterial. / The conformation of an implantable medical device from a polymeric blend requires the development of a product with properties as close as possible of ideal behavior with the combination between thermal and mechanical properties and good tissue response. The poly (lactic-co-glycolic acid) (PLGA) and the poly (isoprene) (IR) were chosen as the blend components to promote good biocompatibility and specific mechanical characteristics. The blends were obtained by dissolution of polymers in organic solvent, followed by drying. In order to determine the IR content influence over the blend properties, Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), polarized light optical microscopy (POM), hardness analysis, tensile test and cell viability test were carried out. The IR presence caused changes in semi-crystalline molecular structure of PLGA, as well as actuated over the mechanical response analyzed on material’s stress-strain curve. The blend showed itself biocompatible at cellular environment and at preliminary animal tests, presenting potential for application as biomaterial.
|
769 |
Estimativa da temperatura-emissividade de alvos com base em regressões de dados de sensoriamento remoto proximalGrondona, Atilio Efrain Bica January 2015 (has links)
O infravermelho termal (TIR - Thermal InfraRed) é uma porção do espectro eletromagnético com várias aplicações no Sensoriamento Remoto (SR), tais como: geologia, climatologia, análises de processos biológicos, análises geofísicas, avaliação de desastres e detecção de mudanças, entre outras. No TIR a emissão de radiação dos alvos é uma função não linear de duas variáveis, a emissividade e a temperatura do alvo, e a principal dificuldade é calcular/estimar tais variáveis separadamente e de forma confiável. Vários métodos foram desenvolvidos nas últimas décadas para mitigar esta indeterminação, mas independente do método todos tem a mesma deficiência, são desenvolvidos para aplicações específicas como o tipo de sensor, tipo de estudo, o alvo em análise, o número de alvos, tipo de clima, entre outros. Desta forma, o método a ser aplicado depende do estudo em questão, e para obter melhores resultados deve-se escolher o método que melhor se aplica ao problema estudado pelo analista. Neste trabalho, se propõe uma abordagem alternativa para estimar a temperatura e, portanto, a emissividade de um alvo em particular. A abordagem consiste em gerar regressões, em determinados comprimentos de onda, a partir da função linearizada da radiância para dados de laboratório de uma amostra de quartzo em diferentes temperaturas, medida sob condições controladas de humidade e temperatura do ambiente. As regressões visam modelar a variação na temperatura devido as variações na radiância do alvo, de modo a estimar a temperatura a partir da radiância em determinado comprimento de onda e sem o conhecimento prévio da emissividade do alvo. Os dados de laboratório foram divididos em dois grupos, treinamento e controle, no grupo de treinamento várias regressões polinomiais foram aplicados enquanto os dados de controle serviram para validar e avaliar as regressões. Foram realizados 5 experimentos: 1) dados de laboratório em comprimentos de onda específicos, 2) nos comprimentos de ondas centrais das bandas TIR-ASTER, 3) nas simulações das bandas TIR-ASTER, 4) com a simulação da atmosfera (seca e úmida) para as bandas simuladas TIRASTER e 5) numa imagem L1B TIR-ASTER da região de estudo e validado com o produto AST08. Como resultado, foi possível estimar a temperatura com erros menores que 0.2K para os dados de laboratório e com erro médio menor que 1.5K para imagens LIB TIR-ASTER. Além disso, o método requer apenas uma banda espectral na imagem, viabilizando sua aplicação em sensores termais monoespectrais. Resultados satisfatórios foram obtidos com uma regressão linear simples, e melhoram ao aumentar o comprimento de onda. No entanto, aumentando o comprimento de onda e, simultaneamente, o grau do polinômio da regressão os resultados também melhoram com relação a regressão linear, porém não são significativos, e desta forma o ajuste linear é a melhor opção. Desta forma, o método proposto se mostrou promissor, sinalizando que futuras pesquisas são necessárias. / The thermal infrared (TIR) is a portion of the electromagnetic spectrum with multiple remote Sensing applications in the field of geology, climatology, biological processes analysis, geophysical analysis, disaster assessment, change detection and many others. In TIR, radiation emission of the target is a nonlinear function of two unknowns – the emissivity and the temperature, and the main difficulty is to calculate/estimate these two variables separately and reliably. Several methods have been developed in the recent decades to mitigate this problem. However, regardless of the method, all have developed similar incapacities for specific applications such as the type of sensor, study type, the target in question, the number of targets, type of weather, among others. Thus, the method to be applied depends on the study in question and the best results can be reached choosing the best fit method for that problem. In this work, we propose an alternative approach for estimating the temperature, and therefore the emissivity, of a particular target. The approach consists of generating statistical regressions in some wavelengths from linearized radiance function of laboratory data from a quartz sample at different temperatures, measured under controlled conditions of humidity and room temperature. The aim of regressions is to model the variation in temperature due to the variations in the radiance of the target in order to estimate the temperature from radiance data on a certain wavelength and without prior knowledge of the target emissivity. Laboratory datasets were divided into two groups - training and control. In the training group, several polynomial regressions were applied while the control group served to validate and evaluate the regressions. Five experiments were performed: (1) laboratory data at specific wavelengths (2) the central wave lengths of ASTER-TIR bands (3) simulations of ASTER-TIR bands (4) simulation of the atmosphere (dry and wet) for simulated bands of ASTER-TIR and (5) an image L1B ASTER-TIR of the study area validated with the AST08 product. As a result, it was possible to estimate the temperature with errors less than 0.2K from laboratory data and with mean error less than 1.5K from L1B ASTER-TIR images. Furthermore, the method requires only a spectral band in the image, enabling their application in monospectral thermal sensors. Satisfactory results were obtained with a simple linear regression and improved by increasing the wavelength. However, increasing the wavelength and, simultaneously, the degree of polynomial regression the results also improve with respect to linear regression results, but this improvement is insignificant, and thus the linear fit is the best option. Thus, the proposed method has shown promise, signaling that further research is needed.
|
770 |
Aplicação da Técnica FT-NIR no Estudo do Comportamento de Frações Pesadas do Petróleo / Application of FT-NIR Technique in the Study of Behavior of Heavy Oil FractionsSilva, Leydy Daiana Frazão da 08 April 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:36Z (GMT). No. of bitstreams: 1
Leydy Daiana Frazao da Silva.pdf: 3169054 bytes, checksum: 7722a9e052abaed32aab639ad8ea0af9 (MD5)
Previous issue date: 2011-04-08 / Oil is a complex mixture whose composition and properties vary according to their origin and composition. Changes in pressure and temperature during production operations and processing can compromise the phase equilibrium of this mixture, resulting in the formation of solid precipitates. The deposition of these fractions can cause blockage of the reservoir and the drainage ducts causing damage to equipment and interfere with the quality of oil produced. Among the major heavy fractions with potential for the formation of deposits are asphaltenes. To treat this problem of asphaltene deposition is necessary to know more about their behavior in different oil samples. To obtain information of these precipitates Near Infrared spectroscopy coupled with Fourier transform was used to determine the onset of asphaltene precipitation in Brazilian petroleum, then these values beginning of precipitation were used to calculate the solubility parameters of the samples, the use of near infrared targets the improvement in the experimental determination of the start point of asphaltene precipitation obtained previously by optical microscopy. The results of solubility parameter obtained by the two techniques were compared. / O petróleo é como uma mistura complexa cuja composição e propriedades variam conforme a sua origem e composição. A deposição dos asfaltenos, frações pesadas do petróleo, durante a prospecção, transporte e processamento são indesejáveis devido aos enormes prejuízos que podem causar. Para compreender o problema de deposição dos asfaltenos é necessário o conhecimento melhor sobre seu comportamento nas diferentes amostras de petróleo. Visando obter mais informações desses precipitados, a Espectroscopia de Infravermelho Próximo acoplada à transformada de Fourier foi utilizada para determinar o ponto de início de precipitação (IP) dos asfaltenos em petróleos brasileiros. Posteriormente, esses valores de inicio de precipitação foram usados para calcular os parâmetros de solubilidade das amostras analisadas. A utilização do infravermelho próximo visa o aprimoramento na determinação experimental do ponto de início de precipitação dos asfaltenos, até então obtido por microscopia óptica. Os resultados mostraram que o ponto de início de precipitação e o parâmetro de solubilidade podem ser obtidos utilizando todo o espectro completo de absorbância, ao invés de utilizar apenas os dados do comprimento de onda de 1600 nm, usualmente empregado na literatura.
|
Page generated in 0.0601 seconds