• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 466
  • 215
  • 48
  • 20
  • 4
  • 1
  • 1
  • Tagged with
  • 733
  • 434
  • 181
  • 150
  • 112
  • 111
  • 93
  • 91
  • 83
  • 79
  • 68
  • 62
  • 60
  • 52
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Imagerie fonctionnelle du placenta en IRM / Functional Magnetic Resonance Imaging of the placenta

Alison, Marianne 17 December 2012 (has links)
L’insuffisance placentaire par défaut de vascularisation est une pathologie fréquente de la grossesse, de diagnostic difficile, avec des complications potentiellement graves (retard de croissance intra utérin, prééclampsie). L’objectif de ce travail de Thèse a été de développer l’IRM fonctionnelle multiparamétrique pour l’exploration du placenta à 4.7 T chez la rate gestante. Matériel et méthode : L’IRM de diffusion (SE- EPI DWI) avec analyse IVIM et l’IRM dynamique avec injection de gadolinium (DCE) et haute résolution temporelle (< 1s) ont été développées puis étudiées sur un modèle murin contrôlé d’hypoperfusion placentaire par ligature du pédicule vasculaire utérin gauche au 17ème jour de gestation. Les paramètres obtenus sur les placentas hypoperfusés de la corne gauche ligaturée étaient comparés à ceux des placentas normaux de la corne droite. L’effet de l’hyperoxygénation maternelle était étudié en diffusion. Résultats : Ont été étudiés 73 placentas, dont 23 pathologiques (n= 10 rates) en diffusion et 53 placentas, dont 11 pathologiques (n=12 rates) en DCE. Les paramètres significativement diminués du côté hypoperfusé étaient le coefficient apparent de diffusion (ADC), la fraction de perfusion (f) en diffusion et le flux sanguin maternel (F) en DCE. Sous hyperoxygénation maternelle, l’ADC et le coefficient de diffusion (D) augmentaient et f diminuait. Les paramètres obtenus en diffusion et en DCE n’étaient pas nettement corrélés entre eux. Conclusion : Un outil d’IRM fonctionnelle placentaire multiparamétrique a été développé à 4.7 T chez la rate gestante. La DWI comme la DCE apparaissent complémentaires pour le diagnostic d’hypoperfusion placentaire. / Placental insufficiency caused by deficient vascularization is common during pregnancy, difficult to diagnose and can lead to severe materno-fetal complications (intrauterine growth restriction, preeclampsia). The aim of this work was to develop multi-parametric functional magnetic resonance imaging (MRI) to assess the placenta at 4.7 T on a murine model. Materials and methods : Diffusion-weighted imaging (SE-EPI-DWI) with the intravoxel incoherent motion (IVIM) analysis and dynamic contrast enhanced MRI (DCE) with a high-time resolution (<1 s) were developed and evaluated on a controlled rat model of reduced placental perfusion, achieved by ligation of the left uterine vascular pedicle on the 17th embryonic day. Parameters from the placentas in the left ligated horn were compared to those from the normal placentas in the non ligated horn. The effect of maternal hyperoxygenation on placental microvascularization was studied with DWI.Results: For DWI, 73 placentas were examined, 23 from the ligated side (n=10 rats). For DCE, 53 placentas were analysed, 11 from the ligated side (n=12 rats). In the uterine horn with reduced perfusion, the apparent diffusion coefficient (ADC), the perfusion fraction (f) obtained with DWI and the placental blood flow (F) obtained with DCE were significantly decreased. Under maternal hyperoxygenation, ADC and the diffusion coefficient (D) increased whereas f decreased. DWI and DCE parameters were not significantly correlated with each other. Conclusion: Multi-parametric MRI has been developed for murine placental analysis at 4.7T. DWI and DCE are complementary tools for the diagnosis of reduced placental perfusion.
262

Towards real-time diffusion imaging : noise correction and inference of the human brain connectivity / Imagerie de diffusion en temps-réel : correction du bruit et inférence de la connectivité cérébrale

Brion, Véronique 30 April 2013 (has links)
La plupart des constructeurs de systèmes d'imagerie par résonance magnétique (IRM) proposent un large choix d'applications de post-traitement sur les données IRM reconstruites a posteriori, mais très peu de ces applications peuvent être exécutées en temps réel pendant l'examen. Mises à part certaines solutions dédiées à l'IRM fonctionnelle permettant des expériences relativement simples ainsi que d'autres solutions pour l'IRM interventionnelle produisant des scans anatomiques pendant un acte de chirurgie, aucun outil n'a été développé pour l'IRM pondérée en diffusion (IRMd). Cependant, comme les examens d'IRMd sont extrêmement sensibles à des perturbations du système hardware ou à des perturbations provoquées par le sujet et qui induisent des données corrompues, il peut être intéressant d'investiguer la possibilité de reconstruire les données d'IRMd directement lors de l'examen. Cette thèse est dédiée à ce projet innovant. La contribution majeure de cette thèse a consisté en des solutions de débruitage des données d'IRMd en temps réel. En effet, le signal pondéré en diffusion peut être corrompu par un niveau élevé de bruit qui n'est plus gaussien, mais ricien ou chi non centré. Après avoir réalisé un état de l'art détaillé de la littérature sur le bruit en IRM, nous avons étendu l'estimateur linéaire qui minimise l'erreur quadratique moyenne (LMMSE) et nous l'avons adapté à notre cadre de temps réel réalisé avec un filtre de Kalman. Nous avons comparé les performances de cette solution à celles d'un filtrage gaussien standard, difficile à implémenter car il nécessite une modification de la chaîne de reconstruction pour y être inséré immédiatement après la démodulation du signal acquis dans l'espace de Fourier. Nous avons aussi développé un filtre de Kalman parallèle qui permet d'appréhender toute distribution de bruit et nous avons montré que ses performances étaient comparables à celles de notre méthode précédente utilisant un filtre de Kalman non parallèle. Enfin, nous avons investigué la faisabilité de réaliser une tractographie en temps-réel pour déterminer la connectivité structurelle en direct, pendant l'examen. Nous espérons que ce panel de développements méthodologiques permettra d'améliorer et d'accélérer le diagnostic en cas d'urgence pour vérifier l'état des faisceaux de fibres de la substance blanche. / Most magnetic resonance imaging (MRI) system manufacturers propose a huge set of software applications to post-process the reconstructed MRI data a posteriori, but few of them can run in real-time during the ongoing scan. To our knowledge, apart from solutions dedicated to functional MRI allowing relatively simple experiments or for interventional MRI to perform anatomical scans during surgery, no tool has been developed in the field of diffusion-weighted MRI (dMRI). However, because dMRI scans are extremely sensitive to lots of hardware or subject-based perturbations inducing corrupted data, it can be interesting to investigate the possibility of processing dMRI data directly during the ongoing scan and this thesis is dedicated to this challenging topic. The major contribution of this thesis aimed at providing solutions to denoise dMRI data in real-time. Indeed, the diffusion-weighted signal may be corrupted by a significant level of noise which is not Gaussian anymore, but Rician or noncentral chi. After making a detailed review of the literature, we extended the linear minimum mean square error (LMMSE) estimator and adapted it to our real-time framework with a Kalman filter. We compared its efficiency to the standard Gaussian filtering, difficult to implement, as it requires a modification of the reconstruction pipeline to insert the filter immediately after the demodulation of the acquired signal in the Fourier space. We also developed a parallel Kalman filter to deal with any noise distribution and we showed that its efficiency was quite comparable to the non parallel Kalman filter approach. Last, we addressed the feasibility of performing tractography in real-time in order to infer the structural connectivity online. We hope that this set of methodological developments will help improving and accelerating a diagnosis in case of emergency to check the integrity of white matter fiber bundles.
263

Magnetic resonance microscopy of Aplysia neurons : studying neurotransmitter-modulated transport and response to stress / Microscopie par résonance magnétique des neurones d’aplysie : étude du transport actif en présence de neurotransmetteurs, et de la réponse au stress

Jelescu, Ileana O. 02 October 2013 (has links)
Les progrès technologiques récents en imagerie par résonance magnétique (IRM) ont ouvert la voie à une résolution spatiale de l’ordre de quelques microns, et donc à l’imagerie de cellules biologiques. Dans le cadre de ce projet, nous avons réalisé des expériences de microscopie IRM sur le système nerveux de l’aplysie (Aplysia californica), particulièrement adapté de par sa simplicité et de par la très grande taille de ses neurones, en vue d’étudier des processus à échelle cellulaire avec divers contrastes IRM. Les expériences d’imagerie ont été effectuées sur un aimant horizontal 17.2 Tesla, à des résolutions spatiales jusqu’à 25 µm isotrope. Le travail initial a consisté en la conception et fabrication de micro-antennes radiofréquences adaptées à la taille de neurones uniques et de ganglions. La première partie du projet a porté sur l’utilisation de l’ion manganèse (Mn2+) comme traceur de réseaux neuronaux dans le ganglion buccal de l’aplysie. Le manganèse (Mn) est un agent de contraste IRM qui pénètre dans les neurones par les canaux de calcium. La cartographie des projections axonales des neurones moteurs du ganglion dans chacun des nerfs périphériques a été établie. Il a également été démontré l’existence d’un transport actif du Mn2+ au sein du réseau neuronal activé par le neurotransmetteur dopamine. Dans un second temps, on s’est intéressé à deux méthodes de mesure de diffusion par IRM, à échelle microscopique. D’une part, un mécanisme de pondération en diffusion, DESIRE (Diffusion Enhancement of SIgnal and REsolution), original et particulièrement adapté à des échantillons petits, a été exploré. La séquence DESIRE a été implémentée en deux dimensions et testée avec succès sur fantôme. Le rehaussement mesuré était en accord avec les prévisions théoriques. Le grand défi à venir sera d’utiliser cette séquence pour acquérir des images de tissu biologique pondérées en diffusion avec un contraste unique. D’autre part, une séquence plus « classique » a été implémentée pour mesurer le coefficient de diffusion apparent (ADC) dans le tissu nerveux. Il s’agit d’une DP-FISP (Diffusion Prepared Fast Imaging with Steady-state free Precession) en trois dimensions, qui répond aux critères de résolution spatiale et de rapidité, avec un minimum d’artefacts. Cette séquence a permis d’étudier l’évolution de l’ADC de l’eau à différentes échelles du tissu nerveux en réponse à un stress cellulaire. Les deux sollicitations retenues étaient un choc hypotonique ou l’ajout d’ouabaïne. Des mesures d’ADC ont été effectuées sur des corps neuronaux isolés et sur du tissu de ganglion, avant et après sollicitation. Les deux types de stress ont entraîné une augmentation de l’ADC dans la cellule et une diminution globale de l’ADC dans le tissu. Ces résultats soutiennent l’hypothèse que la diffusion ralentie de l’eau habituellement observée dans un tissu ischémié (ou dans d’autres conditions associées à un gonflement cellulaire) est due à l’augmentation de surface membranaire. / Recent progress in magnetic resonance imaging (MRI) has opened the way for micron-scale resolution, and thus for imaging biological cells. In this thesis work, we performed magnetic resonance microscopy (MRM) on the nervous system of Aplysia californica, a model particularly suited due to its simplicity and to its very large neuronal cell bodies, in the aim of studying cellular-scale processes with various MR contrasts. Experiments were performed on a 17.2 Tesla horizontal magnet, at resolutions down to 25 µm isotropic. Initial work consisted in conceiving and building radiofrequency microcoils adapted to the size of single neurons and ganglia. The first major part of the project consisted in using the manganese ion (Mn2+) as neural tract tracer in the buccal ganglia of Aplysia. Manganese is an MR contrast agent that enters neurons via voltage-gated calcium channels. We performed the mapping of axonal projections from motor neurons into the peripheral nerves of the buccal ganglia. We also confirmed the existence of active Mn2+ transport inside the neural network upon activation with the neurotransmitter dopamine. In the second major part of the project, we tested the potential of two diffusion MRI sequences for microscopy. On the one hand, we explored a very original mechanism for diffusion weighting, DESIRE (Diffusion Enhancement of SIgnal and REsolution), particularly suited for small samples. The two-dimensional DESIRE sequence was implemented and successfully tested on phantoms. The measured enhancement was consistent with theoretical predictions. Using this sequence to produce diffusion weighted images with an unprecedented contrast in biological tissue remains a challenge. On the other hand, a more “standard” sequence was implemented to measure the apparent diffusion coefficient (ADC) in nervous tissue with MRM. This sequence was a three-dimensional DP-FISP (Diffusion Prepared Fast Imaging with Steady-state free Precession), which met criteria for high resolution in a short acquisition time, with minimal artifacts. Using this sequence, we studied the changes in water ADC at different scales in the nervous system, triggered by cellular challenges. The challenges were hypotonic shock or exposure to ouabain. ADC measurements were performed on single isolated neuronal bodies and on ganglia tissue, before and after challenge. Both types of stress produced an ADC increase inside the cell and an ADC decrease at tissue level. The results favor the hypothesis that the increase in membrane surface area associated with cell swelling is responsible for the decrease of water ADC in tissue, typically measured in ischemia or other conditions associated with cell swelling.
264

Quantification du mouvement et de la déformation cardiaques à partir d'IRM marquée tridimensionnelle sur des données acquises par des imageurs Philips / Quantification of cardiac motion and deformation from 3D tagged MRI acquired by Philips imaging devices

Zhou, Yitian 03 July 2017 (has links)
Les maladies cardiovasculaires sont parmi les principales causes de mortalité à l’échelle mondiale. Un certain nombre de maladies cardiaques peuvent être identifiées et localisées par l’analyse du mouvement et de la déformation cardiaques à partir de l’imagerie médicale. Cependant, l’utilisation de ces techniques en routine clinique est freinée par le manque d’outils de quantification efficaces et fiables. Dans cette thèse, nous introduisons un algorithme de quantification appliqué aux images IRM marquées. Nous présentons ensuite un pipeline de simulation qui génère des séquences cardiaques synthétiques (US et IRM). Les principales contributions sont décrites ci-dessous. Tout d’abord, nous avons proposé une nouvelle extension 3D de la méthode de la phase harmonique. Le suivi de flux optique en utilisant la phase a été combiné avec un modèle de régularisation anatomique afin d’estimer les mouvements cardiaques à partir des images IRM marquées. En particulier, des efforts ont été faits pour assurer une estimation précise de la déformation radiale en imposant l’incompressibilité du myocarde. L’algorithme (dénommé HarpAR) a ensuite été évalué sur des volontaires sains et des patients ayant différents niveaux d’ischémie. HarpAR a obtenu la précision de suivi comparable à quatre autres algorithmes de l’état de l’art. Sur les données cliniques, la dispersion des déformations est corrélée avec le degré de fibroses. De plus, les segments ischémiques sont distingués des segments sains en analysant les courbes de déformation. Deuxièmement, nous avons proposé un nouveau pipeline de simulation pour générer des séquences synthétiques US et IRM pour le même patient virtuel. Les séquences réelles, un modèle électromécanique (E/M) et les simulateurs physiques sont combinés dans un cadre unifié pour générer des images synthétiques. Au total, nous avons simulé 18 patients virtuels, chacun avec des séquences synthétiques IRM cine, IRM marquée et US 3D. Les images synthétiques ont été évaluées qualitativement et quantitativement. Elles ont des textures d’images réalistes qui sont similaires aux acquisitions réelles. De plus, nous avons également évalué les propriétés mécaniques des simulations. Les valeurs de la fraction d’éjection et de la déformation locale sont cohérentes avec les valeurs de référence publiées dans la littérature. Enfin, nous avons montré une étude préliminaire de benchmarking en utilisant les images synthétiques. L'algorithme générique gHarpAR a été comparé avec un autre algorithme générique SparseDemons en termes de précision sur le mouvement et la déformation. Les résultats montrent que SparseDemons surclasse gHarpAR en IRM cine et US. En IRM marquée, les deux méthodes ont obtenu des précisions similaires sur le mouvement et deux composants de déformations (circonférentielle et longitudinale). Toutefois, gHarpAR estime la déformation radiale de manière plus précise, grâce à la contrainte d’incompressibilité du myocarde. / Cardiovascular disease is one of the major causes of death worldwide. A number of heart diseases can be diagnosed through the analysis of cardiac images after quantifying shape and function. However, the application of these deformation quantification algorithms in clinical routine is somewhat held back by the lack of a solid validation. In this thesis, we mainly introduce a fast 3D tagged MR quantification algorithm, as well as a novel pipeline for generating synthetic cardiac US and MR image sequences for validation purposes. The main contributions are described below. First, we proposed a novel 3D extension of the well-known harmonic phase tracking method. The point-wise phase-based optical flow tracking was combined with an anatomical regularization model in order to estimate anatomically coherent myocardial motions. In particular, special efforts were made to ensure a reasonable radial strain estimation by enforcing myocardial incompressibility through the divergence theorem. The proposed HarpAR algorithm was evaluated on both healthy volunteers and patients having different levels of ischemia. On volunteer data, the tracking accuracy was found to be as accurate as the best candidates of a recent benchmark. On patient data, strain dispersion was shown to correlate with the extent of transmural fibrosis. Besides, the ischemic segments were distinguished from healthy ones from the strain curves. Second, we proposed a simulation pipeline for generating realistic synthetic cardiac US, cine and tagged MR sequences from the same virtual subject. Template sequences, a state-of-the-art electro-mechanical (E/M) model and physical simulators were combined in a unified framework for generating image data. In total, we simulated 18 virtual patients (3 healthy, 3 dyssynchrony and 12 ischemia), each with synthetic sequences of 3D cine MR, US and tagged MR. The synthetic images were assessed both qualitatively and quantitatively. They showed realistic image textures similar to real acquisitions. Besides, both the ejection fraction and regional strain values are in agreement with reference values published in the literature. Finally, we showed a preliminary benchmarking study using the synthetic database. We performed a comparison between gHarpAR and another tracking algorithm SparseDemons using the virtual patients. The results showed that SparseDemons outperformed gHarpAR in processing cine MR and US images. Regarding tagged MR, both methods obtained similar accuracies on motion and two strain components (circumferential and longitudinal). However, gHarpAR quantified radial strains more accurately, thanks to the myocardial incompressibility constraint. We conclude that motion quantification solutions can be improved by designing them according to the image characteristics of the modality and that a solid evaluation framework can be a key asset in comparing different algorithmic options.
265

Une nouvelle approche de la physiopathologie de la schizophrénie : imagerie des modifications cérébrales biochimiques et fonctionnelles induites par des thérapeutiques non pharmacologiques / Non-pharmacological therapies’ effects on brain biochemistry and functioning : a new approach of schizophrenia physiopathology

Bor, Julie 10 September 2010 (has links)
Malgré le développement de nouvelles générations d’antipsychotiques, certains symptômes schizophréniques ne répondent pas à ces traitements. S’appuyant sur des hypothèses physiopathologiques sous tendant ces symptômes, de nouvelles thérapeutiques comme la thérapie de remédiation cognitive et les techniques de neurostimulation externe ont été développées. Cette approche était restée essentiellement clinique. Dans ce travail, l’étude en imagerie des mécanismes biologiques sous tendant les effets bénéfiques de ces thérapeutiques non pharmacologiques nous a permis de tester des hypothèses physiopathologiques. L’IRM fonctionnelle (IRMf) et la spectroscopie par résonance magnétique (SRM) ont été utilisées pour rechercher les effets d’une thérapie de remédiation cognitive (TRC), de la stimulation magnétique transcrânienne (TMS) et de la stimulation électrique transcrânienne en courant continu (tDCS). Nous avons mis en évidence (1) que la TRC modifie les activations cérébrales durant une tâche de mémoire de travail chez des patients schizophrènes (2) que la TMS modifie la biochimie cérébrale de la zone stimulée et de régions cérébrales profondes chez un patient schizophrène, (3) que la tDCS modifie les réseaux de connectivité fonctionnelle d’une tâche de repos chez des volontaires sains / Despite the development of new generation antipsychotic drugs, some symptoms of schizophrenia do not respond to these treatments. Based on the pathophysiological hypothesis underlying these symptoms, new therapies such as cognitive remediation therapy and neurostimulation techniques have been developed. This approach remained essentially clinical. In this work, the study of biological mechanisms tending benefits of these non-pharmacological treatment has allowed us to test these pathophysiological hypotheses. Functional MRI (fMRI) and magnetic resonance spectroscopy (MRS) were used to investigate the effects of cognitive remediation therapy (CRT), transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS). We demonstrated (1) that CRT modifies cerebral activations during a working memory task in patients with schizophrenia, (2) that TMS modifies brain biochemistry of the stimulated area and of deep brain regions in a patient with schizophrenia and (3) that tDCS modifies the functional connectivity in resting state networks of healthy volunteers
266

Interpolation des données en imagerie cardiaque par résonance magnétique du tenseur de diffusion

Yang, Feng 15 January 2011 (has links) (PDF)
L'un des problèmes fondamentaux de l'imagerie cardiaque par résonance magnétique du tenseur de diffusion (IRM-TD) est sa faible résolution spatiale, à cause des limitations matérielles des scanners IRM actuels. L'objectif principal de ce travail de thèse est de développer de nouvelles approches pour améliorer la résolution des données d'IRM-TD afin de mieux représenter l'architecture myocardique du coeur humain et de la comparer avec des résultats issus d'autres techniques d'investigation telles que l'imagerie par lumière polarisée. Dans ce cadre, le travail porte sur trois parties principales. La première concerne le développement d'une nouvelle approche pour l'interpolation des champs de vecteurs propres principaux issus de l'IRM-TD cardiaque humaine. Cette approche consiste d'abord à supprimer les vecteurs corrompus par le bruit au lieu de débruiter de manière uniforme le champ entier de vecteurs, et ensuite à interpoler le champ de vecteurs en utilisant la modèle Thin-Plate-Spline (TPS) afin d'exploiter la corrélation entre les composantes du vecteur. La deuxième partie concerne une nouvelle famille de méthodes d'interpolation pour les champs de tenseurs, basée soit sur les angles d'Euler soit sur le quaternion. Ces méthodes exploitent les caractéristiques du tenseur et préservent les paramètres de tenseurs, tels que le déterminant du tenseur, l'anisotropie fractionnelle (FA) et la diffusivité moyenne (MD). En outre, cette partie compare les principales approches d'interpolation au niveau des images pondérées en diffusion et des champs de tenseurs, et les résultats montrent qu'il serait préférable d'effectuer l'interpolation des données d'IRM-TD au niveau des champs de tenseurs. La troisième partie étudie le changement des paramètres MD et FA après un infarctus du myocarde chez les cochons, et l'influence des méthodes d'interpolation sur ces paramètres dans la zone infarctus et la zone distante. Les résultats montrent que la zone infarctus présente une diminution significative de FA et une augmentation significative de MD, comparée avec la zone distante, et que les méthodes d'interpolations du tenseur ont plus d'influence sur FA que sur MD, ce qui suggère que l'interprétation de ces paramètres cliniques après l'interpolation doive être prise avec précaution.
267

Imagerie des faisceaux de fibres et des réseaux fonctionnels du cerveau : application à l'étude du syndrome de Gilles de la Tourette

Malherbe, Caroline 28 March 2012 (has links) (PDF)
L'objectif de cette thèse est d'identifier et caractériser les boucles anatomiques et fonctionnelles cortico-sous-corticales chez l'Homme, à partir de données d'imagerie par résonance magnétique fonctionnelle (IRMf) au repos et de diffusion. Une boucle est un ensemble de régions corticales, sous-corticales et cérébelleuses, qui interagissent afin d'effectuer ou de préparer une tâche.Le premier axe de ce travail vise à identifier les réseaux fonctionnels cortico-sous-corticaux en IRMf au repos. Nous proposons une méthode statistique robuste séparant l'analyse corticale de l'analyse sous-corticale. Une analyse en composantes indépendantes spatiales est d'abord réalisée individuellement sur les régions corticales, et suivie d'une classification hiérarchique. Les régions sous-corticales associées sont ensuite extraites par un modèle linéaire général dont les régresseurs comportent la dynamique des régions corticales, suivi d'une analyse de groupe à effets aléatoires. La méthode est validée sur deux jeux de données différents. Un atlas immunohistochimique des structures sous-corticales permet ensuite de déterminer la fonction sensorimotrice, associative ou limbique des réseaux obtenus. Nous montrons enfin que l'anatomie est un support pour la fonction chez des sujets sains.Le dernier axe étudie le syndrome de Gilles de la Tourette, qu'on pense être dû à un dysfonctionnement des boucles cortico-sous-corticales. Nous caractérisons d'abord les boucles cortico-sous-corticales fonctionnelles grâce à des métriques d'intégration et de théorie des graphes, et des différences en termes de connectivité sont mises en évidence entre patients adultes et volontaires sains. Nous montrons également que les boucles cortico-sous-corticales fonctionnelles chez les patients sont soutenues par l'anatomie sous-jacente.
268

Imagerie multimodale et quantitative en TEP/IRM / Multimodal and quantitative imaging in PET/MRI

Monnier, Florian 02 March 2018 (has links)
L’introduction en clinique de la bimodalité combinant la tomographie d’émission de positons (TEP) et la tomodensitométrie (TDM) a été un succès dans les années 2000. La multimodalité dans le contexte de l’imagerie médicale a souvent pour but de combiner une information physiologique à une information anatomique. Deux approches existent : la première étant d’acquérir séparément les modalités et de les combiner ultérieurement par fusion d’images sur ordinateur, la seconde s’affranchit des problèmes possibles du recalage en opérant une acquisition dans le même statif des deux modalités. Cependant, il existe des limites à l’imagerie TEP/TDM. L’idée de combiner l’imagerie par résonance (IRM) magnétique à la TEP offre des avantages par rapport à la TDM. Notamment, l’IRM offre un excellent contraste des tissus et offre l’accès à de l’information multidimensionnelle, fonctionnelle et morphologique grâce à la modularité offerte par l’acquisition IRM. Cette information pourrait permettre de mieux comprendre les processus physiopathologiques des maladies. De plus, l’IRM n’est pas ionisante, au contraire de l’imagerie TDM. L’introduction au début des années 2010 des premiers appareils d’acquisition simultanée TEP/IRM offre de nombreuses possibilités, mais il reste des défis à résoudre avant d’assister à la même diffusion en clinique que l’imagerie TEP/TDM de ces appareils. Notamment, l’atténuation photonique, qui doit être corrigée afin de permettre le caractère quantitatif de l’imagerie, est un problème. Dans ce travail, nous abordons cette question en proposant des solutions pour les différentes régions du corps. Une attention particulière est portée à la région pelvienne. L’état de l’art des méthodes disponibles expose un faible nombre de solutions pour cette région, pourtant riche en tissus osseux atténuants et zone d’occurrence du second cancer le plus commun chez l’homme : le cancer de la prostate. Nous évaluons l’impact de la solution proposée sur la correction des photons diffusés, toujours dans un objectif d’obtenir une imagerie quantitative. Les différentes méthodologies de correction et d’évaluation font intervenir des simulations numériques Monte Carlo. / The clinical introduction of the bimodality combining the positron emission tomography (PET) and the computed tomography (CT) has been a major success in the 2000s. Multimodality, in the context of medical imaging, often has the aim of associating a physiological information and an anatomical information. Two approaches exist : either the two modalities are acquired separately and then fused through computerized image fusion, or we discard the issues related to image registration by acquiring in the same system the two modalities. However, there remain limits to PET/CT imaging. The idea to combinemagnetic resonance imaging (MRI) to PET offers solutions and advantages compared to the use of TDM.MRI offers an excellent tissue contrast and offers an access to multidimensional functional and morphological information thanks to the modularity offered by MRI. This information could improve the understanding of the physiopathological processes involved in diseases. Moreover, MRI is non-ionizing modality, on the contrary to CT. The introduction in the early 2010s of the first simultaneous PET/MRI systems offers a lot of possibilities, but there remains challenged to solve before observing the same spread as the PET/CT in imaging facilities. In particular, the photon attenuation, which must be corrected to provide a quantitative imaging, remains an issue. In this work, we address this issue by proposing solutions for the different regions of the body. A special attention is drawn to the pelvic region. Indeed, the state of the art of available methods exposes a small number of solutions for this area ; even so it is rich in attenuation osseous tissues et area of occurrence of the second most common cancer in men : prostate cancer. We assess the impact of the proposed solution on the scattered photons correction, still in the aim of obtaining a quantitative imaging modality. The different methodologiesof correction and evaluation use Monte Carlo numerical simulations.
269

Evaluation clinique et expérimentale des nouvelles modalités d'imagerie dans la prise en charge des néoplasies ORL notamment par la TEP/IRM / Clinical and experimental evaluation of multiparametric imaging of head and neck carcinomas in particular by TEP / MRI

Varoquaux, Arthur Damien 09 December 2014 (has links)
En oncologie ORL, l'imagerie multiparamétrique est utilisée par un nombre grandissant d'équipes. Parmi les bio-marqueurs, la captation normalisée du fluoro-désoxyglucose (SUV-FDG) en tomoscintigraphie par émission de positons (TEP) et la restriction de la diffusion en IRM (DWI-MRI) sont les plus utilisées.L'IRM couplée à la TEP (TEP/IRM) est une nouveauté qui permet une diminution très significative des doses d'irradiation délivrées par rapport à la TEP/TDM. Nous adressons notre première expérience concernant l'aspect en diffusion et en TEP/IRM dans la surveillance des patients après radio-chimiothérapie. A la question de l'interchangeabilité du FDG-PET et de la DWI-MRI, nous avons tenté d'identifier un lien en imagerie entre la cellularité tumorale et sa consommation glucidique. La cellularité tumorale est approchée en IRM par la mesure du coefficient apparent de diffusion (ADC) et son métabolisme glucidique est approché en TEP en utilisant le 18F-desoxyglucose (FDG) par la mesure de la valeur de fixation normalisée (SUV). Dans une série appariée de 33 patients, nous avons analysé la reproductibilité des mesures de l'ADC et de SUV. Puis nous avons évalué l'indépendance statistique de ces biomarqueurs. Nous avons ensuite voulu comparer les résultats de la TEP obtenus à partir de la TEP/TDM et de la TEP/IRM. Dans une série prospective appariée chez 32 patients explorés en FDG-TEP, nous avons évalué qualitativement les images obtenues par la fusion des images recalées en TEP/IRM et TEP/TDM. Nous avons ensuite comparé la pertinence clinique des deux techniques. Et enfin nous avons comparé les valeurs quantitatives de SUV obtenues du tissu sain et du tissu pathologique. / Multiparametric imaging interest and clinical use is rising for head and neck carcinoma (HNC). Among these modalities, FDG in PET and DWI-MRI are the most studied. PET/MRI is a new modality that allows in a single examination of combined various biologic biomarkers.After an optimization process of PET/MRI, we applied our first experience concerning the aspects of DWI-MRI and PET-MRI after radiation therapy. Thereafter we studied the correlation of SUV and ADC in HNC. In this study SUV and ADC values were independent parameters in HNSCC. Measurements of these two biomarkers were reproducible with almost perfect observer agreements for both methods. Neither SUV nor ADC values were able to predict the histologic grade, although a trend towards higher SUV and lower ADC values was observed in poorly differentiated tumours. Secondly, we we studied detection and quantification of focal uptake in head and neck tumours: 18F-FDG PET/MRI versus PET/CT in 32 consecutive HNSCC who underwent 18F-FDG PET/MRI and PET/CT. Attenuation correction sequence for PET/MRI and CT for PET/CT were used to caculate SUV. In results, PET/MRI coregistration and image fusion was feasible in all patients. There was no statistically significant difference between PET/MRI and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUV measured on PET/MRI and PET/CT. SUV measured on PET/MRI were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p <0.05).
270

Path reconstruction in diffusion tensor magnetic resonance imaging / Reconstitution de la trajectoire dans le diffusion tenseur magnétique résonance imagerie

Song, Xin 13 July 2011 (has links)
L'environnement sous-marin compliqué et la pauvre vision sous-marine font le robot câblé sous-marin super-mini-à peine pour être contrôlés. Traditionnellement, la méthode de contrôle manuelle par les opérateurs est adoptée par cette sorte de robots. Malheureusement, les robots peuvent à peine travailler normalement dans ces circonstances pratiques. Donc, pour surmonter ces manques et améliorer les capacités de ces robots câblés sous-marins, ce papier propose plusieurs améliorations, en incluant le design de système, le design de contrôleur de mouvement, la reconnaissance d'obstacle en trois dimensions et les technologies de reconstruction de sentier en trois dimensions etc. (1) Super-mini sous-marins de conception système de robot: plusieurs programmes d'amélioration et d'idées de conception importants sont étudiés pour la super-mini robot sous-marin (2) La conception du contrôleur de mouvement du robot sous-marin dans des circonstances compliquées est étudiée. Un nouveau réseau de neurones adaptatif coulissantes contrôleur de mode avec le contrôleur paramètre équilibrée est proposé. Basé sur la théorie de la gestion adaptative floue contrôleur de mode coulissant , un algorithme amélioré est également proposé et appliqué à l'robot sous-marin. (3) Recherche de reconstructions d'environnement sous-marines en trois dimensions : les algorithmes et les expériences de reconstructions d'environnement sous-marines sont enquêtés. L'algorithme de traitement d'image de DT-MRI et la théorie de reconstructions d'obstacle en trois dimensions sont adoptés et améliorés pour l'application du robot sous-marin. / The complicated underwater environment and the poor underwater vision make super-mini underwater cable robot hardly to be controlled. Traditionally, the manual control method by operators is adopted by this kind of robots. Unfortunately, the robots can hardly work normally in these practical circumstances. Therefore, to overcome these shortcomings and improve the abilities of these underwater cable robots, this paper proposes several improvements, including the system design, the motion controller design, three dimensional obstacle recognition and three dimensional path reconstruction technologies etc. The details are displayed as follow: (1) Super-mini underwater robot system design: several improvement schemes and important design ideas are investigated for the super-mini underwater robot.(2) Super-mini robot motion controller design: The motion controller design of underwater robot in complicated circumstance is investigated. A new adaptive neural network sliding mode controller with balanced parameter controller (ANNSMB) is proposed. Based on the theory of adaptive fuzzy sliding mode controller (AFSMC), an improved algorithm is also proposed and applied to the underwater robot. (3)Research of three dimensional underwater environment reconstructions: The algorithms and the experiments of underwater environment reconstructions are investigated. DT-MRI image processing algorithm and the theory of three dimensional obstacle reconstructions are adopted and improved for the application of the underwater robot. (4) The super-mini underwater robot path planning algorithms are investigated.

Page generated in 0.029 seconds