• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 32
  • 32
  • 23
  • 19
  • 16
  • 16
  • 13
  • 13
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da alteração linear de fundições com liga de níquel-cromo, obtidas por meio de dois revestimentos fosfatados de diferentes composições /

Goshi, Carlos Magno. January 2000 (has links)
Orientador: Fernando Eidi Takahashi / Banca: Sebastião Simões Gomes / Banca: Sigmar de Mello Rode / Resumo: Este trabalho avaliou a alteração linear de fundições com liga de níquel-cromo (Verabond II) obtidas com dois revestimentos fosfatados, sendo um com carga refratária à base de cerâmica granulada (Microfine 1700) que permite a introdução do anel após a presa diretamente em um forno pré-aquecido (750°C) e outro à base de cristobalita (Bellavest-T) de procedimento convencional. Quarenta padrões de cera (Bredent life-color-wachs) foram obtidos por meio de moldagem direta de uma matriz de aço inoxidável. Vinte padrões de cera foram incluídos com Microfine 1700 e vinte com Bellavest-T. Com o auxílio de um projetor de perfil com precisão de 0,001mm, mediu-se a distância entre dois pontos pré-estabelecidos na matriz. A mesma distância foi medida posteriormente na peça metálica reproduzida em liga de níquel-cromo, obtendo-se assim, as medidas das possíveis alterações dimensionais. Os resultados evidenciaram que a média da alteração linear das fundições com os dois revestimentos em relação à matriz, através do Test T de Student foi significante estatisticamente em nível de 5% para o Bellavest-T e em nível de 1% para o Microfine 1700. As conclusões foram as seguintes: a) os dois revestimentos não conseguiram compensar a contração da liga metálica e da cera no processo de fundição; b) a média das distâncias das fundições obtidas com revestimento Microfine 1700, apesar de apresentarem-se menores que a matriz e as fundições com o revestimento Bellavest-T, revelaram medidas mais constantes / Abstract: This study evatuated the linear alteration of castings with NiCr alloy (Verabond II) obtained with two phosphate-bonded investments, one with granuled ceramic refractory load (Microfine 1700), which allows the introduction of the ring after setting directly in a pre-heated oven (750ºC); and another one, cristobalite-based (Bellavest-T) for conventional procedure. Forty wax patterns (Bredent life - color wachs, regular type II) were obtained through the direct molding of a stainless steel plate. Twenty wax patterns were invested in Microfine 1700 and twenty in Bellavest-T. A profile projector (0.001mm precision) measured the distance between 2 pre-established points in the matrix. The same distance was measured on the wax patterns and on the NiCr specimens produced, hereby obtaining the measure of the possible dimensional alterations of the materials. The results showed significance between the 2 investments (Bellavest-T, 5% and Microfine 1700, 1%) as compared to the matrix, through the Student's t test. The conclusions were: a) the two investments could not compensate the contraction of the alloy and wax in the casting process; b) the mean distance of the castings obtained with Microfine 1700, despite the fact of being smaller than the matrix and than the castings of Bellavest-T, showed more constant dimensions / Mestre
12

Estudo comparativo in vivo da osseointegração em duas diferentes superfícies de implantes em liga TiAlV. Caracterização topográfica, análise de frequência por ressonância e histométrica /

Colombo, Luara Teixeira. January 2019 (has links)
Orientador: Francisley Ávila Souza / Banca: Idelmo Rabgel Garcia Junior / Banca: Osny Ferreira Júnior / Resumo: Objetivo: Avaliar o comportamento biológico do tecido ósseo ao redor de implantes manufaturados em liga Ti6Al-4V diante das superfícies modificadas por jateamento de óxido de alumínio seguido condicionamento ácido (SBAS) e a superfície usinada (MS). Material e Métodos: Dez coelhos receberam aleatoriamente 20 implantes de hexágono externo com dimensões de 4,0 mm de diâmetro e 10 mm de comprimento em suas tíbias direita e esquerda, sendo um implante de cada superfície em cada tíbia. Os implantes de ambos os grupos foram analisados através de microscopia eletrônica de varredura (MEV-EDX) e microscopia de força atômica (AFM). Discos com as mesmas superfícies foram submetidos à análise de rugosidade média (Ra) e secção transversal. Nos períodos de 3 e 6 semanas foi mensurado o coeficiente de estabilidade primária por meio da análise de frequência por ressonância (ISQ), seguido da eutanásia dos animais. As peças obtidas foram submetidas ao processamento de inclusão em resina fotopolimerizável e levadas ao micrótomo para corte calcificado. Foi mensurada em porcentagem a extensão linear de contato entre tecido ósseo mineralizado e implante (ELCOMI) e área óssea neoformada (AON). Os dados foram submetidos à análise de variância e ao teste t de Tukey. Resultados: MEV e AFM mostraram diferenças na topografia das superfícies. Os valores médios obtidos pelas análises de frequência por ressonância, Ra e secção transversal para SBAS foram estatisticamente superiores (p<0,05) quando comparad... (Resumo completo, clicar acesso eletrônico abaixo) / Objective: Evaluate the biological behavior of bone tissue around implants manufactured in Ti-6Al-4V alloy before surfaces modified by aluminum oxide blasting followed by acid etching (SBAS) and machined surface (MS).Material and Methods: Ten rabbits randomly received 20 external hexagon implants with dimensions of 4.0 mm in diameter and 10 mm in length on theirright and left tibiae, one implant of each surface on each tibia. The implants of both groups were analyzed by scanning electron microscopy (SEM-EDX) and atomic force microscopy (AFM). Disks withthe same surfaces were submitted to analysis of average roughness (Ra) and cross section. In the periods of 3 and 6 weeks, the primary stability coefficient was measured by means of resonance frequency analysis (ISQ), followed by euthanasia of the animals. The obtained pieces were submitted to the inclusion processing in photopolymerizable resin and taken to the microtome for cutting without decalcification. The bone interface contact (BIC) and neoformed bone area (NBA) was measured in percentage. Data were submitted to analysis of variance and Tukey t test. Results: SEM and AFM showed differences in surface topography. The mean values obtained by the resonance, Ra and cross sectionanalyzes for SBAS were statistically higher (p <0.05) when compared to MS. The mean values in percentage of BICfor SBAS were 69.65 and 71.56 respectively for 3 and 6 weeks, while for MS the mean values were 54.06and 55.99 respectively for the same periods. The mean values of NBAin the SBAS group were 69.86 and 79.59 for the 3 and 6 week periods, while forMS the mean values were 59.59and 74.32, respectively, in the same groups. There were statistically superior differences (p <0.05) in SBAS implants for BICin the 3 and 6 week periods and AON in the 3 week period. Conclusion: The surface modification of the SBAS implants providedchanges... (Complete abstract electronic access below) / Mestre
13

Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes /

Silva, Eduardo Galera da. January 1997 (has links)
Orientador: João Vieira de Moraes / Banca: Celso -Ite Tanaka / Banca: Maria Amélia Maximo de Araújo / Resumo: O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica / Abstract: This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements / Mestre
14

Desenvolvimento e caracterização de ligas de Co-Cr-Mo / Development and characterization of Co-Cr-Mo alloy

Martinelli, Carolina da Silva Machado [UNESP] 05 February 2016 (has links)
Submitted by CAROLINA DA SILVA MACHADO MARTINELLI null (carolinasmm@yahoo.com.br) on 2016-04-01T13:23:06Z No. of bitstreams: 1 Martinelli CSM.pdf: 41556669 bytes, checksum: 11b357cf7cd8daadc269baa8ee512828 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-04-05T14:21:09Z (GMT) No. of bitstreams: 1 martinelli_csm_dr_sjc.pdf: 41556669 bytes, checksum: 11b357cf7cd8daadc269baa8ee512828 (MD5) / Made available in DSpace on 2016-04-05T14:21:09Z (GMT). No. of bitstreams: 1 martinelli_csm_dr_sjc.pdf: 41556669 bytes, checksum: 11b357cf7cd8daadc269baa8ee512828 (MD5) Previous issue date: 2016-02-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As ligas de Co-Cr têm o uso consagrado para reabilitação oral com próteses dentárias. Os procedimentos reabilitadores orais por implantes osseointegrados destacaram novas necessidades biomecânicas e estruturais das ligas metálicas. O objetivo deste estudo foi desenvolver e caracterizar três ligas metálicas de Co-Cr-Mo experimentais, para aplicação odontológica. Foram confeccionadas ligas de Co-Cr-Mo, com percentuais crescentes de Mo (6, 7 e 8% - A, B e C, respectivamente), por duas técnicas de processamento: L2, fusão para acréscimo de Mo a uma liga comercial certificada (American Society for Testing and Materials, 1996) (L1); e L3, fusão dos metais Co, Cr e Mo, comercialmente puros. As ligas em estudo foram caracterizadas microestruturalmente por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios X (DRX), fluorescência de raios X (XDR); fisicamente por microdureza, resistência à corrosão. Fibroblastos dérmicos humanos foram utilizados para avaliar a citotoxicidade das ligas experimentais após 1, 4 e 7 dias de cultura celular. Organização citoesquelética, adesão, viabilidade, morfologia e diferenciação celular foram avaliados por microscopia de fluorescência, análise bioquímica e MEV. Os resultados obtidos permitiram concluir que as ligas experimentais (L2A, L2B, L2C, L3A, L3B e L3C) apresentaram desempenho microsestrutural, mecânico e citotóxico superior à L1, sendo indicada para utilização biomédica e odontológica. / In Dentistry, the Co-Cr alloys are general used for oral rehabilitation by dental prosthesis. The oral rehabilitation procedures by osseointegrated implants point out to new metal alloys’ biomechanical and structural necessities. The aim of this study was develop and characterize three experimental Co-Cr-Mo alloys, for dental application. Three alloys will be made out with different Mo’s percentages by two processing techniques: L2, casting by addition of Mo to a certified commercial Co-Cr alloy (American Society for Testing and Materials, 1996) (L1); and L3, casting of purified commercial metals (Co, Cr, Mo). The experimental alloys were characterized by microstructure by digital optical microscopy, scanning electron microscopy, energy dispersive X-ray spectrometry, X-ray diffraction and X-ray fluorescence; and mechanically by microhardness and corrosion resistance. Human dermal fibroblasts were used to evaluate the biocompatibility of experimental Co-Cr alloys after 1, 4 and 7 days of culture. Cellular adhesion, proliferation, viability, cytoskeletal organization and morphology were investigated using fluorescence microscope, biochemical assay and SEM. Based on data was possible to concluded that experimental alloys (L2A, L2B, L2C, L3A, L3B e L3C) shown higher performance for microstructure, mechanical and cytotoxic as L1 and they are recommend to biomedical and dentistry applications. / FAPESP: 2013/12437-4 / CAPES: 99999.004105/2014-01
15

Avaliação da alteração linear de fundições com liga de níquel-cromo, obtidas por meio de dois revestimentos fosfatados de diferentes composições

Goshi, Carlos Magno [UNESP] 06 July 2000 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-07-06. Added 1 bitstream(s) on 2018-07-27T18:29:52Z : No. of bitstreams: 1 000126006.pdf: 1396022 bytes, checksum: 696526f54981b91d3365782e5f5af3bc (MD5) / Este trabalho avaliou a alteração linear de fundições com liga de níquel-cromo (Verabond II) obtidas com dois revestimentos fosfatados, sendo um com carga refratária à base de cerâmica granulada (Microfine 1700) que permite a introdução do anel após a presa diretamente em um forno pré-aquecido (750°C) e outro à base de cristobalita (Bellavest-T) de procedimento convencional. Quarenta padrões de cera (Bredent life-color-wachs) foram obtidos por meio de moldagem direta de uma matriz de aço inoxidável. Vinte padrões de cera foram incluídos com Microfine 1700 e vinte com Bellavest-T. Com o auxílio de um projetor de perfil com precisão de 0,001mm, mediu-se a distância entre dois pontos pré-estabelecidos na matriz. A mesma distância foi medida posteriormente na peça metálica reproduzida em liga de níquel-cromo, obtendo-se assim, as medidas das possíveis alterações dimensionais. Os resultados evidenciaram que a média da alteração linear das fundições com os dois revestimentos em relação à matriz, através do Test T de Student foi significante estatisticamente em nível de 5% para o Bellavest-T e em nível de 1% para o Microfine 1700. As conclusões foram as seguintes: a) os dois revestimentos não conseguiram compensar a contração da liga metálica e da cera no processo de fundição; b) a média das distâncias das fundições obtidas com revestimento Microfine 1700, apesar de apresentarem-se menores que a matriz e as fundições com o revestimento Bellavest-T, revelaram medidas mais constantes / This study evatuated the linear alteration of castings with NiCr alloy (Verabond II) obtained with two phosphate-bonded investments, one with granuled ceramic refractory load (Microfine 1700), which allows the introduction of the ring after setting directly in a pre-heated oven (750ºC); and another one, cristobalite-based (Bellavest-T) for conventional procedure. Forty wax patterns (Bredent life - color wachs, regular type II) were obtained through the direct molding of a stainless steel plate. Twenty wax patterns were invested in Microfine 1700 and twenty in Bellavest-T. A profile projector (0.001mm precision) measured the distance between 2 pre-established points in the matrix. The same distance was measured on the wax patterns and on the NiCr specimens produced, hereby obtaining the measure of the possible dimensional alterations of the materials. The results showed significance between the 2 investments (Bellavest-T, 5% and Microfine 1700, 1%) as compared to the matrix, through the Student's t test. The conclusions were: a) the two investments could not compensate the contraction of the alloy and wax in the casting process; b) the mean distance of the castings obtained with Microfine 1700, despite the fact of being smaller than the matrix and than the castings of Bellavest-T, showed more constant dimensions
16

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)

Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1 000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)
17

Determinação da resistência à flexão de ligas odontológicas, utilizadas em prótese parcial fixa e prótese sobre implante, soldadas por brasagem e a laser /

Dinato, José Cícero. January 1999 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Afonso Burmann / Banca: Maximiliano Píero Neisser / Resumo: O objetivo deste trabalho foi determinar a resistência à flexão de sessenta corpos-de-prova cilíndricos, obtidos a partir de quatro ligas metálicas utilizadas em prótese parcial fixa e prótese sobre implante, disponíveis no mercado brasileiro (Co-span 13.5, Stabilor G, Deva 4 e Palliag M) medindo 25 mm de comprimento e 3 mm de diâmetro. Cinco corpos-de-prova de cada liga foram fundidos em monobloco, cinco soldados por brasagem e cinco a laser Nd-YAG, Dessa forma, obtiveram-se 15 corpos-de-prova para cada liga metálica, divididos em três grupos. No grupo I, os corpos-de-prova foram fundidos em monobloco; no grupo 2, soldados por brasagem; no grupo 3, soldados a laser. Após a conclusão dos corpos-de-prova, os três grupos foram submetidos a um ensaio de resistência flexural, em uma máquina de testes lnstron. O ensaio consistiu em submeter os corpos-de-prova a uma carga ao seu centro, com as suas extremidades apoiadas em dois cilindros separados por uma distância de 20 mm, de modo que sofressem a ação e reação da carga em apenas três pontos. A velocidade de aplicação da carga foi de 0,5 mm/min, com uma célula de carga de 500 kg. Os resultados numéricos obtidos foram submetidos à Análise de Variância e ao teste de Tukey, ao nível de 5% de probabilidade. Em vista dos resultados obtidos, conclui-se que o maior valor numérico da resistência flexural foi encontrado para a liga Co-span 13.5, seguido do Deva 4, para os grupos de soldagem a laser e monobloco. O material Palliag M apresentou valores estatisticamente semelhantes para os três grupos. A liga Stabilor G apresentou os melhores resultados no método por brasagem / Abstract: The mechanic properties of brazed joints compared with castings performed in monoblocks have been exhaustingly evaluated. The use of laser in Dentistry opened a new and promising field to study this type of fusion. The purpose of this study was to determine the flexural resistance of four types of metal alloys used in fixed partial prosthodontics (Co-span 13.5, Stabilor G, Deva 4 and Palliag M). Fifteen test specimens with 3 mm diameter and 25mm length were obtained by casting for each alloy, and divided in three groups (monoblocks, brazing and laser welding), totaling sixty cylindrical specimens. The specimens were submitted to GLP/O2 torch welding and Nd-YAG laser welding performed with a specific laser equipment (Laser 2002, Dentaurum, Germany). The results were compared with tests performed in monoblocks of these same materials. To determine the flexural resistance, an universal testing machine (Instrom, model 4301), with a 500 Kg maximum capacity was used. The results were statistically analyzed using an ANOVA and Tuckey'.s test in a 5% degree of probability. The results showed that the highest numeric value of flexural resistance was found with the Co-Span alloy, followed by Deva 4, for both laser welding and monoblock groups. Palliag M showed statistically similar values for the laser welding, brazing and monoblock groups, whereas Stabilor G presented its highest values in brazing / Mestre
18

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes : fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem) /

Costa, Elza Maria Valadares da. January 2001 (has links)
Orientador: Maximiliano Piero Neisser / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Marco Antonio Bottino / Resumo : Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Abstract: Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with "chromium steel", five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.) / Mestre
19

Processos de corrosão eletroquímica na liga metálica quaternária Ti-35Nb-7Zr-5Ta a ser utilizada na Implantodontia. /

Italiano, Ana Elisa Vilicev. January 2020 (has links)
Orientador: Luis Geraldo Vaz / Resumo: O sucesso dos implantes dentários em longo período depende da interação do biomaterial com o ambiente bucal, a qual envolve reações eletroquímicas, resistência mecânica (tração, compressão, fadiga) e desgaste mecânico. A fim de aperfeiçoar as propriedades do titânio (Ti), elementos de liga são adicionados, sendo a liga Ti6Al4V a mais comum. Sabe-se que o vanádio e o alumínio são considerados tóxicos. Isto demonstra a importância do desenvolvimento de novas ligas de Ti ultra resistentes e biocompatíveis, a partir do sistema TiNbZr. O objetivo deste trabalho é caracterizar as interações físico-químicas que envolvem as modificações de superfícies da liga metálica quaternária Ti-35Nb-7Zr-5Ta irradiada com feixe de laser, que favorece a incorporação de substâncias químicas que estão presentes na parte inorgânica do osso e que promove a osseointegração. Para a realização deste estudo, os elementos da liga quaternária Ti-35Nb-7Zr-5Ta foram fundidos em forno a arco voltaico com atmosfera inerte, controlada por bomba de vácuo e fluxo de argônio. Em seguida os lingotes obtidos foram usinados e cortados nas medidas 8 mm de diâmetro x 2 mm de espessura. Todo o estudo foi realizado com um número de 15 amostras, que foram divididas em três grupos: Grupo I (sem tratamento), Grupo II (laser 20 Hz) e Grupo III (laser 35 Hz). A modificação de superfície consistiu na irradiação por feixe de laser Yb:YVO4. As análises consistiram na caracterização química metalúrgica e os processos de corrosão e... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
20

Estudo da correlação entre adaptação marginal e tensões transmitidas aos implantes por estruturas metálicas fundidas em monobloco - análise fotoelástica. / A study of the correlation between marginal fit and tensions transmitted to implants by one-piece metal castings - a photoelastic analysis.

Torres, Érica Miranda de 19 December 2005 (has links)
Um dos maiores obstáculos para o sucesso das reabilitações com próteses sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que a ausência de perfeito ajuste e assentamento passivo pode provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Quando estruturas metálicas para próteses sobre múltiplos implantes são fundidas em monobloco, a obtenção de boa adaptação marginal parece ser ainda mais crítica. Contudo, não se verificam estudos que abordem a influência do tipo de metal ou liga empregado nessas fundições sobre os níveis de desadaptação protética. Assim, o presente estudo tem como objetivos verificar a adaptação marginal entre os pilares intermediários e estruturas fundidas em monobloco com diferentes materiais; avaliar, pelo método fotoelástico, as tensões impostas aos implantes quando a eles são fixadas as estruturas metálicas; e ainda pesquisar possíveis correlações entre os níveis de adaptação marginal e as tensões geradas na interface implante-material fotoelástico. Para tanto, utilizando cilindros calcináveis, foram enceradas 15 estruturas para próteses implanto-retidas sobre modelo simulando o posicionamento de cinco implantes na região intermentoniana. As estruturas foram divididas em grupos de cinco e fundidas em monobloco com titânio comercialmente puro grau I, liga de cobalto-cromo ou liga de níquel-cromo-titânio. A adaptação marginal foi avaliada, em microscópio ótico, quanto à passividade, por meio do teste de único parafuso, com aperto alternado nos implantes distais A e E, e quanto aos níveis de desajuste vertical, com todos os parafusos apertados com um torque de 10Ncm. As tensões geradas na área correspondente à região de crista óssea marginal em torno dos implantes foram avaliadas por meio de análise fotoelástica quantitativa empregando o método de compensação de Tardy. Após análise estatística dos resultados (p<0.05), verificou-se que, nos testes de passividade, o Ti cp apresentou resultados significantemente superiores de adaptação quando comparado as ligas de Co-Cr e Ni-Cr-Ti, as quais não apresentaram diferenças estatísticas entre si. O Ti cp foi semelhante à liga de Ni-Cr-Ti quanto aos níveis de desajuste vertical e tensões impostas aos implantes, com resultados superiores àqueles obtidos com a liga de Co-Cr. Foram aplicados testes de correlação entre as tensões fotoelásticas e os seguintes parâmetros: desajuste vertical, passividade média, adaptação marginal absoluta e percentual de redução de desajuste. Verificou-se correlação significante apenas entre os valores de adaptação marginal absoluta e tensões geradas pelas estruturas de Ni-Cr-Ti. Pode-se concluir que estruturas para próteses fixas sobre múltiplos implantes fundidas em monobloco podem produzir níveis biologicamente aceitáveis de desajuste, sendo os melhores resultados obtidos com o Ti cp, seguido das ligas de Ni-Cr-Ti e Co-Cr, respectivamente. Dentre os metais avaliados, a liga de Co-Cr transmitiu maiores níveis de tensões aos implantes. De um modo geral, não foram verificadas correlações entre valores de adaptação marginal e tensões impostas aos implantes. / Obtaining a good marginal fit of the prosthetic components is one of the main obstacles to the success of rehabilitation with implant-supported prostheses. It is not clear, in the literature, which misfit levels are considered clinically acceptable, but it is known that the absence of a perfect and passive fit may cause inadequate tensions on the osseointegration interface, which may bring about mechanical and biological problems. Photoelasticity is an experimental technique, used to analyze tensions, which is capable of producing results that are reliable to clinical parameters. When metal multiple-unit implant frames are cast in a single unit, it seems that obtaining a good marginal fit is even more critical. However, there are no studies in the literature about the influence that the type of metal or alloy used in these castings may have on the levels of prosthesis misfit. Thus, the present study has the aim to verify the marginal fit between the intermediate abutments and the one-piece structures cast with different materials; perform a photoelastic assessment of the tensions caused on implants when metal frames are fixed to them; and, research the possible correlations between the levels of marginal fit and the tensions generated on the interface implant-photoelastic material. To do this, 15 frames for implant-retained prostheses were waxed, using calcinable cylinders, simulating the positioning of five implants on the inter-mentalis region. The frames were divided into groups (n=5) and cast in a single piece with commercially pure titanium grade I, cobalt-chrome alloy, or nickel-chrome-titanium alloy. Marginal fit was assessed by optic microscopy, in terms of passivity, by a single screw test with alternate tightening on the distal implants A and E. As to the levels of vertical misfit, all screws were tightened to a torque of 10Ncm. Tensions generated in the area corresponding to the marginal bone crest region surrounding the implants were assessed by quantitative photoelastic analysis using the Tardy compensation method. After the statistical analysis of the results (p<0.05), it was verified that, in the passivity tests, the Ti cp showed significantly superior fitting results when compared to the Co-Cr and Ni-Cr-Ti alloys, which showed no statistically significant differences between them. In terms of the levels of vertical misfit and tensions over the implants, Ti cp was similar to the Ni-Cr-Ti alloy, showing superior results when compared to the Co-Cr alloy. Correlation tests were performed between the photoelastic tensions and the following parameters: vertical misfit, mean passivity, absolute marginal fit, and percentage of misfit reduction. A significant correlation was observed only between the values of absolute marginal fit and the tensions generated by the Ni-Cr-Ti frames. It is concluded that one-piece cast multiple-unit implant frames may produce biologically acceptable misfit levels, and the best results are obtained with Ti cp, followed by the Ni-Cr-Ti and Co-Cr alloys, respectively. Among the assessed metals, the Co-Cr alloy transmitted higher tension levels to the implants. In a general way, no correlations were observed between the values of marginal fit and tensions on implants.

Page generated in 0.0803 seconds