• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 15
  • 3
  • 1
  • 1
  • Tagged with
  • 48
  • 48
  • 40
  • 40
  • 31
  • 31
  • 27
  • 27
  • 26
  • 21
  • 12
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeitos do treinamento físico em piscina aquecida em pacientes com hipertensão arterial resistente / Effects of physical training in a heated pool in patients with resistant hypertension

Lais Galvani de Barros Cruz 26 June 2017 (has links)
INTRODUÇÃO: O treinamento físico é uma intervenção eficaz para reduzir a pressão arterial (PA) na hipertensão, mas ainda há pouca evidência na literatura sobre os efeitos do treinamento físico em piscina aquecida. Este estudo examina os efeitos do treinamento em piscina aquecida sobre a PA, bem como sobre as respostas neuro-humorais e endoteliais em pacientes hipertensos resistentes. MÉTODOS: Trata-se de um estudo paralelo, randomizado e controlado. Foram investigados 44 pacientes sedentários com hipertensão resistente, randomizados e alocados em dois grupos; 28 pacientes foram submetidos à um protocolo de treinamento, que consistiu de exercícios calistênicos e caminhada dentro de uma piscina aquecida (32°C), realizados por uma hora, três vezes por semana durante doze semanas; e 16 pacientes foram alocados no grupo controle, esses foram orientados a manter suas atividades habituais. As medições feitas antes e após doze semanas do protocolo incluíram: PA de consultório, monitorização ambulatorial da pressão arterial (MAPA), níveis plasmáticos de óxido nítrico, endotelina-1, aldosterona, renina, noradrenalina, adrenalina e dopamina, assim como VO2 pico e função endotelial (hiperemia reativa). RESULTADOS: Após doze semanas, os pacientes do grupo treinamento apresentaram diminuição significativa na PA de consultório (Sistólica de 164,2 ± 3,3 para 128,9 ± 1,9 mmHg e Diastólica de 89,3 ± 1,7 para 78,0 ± 1,6 mmHg (P < 0,01) e na MAPA de 24 horas (Sistólica de 144,8 ± 3,8 para 126,4 ± 2,3 mmHg, Diastólica de 83,8 ± 2,1 para 74,8 ± 1,6 mmHg (P < 0,01), Vigília (Sistólica de 149,0 ± 4,0 para 129,0 ± 2,4 mmHg, Diastólica de 86,9 ± 2,2 para 75,6 ± 1,7 mmHg (P < 0,01); Sono (Sistólica de 136,1 ± 3,6 mmHg para 115,9 ± 1,8 mmHg, Diastólica de 75,9 ± 2,0 para 70,1 ± 1,6 mmHg (P < 0,01). Concomitantemente, o óxido nítrico aumentou significativamente (de 25±2,8 para 75±2,4 ?mol/L (P < 0,01), enquanto a endotelina-1 (de 41 ± 5 para 26 ± 3 pg / mL), a renina (de 35 ± 4 para 3,4 ± 1 ng / mL / h) , a noradrenalina (de 720 ± 54 para 306 ± 35pg / mL), a adrenalina (353,1 ± 4,1 para 169± 2,2 ng/mL) e dopamina ( de 145,1 ± 2,2 para 36,3 ± 3,1 ng/mL) diminuíram significativamente (P < 0,01). A aldosterona plasmática também tendeu a diminuir, embora não significativamente (de 101 ± 9 para 76 ± 4 pg / mL, P = NS). O VO2 pico aumentou, significativamente, após o treinamento (P < 0,01), enquanto a função endotelial permaneceu inalterada, e não foram encontradas alterações significativas no grupo controle. CONCLUSÕES: O treinamento em piscina aquecida reduziu os níveis de PA tanto ambulatorial quanto durante a MAPA de 24 horas em pacientes hipertensos resistentes e esta resposta da PA foi acompanhada por uma redução significativa da acentuada ativação neurohumoral, que caracteriza essa condição clínica. Estes efeitos sugerem que o treinamento em piscina aquecida pode ser uma potencial nova abordagem terapêutica para estes pacientes / BACKGROUND: Regular exercise is an effective intervention to decrease blood pressure (BP) in hypertension, but no data is available concerning the effects of Heated water-based Exercise (HEx). This study examines the effects of HEx on BP as well as on the neurohumoral and endothelial responses in resistant hypertensive patients. METHODS: This is a parallel, randomized controlled trial. We investigated 44 sedentary patients with resistant hypertension, they were randomized and allocated into 2 groups; 28 patients to a HEx training protocol, which was consisted of callisthenic exercises and walking inside a heated pool (32°C), performed for 1 hour, three times a week for 12 weeks; and 16 patients who were allocated on the control group were asked to maintain their habitual activities. The measurements made before and after 12 weeks of the protocol included clinic BP, ambulatory blood pressure monitoring (ABPM), plasma levels of nitric oxide, endothelin-1, aldosterone, renin, norepinephrine, epinephrine and dopamine, as well as peak VO2, and endothelial function (reactive hyperemia). RESULTS: After 12 weeks of HEx, patients showed a significant decrease in clinic BP (SBP from 164.2 ± 3.3 to 128.9 ± 1.9 mmHg; and DBP from 89.3 ± 1.7 to 78.0 ± 1.6 mmHg (P < 0.01); and on 24-h ABPM (24-h (SBP from 144.8 ± 3.8 to 126.4 ± 2.3 mmHg, DBP from 83.8 ± 2.1 to 74.8± 1.6 mmHg (P < 0.01); Daytime (SBP from 149.0 ± 4.0 to 129.0± 2.4 mmHg, DBP from 86.9 ± 2.2 to 75.6 ± 1.7 mmHg (P < 0.01); Nightime (SBP from 136.1± 3.6 mmHg to 115.9 ± 1.8 mmHg, DBP from 75.9 ± 2.0 to 70.1 ± 1.6 mmHg (P < 0.01). Concomitantly, nitric oxide increased significantly (from 25±2,8 to 75±2,4 ?mol/L, P < 0.01), while endothelin-1 (from 41±5 to 26±3 pg/mL), renin (from 35±4 to 3.4±1 ng/mL/h), norepinephrine (from 720±54 to 306±35pg/mL), epinephrine ( from 353,1 ± 4,1 to 169 ± 2,2 ng/mL) and dopamine (from 145,1 ± 2,2 to 36,3 ± 3.1 ng/mL decreased significantly (P < 0.01). Plasma aldosterone also tended to decrease, although not significantly (from 101±9 to 76±4 pg/mL, P=NS). Peak VO2 increased significantly after HEx (P < 0.01), while endothelial function was unchanged. No significant change was detected in the control group. CONCLUSIONS: HEx reduced office BPs and 24-hour ABPM levels in resistant hypertensive patients and this BP response was accompanied by a significant reduction in the marked neurohumoral activation characterized in this clinical condition. These effects suggest that HEx may be a potential new therapeutic approach in these patients
42

Avaliação objetiva dos hábitos e barreiras da atividade física de portadores de doença pulmonar obstrutiva crônica / Objective assessment of barriers and habits of physical activity in patients with chronic obstructive pulmonary disease

Amorim, Priscila Batista de Souza 10 July 2014 (has links)
INTRODUÇÃO: Pacientes com doença pulmonar obstrutiva crônica (DPOC) tem atividade física reduzida. Barreiras que limitam a atividade física e a medida objetiva da limitação ainda são pouco estudadas nesta população. Conhece-las permite um planejamento adequado para incremento da atividade de vida diária (AVD). OBJETIVO: Comparar a AVD de portadores de DPOC e controles com um sensor de movimento, identificar barreiras que impedem a AVD e correlaciona-los à gravidade da dispneia, ao teste de caminhada de 6 minutos (TC6) e um escore de limitação da AVD. MÉTODOS: O número de passos, a distância percorrida em quilômetros e o tempo de caminhada foram registrados por um acelerômetro de bolso e um pedômetro durante 7 dias consecutivos. Um questionário de barreiras percebidas e a escala AVD (LCADL) foram utilizados para qualificar fatores que impedem a AVD. A dispneia foi medida por duas escalas distintas e a capacidade física submáxima pelo TC6. RESULTADOS: Foram avaliados 40 sujeitos com DPOC e 40 controles saudáveis. Os pacientes com DPOC realizaram tempo menor de caminhada (68,5 ± 25,8 minutos/dia vs. 105,2 ± 49,4; p < 0,001), menor distância (3,9 ± 1,9 km/dia vs. 6,4 ± 3,2; p < 0,001) e menor número de passos/dia. A falta de estrutura, influência social e falta de vontade foram as principais barreiras referidas para realização de AVD. O TC6 correlacionou-se com os resultados do acelerômetro, mas o LCADL não. CONCLUSÃO: Portadores de DPOC são menos ativos quando comparados a adultos saudáveis. Sedentarismo e as barreiras para atividade física tem implicação imediata na prática clínica indicando medidas de intervenção precoce / INTRODUCTION: Patients with chronic obstructive pulmonary disease (COPD) have reduced physical activity. Barriers that limit physical activity and objective measures of limitation are poorly studied in this population. The knowledge of them allows a proper planning for increased physical activity. OBJECTIVES: To compare ADLs in COPD patients and controls using a motion sensor, identify perceived barriers that prevent AVD and correlate them to the severity of dyspnea, to the 6-minute walk test (6MWT) and a score of AVD limitation. METHODS: An pocket accelerometer and a pedometer recorded the number of steps, distance in Km and walking time for seven consecutive days. A survey of perceived barriers and the ADL scale (LCADL) were used to describe factors that prevent AVD. Dyspnea was measured by two different scales and submaximal exercise capacity by 6MWT. RESULTS: 40 subjects with COPD and 40 healthy controls were evaluated. Patients with COPD performed less time walking (68.5 ± 25.8 minutes / day vs. 105.2 ± 49.4; p < 0.001), shorter distance (3.9 ± 1.9 km / day vs. 6.4 ± 3.2; p < 0.001) and a smaller number of steps/day. The lack of infrastructure, social influences and unwillingness were the main barriers to performing ADLs. The 6MWT correlated with the results of the accelerometer, but not LCADL. CONCLUSION: Patients with COPD are less active compared to healthy adults. Sedentary and barriers to physical activity has immediate implications in clinical practice indicating early intervention measures
43

"Estudo dopplervelocimétrico das artérias uterinas em três períodos de gestações normais" / Study of the uterine arteries Doppler ultrasound in three periods of normal pregnancies

Sakamoto, Kathia 02 October 2003 (has links)
Estudo longitudinal, prospectivo, comparativo de avaliação dopplervelocimétrica das artérias uterinas direita e esquerda em 37 gestantes normais em três períodos da gestação, acompanhadas na Clínica Obstétrica do HCFMUSP. Análise da relação S/D, índice de pulsatilidade e índice de resistência, relação com o número de incisuras e com posição da placenta. Foi observada redução nos valores dos índices durante a gestação. A relação S/D AUTE com placenta a direita apresentou média superior. A incidência de incisura foi maior no período entre a 16ª e a 24ª semana de gestação. A análise da relação entre os índices dopplervelocimétricos e a presença de incisura não teve resultados significativos / Prospective, longitudinal, comparative study of Doppler evaluation of the right and left uterine arteries of 37 healthy women with singleton pregnancies, performed in three periods of pregnancy, at the Pre-Natal Care Unit HCFMUSP. S/D ratio, pulsatility index and resistance index, number of notches and placental position were analysed. A decrease in the indices was observed with advancing gestation. When placenta was on the right side, the left uterine artery S/D ratio showed increased mean values. The incidence of uterine notch was higher between the 16th and 24th week of gestation in both arteries. No correlation was found between the presence of uterine notch and the placental position
44

"Estudo dopplervelocimétrico das artérias uterinas em três períodos de gestações normais" / Study of the uterine arteries Doppler ultrasound in three periods of normal pregnancies

Kathia Sakamoto 02 October 2003 (has links)
Estudo longitudinal, prospectivo, comparativo de avaliação dopplervelocimétrica das artérias uterinas direita e esquerda em 37 gestantes normais em três períodos da gestação, acompanhadas na Clínica Obstétrica do HCFMUSP. Análise da relação S/D, índice de pulsatilidade e índice de resistência, relação com o número de incisuras e com posição da placenta. Foi observada redução nos valores dos índices durante a gestação. A relação S/D AUTE com placenta a direita apresentou média superior. A incidência de incisura foi maior no período entre a 16ª e a 24ª semana de gestação. A análise da relação entre os índices dopplervelocimétricos e a presença de incisura não teve resultados significativos / Prospective, longitudinal, comparative study of Doppler evaluation of the right and left uterine arteries of 37 healthy women with singleton pregnancies, performed in three periods of pregnancy, at the Pre-Natal Care Unit HCFMUSP. S/D ratio, pulsatility index and resistance index, number of notches and placental position were analysed. A decrease in the indices was observed with advancing gestation. When placenta was on the right side, the left uterine artery S/D ratio showed increased mean values. The incidence of uterine notch was higher between the 16th and 24th week of gestation in both arteries. No correlation was found between the presence of uterine notch and the placental position
45

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Neves, Itamara Lucia Itagiba 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
46

Avaliação objetiva dos hábitos e barreiras da atividade física de portadores de doença pulmonar obstrutiva crônica / Objective assessment of barriers and habits of physical activity in patients with chronic obstructive pulmonary disease

Priscila Batista de Souza Amorim 10 July 2014 (has links)
INTRODUÇÃO: Pacientes com doença pulmonar obstrutiva crônica (DPOC) tem atividade física reduzida. Barreiras que limitam a atividade física e a medida objetiva da limitação ainda são pouco estudadas nesta população. Conhece-las permite um planejamento adequado para incremento da atividade de vida diária (AVD). OBJETIVO: Comparar a AVD de portadores de DPOC e controles com um sensor de movimento, identificar barreiras que impedem a AVD e correlaciona-los à gravidade da dispneia, ao teste de caminhada de 6 minutos (TC6) e um escore de limitação da AVD. MÉTODOS: O número de passos, a distância percorrida em quilômetros e o tempo de caminhada foram registrados por um acelerômetro de bolso e um pedômetro durante 7 dias consecutivos. Um questionário de barreiras percebidas e a escala AVD (LCADL) foram utilizados para qualificar fatores que impedem a AVD. A dispneia foi medida por duas escalas distintas e a capacidade física submáxima pelo TC6. RESULTADOS: Foram avaliados 40 sujeitos com DPOC e 40 controles saudáveis. Os pacientes com DPOC realizaram tempo menor de caminhada (68,5 ± 25,8 minutos/dia vs. 105,2 ± 49,4; p < 0,001), menor distância (3,9 ± 1,9 km/dia vs. 6,4 ± 3,2; p < 0,001) e menor número de passos/dia. A falta de estrutura, influência social e falta de vontade foram as principais barreiras referidas para realização de AVD. O TC6 correlacionou-se com os resultados do acelerômetro, mas o LCADL não. CONCLUSÃO: Portadores de DPOC são menos ativos quando comparados a adultos saudáveis. Sedentarismo e as barreiras para atividade física tem implicação imediata na prática clínica indicando medidas de intervenção precoce / INTRODUCTION: Patients with chronic obstructive pulmonary disease (COPD) have reduced physical activity. Barriers that limit physical activity and objective measures of limitation are poorly studied in this population. The knowledge of them allows a proper planning for increased physical activity. OBJECTIVES: To compare ADLs in COPD patients and controls using a motion sensor, identify perceived barriers that prevent AVD and correlate them to the severity of dyspnea, to the 6-minute walk test (6MWT) and a score of AVD limitation. METHODS: An pocket accelerometer and a pedometer recorded the number of steps, distance in Km and walking time for seven consecutive days. A survey of perceived barriers and the ADL scale (LCADL) were used to describe factors that prevent AVD. Dyspnea was measured by two different scales and submaximal exercise capacity by 6MWT. RESULTS: 40 subjects with COPD and 40 healthy controls were evaluated. Patients with COPD performed less time walking (68.5 ± 25.8 minutes / day vs. 105.2 ± 49.4; p < 0.001), shorter distance (3.9 ± 1.9 km / day vs. 6.4 ± 3.2; p < 0.001) and a smaller number of steps/day. The lack of infrastructure, social influences and unwillingness were the main barriers to performing ADLs. The 6MWT correlated with the results of the accelerometer, but not LCADL. CONCLUSION: Patients with COPD are less active compared to healthy adults. Sedentary and barriers to physical activity has immediate implications in clinical practice indicating early intervention measures
47

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Itamara Lucia Itagiba Neves 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
48

Wearable Systems For Health Monitoring Towards Active Aging

Majumder, Sumit January 2020 (has links)
Global rise in life expectancy has resulted in an increased demand for affordable healthcare and monitoring services. The advent of miniature and low–power sensor technologies coupled with the emergence of the Internet–of–Things has paved the way towards affordable health monitoring tools in wearable platforms. However, ensuring power–efficient operation, data accuracy and user comfort are critical for such wearable systems. This thesis focuses on the development of accurate and computationally efficient algorithms and low–cost, unobtrusive devices with potential predictive capability for monitoring mobility and cardiac health in a wearable platform. A three–stage complementary filter–based approach is developed to realize a computationally efficient method to estimate sensor orientation in real–time. A gradient descent–based approach is used to estimate the gyroscope integration drift, which is subsequently subtracted from the integrated gyroscope data to get the sensor orientation. This predominantly gyroscope–based orientation estimation approach is least affected by external acceleration and magnetic disturbances. A two–stage complementary filter–based efficient sensor fusion algorithm is developed for real–time monitoring of lower–limb joints that estimates the IMU inclinations in the first stage and uses a gradient descent–based approach in the second stage to estimate the joint angles. The proposed method estimates joint angles primarily from the gyroscope measurements without incorporating the magnetic field measurement, rendering the estimated angles least affected by any external acceleration and insensitive to magnetic disturbances. An IMU–based simple, low–cost and computationally efficient gait–analyzer is developed to track the course of an individual's gait health in a continuous fashion. Continuous monitoring of gait patterns can potentially enable detecting musculoskeletal or neurodegenerative diseases at the early onset. The proposed gait analyzer identifies an anomalous gait with moderate to high accuracy by evaluating the gait features with respect to the baseline clusters corresponding to an individual’s healthy peer group. The adoption of a computationally efficient signal analysis technique renders the analyzer suitable for systems with limited processing capabilities. A flexible dry capacitive electrode and a wireless ECG monitoring system with automatic anomaly detection capability are developed. The flexible capacitive electrode reduces motion artifacts and enables sensing bio–potential over a dielectric material such as cotton cloth. The virtual ground of the electrode allows for obtaining single–lead ECG using two electrodes only. ECG measurements obtained over different types of textile materials and in presence of body movements show comparable performance to other reported ECG monitoring systems. An algorithm is developed separately as a potential extension of the software to realize automatic identification of Atrial Fibrillation from short single–lead ECGs. The association between human gait and cardiac activities is studied. The gait is measured using wearable IMUs and the cardiac activity is measured with a single–lead handheld ECG monitor. Some key cardiac parameters, such as heart rate and heart rate variability and physical parameters, such as age and BMI show good association with gait asymmetry and gait variation. These associations between gait and heart can be useful in realizing low–cost in–home personal monitoring tool for early detecting CVD–related changes in gait features before the CVD symptoms are manifested. / Thesis / Doctor of Philosophy (PhD) / Wearable health monitoring systems can be a viable solution to meet the increased demand for affordable healthcare and monitoring services. However, such systems need to be energy–efficient, accurate and ergonomic to enable long–term monitoring of health reliably while preserving user comfort. In this thesis, we develop efficient algorithms to obtain real–time estimates of on–body sensors' orientation, gait parameters such as stride length, and gait velocity and lower–limb joint angles. Furthermore, we develop a simple, low–cost and computationally efficient gait–analyzer using miniature and low–power inertial motion units to track the health of human gait in a continuous fashion. In addition, we design flexible, dry capacitive electrodes and use them to develop a portable single–lead electrocardiogram (ECG) device. The flexible design ensures better conformity of the electrode to the skin, resulting in better signal quality. The capacitive nature allows for obtaining ECG signals over insulating materials such as cloth, thereby potentially enabling a comfortable means of long–term cardiac health monitoring at home. Besides, we implement an automatic anomaly detection algorithm that detects Atrial Fibrillation with good accuracy from short single–lead ECGs. Finally, we investigate the association between gait and cardiac activities. We observe that some important cardiac signs, such as heart rate and heart rate variability and physical parameters, such as age and BMI show good association with gait asymmetry and gait variation.

Page generated in 0.028 seconds