• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 24
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 126
  • 45
  • 23
  • 22
  • 18
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

From Particle-Production Cross Sections to KERMA and Absorbed Dose for the Case 96 MeV n-12C Interactions / Från partikelproduktionstvärsnitt till KERMA och absorberad dos för fallet 96 MeV n-12C växelverkningar

Bergenwall, Bel E. January 2004 (has links)
Neutron-carbon interactions have been studied with a focus on charged-particle production of relevance to radiation protection and medical applications, such as cancer therapy. The measurements have been performed using the particle-detection setup, MEDLEY, and the 96 MeV neutron beam at the The Svedberg Laboratory in Uppsala. Double-differential cross sections of inclusive charged-particle production are compared with recent calculations from models based on the GNASH code including direct, preequilibrium and compound processes. For protons, the shapes of the cross-section spectra are reasonably well described by the calculations. For the other particles- d, t, 3He and α- there are important discrepancies, in particular for 3He-ions and α-particles, concerning both shape and magnitude of the spectra. Using the new cross sections, partial as well as total KERMA coefficients have been determined. The coefficients have also been compared to previous experimental results and model calculations. The p, d and t KERMA coefficients are in good agreement with those from a previous measurement. For the helium isotopes, there are no previous measurements at this energy. The KERMA coefficients are considerably higher (by up to 30%) than those predicted by the calculations. The KERMA results indicate that protons and α -particles are the main contributors to the dose. A 6x6x6 cm3 carbon phantom, exposed to a broad and a pencil-like beam, is used for the computation of the absorbed doses deposited by these two particles in spheres of 1 μm in diameter, located at various positions in the phantom. The maximum doses are deposited at ~3 cm from the surface of neutron impact for protons and within 1 cm for α-particles. For the pencil beam, deposited doses are spread over regions of ~1.5 cm and ~300 μm transverse to the beam for protons and α-particles, respectively. The results are consistent with previous integral measurements at lower energies.
112

Machbarkeitstudie für einen industriellen supraleitenden Table Top Elektronenbeschleuniger

Janssen, Dietmar, Pobell, Frank, Gabriel, Frank, Schneider, Christof, Michel, Peter, Enghardt, Wolfgang, Kudryavtsev, A., Haberstroh, Christoph, Sandner, W., Will, I., Prade, Haral, Büttig, Hartmut 31 March 2010 (has links) (PDF)
At the Forschungszentrum Rossendorf the build-up of the superconducting 1.3 GHz accelerator ELBE is still in progress. Furthermore a new sc photo injector (SRF gun) is under development, which should accelerate electrons up to 10 MeV at 1.3 GHz frequency. The use of electron accelerators is also more and more interesting for applications where the destructive potential of the electrons are used like sterilization of medical waste and medical products, food irradiation or decontamination of sewage. For these processes a high power is required to achieve a high product throughput in a plant. The aim is therefore to use beam powers of around 100 kW or more. Since the applications of electron accelerators in industrial environments are steadily increasing one can speculate about transferring the above named state of the arte technology to industrial electron accelerators. At the FZR a feasibility study of such a table top electron accelerator (TTE) has been performed to investigate its technical limits and marketabilitys.
113

Estudo da degradação de ponteiras de endoscópios utilizadas em endoscopia digestiva alta. / Study of the degradation of endoscopes tips used in upper digestive endoscopy.

ANDRADE, Antônio Augusto Fraga de. 17 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-17T12:25:43Z No. of bitstreams: 1 ANTÔNIO AUGUSTO FRAGA DE ANDRADE - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2871535 bytes, checksum: c0965a012ab765af77feb84c2c22a016 (MD5) / Made available in DSpace on 2018-04-17T12:25:43Z (GMT). No. of bitstreams: 1 ANTÔNIO AUGUSTO FRAGA DE ANDRADE - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2871535 bytes, checksum: c0965a012ab765af77feb84c2c22a016 (MD5) Previous issue date: 2014-12-18 / O aparelho endoscópico utilizado atualmente para estudo do trato gastro-intestinal (o video-endoscópio) é resultado de quase 200 anos de evolução tecnológica. Estes endoscópios não podem ser esterilizados pelos métodos clássicos. Por sua complexidade, o processo de limpeza e desinfecção de endoscópios não é somente uma preocupação da enfermagem, ela se tornou multidisciplinar, pois exige discussão sobre riscos físicos, biológicos e químicos, tanto para o paciente quanto para a equipe. A borracha da ponta flexível dos endoscópios é uma peça fundamental para a preservação da vedação do endoscópio e principalmente preservação do paciente. Esta borracha sofre desgaste tanto durante o exame como pelos processos de desinfecção do equipamento que acabam agredindo a superfície do material. O seu desgaste ou ruptura pode acarretar na queima do gerador de imagem. A troca da borracha da ponta é considerada uma manutenção parcial e deve sempre ser executada periodicamente. Baseado no exposto este trabalho teve como objetivo principal estudar e avaliar a degradação ocorrida em ponteiras flexíveis de endoscópios digestivos submetidos a procedimentos médicos. Como resultados pode-se verificar nas microscopia, tanto ótica como eletrônica, morfologia rugosa com presença de poros para a ponteira virgem, nas ponteiras utilizadas por diferentes períodos de tempo verificou-se intensificação destas rugosidades. Por DRX pode-se observar um perfil praticamente amorfo típico de elastômero, além de identificar a presença de compostos de carga no polímero. Por FTIR pode-se comprovar diferentes estruturas para as amostras estudadas, levando a crer que algumas possuem polidimetilsiloxana em excesso com relação ao fluorelastômero. Por EDS pode-se verificar a exteriorização de compostos presentes no interior do elastômero após o período de degradação. No ensaio de tração foi verificada diminuição das propriedades físicas do elastômero devido a degradação ocorrida. No ensaio de ângulo de molhabilidade verificou-se que mesmo após o processo de degradação todas as amostras ainda apresentavam-se hidrofóbicas. Em síntese, este trabalho observou a necessidade de se desenvolver um material específico para utilização como ponteiras de endoscópios, já que os existentes no mercado aparentemente não tem destino especifico para aplicações biológicas. Ou seja, mesmo em sua forma virgem o elastômero em questão já apresenta fatores que não tornam sua utilização em meio biológico tão viável. / The endoscopic device currently used to study the gastrointestinal tract (the videoendoscope) is the result of nearly 200 years of technological evolution. These endoscopes can not be sterilized by the classical methods. Due to its complexity, the process of cleaning and disinfection of endoscopes is not only a concern of nursing, she became multidisciplinary, since it requires discussion of physical, biological and chemical hazards, both for the patient and for the team. The flexible rubber tip of the endoscope is a key piece to preserve the seal of the endoscope and especially preservation of the patient. This rubber wears out both during the test as the disinfection of equipment that processes attacking the end surface of the material. Your wear or breakage may result in the image generator burns. The replacement of the rubber tip is considered a partial maintenance and must always be performed periodically. Based on the above this work aimed to study and evaluate the degradation occurred in flexible tips of digestive endoscopes undergoing medical procedures. The results can be seen in microscopy, both optical and electronic, rough morphology with the presence of pores to the virgin tip, the tips used for different periods of time there was intensification of these ridges. XRD can observe typical listing a substantially amorphous elastomer, and identify the presence of compounds in the polymer charge. FTIR can prove different structures for the studied samples, leading to the belief that some have polydimethylsiloxane in excess with respect to the fluoroelastomer. EDS can verify the externalization of compounds within the elastomer after the degradation period. In the tensile test was observed decrease in physical properties of the elastomer due to degradation occurred. On test wetting angle was found that even after the degradation process all the samples still had become hydrophobic. In summary, this study observed the need to develop a specific material for use as tips of endoscopes, since on the market apparently has no specific target for biological applications. That is, even in its virgin form the elastomer in question already has factors that do not make their use in biological environment as possible.
114

[en] MICROSCOPY OF BIOFILMS FORMED ON A METALLIC SUBSTRATE IN THE PRESENCE OF OILY FLUIDS IN STATIC AND DYNAMIC SYSTEMS / [pt] MICROSCOPIA DE BIOFILMES EM SUBSTRATO METÁLICO FORMADO EM SISTEMAS ESTÁTICO E DINÂMICO NA PRESENÇA DE FLUIDO OLEOSO

KARLA DE AVELLAR MOTA 12 January 2018 (has links)
[pt] Este trabalho teve por objetivo avaliar a morfologia de biofilmes, formados em superfície de aço API 5L X80 submetida a um fluido com baixo BSW (Basic Sediment Water), ou seja, baixo teor de água em óleo, através de análise por Microscopia Eletrônica de Varredura (MEV), determinar a cinética e quantificar os grupos bacterianos de formação destes biofilmes, e avaliar a biocorrosão causada por estes microrganismos. Foram realizadas alterações no protocolo original de preparo de amostras, com a finalidade de obter melhor definição das morfologias avaliadas. Realizaram-se estudos dinâmicos (looping) e em condições estáticas, com e sem a adição de agente biocida. Utilizando-se como fluido de processo o óleo coletado no terminal da Petrobras em Barra do Furado que tem como característica um BSW de aproximadamente 1 por cento de água. Para alcançar os objetivos descritos foram quantificadas bactérias sésseis (bactérias facultativas heterotróficas, bactérias precipitantes do ferro, bactérias anaeróbias heterotróficas e bactérias redutoras de sulfato) através da técnica do número mais provável (NMP). A intensidade do processo corrosivo foi avaliada através da análise dos pites formados nos cupons por microscopia óptica. A seqüência de fixação com alteração do protocolo inicial, permitiu uma melhor preservação estrutural do biofilme obtendo-se assim imagens com melhor resolução, tendo em vista que a fixação primária com glutaraldeído fixa principalmente proteínas pelo estabelecimento de ligações divalentes com grupamento amino, e a pós-fixação em tetróxido de ósmio reage com os lipídios. Quanto a cinética, observou-se também que na presença de fluido oleoso, a formação do biofilme só é detectada após 15 dias de exposição. A adição do agente biocida inibiu o crescimento do biofilme, não sendo detectada a presença de células cultiváveis após 7 dias em contato com o fluido contendo o agente químico. / [en] This study aims to evaluate the morphology of biofilms formed on the surface of API 5L X80 steel exposed to a low BSW (Basic Sediment Water) fluid comprising oil of a low water content. The analisys was performed using scanning electron microscopy (SEM) in order to determine the formation kinetics, to quantify and identify the bacterial groups present as the film formed, and to evaluate the biocorrosion caused by these organisms. Modifications were made to the original sample preparation protocol, in order to better define the film morphologies. Studies were undertaken applying either static or dynamic (looping) conditions, bith with and without the addition of biocides. The process fluid used was oil collected from the Petrobras Barra do Furado Terminal, characterized by its 1 percent BSW. The evaluation was performed quantifying the sessile bacteria present in the film (heterotrophic bacteria, iron bacteria, anaerobic bacteria e sulphate reducing bacteria) via the Most Probable Number (MPN) technique. The intensity of the corrosion process was determined by the analysis of pits forme in the testpieces, by optical microscopy. The application of a sample fixation sequence, in addition to modifications of the inicial sample preparation protocol, permitted the improved preservation of the biofilm structures, thereby permitting higher resolution images. The primary fixing agent, containing gluteraldehyde, principally fixes proteins, by establishing divalent bonds with amino groups, while the post-fixation stage with osmium tetroxide invloves reactions with lipid groups.With regard to the film deposition kinetics, it was observed that biofilm formation could only be detected after 15 day s exposure to the oily fluid. The addition of a biocide, inhibited the growth of the film, no cultivatable cells being present after 7 days contact with the treated fluid.
115

Estados de alto spin e inversao por assinatura no Brsup78

LANDULFO, EDUARDO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:52Z (GMT). No. of bitstreams: 1 05403.pdf: 3608647 bytes, checksum: 066e3f6af2ef001c7431582e2ce35791 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:96/01220-7
116

Análise das propriedades estruturais, morfológicas e mecânicas de duas marcas comerciais diferentes de dissilicato de lítio para o sistema CAD/CAM

Tavares, Lucas do Nascimento 14 February 2017 (has links)
O objetivo deste presente estudo foi comparar duas marcas comerciais diferentes de Dissilicato de Lítio para o sistema CAD / CAM (IPS e.max CAD e Rosetta SM CAD / CAM), avaliando suas propriedades estruturais, morfológicas e mecânicas. Para avaliar as propriedades estruturais foram necessárias duas amostras de cada grupo, para serem analisadas por meio do DRX (difração de raios X). As propriedades morfológicas foram analisadas utilizando o MEV (Microscopia eletrônica de Varredura) antes e depois do tratamento térmico, e o teste de porosidade, realizado através de uma tomografia computadorizada em 3D (micro-CT). Para avaliar as propriedades mecânicas foi realizado o teste flexural de três pontos e o teste de microcisalhamento, e para isto foram selecionados dez espécimes de cada grupo para cada teste. Os valores médios de porosidade e da resistência flexural de três pontos foram analisados pelo teste t e a resistência de união obtida através do microcisalhamento foi analisada pelo teste Anova Two-way. Todos os testes usaram um nível de significância de α = 0,05. Os resultados obtidos pela análise estrutural realizada pelo DRX apresentaram picos no difractograma correspondentes ao Metassilicato de Lítio e o Dissilicato de Lítio, com intensidades semelhantes para ambos os grupos testados. Após realizar a microscopia eletrônica de varredura, não foi encontrado diferenças na morfologia dos cristais, em ambas as cerâmicas testadas, antes e depois do tratamento térmico. O teste de porosidade não mostrou diferença estatisticamente significativa entre o valor total de poros encontrados. Ambos os resultados dos testes mecânicos não apresentaram diferenças estatísticas significativas entre os grupos avaliados. Baseado nos resultados encontrados, não houve diferença entre as duas marcas comerciais testadas, em relação as suas propriedades estruturais, morfológicas e mecânicas. / The aim of the present study was to compare two different brands of lithium disilicate CAD/CAM blocks (IPS e.max CAD and Rosetta SM CAD/CAM), evaluated by structural, morphological and mechanical properties. Two specimens of each group were analyzed using x-ray diffraction (XRD) to evaluate the structures of the ceramic material. Morphologic properties were analyzed using the Scanning Electron Microscopy (SEM) before and after the heat treatment; and porosity test was performed using a 3D micro-computed tomography analyses (micro-CT). Ten specimens of each group were submitted to three-point flexure strength and microshear bond strength tests, to analyze the mechanical properties of both brands. Mean values of porosity test and three-axial flexural strength were analyzed by t Test, and the microshear bond strength was analyzed by Anova two-way. All tests used a significance level of α=0.05. The structure results performed by XDR, presented high peak positions corresponding to the standard lithium metasilicate and lithium disilicate, with similar intensities for both tested groups. The morphologic results demonstrated similar patterns of crystalline structure, before and after the heat treatment and the porosity test showed no difference between the number and size of the pores found. Both mechanical tests results did not present statistically significant differences between the samples. Based on the results, there was no difference in relation to their structural, morphological and mechanical properties, between the two commercial brands tested. / Dissertação (Mestrado)
117

Estados de alto spin e inversao por assinatura no Brsup78

LANDULFO, EDUARDO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:52Z (GMT). No. of bitstreams: 1 05403.pdf: 3608647 bytes, checksum: 066e3f6af2ef001c7431582e2ce35791 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:96/01220-7
118

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Francielle Alves Mendes 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
119

Desenvolvimento de um método simplificado para obtenção de adesão à zircônia / Development of a simplified method for obtaining membership of the zirconia

Ogliari, Aline de Oliveira 10 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_aline_oliveira_ogliari.pdf: 2899521 bytes, checksum: 3a5e7870376f999dd52a171e479c76e9 (MD5) Previous issue date: 2012-12-10 / The aim of this study was to develop a simplified method for bonding to yttriastabilized zirconia ceramic. The method was based on deposition of a reactive silica layer on the ceramic surface followed by heat treatment. The study comprised six steps: (i) preparation of solutions using four concentrations of tetraethyl orthosilicate (TEOS) and zirconium tert-butoxide (ZTB) diluted in hexane; (ii) cutting and polishing of the zirconia substrate; (iii) organic silica-based treatment before (infiltration, INF) or after (coating, COA) zirconia sintering; (iv) analysis by scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS); (v) G-Raman confocal spectroscopy analysis; (vi) shear bond strength to zirconia tested after 24-h and failure analysis. An untreated (control) and a commercial reference (Rocatec Plus, 3M ESPE) groups were tested. Quantitative data were analyzed using ANOVA and Tukey s post hoc test (P < 0.05). SEM micrographs showed that zirconia surface was covered by silica nanoparticle clusters. EDS and G-Raman analyses confirmed composition of this layer. The bond strength results showed that most groups that received coating (COA) and infiltration (INF) presented higher bonding potential than the untreated (control) group. Almost all experimental groups were similar to commercial reference. Mixed failures were predominant. In conclusion, the present study introduces a novel, simple, and cost-effective method to provide adhesion to yttria-stabilized zirconia ceramic. Both the method of silica deposition (if before or after zirconia sintering) and concentration of organic silica precursors have a significant impact on the adhesion of methacrylates to the treated zirconia / O objetivo deste estudo foi desenvolver um método simplificado para obtenção de adesão a uma cerâmica de zircônia estabilizada por ítria. O método foi baseado na deposição de uma camada reativa de sílica na superfície cerâmica seguida por tratamento térmico. O estudo compreendeu seis etapas: (i) preparo de 4 soluções contendo tetraetilortosilicato (TEOS) e tert-butóxido de zircônio (ZTB) diluídos em hexano; (ii) corte e polimento do substrato de zircônia; (iii) tratamento com os precursores orgânicos antes (infiltração, INF) ou depois (cobertura, COA) da sinterização da zircônia; (iv) análise por microscopia eletrônica de varredura e espectroscopia de energia dispersiva (MEV-EDS); (v) análise por espectroscopia confocal G-Raman; (vi) avaliação de resistência de união ao cisalhamento 24h após preparo e análise de falha. Grupos sem tratamento (controle) e uma referência comercial (Rocatec Plus, 3M ESPE) foram testados. Dados quantitativos foram analisados usando ANOVA e teste post hoc de Tukey (P < 0,05). Os resultados de MEV mostraram que a superfície da zircônia foi coberta por aglomerados de nanopartículas de sílica, sendo esta composição confirmada por EDS e análise de G-Raman. Os resultados do teste mecânico mostraram que a maioria dos grupos que receberam cobertura (COA) e infiltração (INF) apresentaram maior resistência de união que o grupo sem tratamento (controle). A maioria dos grupos experimentais foram similares à referência comercial. Falhas do tipo mistas foram predominantes. Em conclusão, o presente estudo introduz um método novo, simples e de baixo custo para promover adesão a cerâmicas de zircônia estabilizada por ítria. Tanto o método de deposição de sílica (se antes ou após sinterização da zircônia) e a concentração de precursores orgânicos de sílica têm impacto significativo na adesão de metacrilatos à cerâmica tratada
120

Breakup reactions populating cluster states in 28Si and 24Mg

Shawcross, Mark January 1999 (has links)
The 12C+16O breakup of 28Si and the 12C+12C breakup of 24Mg have been studied following the interaction of a 170 MeV 24Mg beam with 7Li, 9Be,12C and 16O target nuclei. The measurements were performed at the Australian National University in Canberra, using the technique of Resonant Particle Spectroscopy. The breakup fragments from the decay of the resonant nuclei were detected in two Gas-Si-CsI telescopes positioned on opposite sides of the beam axis. The data suggest that the same states in 28Si are populated via the 7Li(24Mg, 12C 16O)3H, 9Be(24Mg,12C 16O)5He and 12c(24Mg,12C 16O)8Be reactions. This implies that the cluster decaying states are populated by direct a-transfer. Breakup has been observed from states in 28Si at excitation energies (spins) of (26.15), 28.17 (13-, 29.51, 29.95, 30.45, 30.76, (31.3), 31.65, 31.90, 32.51, 33.14, 33.41, 33.77, 34.45 (12+,14+) and 35.13 MeV. A consistent theoretical interpretation of the 28Si molecular structures has been given, taking into account the predictions of Nilsson-Strutinsky, a-cluster model and two centre shell model calculations. The present results for the 12C(24Mg,12C 12C)12C reaction agree with previous measurements. In addition, new spin assignments have been proposed for several of the breakup states in 24Mg. States have been observed at excitation energies (spins) of 20.54 (2+), 21.07 (4+), 21.88 (4+), 22.33 (4+), 22.90 (6+), 23.80 (6+,(8+)), 24.56 (8+), 25.14 (6+), 25.72, 26.41 (8+) and 27.12 MeV. Evidence for the population of many of these states via the 16O(24Mg,12C 12C)16O reaction has also been observed. However, the data gave no evidence for either the 7Li(24Mg,12C 12C)7Li or 9Be(24Mg,12C 12C)9Be reactions. The presently available information did not allow an unambiguous determination of the reaction mechanism responsible for the population of the 24Mg breakup states. The performance of the Gas-Si-Csl telescopes has been investigated. For multiplicity 2 events in the silicon strip detectors, a crosstalk has been observed between the two active strips. The energy calibration of the silicon strip detectors for penetrating particles has also been found to differ to that for stopped particles. Empirical corrections for both of these effects have been deduced allowing the simultaneous detection and identification of heavy and light ions within a single telescope. These techniques have been extended to the detection of 8Be &rarr; alpha+alpha events over a wide range of alpha-particle energies.

Page generated in 0.0235 seconds