Spelling suggestions: "subject:"media (matematica)"" "subject:"media (matematical)""
1 |
Metodo da media e aplicaçõesBorges, Marcia Aparecida Ancheazzi 14 July 2018 (has links)
Orientador: Orlando Francisco Lopes / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Científica / Made available in DSpace on 2018-07-14T12:11:52Z (GMT). No. of bitstreams: 1
Borges_MarciaAparecidaAncheazzi_M.pdf: 1613436 bytes, checksum: e8d71bcdb597791eb280411b8705ecdc (MD5)
Previous issue date: 1977 / Resumo: Não informado. / Abstract: Not informed. / Mestrado / Mestre em Matemática
|
2 |
Expectancia de quadrados medio em experimentos aleatorizados com estrutura balanceada e completaPinho, Andre Luis Santos de 09 January 1996 (has links)
Orientador: Euclydes Custodio de Lima Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matemática, Estatística e Ciência da Computação / Made available in DSpace on 2018-07-21T04:57:34Z (GMT). No. of bitstreams: 1
Pinho_AndreLuisSantosde_M.pdf: 2639435 bytes, checksum: caa21ed212b2c79fb9d970e328a8e006 (MD5)
Previous issue date: 1995 / Resumo: Não informado. / Abstract: Not informed. / Mestrado / Mestre em Estatística
|
3 |
A media movel ponderada exponencialmente como alternativa a X na construção de graficos de controleAlexandre, João Welliandre Carneiro 01 March 1990 (has links)
Orientador : Sebastião de Amorim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Ciencia da Computação / Made available in DSpace on 2018-07-15T06:26:53Z (GMT). No. of bitstreams: 1
Alexandre_JoaoWelliandreCarneiro_M.pdf: 906088 bytes, checksum: c36cb6c2800577576941276b63f38c60 (MD5)
Previous issue date: 1989 / Resumo: Não informado. / Abstract: Not informed. / Mestrado / Mestre em Estatística
|
4 |
Validação do analisador hematológico automático BC-2800 VET® para realização de hemogramas de muares /Miranda, Gislaine Matias Dantas. January 2014 (has links)
Resumo:Neste estudo foram comparados os valores do hemograma completo realizado em 30 muares com idade entre 4 e 8 anos, obtidos pelo uso de um analisador hematológico automático e pela contagem manual de células sanguíneas. A análise dos resultados revelou que a concordância entre os dois métodos foram considerados bons uma vez que o viés (média das diferenças) foi pequeno, sendo que os intervalos de confiança de 95% para o viés apresentaram-se estreitos e apenas um "outlier" foi observado, para eritrócitos, monócitos e granulócitos (nenhum valor caiu fora dos limites de concordância [viés ± 2 desvios padrão]). Não houve diferença significativa para os valores de eritrócitos, hemoglobina, leucócitos e granulócitos. Os valores médios de monócitos obtidos pelo contador automático de células foram significativamente maiores do que aqueles obtidos pelo método manual. A análise dos resultados revelou ainda um viés positivo para hematócrito e nenhum viés foi detectado para eritrócitos, hemoglobina, leucócitos, granulócitos e linfócitos. Foi observada boa concordância entre os resultados obtidos pelos dois métodos para eritrócitos, hemoglobina, leucócitos, granulócitos, linfócitos e monócitos nessa faixa etária. Podendo o Analisador hematológico automático BC- 2800Vet®, ser utilizado para realização de hemogramas em muares / Abstract:In this study the values of complete blood counts performed in 30 mules aged 4 and 8, obtained by using an automated hematology analyzer and the manual blood counts were compared. The results showed that the correlation between the two methods were considered good since the bias (mean difference) was small, and the confidence intervals of 95 % for the bias showed up narrow and only one "outlier" was observed for erythrocytes, monocytes and granulocytes (no value fell outside the limits of agreement [bias ± 2 standard deviations]). There was no significant difference in the values of erythrocytes, hemoglobin, leukocytes and granulocytes. The average values obtained from monocytes by an automatic cell counter were significantly higher than those obtained by the manual method. The results also showed a positive bias for hematocrit and no bias was detected in erythrocytes, hemoglobin, leukocytes, granulocytes and lymphocytes. Good agreement between the results obtained by the two methods for erythrocytes, hemoglobin, leukocytes, granulocytes, lymphocytes and monocytes was observed in this age group. Can the automated hematology analyzer BC-2800Vet® be used to perform complete blood counts in mules / Orientador:Luiz Cláudio Nogueira Mendes / Banca:Lina Maria Wehrle Gomide / Banca:Raimundo Souza Lopes / Mestre
|
5 |
Validação do analisador hematológico automático BC-2800 VET® para realização de hemogramas de muaresMiranda, Gislaine Matias Dantas [UNESP] 28 February 2014 (has links) (PDF)
Made available in DSpace on 2015-10-06T13:03:14Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-28. Added 1 bitstream(s) on 2015-10-06T13:18:46Z : No. of bitstreams: 1
000849287.pdf: 230262 bytes, checksum: 43cb89c8000a95aa870bb4e1a18fdf53 (MD5) / In this study the values of complete blood counts performed in 30 mules aged 4 and 8, obtained by using an automated hematology analyzer and the manual blood counts were compared. The results showed that the correlation between the two methods were considered good since the bias (mean difference) was small, and the confidence intervals of 95 % for the bias showed up narrow and only one outlier was observed for erythrocytes, monocytes and granulocytes (no value fell outside the limits of agreement [bias ± 2 standard deviations]). There was no significant difference in the values of erythrocytes, hemoglobin, leukocytes and granulocytes. The average values obtained from monocytes by an automatic cell counter were significantly higher than those obtained by the manual method. The results also showed a positive bias for hematocrit and no bias was detected in erythrocytes, hemoglobin, leukocytes, granulocytes and lymphocytes. Good agreement between the results obtained by the two methods for erythrocytes, hemoglobin, leukocytes, granulocytes, lymphocytes and monocytes was observed in this age group. Can the automated hematology analyzer BC-2800Vet® be used to perform complete blood counts in mules
|
6 |
Estudo de ciclos limites em uma classe de equações diferenciais descontínuas /Carvalho, Yagor Romano. January 2016 (has links)
Orientador: Luci Any Francisco Roberto / Banca: Pedro Toniol Cardin / Banca: Weber Fl'avio Pereira / Resumo: Neste trabalho temos como principal objetivo determinar quota inferior para o número máximo de ciclos limites de um sistema diferencial polinomial de Liénard descontínuo de grau n com m zonas, para m=2,4. A principal ferramenta é uma combinação da Teoria da Média de primeira ordem com o processo de regularização de sistemas descontínuos. Analisamos detalhadamente um caso particular de um sistema polinomial de Liénard de grau 3 com 4 zonas / Abstract: In this work our main aim is to determine the lower upper bound for the maximum number of limit cycles of a m-piecewise discontinuous Liénard polynomial differential system of degree n, for m=2,4. The main tool is a combination of the first order Averaging Method with the regularization process of discontinuous systems. We analyzed in details a particular case of a 4-piecewise discontinuous Liénard polynomial differential system of degree 3 / Mestre
|
7 |
Médias : aritmética, geométrica e harmônica / Means : arithmetic, geometric and harmonicPereira, Jakson Da Cruz, 1981- 25 August 2018 (has links)
Orientador: Antônio Carlos Patrocinio / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Instituto de Matemática Estatística e Computação Científica / Made available in DSpace on 2018-08-25T12:22:05Z (GMT). No. of bitstreams: 1
Pereira_JaksonDaCruz_M.pdf: 1462332 bytes, checksum: 393b1f36be156bf1cdedb16da1cc3fcd (MD5)
Previous issue date: 2014 / Resumo: O presente trabalho se dedica ao estudo das médias aritmética, geométrica e harmônica. Inicialmente, definimos cada uma das médias e trabalhamos suas aplicações através da resolução de problemas. Posteriormente destacamos as desigualdades entre as médias e suas aplicações / Abstract: This dissertation is dedicated to the study of the arithmetic, geometric and harmonic means. Initially, we defined each of the means and applied its uses through problem resolution. Afterwards, we gave emphasis to the inequalities between the means and its uses / Mestrado / Matemática em Rede Nacional / Mestre em Matemática em Rede Nacional
|
Page generated in 0.091 seconds