• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 92
  • 3
  • 1
  • Tagged with
  • 233
  • 233
  • 94
  • 82
  • 81
  • 79
  • 41
  • 36
  • 25
  • 22
  • 19
  • 17
  • 16
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Desenvolvimento de objetos simuladores antropomórficos de pescoço para testes de imagem em exames com iodo

Cerqueira, Rafaela Andrade Dantas 28 March 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nuclear medicine is a medical specialty that uses radioisotopes for treatment of diseases and also for diagnosing them. A radioisotope widely used for this application is iodine 131, which is used in several studies, especially in thyroid scintigraphy. For this purpose, it is used an equipment called scintillation camera which should conform to a quality control program that determines, among other things, the tests that should be done to guarantee the quality of the medical images. For these tests it is necessary to use phantoms, which can be of various types, from simple boxes up to the exact representation of the shape of human organs. These latter are called anthropomorphic phantoms. In this study, two anthropomorphic phantoms were developed to be used in tests for image quality control measurements. These phantoms, both made of acrylic, one with a geometric shape that simulates anthropomorphically thyroid (OSCT) and the other one with anthropomorphic shape of the neck and thyroid (OSAP) were constructed to allow the permutation of prototypes that represent a normal thyroid, with hyperthyroidism and hypothyroidism. For the phantom OSCT, prototypes were also made to simulate hot and cold nodules in the gland and thyroid remnant. Images of thyroid scintigraphy of these phantoms were obtained with iodine- 131. By the images, it was determined the measures of the gland size and scintillation camera counts at each region of interest (ROI) using a DicomWorks program. The results proved the effectiveness of the phantoms for simulating either the normal or thyroid disorders. These phantoms can be used in studies for quality control of medical images and also in the training of personnel dealing with the analysis of images at nuclear medicine centers, since they adequately simulate the organ of interest. / A Medicina Nuclear é uma especialidade médica que utiliza radioisótopos para tratamento de doenças e também para obter imagens que auxiliam no diagnóstico dessas doenças. Um radioisótopo bastante utilizado para essa aplicação é o iodo 131, que é utilizado em vários estudos, principalmente em estudos de cintilografia de tireoide. Para tanto, são usados equipamentos chamados de câmaras de cintilação, que devem obedecer a um programa de controle da qualidade (PCGQ), o qual determina, entre outras coisas, os testes que devem ser feitos para garantir a qualidade das imagens médicas. É nesse momento que entram os objetos simuladores ou phantoms, que podem ser de vários tipos, desde simples caixas até a representação exata da forma de órgãos humanos. Esses últimos são chamados de objetos simuladores antropomórficos. Nesse trabalho foram desenvolvidos dois objetos simuladores antropomórficos para serem utilizados em testes de controle de imagens médicas. Esses simuladores, ambos feitos de acrílico, um com formato geométrico e com a tireoide simulada antropomorficamente (OSCT) e o outro com formato antropomórfico do pescoço e da tireoide (OSAP), foram construídos de forma a permitir a permutação de protótipos que representam uma tireoide normal, com hipertireoidismo e com hipotireoidismo. Para o phantom OSCT foram confeccionados ainda protótipos para simulação de nódulos quentes e frios na glândula. Imagens de cintilografia de tireoide desses phantoms foram obtidas com iodo 131, juntamente com as medidas dos tamanhos da glândula e as contagens de captação da câmara de cintilação de cada região de interesse (ROI) obtidas pelo programa DicomWorks. Esses dados comprovaram a eficácia dos phantoms na simulação desses exames, seja da tireoide normal ou com patologias. Esses objetos simuladores podem ser utilizados em testes dos programas para estudos de controle da qualidade das imagens médicas e também no treinamento dos profissionais envolvidos na análise das imagens nos centros de Medicina Nuclear, uma vez que simulam de forma adequada o órgão de interesse.
192

Estudio e implementación de algoritmos digitales para la mejora de la resolución temporal en sistemas de tomografía por emisión de positrones

Monzó Ferrer, José María 26 September 2012 (has links)
La Tomografía por emisión de positrones (PET, Positron Emission Tomography) es una técnica de diagnóstico médico que se encarga de mostrar imágenes de la distribución de radioisótopos dentro del cuerpo, permitiendo de esta forma observar procesos metabólicos que ocurren en su interior. Los sistemas PET se encargan de detectar pares de rayos gamma de 511KeV cada uno generados tras la aniquilación de un positrón con un electrón. De cada rayo gamma detectado, obtenemos su energía, la posición en la que el rayo es detectado y el tiempo exacto en el que el evento ha sido detectado. Denominamos tiempo de coincidencia a la diferencia de tiempos entre dos eventos. La resolución temporal de un sistema vendrá determinada por el error temporal cometido en la medida del tiempo de coincidencia. Una mejora en la resolución temporal implica una reducción del ruido de las imágenes generadas en el sistema PET. Tradicionalmente, las técnicas para la extracción del tiempo de un evento recibido han sido implementadas analógicamente. Estas técnicas permiten alcanzar una resolución temporal muy elevada. Sin embargo, la electrónica usada en las técnicas analógicas está muy adaptada a un detector específico, es compleja y poco configurable. La búsqueda de coincidencias en sistemas con muchos detectores que hacen uso de técnicas analógicas se vuelve un gran problema, pues hace necesario un incremento de la complejidad de la electrónica muchas veces inabordable. Existe una tendencia actual a reducir la electrónica analógica de los sistemas PET sustituyéndola por electrónica digital mediante una temprana digitalización de las señales de los detectores. Por tanto, deben proponerse y estudiarse algoritmos digitales para la extracción de una marca temporal de los eventos detectados. Por el momento, las técnicas digitales actuales no alcanzan las resoluciones temporales de las técnicas analógicas. El presente estudio se enmarca dentro del ámbito de los discriminadores de tiempo digitales. En el grupo de investigación, se dispone de un setup de medida con dos detectores de rayos gamma cuyas señales de salida se procesan en un front-end analógico. Las señales resultantes del front-end analógico son digitalizadas en un sistema de adquisición donde se procesan digitalmente. La búsqueda de una mejora en la resolución temporal del sistema y el hecho de que el procesado digital, todavía poco aplicado a los sistemas PET, puede proporcionar grandes mejoras en dicha resolución fueron la motivación inicial de la presente investigación. Durante la tesis, se proponen diferentes algoritmos digitales para la extracción de la información temporal de los pulsos recibidos. En un primer paso, se realiza un estado del arte a partir del cual se aportan diferentes posibles soluciones al problema. Los algoritmos propuestos están basados en bloques de procesado digital que pueden combinarse entre ellos. Estos algoritmos extraen la información temporal de las señales procesadas haciendo uso de versiones digitales adaptadas y configurables de discriminadores analógicos clásicos junto con bloques digitales que no poseen su análogo analógico. Uno de estos bloques digitales implementado se encarga de aumentar la frecuencia de muestreo mediante interpolación por filtro paso bajo, interpolando por factores x2 y x3 la señal de entrada. Entre los algoritmos analizados, el estudio propone nuevos discriminadores que se basan en hacer un cálculo digital de la carga de los pulsos recibidos, interpolados o no interpolados, obteniendo resultados mejores que con las configuraciones clásicas que trabajan con el pulso directamente adquirido y sin procesar. Para realizar el estudio del comportamiento de los discriminadores evaluados, se desarrolla una simulación que permite validar todo el sistema PET desde los detectores, generando pulsos lo más realistas posibles; la electrónica analógica, simulada mediante simuladores de tipo SPICE; y a nivel digital, estudiando el comportamiento de los algoritmos propuestos. Los algoritmos son simulados con distintas configuraciones, condiciones de jitter de reloj y ruido. Por último, todos los algoritmos propuestos son programados en la FPGA del sistema con arquitecturas que trabajan en tiempo real a medida que se vayan detectando eventos. Se definen y llevan a cabo una serie de experimentos que validan en condiciones reales en el setup de medida el funcionamiento de los discriminadores. Las medidas también permiten validar la simulación desarrollada. De esta forma, se dispone de una plataforma de test para futuras mejoras. Como conclusión final, en el trabajo se demuestra como un adecuado procesado digital de la señal permite mejorar la resolución temporal del sistema de forma considerable. El procesado digital, de gran flexibilidad frente al analógico, junto con el incremento de la velocidad de los dispositivos digitales programables y el incremento de la frecuencia de muestreo y de la integración de los convertidores analógicos-digitales (ADCs, "Analog to digital converters") hacen prever un aumento en el número de sistemas PET con estas características en un futuro no lejano y, por tanto, las soluciones investigadas en trabajos como el aquí presentado proporcionarán un aporte básico y necesario para futuros desarrollos. / Monzó Ferrer, JM. (2012). Estudio e implementación de algoritmos digitales para la mejora de la resolución temporal en sistemas de tomografía por emisión de positrones [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/17226 / Palancia
193

Optimización de la radiografía de pelvis en niños de 3 a 6 meses. Hospital Nacional Docente Madre Niño “San Bartolomé”. Enero - abril 2017

Sucasaca Carcausto, Lizeth Vaneza January 2018 (has links)
Determina la optimización de radiografía digital de pelvis antero (AP) posterior en niños de tres a seis meses en el Hospital Nacional Docente Madre Niño “San Bartolomé” entre enero - abril de 2017. EL estudio es cuantitativo, observacional, descriptivo y retrospectivo de corte transversal, cuya muestra fue compuesta por 113 imágenes radiográficas de pelvis realizadas a niños de tres a seis meses, que cumplan con los criterios de selección. La optimización de la imagen radiográfica digital de pelvis en niños de tres a seis meses en proyección antero posterior en el 73.5% fue óptima y en el 26.5% no fue óptima. Los criterios de evaluación que optimizaron la imagen radiográfica digital de pelvis en proyección antero posterior en niños de tres a seis meses fueron la simetría de la metafisis femoral (90.3%), por el contrario se observó también asimetría (9.8%); la ubicación de ambos núcleos de osificación de la cabeza femoral (95.58%), así mismo resultó no apreciable (4.5%); la simetría del ángulo acetabular (86.7%), de igual manera no evaluable (13.3%); los márgenes superiores de ambos agujeros obturadores (88.5%), igualmente no apreciable (11.5%); los bordes inferiores de ambas crestas iliacas a la misma altura (88.5%) y este resultó no apreciable (11.5%). Se concluye que la optimización de radiografía digital de pelvis antero - posterior en niños de tres a seis meses en el Hospital Nacional Docente Madre Niño “San Bartolomé” entre enero - abril de 2017 fue del 73.5%. / Tesis
194

Evaluación diagnostica ecografía transfontanelar en neonatos prematuros Hospital Regional de Cajamarca – enero a junio 2014

Espinoza Garamende, Madeleine Jessica January 2014 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Valora las características ultrasonográficas de los neonatos prematuros en el Hospital Regional de Cajamarca en el 2014. Se realizaron 147 ecografías transfontanelares en neonatos prematuros, del 01 de enero 2014 a junio 2014, en el Servicio de Diagnóstico por Imágenes. Se utilizó un ecógrafo con transductor de 5-7,5 MHz. Se efectuó un estudio de los informes ecográficos para la obtención de datos. Para las hemorragias intraventriculares (HV) se adoptó la clasificación de Papile et al. Se encontraron 76 casos (51,6%) de HV, de los cuales fueron: Según grado de HV: Grado I, 32 (21,8%); Grado II, 23 (15,6%); Grado III, 18 (12,2%) y Grado IV, 3 (2%). La HV se presentó en 41 (27,89%) prematuros leve y en 23 (15,64%) prematuros moderado, en 8 (5,44%) en prematuros extremos, y en 4 (2.72%) prematuros muy extremos. La incidencia de la HV en neonatos fue de 51,6% y la HV se presentó en más del 99%, de los cuales los grados I y II representaron el 83% de las hemorragias. Consideramos el volumen de la hemorragia respecto del volumen ventricular como un parámetro importante para clasificar la HV en grado II y III. / Trabajo de investigación
195

Nivel de conocimiento de los tecnólogos médicos en el área de radiología, sobre la ley Nº 28028 en: Hospital Nacional "Luis N. Sáenz" PNP (Castrense); Hospital Nacional Dos de Mayo (MINSA); Hospital Nacional Guillermo Almenara Irigoyen (EsSalud) y Clínica Particular (SANNA) en el año 2015

Sivincha Romero, Melisa Judit January 2017 (has links)
La presente investigación es de tipo observacional, descriptiva. Es prospectivo y de acuerdo al periodo y secuencia del estudio es transversal. Se utiliza como instrumento un cuestionario con la finalidad de recolectar información específica. El cuestionario es aplicado a una muestra de 60 tecnólogos médicos en el área de radiología para determinar el grado de conocimiento sobre la ley Nº 28028. Los resultados revelan que el 38,3% (23) tecnólogos médicos en el área de radiología tienen un conocimiento medio sobre las disposiciones generales de la ley 28028 - Ley de Regulación del Uso de Fuentes de Radiación Ionizante, un 51,7% (31) tienen un conocimiento medio sobre las autorizaciones de la ley28028, un 51,7% (31) tienen un conocimiento alto sobre las inspecciones de la ley, un 65% (39) tienen un conocimiento medio sobre el régimen sancionador de la ley 28028, un 60% (36) tienen un conocimiento medio sobre los derechos e ingresos de la ley 28028. / Tesis
196

Desenvolvimento de reagente liofilizado de glucoheptonato-estanho para marcação de leucócitos com Tecnécio-99m in vitro / Development of lyophilized kit of Tin-Glucoheptonate for in vitro labeling of leucocytes with 99mTc

Nascimento, Rosemeire Fagundes 24 August 2007 (has links)
O estudo de processos inflamatórios e infecciosos em Medicina Nuclear apresenta grande relevância para a clínica médica diagnostica. Enquanto em alguns casos o diagnóstico é óbvio, baseado na história clínica e exame físico do paciente, em outros é mais difícil, por serem assintomáticos ou por apresentarem sintomas não específicos. O diagnóstico precoce do processo inflamatório ou infeccioso permite tratamento rápido e também o impedimento de outras complicações. Além disto, a distinção entre inflamação e infecção é de extrema importância, bem como a provável localização. O uso de leucócitos radiomarcados, já estudados e aplicados em várias patologias, é o método de escolha para visualização de focos de infecção e inflamação. A cintilografia de leucócitos radiomarcados foi introduzida em 1976 por McAffe e Thakur e desde então é usada para diagnosticar diferentes patologias que envolvem infiltração leucocitária como distúrbios inflamatórios do intestino, infecção óssea ou prótese-vasculares entre outras. A marcação dos leucócitos in vitro pode ser realizada com 111In utilizando-se oxima ou tropolona como ligante ou com 99mTc, tendo a hexametilpropileno amino oxima (HMPAO) como ligante, resultando em um complexo lipofílico. A melhor disponibilidade, menor tempo de realização do exame, melhor propriedade física e menor dose de radiação para o paciente, resultou na preferência pelo agente HMPAO marcado com 99mTc, ao invés do 111In, para a maioria das indicações na maioria dos países. Entretanto, a marcação empregando o agente HMPAO apresenta como desvantagens a curta estabilidade do reagente marcado, as exigências relacionadas ao processo de marcação (tempo pós-eluição do 99mTc), além do custo elevado, pois se trata de produto importado. Este trabalho visou o desenvolvimento do reagente liofilizado de glucoheptonatoestanho para marcação de leucócitos com 99mTc in vitro pelo método de préestanização. A otimização da técnica de marcação foi realizada através da incubação dos leucócitos, isolados de sangue total, com diferentes volumes do reagente de glucoheptonato-estanho por diferentes tempos à 37°C (préestanização), com posterior marcação com 99mTc (185 MBq), incubados à temperatura ambiente por 20 minutos. O rendimento da marcação foi superior a 90% na condição ótima de marcação. O reagente liofilizado mostrou-se estável por mais de 90 dias. As imagens cintilográficas obtidas 1, 2 e 3 horas após a administração dos leucócitos radiomarcados em coelho New Zeland demonstraram a alta eficiência de marcação de processo inflamatório provocado a partir da administração local de terebentina. O método de marcação de leucócitos desenvolvido apresenta aplicação promissora na clínica médica, com proposta de redução de custo do procedimento, apesar de ser um procedimento mais demorado quando comparado ao procedimento que utiliza o quelante lipofílico de HMPAO. / The study and localization of inflammatory and infection process in Nuclear Medicine represents a relevant tool in diagnostic procedures. In same cases, the diagnostic is easy and based on anamnesis and clinical observation; in other cases, the patients are asymptomatic or present non specific symptoms that difficult the diagnostic. The early diagnostic of inflammatory or infectious process allow the early introduction of therapy and prevents complications. Farther, the differentiation between inflammation and infection is of extreme importance as well as the localization of the focus. The use of labeled leucocytes, studied and applied in much pathologies, is the method of choice for the visualization of inflammation and infection. The scintigraphy using labeled leucocytes was introduced at 1976 by McAffe and Thakur and since of this is used in the diagnostic of different pathologies related to leucocyte infiltration like intestinal inflammatory disease, bone or prosthetic-vascular infections. The in vitro labeling of leucocytes with 111In was performed using oxime or tropolone as ligand and with 99mTc using hexamethylpropylene amine oxime (HMPAO) as ligand, resulting in a lipophilic complex. The 99mTc-HMPAG complex was preferably employed in many indications and countries do to the ideal physical properties of 99mTc that results in low dose to the patient. However, the labeling employing the HMPAO complex results in some disadvantages like the low stability of the complex, and some requirements related to the 99mTc elution (like the time pos elution), beyond the high cost of the compound that is imported. The aim of this work was the development of a tin-glucoheptonate lyophilized kit for in vitro leucocytes labeling with 99mTc using the pre-stannization method. The optimization of the labeling technique was developed using leucocytes isolated from total blood and employing different volumes of the tinglucoheptonate reagent and different incubation times at 37 deg C (pre-stannization), and posterior labeling with 99mTc (185 MBq), after 20 minutes reaction at room temperature. The labeling yield was superior to 90% using the optimized labeling conditions. Lyophilized reagent was stable after 90 days. Scintilographic images obtained 1, 2 e 3 hours after the administration of labeled leucocytes in New Zealand rabbit, showed good uptake on inflammatory focus promoted by tupertine injection. The leucocytes labeling method developed can be probably applied in clinical procedures and represents cost effective method in substitution of the lipophilic complex of HMPAO.
197

Uma proposta para avaliação do desempenho de câmaras PET/SPECT / A proposal for Evaluating the performance of PET/SPECT Cameras

Aoki, Suely Midori 11 December 2002 (has links)
A tomografia por emissão de pósitrons (\"Positron Emission Tomography\" - PET) é uma técnica para obtenção de imagens tomográficas em Medicina Nuclear que permite o estudo da função e do metabolismo do corpo humano em diversos problemas clínicos, através do uso de fármacos marcados por radionuclídeos emissores de pósitrons. As aplicações mais frequentes ocorrem em oncologia, neurologia e cardiologia, através da análise qualitativa e quantitativa dessas imagens. Atualmente, a PET é realizada de duas maneiras: através de sistemas constituídos por anéis formados por alguns milhares de detectores operando em coincidência, chamados de sistemas dedicados; ou com o uso de câmaras PET /SPECT, formadas por dois detectores de cintilação em coincidência, que também servem para estudos com radionuclídeos emissores de fóton único (\"Single Photon Emission Computed Tomography\" - SPECT). O desenvolvimento desses sistemas PET /SPECT tornou viáveis os estudos com a fluor-deoxiglicose, [18 ANTPOT. F]-FDG, um fármaco marcado com 18 ANTIPOT. F (emissor de pósitrons com 109 minutos de meia-vida física), para um número grande de clínicas e hospitais, principalmente por estes serem de uma tecnologia economicamente mais acessível que os realizados com a PET dedicada. Neste presente trabalho, desenvolveu-se uma metodologia para caracterizar e avaliar um sistema PET /SPECT com dois detectores de cintilação e dispositivo com duas fontes pontuais de Cs-137, destinado à obtenção das imagens de transmissão para a correção de atenuação dos fótons. Ela se baseia em adaptações dos testes convencionais de câmaras SPECT, descritos no IAEA TecDoc - 602 - 1991 (\"lnternational Atomic Energy Agency\" - IAEA), e de sistemas PET dedicados, publicados no NEMA NU 2- 1994 (\"National Electrical Manufacturers Association\"NEMA). O resultado foi organizado em forma de roteiros que foram testados em uma câmara da ADAC Laboratories/Philips, a VertexlM - Plus EPIClMJMCDlM - AC, instalada no Serviço de Radioisótopos do lnCor - HCFMUSP (Instituto do Coração - Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo). Esta câmara foi a primeira instalada no Brasil e está sendo utilizada, predominantemente, para estudos oncológicos e de viabilidade miocárdica. O radiofármaco utilizado na obtenção das imagens foi a [18F]-FDG, fornecida regularmente pelo IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares/Comissão Nacional de Energia Nuclear - São Paulo), e a reconstrução tomográfica foi realizada com o software próprio do sistema, utilizando-se os parâmetros padrão dos protocolos clínicos. Foram utilizadas fontes pontuais suspensas no ar para as medidas de resolução espacial transversal e lineares imersas na água para as de fração de espalhamento e sensibilidade. Na avaliação da sensibilidade, uniformidade, taxa de eventos verdadeiros, taxa de eventos aleatórios e tempo morto do sistema eletrônico, foram feitas imagens de um simulador físico construído especialmente para o presente trabalho, a partir das instruções da publicação NEMA NU 2 - 1994 para sistemas PET dedicados. A acurácia da correção de atenuação foi verificada através das imagens do simulador físico citado com a inserção de três cilindros de densidades diferentes: água, ar e Teflon. Os roteiros deste trabalho poderão servir de guia para Programas de Controle e Garantia de Qualidade e avaliação da performance de sistemas PET /SPECT com dois detectores de cintilação em coincidência. A implantação destes roteiros pelos centros clínicos que utilizam este tipo de equipamento aumentará a qualidade e a confiabilidade nas imagens resultantes, assim como na sua quantificação. / Positron emission tomography, PET, is a Nuclear Medicine technique that allows the study of human body\'s function and metabolism in many clinical problems, with the help of pharmaceuticals labeled with positron emitters. The most frequent applications occur in oncology, neurology and cardiology, through qualitative and quantitative analysis of these images. Currently, PET is performed in two manners: by using dedicated systems, consisted of rings of thousands of detectors operating in coincidence; or with the use of PET /SPECT cameras, formed by two scintillation detectors in coincidence, which are also used in SPECT studies (single photon emission tomography). The development of PET /SPECT systems made possible the studies with fluor-deoxiglucose, [18F]-FDG, a pharmaceutical labeled with 18F (positron emitter with 109 minutes physical half-life), for a large number of clinics and hospitals, mainly due to their economical accessibility when compared to the dedicated PET studies. In this present work, a method was developed for characterizing and evaluating a PET /SPECT system with two scintillation detectors and device with two point sources of 137Cs, designed to obtain the transmission images for the photon attenuation correction. lt is based on adaptations of the conventional tests of SPECT cameras, described in IAEA TecDoc - 602 - 1991 (\"international Atomic Energy Agency \" - IAEA), and those for dedicated PET systems, published in NEMA NU 2 - 1994 (\"National Electrical Manufacturers Association \" - NEMA). The results were organized in a set of testing protocols and tested in the ADAC Laboratories/Philips camera, the VertexlM - Plus EPIClM/MCDlM - AC, installed in the Radioisotopes Service of lnCor - HCFMUSP (Instituto do Coração - Hospital das clínicas da Faculdade de Medicina da Universidade de São Paulo). This camera was the first one installed in Brazil and is being used, predominantly, for oncological studies and miocardial viability. The radiopharmaceutical used was [18F]-FDG, supplied regularly by IPEN/CNEN-SP (Instituto de Pesquisas Energéticas e Nucleares I Comissão Nacional de Energia Nuclear - São Paulo), and the tomographic reconstruction was performed with the system software, using the standard parameters of the clinical protocols. Point sources suspended in air were used in the measurements of spatial resolution and linear sources immersed in water for scattering fraction and sensitivity measurements. In the evaluation of sensitivity, uniformity, true events, random events and dead time of the electronic system, a phantom was constructed specifically for the present work, from the instructions of NEMA NU 2 - 1994 for dedicated PET systems. The accuracy of the attenuation correction was verified from the images of the phantom with three inserts of different densities: water, air and Teflon. The resultant protocols can serve as a guideline for Programs of Quality Control and Assurance, as well as for the evaluation of the performance of PET /SPECT systems with two scintillation detectors in coincidence. lf implemented by clinical centers that use this type of equipment, it will enhance the quality and confidence of the resulting images, as well as their quantification.
198

Avaliação do perfil dos resíduos de serviços de saúde de Belo Horizonte quanto à presença de rejeitos radioativos na destinação final / Evaluation of the waste profile from (medical) health services of Belo Horizonte concerned to the presence of radioactive wastes in the disposal system

Adirson Monteiro de Castro 15 March 2005 (has links)
Nenhuma / Os procedimentos médicos de diagnóstico e tratamento que utilizam radiofármacos geram rejeitos radioativos que, após decaírem até o limite de eliminação, podem ser destinados pelas vias convencionais de coleta e disposição final de Resíduos Sólidos Urbanos RSU. O objetivo da pesquisa foi detectar radiometricamente a presença de rejeitos radioativos nos resíduos de serviços de saúde destinados à disposição final. Ressalta-se que o limite legal de eliminação para rejeitos sólidos estabelecido pela Comissão Nacional de Energia Nuclear CNEN é de 7,5 x 104 Bq/kg (2 Ci/kg). As medições foram feitas no conteúdo de 25 caminhões da coleta especial de Resíduos de Serviços de Saúde (RSS), no aterro sanitário de Belo Horizonte, utilizando-se um cintilômetro de iodeto de sódio. Em 60% dos casos foram encontrados valores acima do limite estabelecido. A análise espectral de 6 amostras revelou a presença do radionuclídeo tecnécio-99m (99mTc), em 5 delas, e de eodo-131 (131I), em um caso. Estes elementos, tecnécio-99m (99mTc) e iodo-131 (131I), são os mais utilizados em procedimentos de Medicina Nuclear. Conclui-se que está havendo liberação de rejeito radioativo com os de Resíduos de Serviços de Saúde (RSS), devido a inobservância do tempo de decaimento até obtenção dos níveis legalmente permitidos para liberação. / The medical procedures of diagnosis and treatment that use radiopharmaceuticals generate radioactive wastes that can, after reaching the release limit, follow the conventional ways of collection and disposal of the urban solid wastes. This research aims to detect radiometrically the presence of radioactive wastes in the health-care wastes at the final disposal. It is pointed out that the legal limit for the release of solid wastes established by Brazilian National Commission of Nuclear Energy (CNEN) is 7,5x104 Bq/kg (2 Ci/kg). Measurements in the material of the garbage trucks that make the special collect from Health Service installations are performed, at Belo Horizonte sanitary landfill, using a NaI scintillation counter. Values above the established limit were found in 60% of the cases. The spectral analysis of 6 samples showed the presence of 99mTc in 5 of them and 131I in one. These radionuclides are the most common radionuclides used in Nuclear Medicine. In conclusion there are radioactive wastes released together with the health service wastes, due to the disregard of the decay time until the legal limit is achieved.
199

DOSE GLANDULAR E CONTROLE DE QUALIDADE DA IMAGEM EM SERVIÇOS DE MAMOGRAFIA COM SISTEMA DE RADIOGRAFIA COMPUTADORIZADA / GLANDULAR DOSE AND IMAGE QUALITY CONTROL IN MAMMOGRAPHY FACILITIES WITH COMPUTED RADIOGRAPHY SYSTEM

Marcelino Vicente de Almeida Dantas 05 March 2010 (has links)
O câncer de mama é o câncer mais comum entre as mulheres, e a detecção precoce é crucial para seu diagnóstico e tratamento. Atualmente, o método mais efetivo para a detecção precoce do câncer de mama é a mamografia, onde o sistema tela/filme é o padrão ouro. Entretanto, apesar do sistema tela/filme ter sido melhorado e otimizado ao longo dos anos, para imagens da mama, existem algumas limitações críticas, incluindo faixa de exposição, artefatos da imagem, problemas no processamento dos filmes, e inflexibilidade em processamento das imagens e gerenciamento dos filmes. Nos últimos anos, a mamografia digital tem sido introduzida nos programas de rastreamento do câncer, com o sistema tela/filme sendo gradualmente substituído. A radiografia computadorizada (computed radiography - CR), comumente conhecida também como photostimulable phosphor (PSP) ou storage phosphor, emprega placas de imagem reutilizáveis e computadores e programas associados para adquirir e mostrar as radiografias de projeção digital. Neste trabalho foi testado um modelo de protocolo para a realização do controle de qualidade de imagem e de avaliação de doses glandular em 19 instituições com sistemas de radiografia computadorizada em mamografia. O protocolo foi validado através de testes feitos no Laboratório de Radioproteção Aplicada à Mamografia (LARAM) do Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). A avaliação visual da qualidade da imagem do phantom CDMAM mostrou que 53% dos serviços conseguiram produzir imagens de ótima qualidade. Já a avaliação automatizada da qualidade da imagem, através do software de análise cdcom.exe, mostrou que 57% das imagens eram de boa qualidade. O teste da linearidade do detector mostrou que a resposta do sistema CR é bastante linear, onde 95% dos serviços / Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratório de Radioproteção Aplicada à Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test.
200

Desenvolvimento de metodologia para avaliação automatizada da qualidade de imagens digitalizadas em mamografia / Development of methodology for assessment of image quality in mammography digitized

Priscila do Carmo Santana 04 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O processo de avaliação da qualidade de imagens radiográficas em geral, e de mamografia em especial, pode ser muito mais preciso, prático e rápido com o auxílio de ferramentas de análise computacional. A proposta deste trabalho é o desenvolvimento de uma metodologia computacional para automatizar o processo de avaliação da qualidade das imagens mamográficas por meio de técnicas de processamento digital de imagens (PDI), utilizando um ambiente de processamento de imagens já existente (ImageJ). Com a aplicação de técnicas de PDI foi possível determinar características geométricas e radiométricas das imagens avaliadas. Os parâmetros avaliados incluem resolução espacial, detalhes de alto contraste, limiar de baixo contraste, detalhes lineares de baixo contraste, massas tumorais, índice de contraste e densidade óptica de fundo. Os resultados obtidos por esta metodologia foram comparados com os resultados apresentados nas avaliações visuais realizadas pela Vigilância Sanitária de Minas Gerais. Por meio desta comparação foi possível demonstrar que esta metodologia automatizada apresenta-se como uma promissora alternativa para redução ou supressão da subjetividade existente na metodologia de avaliação visual, atualmente em uso. / The process of evaluating the quality of radiographic images in general, and mammography in particular, can be much more accurate, practical and fast with the help of computer analysis tools. The purpose of this study is to develop a computational methodology to automate the process of assessing the quality of mammography images through techniques of digital imaging processing (PDI), using an existing image processing environment (ImageJ). With the application of PDI techniques was possible to extract geometric and radiometric characteristics of the images evaluated. The evaluated parameters include spatial resolution, high-contrast detail, low contrast threshold, linear detail of low contrast, tumor masses, contrast ratio and background optical density. The results obtained by this method were compared with the results presented in the visual evaluations performed by the Health Surveillance of Minas Gerais. Through this comparison was possible to demonstrate that the automated methodology is presented as a promising alternative for the reduction or elimination of existing subjectivity in the visual assessment methodology currently in use.

Page generated in 0.0471 seconds