Methods for improving quality and efficiency in quantitative echocardiography : Aspects of using high frame rate

Aase, Svein January 2008 (has links)
Ultralyd er i dag et standardverktøy innen hjertediagnostikk. Analyse av ventrikkelfunksjon gjøres subjektivt ved å se på gråskala ultralydopptak av hjertet. Dette gjør dokumentasjon og opplæring vanskelig. Det er derfor ønskelig med kvantitative mål på ventrikkelfunksjon. Kvantitative metoder kan benytte høy tidsoppløsning og dermed også registrere flere detaljer. To teknikker for kvantitativ ventrikkelanalyse er vevs-Doppler og speckle tracking (mønsterfølging). Ved bruk av disse teknikkene er det viktig å sikre kvaliteten av resultatene samtidig som analyseprosessen kan gjennomføres så effektivt som mulig. I denne avhandlingen presenteres flere metoder for å sikre kvalitet og øke effektivitet ved kvantitativ ventrikkelanalyse som alle er relatert til bruk av høy tidsoppløsning. For å kunne gjøre effektiv ventrikkelanalyse behøves analyseverktøy. Et slikt verktøy som fungerer med både vevs-Doppler og speckle tracking presenteres i denne avhandlingen. Dette verktøyet har gjort flere store kliniske studier mulig. Ved analyse av hendelsene som skjer innen en hjertesykel er det viktig å dele opp hjertesykelen i ulike faser. Venstre ventrikkels tømmingsfase avsluttes ved at aortaklaffen lukkes, og denne hendelsen må derfor bestemmes før kvantitative parametre i slutten av tømmingsfasen og i overgangen til fyllingsfasen kan bestemmes. I denne avhandlingen vurderes og testes ulike kandidater for bestemmelse av lukkingen. To gunstige kandidater i hastighetskurver fra basale deler av ventrikkelen ble funnet: andre nullkryssing etter tømming og høyeste positive akselerasjon etter tømming før fylling. Et eget bidrag viser at den siste av disse kan bestemmes automatisk. For å oppnå høy tidsoppløsning kreves høy datarate. En populær metode for å øke datarate er flere parallelle mottaksstråler for hver sendestråle. I vanlig gråtoneavbilding av hjertet er det imidlertid observert at dette medfører uønskede linjelignende strukturer i bildet. I denne avhandlingen vises det at årsaken til dette er at de parallelle strålene deformeres når de passerer strukturene mellom hjertet og proben. Avhandlingen inneholder også et bidrag som viser hvordan bruk av parallelle mottakstråler kan medføre at vevs-Doppler kurver blir hentet fra et annet sted i hjertet enn det intensjonen var. Samlet er avhandlingen et bidrag til fortsatt utvikling og forbedring av kvantitative ultralydmetoder innen hjertediagnostikk.
32

Medical device innovation : the integrated processes of invention, diffusion and deployment /

Roback, Kerstin January 2006 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2006. / Härtill 4 uppsatser.
33

En reliabilitets- och validitetsstudie av en blickregistreringsutrustning

Wahlund, Ellinor January 2005 (has links)
<p>Arbetets syfte var att utreda reliabilitet och validitet för en blickregistreringsutrustning, JAZZ™, som finns på FOI i Linköping. Dessutom skulle utredningen klargöra huruvida utrustningen kan användas till att detektera mental arbetsbelastning. Tre olika studier gjordes på 17 försökspersoner. Endast sackader i horisontalled studerades, trots att utrustningen har ett flertal andra mätområden. Första studien utredde utrustningens reliabilitet och validitet, om JAZZ™ mätte det som avsågs (i det här fallet sackader i horisontalled) samt om mätningarna var konsekventa från ett försökstillfälle till ett annat. Den andra och tredje studien behandlade mental arbetsbelastning. Även subjektiva bedömningar togs med i utredningen då försökspersonerna fick svara på en enkät efter varje genomfört försök. Statistiska resultat visade bland annat signifikanta skillnader mellan de olika studierna och inga signifikanta skillnader mellan de inbördes försöken, vilket indikerar att JAZZ™-utrustningen är reliabel och valid. Tillsammans med de subjektiva bedömningarna kan det också påvisas att utrustningen kan detektera mental arbetsbelastning.</p>
34

En jämförelse mellan svenska mammografer med film-skärm system och nivåer satta av europeiska kommissionen

Durke, Anna, Lindfors, Lina January 2005 (has links)
<p>För att ta reda på hur svenska mammografiavdelningar står sig mot det europeiska protokollet undersöks nio mammografiavdelningar. Till hjälp har ett CDMAM-fantom version 3.4 och fyra plexiglasskivor använts för att simulera ett normaltjockt bröst. Även ljusskåpen och filmens egenskaper har undersökts och jämförts med kraven i europeiska protokollet. Avgränsningar har gjorts då koncentreringen ligger på mammografer som använder sig av film-skärm system.</p><p>Röntgenbilderna har studerats utan tekniska hjälpmedel. Efter bedömning och poängsättning av bilderna på CDMAM-fantomet har värdena förts in i ett Excel-program där värdena presenteras i grafer. Från graferna utvärderas om bildkvaliteten ligger inom</p><p>gränserna som anges för bra bildkvalitet. Det är endast ett av sjukhusen som ligger inom gränsen för bra bildkvalitet.</p><p>Jämförelser har gjorts för att undersöka hur filmens egenskaper påverkar bildkvaliteten och om stråldosen har betydelse för bildkvaliteten. Samma sjukhus som har den högsta stråldosen har också den bästa bildkvaliteten.</p>
35

Causes of multimodality of efficiency gain distributions in accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling

Deniz, Daniel January 2009 (has links)
<p>Fixed-collision correlated sampling for Monte Carlo (MC) simulations is a method which can be used in order to shorten the simulation time for brachytherapy treatment planning in a 3D patient geometry. The increased efficiency compared to conventional MC simulation is measured by efficiency gain. However, a previous study showed that, in some cases, PDFs (probability density functions) of estimates of the efficiency gain, simulated using resampling and other MC methods, were multimodal with values below 1. This means that the method was less effective than conventional sampling for these cases. The aims of this thesis were to trace the causes of the multimodal distributions and to propose techniques to mitigate the problem caused by photons with high statistical weights.Two simulation environments were used for the study case, a homogeneous and a heterogeneous environment. The homogenous environment consisted of a water sphere with the radius 100mm. For the heterogeneous environment a cylindrical block of tungsten alloy (diameter 15 mm, height 2.5 mm) was placed in the water sphere. The sphere was divided into an array of cubic voxels of size 2.5 mm x 2.5 mm x 2.5 mm for dose calculations. A photon source was positioned in the middle of the water sphere and emitted photons with the energy 400 keV.It was found that the low values and multimodal PDFs for the efficiency gain estimates originated from photons depositing high values of energy in some voxels in the heterogeneous environment. The high energy deposits were due to extremely high statistical weights of photons interacting repeatedly in the highly attenuating tungsten cylinder. When photon histories contributing to the rare events of high energy deposits (outliers) were removed, the PDFs became uni-modal and efficiency gain increased. However, removing outliers will cause results to be biased calling for other techniques to handle the problem with high statistical weights.One way to resolve the problem in the current implementation of the fixed-collision correlated sampling scheme in PTRAN (the MC code used) could be to split photons with high statistical weights into several photons with the same sum weight as the initial photon. The splitting of photons will result in more time consuming simulations in areas with high attenuation coefficients, which may not be the areas of interest. This could be resolved by using Russian roulette, eliminating some of the photons with high statistical weight in such areas.Fixed-collision correlated sampling for Monte Carlo (MC) simulations is a method which can be used in order to shorten the simulation time for brachytherapy treatment planning in a 3D patient geometry. The increased efficiency compared to conventional MC simulation is measured by efficiency gain. However, a previous study showed that, in some cases, PDFs (probability density functions) of estimates of the efficiency gain, simulated using resampling and other MC methods, were multimodal with values below 1. This means that the method was less effective than conventional sampling for these cases. The aims of this thesis were to trace the causes of the multimodal distributions and to propose techniques to mitigate the problem caused by photons with high statistical weights.Two simulation environments were used for the study case, a homogeneous and a heterogeneous environment. The homogenous environment consisted of a water sphere with the radius 100mm. For the heterogeneous environment a cylindrical block of tungsten alloy (diameter 15 mm, height 2.5 mm) was placed in the water sphere. The sphere was divided into an array of cubic voxels of size 2.5 mm x 2.5 mm x 2.5 mm for dose calculations. A photon source was positioned in the middle of the water sphere and emitted photons with the energy 400 keV.It was found that the low values and multimodal PDFs for the efficiency gain estimates originated from photons depositing high values of energy in some voxels in the heterogeneous environment. The high energy deposits were due to extremely high statistical weights of photons interacting repeatedly in the highly attenuating tungsten cylinder. When photon histories contributing to the rare events of high energy deposits (outliers) were removed, the PDFs became uni-modal and efficiency gain increased. However, removing outliers will cause results to be biased calling for other techniques to handle the problem with high statistical weights.One way to resolve the problem in the current implementation of the fixed-collision correlated sampling scheme in PTRAN (the MC code used) could be to split photons with high statistical weights into several photons with the same sum weight as the initial photon. The splitting of photons will result in more time consuming simulations in areas with high attenuation coefficients, which may not be the areas of interest. This could be resolved by using Russian roulette, eliminating some of the photons with high statistical weight in such areas.</p>
36

The influence of Ca2+ and Nitroprusside on the opening kinematics of the mitral valve

Oom, Charlotte January 2006 (has links)
<p>During a cardiac cycle the cardiac walls change between contracted and relaxed and the valves open and close in response to pressure changes. This master thesis is a study of the changes in heart movement pattern caused by intravenous injections of Ca2+ or Nitroprusside. At Stanford University radiopaque markers have been surgically implanted in the walls and in the mitral valve of ovine hearts and 3D coordinates for each marker have been constantly measured during the cardiac cycle. By using MatLab, the volume and pressure of the left ventricle and several parameters related to the opening kinematics of the mitral valve have been analyzed. The results show, among others, that both Ca2+ and Nitroprusside reduce the volume and pressure of the left ventricle and that both substances decrease the size of the mitral annular ring. It was also shown that Ca2+ delays the opening of the mitral valve.</p>
37

Bildbaserad estimering av rörelse för reducering av rörelseartefakter / Image-based estimation of headmovement

Jogbäck, Mats January 2006 (has links)
<p>För att kunna rekonstruera en tredimensionell volym av en hjärna avbildad med hjälp av magnetresonanstomografi (MRI) behöver man korrigera varje snittbild i förhållande till varandra, beroende på oundvikliga rörelser hos den röntgade patienten. Detta förfarande kallas bildregistrering och idag använder man sig primärt av en metod där en bild utses till referensbild och därefter anpassas närliggande bilder, som antas ha en minimal avvikelse, till referensen.</p><p>Syftet med detta examensarbete är att använda en annan metod vanligen utnyttjad inom datorseende för att estimera ett rörelsefält utifrån en vanlig videosekvens, genom att följa markörer som indikerar rörelse. Målet är att skapa en robust estimering av huvudets rörelse, som då kan användas för att skapa en mer noggrann korrigering och därmed också en bättre rekonstruktion.</p> / <p>Before reconstructing a three dimensional volume from an MR brain imaging sequence there is a need for aligning each slice, due to unavoidable movement of the patient during the scanning. This procedure is known as image registration and the method used primarily today is based on a selected slice being the reference slice and then registrating the neighbouring slices, which are assumed to be of minimal deviation.</p><p>The purpose of this thesis is to use another method commonly used in computer vision - to estimate the motion from a regular videosequence, by tracking markers indicating movement. The aim is to create a robust estimation of the movement of the head, which in turn can be used to create a more accurate alignment and volume.</p>
38

ZigBee-teknikens möjligheter att trådlöst överföra EKG-signaler

Nguyen, Tho January 2007 (has links)
<p>In many clinical applications, it is desirable to transmit sensor information wireless. In earlier research, investigation transmit ECG signal using Bluetooth, was performed. However, when Bluetooth has some drawbacks it is of interest to investigate alternative methods, one such method is ZigBee. Bluetooth has higher data rate speed (1Mbps) than ZigBee (250kbps). However, Bluetooth consumes more power. ZigBee uses in applications where low power consumption is important compared to high data rate. For industrial purposes, ZigBee is used in sensors and control unit technology. For medical treatment ZigBee can be used for patient monitoring.</p><p>The aim of this work is to investigate if it is possible to wireless transmit an ECG signal with ZigBee-technology.</p><p>The result shows that an ECG signal can be transmitted by using ZigBee. Since ZigBee is designed for low power consumption, the Zigbee-module must be set in passive mode in most of the time.</p>
39

Utveckling inom den medicintekniska branschen : -En studie om svenska medicintekniska företags samarbetsformer

Sandås, Therese, Karlström, Micaela January 2008 (has links)
<p>Svenska medicintekniska företag kan inte konkurrera med de globala företagen med stordrift och låga priser, de måste därför anpassa sina produkter efter de specifika behoven i den svenska vården.</p><p>Syftet med studien är att analysera och utvärdera svenska medicintekniska företags marknadsföringsstrategier med avseende på sambandet mellan samarbetsformer och produkters anpassning till specifika behov.</p>
40

Finansiering av små företag i den medicintekniska branschen : En undersökning kring problematiken av ett stort kapitalbehov i introduktionsfasen

Haavisto, Ida, Rolke, Fia January 2010 (has links)
<p>Många små företag upplever svårigheter att finansiera företaget under uppstarten, det krävs både kontakter, tur och tålamod för att lyckas. Att finna finansiering är ofta ett omfattande och tidsödande arbete för småföretagaren. Medicintekniska företag tillverkar ofta forskningsbaserade produkter och har ett stort kapitalbehov långt innan de kan visa upp en färdig produkt eller försäljningsintäkter. Detta är ett stort problem då externa finansiärer helst inte vill riskera för mycket vid en investering och föredrar att investera i ett senare skede.</p><p><strong>Syfte: </strong>Syftet med uppsatsen är att ta reda på vilken attityd småföretag i medicintekniska branschen har på externt kapital samt i vilken utsträckning det används för finansiering av företagen i introduktionsfasen.</p><p><strong>Teori: </strong>Finansieringsteori och tidigare forskning kring finansiering av småföretag samt riskkapital har studerats för att skapa en teoretisk referensram.</p><p><strong>Metod: </strong>En kvalitativ metod användes och undersökningen bygger på intervjuer med åtta små medicintekniska företag, en affärsinkubator och en investerare. Vid analysen användes en deduktiv ansats och teorier och modeller testades mot det empiriska underlaget.</p><p><strong>Resultat och analys: </strong>Finansieringen under uppstarten består till största delen av offentlig finansiering och riskkapital. Företagen har en lång introduktionsfas då det tar lång tid att ta en produkt till marknad. Det förekommer gap mellan företag och investerare av olika karaktär, förväntningsgap, informationsgap och skillnad i målsättning är några. Det är relativt lätt att få de små belopp som krävs för att starta ett företag men småföretagen har sedan svårt att komma över tröskeln hos riskkapitalbolagen då de söker ett för litet kapitalbelopp.</p><p><strong>Slutsatser: </strong>Offentlig finansiering är betydande för företagen. Det stora kapitalbehovet gör det nödvändigt att finansiera företaget med riskkapital. Riskkapital bidrar förutom rent finansiellt med kompetens och kontakter. Trots att investerare helst vill investera i senare faser kan dessa företag attrahera externt kapital.</p>