• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 305
  • 5
  • 3
  • Tagged with
  • 320
  • 320
  • 164
  • 47
  • 46
  • 45
  • 37
  • 37
  • 33
  • 31
  • 28
  • 28
  • 27
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Construção de um sistema de analise automatico em fluxo monossegmentado acoplado a um forno microondas

Chagas, Ismael Pereira 31 July 2018 (has links)
Orientador : Jarbas Jose Rodrigues Rohwedder / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-31T15:14:57Z (GMT). No. of bitstreams: 1 Chagas_IsmaelPereira_M.pdf: 4597178 bytes, checksum: 6f6e726f2d535e65d27ec591976ec8bb (MD5) Previous issue date: 2001 / Mestrado
32

SECADOR DE MIN?RIOS N?O FERROSOS ? MICRO-ONDAS ALTERNATIVA PARA REDU??O DE UMIDADE DE CAULIM E BENTONITA EXPLORADAS NA PARA?BA

Lima, Jonatas Micael 12 June 2018 (has links)
Submitted by Programa de P?s-Gradua??o Engenharia El?trica (ppgee@ifpb.edu.br) on 2018-06-12T12:45:28Z No. of bitstreams: 1 48- J?natas Micael Vieira de Lima - SECADOR DE MIN?RIOS N?O FERROSOS ? MICRO-ONDAS ALTERNATIVA PARA REDU??O DE UMIDADE DE CAULIM E BENTONITA EXPLORADAS NA PARA?BA.pdf: 6695678 bytes, checksum: f00e3e39064445f7a21411f1d528665e (MD5) / Approved for entry into archive by Programa de P?s-Gradua??o Engenharia El?trica (ppgee@ifpb.edu.br) on 2018-06-12T12:47:03Z (GMT) No. of bitstreams: 1 48- J?natas Micael Vieira de Lima - SECADOR DE MIN?RIOS N?O FERROSOS ? MICRO-ONDAS ALTERNATIVA PARA REDU??O DE UMIDADE DE CAULIM E BENTONITA EXPLORADAS NA PARA?BA.pdf: 6695678 bytes, checksum: f00e3e39064445f7a21411f1d528665e (MD5) / Made available in DSpace on 2018-06-12T12:47:03Z (GMT). No. of bitstreams: 1 48- J?natas Micael Vieira de Lima - SECADOR DE MIN?RIOS N?O FERROSOS ? MICRO-ONDAS ALTERNATIVA PARA REDU??O DE UMIDADE DE CAULIM E BENTONITA EXPLORADAS NA PARA?BA.pdf: 6695678 bytes, checksum: f00e3e39064445f7a21411f1d528665e (MD5) Previous issue date: 2018-06-12 / Este estudo apresenta uma proposta de melhoria no processo de beneficiamento de min?rios n?o ferrosos como o caulim e bentonita explorados no estado da Para?ba, mais especificamente a etapa de secagem. O processo de secagem adotado hoje nas mineradoras ? extremamente prejudicial ao meio ambiente, tendo em vista que s?o utilizados fornos ? lenha para redu??o de umidade. Dessa forma, visando principalmente reduzir o impacto ambiental, este trabalho apresenta um estudo de viabilidade do ponto de vista energ?tico e econ?mico do uso da secagem utilizando ondas eletromagn?ticas na faixa de micro-ondas, alimentados a partir de uma planta de gera??o com pain?is fotovoltaicos, avaliando dados e realizando medi??es para subsidiar o projeto de um forno secador de min?rio assistido por micro-ondas. Os resultados mostram que n?o apenas ? poss?vel realizar a secagem, como tamb?m o uso de forno de micro-ondas no processo traz diversos benef?cios tais como velocidade, efici?ncia, seguran?a, controle sobre o processo e redu??o dos impactos ambientais.
33

Estudo e aplicação das micro-ondas acopladas ao processo oxidativo avançado Fenton na degradação do corante tartrazina / Study and application of microwave coupled to Fenton advanced process in the degradation of tartrazine

Natália Sabes Sabatini 27 June 2014 (has links)
Esta dissertação teve como objetivo estudar o acoplamento das micro-ondas ao processo Fenton para o tratamento de uma solução de um corante azóico, tartrazina, 300 mg L-1. Para isso, foi realizado um planejamento fatorial 24 para a determinação dos efeitos dos fatores quantitativos: pH, concentração (razão) de Fe2+/H2O2 e vazão; e do uso das micro-ondas como fator qualitativo, sobre o tratamento. A variável-resposta utilizada foi a porcentagem de descoramento obtida pela área sob o espectro de absorção na região do visível (400 a 700 nm). Os resultados indicaram que o único fator estatisticamente significativo foi o pH. A partir dessa informação, outras avaliações foram realizadas a fim de se reforçar o resultado obtido. Realizaram-se análises de mineralização, ecotoxicidade e cromatografia liquida de alta eficiência, nas melhores condições de tratamento a fim de se comparar os processos Fenton e Fenton acoplado às micro-ondas: [Fe2+] = 1,2 mmol L-1, [H2O2] = 12 mmol L-1, pH 6 e tempo de reação de 25 min. Não foram observadas diferenças significativas de mineralização entre os processos Fenton e Fenton acoplado às micro-ondas, assim como na cromatografia liquida de alta eficiência e na ecotoxicidade. Em condições intermediárias utilizadas no planejamento experimental [Fe2+] = 1,0 mmol L-1, [H2O2] = 10 mmol L-1 e pH 7, variou-se a potência do forno de micro-ondas de 244,2 a 628,0 W e o tempo de residência de 7 a 90 s. Também não houve diferença significativa, tanto no desempenho de descoramento quanto na mineralização. Usando-se uma lâmpada de descarga sem eletrodo por 25 min após a reação de Fenton, mais uma vez não houve diferença significativa entre os processos Fenton e foto-Fenton. Conclui-se, portanto, que dentro da faixa estudada as micro-ondas não interferiram no processo. / This thesis aimed at studying the coupling of microwaves to the Fenton process for the treatment of an azo dye solution, tartrazine, 300 mg L-1. For that, a 24 factorial design was performed to determine the effects of the quantitative factors: pH, Fe2+/ H2O2 concentration (ratio) and flow rate; and the use of microwaves as a quali-tative factor on the treatment. The response-variable was the percentage of color removal obtained by the area under the visible absorption spectra (400 to 700 nm). The results indicated pH as the sole statistically significant factor. Further investiga-tions were performed in order to corroborate the previous result. Mineralization, eco-toxicity, and high performance liquid chromatography analyses were performed with the best treatment conditions in order to compare the Fenton process with the one coupled to microwaves: [Fe2+] = 1.2 mmol L-1, [H2O2] = 12 mmol L-1, pH 6, and reac-tion time of 25 min . No significant differences were observed in mineralization by both processes, as well as in high performance liquid chromatography and ecotoxici-ty analyses. With other conditions also used in the factorial design, [Fe2+] = 1.0 mmol L-1, [H2O2] = 10 mmol L-1, and pH 7, the microwave oven power (244.2 to 628.0 W) and residence time (7 to 90 s). No significant differences, both in color removal and in mineralization were noriced. By using a discharge electrodeless lamp for 25 min after the Fenton reaction, once again no significant difference between Fenton and photo-Fenton processes were noticed. Therefore, it can be concluded that, within the studied range, the microwaves did not interfere in the process.
34

Desenvolvimento e caracterização de material composito a base de PMMA reforçado com fibra de vidro para uso odontologico / Development and characterization of stuff composite to based on PMMA reinforced with fiberglass for use odontologic

Paiva, Vanessa Giusti 10 September 2008 (has links)
Orientadores: Wagner dos Santos Oliveira, Leila Peres / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-12T08:56:57Z (GMT). No. of bitstreams: 1 Paiva_VanessaGiusti_M.pdf: 3847622 bytes, checksum: 3b220ff7426435a8efb069e376425300 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste trabalho foi avaliar a resistência mecânica e a morfologia de fratura de resinas acrílicas sem e com reforço, processadas por microondas. Foram confeccionados 20 cp, sendo eles, Sem Reforço (SR), P246 5%, P246 8%, FSR 5%, FSR 8%, 688 5%, 688 8%, M14P 5% e M14P 8%, medindo 65 x 10 x 2,5mm, sendo os cp SR o grupo controle e os outros com os reforços de filamentos de fibra de vidro e microfibra de vidro. Utilizou-se para confecção das formulações estudadas a resina Vipi Wave, preparadas numa potência de 20 minutos/180W e 5 minutos/450W. Para as análises mecânicas foram feitas análises de variância e teste de Tukey, p<0,05. Constatou-se um aumento significativo para todos os cp reforçados submetidos aos ensaios de resistência à flexão e ao módulo de elasticidade, destacando-se os reforços (P246 5%, P246 8%, 688 5% e 688 8%). Para a análise da dureza (Esquerda, Central e Direita) e para resistência ao impacto não foi observada diferença estatística significante entre o grupo controle e os demais cp reforçados. Para a análise morfológica microestrutural da fratura foram utilizados fragmentos resultantes dos testes de impacto. Verificou-se uma melhor adesão entre a matriz polimérica e os reforços (P246 5%, P246 8%, 688 5% e 688 8%). Comparando-se os resultados dos ensaios mecânicos e a análise morfológica, concluiu-se que os reforços (P246 5%, P246 8%, 688 5% e 688 8%) apresentaram os melhores resultados, p<0,05. Mesmo não sendo observada uma melhora na adesão entre os reforços (FSR 5% e FSR 8%) e a matriz polimérica, estes apresentaram resultados estatisticamente significantes, p<0,05, em relação aos ensaios de resistência à flexão e ao módulo de elasticidade. / Abstract: The purpose of the present study is to evaluate the mechanical resistance and the fracture morphology of acrylic resins reinforced with glass fiber filaments and glass microfiber. 20 proof bodies (PB) were produced from each group, namely, no reinforcement (NR - control), P246 5%, P246 8%, FSR 5%, FSR 8%, 688 5%, 688 8%, M14P 5% and M14P 8%, measuring 65 x 10 x 2,5mm. These were made of a Vipi Wave microwave polymerized resin. Potencies employed were 20 minutes/180W and 5 minutes/450W. In order to perform the mechanical analysis, variation analysis and Tukey test p<0,05 were used. It was evidenced a significant improvement for all cp reinforcements submitted for flexion resistance analysis and the elasticity module analysis, evidencing the reinforcements (P246 5%, P246 8%, 688 5% e 688 8%). For the hardness tests (Left, Right and Center) and for impact. it was not observed significant differences between the control group and the reinforced PBs. For microstructure morphology characterization were used fragments origned from impact tests. Through this technique, it was evidenced some positive interaction between the polymeric matrix and the reinforced PBs. Comparing the results of the mechanic analysis and morphologic analysis, is was concluded that that reinforcements (P246 5%,P246 8%, 688 5% e 688 8%) presented the best results, p<0,05. Even that a better adhesion was not observed between reinforcement (FSR 5% e FSR 8%) and polymeric matrix, these presented significant improvements results, p<0,05, in relation to flexion resistance analysis and elasticity module analysis. / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
35

Aplicação de microondas no processo de beneficiamento da castanha do Brasil (Bertholletia excelsa)

Silva, Flavio Alves da 06 December 2002 (has links)
Orientador: Antonio Marsaioli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-01T15:05:55Z (GMT). No. of bitstreams: 1 Silva_FlavioAlvesda_M.pdf: 20533920 bytes, checksum: ba7969efbb3ec968e16e1bd5844887c1 (MD5) Previous issue date: 2002 / Resumo: A castanha do Brasil (Bertholletia excelsa Humb. & Bonpl.) oriunda da região Amazônica, durante toda sua trajetória comercial, softe ação depredatória. O clima e o grau pluviométrico na época da safta são fatores que favorecem a penetração de insetos, parasitas e microrganismos, provocando a deterioração total ou parcial da amêndoa. Outra dificuldade que ocorre no beneficiamento da castanha é durante a secagem do produto, pois esta etapa não oferece garantias quando as condições de armazenamento e transporte dos produtos se não forem adequadas, havendo o risco de se reumedecerem. O objetivo primário deste projeto foi o de avaliar o desempenho de um sistema piloto de secagem assistido a microondas combinado com aplicação de ar quente na secagem de amêndoas de castanha do Brasil, comparando-o com os processos convencionais. Outro objetivo foi o de estudar a preservação da amêndoa seca, armazenada durante seis meses. Foi também elaborado, de forma complementar, um estudo econômico preliminar destes processos alternativos. A operação do sistema piloto foi otimizada a partir de diferentes combinações de potências de microondas e tempos de residência, com as demais variáveis - umidade, temperatura e velocidade do ar - fixadas. Seu desempenho operacional foi avaliado e comparado com os dos secadores a ar quente convencionais. A qualidade da amêndoa seca foi monitorada através de determinações de atividade de água, índice de estabilidade oxidativa, assim como determinações de índice de peróxido. Com os resultados obtidos foi possível confirmar a viabilidade técnica deste sistema piloto e estimar preliminarmente a viabilidade econômica da sua eventual aplicação em escala industrial. / Abstract: The Brazil nut (Bertholletia exce/sa Humb. & Bonpl.) native to the Amazonian region, suffers depredatory action during the whole of its commercial pathway. The climate and pluviometric rate at the time of harvest are factors that favor the penetration of insects, parasites and microrganismos, leading to the total or partial deterioration of the nut. Another difficulty that occurs in the processing of the chestnut is the drying of the product, this stage not guaranteeing quality when the conditions of storage and transport of the products are not adequate, with the risk of remoistening occurring. The primary objective of this project was to evaluate the performance of a pilot drying system assisted by microwaves combined with the application of hot air, in the drying of Brazil nuts, comparing this process with the conventional one. Another objective was to study the preservation of the dry nut during six months storage. A preliminary economic study of these altemative processes is also presented. The operation of the pilot system was optimized using different combinations of microwave power and residence times, with the following fixed variables: moisture content, temperature and air speed. The operational performance was evaluated and compared with that of conventionalhot air driers. The quality of the dry nut was monitored by the determination of its water activity, oxidative stability and peroxide value. With these results it was possible to confirm the technical viability of this pilot system and to estimate, in a preliminary form, the economic viability of its eventual applicationon industrial scale. / Mestrado / Mestre em Engenharia de Alimentos
36

Movimentação dental linear em protese total superior em função dos materiais de inclusão e metodos de polimerização

Boscato, Noeli 02 August 2018 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:35:31Z (GMT). No. of bitstreams: 1 Boscato_Noeli_M.pdf: 1495029 bytes, checksum: c863e45b8ffda144f65c6b53a089e4e9 (MD5) Previous issue date: 2002 / Mestrado
37

Preparação de fases estacionarias para cromatografia liquida da alta eficiencia (CLAE) a partir de silica titanizada e polibutadieno

Morais, Lais Sayuri Ribeiro de 03 August 2018 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T17:31:25Z (GMT). No. of bitstreams: 1 Morais_LaisSayuriRibeirode_M.pdf: 2716061 bytes, checksum: f02e9247f86da3e9d9a06d99b69a252b (MD5) Previous issue date: 2003 / Mestrado
38

Avaliação da adaptação e porosidade de bases de protese, segundo diferentes tipos de resfriamento

Ganzarolli, Solimar Maria 25 March 1999 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T09:43:13Z (GMT). No. of bitstreams: 1 Ganzarolli_SolimarMaria_M.pdf: 8627151 bytes, checksum: c3d5f90a3acf2ab8334bd573c19f4a36 (MD5) Previous issue date: 1999 / Resumo: A adaptação das bases de prótese evita a formação de hiperplasias, e mantém uma adequada função mastigatória. A presença de porosidade pode levar à um acúmulo de Cândida albicans, e diminuição da resistência da prótese. Foi propósito deste trabalho avaliar a adaptação e porosidade de 72 bases de prótese, confeccionadas com resina acrílica termopolimerizável convencional Clássico e resinas para polimerização em forno de microondas, Acron-MC e Onda Cryl, quando submetidas ao procedimento de resfriamento brusco, e convencional das mesmas após polimerizadas. A avaliação foi realizada imediatamente após a demuflagem e após um período de armazenagem por 30 dias. Os métodos utilizados para verificação da desadaptação foram: a) Peso de silicona de adição (Express-3M) interposto entre a base de resina e o modelo metálico. b) Medida da desadaptação entre o interior da base de resina e a superfície do modelo de gesso, em 09 pontos diferentes do rebordo. A porosidade foi avaliada pelo peso de cada amostra, em balança de precisão de 0,001g. Os resultados obtidos foram submetidos a ANOV A, e verificou-se com o teste de Tuckey que o resfriamento convencional permitiu a melhor adaptação das bases de prótese e os procedimentos de resfriamento brusco não interferiram na porosidade da resina / Abstract: Good adaptation of denture bases avoids hyperplasic formations and provides an adequate masticatory function. Porosity can lead to microorganisms growing, Cândida albicans, and decrease of denture base strength. The aim of this study was to evaluate the adaptation and porosity of 72 denture base made with Clássico conventional heat-cured acrylics resins and microwave-activated resins, Acron-MC and Onda Cryl, when submited to bench cooling. Adaptation assessment was performed immediately after deflasking and after 30 days storage period. The methods used were: a) Weight measured of addition silicon (Express-3M) liner between the denture base and the metallic model; b) microscopic linear measurement between the inner part of the denture base and the plaster cast model, in 9 different points on the residual ridge and palate. Porosity was evaluated by weight of each silicon base acrylic resin using a precision scales with 0,001g accuracy. Data were analyzed with ANOVA and Tuckey's test. Conventional cooling technique presented the best denture base adaptation and the fast cooling procedure did not have influence in resin porosity / Mestrado / Protese / Mestre em Clínica Odontológica
39

[en] STUDY OF THE PROPAGATION CARACTERISTICS OF PLANAR STRUCTURES USING THE METHOD OF LINES / [pt] ESTUDO DAS CARACTERÍSTICAS DE PROPAGAÇÃO EM ESTRUTURAS PLANARES UTILIZANDO O MÉTODO DAS LINHAS

ANTONIO MANOEL FERREIRA FRASSON 04 May 2007 (has links)
[pt] O objetivo deste trabalho é apresentar o método das linhas aplicado ao estudo das características de propagação em estruturas planares. Na sua aplicação, discretiza-se variáveis especiais em um conjunto de linhas perpendiculares as fitas. Conseqüentemente, equações diferenciais parciais são reduzidas a equações diferenciais ordinárias com soluções bem conhecidas. Apesar da aplicação de diferenças finitas, o Método das Linhas é mais eficiente em termos de velocidade computacional e uso de memória, quando comparado com método de diferenças finitas usual. Algumas estruturas planares em guias retangulares com três camadas dielétricas foram analisadas e os resultados comparados com outros métodos. Nos apêndices mostra-se como é possível implementar programas com discretização não uniforme, o que aumenta a eficiência do método, bem como a discretização em duas direções, o que permite análise de ressoadores de microondas. Este trabalho pretende servir como auxilio básico, podendo ser útil em outros trabalhos empregando o Método das Linhas. / [en] In this work, the Method of Lines applied to the study of the propagation caracteristics of planar structures is presented. In this method, the spacial variables are discretized in several lines orientated in a direction normal to the conductor strips. Then, the partial differential equations are reduced to ordinary differential equations having well known solutions. Although this method uses finite differences, it is much more efficient with respect to computer speed and memory necessary, in comparison to the conventional finite difference method. A few planar structures with three dieletric layers, inside rectangular waveguides were analysed, and the results are compared with those using other reported methods. In the appendix, it is shown how to develop computer programs using non-uniform discretization for the improvement of the efficiency of this method. Also, the discretization in two directions is presented, which is adequate for analysis of microwave resonators. This work is intended as a basic approach to hel in further analysis using the Method of Lines.
40

Movimentação linear de dentes em protese total superior processada pela tecnica de caracterização intrinseca, sob influencia de dois metodos de polimerização

Almeida, Marco Antônio Borges de 19 May 2003 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T16:12:10Z (GMT). No. of bitstreams: 1 Almeida_MarcoAntonioBorgesde_D.pdf: 3316387 bytes, checksum: 4a317591e4fe3a13b286e2e0eac92827 (MD5) Previous issue date: 2003 / Resumo: o objetivo deste estudo foi verificar a movimentação linear dos dentes em prótese total superior, confeccionada com resina acrílica ativada termicamente, processada pela técnica de caracterização intrínseca, sob a influência de dois métodos de polimerização: água aquecida e energia de microondas. A partir da duplicação de uma prótese total superior confeccionou-se 30 conjuntos idênticos de modelo de gessolbase-de-provaldentes artificiais. Estes conjuntos foram separados aleatoriamente em três grupos experimentais, sendo submetidos aos seguintes tratamentos: G1- processamento de caracterização intrínseca com polimerização em microondas; G2- processamento convencional com polimerização em água aqueci da (controle); G3- processamento de caracterização intrínseca com polimerização em água aquecida. A movimentação linear dos dentes foi mensurada em sete distâncias em cada prótese, em dois estágios de sua confecção: antes da inclusão e após polimerização, acabamento, polimento e armazenagem em água destilada à temperatura de 37°C :t 2°C por 30 dias. Todas as mensuraçóes foram realizadas por um mesmo operador em microscópio comparador linear (Olympus), com precisão de 0,0005mm. Os dados obtidos e submetidos ao teste de Kruskal-Wallis em nível de 5% de significância permitiram concluir que: A movimentação linear dos dentes artificiais, nos grupos processados pela técnica de caracterização intrínseca em ambos os métodos de polimerização investigados, não apresentou diferença estatística significativa para a maioria das distâncias avaliadas; A escolha da técnica de processamento a ser empregada deve ser baseada em critérios individuais e particulares que considerem o domínio da técnica de processamento empregada, o tempo de confecção despedido e o resultado estético a ser alcançado; A correta execução dos procedimentos técnicos e laboratoriais durante as etapas de confecção das próteses totais deve prevalecer à escolha deste ou daquele ciclo de polimerização, técnica de processamento ou marca comercial de resina / Abstract: The aim of this study was to verify the linear teeth movement in maxillary denture made with heat-cured acrylic resin, processed by technique of intrinsic characterization, under influence of two methods of polymerization heat-water and microwave energy. Thirty identical maxillary dentures were obtained and randomly assigned in 3 groups in order to receive the following treatments: Group 1- intrinsic characterization processing and microwave polymerization; Group 2- conventional processing and heat-water polymerization; Group 3- intrinsic characterization processing and heat-water polymerization. Seven individual measurements were taken on each denture at two specific stages in the construction of denture: before investment and after polymerization, finishing, polishing procedures and storage in the water at 37°C :f: 2°C for 30 days. Measurements were made by a single operator with a linear comparator microscope (Olympus), with accuracy of 0,OOO5mm. Data were analyzed with Kruskal-Wallis test at 5% of significance and showed that: The linear movement of artificial teeth, in the groups processed for the technique of intrinsic characterization in both the investigated methods of polymerization, was without difference significant statistics for the majority of the evaluated distances; The choice of the technique of processing must be based on individual and particular criteria that consider the domain of the processing technique used, the time consumed and the aesthetic result to be reached; The correct execution of the technical procedures and laboratorial stages of construction of the dentures must prevail to the choice of this or that cycle of polymerization, technique of processing or commercial resin brand / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.0452 seconds