• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 4
  • 1
  • Tagged with
  • 147
  • 128
  • 29
  • 28
  • 26
  • 22
  • 20
  • 20
  • 19
  • 18
  • 17
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação in vitro do potencial do laser de CO2, associado ou não a produtos fluoretados, em inibir erosão em esmalte dental humano / In vitro evaluation of the potential of CO2 laser associated or not to fluorides in inhibiting human enamel erosion

Thayanne Monteiro Ramos-Oliveira 06 July 2012 (has links)
Considerando a eficácia limitada do flúor na proteção dos tecidos duros dentais contra a erosão, o objetivo do presente estudo foi investigar o potencial do laser de gás carbônico (CO2) (10,6 m), associado ou não a produtos fluoretados, na inibição da erosão de esmalte dental. Amostras de esmalte dental humano foram obtidas e divididas aleatoriamente em 8 grupos (n = 11): G1: controle (sem tratamento), G2: gel de Flúor Fosfato Acidulado (FFA), G3: gel de fluoreto de sódio (AmF/NaF), G4: solução de fluoreto estanhoso (AmF/SnF2), G5: laser de CO2 (0,3 J/cm2, 15 s, 226 Hz), G6: laser de CO2 + gel de FFA, G7: laser de CO2 + gel de AmF/NaF e G8: laser de CO2 + solução de AmF/SnF2. Após os tratamentos de superfície, as amostras foram imersas em ácido cítrico a 1% (pH 4,0, 3 minutos). Antes dos tratamentos de superfície e após o desafio ácido, a microdureza de superfície foi mensurada (0,49 N, 20 segundos) e os dados foram analisados estatisticamente através do teste ANOVA com subseqüentes comparações entre pares (p < 0,05). Os resultados mostraram que o grupo G3 (403,5 ± 25,0) apresentou a maior média de microdureza Knoop após o desafio ácido, seguido pelos grupos G2 (396,6 ± 45,0) e G6 (392,8 ± 24,9), sem diferença estatística entre eles. Dentre os grupos tratados com produtos fluoretados, o grupo G4 (305,5 ± 17,7) resultou em microdureza significativamente mais baixa que o G3 (403,5 ± 25,0) e o G2 (396,6 ± 45,0), os quais foram estatisticamente semelhantes entre si. Dentre os grupos tratados com laser, os grupos G5 (341,1 ± 23,8), G7 (374,9 ± 42,1) e G8 (328,6 ± 26,9) apresentaram valores de dureza estatisticamente semelhantes entre si. Dentro dos limites do presente estudo in vitro, pôde-se concluir que o tratamento com gel de AmF/NaF e gel de FFA (com ou sem irradiação prévia com o laser de CO2) mostrou potencial para controlar a progressão da erosão no esmalte dental humano. / Considering the limited effectiveness of fluoride in protecting dental hard tissues against erosion, the aim of the present study was to investigate the potential of the CO2 laser (10.6 m) associated to fluoride agents in inhibiting human enamel erosion. Human enamel samples were obtained and randomly divided into 8 groups (n = 11): G1: control (no treatment), G2: APF gel, G3: AmF/NaF gel, G4: AmF/SnF2 solution, G5: CO2 laser (0.3 J/cm2, 15 s, 226 Hz), G6: CO2 laser + APF gel, G7: CO2 laser + AmF/NaF gel and G8: CO2 laser + AmF/SnF2 solution. After surface treatment, samples were immersed in 1% citric acid (pH 4.0, 3 min). Knoop Surface microhardness (SMH) (0.49 N, 20 s) was measured before surface treatments and after surface softening. The data were statistically analyzed by ANOVA model with subsequent pairwise comparisons (p < 0,05). Group G3 (403.5 ± 25.0) presented the highest SMH means after softening, followed by Groups G2 (396.6 ± 45.0) and G6 (392.8 ± 24.9) with no statistically significant difference between them. Between the fluoride-treated groups, G4 (305.5 ± 17.7) resulted in significantly low SMH mean than G3 (403.5 ± 25.0) and G2 (396.6 ± 45.0), which were statistically similar to each other. Between the laser-treated groups, G5 (341.1 ± 23.8), G7 (374.9 ± 42.1) and G8 (328.6 ± 26.9) presented SMH means statistically similar to each other. Within the limits of the present in vitro study, AmF/NaF and APF application (with or without previous CO2 laser irradiation) have shown a potential to control erosion progression in human dental enamel.
62

Efeito do tratamento de superfície e do nível de reaproveitamento sobre as propriedades mecânicas de um sistema cerâmico prensado / Effect of the surface treatment and repressing level on the mechanical properties of a pressable ceramic system

Alexandra Tavares Andrade 26 August 2010 (has links)
Objetivo: Verificar a influência do nível de reaproveitamento e do tratamento de superfície sobre a resistência à flexão e microdureza Vickers de um sistema cerâmico prensado. Material e métodos: Foram utilizados sessenta corpos-de-prova do sistema cerâmico prensado IPS e.max (Ivoclar-Vivadent). Os corpos-de-prova (25X4X1,2mm) foram confeccionados seguindo a especificação ISO 6872, de acordo com o nível de reaproveitamento da cerâmica: GI 100% nova, GII 50% nova + 50% reaproveitada, GIII - 100% reaproveitada, GIV GI + ácido hidrofluorídrico, GV GII + ácido hidrofluorídrico e GVI GIII + ácido hidrofluorídrico. Foi realizado o teste de resistência à flexão de três pontos (n=10), conforme especificação ISO 10477 e ISO 6872. A microdureza Vickers foi mensurada em cinco corpos-de-prova de cada grupo, sob carga de quinhentos gramas por dez segundos. Os resultados foram submetidos ao teste de normalidade e posteriormente a ANOVA e post-hoc teste de Tukey, com nível de significância de 5%. Resultados: Os valores médios de microdureza variaram de 436,90 (GIV) a 605,97 (GII). Não foram observadas diferenças quanto ao nível de reaproveitamento, e o ácido reduziu estatísticamente os valores de dureza, para todos os grupos em estudo. Os valores médios de resistência a flexão variaram de 455,70 (GIV) a 500,56 (GIII). Não foram observadas diferenças estatísticas entre os grupos avaliados quanto ao nível de reaproveitamento e aplicação do ácido hidrofluorídrico. Conclusões: O reaproveitamento, total ou parcial, não exerceu influência sobre as propriedades mecânicas avaliadas. O condicionamento com ácido reduziu estatísticamente os valores de dureza, sem efeito sobre os resultados de resistência à flexão. / Objective: the aim of the present study was to observe the influence of the repressing level of ceramic and of the surface treatment on the flexural strength and Vickers microhardness of a pressable ceramic system. Material and methods: Sixty samples of a pressable ceramic system (IPS e.max - Ivoclar- Vivadent) were confectioned, with dimensions of 25X4X1.2mm, following specification ISO 6872, according to the level of repressing: GI - 100% new ceramic, GII - 50% new + 50% repressed, GIII - 100% repressed, GIV - GI + etching using hydrofluoric acid, GV - GII + etching using hydrofluoric acid and GVI - GIII + etching using hydrofluoric acid. Flexural strength test was accomplished by a three-point test, according to specification ISO 10477 and ISO 6872. Vickers microhardness was measured in five samples to each group, under load of five hundred grams for ten seconds. Results were submitted to ANOVA and Tukey post-hoc test, with level of significance of 5%. Results: Mean values of microhardness ranged between 436,90 (GIV) and 605,97 (GII). Statistical differences were not observed for the repressing level, but etching using hydrofluoric acid reduced statistically the mean values of hardness, for all groups. Mean values of flexural strength varied from 455,70 (GIV) to 500,56 (GIII). Statistical differences were not observed among the tested groups for repressing level and etching using hydrofluoric acid. Conclusions: Repressing the ceramic, totally or partially, did not influence the evaluated mechanical properties. Etching using hydrofluoric acid reduced statistically hardness values, with no effect on the flexural strength mean values.
63

âPROPRIEDADES MECÃNICAS E CARACTERIZAÃÃO MICROESTRUTURAL NA SOLDAGEM DO AÃO INOXIDÃVEL DUPLEX UNS S31803 (SAF 2205)â / Mechanical properties and microstructural characterization in the welding of the duplex stainless steel UNS S31803 (SAF 2205)

Everton Barbosa Nunes 20 October 2009 (has links)
AgÃncia Nacional do PetrÃleo / FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Os aÃos inoxidÃveis duplex possuem boas propriedades mecÃnicas e excelente resistÃncia à corrosÃo, aumentando seu uso em ambientes agressivos. Estas caracterÃsticas os fazem muito utilizados principalmente na indÃstria quÃmica e petroquÃmica. Geralmente, a fabricaÃÃo e reparo destes equipamentos envolvem operaÃÃes de soldagem, sendo que à muito importante avaliar a influÃncia dos parÃmetros de soldagem multipasse no balanceamento de fases, na microestrutura e microdureza. Primeiramente, foram realizadas soldagens em aÃo ASTM A516 Gr. 60 com eletrodo revestido AWS 2209-17, empregando diversas energias, variando a velocidade e corrente de soldagem. Foi feita a caracterizaÃÃo microestrutural atravÃs de microscopia Ãptica, quantificaÃÃo do teor de ferrita utilizando ferritoscÃpio e ensaio de microdureza para avaliar o metal de solda. Posteriormente, foram selecionadas as melhores condiÃÃes da etapa anterior para soldagem do aÃo inoxidÃvel duplex UNS S31803 para avaliar o efeito da energia de soldagem no balanceamento de fases, na microestrutura e microdureza no metal de solda e ZAC. Na Ãltima etapa foram realizadas soldagens em juntas de aÃo duplex, de modo a avaliar o efeito da energia de soldagem e restriÃÃo da junta no balanceamento de fases, microestrutura, microdureza e tenacidade do metal de solda e da ZAC. Foi verificada a influÃncia da energia de soldagem no teor de ferrita, possuindo comportamentos diferentes de acordo com os parÃmetros de soldagem. As microestruturas bÃsicas da austenita formada foram alotrimÃrfica, WidmanstÃtten e intragranular. Nas regiÃes com sobreposiÃÃo de passe houve maior quantidade de austenita no metal de solda e microestrutura mais refinada na ZAC. Foi observado que quanto maior a velocidade de soldagem, maior a quantidade de WidmanstÃtten. De forma geral, foi observado menor nÃvel de microdureza no metal de solda, principalmente nas condiÃÃes com maior quantidade de austenita WidmanstÃtten. A restriÃÃo da junta soldada influenciou no balanceamento de fases e na tenacidade da ZAC. NÃo houve efeito da energia de soldagem na tenacidade do metal de solda, possuindo nÃveis menores em relaÃÃo ao material como recebido / Duplex stainless steels show good mechanical properties and excellent corrosion resistance. These qualities are increasing their use in aggressive environments. Thus, these characteristics make them very used in chemical and petrochemical, mainly. Generally, the manufacture and repair of any industrial equipment involve welding operations, even though it is very important to evaluate the influence of multipass welding parameters in phase balances, microstructure and microhardness. Firstly, the shielded metal arc welding in steel ASTN A516 Gr. 60 with electrode AWS 2209-17 had been carried through with many energies, varying welding speed and current. Microstructural characterization by optic microscopy, quantification of ferrite content using ferritscope and microhardness test has being performed to evaluate the weld metal. After that, the best conditions of the last stage for welding of duplex stainless steel UNS S31803 had been chosen to evaluate the effect of the welding energy in phase balances, microstructure, and microhardness in the weld metal and HAZ. In the last stage, the weldings in joint of duplex steel had been carried through, in order to evaluate the effect of the welding energy and restriction of joint in phase balances, microstructure, microhardness and toughness of the weld metal and HAZ. The influence of the welding energy in the ferrite content was checked, although the behavior was different according to variation of the welding parameters. The basic microstructures of formed austenitic were allotriomoph, WidmanstÃtten and intragranular. Regions with pass overlapping presented greater amount of austenite in the weld metal and microstructure more refined in the HAZ. It was observed that increasing welding speed, greater is the amount of WidmanstÃtten austenite. In general, the increase of the amount of WidmanstÃtten austenite decreases level of microhardness in the weld metal. The restriction of the welded joint influenced in phase balances and toughness of the HAZ. There was not effect of the welding energy on toughness of the weld metal and this region occurred higher levels in relation to material as received
64

"InfluÃncia dos protocolos de fotoativaÃÃo na microdureza e no grau de conversÃo de uma resina composta" / "Influence of curing protocols on microhardness and degree of conversion of a composite resin"

AndrÃa GalvÃo Marinho Bomfim 02 October 2009 (has links)
FundaÃÃo de Amparo à Pesquisa do Estado do Cearà / O objetivo deste trabalho foi avaliar in vitro o grau de conversÃo da resina composta Filtek Z 350 (3M ESPE), na cor A3, empregando a luz halÃgena pelo aparelho VIP (Variable Intensity Polymerizer) JÃnior (Bisco), utilizando trÃs protocolos de fotoativaÃÃo, a saber: convencional 500mW/cm por 40s; gradual 300mW/cm por 3s e, em seguida, 500mW/cm por 30s; pulso tardio 300mW/cm por 3s, com pausa de 3 min; e 300mW/cm por 30s. O grau de conversÃo da resina foi obtido atravÃs do teste de microdureza Knoop e espectrografia Raman. Uma matriz metÃlica, bipartida, com orifÃcio central de 2,5mm de profundidade e 5mm de diÃmetro, foi utilizada para confecÃÃo dos corpos de prova, que foram fotoativados segundo os protocolos descritos. Foram confeccionados cinco corpos de prova de cada tipo de protocolo para o ensaio de microdureza e uma amostra de cada protocolo para o teste de Raman. Os testes foram realizados 24 horas apÃs a polimerizaÃÃo dos corpos de prova, que foram armazenados a seco, ao abrigo da luz e à temperatura ambiente. Na microdureza, cinco indentaÃÃes foram realizadas em cada superfÃcie (topo e base) do corpo de prova com uma carga de 10gf por 10s. O Raman foi realizado no centro da amostra do topo e da base. Os resultados obtidos foram submetidos à AnÃlise de VariÃncia a 2 critÃrios e ao teste de comparaÃÃes mÃltiplas de Student-Newman-Keuls, a um nÃvel de significÃncia de 5%. Pode-se observar que houve diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo utilizados, quando a anÃlise foi realizada no topo dos espÃcimes, sendo que a fotoativaÃÃo convencional apresentou os maiores valores de dureza. Entretanto, quando a mensuraÃÃo da dureza foi realizada na extremidade oposta dos espÃcimes (base), nÃo foram observadas diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo. Contudo, nas comparaÃÃes entre os valores de dureza observados em relaÃÃo à localizaÃÃo da mensuraÃÃo (topo ou base), pode-se observar que os valores obtidos no topo dos espÃcimes foram estatisticamente superiores aos observados na base dos mesmos, com exceÃÃo do protocolo pulso tardio, onde nÃo houve diferenÃa estatÃsticamente significante ente as superfÃcies do topo e da base. O teste de Raman confirmou os resultados achados na microdureza, com o grau de conversÃo da resina, sendo maior nas superfÃcies de topo e com maior conversÃo dos protocolos convencional e soft start. / This study evaluate the degree of conversion of composite resin Filtek Z 350 (3M ESPE), on shade A3, using halogen light VIP (Variable Intensity Polymerizer) Junior (Bisco) utilizing three light curing protocols, they are: standard 500mW/cm by 40 sec; soft start 300mW/cm by 3 sec and after 500mW/cm by 30 sec; pulse delay 300mW/cm by 3 sec, stop by 3 min and 100mW/cm by 30 sec. The degree of conversion of the resin was analyzed by the test of microhardness Knoop and Raman spectrography. Five samples of each type of protocol for the microhardness test had been confectioned and one sample of each protocol for the test of Raman. The tests had been made 24 hours after the polymerization of the samples, that had been stored the dry one, protected from the light and at room temperature. In the microhardness, five indentations had been made in each surface (top and bottom) of the sample with a load of 10gf for 10s. The Raman was obtained from the center of the sample of the top and the bottom surfaces. The results had been submitted the Two-Way ANOVA and to the test of multiple comparisons of Student-Newman-Keuls, to a level of significance of 5%. It can be observed that it had statistical significant differences between the used curing protocols when the analysis was made in the top of specimens, being that the standard curing protocol presented biggest values of hardness. However, when the value of the hardness was obtained from in the opposing extremity of specimens (bottom), statistical significant differences between the curing protocols had not been observed. In the comparisons between the values of hardness observed in relation to the localization of the indentation, it can be observed independently that the values obtained in the top of specimens had been statistical differences, with exception for the protocol pulse delay, where had not significant statistical difference between the surfaces of top and bottom. The test of Raman confirmed the results finds in the microhardness, with the degree of conversion of resin higher in top surface, and with bigger degree of conversion of the conventional and soft start protocols.
65

Dispositivos LED para polimerização de resinas compostas dentais: comparação com outras fontes de luz. / LED source for dental composite photo activation.

Igor Studart Medeiros 18 December 2001 (has links)
Muito se tem feito para a melhoria das resinas compostas polimerizadas através de luz visível. A maioria dos estudos restringe-se apenas às fontes de luz convencionais e pouco tem sido feito no sentido de viabilizar novas fontes, introduzindo novas tecnologias nesta área do conhecimento. No intuito de desenvolver novos dispositivos de geração de luz para polimeração das resinas compostas dentais, o Grupo de Óptica tem sido um dos pioneiros mundiais no desenvolvimento e caracterização de dispositivos usando LEDs azuis. Neste trabalho, verificou-se a viabilidade de um novo dispositivo à base de LEDS azuis, excecutando-se uma análise comparativa com o aparelho de polimerização convencional e o laser de argônio. Para a validação deste novo dispositivo, executaram-se testes de microdureza Vickers em espécimes de resinas compostas de diferentes espessuras, expostos a diferentes tempos de irradiação. Foi executado o teste de análise térmica, com resolução temporal, durante o processo de exposição à luz para polimerização com finalidade de verificar a variação térmica pulpar em terceiros molares recém-extraídos. Em seguida, determinou-se a variação das propriedades de microdureza e resistência à tração diametral após a armazenagem em alguns agentes químicos encontrados na cavidade oral. Os resultados demonstram que o dispositivo à base de LEDs apresenta-se viável para polimerização de compósitos dentais, com algumas vantagens em relação a outras fontes de luz utilizadas para essa finalidade. / The improvement of composite resins polymerization through visible light has been an important research topic. The majority of the studies, however, are restricted only to the conventional light sources and little has been made to viable new sources, introducing new technologies in this area of the knowledge. In intention to develop new light sources for dental composite resins polymerization, the Optics Groups is one of the pioneers in the development and characterization of devices, using blue LEDs for this purpose. In this work, it was verified the viability of a new device based in blue LEDs, executing a comparative analysis with the conventional polymerization device and the argon laser. It was executed the test of thermal analysis during the process of exposure to the polymerization light, to verify the thermal variation in the pulpal chambers of third molars caries free. After that, it was determined the variation of microhardness and diametral tensile strength properties when composite specimens were storaged in chemical agents found in the oral cavity. The results have demonstrated that the LEDs based device present is viable for polymerization of dental composites with some advantages in relation to other used light sources.
66

Avaliação do processo de desenvolvimento de desmineralização em esmalte dental humano utilizando a técnica de tomografia por coerência óptica / Human dental enamel demineralization process assessment using the optical coherence tomography technique

Ana Claudia Ballet de Cara 20 August 2012 (has links)
A detecção de lesões cariosas nos estágios iniciais possibilita a escolha de tratamentos baseados na preservação da estrutura dental. Dessa forma, a utilização de exames capazes de diagnosticar precocemente essas lesões, como a Tomografia por Coerência Óptica (OCT Optical Coherence Tomography) é adequada. Assim, o objetivo do trabalho foi avaliar a capacidade da OCT em quantificar os estágios de desmineralização do esmalte durante o desenvolvimento de lesões simuladas de cárie, tendo como padrão de referência o teste de microdureza seccional. Foram utilizados 53 dentes terceiros molares hígidos, os quais tiveram as coroas seccionadas para obtenção de 210 amostras. Para avaliar as possíveis alterações sofridas por cada amostra, essas foram examinadas através da técnica de OCT no início do experimento e novamente examinadas após o término do período de ciclagem estabelecido para cada grupo, utilizando os coeficientes de atenuação óptica total e o cálculo de área em gráficos de intensidade de sinal de OCT, como parâmetros de análise. Posteriormente, as amostras foram submetidas a testes de microdureza seccional. A diferença entre os coeficientes de atenuação óptica obtidos antes e depois da ciclagem de pH apresentou elevado grau de correlação com os resultados de microdureza seccional. Por meio da análise das áreas provenientes de gráficos de intensidade de sinal de OCT e microdureza Knoop, ambos em função da profundidade, foi observada relação de linearidade entre os resultados e elevada correlação entre as técnicas avaliadas (&rho; = 0,99). De acordo com os resultados, a técnica de OCT foi capaz de detectar diferentes graus de desmineralização do esmalte dental humano em lesões simuladas de cárie. / The detection of carious lesions in early stages enables treatment choose based on dental structure preservation. This way, the utilization of exams capable of early diagnosis of these lesions, like OCT (Optical Coherence Tomography), is appropriate. Therefore, the objective of this work was to assess the capability of OCT in quantifying the enamel demineralization stages during the development of simulated caries lesions, having as reference standard the sectional microhardness test. There were used 53 sound third molars, which had their crowns sectioned to obtain 210 samples. To assess possible changes in each sample, these were examined by the OCT technique in the beginning of the experiment and again in the end of the cycling period established to each group, using the total optical attenuation coefficient and the area calculations using OCT signal intensity as analysis parameters. After that, the samples were submitted to sectional microhardness test. The difference between optical attenuation coefficients taken before and after the pH cycling, showed a high level of correlation with the microhardness results. Through areas analysis of OCT signal intensity and Knoop microhardness against depth, it was observed linearity relation between results and high correlation among assessed techniques (&rho;=0,99). According to the results, the OCT technique was capable of detecting different degrees of demineralization of the human enamel in carious simulated lesions.
67

Avaliação do efeito de diferentes agentes quelantes e desmineralizantes sobre a microdureza da dentina radicular / Evaluation of the effect of different chelating agents and demineralizing on the microhardness of root dentin.

Josilaine Amaral Pimenta 17 October 2011 (has links)
O presente estudo teve como objetivo avaliar a ação das soluções de quitosana, EDTA e ácido cítrico sobre a microdureza da dentina radicular. Utilizaram-se 10 incisivos centrais superiores humanos, os quais tiveram suas coroas seccionadas transversalmente e desprezadas. As raízes foram incluídas em resina acrílica de rápida polimerização e o bloco formado raiz/resina adaptado a máquina de corte. Desprezou-se o primeiro corte transversal da porção cervical e dividiu-se o segundo, em quatro quadrantes. Cada quarto foi destinado à confecção do corpo de prova obtendo-se 4 espécimes para cada raiz, um para cada solução (n=10): G1- EDTA 15%; G2- ácido cítrico; G3- quitosana 0,2% e G4- controle. Os espécimes receberam 50 &mu;L da solução por 5 minutos, sendo em seguida, lavados com água deionizada. Utilizou-se um microdurômetro (dureza Knoop) com carga de 10 g durante 15 segundos. Os resultados mostraram que todas as soluções avaliadas apresentaram capacidade de reduzir a microdureza da dentina radicular de forma semelhante entre si e estatisticamente diferente a do grupo controle (p<0,01). Concluiu-se as soluções de quitosana 0,2%, EDTA 15% e ácido cítrico 10% apresentam efeito semelhante na redução da microdureza dentinária. / The aim of this study was to evaluate the action of solutions: chitosan, EDTA and citric acid on the microhardness of the root dentin. There were used 10 human maxillary central incisors which ones had their crown cross-sectioned and discarded. The roots were embedded in acrylic resin of rapid polymerization and the block formed root/resin suitable by cutting machine. Neglecting the first cross-section of the cervical portion and the second was divided in four quadrants. Each quarter was destined to the confection of the specimen and it was got 4 specimen to each root, one for each solution (n=10): G1- EDTA 15%; G2- citric acid;G3- chitosan 0,2 % and G4- control. The specimen received 50 &mu;L of the solution for 5 minutes, and following up they were washed by deionized water. It was used a microhardness (Knoop hardness) with a load of 10g during 15 seconds. The results showed that all the solutions evaluated presented a capacity to reduce the microhardness of the root dentin in a similar way between them, and statically differ from the control group (p<0,01). It was concluded that chitosan 0,2% EDTA 15% and the citric acid 10% presented a similar effect in the reduction of the dentin microhardness.
68

Avaliação da microdureza de cimentos resinosos dual utilizados na cimentação de pinos de fibra de vidro submetidos a diferentes condições de polimerização e armazenamento em água / Evaluation of the microhardness of dual cure resin cements in the luting of fiberglass posts under different conditions of cure and water storage

Marcelo Barbosa Ramos 29 April 2009 (has links)
Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1, realizou-se a fotoativação após 5 minutos. As raízes foram seccionadas longitudinalmente, para que a linha de cimento pudesse ser exposta e os testes de microdureza realizados. Após 7 dias, as médias de microdureza (± desvio padrão) foram obtidas, para os terços cervical, médio e apical, respectivamente: A1 (Panavia) - 41,25 ±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. Para os grupos armazenados em água, os valores médios de microdureza (± desvio padrão) obtidos nos 3 grupos, químico (grupo A2), fotoativado imediatamente (grupo B2) e fotoativado tardiamente (grupo C2), nos terços cervical, médio e apical, respectivamente, foram: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. Os resultados foram submetidos ao teste ANOVA a 4 critérios (cimento, modo de polimerização, armazenamento e terços), que detectou diferenças estatísticas entre os grupos, e o teste de Tukey foi aplicado para comparações individuais. Os resultados mostraram que: a fotoativação com luz halógena promoveu um aumento significativo nos valores de microdureza para o cimento Panavia; o armaz namento em água por três meses reduziu os valores de microdureza para a maioria dos grupos, sendo que o cimento o U100 apresentou menor variação de dureza quando comparado ao Panavia; os terços que receberam maior intensidade de luz halógena tiveram maior aumento de microdureza para ambos os cimentos, especialmente para o cimento Panavia. Conclui-se, portanto, que as hipóteses de nulidade propostas foram rejeitadas. / The objective of this study was to evaluate the microhardness of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray), used for fiberglass posts (Fibrekor ® - Jeneric Pentron) cementation. Chemical cure and a halogen immediate and late light cure source were compared, and the effect of storage in deionized water for three months was also evaluated. This study tested the following null hypotheses: there is no difference between the microhardness values for each dual cure resin cement, cure source type, storage time, or root thirds. Sixty bovine incisor roots 16mm long had their roots restored and then prepared for post cementation. The specimens were divided into 6 groups (n = 10), and each group was subdivided into 2 subgroups with 5 specimens for each cement. The posts were cemented according to manufacturers instructions. In group A1, the specimens were kept in a light-proof environment to ensure only a chemical cure. In group B1, the specimens were restored and subjected to immediate light curing, and in group C1, light curing was performed after 5 minutes. The roots were longitudinally sectioned to expose the cement line and perform microhardness tests. After 7 days, the average microhardness (± standard deviation) values were obtained for the cervical, medium and apical thirds, respectively: A1 (Panavia ) - 41,25±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) - 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±1,93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. For the 3 groups stored in deionized water (chemical [group A2], immediate light curing [group B2] and late light curing [group C2]), the average microhardness values (± standard deviation) obtained for the cervical, medium and apical thirds, respectively were: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. ANOVA testing was used to detect statistical differences among the 4 criteria (cements, cure mode, storage and thirds) and the Tukey test was used for individual comparisons. The results showed that the halogen light cure promoted a significant increase in microhardness values for Panavia cement; storage in water for three months reduced microhardness values for most of the groups, although U100 resulted in less microhardness variation compared to Panavia; the thirds that received a higher intensity of halogen light had a higher increase in the average values of microhardness for both cements, especially for Panavia. Therefore, the null hypotheses proposed in this work were rejected.
69

Efeito da espessura e do envelhecimento por solução ácida de diferentes resinas compostas bulk fill nas propriedades de microdureza superficial e fluorescência / Effect of resin thickness, solvent storage on the micro-hardness and fluorescence of bulk-fill resin composites

Ferreira, Lyvia Karla Cerci 10 February 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T18:13:37Z No. of bitstreams: 2 Lyvia Karla Cerci Ferreira Bertacchini.pdf: 1676300 bytes, checksum: a3dc364eb9c66a1393c6417ee5dfd749 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T18:13:37Z (GMT). No. of bitstreams: 2 Lyvia Karla Cerci Ferreira Bertacchini.pdf: 1676300 bytes, checksum: a3dc364eb9c66a1393c6417ee5dfd749 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-10 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Estado do Paraná (FA) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this research was to compare the behavior of different thicknesses of bulk fill composite resins by analyzing the microhardness at the top and bottom of specimens (SP), the effect of aging with acid solution (ethanol / water) and fluorescence evaluation. 135 SP were fabricated with thicknesses of 2, 3 and 4 mm subdivided into 5 groups (n = 27): Z35; Aura; Tetric; SureFil; Filtek Bulk Fill (FBF). Each SP was photoactivated by LED light for 20 seconds. The microhardness test was performed after 24 hours and 30 days (ethanol / water solution) on both top and bottom surfaces. Fluorescence analysis was performed with the aid of a dark chamber by three calibrators: low, medium and high. The microhardness data were submitted to the factorial ANOVA test for Repeated Measures, followed by the LSD-Fisher follow-up test. Fluorescence by the LSD-Fisher Test. After 24h the microhardness was higher at the top in the thickness of 2mm: TETRIC and FBF, 3mm: Z350, TETRIC and FBF, 4mm: Z350, AURA, TETRIC and FBF. After aging the highest values in the bottom: 2mm: TETRIC and FBF, 3mm: AURA and TETRIC, in the 4mm: AURA was significantly higher than the first average. (p <0.05). It was possible to close that the larger the thickness, the greater the difference of the microhardness between the top and bottom surfaces. With regard to fluorescence, TETRIC (BF) was the only composite resin that did not have significantly altered values with increasing thickness. Aging in ethanol / water solution increased the microhardness values of some TETRIC, FBF and AURA composite resins. / O objetivo desta pesquisa foi de comparar o comportamento de diferentes espessuras de incrementos das resinas compostas tipo bulk fill, por meio da análise da microdureza no topo e na base de corpos-de-prova (CP), efeito do envelhecimento com solução ácida (etanol/água) e a avaliação da fluorescência Foram confeccionados 135 CP com espessuras de 2, 3, e 4mm subdivididos em 5 grupos (n=27): resina Z350;Aura bulk fill (AURA); Tetric bulk fill (TETRIC); SureFil bulk fill (SDR). ; Filtek bulk fill (FBF). Cada CP foi fotoativado por aparelho de luz Led durante 20 segundos. O teste de microdureza foi realizado após 24 horas e 30 dias (solução etanol/água) tanto na superfície do topo como na base. A análise da fluorescência foi realizada com auxílio de uma câmara escura por três avaliadores calibrados como: baixa, média e alta. Os dados de microdureza foram submetidos ao teste ANOVA fatorial para Medidas Repetidas, seguido pelo teste de acompanhamento de LSD-Fisher. A fluorescência pelo teste Teste LSD-Fisher. Após 24hs a microdureza foi maior no topo na espessura de 2mm: TBF e FBF, 3mm: Z350, TBF e FBF, 4mm: Z350, ABF, TBF e FBF. Após o envelhecimento os maiores valores na base: 2mm: TBF e FBF, 3mm: ABF e TBF, na de 4mm: ABF foi significativamente maior do que a média inicial. (p<0,05). Foi possível concluir que quanto maior a espessura, maior a diferença da microdureza entre a superfície de topo e base. Com relação a fluorescência a TBF foi a única resina composta que não teve os valores alterados de forma significativa com o aumento da espessura. O envelhecimento em solução etanol/água aumentou os valores de microdureza de algumas resinas compostas TBF, FBF e ABF.
70

Influência das dimensões e do modo de fotoativação do corpo de prova sobre os testes de sorção, de solubilidade e de microdureza Knoop / Influence of the specimen dimensions and mode of photoactivation on the tests of sorption, solubility and Knoop microhardness

Luciana Maria da Silva 11 February 2011 (has links)
O presente estudo avaliou a influência das dimensões e das formas de fotoativação do corpo de prova através dos testes de sorção, de solubilidade e de microdureza Knoop. Este trabalho foi dividido em duas fases. Na primeira fase, corpos de prova de um compósito experimental medindo 15 mm de diâmetro x 1 mm de espessura foram confeccionados usando uma matriz de teflon bipartida, sendo o compósito inserido em um único incremento e, em seguida, planificado por uma tira de poliéster aderida a uma placa de vidro. Todos os grupos tiveram as mesmas dimensões, porém, foram fotopolimerizados de três maneiras diferentes: G1- Com cinco exposições de cada lado do corpo de prova, de acordo com o padrão especificado pela ISO 4049; G2- Retirando a ponta do aparelho fotoativador de forma que a luz atingisse toda a superfície do espécime e G3- Distanciando a ponta do fotopolimerizador 1,5 cm com o mesmo intuito (n=5). Anova (p<0,05) e teste de Tukey 5% para diferenciação das médias não mostraram diferenças estatísticas significativas entre os grupos para o teste de sorção (p=0,517). Os valores em g/mm3 com seus desvios padrão foram: G1=22,58±1,20; G2=23,51±0,61 e G3=22,16±1,39. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,002), de acordo com as letras sobrescritas. Os valores em g/mm3 com seus respectivos desvios padrão foram G1=0,54±0,14B; G2=0,37±0,14B e G3=1,04±0,09A. Para o teste de microdureza Knoop, a análise estatística apresentou diferenças significativas entre os grupos (p=0,003). Os valores em KHN com seus desvios padrão foram G1=78,9±2,74A; G2=69,4±4,77B e G3=67,4±4,94B. A conclusão desta primeira fase foi que a melhor forma de fotoativação foi do G1 (de acordo com a ISO), a qual apresentou menor solubilidade e a maior microdureza Knoop. A segunda fase do trabalho foi feita utilizando apenas a melhor forma de fotoativação obtida na primeira fase que foi correspondente ao G1 (ISO 4049), variando as dimensões dos corpos de prova com os tamanhos mais usados na literatura de sorção e solubilidade. Os grupos experimentais foram divididos em: (diametro x espessura) g1=15x1 mm (ISO), g2=5,8 x 0,8mm e g3=6 x 0,5 mm, confeccionados da mesma forma que os corpos de prova da primeira etapa. Os espécimes foram então submetidos ao teste de sorção, de solubilidade e de microdureza Knoop. ANOVA (p<0,05) e teste de Tukey (5%) mostraram que não houve diferenças estatisticamente significativas para o teste de sorção (p=0,915). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=22,58±1,2; g2=22,28±2,26 e g3=22,78±2,02. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,006). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=0,54±0,14B; g2=3,2±2,07A, e g3=2,16±1,06AB. O teste de microdureza Knoop não demonstrou diferenças estatisticamente significativas entre os grupos (p= 0,106). Os valores em KHN, com seus respectivos desvios padrão foram: g1=62,12±0,86; g2=64,88±4,21 e g3=66,20±2,33. Levando em consideração os diversos fatores estudados pode-se concluir que as dimensões e a forma de fotoativação preconizadas pela ISO 4049 parecem ser a melhor forma de confeccionar os corpos de prova para os testes de sorção e de solubilidade, associados ao teste de microdureza Knoop. / This study evaluated the influence of the dimensions and the light-cure mode of specimens in the tests of sorption, solubility and Knoop microhardness. This research was divided into two phases. In the first stage, disc shaped samples of an experimental composite resin (15 mm in diameter x 1 mm in thickness) were fabricated using a teflon split mold., The composite was inserted in one increment and then flattened by a polyester strip adhered to a glass plate. All groups had the same dimensions, however, were polymerized in three different ways: G1-five exposures for each side of the specimen, according to the standard specified by ISO 4049, G2-removing the tip of the curing unit and allowing light to reach all the surface of the specimen, and G3-distancing the tip of the curing unit 1.5 cm with the same intention (n=5). Anova and Tukey test (p<0.05) for the means comparisons showed no statistically significant differences among groups for the sorption test (p=0.517). The values in g/mm3 with their standard deviation were: G1 = 22.58±1.20, G2 = 23.51±0.61 and G3=22.16±1.39. The solubility test showed statistically significant differences (p=0.002), according to the superscript letters. The values in g/mm3 with their respective standard deviations were G1=0.54±0.14B, G2=0.37±0.14B and G3=1.04±0.09A. For the microhardness test, statistical analysis showed significant differences among groups (p=0.003). The KHN values with their standard deviation were: G1 = 78.9±2.74A, G2 = 69.4±4.77B and G3 = 67.4±4.94B. The conclusion of this first phase was that the best way of light-curing was G1 (according to ISO), which showed lower solubility and the higher Knoop microhardness. The second research stage was performed using only the best way of light-curing achieved in the first round, which was corresponding to Group 1 (ISO 4049), varying the dimensions of the specimens with the sizes most used in the literature of sorption and solubility. The experimental groups were divided into: (Diameter x thickness) g1=15x1 mm (ISO), g2=5.8x0.8 mm and g3=6x0.5 mm, prepared in the same way as the samples of the first phase. The specimens were then submitted to the sorption, solubility and Knoop microhardness tests. ANOVA and Tukey test (p<0.05) showed no statistically significant differences for the sorption test (p=0.915).The values in g/mm3 with their respective standard deviations were: g1=22.58±1.2; g2=22.28±2.26 and g3=22.78±2.02. The solubility test showed statistically differences among groups (p=0.006). The values in g/mm3 with their respective standard deviations were: g1 = 0.54±0.14B, g2=3.2±2.07A, and g3=2.16±1.06AB. The Knoop microhardness test showed no statistically significant differences among groups (p=0.106). The values in KHN with their respective standard deviations were: g1=62.12±0.86, g2=64.88±4.21 and g3=66.20±2.33. Taking into consideration the studied factors, it can be concluded that the size and the shape of photoactivation recommended by ISO 4049 seems to be the best way of preparing the specimens for sorption and solubility tests, associated with the Knoop microhardness test.

Page generated in 0.0517 seconds