• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • Tagged with
  • 72
  • 72
  • 72
  • 72
  • 40
  • 36
  • 35
  • 35
  • 28
  • 24
  • 22
  • 15
  • 14
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Aplicações forenses do Probe Electrospray Ionization Mass Spectrometry com filme de polipirrol / Forensic aplications of Probe Electrospray Ionization Mass Spectrometry using polypyrrole films

Bernardo, Ricardo Alves 14 July 2017 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-08-09T19:01:05Z No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-08-10T13:37:03Z (GMT) No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-08-10T13:37:03Z (GMT). No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-07-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this study, we developed a solid phase microextraction (SPME) method to extract Cocaine, Lisergic Acid Diethylamide (LSD), Methamphetamine (MA) and [3,4 – Methylenedioxymethamphetamine] (MDMA), which allowed the direct analysis by MS in a Probe Electrospray Ionization Mass Spectrometry (PESI-MS). PPy fibers were deposited on a platinum wire. These fibers were subjected to drug extraction from biological fluids employing SPME principles. After that, the coated platinum wire was positioned in front of the MS and then a high voltage (HV) was applied on it. At the same time, methanol (formic acid 0,1%) was used to assist the analytes desorption, ionization, and detection. Parameters as number of cycles in electrochemical process, pH, temperature of extraction and matrix effect were evaluated. The coated PESI-MS method presented linearity in a concentration range from the limit of quantification (LOQ) to 500 ng.L-1 (ppb). The LOQ values ranged from 2 ng.L-1 to 10 ng.L-1. The interday precision presented values from 0.8 to 9.6% with accuracy ranging from -0.6 to 13.7%. The intraday precision obtained values varied from 1.7 to 10.8% with accuracy ranging from -2.4 to 14.0%. The absolute recovery was also evaluated and presented values from 97.6 to 114.0%. The proposed method is a promising alternative to fast sampling and analysis for avoiding laborious process, and for showing precision and accuracy according to the values proposed by ANVISA. / Para este trabalho foi desenvolvido um sistema SPME para extração e análise direta de Cocaína, Dietilamida do Ácido Lisérgico (LSD), [3,4 – Metilenodioximetanfetamina] (MDMA) e Metanfetamina (MA) por espectrometria de massas (MS) em uma fonte de ionização Probe Electrospray Ionization Mass Spectrometry (PESI-MS). Fibras de polipirrol (PPy) foram eletrodepositadas em um fio de platina, essas fibras foram submetidas à extração de drogas em fluidos biológicos empregando os princípios da SPME. Após a extração, o fio de platina contendo o revestimento de PPy foi posicionado na entrada do espectrômetro de massas, uma diferença de potencial (ddp) foi aplicada ao fio e com auxílio de uma solução de metanol (0,1% de ácido fórmico), observou-se a dessorção e detecção dos analitos previamente extraídos. Parâmetros como o número de ciclos de eletrodeposição e pH de extração foram avaliados. O método se mostrou linear na faixa de concentração do LOQ a 500 ng.L-1 (ppb). Os valores de LOQ variaram de 2 ng.L-1 a 10 ng.L-1. A precisão inter-dias do método foi avaliada e mostrou valores entre 0,8 a 9,6% com exatidão de -0,6 a 13,7%. A precisão intra-dias apresentou valores de 1,7 a 10,8% com exatidão de -2,4 a 14.0%. A recuperação do método também foi avaliada e apresentou valores de 97,6 a 114,0%. O método proposto apresenta-se como alternativa promissora para rápida extração e análise direta sem a realização de procedimentos dispendiosos e laboriosos, com precisão e exatidão dentro dos parâmetros propostos pela ANVISA.
42

Microextração em fase sólida e cromatografia gasosa bidimensional abrangente = aplicações em lipidômica / Solid phase microextraction and comprehensive two-dimensional gas chromatography : applications in lipidomics

Hantao, Leandro Wang, 1986- 06 October 2011 (has links)
Orientador: Fabio Augusto / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T10:51:34Z (GMT). No. of bitstreams: 1 Hantao_LeandroWang_M.pdf: 3862279 bytes, checksum: 7d8b474b736814564a1145814b69d5e9 (MD5) Previous issue date: 2011 / Resumo: Neste trabalho foram desenvolvidas metodologias para a análise de lipídios na forma de seus ésteres metílicos de ácido graxo (FAME) em diversas matrizes. Para isso foram empregadas e otimizadas de forma multivariada técnicas de derivatização dos lipídios por transesterificação por catálise básica, seu isolamento e concentração por Microextração em Fase Sólida (SPME) e análise por Cromatografia Gasosa Bidimensional Abrangente (GCxGC). A partir do perfil de extração foi escolhida a fibra comercial com revestimento de poli(dimetilsiloxano) (PDMS) com espessura de filme de 7 mm. O tempo de extração escolhido foi de 10 min pois atingiu a condição de sistema estacionário. Os parâmetros cromatográficos, tais como a programação de temperatura do forno, período de modulação e tipo de fase estacionária das colunas utilizadas no protótipo GCxGC, foram também otimizados. Além disso, durante o progresso deste trabalho, foi desenvolvido o primeiro protótipo brasileiro de GCxGC acoplado a um Espectrômetro de Massas com Analizador Quadrupolar rápido (GCxGCxqMS). Dentre os parâmetros operacionais do qMS, foram otimizados o intervalo de varredura do analizador quadrupolar e sua frequencia de aquisição. O sistema GCxGCxqMS foi empregado para a identificação dos FAME presentes nas amostras empregadas neste estudo, através do uso das informações obtidas pelos espectros de massas obtidos das amostras, com padrões analíticos e combinando o uso de índices de retenção (LTPRI) e da estrutura cromatográfica. Neste trabalho, devido ao incremento em detectabilidade e sensibilidade, foi possível observar diversos FAME comumente não detectados por Cromatografia Gasosa Convencional (GC), como FAME de comprimento ímpar de cadeia e a presença de agrupamento metila no carbono 2 (-br2). Além disso, em virtude da baixa abrangência do banco de dados disponíveis, foi possível, e necessário, criar um banco de dados com índices de retenção para análise de lipídios. Espera-se que estas metodologias desenvolvidas e os resultados apresentados possam ser empregados como ferramenta em estudos de lipidômica e aplicações correlatas / Abstract: The aim of this project was to develop alternative methodologies for lipidomic studies and related applications. A method for the analysis of lipids in different samples such as waxes, edible oils and cheek cells was developed. The isolation and concentration of the analytes was performed by Solid Phase Microextraction (SPME) combined with Comprehensive Two-dimensional Gas Chromatography (GCxGC). Firstly, the base-catalysed transesterification of the lipids into their respective fatty acid methyl esters (FAME) was optimized according to a multivariate model. Thus, the sample prepation was optimized considering the thickness of the coating and their respective extraction profiles. The choosen commercial coating was a poly(dimethylsiloxane) (PDMS) with 7 mm film thickness, the extraction time was 10 min where stationary state conditions were achieved. Secondly, chromatographic parameters were also optimized, such as the temperature programming, modulation period, the identity of the first and second dimensional columns used in GCxGC prototype. During the current study, the first brazillian prototype of a GCxGC coupled to a mass spectrometer with a rapid quadrupolar analyzer was developed (GCxGCxqMS). Also, the scan interval and acquisition frequency of the qMS were optimized. For the identification of the analytes similarity searches for mass spectra, analytical standards and the combination retention indexes with chromatographic structuration were used. Additionally it was possible to detected and identify FAME which couldn't be detected by conventional GC such as odd numbered chain length and branched FAME. Moreover, elution pattern of a branched FAME was reported, specifically the FAME with a methyl group in the carbon 2 (-br2). Because of the restricted content of the retention indexes and mass spectra database, the construction of a database with retention indexes for lipid analysis was built. Hence the ultimate goal of the current study is to present the potencial and applicability of SPME for lipidomic studies and related applications / Mestrado / Quimica Analitica / Mestre em Química
43

Determinação de off-flavours em carne e gordura suína por GCxGC combinada a SPME / Off-flavors determination in pork meat and fat by GCxGC combined with SPME

Braga, Soraia Cristina Gonzaga Neves, 1986- 21 August 2018 (has links)
Orientador: Fabio Augusto / Dissertação ( mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-21T16:42:20Z (GMT). No. of bitstreams: 1 Braga_SoraiaCristinaGonzagaNeves_M.pdf: 1977454 bytes, checksum: fb33fc10b38aaf44e885e8b0b197c7ba (MD5) Previous issue date: 2012 / Resumo: A carne de porco é a proteina mais consumida no mundo. Para ser consumida a carne necessita de um padrão de qualidade e um dos problemas que afeta esta qualidade é o surgimento de odores desagradáveis. Estes odores, conhecidos como boar taint, são causados principalmente pela presença de androstenona e escatol em níveis maiores que 1,00 mg g e 0,25 mg g, respectivamente, em gordura suína. Os métodos existentes para determinação destes compostos são dispendiosos e não geram resultados em tempos satisfatórios para análise de rotina. Neste trabalho foi proposto um novo método para determinação de androstenona e escatol em gordura suína que se baseia na utilização de microextração em fase sólida (SPME) e cromatografia gasosa bidimensional abrangente (GC xGC). Para isso foi realizada uma otimização univariada do tipo de fibra e agente saponificante e posteriormente uma otimização multivariada, envolvendo concentração de saponificante, tempo de saponificação, temperatura e tempo de extração. O método otimizado foi validado sob os parâmetros de limites de detecção e quantificação, linearidade, precisão e exatidão. Para o escatol é possível a quantificação de amostras com quantidades menores que as detectadas sensorialmente (0,25 mg g), com precisão e exatidão, mas para a androstenona, é possível apenas detectar a presença ou não deste analito. Após todo o desenvolvimento e validação do método, este foi aplicado em sete amostras de toucinho cedidas pelo ITAL / Abstract: Pork is the must consumed protein the world. For consumpted, the meat needs a quality standard and one of the problems concerning the quality of pork meat are off-flavours. These off-flavores, called boar taint are caused by the presence of two compounds, skatole and androstenone, in levels superior to 1.00 and 0.25 mg g, respectively in pig fat. In order to determine these flavors is necessary to know the concentrations of androstenone and skatole in pig fat. There are specific methods to analyse these compounds, but they spend a lot of time and require a great number of clean-up steps process. In this work, a faster and cleaner method was proposed to determine the presence of androstenone and skatole in pig fat, based in the solid phase microextraction (SPME) and comprehensive bidimensional gas chromatography (GC xGC). A univariate optimization considering the kind of fibre coating and hydrolysis agent was performed. Later a multivariate optimization was developed to determine the concentration of hydrolysis agent, time of saponification and temperature and time of extraction. The best conditions found for the method were used for its validation. The quantification and detection limits, linearity, accuracy and precision were determined. For skatole it is possible to quantify samples at smaller quantities than those found sensorially (0.25 mg g), with precision and accuracy, but for androstenone the method only detects its presence or absence in the analyte. After all the development and validation of the method, it was implemented with seven samples of pig fat, courtesy of ITAL (Instituto de Tecnologia de Alimentos) / Mestrado / Quimica Analitica / Mestra em Química
44

Persistência de fragrância em cabelo : influência das propriedades físico-químicas e da encapsulação de óleo essencial / Persistence of fragrance in human hair : role of physicochemical properties and encapsulation of perfume oil

Pavani, Matheus, 1989- 24 August 2018 (has links)
Orientadores: Marcos José Salvador, Inés Joekes / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-24T13:48:04Z (GMT). No. of bitstreams: 1 Pavani_Matheus_M.pdf: 3408518 bytes, checksum: bdb62efa906a9a04de3a371f12ecd0f0 (MD5) Previous issue date: 2014 / Resumo: A fragrância de um produto cosmético é um aspecto importante para determinar seu desempenho. É crescente o emprego de produtos naturais, bem como de fragrâncias encapsuladas na indústria cosmética. Entretanto, há escassos estudos descrevendo o perfil de liberação de fragrâncias a partir de matrizes complexas, muito menos a partir de cabelos. Este trabalho investigou a interação de uma fragrância livre ou encapsulada em cabelos virgens caucasianos. Óleo essencial de capim-limão (Cymbopogon citratus DC. Stapf), livre ou encapsulado, foi empregado como fragrância em formulações de xampu e condicionador sem enxágue. O processo de encapsulação deu-se por meio de polimerização in situ da resina de melamina-formaldeído, variando-se parâmetros reacionais como velocidade de agitação, acidificação do meio e teor de óleo essencial. Os perfis de liberação da fragrância proveniente de mechas de cabelo, tratadas com as formulações obtidas, foram tomados ao longo do tempo (0 a 12 h), com amostragem por microextração em fase sólida (SPME) e análise por cromatografia gasosa acoplada à espectrometria de massas (CG-MS). A liberação das substâncias da fragrância na forma livre variou em função do tipo de formulação cosmética (xampú ou condicionador sem enxágue). Neste caso, a persistência delas na fibra capilar se correlacionaou com seus valores de coeficiente de partição óleo-água (logP). Micropartículas esféricas (dH = 9 ± 1 µm) e rendimento de processo de 86 % foram obtidos com decaimento lento de pH aliado a agitação vigorosa durante a reação de formação. Estas partículas promoveram liberação sustentada para os constituintes linalol e citral (12 e 2 vezes mais duradoura em relação à forma livre, respectivamente), mostrando um aumento da persistência da fragrância encapsulada quando inserida em formulação sem enxágue, e modificando as forças de interação cabelo¿fragrância / Abstract: Fragrance plays an important role in the performance of a cosmetic formulation. The use of natural products in the cosmetic industry as well as encapsulated fragrances is growing. However, there are few studies describing the release profile of fragrances from complex matrices, much less from Human hair. This work investigates the interaction of a fragrance composition (free or encapsulated) with un-treated Caucasian hair. Lemongrass essential oil (Cymbopogon citratus DC. Stapf) was employed as fragrance in rinse-off shampoo or leave-on formulations. Encapsulation was performed by in situ polymerization of melamine and formaldehyde monomers, changing reaction parameters such as stirring rate, pH decay, and essential oil content. Fragrance release profiles from the hair tresses treated with the abovementioned formulations were acquired over the time (0 to 12 h) with a solid phase microextraction (SPME) device, and analyzed by gas chromatography-mass spectrometry (GC-MS). The release of free form fragrance constituents depended on the type of cosmetic formulation (shampoo or leave-on), but its persistence on hair fiber was correlated with its oil-water partition coefficient (logP) value in both cases. Spherical microparticles (dH = 9 ± 1 µm) and 86 % yield were obtained with slow pH decay combined with vigorous stirring during the encapsulation process. Sustained release of the fragrant components linalool and citral (12 times and twice longer-lasting compared to the free form, respectively) was found, showing an increased persistence of the encapsulated fragrance when inserted in the leave-on formulation and changing perfume¿hair interaction / Mestrado / Fármacos, Medicamentos e Insumos para Saúde / Mestre em Biociências e Tecnologia de Produtos Bioativos
45

Química do sabor de cervejas: detalhes moleculares de lúpulos (Humulus lupulus) cultivados no Brasil no processo cervejeiro / Beer flavor chemistry: molecular details of Brazilian hops (Humulus lupulus) in the brewing process

Durello, Renato da Silva 12 April 2019 (has links)
Nesta pesquisa está sendo investigada, pela primeira vez, a composição química de lúpulos cultivados no Brasil para a produção de cervejas artesanais. Para isso, foram analisadas 10 amostras de lúpulos das variedades cascade, columbus, chinook e hallertauer, cultivados em diferentes regiões do Brasil (Minas Gerais, Paraná e Rio Grande do Sul). Quando foram comparadas as composições químicas dos lúpulos cultivados no Brasil com lúpulos comerciais produzidos em outros países, verificou-se que o lúpulo da variedade cascade produzido em Araxá - MG era o que apresentava maior similaridade ao produto comercial. O cascade nacional apresentou teores de humulonas e lupulonas de 4% e 3%, respectivamente. Quanto aos teores de óleo essencial, o cascade nacional apresentou um rendimento de 1,2 % (v/m). Os principais constituintes do óleo essencial deste lúpulo foram: mirceno (59%), 2-metilbutil isobutirato (0,7%), linalol (0,5%), β-cariofileno (4%), α-humuleno (15%) e α-farneseno (1%). Após esta triagem, o lúpulo cascade nacional foi utilizado para fabricação de uma cerveja artesanal, sendo que, em paralelo foi também fabricada uma cerveja artesanal com o lúpulo cascade comercial (controle), a fim de comparar o efeito da origem do lúpulo na composição química de voláteis e iso-humulonas nas cervejas produzidas. Além disso, também está sendo investigado o efeito da adição de uma enzima beta-glicosidase na liberação de terpenos provenientes do lúpulo nas cervejas fabricadas com o lúpulo cultivado no Brasil e com o lúpulo comercial. Para análise dos voláteis da cerveja foi otimizada, por metodologia de superfície de resposta, a etapa de extração dos voláteis empregando micro-extração em fase sólida de headspace (HS-SPME). As condições ótimas de extração foram: fibra CAR/DVB/PDMS, temperatura de extração de 75 °C por 121 minutos. As cervejas produzidas apresentaram diferenças na composição dos seus voláteis, e no aroma avaliado em uma degustação as cegas. Aquelas cervejas elaboradas com enzima apresentaram aromas mais intensos que as elaboradas sem enzima β-glicosidase, o que pode ser explicado pela maior quantidade de certos terpenos nestas cervejas, o que sugere a existência de terpenos glicosilados nos lúpulos empregados. Quanto aos teores de iso-humulonas nas cervejas, embora estes compostos foram quantificados nas quatro cervejas elaboradas, não foi possível comparar os resultados por um possível erro na etapa de lupulagem durante a elaboração das cervejas. / In this research the chemical composition of cascade, columbus, chinook and hallertauer hops, cultivated in different regions of Brazil (Minas Gerais, Paraná and Rio Grande do Sul) are being investigated for chemical composition for the first time. When comparing the chemical compositions of Brazilian hops with commercial hops produced in other countries, it was verified that the cascade variety produced in Araxá city (MG) were the most similar to the commercial products. The cascade cultivated in Brazil presented levels of humulones and lupulones of 4% and 3%, respectively. Regarding the essential oil contents, cascade cultivated in Brazil showed a yield of 1.2% (v/w). The main constituents of the essential oil of this hop were: β-mycene (59%), 2-methylbutyl isobutyrate (0.7%), linalool (0.5%), β-caryophyllene (4%), α-humulene and α-farnesene (1%). After this sceening, the cascade cultivated in Brazil were used to make a craft beer, and in parallel was also made a craft beer with commercial cascade hop (control), in order to compare the effect of hops origin on volatiles chemical composition and on iso-humulones content in the beers produced. In addition, the effect of β-glucosidase, an enzyme which catalyses the hydrolysis of terminal non-reducing residues in β-glucosidese (EC number: 3.2.1.21), on the release of hop volatiles (from glicoside terpenes) to beers is also being investigated. For the beer volatile analysis, the extraction step by headspace solid phase microextraction (HS-SPME) was optimized by response surface methodology. The optimal extraction conditions were: CAR/DVB/PDMS fiber, and extraction temperature of 75 °C for 121 minutes. The beers produced showed differences in the composition of their volatiles, and in the aroma evaluated in a blind sensory test. The beers made with enzyme showed more intense aromas than those made without β-glucosidase, which can be explained by the greater amount of certain terpenes in these beers, which suggests the existence of glycosylated terpenes in the hops. Regarding the iso-humulone levels in the beers, although these compounds were quantified in the elaborated beers, it was not possible to compare the results by a possible error in the hopping stage during brewing.
46

Determinação de canabinóides em cabelo por microextração em fase sólida por Headspace e análise por espectrometria de massa associada à cromatografia em fase gasosa / Determination of cannabinoids in hair by Headspace solid-phase microextraction and gas chromatography-mass spectrometry

Oliveira, Carolina Dizioli Rodrigues de 21 July 2005 (has links)
Foi desenvolvido um método para determinar canabinóides (canabidiol, canabinol e delta-9-tetraidrocanabinol) no cabelo. Uma amostra de 10mg foi descontaminada com diclorometano, seguida de digestão alcalina, microextração em fase sólida por headspace (HS-SPME) e analisada por espectrometria de massa associada à cromatografia em fase gasosa (GC/MS). Os limites de detecção e de quantificação foram de 0,07 e 0,12 ng/mg, respectivamente, para todos canabinóides estudados. O método demonstrou ser simples, rápido, preciso e linear no intervalo de 0,12 a 12 ng/mg (r2 > 0,98). Amostras de cabelo de 8 usuários de Cannabis foram coletadas de pacientes provenientes de uma clínica dependentes pela equipe médica. O método mostrou-se eficiente em amostras de cabelos de usuários que faziam uso da droga pelo menos 10 vezes por semana. / A method was to develop to detect cannabinoids (cannabidiol, cannabinol and delta-9-tetrahydrocannabinol) in hair. A 10 mg of hair sample was descontaminated by dichloromethane followed by alkalin digestion, headspace solid-phase microextraction technique (HS-SPME) and analyzed by gas chromatography-mass spectrometry (CG/MS). The detection and quantitation limits were 0,07 and 0,12ng/mg respectively for all studied cannabinoids. The method proved to be simple, fast, precise and linear at the range of 0,12 to 12ng/mg (r2 > 0,98). Eight hair samples of Cannabis user were collected from patients at admittance from a dependence clinic by clinical staff. The method showed efficient in samples of users who use the drug at least 10 fold a week.
47

Técnicas de microextração aplicadas à análise estereosseletiva do ibuprofeno, da hidroxicloroquina e de seus metabólitos em urina / Microextraction techniques applied to the stereoselective analysis of ibuprofen, hydroxychloroquine and their metabolites in human urine.

Oliveira, Anderson Rodrigo Moraes de 21 June 2007 (has links)
A análise estereosseletiva tem um lugar de destaque em várias áreas e, dentre elas, a farmacêutica, pois diversos fármacos quirais são comercializados como misturas racêmicas. A análise estereosseletiva empregando a cromatografia líquida de alta eficiência e a eletroforese capilar é prática e bastante eficaz para aplicações que envolvem a determinação de enantiômeros ao nível de traços em matrizes complexas, como por exemplo, em estudos de disposição cinética. Entretanto, devido à complexidade das matrizes biológicas, há necessidade da preparação da amostra antes de sua análise. Entre as diversas técnicas existentes, as mais utilizadas são a extração líquido-líquido e a extração em fase sólida. Contudo, essas técnicas apresentam algumas desvantagens,sendo a principal delas o uso de grandes quantidades de solventes. Portanto, técnicas que requerem pouco ou nenhum consumo de solventes orgânicos são bastante desejáveis. Entre essas técnicas destacam-se a microextração em fase sólida (SPME) e a microextração em fase líquida (LPME). Essas técnicas relativamente recentes têm como vantagens a utilização de quantidades mínimas de solventes orgânicos, o alto poder de concentração, a remoção dos interferentes da matriz biológica e a simplicidade de automação. Nesse trabalho propusemos a utilização da SPME e LPME como técnicas de preparação de amostras de urina, visando o desenvolvimento de métodos estereosseletivos com detectabilidade e seletividade adequadas para aplicação em estudos posteriores de disposição cinética. A SPME foi empregada para análise estereosseletiva do ibuprofeno e de seus principais metabólitos, carboxiibuprofeno e 2-hidroxiibuprofeno e da hidroxicloroquina e seus principais metabólitos, enquanto que a LPME foi usada para a análise estereosseletiva da hidroxicloroquina e seus metabólitos. Inicialmente, foi realizada a otimização da separação dos fármacos e metabólitos em diversas colunas quirais,a otimização da separação da hidroxicloroquina e seus metabólitos por eletroforese capilar e,em seguida, a otimização dos procedimentos de extração e a validação dos métodos desenvolvidos. Utilizando a coluna Chiralpak AD-RH® e fase móvel composta por solução de ácido fosfórico 1 mol L-1 pH 3 : metanol (75 : 25, v/v), foi validado um método para análise enantiosseletiva do ibuprofeno em urina. A SPME foi empregada para extração do ibuprofeno das amostras de urina utilizando a fibra PDMS-DVB 60 6;m. O método mostrou ser linear na faixa de concentração de 0,25 a 25 μg mL–1 para cada enantiômero. Para a análise do 2-hidroxiibuprofeno e carboxiibuprofeno, foi utilizada a coluna Chiralpak AS® e fase móvel composta por hexano: isopropanol (94 : 6, v/v) + 0,05% de ácido trifluoracético. A extração desses metabólitos foi feita empregando a fibra de CW-TPR 50 µm. O método mostrou ser linear na faixa de concentração de 5 a 50 µg mL -1. Já para a análise da hidroxicloroquina e seus principais metabólitos, DHCQ e DCQ, foi utilizada a coluna Chiralcel OD-H® e fase móvel composta por hexano : etanol : metanol (96 : 2 : 2, v/v/v) + 0,2% de dietilamina. A extração desses metabólitos foi feita empregando a fibra de PDMSDVB 60 μm. O método mostrou ser linear na faixa de concentração de 50 a 1000 ng mL -1para HCQ e 42 - 416 ng mL-1 para os metabólitos. A microextração em fase líquida foi avaliada na análise da hidroxicloroquina e seus metabólitos, BDCQ, DHCQ e DCQ e separação por eletroforese capilar. Para tanto foi utilizado um capilar de sílica fundida nãorecoberto com um comprimento efetivo de 42 cm, e 30 mmol L-1 de HP-b-CD + 1% de CD-b- sulfatada dissolvida em tampão tris(hidroxiaminometano) 100 mmol L-1 pH 9 como tampão de análise. O método mostrou ser linear na faixa de concentração de 10 - 1000 ng mL-1 para HCQ e 21-333 ng mL-1 para os metabólitos. Obteve-se precisão com coeficientes de variação inferiores a 15% e exatidão com erros relativos menores que 15% para todos os métodos desenvolvidos. Após validação, os métodos foram empregados na determinação da quantidade excretada acumulada do do ibuprofeno, da hidroxicloroquina e de seus metabólitos após administração de de rac-ibuprofeno e rac-hidroxicloroquina a voluntários sadios. Em suma, as duas técnicas foram eficientes na extração dos fármacos e metabólitos estudados. A SPME mostrou ser uma técnica de mais fácil manuseio, porém com baixos valores de recuperação. Por outro lado, a LPME apresentou valores de recuperação maiores, porém o manuseio do sistema de extração foi mais difícil, necessitando de um tempo maior para o domínio da técnica. / The stereoselective analysis has been standing out in several areas, and it is mainly present in the pharmaceutical industry, since many drugs are marketed as racemic mixtures. The stereoselective analysis employing high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) is very useful for the determination of enantiomers at very low concentrations, as the ones found in biological matrices, for instance, in pharmacokinetic studies. The first step in the analysis of drugs in biological fluids is the extraction procedure. The most common extraction procedures employed are liquid-liquid extraction and solidphase extraction. These techniques show several drawbacks, such as the high amount of organic solvent consumed. So, based on this fact, techniques that consume small amounts of organic solvents are desirable. Among these techniques, solid-phase microextraction (SPME) and liquid-phase microextraction (LPME) have been stood out. The main advantages of these techniques are the small amount of organic solvent consumed and its high capacity in drug concentration. In this work, our purpose was to employ the SPME and the LPME as sample preparation techniques to develop stereoselective methods to be further applied in pharmacokinetic studies. SPME was employed for the stereoselective analysis of ibuprofen, hydroxychloroquine and their major metabolites.On the other hand,LPME was employed only for the enantioselective analysis of hydroxychloroquine and its metabolites. The first step was the separation optimization of the drugs and their metabolites by HPLC using several chiral columns, and the separation optimization of hydroxychloroquine and its metabolites by CE. Next, the extraction optimizations and method validations were performed. The enantioselective analysis of ibuprofen in human urine was carried out in the Chiralpak AD-RH® column, using methanol-pH 3.0 phosphoric acid solution (75 : 25 v/v) as mobile phase. The method was linear over the 0.5 - 25 µg mL-1 concentration range for both enantiomers. The fiber used in this method was PDMS-DVB 60 µm.The analysis of 2-hydroxyibuprofen and carboxyibuprofen was performed on a Chiralpak AS® column using hexane:isopropanol (95 : 5 v/v) plus 0.05% trifluoroacetic acid as the mobile phase. The method was linear over the 5 - 50 µg mL-1 concentration range. To perform the extractions, a CW-TPR 50 µm coated fiber was employed. The analysis of hydroxychloroquine and its major metabolites (DCQ and DHCQ) was done on a Chiralcel OD-H® column using hexane-methanol-ethanol (96 : 2 : 2, v/v/v) plus 0.2% diethylamine as mobile phase. The extraction was performed using a PDMS-DVB 60 µm coated fiber. The method was linear over the range of 50 - 1000 ng mL-1 for HCQ enantiomers and over the range of 42 - 416 ng mL-1 for DCQ and DHCQ enantiomers. LPME and CE were applied for the chiral determination of hydroxychloroquine and its metabolites (DCQ, DHCQ, BDCQ) in human urine. The electrophoretic separations were carried out in 100 mmol L-1tris(hydroxymethyl)aminomethane buffer (pH adjusted to 9.0 with phosphoric acid) containing 1% (w/v) S-b-CD and 30 mg mL-1 HP-?-CD, with a constant voltage of +18 kV. The method was linear over the concentration range of 10-1000 ng mL -1 for each HCQ stereoisomer and 21-333 ng mL -1 for each metabolite stereoisomer. Within-day and between-day assay precision and accuracy for all described methods were lower than 15%. The developed methods were applied for the determination of the cumulative urinary excretion of ibuprofen metabolites and hydroxychloroquine and its metabolites after oral administration of racibuprofen and rac-hydroxychloroquine to health volunteers. Comparing the techniques, both SPME and LPME were efficient to extract the drugs and their metabolites from human urine. iv SPME showed to be an easier technique to handle, however, the drug amount recovered by this technique was too small. On the contrary, LPME was a more difficulty technique to be handled, but better recovery values were obtained with this technique.
48

\"Otimização da extração, separação cromatográfica, identificação e quantificação de fármacos em fluidos biológicos\" / \"Optimization of the extraction, chromatographic separation, identification, and quantification of drugs in biological fluids\"

Fernandes, Christian 20 December 2006 (has links)
Este trabalho apresenta o desenvolvimento de diferentes métodos para a determinação de fluoxetina, norfluoxetina e bisfosfonatos, utilizando técnicas modernas de preparo de amostras. Dentre eles, um método simples e sensível, empregando microextração em fase sólida (SPME) e cromatografia líquida foi desenvolvido para a análise de fluoxetina e norfluoxetina em plasma. As condições de SPME foram otimizadas empregando planejamento fatorial. A extração foi realizada utilizando fibras com PDMS-DVB, e a etapa de dessorção foi realizada em uma nova interface homemade com sistema de aquecimento. Extração com sorção em barra de agitação (SBSE) com derivatização in-situ, combinada com dessorção com solventes ou dessorção térmica, acoplada à cromatografia gasosa e espectrometria de massas (GC-MS), foi também empregada para a determinação de fluoxetina em plasma. Avaliou-se a derivatização dos analitos in situ com cloroformato de etila, bem como os parâmetros tempo de extração, solvente e tempo de dessorção. A combinação de SBSE e LC-MS foi também avaliada. As amostras de plasma foram submetidas à precipitação de proteínas com ácido tricloroacético, extraídas com SBSE, e analizadas por LC-MS. Os métodos SPME-LC, SBSE-GC e SBSE-LC desenvolvidos foram completamente validados, demonstrando serem adequados para analisar fluoxetina em amostras de plasma. Métodos rápidos para a determinação de etidronato, clodronato, pamidronato e alendronato, baseados em cromatografia de troca iônica com detecção indireta no ultravioleta, foram também desenvolvidos. Os métodos são simples e demonstraram precisão, exatidão e especificidade. Além disso, os métodos validados empregam colunas de sílica, mais baratas e de mais disponibilidade do que as colunas poliméricas, frequentemente utilizadas em métodos descritos na literatura para o mesmo propósito. / This study describes different methods to analyze fluoxetine, norfluoxetine and bisphosphonates, employing modern sample preparation techniques. A simple and sensitive procedure using solid-phase microextraction (SPME) coupled with liquid chromatography was developed for the analysis of fluoxetine and norfluoxetine in plasma samples. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry (GC-MS), was employed for the analysis of fluoxetine. In situ derivatization using ethylchloroformate was evaluated as well as parameters such as solvent polarity, time for analytes desorption, and extraction time. SBSE combined with liquid chromatography and mass spectrometry was also used to analyze fluoxetine in plasma. Plasma samples were first submitted to protein precipitation with trichloroacetic acid, subjected to SBSE, and thereafter analyzed by LC-MS. SPME-LC, SBSE-GC, and SBSE-LC methods were completely validated showing to be adequate to assess fluoxetine in plasma samples. Rapid methods for etidronate, clodronate, pamidronate and alendronate assay were also developed. The methods were based on ion chromatography with indirect ultraviolet detection, which avoids the need for chemical derivatization procedures. The methods were simple, rapid, and demonstrated precision, accuracy, and specificity. Furthermore, they employed silica-based columns, cheaper and more readily available than polymeric columns, frequently used in previous reported methods.
49

Determinação de canabinóides em cabelo por microextração em fase sólida por Headspace e análise por espectrometria de massa associada à cromatografia em fase gasosa / Determination of cannabinoids in hair by Headspace solid-phase microextraction and gas chromatography-mass spectrometry

Carolina Dizioli Rodrigues de Oliveira 21 July 2005 (has links)
Foi desenvolvido um método para determinar canabinóides (canabidiol, canabinol e delta-9-tetraidrocanabinol) no cabelo. Uma amostra de 10mg foi descontaminada com diclorometano, seguida de digestão alcalina, microextração em fase sólida por headspace (HS-SPME) e analisada por espectrometria de massa associada à cromatografia em fase gasosa (GC/MS). Os limites de detecção e de quantificação foram de 0,07 e 0,12 ng/mg, respectivamente, para todos canabinóides estudados. O método demonstrou ser simples, rápido, preciso e linear no intervalo de 0,12 a 12 ng/mg (r2 > 0,98). Amostras de cabelo de 8 usuários de Cannabis foram coletadas de pacientes provenientes de uma clínica dependentes pela equipe médica. O método mostrou-se eficiente em amostras de cabelos de usuários que faziam uso da droga pelo menos 10 vezes por semana. / A method was to develop to detect cannabinoids (cannabidiol, cannabinol and delta-9-tetrahydrocannabinol) in hair. A 10 mg of hair sample was descontaminated by dichloromethane followed by alkalin digestion, headspace solid-phase microextraction technique (HS-SPME) and analyzed by gas chromatography-mass spectrometry (CG/MS). The detection and quantitation limits were 0,07 and 0,12ng/mg respectively for all studied cannabinoids. The method proved to be simple, fast, precise and linear at the range of 0,12 to 12ng/mg (r2 > 0,98). Eight hair samples of Cannabis user were collected from patients at admittance from a dependence clinic by clinical staff. The method showed efficient in samples of users who use the drug at least 10 fold a week.
50

Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsões

Krahn, Carolina Lopes January 2010 (has links)
O objetivo do presente trabalho foi desenvolver e validar um método analítico empregando microextração em fase sólida (SPME) para detecção e quantificação de isoflurano (ISO) na forma volátil e incluso em nanoemulsões intravenosas e, ainda, avaliar o efeito biológico destas. A detecção do ISO foi realizada através de cromatografia em fase gasosa com detector de ionização de chama (CG/DIC). As condições ideais para realização da pré-concentração e extração de ISO através da técnica de SPME foram temperatura ambiente, agitação constante, 30 min de extração e 2 min de dessorção no injetor do CG. O método desenvolvido foi validado avaliando os parâmetros de especificidade, linearidade, limites de detecção e quantificação, precisão, exatidão e robustez. As nanoemulsões contendo ISO foram desenvolvidas através da homogeneização à alta pressão, e apresentaram diâmetro médio, índice de polidispersão, potencial zeta e pH de 150 ± 0,78 nm, 0,08 ± 0,01, - 18 ± 2,4 mV e 6,03 ± 0,04, respectivamente. O pH foi ajustado para 7,4 (valor fisiológico). O teor de ISO nas formulações foi de 98,4 %. Não houve modificação das características físico-químicas das nanoemulsões após 30 dias de armazenamento a 8 ºC. Análises de espalhamento de luz múltiplo não demonstraram tendência a fenômenos de instabilidade física para as formulações. Os estudos do efeito anestésico das nanoemulsões intravenosas contendo ISO em cães evidenciaram uma redução significativa (p < 0,05) na dose comparada com a administração de ISO volátil. Não houve alterações no débito cardíaco, saturação de oxigênio na hemoglobina e nos biomarcadores das funções renal, hepática e muscular. Uma queda na pressão arterial dos cães foi observada em todos os tratamentos devido ao efeito hipotensor do ISO. Após administração das nanoemulsões contendo ISO e branca, observou-se taquipnéia, edema, eritema, e baixas concentrações de dióxido de carbono expiradas. Assim, a nanoemulsificação do ISO foi realizada com sucesso e a aplicação na anestesia geral intravenosa foi demonstrada. / The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion’s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p < 0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog’s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.

Page generated in 0.0793 seconds