• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 561
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 574
  • 574
  • 574
  • 287
  • 281
  • 265
  • 66
  • 64
  • 63
  • 63
  • 55
  • 55
  • 51
  • 51
  • 49
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
551

Análise estrutural e comparativa do genoma de Leifsonia xyli subsp. xyli. / Structural and comparative analysis of the genome of leifsonia xyli subsp. xyli.

Paulo Roberto Gagliardi 26 September 2003 (has links)
Leifsonia xyli subsp. xyli (Davis et al.; 1984; Evtushenko et al.; 2000) é agente causal de uma das mais importantes doenças da cana-de-açúcar: o raquitismo-da-soqueira (Gillaspie Jr. & Davis, 1992; Davis et al.; 1994). O presente trabalho teve como objetivo principal usar métodos de análise cromossômica para corroborar o mapa genômico da estirpe CTC B07 de L. xyli subsp. xyli obtido através do seqüenciamento por “shotgun”, realizado pelo grupo de seqüenciamento de Genomas Agronômicos e do Meio-ambiente (AEG) da rede ONSA-FAPESP. A identidade do isolado foi confirmada com a amplificação e seqüenciamento da região 23S do rRNA bem como por meio de testes sorológicos de microaglutinação com antissoro específico. Além destes, foram realizados testes de microscopia eletrônica de varredura da bactéria cultivada em meio líquido para confirmar a pureza do isolado. O tamanho do genoma de L. xyli subsp. xyli foi estimado com base na análise de fragmentos de restrição gerados por digestões com as enzimas de restrição XbaI e SpeI e eletroforese de campo pulsado (PFGE). As estimativas de 2.540 kb e 2.530 kb com XbaI e SpeI respectivamente ficaram próximas ao valor obtido pelo seqüenciamento genômico (2.596.959 pb). Em adição, o número de seqüências repetidas e de genes ribossomais identificados pelo projeto genoma foram confirmados por meio de hibridizações com sondas apropriadas. Comparações genômicas de L. xyli subsp. xyli, L. xyli subsp. cynodontis e duas espécies de Clavibacter também foram objetivos deste trabalho. As comparações foram baseadas em análise de RFLPs após a hibridização do DNA genômico utilizando como sondas elementos genéticos móveis presentes no genoma de L. xyli subsp. xyli. As estimativas dos números estimado de cópias destes elementos no genoma de L. xyli subsp. xyli obtidas por hibridizações concordam com aquelas obtidas pelo seqüenciamento, considerando fragmentos RFLPs menores que 9 kb. Informações referentes à fragmentos maiores não foram obtidas uma vez que estes não foram adequadamente resolvidos na corrida eletroforética. Finalmente, comparações através de análise de RFLP e rep-PCR mostraram diferenças entre L. xyli subsp. xyli e L. xyli subsp. cynodontis bem como entre estas e espécies de Clavibacter. Não foram verificadas diferenças entre a estirpe CTC B07 de L. xyli subsp. xyli e a estirpe australiana. / Leifsonia xyli subsp. xyli (Davis et al.; 1984; Evtushenko et al.; 2000) is the causal agent of one of the most economically important disease of sugarcane worldwide, i.e, ratoon stunting disease (Gillaspie Jr. & Davis, 1992; Davis et al.; 1994). The main objective of this study was to confirm the assembly of the genome of L. xyli subsp. xyli obtained after shotgun sequencing by the Agronomic and Enviromental Genomes group of the ONSA/FAPESP network. The identity of the strain was confirmed by amplification and sequencing of the 23S rRNA region as well as by microaglutination serological tests with specific antiserum. Besides this, scanning electron microscopic analysis was used to assess the purity of the strain culture. The size of the genome of L. xyli subsp. xyli was estimated based on restriction analysis after digestion of genomic DNA with SpeI and XbaI followed by pulsed-field gel electrophoresis. The estimates of 2,530 kb and 2,540 kb, respectively for SpeI and XbaI, are in agreement with the one obtained by whole genome sequencing (2,596 kb). In addition, the number of repeated sequences and ribossomal genes predicted by thesequencing project was confirmed by hybridization experiments with the appropriate probes. Genomic comparisons of L. xyli subsp. xyli, L. xyli subsp. cynodontis and two Clavibacter species comprised a second objective of this study. Comparisons were based on RFLP analysis after hybridization of digested genomic DNA using mobile genetic elements present in the genome of L. xyli subsp. xyli as probes. The estimates of number of copies of these elements in the genome of L. xyli subsp. xyli obtained by this approach agreed with the ones obtained by sequencing if RFLP fragments smaller than 9 kb are considered. Data from larger fragments were not obtained since they were not adequately resolved by electrophoresis. Finally, RFLP and rep-PCR comparisons unveiled differences between L. xyli subsp. xyli and L. xyli subsp. cynodontis as well as between these and Clavibacter. No differences were found between strain CTC B07 of L. xyli subsp. xyli and an Australian strain.
552

Cimentos resinosos endodônticos: selamento apical, aspectos micromorfológicos, características físicas e resistência de união à dentina / Resin-based root canal sealers: apical sealing, micromorphological aspects, physical characteristics and bond strength to dentin

Soráia de Fátima Carvalho Souza 12 December 2007 (has links)
Avaliou-se o selamento apical, os aspectos micromorfológicos da interface adesiva, as características físicas e a resistência de união à dentina de cimentos resinosos endodônticos. Setenta e dois pré-molares humanos unirradiculares foram preparados endodonticamente. Trinta e três dentes foram divididos aleatoriamente em 3 grupos, impermeabilizados externamente e obturados pela técnica da condensação lateral acorde as seguintes condições: AH Plus (AH Plus/Gutapercha); AH Primer (Epiphany primer/AH Plus/Gutapercha) e Epiphany (sistema Epiphany). Foram mantidos a 37oC e 100% de umidade por 72 h e, em seguida, imersos em solução aquosa de nitrato de prata a 50% por 24 h. Após secção longitudinal dos dentes, foram realizadas réplicas em resina epóxica. Réplicas e espécimes foram preparados para MEV. Nas réplicas, observou-se a freqüência de fendas apicais na interface dentina/cimento. Nos espécimes, detectou-se e confirmou-se com EDS (Energy Dispersive Spectroscopy) a microinfiltração apical. A interface dentina/cimento foi observada em seis espécimes de cada grupo, selecionados aleatoriamente. A microinfiltração foi similar entre os grupos (p>0,05), sendo influenciada pela freqüência de fendas (p<0,05). Foram observadas tanto regiões com fendas quanto com camada híbrida e longos tags para o grupo Epiphany. Para os grupos AH Primer e AH Plus foi verificada boa adaptação marginal com longos tags vazios e pequenos plugs, respectivamente, embora tenha ocorrido a formação de fendas em ambos. Os outros dentes foram utilizados para as avaliações adicionais: seis, para complementar o estudo micromorfológico da interface adesiva; três, para o ensaio de microdureza Knoop; e, trinta, para o teste de resistência de união. O cimento Epiphany mostrou maior escoamento (p<0,001) e tensão de polimerização (p<0,05), e a menor resistência de união (p<0,001). Os valores de microdureza Knoop decresceram acentuadamente de cervical para apical (p<0,001). Concluiu-se que a total impermeabilização do sistema de canais radiculares não foi obtida com nenhum dos cimentos testados, e que o sistema Epiphany formou mais fendas no ápice. / Resin-based root canal sealers had their apical sealing, micromorphological aspects, physical characteristics and bond strength to dentin evaluated in this study. For this purpose, seventy-two single-rooted human premolars were endodontically treated. Thirty-three teeth were randomly divided into three groups, externally coated with nail varnish and obturated by lateral condensation technique according to such conditions: AH Plus (AH Plus/Gutta-percha); AH Primer (Epiphany primer/AH Plus/ Gutta-percha) and Epiphany (Epiphany system). They were kept in 100% humidity at 37oC for 72 h, and then the specimens were immersed in 50% aqueous silver nitrate tracer solution for 24 h. The teeth were longitudinally sectioned and their epoxy resin replicas were obtained. Both the specimens and their corresponding replicas were prepared for SEM. In the replicas, the frequency of apical gaps at the dentin/cement interface was observed. In the specimens, the apical microleakage was detected and confirmed by EDS (Energy Dispersive Spectroscopy). The dentin/cement interface was observed in six specimens of each group randomly selected. The microleakage was similar among the groups (p>0,05) being influenced by gaps frequency (p<0,05). The Epiphany group presented gap-containing regions, hybrid layer formation and long tags. For AH Primer and AH Plus groups, good marginal adaptation with long empty tags and small plugs, respectively, although gaps formation was found in both groups. The remaining teeth were used for other evaluations: six, to finish micromorphological study at the adhesive interface; three, for Knoop microhardness; and thirty, for bond strength test. The Epiphany resin sealer has showed the highest flow (p<0.001) and polymerization stress (p<0.05), and the lowest bond strength values (p<0.001). The Knoop microhardness values have decreased excessively from the cervical to the apical third (p<0.001). It was concluded that none of the sealers tested achieved a complete sealing of the root canals system, and the Epiphany system has developed more gaps to the apex.
553

Síntese e processamento de compósito cerâmico zircônia-grafeno / Synthesis and processing of zirconia-graphene ceramic composite

Diego Santos Manarão 27 February 2018 (has links)
O objetivo desse trabalho foi desenvolver um compósito cerâmico de zircônia-grafeno para aplicação odontológica. Este estudo avaliou o efeito do pó de partida, concentração de grafeno e da temperatura de sinterização sobre as propriedades mecânicas (dureza e tenacidade à fratura) do compósito desenvolvido. Para isto foram sintetizados os pós de Y-TZP a partir de soluções de óxido-cloreto de zircônio e cloreto de ítrio na proporção desejada de 3mol% através da rota de co-precipitação em solução de hidróxido de amônio seguido por uma série de lavagens em água, etanol e butanol com posterior destilação azeotrópica, secagem, moagem e calcinação. O grafeno foi obtido a partir da exfoliação química de grafite pelo método de Hummers [40] modificado por Marcano [39], o que resultou em um gel acastanhado que foi submetido a lavagem por centrifugação, secagem e desaglomeração em almofariz de ágata, resultando, por fim, no óxido de grafeno. Uma segunda etapa foi o processo de redução química com ácido ascórbico para obtenção de óxido de grafeno reduzido, um pó de coloração escura que foi adicionado à Y-TZP para a obtenção do compósito nas diversas concentrações (em mol%) que foram estudadas: (0,01%, 0,05%, 0,10%, 0,50%, 1,00% e 2,00%). Os pós foram caracterizados por termogravimetria, difração de raios X e espectroscopia (FT-IR). Os espécimes foram confeccionados em matriz metálica cilíndrica e sinterizados em forno tubular em atmosfera inerte. Outros espécimes foram confeccionados em matriz de grafite de alta densidade e sinterizados por Spark Plasma Sintering (SPS). Todas as amostras foram caracterizadas por meio de ensaios de densidade, dureza Vickers, tenacidade à fratura e microscopia eletrônica de varredura. Os maiores valores de densidade relativa foram observados para as amostras sinterizadas em SPS, sendo que se obteve valor de densidade relativa de 98,7 % para a concentração de 0,50% de grafeno e 98,4% para a Y-TZP pura. Por outro lado, o maior valor encontrado em sinterização em atmosfera a 1400°C sem a presença de H2 para Y-TZP pura foi da ordem de 96,76%. Os valores de dureza foram maiores nas amostras sinterizadas em SPS, no entanto a tenacidade à fratura mostrou não se alterar em função do conteúdo de grafeno. As fotomicrografias de MEV mostraram que houve uma variação de tamanho de grão de acordo com a presença do grafeno e do método de sinterização. De acordo com os resultados obtidos neste trabalho foi possível concluir que o processamento desenvolvido permitiu a criação de um compósito cerâmico zircônia-grafeno que pôde ser caracterizado por diversos métodos analíticos. A densidade teórica do compósito desenvolvido não foi alcançada por meio de nenhum dos métodos de sinterização utilizados (Tubular ou SPS) e nem variando-se a temperatura. Para espécimes sinterizados em atmosfera inerte, a maior temperatura de sinterização (1400°C) e a presença do gás H2 não melhorou a densificação. Além disso, esses espécimes tiveram aumento da dureza com o aumento da concentração de grafeno, entretanto, a sua tenacidade à fratura não foi afetada pelo teor de grafeno. Para espécimes sinterizados por meio de SPS, a temperatura de sinterização de 1350°C resultou em melhores valores de densificação. Além disso, para este tipo de sinterização, tanto a dureza como a tenacidade à fratura foram afetadas pelo teor de grafeno. / The objective of this work was to develop a zirconia-graphene ceramic composite for dental application. The study evaluated the effect of the starting powder effect, graphene concentration and sintering temperature on the mechanical properties of the composite. For this, the Y-TZP powders were synthesized from zirconium chloride and yttrium chloride solutions in the desired ratio of 3 mol% through the co-precipitation route in ammonium hydroxide solution followed by a series of washes in water, ethanol and butanol with subsequent azeotropic distillation, drying, grinding and calcination. Graphene was obtained from the chemical exfoliation of graphite by the method of Humans modified by Marcano, which resulted in a brownish gel that was subjected to washing by centrifugation, drying and deagglomeration in agate mortar, resulting finally in the graphene oxide. A second step was the chemical reduction with ascorbic acid to obtain reduced graphene oxide, a dark-colored powder that was added to the Y-TZP to obtain the composite in the various concentrations (in mol%) that were studied (0, 01%, 0.05%, 0.10%, 0.50%, 1.00% and 2.00%). The powders were characterized by thermogravimetry, X-ray diffraction and spectroscopy (FT-IR). The specimens were made in cylindrical metallic matrix and sintered in a tubular oven. Other samples were made in high density graphite matrix and sintered by Spark Plasma Sintering (SPS). All samples were characterized by means of density tests, Vickers hardness, fracture toughness and scanning electron microscopy. The highest values of relative density were observed for the sintered samples in SPS. A relative density of 98.7% was obtained for the 0.50% concentration of graphene and 98.4% for the pure Y-TZP. On the other hand, the highest value found in tubular sintering at 1400 ° C without the presence of H2 for pure Y-TZP was of the order of 96.76%. The hardness values were higher in the sintered samples in SPS, however the fracture toughness showed not to change as a function of the content of graphene. SEM images showed that there was a variation of grain size according to the presence of graphene and the sintering method. According to the results of this study it was concluded that the process developed allowed the creation of a graphene-zirconia ceramic composite which can be characterized by various analytical methods. The theoretical density of the composite developed was not achieved by any of the sintering methods used (tubular or SPS) nor by varying the temperature. For tubular sintered specimens, the higher sintering temperature (1400 ° C) and the presence of H2 gas did not improve densification. In addition, these specimens had increased hardness with increasing graphene concentration, however, their fracture toughness was not affected by graphene content. For sintered specimens by SPS, the sintering temperature of 1350 ° C resulted in better densification values. In addition, for this type of sintering, both hardness and fracture toughness were affected by the content of graphene
554

Estudo do laser Erbium Glass fracionado não ablativo no tratamento do fotoenvelhecimento cutâneo: avaliação clínica, histopatológica, microscopia eletrônica e imuno-histoquímica / Study of Erbium Glass Laser Fractional non-ablative treatment of photoaging: clinical evaluation, histophatology, electron microscopy and immunohistochemistry

Regina Celli Ribeiro Patriota 22 October 2013 (has links)
Introdução: Os lasers fracionados não ablativos são efetivamente utilizados no rejuvenescimento da pele. As novas tecnologias a laser permitem uma remodelação dérmica seletiva, sem ablação da epiderme. Objetivo: Avaliar a eficácia do laser Erbium Glass (Sellas Evo) fracionado não ablativo 1550nm no rejuvenescimento facial através do estudo da quantificação histomorfométrica de fibras colágenas e elásticas, a expressão da molécula de adesão intercelular 1 (ICAM-1) por imuno-histoquímica , a análise das fases do ciclo celular, o potencial elétrico da membrana mitocondrial, a expressão de interleucina-1 (IL-1), o marcador celular endotelial CD34, o receptor do fator transformador de crescimento beta (TGF-beta), atividade da caspase-3 por citometria de fluxo e as alterações ultraestruturais na pele por microscopia eletrônica de varredura, 4 meses após o tratamento com laser. Materiais e Métodos: Quinze indivíduos (média de 56,4 anos, fototipo II-IV), com fotoenvelhecimento cutâneo na face fizeram 3 tratamentos com laser Erbium Glass fracionado não ablativo 1550nm usando uma fluência de 70 mJ e uma densidade de 100 cm2. Foram avaliados biópsias na região pré-auricular em 15 pacientes no início e 4 semanas após o tratamento final. Os níveis de expressão dos receptores e a atividade do potencial elétrico mitocondrial foram analisados na suspensão de células da derme obtida a partir da digestão por colagenase. A avaliação clínica e fotográfica foi analisada quatro semanas após o final do tratamento. Resultados: Após 4 meses do início do tratamento foi observada melhora clínica moderada, com uma média de satisfação de 8,8, as fibras de colágeno aumentaram em 6,68%, as fibras elásticas mostraram uma diminuição de 12,85%, o ICAM-1 aumentou 4,47% significativamente na área dos vasos. Houve aumento significativo dos níveis de expressão do receptor de IL-1 e TGF-beta após o tratamento com laser Erbium Glass. As respostas proliferativas e a ausência de apoptose dependente da caspase-3 foram observadas nas suspensões de células após o tratamento. Conclusão: Rejuvenescimento facial com laser Erbium Glass fracionado não ablativo 1550nm demonstrou melhora visível no fotoenvelhecimento, assim como, aumento significativo da expressão de IL-1 e receptores de TGF-beta, que estão envolvidos na remodelação e indução da proliferação de componentes da matriz extracelular da pele. O grau de satisfação foi alto especialmente em relação à textura, rugas e discromias / Background: Non-ablative fractional lasers have been effectively used in skin rejuvenation. The new laser technologies allow selective dermal remodeling without ablation of the epidermal surface. Objectives: to evaluate the efficacy of the 1550nm Erbium Glass Laser (Sellas Evo) for facial rejuvenation through study of the histomorphometric quantification of colagen and elastic fibers; the expression of intercellular adhesion molecule 1 (ICAM-1) by immnohistochemistry; and analysis of the cell cycle phases, the electrical potential of the mitochondrial membrane and the expression of interleukin 1 (IL-1), the endothelial cell marker CD34 and transforming growth factor beta (TGF-beta) receptors, caspase-3 activity by flow cytometry and the ultrastructural changes in the skin by scanning electron microscopy 4 months after the laser treatment. Materials and methods: fifteen subjects (mean age 56,4 skin typoes II-IV) with photodamage on the face and wrinkles had 3 treatments with the 1550 nm Erbium Glass Laser using a fluence of 70 mJ and a density of 100 cm2. Pre-auricular biopsies from 15 subjects were evaluated at baseline and 4 weeks after the final treatment. Receptor expression levels and the presence of potentially functional mitochondria were analyzed in a cell suspension obtained from collagenase digestion of the skin. Data from the photo assessments and the subjects\' self-assessed improvements were analyzed 4 weeks after the final treatment.Results: Four months after the last treatmenbt application, clinical improvement was observed, with an average satgisfation score of 8.8, corresponding to moderate improvement. After 4 months of treatment, collagen fibers had increased up to 6.68%, while the average proportion of collagen fibers in the dermis, the elastic fibers, showed a 12.85% decrease of ICAM-1 and a mean increase in vessel area of 4.47%.Significantly enhanced IL-1 and TGF-beta receptor expression levels were identified after Erbium Glass Laser treatment. Proliferative responses and non-apoptosis-dependent caspase-3 activity were both observed in the cell suspensions after dermal treatment. Conclusion: Non-ablative rejuvenation with the 1550 mn Erbium Glass Laser was of the IL-1 and TGF-beta receptors, that are involved in remodeling and induced proliferation components in the extracellular matrix of skin fibers. The subjects were highly satisfied, especially regarding texture, rhytids and dyschromia
555

Propriedades de corrosão e caracterização química – metalográfica de próteses em aços inoxidáveis ISO 5832-9 e F138, removidas de pacientes

Silva, Elison da Fonseca e 26 November 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-03T13:18:17Z No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:33:58Z (GMT) No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Made available in DSpace on 2017-05-13T13:33:58Z (GMT). No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) Previous issue date: 2010-11-26 / Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações como biomateriais, utilizados na fabricação de implantes ortopédicos, removidos de pacientes afetados por quadro inflamatório, e comparou as superfícies das amostras, através da Microscopia Eletrônica de Varredura (MEV) após ataque eletroquímico. Os resultados da análise química, por Espectrometria de Emissão Ótica e Microanálise por Dispersão de Energia (EDS), mostraram que todos os grupos apresentaram conformidade com as normas ASTM F138-92 e ABNT NBR ISO 5832-9:2008. O tamanho de grão foi determinado por Microscopia Ótica e Microscopia Eletrônica de Varredura (MEV). As superfícies das amostras foram analisadas por Microscopia Eletrônica de Varredura (MEV), depois de serem submetidos a ensaio de polarização cíclica potenciodinâmica em potencial de 50 mV após a região passiva em meio de solução de Ringer Lactato e solução de NaCl 0,9 mol.L-1na temperatura de 36,5 oC. Essas análises por MEV foram conduzidas nas amostras para identificar o tipo de corrosão apresentada. Concluiu-se que todos os implantes apresentavam tamanho de grão superior ao recomendado pela norma. Constatou-se também a presença de ferrita delta em oito dos doze implantes removidos, que de acordo com a norma ASTM 138-92, não deveria ser percebida microscopicamente com um aumento de 100 vezes. Verificou-se ainda que em meio de NaCl, o aço ISO 5832-9 ao contrário do aço F138, não apresentou nenhuma forma de corrosão localizada. Em solução de Ringer lactato, após ataque por 15 min. no potencial de 1000 mV/ECS foi notada a presença de pites no aço ISO 5832-9. O ensaio de polarização cíclica revelou que um dos aços, identificado como ISO 5832 9 apresentou resistência à corrosão localizada muito superior ao outro identificado como F 138, além de não liberar íons metálicos nas soluções eletrolíticas. Essa propriedade é principalmente atribuída ao aumento da estabilidade do filme passivo, que por sua vez, é favorecida pela presença do nitrogênio em solução sólida intersticial na austenita do aço ISO 5832-9. Os ensaios de polarização revelaram-se úteis para indicar a baixa resistência à corrosão por pites exibida “in-vitro” pelas próteses. As amostras do aço F 138 após serem submetidas ao ensaio eletroquímico em solução de Ringer lactato apresentaram perdas de 63% de níquel e 26% de ferro em relação à composição inicial. Tais elementos foram deslocados eletroquimicamente na forma iônica para a solução de Ringer lactato, onde formaram precipitados sendo, portanto, um forte indicador de que as reações sofridas pelos portadores das próteses foram motivadas por esses íons metálicos, que são posteriormente incorporados no organismo. Pretende-se com os resultados dessa pesquisa propor aos órgãos governamentais reguladores de normas técnicas e de vigilância sanitária, bem como a médicos e hospitais que exijam dos fabricantes de próteses de aços inoxidáveis laudos técnicos que atestem a qualidade dos implantes, onde cada lote de fabricação das peças seja acompanhado por certificados garantindo a composição química e as características metalográficas especificadas pelas norma existentes no Brasil. / This work has studied the chemical and metallographic composition (microstructure, grain size, inclusion rate) of austenitic stainless steels which were developed to be applied as biomaterials, and used in the production of orthopedical implants, removed from patients which had been affected by inflammation; it has also been compared the sample surfaces, by means of scanning electronic microscopy (SEM) after electrochemical attack. The results of chemical analysis, performed by optical emission spectroscopy and Energy Dispersive Spectroscopy (EDS) have shown that all samples are in agreement with the ASTM F138-92 e ABNT NBR ISO 5832-9:2008 regulations, whereas the grain size has been determined by optical microscopy and SEM. The surfaces of the samples were analyzed by SEM and EDS techniques; samples were submitted to potentiodynamic cyclic polarization tests in 50 mV potential after the passivation region in Ringer lactate and NaCl 0,9 mol.L-1 solutions at 36,5C; such SEM measurements were done to identify the type of corrosion over the samples. It has been concluded that all implants showed average grain sizes above the recommended by the regulations; also the presence of delta ferrite in eight of the twelve investigated implants has been seen, which according to the ASTM 138-92 regulation this would not been possible even with a 100-fold increase at the optical microscope. It has also been verified that in NaCl medium the ISO 5832-9 steel did not present any kind of localized corrosion, instead of F 138 steel; in Ringer lactate solution, after 15 minutes attack at 1000mV/SCE, has been noted the presence of pits for ISO 5832-9 steel. The cyclic polarization measurements have revealed that one of the investigated steels, named ISO 5832-9, presented a very high resistance to localized corrosion when compared to the F 138 samples, besides they did not release metallic ions to the electrolytic solutions. This characteristic can be mainly attributed to the increasing of the passivation film stability, which is also favored by the presence of nitrogen atoms in the solid solution composing the structure of ISO 5832-9 steel. The pit corrosion tests have shown very useful to indicate the low resistance to pit corrosion, present “in-vitro” in all the studied samples. The EDS mapping analysis of F 138 samples, submitted to electrochemical attack in Ringer lactate medium, have shown a loss of 63% of nickel and 26% of iron, when compared to the initial composition; such metals were electrochemically solubilized to the Ringer lactate solution, where they can probably precipitate from the solution, being a strong indication that the reactions taking place in the patients have been motivated by these metal ions, which can be incorporated by the human body. The obtained results of this work are the basis of a tentative proposition to the governmental organisms which are the responsible for the regulation of the technical specifications for the prosthesis producers, requiring from them technical reports assuring the quality for the implant pieces, i.e., for each manufacturing lot a description or a special certificate containing the chemical composition and the metallographic characteristics specified by the Brazilian laws.
556

Traços de íons em apatita = ataque químico, tratamento térmico e modelagem / Ion tracks in apatite : chemical etching, thermal annealing and modelling

Vellame, Igor Alencar, 1984- 09 May 2012 (has links)
Orientadores: Sandro Guedes de Oliveira, Julio Cesar Hadler Neto / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-21T04:43:57Z (GMT). No. of bitstreams: 1 Vellame_IgorAlencar_D.pdf: 6307121 bytes, checksum: 509c7cc3c5c11f238463340fa191af50 (MD5) Previous issue date: 2012 / Resumo: O presente trabalho pode ser inserido na grande área de estudo da interação da radiação com sólidos. Ele tem como principal objetivo entender a cinética de reconstituição dos danos causados por irradiação com íons ( traço latente) na apatita e e realizado através do estudo de annealing em traços atacados. O que se denomina traço latente e a trilha de danos causada pela desaceleração do íon, enquanto este atravessa a matéria. Estes traços latentes são meta-estaveis em relação ao tratamento térmico e apresentam uma taxa de reação a dissolução muito mais elevada que o mineral não danificado. Assim, para compreender as alterações causadas pelos tratamentos térmicos e necessária entender como o processo de ataque químico ocorre. Um cristal natural de apatita foi cortado em algumas orientações cristalográficas (principalmente basal e prismática) e estas amostras foram montadas em resina para obtenção de uma superfície plana com técnicas de polimento. Grande parte destas amostras foi irradiada com nêutrons (para induzir a fissão do isótopo 235 U com fluências de nêutrons térmicos próximas a 3xl015 cm-2 ) ou com íons pesados (152Sm e 238 U com fluências pr6ximas a lx106 cm-2 e 5x 1011 cm-2). Utilizando a espectroscopia no infra-vermelho, foi possível estimar o valor do diâmetro do traço latente. Os valores encontrados (~8-9 nm) são coerentes com diversas medidas utilizando outras técnicas presentes na literatura. As taxas de dissolução da superfície do material pelo acido nítrico em diferentes condições (concentração e temperatura) foram medidas pelo método da máscara com êxito. Observou-se uma inversão na razão entre as taxas para as diferentes orientações conforme a concentração do reagente aumentada. A distribuição de comprimentos projetados também foi estudada para estimar a eficiência de observação e revelação do ataque químico (razão entre quantos traços são efetivamente contados e quantos traços são gerados). A metodologia presente na literatura para o calculo da distribuição de comprimentos projetados foi revista e novas estimativas foram feitas utilizando métodos numéricos com intuito de estimar os comprimentos e desvios dos fragmentos de fissão leve e pesado na apatita. Foi observada uma deficiência intrínseca na medida do comprimento projetado, mas esta sozinha não e capaz de explicar o deficit de alcance observado para as irradiações com íons. Duas metodologias para o ca1culo do conteúdo de urânio nas amostras são apresentadas e os resultados da comparação com valores obtidos par outras técnicas independentes são satisfatórios. Isto fortalece o método dos traços de fissão como uma técnica absoluta para a dosimetria de nêutrons. Par fim, para o estudo do tratamento térmico, dais conjuntos de dados pana traços de íons foram preparados: um a partir da diminuição do comprimento projetado; e outro com o estudo da variação na abertura superficial de traços de íons incidentes perpendicularmente. Foi possível correlacionar as reduções da abertura superficial e do comprimento através de uma lei de potencia. Aparentemente, a abertura superficial parece ser um indicador da quantidade de defeitos e isto possibilita vincular melhor a cinética do tratamento térmico. Algumas extrapolações geológicas também foram realizadas e o razoável acordo com os dados geológicos demonstra que o processo e universal e que traços de íons podem ser usados como ferramenta para o estudo do tratamento térmico em traços atacados / Abstract: This work can be inserted in the great study area of radiation interactions with solids. It has as the main goal the understanding of the reconstitution of damage caused by ion irradiation (latent track) in apatite and it is investigated through the annealing of chemically etched tracks. A latent track is the damage trail caused by the ion deceleration in matter. These tracks are thermally meta-stable and they present an enhanced dissolution rate when compared to the non-damaged bulk mineral. Thus, in order to understand t he alterations caused by a thermal treatment, it is necessary to understand how does the chemical etching occur. A natural apatite crystal was cut in some crystallographic orientations (mainly basal and prismatic) and these samples were mounted in epoxy resin in order to obtain a fiat surface with polishing techniques. Great part of these samples were irradiated with thermal neutrons (inducing the 235 U fission with fiuence close to 3x 1015 cm-2 ) or heavy ions e 52Sm and 238U with nominal fluences of lx106 cm-2 and 5x1011 cm-2 ). Applying infra-red spectroscopy, it was possible to estimate the values of ion latent track diameters. The founded values (~8-9 nm) are coherent with several measurements employing other techniques presented in the literature. The mineral surface dissolution rates by nitric acid were successfully measured in different conditions ( etchant concentration and temperature) with the mask method. As the etchant concentration increases, an inversion in the dissolution rates ratio between different orientations was observed. The projected length distribution was also studied to estimate the revelation/observation efficiency (ratio between how many tracks were effectively counted and how many are expected). The methodology presented in the literature for the calculation of the expected projected length distribution was revised and new estimates were made with numerical methods. These numerical methods were employed to estimate the length and standard deviation of light and heavy fission fragments in apatite. An intrinsic deficit in the projected length measurement was observed. However, it alone could not explain the huge range deficit observed for external source irradiation in apatite. Two methodologies for the calculation of uranium content in t he samples were proposed. The comparison of the results with other values found from independent techniques was satisfactory. This strengthen the fission track method as an absolute technique for neutron dosimeter. Finally, two data sets for ion track thermal annealing study were prepared:! one from the shortening of projected length; and the other from the variation of perpendicular ion track etch-pit aperture. It was possible to correlate the aperture and length reduction with a power law. Apparently, the etch-pit aperture seems to be an indicator of the amount of defects which remains in the latent track after the thermal treatment. This enables one to better constrain the thermal annealing kinetic. Some geological extrapolation were also predicted. The reasonable agreement with geological data demonstrates that the process is universal and that ion tracks can be used as proxies for the thermal annealing behavior study / Doutorado / Física / Doutor em Ciências
557

Síntese de monômero ácido alternativo para composição de sistemas adesivos autocondicionantes / Synthesis of an alternative acidic monomer for the preparation of self-etch adhesive systems

MUNCHOW, Eliseu Aldrighi 13 March 2014 (has links)
Made available in DSpace on 2014-08-20T14:30:19Z (GMT). No. of bitstreams: 1 Dissertacao_eliseu_aldrighi_munchow.pdf: 1202368 bytes, checksum: 1ae7600de25d0a152376ee755126653c (MD5) Previous issue date: 2014-03-13 / The aim of this study was to synthesize a new acidic monomer (polypropylene glycol methacrylate phosphorous Poly-P) to constitute an experimental two-step self-etch adhesive system and to evaluate its influence on the pH of different self-primers and on the microshear bond strength (&#956;SBS) to enamel. Four experimental self-etch primers containing Poly-P (10, 15, 30 or 50 wt%), 2-hydroxyethyl methacrylate (HEMA), ethanol and water were formulated. A control primer (referential) and a commercial one (Clearfill SE Bond) were also used. The self-primers were allocated in two subgroups according to a buffered and a non-buffered pH. A microshear bond strength (&#956;SBS) test protocol was performed at the enamel substrate, followed by the mechanical testing (EMIC). Scanning Electron Microscopy (SEM) was performed in the enamel surfaces after the self-primers application. The &#956;SBS results were analyzed by One-Way Kruskall-Wallis test and Student-Newman-Keuls as post hoc test (p<0.05). As greater the Poly-P concentration, the lower the pH of the self-primers. The self-primers with a buffered pH resulted in the lowest &#956;SBS values, while the non-buffered self-primers with Poly-P amount higher than 15 wt% showed the highest bond strength results, and similar to the control/referential adhesive systems used. The SEM images demonstrated that the self-primers with high Poly-P content (30 and 50 wt%) resulted a Type 1 etching pattern in the enamel surface. The pH of the self-primer was directly influenced by the acidic monomer concentration, which has directly affected the enamel bond strength results. The Poly-P is a potential monomer to be used in the formulation of self-etch dental adhesive systems / O objetivo deste estudo foi sintetizar um novo monômero ácido (metacrilato de polipropileno glicol fosfatado (Poli-P) para constituir um sistema adesivo autocondicionante experimental e para avaliar a sua influência no pH de diferentes primers autocondicionantes e na resistência de união ao esmalte. Quatro primers autocondicionantes experimentais contendo Poli-P (10, 15, 30 ou 50% em massa), metacrilato de 2-hidroxietila (HEMA), etanol e água foram formulados. Um primer controle (referencial) e um primer comercial (Clearfill SE Bond) também foram utilizados. Os primers foram divididos em dois grupos de acordo com o pH: um grupo com pH tamponado (=2,0) e o outro sem. Um protocolo para o teste de resistência de união ao microcisalhamento (RM) foi realizado em esmalte humano, seguido do teste mecânico (EMIC). Microscopia Eletrônica de Varredura (MEV) foi realizada nas superfícies de esmalte após a aplicação dos primers autocondicionantes, para caracterização do padrão de condicionamento. Os dados foram analisados com Kruskal-Wallis uma via e o teste complementar de Student Newman Keuls (p<0,05). Quanto maior a concentração de Poli-P, menor o pH dos primers. Os primers com pH tamponado resultaram nos menores valores de RM, enquanto que os primers sem tamponamento e com concentração superior a 15% de Poli-P mostraram os maiores valores de união, e similares aos grupos controles. As imagens em MEV demonstraram que os primers com elevado conteúdo de Poli-P (30 e 50%) resultaram em um padrão do tipo 1 de condicionamento da superfície do esmalte. O pH dos primers autocondicionantes foi influenciado diretamente pela concentração do monômero ácido, o qual foi afetado diretamente pelos resultados de resistência de união. O Poli-P é um novo monômero com potencial utilização na formulação de sistemas adesivos dentários autocondicionantes
558

Efeito da técnica restauradora, do tipo de preparo e do envelhecimento de restaurações de resina composta sobre a resistência à fratura dental, resistência adesiva e vedamento marginal / Restorative technique, kind of prepair and aging effects on composite resin restorations fracture strength, restoration retention and marginal adaptation

Souza, Fábio Herrmann Coelho de 23 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:20Z (GMT). No. of bitstreams: 1 Tese - Fabio Herrmann.pdf: 2352205 bytes, checksum: a6bcc0f4e7708f23fde2f31a66c02b83 (MD5) Previous issue date: 2006-06-23 / The aim of this study was to evaluate, in vitro, the effect of composite resin restoration techniques, bevel and storage time on the fracture strength, restoration retention and gap formation. For the fracture strength test, standard MOD cavities were prepared in 100 upper premolars, which were divided in two storage times (24 hours and 6 months with 1000 thermocycles), and in each group, sub-groups were randomly formed as follow: group 1 direct composite resin restoration(Filtek Z250 and Adper Single Bond 3M/ESPE) without bevel (butt joint); group 2 beveled direct composite resin restoration; group 3 indirect composite resin inlay (Z250 and Rely X ARC 3M/ESPE) without bevel(butt joint); group 4 beveled indirect composite resin inlay; group 5 sound teeth; group 6 teeth with MOD preparations (no restorations). For the retention test, the incisal edge of 90 lower incisors was sectioned, and divided in the same restorative groups as described above (except group 6). To evaluate gap presence or absence, proximal box cavities were prepared in 24 human third molars, which were restored with direct or indirect composite restorations, with or without bevel, similar to above described and examined under SEM evaluation. Data was statistically analysed by A NOVA, Tukey and t-student tests for fracture strength and retention tests, and Fisher s exact test for gap formation (=0,05). At the 24 hours, beveled restorations exhibited higher fracture strength values than non beveled restorations and most of the tested groups showed resistance similar or superior than sound teeth. After 6 months, the best results were obtained for beveled inlays and the worst values were observed for butt joint direct restorations. In the retention test,beveled restorations had superior performances than non-beveled restorations, in both periods of time. For both tests, a 6-month storage time and thermal cycling produced significant properties decrease in groups 1, 2 and 4 showed. Under SEM examination, no difference was observed among groups after 24 hours. However,after 6 months, beveled restotations remained without gap formation and they had better performance than butt joint restorations. Pearson correlation test showed positive correlation between fracture strength and retention tests. Within the limitations of the study, it was concluded that aging impaired adhesive properties, bevel improved the performance in all tests and generally indirect restorations were not superior to direct restorations. / O objetivo do presente trabalho foi avaliar in vitro o efeito da técnica restauradora, da confecção de bisel e do tempo de armazenamento de restaurações de resina composta sobre a resistência à fratura dental, resistência à fratura de restaurações (resistência adesiva) e formação de fenda marginal. Para o teste de resistência à fratura dental, foram utilizados 100 pré-molares superiores, submetidos a preparos cavitários MOD, divididos em 2 tempos de armazenamento (24 horas e 6 meses com termociclagem 1000 ciclos), subdivididos nos seguintes grupos: grupo 1 restaurados com resina composta direta (Filtek Z250 e Adper Single Bond 3M/ESPE) sem bisel; grupo 2 resina composta direta com bisel; grupo 3 resina composta semi-direta (Z250 e Rely X ARC 3M/ESPE) sem bisel; grupo 4 resina composta semi-direta com bisel; grupo 5 dentes hígidos; e grupo 6 dentes apenas preparados (n=10). Para o teste de resistência à fratura de restaurações, foram utilizados 90 incisivos inferiores, que receberam desgaste do bordo incisal e foram divididos nos mesmos grupos citados acima (exceto o grupo 6). Para a avaliação de presença ou ausência de fenda marginal,foram empregados 24 terceiros molares, que receberam preparos proximais, divididos nos mesmos grupos acima (exceto os grupos 5 e 6). Os dados foram submetidos à análise estatística (=0,05) através dos testes ANOVA, Tukey e t-student para resistência à fratura dental e resistência à fratura de restaurações e teste exato de Fisher para formação de fenda marginal. Os resultados mostraram que, para resistência à fratura dental, no tempo de 24 horas, as restaurações com bisel foram superiores às demais, enquanto as sem bisel não diferiram dos dentes hígidos. Após 6 meses, as restaurações semi-diretas com bisel foram superiores às demais, não diferindo das semi-diretas sem bisel; as restaurações diretas sem bisel foram inferiores às demais. Para resistência à fratura de restaurações, as restaurações com bisel foram superiores às demais para ambos os tempos de armazenamento, e não diferiram dos dentes hígidos em 24 horas. Para os 2 testes citados, os grupos 1, 2 e 4 apresentaram redução significativa do seu desempenho após 6 meses de armazenamento e termociclagem. A avaliação de fenda em esmalte mostrou que em 24 horas não houve diferença entre os grupos. Após 6 meses, as restaurações com bisel continuaram livres de fenda, enquanto as sem bisel apresentaram fenda na maioria dos espécimes. A análise de correlação de Pearson mostrou resultado significativamente positivo para os 2 testes de resistência. Concluiu-se que o tempo de armazenamento e termociclagem foram fatores significativos na redução da performance adesiva; a realização de bisel influenciou de forma positiva na melhora do desempenho das restaurações em todos os testes empregados; as restaurações semi-diretas de resina composta, de modo geral, não foram superiores às diretas.
559

Interação com o maciço de modelos estruturais de concreto projetado submetidos a gradientes elétricos para fins de suporte de túneis / Interaction of ground mass and shotcrete structural models subjected to electric gradient for tunnel support

Danieli Aparecida Ferreira 10 September 2003 (has links)
Esta pesquisa apresenta os resultados obtidos com o emprego de um método físico para aumento da resistência de concretos projetados a pequenas idades. O método consiste na aplicação de gradientes elétricos ao material logo após a projeção, sendo mantido nas primeiras 5:30 h de hidratação. O comportamento mecânico do concreto projetado submetido a gradientes elétricos foi analisado em termos da resistência à compressão e módulo de elasticidade a partir da resposta de modelos estruturais e de amostras extraídas de estruturas projetadas em diferentes idades. Os modelos estruturais foram desenvolvidos para simular esforços ao concreto projetado semelhantes àqueles resultantes da interação solo-suporte em obras subterrâneas. A projeção do concreto nestes modelos ocorreu diretamente sobre o solo, permitindo assim a análise da eficiência do método sob condições de fuga de corrente elétrica para o maciço em diferentes tipos de solos. A instrumentação destes modelos permitiu analisar a eficiência do método sobre a deformabilidade do concreto projetado, sendo medidas as evoluções de deformações elásticas e deformações de fluência ao longo do tempo bem como deformações independentes de tensões desde as primeiras horas de hidratação. Constataram-se acréscimos na resistência nas primeiras 8 h de idade do concreto projetado em projeção sobre placas de madeira e diretamente sobre o solo. O módulo de elasticidade obtido a partir da instrumentação da resposta instantânea ao carregamento também constatou melhorias pela aplicação do gradiente elétrico. A reologia do concreto projetado, a partir das parcelas de deformações instantânea, retardada e lenta foi analisada utilizando-se o modelo proposto por SCHUBERT (1988). Melhorias foram observadas na resposta em termos de deformações do concreto projetado quando submetidos ao gradiente elétrico, apresentando menores taxas de evolução de deformações lentas em resposta a carregamentos iniciados em idades inferiores a 10 h e redução da parcela de deformação permanente frente ao descarregamento. A investigação dos fatores que provocam acréscimos na resistência a pequenas idades pela aplicação de gradientes elétricos a pastas e argamassas foi realizada utilizando-se técnicas de Microscopia Eletrônica de Varredura e Difratometria de Raio X. Constataram-se alterações na microestrutura de argamassas submetidas a gradiente elétrico, sem alteração nos compostos hidratados. Alterações na taxa de hidratação foram evidenciadas pela comparação de padrões difratométricos entre pastas submetidas a gradientes elétricos e pastas de referência. / This work presents the results obtained by employing a physical method for the strength increase of shotcrete at early age. The method consists of applying electric gradient to the material during the first 5 hours and 30 minutes of hydration, starting immediately after spraying. The mechanical behavior of shotcrete subjected to electric gradient was evaluated at different ages in terms of unconfined compressive strength and elastic modulus obtained from the response of structural models and on samples cored from the structural models. Shotcrete structural models were constructed in order to simulate internal forces resulting from ground mass - support interaction in underground works. Shotcrete in these models was sprayed directly on soil. It was thus possible to analyse the efficiency of the method when leakage currents occur through the soil. Model instrumentation alloed to evaluate the method efficiency in terms of shotcrete deformability. The evolution of elastic and creep strains were evaluated, as well as stress-independent strains since the beginning of hydration. Strength increase during the first 8 hours of age were observed both on panels shotcreted on wooden forms and directly on soil. The elastic modulus was also obtained from the analysis of the instantaneous strain reponse to the applied load. Improvement due to electric gradient was also found this way. Shotcrete rheology in terms instantaneous, delayed and creep strains was analyzed adopting the model proposed by SCHUBERT (1988). Improvement due to the electric gradient was found with respect to each of those strain components resulting from load applied at ages lower that 10h. Permanent strain after unloading was also reduced. The investigation of the phenomena responsible for the strength increase at early age due to the application of electric gradient to cement paste and mortar was carried out with the techniques of scanning electron microscope and X-ray diffraction. Microstructure changes were found in mortar speciments subjected to electric gradient, however without any change of hydrated products. Hydration rate changes were detected from diffractometric patterns of cement pastes subjected to electric gradient.
560

Análise microestrutural em altas temperaturas de um ferro fundido branco de alto cromo com molibdênio e nióbio / A molybdenum and niobium high chromium white cast iron study-metallography at high temperatures

Cloir Salatiel da Silva 15 October 1999 (has links)
As mudanças microestruturais, causadas pela adição de elementos de liga e pelos tratamentos térmicos, modificam as propriedades mecânicas e tribológicas dos materiais. Foi desenvolvido então um estudo em amostras de um ferro fundido branco de alto cromo com molidbênio e nióbio, procurando determinar os efeitos dos elementos de liga molibdênio e nióbio, na microestrutura deste material, através de medidas de dureza, dilatometria, ataque químico, microscopia eletrônica de varredura e,principalmente, a utilização de metalografia em altas temperaturas. A técnica de metalografia em altas temperaturas permite o estudo das mudanças microestruturais durante os ciclos térmicos, que foram programados, tendo como referência a curva TTT previamente traçada para este material, focalizando regiões onde não ocorrem mudanças de fase. Deste modo foram obtidas as aparências metalográficas em altas temperaturas e feito um estudo comparativo com as outras técnicas usadas. Com isto é possível melhorar o conhecimento sobre a microestrutura do material em questão e obter ligas com propriedades pré-determinadas. / The microstructural changes caused by the addition of alloying elements and by thermal treatments modify the mechanical and tribological properties of the materials. A study was develop on samples of molybdenum and niobium high chromium white cast iron, trying to determine the effects of molybdenum and niobium alloys elements on microstructure of this material through hardness measurements, dilatometry, chemical etching, scanning electron microscopy, and mainly, utilizing metallography at high temperatures. The metallography at high temperatures technic allows the study of microstructural changes during the thermal cyc1es, which were scheduled, having as reference the TTT curve previously traced to this material, focusing regions where changes of fase don\'t occur. So the metallographic appearances at high temperatures were obtained and it was done a comparative study using other technics. Because of that is possible to improve the knowledge of the material microstructure, which it has been studied, and to obtain alloys with predetermined properties.

Page generated in 0.1055 seconds