• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 39
  • 39
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Blendas de poli (oxido de etileno) com poli (epcloridrina) e com poli (epicloridrina-co oxido de etileno) : comportamento de fases, miscibilidade e morfologia

Silva, Márcia Aparecida da 20 July 2018 (has links)
Orientadores : Maria Isabel Felisberti, Marco-Aurelio De Paoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-20T03:05:36Z (GMT). No. of bitstreams: 1 Silva_MarciaAparecidada_M.pdf: 3081971 bytes, checksum: a912680981aca4ac6b7f93d486f49161 (MD5) Previous issue date: 1995 / Mestrado
22

Estudo do fluxo gerado por agitadores tipo ancora

Rudinger, Antonio Carlos de Andrade 08 January 2002 (has links)
Orientador: Jose Roberto Nunhez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-02T04:59:05Z (GMT). No. of bitstreams: 1 Rudinger_AntonioCarlosdeAndrade_M.pdf: 2677684 bytes, checksum: 5c4642641223b8c95f62ef0007f20f98 (MD5) Previous issue date: 2002 / Resumo: Agitação e mistura são o coração da indústria química, e provavelmente os equipamentos para esses fins são os mais antigos que se possa imaginar quando se fala em processamento de matérias primas visando-se a obtenção de produtos. Devido à sua grande importância para a indústria, os processos vem se desenvolvendo ao longo do tempo e, nas últimas décadas, técnicas computacionais tem sido utilizadas para o projeto e otimização desses equipamentos. Em especial destaca-se a fluido-dinâmica computacional - CFD (Computational Fluid Dynamics). Este trabalho tem como objetivo a aplicação de técnicas de CFD para o estudo de sistemas com agitadores tipo âncora, utilizados em geral para fluidos altamente viscosos e, portanto com alto consumo de energia. O estudo por sua vez, através do entendimento dos fluxos no interior do tanque, tem como objetivo propor soluções e modificações a fim de melhorar a mistura e minimizar o gasto de energia no processo. O pacote computacional CFX 4.4. foi empregado como ferramenta de CFD para a realização dos estudos contidos neste trabalho, tendo sido obtidos resultados esclarecedores dos fenômenos envolvidos e coerentes com os dados experimentais disponíveis em literatura. Conclui-se que as ferramentas utilizadas são apropriadas para o estudo de tanques agitados e que possibilitam tanto o projeto como também a otimização de sistemas existentes, com economia de tempo e dinheiro. Quando comparada à técnicas experimentais, a técnica provou fornecer resultados precisos e confiáveis. A sugestão para estudos futuros é o cálculo simultâneo de reações químicas, para o entendimento de reatores químicos, especialmente em reações onde a viscosidade varia com o tempo / Abstract: Stirred vessels and mixing systems are the core of the chemical industries, and probably they are the oldest equipment in chemical processing for desired products. Due its great importance to the industry, these processes have been developed through the time, and in the last decades, computational techniques have been used in the project and optimization of these equipments. Particularly the Computational Fluid Dynamics - CFD. The objective of this work is to apply CFD techniques in the study of systems agitated by anchor impellers, generally used for higWy viscous fluids and therefore with high power consumption. The study has the objective to propose changes in the system so mixing can be optimized and the power consumption minimized, through the understanding of the flow pattems inside the tank. The computational package CFX 4.4. has been used as a CFD tool to generate the numerical results, which are useful to clarify the phenomena and are coherent with experimental data available in the literature. The study showed that the tools that have been used are appropriated to the study of stirred vessels and are able to design new systems and optimize actual systems, leading to money and time saving. .When compared to experimental techniques, the tools used showed that it is able to provide precise and reliable results. The suggestion for future studies is the simultaneous calculus of chemical reactions, which can lead to a better understanding of chemical reactors, especially those in which viscosity varies along time / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
23

Estudo tribologico de hidrogeis polimericos para serem utilizados como cartilagem articular artificial / Tribological study of polymeric hydrogels for use as artificial articular cartilage

Bavaresco, Vanessa Petrilli, 1971- 26 July 2004 (has links)
Orientadores: Cecilia Amelia de Carvalho Zavaglia, Marcelo de Carvalho Reis / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T01:42:37Z (GMT). No. of bitstreams: 1 Bavaresco_VanessaPetrilli_D.pdf: 14276021 bytes, checksum: d5ab24900afcc34fe160b1d9a55fa2bd (MD5) Previous issue date: 2004 / Resumo: O desenvolvimento de próteses articulares com superfície complacente, capaz de favorecer ou permitir a lubrificação entre os componentes das juntas artificiais, como acontece nas juntas naturais, vem despertando grande interesse visto que diminui o coeficiente de atrito entre as superfícies, favorecendo o deslizamento entre as mesmas e minimizando o desgaste. A proposta deste trabalho foi estudar e melhorar as propriedades mecânicas de hidrogéis poliméricos de poli (metacrilato de 2-hidroxietila) (pREMA) e poli (álcool vinílico) (PVA) reconhecidamente utilizados no estudo de reparadores da cartilagem articular natural. Para tanto foram obtidos copolímeros de pREMA e n-vinil pirrolidona (NVP) (polímero hidrofílico de reforço) variando-se a concentração de agente de reticulação e blendas de poliHEMA com o copolímero poli(metacrilato de metila-co-ácido acrílico) (75:25) enquanto que, os hidrogéis a base de poli (álcool vinílico) foram reticulados com radiação ionizante de feixe de elétrons. O estudo envolveu a caracterização térmica, mecânica e morfológica desses materiais bem como sua caracterização quanto ao desgaste em um equipamento do tipo PIN-ON-DISK com uma contra-superficie de metal em condições próximas à fisiológica com movimento relativo rotativo e, ainda, com movimento recíproco ou alternado / Abstract: There is an increasing interest in the development of soft layered articular prostheses, which favour sliding between components, as natural joints do, thus reducing contact stresses and wear. The purpose of this work was to characterize and improve the mechanical properties of poly (2-hydroxyethyl metacrylate) (pHEMA) and polyvinyl alcohol (PVA) hydrogels. These hydrogels are extensively studied for articular cartilage repair. Samples of pHEMA and n-vinyl pirrolidone (NVP) copolymers with different amounts of trimethylol propane trimethacrylate (TMPTMMA) crosslinking agent, and samples of pHEMA/poly (methyl metacrylate-co-acrylic acid) blends were prepared by thermal polymerization. Additionally, PVA based hydrogels were prepared by means of electron beam ionizing radiation. Hydrogel samples were characterized by indentation creep test, equilibrium water content (EWC) and Differential Scanning Calorimetry (DSC). The tribological characterization of hydrogels was performed under nearly looading physiological conditions at room temperature on a pin-on-disc equipment, Plint TE67, using a stainless steel 316L disc counter surface / Doutorado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
24

Efeitos em misturas gasosas de tricloreto de boro e etileno ocasionados por : 1) radiação infravermelha de um laser CO2 pulsado, 2) descargas eletricas, 3) aquecimento

Pessine, Francisco Benedito Teixeira, 1948- 17 July 2018 (has links)
Orientador : Chhiu-Tsu Lin / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-17T01:02:08Z (GMT). No. of bitstreams: 1 Pessine_FranciscoBeneditoTeixeira_D.pdf: 12649446 bytes, checksum: 2274e156be876bbb00f3b5ac03e8f718 (MD5) Previous issue date: 1980 / Doutorado
25

Interação entre modelos de membrana biológica e poluentes emergentes /

Maximino, Mateus Dassie. January 2018 (has links)
Orientador: Priscila Alessio Constantino / Banca: Amando Siuiti Ito / Banca: Eloi da Silva Feitosa / Resumo: O presente trabalho trata do estudo da interação entre os poluentes emergentes amoxicilina (AMX) e azul de metileno (AM) com modelos-simples de membrana biológica compostas de fosfolipídios zwiteriônicos (DPPC e DOPC), através de filmes de Langmuir e vesículas unilamelares gigantes (GUVs). As membranas foram expostas aos poluentes de forma individual e também misturados (MIX) para que se aproximasse de uma situação real, neste caso, o chamado efeito coquetel, no qual os poluentes são encontrados misturados no ambiente. O objetivo principal foi investigar as possíveis interações entre os poluentes e os fosfolipídios e os consequentes efeitos nas membranas. Nos filmes de Langmuir, as isotermas π-A (pressão superficial por área molecular média) de DPPC revelaram que a AMX e o AM são expulsos da interface ar-água conforme a fase condensada é atingida. O DOPC demonstrou ser menos afetado pela AMX, uma vez que a isoterma não apresentou deslocamento. Contudo, o DOPC se mostrou mais susceptível a interagir com o AM, visto que um deslocamento significativo foi observado. Para ambos os lipídios a MIX causou maiores efeitos, evidenciados por deslocamentos maiores nas isotermas. Análises de módulo compressional mostraram um pequeno aumento na fluidez do filme de DPPC, não observado para o DOPC. As medidas de microscopia de ângulo de Brewster (BAM) na presença dos poluentes revelaram mudanças na morfologia dos filmes, afetando a formação dos domínios de DPPC e impedindo a formação dos mes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present work is about the interaction between the emerging pollutants amoxicillin (AMX) and methylene blue (MB), with biological membrane models of zwitterionic phospholipids (DPPC and DOPC), through Langmuir films and giant unilamellar vesicles (GUVs). The membrane was exposed to the presence of the pollutants individually, still being performed the analysis with the mixture (MIX) of both in order to get closer to a real situation, in which the pollutants are found mixed in the environment. The main goal was to investigate the possible interactions between the pollutants and phospholipids. The π-A (surface pressure by mean molecular area) isotherms of DPPC reveal that in the condensed phase the lipid expelled the AMX and MB of the air-water interface. The DOPC showed to be less affected by the AMX, once the isotherm did not present a displacement. However, the DOPC showed to be more susceptible to interact with the MB, since significant displacements were observed. In both lipids, the MIX showed to be more effective, causing bigger displacements. The analysis of compressional modulus showed a small increase of the fluidity of the DPPC film, which was not observed to the DOPC. The Brewster Angle Microscopy (BAM) measurements in the presence of the pollutants revealed changes in the morphology, affecting the domains formation of DPPC and inhibiting the formation of the same in monolayers. The PM-IRRAS specters to the DPPC indicated possible electrostatic interactions with ... (Complete abstract click electronic access below) / Mestre
26

Obtenção e caracterização de blendas de poli(p-dionanona)/poli(L-acido lactico) (PPD/PLLA) para aplicação como protese de menisco bioreabsorvivel

Pezzin, Ana Paula Testa 20 April 2001 (has links)
Orientação: Eliana Aparecida de Rezende Duek / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-31T14:51:49Z (GMT). No. of bitstreams: 1 Pezzin_AnaPaulaTesta_D.pdf: 25817091 bytes, checksum: 25a24f838427f3546f948d3904de6947 (MD5) Previous issue date: 2001 / Resumo: Nos últimos anos, os polímeros bioreabsorvíveis ganharam uma importância crescente na área médica, devido às suas características de bioreabsorção e biocompatibilidade. Com o intuito de se obter um material polimérico adequado para aplicação como prótese de menisco, estudou se a obtenção e caracterização de blendas bioreabsorvíveis de poli( ácido L-Iáctico) (PLLA) e poli(p-dioxanona) (PPD) preparadas por evaporação de solvente e fusão. As blendas foram caracterizadas por calorimetria diferencial de varredura modulada (MDSC), microscopia eletrônica de varredura (MEV), microscopia óptica (MO), ensaios mecânicos de tração, diftação de raios-X, análise dinâmico-mecânica (DMA) e calorimetria diferencial de varredura (DSC). As análises térmicas indicaram que as blendas são imiscíveis, pois todas as composições apresentaram duas temperaturas de transição vítrea próximas dos polímeros puros. Foi observado por MEV e MO, uma maior homogeneidade nas composições 20/80 e 80/20, enquanto as blendas 40/60, 50/50 e 60/40 apresentaram uma nítida separação de fases. As blendas foram degradadas in vitro em solução tampão fosfato (pH = 7,4) a 37 :f: 0,5 °C e analisadas por DSC, análise termogravimétrica (TGA) e MEV. Através do estudo in vitro, verificou-se que a PPD degrada mais rápido que o PLLA e que as blendas apresentam comportamento intermediário entre os homopolímeros, mostrando que é possível acelerar a degradação do PLLA através da adição de PPD à blenda. O estudo permitiu a escolha da blenda PPDIPLLA 80/20 como a mais adequada para o implante. Foi realizado um estudo in vivo em coelhos com a blenda porosa PPDIPLLA 80/20 com 3% de trieti! citrato de sódio. Os coelhos foram submetidos a meniscectomia total do menisco medial e as próteses foram retiradas após 3, 6, 12, 14 e 15 semanas. O material foi observado por MO e MEV. O estudo in vivo mostrou que após 14 semanas foi possível observar fibrocartilagem, indicando que a blenda estudada apresenta grande potencial para ser utilizada para a aplicação em questão, já que o material favorece a formação de um neomenisco / Abstract: In the last years, the bioreabsorbable polymers have been gained an increased importance in the medical field, due to its charactheristics of bioreabsorbability and biocompatibility. In order to obtain a polymeric material adequated to be used as meniscus prosthesis, bioreabsorbable blends of poly (L-lactic acid) (PLLA) and poly-p-dioxanone (PPD) have been prepared by solvent casting and melting processo The blends were studied using modulated differential scanning calorimetry, scanning electron microscopy, optical microscopy, tensile tests, x-ray diffractometry, dinamical mechanical analysis and differential scanning calorimetry (DSC). Thennal analysis showed two glass transition temperatures nearly constant and equal to the pure polymers for all blend compositions, suggesting that both polymers are immiscible. The 20/80 and 80/20 blends presented better homogeneity, while 40/60, 50/50 and 60/40 compositions presented a clearly macrosepared system. Blends were immersed in tubes containing a phosphate buffer solution (pH = 7,4) in a thermally controlled bath of 37 :t: 1°C and studied by DSC, thennogravimetric analisys (TGA) and scanning electron microscopy. It was observed by in vitro study that PLLA has a slower degradation rate than PPD and the blends presented an intennediated degradation rate, showing that is possible to vary the degradation rate of the blend changing its composition. The in vitro study was important to permit the choice of the 80/20 blend as the more adequated to implant. An in vivo study was perfonned in rabbits with the porous blend PPD/PLLA (80/20) containing 10 wt % of polymer and 3 wt % of sodium trietil citrate. Meniscectomy was made in rabbits, and the prosthesis were retired after 3,6, 12, 14 and 15 weeks intervals. The samples were observed by scanning electron microscopy and optical microscopy. The in vivo study showed that after 14 weeks it was possible to observe fibrocartilage, suggesting that this material has great potential to be used as meniscal prosthesis due to the induced fonnation of a meniscal replic / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
27

Desenvolvimento e otimização de misturador estatico com o uso da fluidinamica computacional (C.F.D.) / Development and optimization of a statistic mixer with the use of computational fluid dynamics (C.F.D.)

Joaquim Junior, Celso Fernandes, 1971- 29 May 2008 (has links)
Orientadore: Jose Roberto Nunhez, Efraim Cekinski / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-11T21:24:27Z (GMT). No. of bitstreams: 1 JoaquimJunior_CelsoFernandes_M.pdf: 1822240 bytes, checksum: 1c74330095d87b01b823d7d17fbc50c9 (MD5) Previous issue date: 2008 / Resumo: Nos processos convencionais de agitação e mistura um acionamento, através de um eixo-árvore, rotaciona um ou mais impelidores no interior de um fluido, normalmente contido em um vaso de processo. Os processos de mistura que usam dispositivos estáticos no interior de dutos de escoamento são uma opção aos processos convencionais, tendo crescente aplicação e interesse, visto utilizar-se de parte da energia cedida para o bombeamento dos fluidos, permitindo a mistura em um processo contínuo, minimizando o uso de equipamentos e instalações industriais. Contudo, sua aplicação ainda é restrita a alguns processos específicos por questões tecnológicas e, principalmente, pelo pouco conhecimento de técnicos e engenheiros dos fenômenos físicos que regem sua aplicabilidade. A inexistência de tecnologia e conhecimento nacional nesta área impõe a dependência frente a empresas estrangeiras, encarecendo e dificultando sua aplicação. Na última década, técnicas computacionais tem sido utilizadas para o projeto e otimização desses dispositivos, conhecidos como misturadores estáticos, com destaque para a fluidodinâmica computacional ¿ CFD (Computational Fluid Dynamics). Este trabalho tem como objetivo, através da aplicação de técnicas de CFD, permitir um melhor entendimento dos fenômenos que regem o escoamento de fluidos no interior de misturadores estáticos, especificamente desenhados para esta análise, permitindo sugerir e estudar seus desenhos, propondo soluções e modificações a fim de melhorar a mistura e minimizar o gasto de energia no processo. A ferramenta de CFD utilizada foi o pacote computacional CFX. Os resultados obtidos permitiram uma boa compreensão dos fenômenos envolvidos e foram coerentes com os dados experimentais disponíveis na literatura. Foram criados dois novos conceitos geométricos de misturadores estáticos, denominados de EDA e ALETAS, cujas performances permitem seu emprego em condições reais de aplicação na indústria. / Abstract: On conventional mixing processes, a shaft rotates one or more impellers in a fluid generally inside a process vessel. The mixing processes that use static mixers on tube fluid flow are an option to conventional processes which application and interest is continuously growing, minimizing the use of equipment industrial devices. However its application is restricted to some specific processes because of technological reasons and mainly due to the lack or absence of acknowledgement of technicians and engineers about the physical phenomena involved on static mixing application. The absence of national technology on this field, demands foreign companies¿ technological dependence, making more difficult more and turning expensive the applications. On the last decade, computational techniques have been used for the design and optimization of these equipments, known as static mixers, specially the computational fluid dynamics ¿ CFD. This research has the goal, by using CFD techniques, to allow a better understanding of the phenomena that determine the fluid flow in static mixers specifically designed for this analysis, permitting to study and suggest modifications and solutions to increase mixing and minimize power consumption on the process. The CFD tool used was the CFX package. The results obtained permitted a good comprehension of the phenomena involved and were in accordance with experimental data available on literature review. Two new geometric concepts of static mixers were created, named EDA and ALETAS, whose performances allow their use on industrial applications. / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
28

Mistura diesel, biodiesel e etanol anidro : uma possibilidade para reduzir o custo de produção da cadeia da cana-de-açúcar / Blending diesel, biodiesel and ethanol anhydrous : is a possibility to reduce the cost of the production chain of sugar cane

Moretti, Ricardo Roquetto, 1982- 23 August 2018 (has links)
Orientador: Waldir Antonio Bizzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-23T09:38:07Z (GMT). No. of bitstreams: 1 Moretti_RicardoRoquetto_M.pdf: 3138518 bytes, checksum: 3ee2db245fb6caad13e782dc3c9072a2 (MD5) Previous issue date: 2013 / Resumo: A emissão de poluentes por veículos automotores é um dos grandes problemas ambientais enfrentados na atualidade. Para resolver o problema de emissão de poluentes à modificação da matriz energética foi o caminho adotado, e para isso realizaram-se investimentos em tecnologias para fabricação de motores com melhor eficiência térmica e capazes de operar com biocombustíveis. No Brasil etanol foi o combustível objeto de estudo para realizar a mudança na matriz energética, por ser um produto produzido em larga escala no Brasil. Durante o estudo realizou-se uma revisão bibliográfica sobre os processos de produção de etanol, biodiesel e óleos vegetais. Avaliou-se a viabilidade técnica e financeira de se utilizar uma mistura de combustível óleo diesel, biodiesel versus o desempenho da mistura óleo diesel, biodiesel e etanol anidro em um motor de ignição por compressão visando não acarretar perda de performance no motor. Para a avaliação do desempenho global do motor utilizou-se um motor ciclo diesel comercial, operando com 95% de óleo diesel e 5% biodiesel e comparou-se esse mesmo motor utilizando uma mistura de 92,15% de óleo diesel, 4,85% de biodiesel e 3% de etanol anidro / Abstract: This work investigated the feasibility of using a blend of standard Brazilian diesel (which contains 5% biodiesel) and up to 5% ethanol. We characterized the mixture as fuel and measured the performance of a diesel engine operating with a blend containing 3% anhydrous ethanol, the maximum percentage of ethanol that did not reduce the cetane number of the fuel below that specified in Brazilian legislation (ANP Resolution 42). The presence of anhydrous ethanol in the mixture did not cause a significant impact on engine performance as measured by brake power, brake torque and brake specific fuel consumption tests. The thermal efficiency of the engine used in the tests was slightly higher with standard diesel than with the diesel-biodiesel-ethanol blend / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
29

Consumo de potência para impelidores rápidos aplicados em processos de agitação e mistura / Power consumption of high shear impellers in processes of agitation and mixture

Souza, Edimilson 11 August 2011 (has links)
Orientador: José Roberto Nunhez / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T04:29:50Z (GMT). No. of bitstreams: 1 Souza_Edimilson_D.pdf: 42879503 bytes, checksum: f045a81ccffc27a6b322cd000bb460cd (MD5) Previous issue date: 2011 / Resumo: O projeto de agitadores envolve um grande número de variáveis, além da necessidade de utilização das relações empíricas para que se possa elaborar um projeto eficiente. Em função do grande número de variáveis envolvidas, muitas opções ainda carecem de estudos científicos e bibliografias que deem segurança aos projetistas, como é o caso dos impelidores do tipo disco dispersor, para altas dispersões, com característica predominantemente de alto cisalhamento, também conhecidos como: impelidores dentados, dentes de serra ou simplesmente Cowles. O estudo passa inicialmente pelo entendimento amplo dos conceitos de agitação e mistura, tais como: regime de escoamento em tanques agitados, fluidos, nível de agitação, processos de agitação e mistura, geometrias de tanques, tipos e geometria dos impelidores, número de bombeamento e número de potência. Comparou-se resultados de número de potência obtidos nos ensaios com teoria de autores consagrados para impelidores de pás retas. Obteve-se de forma experimental as equações do torque em função da rotação e as curvas do número de potência em função do número de Reynolds para impelidores do tipo disco dispersores de diversas geometrias, trabalhando com dois métodos de medição de torque: transdutor de torque e parâmetros elétricos, utilizando unidade piloto de 50 e 1000 L, assim como indica o número de potência determinado para oitenta e oito impelidores ensaiados / Abstract: The design of impellers involves a great number of variables, as well as the use of empirical correlations to enable an efficient design. Due to the great number of variables involved, many design options lack a deeper scientific basis and broader literature information that would provide the engineer with a more understanding to elaborate a more efficient design. This is the case for impellers used in dispersions, where the main impeller characteristic are their high shear. These impellers are also known as toothed impellers or Cowles impellers. This study starts with the acquiring of a deeper understanding of .mixing processes using high shear impellers with the corresponding concepts of agitation level, tank geometry, impeller geometry, Pumping and Power numbers. The Power number obtained in this work was compared with the published results of previous authors for flat blade impellers. The correlations for torque as a function of impeller speed and the Power number for several impeller disperses as a function or Reynolds number were obtained through a torque transducer and electrical parameters using both a 50 L and a 100 L pilot plants. The experimental Power number of eighty eight impellers was determined in this work / Doutorado / Processos em Tecnologia Química / Doutor em Engenharia Química
30

Estudo da biodegradação da blenda de poli (e-caprolactona) e amido modificado em meios solido e liquido

Mariani, Pilar Drummond Sampaio Correa 05 June 2005 (has links)
Orientadores: Lucia Helena Innocentini Mei, Elisa Esposito / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-04T07:23:57Z (GMT). No. of bitstreams: 1 Mariani_PilarDrummondSampaioCorrea_M.pdf: 4205251 bytes, checksum: 489736fab0d98a4f88502814456a5e50 (MD5) Previous issue date: 2005 / Resumo: A consciência ambiental crescente, somada às políticas de gerenciamento de resíduos sólidos, tem impulsionado o desenvolvimento de materiais biodegradáveis par a substituição parcial dos plásticos de origem petroquímica em algumas áreas estratégicas como a de embalagens. No presente trabalho, avaliou-se a biodegrabilidade da blenda de PCL/Amido adipatado em solo, se acordo com a norma ASTM D5988-96 e Anderson et al. (1982); e em meio liquido de acordo com a norma ASTM 6691-01e Mergaert et al. (2000). No teste realizado em solo, a biodegradação foi acompanhada pela determinação da porcentagem de mineralização, através da medida da produção do dióxido de carbono e da perda de massa. O acompanhamento das alterações na cristalinidade da blenda foi feito um ambos os testes através de Calorimetria Exploratória Diferencial (DSC). Foi verificado que a blenda atingiu 70% de mineralização após 90 dias de incubação no solo. De acordo com a norma ASTM D 6400, esse valor permite concluir que a blenda é biodegradável. Por sua vez, a perda de massa da blenda incubada no solo foi maior do que no meio liquido, mostrando que a biodegradação no solo é bastante eficiente / Abstract: Increasing environmental concens and the waste management policies in the last decade have prompted the use of natural-based biodegradable materials instead od nonbiodegradable petrochemical - basead plastic. The present work it investigated the biodegradation in soil of a PCL/Starch-adipate blend, a natural ¿ based material, according to the ASTM D5988-96 standart and Anderson (1982). Furthermore, it was investigated the biodegradation of this material in liquid medium, according to the ASTM 6691-01 standart and Megaert et al (2000). During the soil tests,the biodegradation was indicated by 'CO IND. 2¿ evolution and mass loss measurements. In the liquid medium, the biodegradation was indicated by mass loss measurements only. Differential Scanning Calorimetry (DSC) was used to follow the crystallinity change in samples treated in liquid and solid medium. It wa observed that the blend reached 70% of mineralization after 90 days of soil incubation. According to the ASTM D 6400, this is a strong indication that the blend is biodegradable. The mass loss of blend sample incubated in soil was higher than for the sample incubated in liquid, showing that the biodegradation in soil was very efficient / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química

Page generated in 0.0743 seconds