• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 9
  • 9
  • 9
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da influência do hipoclorito de sódio na qualidade da superfície e resistência à corrosão de limas de NiTi de diferentes procedências / Evaluation of the influence of sodium hypochlorite in the quality of the surface and resistance to corrosion of NiTi files from different brands

Franco, Emanuela de Carvalho 07 October 2013 (has links)
O presente estudo avaliou a influência do hipoclorito de sódio a 1% e 2,5% na qualidade do acabamento superficial e na resistência à corrosão de duas limas endodônticas: Race® e Hyflex® através de ensaio eletroquímico de polarização potenciodinâmica cíclica (EPPC) e imagens obtidas por microscopia eletrônica de varredura (MEV). Para o EPPC foram utilizados vinte limas de cada marca comercial (#25, conicidade 0.04 e 25 mm de comprimento). Dez dos vinte instrumentos foram individualmente fixados pelo cabo a uma ponta de fio de cobre 0,12 mm de 20 cm de comprimento e posicionado no interior de uma célula eletroquímica com 500 mL de solução de hipoclorito de sódio (NaClO) 1% (Fórmula&Ação) à temperatura ambiente controlada em 23 ºC (±2) até cobrir a parte ativa do instrumento. Os registros foram feitos com o potenciostato da PAR modelo 273A. O ensaio foi repetido nos mesmos padrões para as outras dez limas da mesma marca comercial com o NaClO 2,5%. Além do EPPC, as limas foram submetidas a exames e análises em MEV antes e depois do teste de corrosão para a obtenção de fotomicrografias dos 3 (três) mm finais de cada lima com o intuito de estabelecer parâmetros para a avaliação final. Das fotomicrografias obtidas, 72 foram escolhidas, inseridas no Power Point sem legenda original de identificação, numeradas aleatoriamente para avaliação e projetadas num monitor para 06 avaliadores orientados e calibrados. Os dados obtidos foram tabulados e submetidos aos testes estatísticos pertinentes (Friedman, Wilcoxon e Mann-Whitney). A lima Hyflex® apresentou uma quantidade maior de alterações superficiais (ranhuras, manchas e materiais depositados) antes e depois do ensaio sendo mais suscetível à corrosão. Race® apresentou uma superfície mais polida e regular. Em relação a concentração do NaClO, percebeu-se que os defeitos presentes se tornavam mais evidentes para a concentração maior (2,5%). Nas duas concentrações os itens que apresentaram diferença significativa foram bordas, ranhuras, microcavidades, rebarbas e material depositado. Concluiuse que o acabamento superficial e a concentração da solução de NaClO influenciam a resistência à corrosão dos instrumentos de NiTi. A lima Race® apresentou menor corrosão e melhor acabamento de superfície do que a lima Hyflex® nas condições experimentais testadas. / The present paper evaluated the influence of 1% and 2.5% sodium hypochlorite in the quality of the surface finishing and resistance to corrosion of two endodontic files: Race® and Hyflex® by electrochemical test of cyclic power dynamics polarization (EPPC) and images obtained by scanning electronic microscopy (SEM). Twenty files of each commercial brand (#25, 0.04 taper and 25 mm length) were used in EPPC. Ten from the twenty instruments were individually fixed by the handle to a copper wire tip (0.12 mm diameter and 20 cm length) and placed in the interior of an electrochemical cell with 500 mL sodium hypochlorite solution (NaCIO) 1% (Fórmula e Ação) at the environment temperature controlled in 23ºC (±2) until covering the active part of the instrument. Recordings were made with a PAR potentiostat model 273A. The test was repeated in the same pattern to the other ten files from the same commercial brand with NaClO 2.5%. Besides EPPC, the files were submitted to the scanning electronic microscopy (SEM) test before and after the corrosion test to obtain photomicrographs of the final 3 mm of each file in order to establish the parameters for final evaluation. From the obtained photomicrographs, 72 were chosen and inserted in the Power Point without the original identification legend, randomly numbered for evaluation and projected on the screen to the 06 guided and calibrated evaluators. Data obtained were tabbed and submitted to the relevant statistical tests (Friedman, Wilcoxon and Mann-Whitney). The Hyflex® file showed a higher amount of surface alterations (grooves, stains and deposited materials) before and after the test, being more susceptible to corrosion. Race® showed a more polished and regular surface. As to the NaClO concentration, it was seen that the present defects became more evident in the higher concentration (2.5%). In the two concentrations, the items that presented significant differences were edges, grooves, micro cavities, margins and deposited materials. Conclusion was that surface finishing and the concentration of the NaClO solution influenced the resistance to corrosion of NiTi instruments. The Race® file showed the least corrosion and the best surface finishing compared to the Hyflex® file under the tested experimental conditions.
2

Dynamic properties of nickel-titanium instruments

Sattapan, Boonrat January 1997 (has links)
Root canal preparation in narrow, curved canals is a challenge even for experienced endodontists. Recently nickel-titanium (NiTi) hand files have played an important role in root canal preparation, particularly in curved root canals. Nickel-titanium endodontic instruments were first investigated in 1988 by Walia et al. who found that NiTi files have two to three times more elastic flexibility in bending and torsion, as well as superior resistance to torsional fracture compared with similar stainless steel files.
3

Dynamic properties of nickel-titanium instruments

Sattapan, Boonrat January 1997 (has links)
Root canal preparation in narrow, curved canals is a challenge even for experienced endodontists. Recently nickel-titanium (NiTi) hand files have played an important role in root canal preparation, particularly in curved root canals. Nickel-titanium endodontic instruments were first investigated in 1988 by Walia et al. who found that NiTi files have two to three times more elastic flexibility in bending and torsion, as well as superior resistance to torsional fracture compared with similar stainless steel files.
4

Avaliação da influência do hipoclorito de sódio na qualidade da superfície e resistência à corrosão de limas de NiTi de diferentes procedências / Evaluation of the influence of sodium hypochlorite in the quality of the surface and resistance to corrosion of NiTi files from different brands

Emanuela de Carvalho Franco 07 October 2013 (has links)
O presente estudo avaliou a influência do hipoclorito de sódio a 1% e 2,5% na qualidade do acabamento superficial e na resistência à corrosão de duas limas endodônticas: Race® e Hyflex® através de ensaio eletroquímico de polarização potenciodinâmica cíclica (EPPC) e imagens obtidas por microscopia eletrônica de varredura (MEV). Para o EPPC foram utilizados vinte limas de cada marca comercial (#25, conicidade 0.04 e 25 mm de comprimento). Dez dos vinte instrumentos foram individualmente fixados pelo cabo a uma ponta de fio de cobre 0,12 mm de 20 cm de comprimento e posicionado no interior de uma célula eletroquímica com 500 mL de solução de hipoclorito de sódio (NaClO) 1% (Fórmula&Ação) à temperatura ambiente controlada em 23 ºC (±2) até cobrir a parte ativa do instrumento. Os registros foram feitos com o potenciostato da PAR modelo 273A. O ensaio foi repetido nos mesmos padrões para as outras dez limas da mesma marca comercial com o NaClO 2,5%. Além do EPPC, as limas foram submetidas a exames e análises em MEV antes e depois do teste de corrosão para a obtenção de fotomicrografias dos 3 (três) mm finais de cada lima com o intuito de estabelecer parâmetros para a avaliação final. Das fotomicrografias obtidas, 72 foram escolhidas, inseridas no Power Point sem legenda original de identificação, numeradas aleatoriamente para avaliação e projetadas num monitor para 06 avaliadores orientados e calibrados. Os dados obtidos foram tabulados e submetidos aos testes estatísticos pertinentes (Friedman, Wilcoxon e Mann-Whitney). A lima Hyflex® apresentou uma quantidade maior de alterações superficiais (ranhuras, manchas e materiais depositados) antes e depois do ensaio sendo mais suscetível à corrosão. Race® apresentou uma superfície mais polida e regular. Em relação a concentração do NaClO, percebeu-se que os defeitos presentes se tornavam mais evidentes para a concentração maior (2,5%). Nas duas concentrações os itens que apresentaram diferença significativa foram bordas, ranhuras, microcavidades, rebarbas e material depositado. Concluiuse que o acabamento superficial e a concentração da solução de NaClO influenciam a resistência à corrosão dos instrumentos de NiTi. A lima Race® apresentou menor corrosão e melhor acabamento de superfície do que a lima Hyflex® nas condições experimentais testadas. / The present paper evaluated the influence of 1% and 2.5% sodium hypochlorite in the quality of the surface finishing and resistance to corrosion of two endodontic files: Race® and Hyflex® by electrochemical test of cyclic power dynamics polarization (EPPC) and images obtained by scanning electronic microscopy (SEM). Twenty files of each commercial brand (#25, 0.04 taper and 25 mm length) were used in EPPC. Ten from the twenty instruments were individually fixed by the handle to a copper wire tip (0.12 mm diameter and 20 cm length) and placed in the interior of an electrochemical cell with 500 mL sodium hypochlorite solution (NaCIO) 1% (Fórmula e Ação) at the environment temperature controlled in 23ºC (±2) until covering the active part of the instrument. Recordings were made with a PAR potentiostat model 273A. The test was repeated in the same pattern to the other ten files from the same commercial brand with NaClO 2.5%. Besides EPPC, the files were submitted to the scanning electronic microscopy (SEM) test before and after the corrosion test to obtain photomicrographs of the final 3 mm of each file in order to establish the parameters for final evaluation. From the obtained photomicrographs, 72 were chosen and inserted in the Power Point without the original identification legend, randomly numbered for evaluation and projected on the screen to the 06 guided and calibrated evaluators. Data obtained were tabbed and submitted to the relevant statistical tests (Friedman, Wilcoxon and Mann-Whitney). The Hyflex® file showed a higher amount of surface alterations (grooves, stains and deposited materials) before and after the test, being more susceptible to corrosion. Race® showed a more polished and regular surface. As to the NaClO concentration, it was seen that the present defects became more evident in the higher concentration (2.5%). In the two concentrations, the items that presented significant differences were edges, grooves, micro cavities, margins and deposited materials. Conclusion was that surface finishing and the concentration of the NaClO solution influenced the resistance to corrosion of NiTi instruments. The Race® file showed the least corrosion and the best surface finishing compared to the Hyflex® file under the tested experimental conditions.
5

Determinação da área alargada posterior ao retratamento do canal radicular com instrumentos de níquel-titânio / Determination of the enlarged area after retreatment of the root canal with nickel-titanium instruments.

Pereira, Larissa Ernesto 27 July 2018 (has links)
O objetivo do presente estudo foi determinar a área alargada posterior ao retratamento do canal radicular com instrumentos de níquel-titânio em imagens de tomografia computadorizada de feixe cônico. Sessenta raízes mesiais de molares inferiores foram selecionadas e submetidas a tomografia computadorizada de feixe cônico(TCFC) em 4 períodos de: antes do preparo (T1), após o preparo (T2), após o retratamento (T3) e após a complementação do retratamento (T4). Após a TCFC inicial (T1), os dentes foram submetidos ao protocolo de abertura coronária e exploração dos canais com lima manual tipo K n.15, preparados com instrumentos ProTaper Next (até X3: # 30.07), e submetidos novamente a TCFC (T2); A seguir foram obturados pela técnica híbrida de Tagger com cimento AH Plus, e submetidos a 1000 ciclos de termociclagem simulando um período de 12 meses. Subsequentemente, os espécimes foram distribuídos de acordo com os protocolos de desobturação do canal radicular, em três grupos (n=10): G1- Protaper Universal Retratamento (D1: #30.09; D2: #25.08; D3: #20.07;); G2- Mtwo Retratamento (#25.05) e G3- DRaCe (DR1: #30.10; DR2: #25.04). Após a desobturação, os espécimes foram submetidos novamente à TCFC (T3). Em seguida, foram submetidos ao protocolo de complementação para remoção do material obturador, em três grupos (n=10): G1, G2 e G3: PT next X4: #40.06. A seguir os espécimes foram submetidos novamente à TCFC (T4) para avaliação da área alargada do canal radicular. A média e o desvio padrão das variáveis quantitativas foram obtidas. A normalidade dos dados foi avaliada pelo teste de Kolmogorov-Smirnov. As variáveis foram avaliadas pelo Teste-t para amostras pareadas para avaliar a diferença entre a área desgastada entre o preparo (Tomografia 2) e o retratamento (Tomografia 4). As variáveis foram avaliadas pelo Teste de Análise de Variância (ANOVA) post hoc Tukey para a comparação entre Protaper-R (grupo 1), Mtwo-R (grupo 2) e D- Race (grupo 3). Foram considerados significativos valores de p < 0,05. A análise de variância evidenciou diferença estatisticamente significante em relação aos grupos em canal mesiovestibular em nível 2 mm abaixo de furca p<0,038 e em canal mesiovestibular em nível 4 mm abaixo de furca p<0,005. Evidenciou também diferença estatisticamente significante em relação aos grupos 1, 2 e 3 em canal mesiovestibular em nível 2 mm abaixo de furca após o retratamento p<0,028. A diferença média da área alargada entre o preparo e o retratamento em canais mesiovestibulares comparando os grupos Protaper-R, Mtwo-R e D-race evidenciou diferença estatisticamente significante em todos os grupos (p<0,000 e p<0,029) e em canais mesiolinguais valores entre p<0,000 e p<0,029. Conclui-se que as técnicas de complementação avaliadas aumentaram a área do canal radicular, contribuindo para a remoção do remanescente de material obturador, sendo que o sistema Protaper-R ® permitiu maior desgaste. Embora tenha havido ampliação da área do canal radicular em níveis determinados, nenhuma das técnicas avaliadas foram capazes de remover completamente o material obturador dos canais radiculares / The objective of the present study was to determine the enlarged area after retreatment of the root canal with nickel-titanium instruments in conical beam computed tomography images. Sixty mesial roots of mandibular molars were selected and submitted to concomitant computed tomography (CBCT) in 4 periods of: before preparation (T1), after preparation (T2), after retreatment (T3) and after completing retreatment (T4). After the initial CBCT (T1), the teeth were submitted to the protocol of coronary opening and exploration of channels with manual file type K n.15, prepared with ProTaper Next instruments (up to X3: # 30.07), and again submitted to CBCT); They were then filled by the Tagger hybrid technique with AH Plus cement and submitted to 1000 cycles of thermocycling simulating a period of 12 months. Subsequently, the specimens were distributed according to root canal clearance protocols, in three groups (n = 10): G1 Protaper Universal Retreatment (D1: # 30.09; D2: # 25.08; D3: # 20.07;); G2- Mtwo Retreatment (# 25.05) and G3- DRaCe (DR1: # 30.10; DR2: # 25.04). After disintegration, the specimens were again submitted to TCFC (T3). Afterwards, they were submitted to the complementation protocol to remove the obturator material, in three groups (n = 10): G1, G2 and G3: PT next X4: # 40.06. Afterwards the specimens were again submitted to TCFC (T4) for evaluation of the enlarged area of the root canal. The mean and standard deviation of the quantitative variables were obtained. The normality of the data was evaluated by the Kolmogorov-Smirnov test. The variables were evaluated by the t-Test for paired samples to evaluate the difference between the worn area between the preparation (Tomography 2) and the retreatment (Tomography 4). The variables were evaluated by the Tukey post-hoc ANOVA for the comparison between Protaper- R (group 1), Mtwo-R (group 2) and D-Race (group 3). Values of p <0.05 were considered significant. The analysis of variance showed a statistically significant difference in relation to the groups in mesiobuccal channel at level 2 mm below furca p <0.038 and in mesiobuccal channel at level 4 mm below furca p <0.005. There was also a statistically significant difference in relation to groups 1, 2 and 3 in mesiobuccal channel at level 2 mm below furcation after retreatment p <0.028. The mean difference in the wide area between preparation and retreatment in mesiobuccal canals comparing the Protaper-R, Mtwo-R and D-race groups showed a statistically significant difference in all groups (p <0.000 and p <0.029) and in mesiolinguistic channels values between p <0.000 and p <0.029. It was concluded that the complementation techniques evaluated increased the root canal area, contributing to the removal of the remainder of the obturator material, and the Protaper-R ® system allowed for greater wear. Although there was enlargement of the root canal area at determined levels, none of the techniques evaluated were able to completely remove the obturator material from the root canals
6

Análise multidimensional do preparo de canais radiculares curvos com instrumentos de níquel-titânio em rotação contínua e reciprocante / Multidimensional analysis of curved root canal preparation using continuous or reciprocating nickel-titanium instruments

Mamede Neto, Iussif 18 November 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-01-04T09:35:23Z No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-04T09:59:04Z (GMT) No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-04T09:59:04Z (GMT). No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-11-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Material and methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divide into 6 groups (n=16) according to the rotary file used: Group 1- ProTaper Next®; Group 2- ProTaper Gold®; Group 3- Mtwo®; Group 4- BioRaCe®; Group 5- WaveOne Gold®; Group 6- Reciproc®. Root canals were prepared according to manufacturer’s instructions. Cone-beam computed tomography scans were obtained before and after canal preparation. Measurements were made at five different points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation. Transportation and centering ability were analyzed following the recommendations made by Gambill et al. (1996). Results: The greatest mesiodistal (MD) transportation (T) was found for Reciproc® files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc®, ProTaper Gold® and ProTaper Next® files (p<0.05). The greatest mesiodistal (MD) centering ability (CA) was found for BioRaCe® files (p<0.05), and the greatest buccolingual (BL) CA, for BioRaCe® and Mtwo® files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc® files had the greatest MD T and BL T. BioRaCe® files had the greatest MD CA, whereas BL CA was similar for BioRaCe® and Mtwo® files. / Objetivo: Avaliar o índice de transporte (IT) e a capacidade de centralização (CC) do preparo do canal radicular com instrumentos endodônticos de níquel-titânio acionados em rotação contínua e reciprocante. Materiais e métodos: Noventa e seis canais mesiovestibulares de molares inferiores (primeiro e segundo) foram aleatoriamente divididos em 06 grupos (n=16), de acordo com o instrumento rotatório utilizado: Grupo 1- ProTaper Next®; Grupo 2- ProTaper Gold®; Grupo 3- Mtwo®; Grupo 4- BioRaCe®; Grupo 5- WaveOne Gold®; Grupo 6- Reciproc®. A técnica de preparo do canal radicular obedeceu a orientação dos fabricantes. Tomografia computadorizada de feixe cônico foi realizada antes e após o preparo dos canais radiculares. Foram estabelecidos 06 níveis para a realização das mensurações nas imagens: 2, 3 e 4 mm aquém do vértice radicular e 2, 3 e 4 mm abaixo da furca. O índice de transporte e a capacidade de centralização foram analizados conforme proposto por Gambill et al. (1996). Resultados: O maior IT no sentido mesiodistal (MD) foi observado com o Reciproc® (p<0,05), enquanto que no sentido vestíbulolingual (VL) foram verificados com Reciproc®, ProTaper Gold® e ProTaper Next® (p<0,05). Os maiores valores de CC(MD) e (VL) foram observados com os sistemas BioRaCe® (p<0,05) e BioRaCe® e Mtwo® (p<0,05), respectivamente. Conclusão: Todos os sistemas promoveram transporte do canal radicular. Nenhum instrumento mostrou capacidade de centralização do preparo perfeita. O Reciproc® obteve os valores maiores de IT(MD) e (VL). O sistema BioRaCe® apresentou a maior CC(MD), enquanto que no sentido (VL) o BioRaCe® e Mtwo® mostraram capacidades similares.
7

Avaliação microtomográfica de canais mesiais de molares inferiores preparados com sistemas rotatórios e reciprocantes / Computed microtomography analysis of mesial canals of mandibular molars prepared with rotary and reciprocating systems

Marília Fagury Videira Marceliano Alves 12 September 2013 (has links)
O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (CT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em TC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (&#945;=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 76,75; 42,22 19,22; e 14,68 17,69, respectivamente); WaveOne (105,09 64,82; 29,54 19,21; 14,81 9,10, respectivamente); Twisted File (111,83 43,09; 33,31 18,40; 9,16 6,57, respectivamente), e HyFlex (151,74 149,37; 43,08 41,44; 10,80 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 13,1), seguido por Reciproc (81,3 16,9), Twisted File (78,3 14,4) e, por fim, WaveOne (76,9 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular. / The aim of this work was to analyze, in X-ray computed microtomography (CT), the root canal preparation of mandibular molars with different engine driven systems. 58 mesial roots were selected, of anatomic diameter corresponding to #10. For the analysis in TC, a stainless steel ring was manufactured in the same shape as the brace for CT sampling, in order to serve as a mold to insert the roots in Duralay resin, so as to standardize the position of the specimen in the initial and final scanning. The canals were prepared with the Reciproc R25 (n=16), WaveOne Primary File (n=16), Twisted File (n=14) and HyFlex (n=12) systems. After being scanned, they were three-dimensionally reconstructed and quantitatively evaluated as regards the variation of volume (mm3), surface area (mm2) and structure model index (SMI). In addition, the qualitative evaluation of the cross sections by third and by quadrant (MV, ML, DV, DL) was carried out, along with the wall touching evaluation. The parametric data were statistically analyzed by ANOVA and t-tests for paired samples (&#945;=5%). No statistical difference was observed in the qualitative parameters evaluated for Reciproc (142.77 76.75; 42.22 19.22; and 14.68 17.69; respectively), WaveOne (105.09 64.82; 29.54 19.21; 14.81 9.10; respectively), Twisted File (111.83 43.09; 33.31 18.40; 9.16 6.57; respectively) and HyFlex (151.74 149.37; 43.08 41.44; 10.80 8.52) (p=0,423). Significant difference was observed within each group between the pre- and post-results. The Kruskal-Wallis non-parametric test was applied for the evaluation as regards root canal wall touching. At the end, we observed that the HyFlex system presented the highest touching rate (82.3 13.1), followed by the Reciproc (81.3 16.9), Twisted File (78.3 14.4) and, finally, WaveOne (76.9 21.7) systems (p>0.05). As for the thirds, was not observed any significant difference (p=0.424). The results of the evaluation in the intergroup quadrants did not show any difference; however, they showed that there was a preparation trend towards the distal wall in the cervical third. At the end, it can conclude that the systems tested are equivalent as regards the preparation of mesial canals of mandibular molars, but none of the techniques was capable of fully touching all root canal walls.
8

Avaliação microtomográfica de canais mesiais de molares inferiores preparados com sistemas rotatórios e reciprocantes / Computed microtomography analysis of mesial canals of mandibular molars prepared with rotary and reciprocating systems

Marília Fagury Videira Marceliano Alves 12 September 2013 (has links)
O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (CT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em TC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (&#945;=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 76,75; 42,22 19,22; e 14,68 17,69, respectivamente); WaveOne (105,09 64,82; 29,54 19,21; 14,81 9,10, respectivamente); Twisted File (111,83 43,09; 33,31 18,40; 9,16 6,57, respectivamente), e HyFlex (151,74 149,37; 43,08 41,44; 10,80 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 13,1), seguido por Reciproc (81,3 16,9), Twisted File (78,3 14,4) e, por fim, WaveOne (76,9 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular. / The aim of this work was to analyze, in X-ray computed microtomography (CT), the root canal preparation of mandibular molars with different engine driven systems. 58 mesial roots were selected, of anatomic diameter corresponding to #10. For the analysis in TC, a stainless steel ring was manufactured in the same shape as the brace for CT sampling, in order to serve as a mold to insert the roots in Duralay resin, so as to standardize the position of the specimen in the initial and final scanning. The canals were prepared with the Reciproc R25 (n=16), WaveOne Primary File (n=16), Twisted File (n=14) and HyFlex (n=12) systems. After being scanned, they were three-dimensionally reconstructed and quantitatively evaluated as regards the variation of volume (mm3), surface area (mm2) and structure model index (SMI). In addition, the qualitative evaluation of the cross sections by third and by quadrant (MV, ML, DV, DL) was carried out, along with the wall touching evaluation. The parametric data were statistically analyzed by ANOVA and t-tests for paired samples (&#945;=5%). No statistical difference was observed in the qualitative parameters evaluated for Reciproc (142.77 76.75; 42.22 19.22; and 14.68 17.69; respectively), WaveOne (105.09 64.82; 29.54 19.21; 14.81 9.10; respectively), Twisted File (111.83 43.09; 33.31 18.40; 9.16 6.57; respectively) and HyFlex (151.74 149.37; 43.08 41.44; 10.80 8.52) (p=0,423). Significant difference was observed within each group between the pre- and post-results. The Kruskal-Wallis non-parametric test was applied for the evaluation as regards root canal wall touching. At the end, we observed that the HyFlex system presented the highest touching rate (82.3 13.1), followed by the Reciproc (81.3 16.9), Twisted File (78.3 14.4) and, finally, WaveOne (76.9 21.7) systems (p>0.05). As for the thirds, was not observed any significant difference (p=0.424). The results of the evaluation in the intergroup quadrants did not show any difference; however, they showed that there was a preparation trend towards the distal wall in the cervical third. At the end, it can conclude that the systems tested are equivalent as regards the preparation of mesial canals of mandibular molars, but none of the techniques was capable of fully touching all root canal walls.
9

Caracterização das dimensões da aresta lateral de corte e do núcleo dos instrumentos Mtwo®, ProTaper®, Wizard Navigator® e BioRace® / Characterization of flute and shank dimensions of Mtwo®, ProTaper®, Wizard Navigator® and BioRace® instruments

Brito, Ana Paula Pedroso 10 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-11T11:47:52Z No. of bitstreams: 2 Dissertação - Ana Paula Pedroso Brito - 2015.pdf: 1014799 bytes, checksum: e2dcf8a46ffc5134b0215684a6190af3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-11T11:50:48Z (GMT) No. of bitstreams: 2 Dissertação - Ana Paula Pedroso Brito - 2015.pdf: 1014799 bytes, checksum: e2dcf8a46ffc5134b0215684a6190af3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-11T11:50:48Z (GMT). No. of bitstreams: 2 Dissertação - Ana Paula Pedroso Brito - 2015.pdf: 1014799 bytes, checksum: e2dcf8a46ffc5134b0215684a6190af3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-03-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Purpose: to determine flute-to-shank ratio of rotatory nickel-titanium instruments Mtwo® #30/.05, ProTaper® #30/.09, Wizard Navigator® #30/.06 and BioRace® 35/.04. Material and methods: Instruments’ diameter were measured with a digital caliper in the first five flutes and abraded longitudinally by a diamond disk until instrument half diameter was achieved in flutes region. The samples were then fixed in stubs and SEM images were performed at 60X magnification. The flutes and shanks areas were measured, and flute-toshank ratio was achieved using software AxioVision®. Statistical analysis was performed by ANOVA and Tukey’s Test for comparison between groups. Results: There was significant statistical difference for flutes areas. Mtwo® #30/.05 had the higher shank areas and was significantly different from the other instruments, except for Wizard Navigator #30/.06 ate the second flute site. Flute-to-shank ratio showed a 3-28% variation. Conclusions: Flutes dimensions were lower than shanks’. Wizard Navigator® #30/.05 had lower flute-to-shank ratio than other files. / Objetivo: Relacionar a aresta lateral de corte e o núcleo de instrumentos endodônticos de níquel-titânio de rotação contínua Mtwo® #30/.05, ProTaper® #30/.09, Wizard Navigator® #30/.06 e BioRace® 35/.04. Material e métodos: Os instrumentos foram medidos com paquímetro digital para aferição do seu diâmetro nas cinco primeiras arestas de corte e desgastados longitudinalmente com disco diamantado flexível dupla face até atingir metade do diâmetro do instrumento nas regiões das arestas laterais de corte. A seguir, as amostras foram fixadas em stubs e obtidas as imagens por microscopia eletrônica de varredura com aumento de 60X. Foram realizadas mensurações das áreas da aresta lateral de corte e do núcleo, e a razão entre estas medidas utilizando o software AxioVision®. A análise estatística foi realizada por meio da ANOVA e do Teste de Tukey para comparação entre os grupos. Resultados: Houve diferença significativa entre as áreas das arestas para todos os instrumentos. O instrumento Mtwo® #30/.05 apresentou as maiores áreas do núcleo, com diferença significativa para todos os demais instrumentos, à exceção do Wizard Navigator® #30/.06 na região da segunda aresta. A relação entre a área da aresta de corte e do respectivo núcleo mostrou que a aresta representou áreas que variaram de 3% a 28% do núcleo. Conclusões: As dimensões da aresta lateral de corte foram inferiores às do núcleo em todos os instrumentos. O Wizard Navigator® #30/.06 apresentou uma relação entre as dimensões da aresta em relação ao núcleo inferiores aos demais

Page generated in 0.0879 seconds