• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 9
  • 9
  • 9
  • 9
  • 8
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 60
  • 60
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da infiltração marginal em restaurações de resinas compostas para dentes posteriores: efeito de material, preparo cavitário e condicionamento do esmalte a nível cervical

Araújo, Rosehelene Marotta [UNESP] January 1989 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1989Bitstream added on 2015-01-26T13:30:20Z : No. of bitstreams: 1 000022956.pdf: 2284097 bytes, checksum: a572b308f0f545c71d9428488580a36f (MD5) / Por muitos anos a profissão odontológica tem procurado um material estético para substituir as ligas de amálgama. Recentemente, têm aparecido no comércio as resinas compostas para dentes posteriores indicadas para restaurações onde não há incidência de forças mastigatórias. Tais resinas têm, porém, apresentado falhas, e, entre elas, a infiltração marginal, que tem enorme importância, pois é responsável pela sensibilidade pós-operatória, manchamento e ocorrência de cáries secundárias com consequentes alterações patológicas da polpa. Este trabalho teve a finalidade de estudar ''in vitro'' a infiltração marginal, a nível cervical, de restaurações classe II com as resinas posteriores quimicamente ativadas P10 e fotoativadas P30, em dois tipos de cavidades: convencional e adesiva. Foi verificado também o efeito do condicionamento ácido nesta região. A pesquisa foi realizada em dentes pré-molares recentemente extraídos por motivo ortodôntico, e para obter cavidades padronizadas os preparos foram feitos com a utilização de um microscópio modificado por GABRIELLI e cols.25 Foi utilizado adesivo dentinário (Scotchbond) em todos grupos experimentais. A infiltração foi evidenciada por meio do corante Rodamina B, após ciclagem térmica entre as temperaturas 10°C e 50°C, e analisada seguindo o critério de HIRSCH e WEINREB37, modificado, com auxílio de uma lupa estereoscópica ZEISS com 10 aumentos. Pelos resultados obtidos, pudemos verificar que: 1- Ocorreu infiltração marginal a nível cervical em 77,5% das restaurações de cavidades convencionais e em 47,5% das cavidades adesivas. 2- A maior percentagem de infiltração, independentemente dos fatores em estudo, ocorreu sempre no nível 3, ou seja, com infiltração até a parede axial. 3- Tanto a resina quimicamente ativada quanto a fotoativada permitiram a mesma infiltração. 4- O condicionamento ... / For many years the dental profession has sought an esthetic material to replace the amalgam alloys. Recently composite resins for posterior teeth have been introduced into the marketplace. The manufacturers claimed that these materials are indicated for stress-bearing restoration. However. such resins have presented some limitations such as marginal leakage which has great clinical importance because it is responsible for postoperative sensitivity, and occurence of secundary caries followed by pathological changes of the pulp. The purpose of this ''in vitro'' study was to investigate the cervical marginal leakage in class II restorations with chemically cured resin - PlO - and light- cured resin - P30 - in two types of cavities: conventional and adhesive. The effect of acid-etching in this area was also observed. The cavities were prepared in premolar teeth, recently extracted for orthodontic purposes, using a Microscope Modified by GABRIELLI and cols.25, in order to obtain standardized cavities. Dentine adhesive (Scotchbond) was used in all experimental groups Leakage was evidenced by Rodamina B dye penetration after thermocycling procedure between 10°C and 50ºC temperature and analysed according to HIRSCH g WEINREB modified criterion by using ZEISS Stereoscopic Magnifying Glass (10x). According to the results, we should concluded that: 1- Cervical marginal leakage occurred to 77,5% of conventional cavities restorations and 47,5% of adhesives cavities. 2- The major percents of leakage, regardless the factors studied, always occurred at level 3, that is, with leakage up to axial wall. 3- Either chemically cured resin or light – cured resin presented the same leakage. 4- The acid-etching reduced from 70% to 55% the leakage percentage observed. 5- The leakage observed for adhesive or conventional cavities continued when chemically cured resin or light- cured resin was used. 6- Acid-etching...
32

Estudo comparativo de resistência ao cisalhamento em reconstruções com amálgama, utilizando como procedimento retentivo pino rosqueável, amalgapin e adesivo dentário /

Naressi, Suely Carvalho Mutti. January 1995 (has links)
Orientador: José Benedicto de Mello / Banca: Dan Mihail Fichman / Banca: Maria Amélia Maximo de Araujo / Resumo: Objetivando evitar perda de dentes posteriores com grandes destruições coronárias, este trabalho comparou, mediante termociclagem e testes laboratoriais, a resistência ao cisalhamento entre três procedimentos retentivos de reconstrução com amálgama em dentes pré-molares com preparo tipo flat: pino rosqueável, amalgapin e amálgama adesivo. Os valores resultantes da ação das forças e a análise das falhas, visualmente e em microscopia ótica estereoscópica, permitiram inferir que o melhor procedimento retentivo ocorreu com pino rosqueável, seguido do amalgapin. A técnica do amálgama adesivo, com o material por nós utilizado, apresentou-se ineficaz como único procedimento retentivo neste tipo de reconstrução / Abstract: In order to avoid the loss of largely destroyed crowns of posterior teeth, this study dealt with laboratory tests to compare the resistance to shear strengths application among three retentive procedures for amalgam buildups: adhesive amalgam, amalgapin and threadned pin. The failures resultant from the strength action, analysed visually and stereoscopic otic microscopy, permitted to conclude that the best retentive procedure happened with threadned pin, followed by amalgapin. The adhesive amalgam restoration technique was considered non-efficient, for the adhesive used, as the only retentive procedure in this kind of buildup / Mestre
33

Influência de diferentes técnicas de instrumentação no travamento e adaptação de cones de guta-percha .O4 analisados por tomografia computadorizada /

Vasconcelos, Rafaela Andrade de. January 2012 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Ana Paula Martins Gomes / Banca: Norberti Bernardineli / Resumo: O objetivo deste estudo foi avaliar a influência de diferentes técnicas de instrumentação no travamento e adaptação do cone de guta-percha .04 em canais radiculares. A avaliação foi realizada observando o local onde o cone entrava em contato com o maior número de paredes internas do canal radicular através da tomografia computadorizada de feixe cônico (TCFC). Foram utilizados 105 dentes humanos unirradiculados, divididos em 7 grupos de instrumentação (n=15): híbrida oscilatório + Manual (OM); Manual (M); Protaper Universal (P); híbrida oscilatório + Protaper (OP); Mtwo (MT); híbrida oscilatório + Mtwo (OMT); Reciproc (R). Finalizadas as instrumentações, o travamento do cone .04 foi realizado 1mm aquém do ápice sendo conferido com uma radiografia digital. As imagens tomográficas foram adquiridas através do TCFC ICat e realizadas nos cortes frontal, sagital e transversal através do software Xoran. Os dados foram submetidos à análise estatística de comparação das proporções via teste "Z" da curva normal, teste Exato de Fisher e quando necessário teste Qui-quadrado. Os resultados apresentaram 100% de travamento do cone no terço apical em todas as instrumentações. A adaptação do cone nas quatro paredes do canal apresentou uma variação de 26,67% (OMT e P) a 73,33% (MT) havendo diferença estatística entre esses grupos (pvalor = 0,027 < 0,05). Em todos os tipos de instrumentação as paredes que apresentaram menor contato foram as vestibulares e as linguais. Os valores médios de área sem contato do cone variaram de 0,06mm2 (MT) a 0,41mm2 (OMT). Concluiu-se que as técnicas de instrumentação podem influenciar no travamento do cone quanto ao número de paredes contactadas ao canal, e também, ao valor de área em que o cone não se adapta ao canal, e não influenciam no nível de travamento do cone / Abstract: The aim of this study was to assess the influence of different instrumentation techniques on the adaptation of .04 gutta-percha points into root canals. The assessment was performed at areas of greater contact of gutta-percha to root canal walls, by means of cone-beam computed tomography. One hundred and five uniradicular human teeth were used. Teeth were divided into 7 groups according to instrumentation (n=15) technique: hybrid oscillatory+Manual (OM); Manual (M); Protaper Universal (P); hybrid oscillatory+Protaper (OP); Mtwo (MT); hybrid oscilatory+Mtwo (OMT); Reciproc (R). Gutta-percha point was adapted 1mm from apex and confirmed by digital radiography. Tomographic images were obtained through CFCT Icat (imaging Science International, USA) and analyzed at the frontal, sagittal and transversal planes by means of Xoran software (Xoran Technologies, USA). Data were submitted to statistical Z test for normal distribution, Exact Fisher test, and Chi-square when necessary. Results: One hundred percent of points were adapted at the apical third of the roots for every instrumentation procedures. The adaptation of points at the four canal walls varied from 26.67% (OMT and P) to 73.33% (MT), with statistical differences among the groups (p = 0,027). The buccal and lingual walls presented the lowest contact of point for all instrumentation procedures. The mean average wall areas without contact varied from 0.06mm2 to 0.41mm2(OMT). It was concluded that different instrumentation techniques might influence the adaptation of gutta-percha points in relation to the number of walls contacted, as well as in relation to the wall area not adapted to the guttapercha point, and no influence in adaptation level / Mestre
34

Influência de diferentes procedimentos restauradores na resistência á fratura de dentes com cavidade classe IV submetidos ao clareamento dental interno /

Roberto, Andiara Ribeiro. January 2012 (has links)
Orientador: José Roberto Cury Saad / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Banca: Marcos Porto de Arruda Filho / Banca: Jacy Ribeiro de Carvalho Junior / Resumo: Este estudo teve o objetivo de investigar a influência de diferentes procedimentos restauradores diretos com resina composta e pinos de fibra de vidro, na resistência à fratura de dentes com cavidades Classe IV, tratados endodonticamente e submetidos ao clareamento interno. Quarenta (n=40) incisivos laterais superiores humanos hígidos foram utilizados. Todos os dentes, com exceção do Grupo controle, foram submetidos ao tratamento endodôntico e então divididos em 5 Grupos (n=8): GI: Dentes hígidos; GII: Dentes tratados endodonticamente + resina composta (RC); GIII: Dentes tratados endodonticamente + clareamento com peróxido de hidrogênio (PH) a 35% + RC; GIV: Dentes tratados endodonticamente + Clareamento com PH a 35% + pino de fibra de vidro (Everstick/StichTeck) + RC; GV: Dentes tratados endodonticamente + Clareamento PH a 35% + RC e pino de fibra de vidro (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA);. Os dentes tratados endodônticamente receberam cortes na coroa simulando uma classe IV e posteriormente restaurações de resina composta. O sistema LED-LASER Whitening Lase Light Plus (DMC Equipamentos Ltda, São Carlos, SP, Brasil) foi utilizado para ativação do agente clareador. Após o processo de clareamento, a restauração provisória e o tampão cervical dos dentes submetidos ao clareamento foram removidos para que cada Grupo fosse submetido ao procedimento restaurador. Após a confecção das restaurações as mesmas foram submetidas ao teste de resistência a fratura, em máquina de ensaios (EMIC). A Análise de Variância apontou efeito significativo de Grupos sobre a resistência (p=0,041). O teste de Tukey foi aplicado nas comparações múltiplas das médias de resistência, identificando somente a média de GIII (dentes tratados endodonticamente +clareamento com PH... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to investigate the influence of restorative procedures on fracture resistance of teeth with Class IV cavities endodontically treated and submitted to internal bleaching with light source acceleration using LED-LASER system. Forty (n = 40) lateral incisors and healthy humans were used. All teeth, except for the control Group, were submitted to endodontic treatment and then divided into 5 Groups (n = 8): GI: healthy teeth, GII: endodontically treated teeth + composite, GIII: Teeth whitening endodontically treated with PH 35% + composite, GIV: Teeth whitening endodontically treated with PH 35% glass fiber post (Everstick / StichTeck) + composite, GV: Teeth whitening endodontically treated PH 35% + composite fiber and glass post (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA). The crow of endodontically treated tooth was cut simulating a Class IV. The system LED LASER-Light Plus Whitening Lase (DMC Equipment Ltda, São Carlos, SP, Brazil) was used to activate the bleaching agent. After the whitening process, the buffer cervical and the temporary restoration of teeth submitted to bleaching have been removed so that each Group was subjected to the restorative procedure. After restorations the specimens were subjected to the same fracture toughness test, in a testing machine (EMIC). Analysis of Variance (ANOVA) showed significant effect on the resistance Group (p = 0.041). The Tukey test was applied in multiple comparisons for resistance means values, identifying only the mean of GIII (endodontically treated teeth bleaching with PH 35% + composite) significantly lower than GI (healthy teeth) (p = .026). It was concluded that teeth endodonticamentes treated with cavity class IV, subjected to internal dental bleaching with PH 35% and only restored with RC, have lower fracture toughness when compared to... (Complete abstract click electronic access below) / Doutor
35

Influência de diferentes técnicas de instrumentação no travamento e adaptação de cones de guta-percha .O4 analisados por tomografia computadorizada

Vasconcelos, Rafaela Andrade de [UNESP] 06 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-06Bitstream added on 2014-06-13T20:40:08Z : No. of bitstreams: 1 vasconcelos_ra_me_sjc.pdf: 479818 bytes, checksum: 9f3f754b2f47e390a6321179a6a8e7da (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência de diferentes técnicas de instrumentação no travamento e adaptação do cone de guta-percha .04 em canais radiculares. A avaliação foi realizada observando o local onde o cone entrava em contato com o maior número de paredes internas do canal radicular através da tomografia computadorizada de feixe cônico (TCFC). Foram utilizados 105 dentes humanos unirradiculados, divididos em 7 grupos de instrumentação (n=15): híbrida oscilatório + Manual (OM); Manual (M); Protaper Universal (P); híbrida oscilatório + Protaper (OP); Mtwo (MT); híbrida oscilatório + Mtwo (OMT); Reciproc (R). Finalizadas as instrumentações, o travamento do cone .04 foi realizado 1mm aquém do ápice sendo conferido com uma radiografia digital. As imagens tomográficas foram adquiridas através do TCFC ICat e realizadas nos cortes frontal, sagital e transversal através do software Xoran. Os dados foram submetidos à análise estatística de comparação das proporções via teste “Z” da curva normal, teste Exato de Fisher e quando necessário teste Qui-quadrado. Os resultados apresentaram 100% de travamento do cone no terço apical em todas as instrumentações. A adaptação do cone nas quatro paredes do canal apresentou uma variação de 26,67% (OMT e P) a 73,33% (MT) havendo diferença estatística entre esses grupos (pvalor = 0,027 < 0,05). Em todos os tipos de instrumentação as paredes que apresentaram menor contato foram as vestibulares e as linguais. Os valores médios de área sem contato do cone variaram de 0,06mm2 (MT) a 0,41mm2 (OMT). Concluiu-se que as técnicas de instrumentação podem influenciar no travamento do cone quanto ao número de paredes contactadas ao canal, e também, ao valor de área em que o cone não se adapta ao canal, e não influenciam no nível de travamento do cone / The aim of this study was to assess the influence of different instrumentation techniques on the adaptation of .04 gutta-percha points into root canals. The assessment was performed at areas of greater contact of gutta-percha to root canal walls, by means of cone-beam computed tomography. One hundred and five uniradicular human teeth were used. Teeth were divided into 7 groups according to instrumentation (n=15) technique: hybrid oscillatory+Manual (OM); Manual (M); Protaper Universal (P); hybrid oscillatory+Protaper (OP); Mtwo (MT); hybrid oscilatory+Mtwo (OMT); Reciproc (R). Gutta-percha point was adapted 1mm from apex and confirmed by digital radiography. Tomographic images were obtained through CFCT Icat (imaging Science International, USA) and analyzed at the frontal, sagittal and transversal planes by means of Xoran software (Xoran Technologies, USA). Data were submitted to statistical Z test for normal distribution, Exact Fisher test, and Chi-square when necessary. Results: One hundred percent of points were adapted at the apical third of the roots for every instrumentation procedures. The adaptation of points at the four canal walls varied from 26.67% (OMT and P) to 73.33% (MT), with statistical differences among the groups (p = 0,027). The buccal and lingual walls presented the lowest contact of point for all instrumentation procedures. The mean average wall areas without contact varied from 0.06mm2 to 0.41mm2(OMT). It was concluded that different instrumentation techniques might influence the adaptation of gutta-percha points in relation to the number of walls contacted, as well as in relation to the wall area not adapted to the guttapercha point, and no influence in adaptation level
36

Avaliação histologica da reação do tecido subcutaneo de ratos apos a implantação de cimentos endodonticos

Gomes Filho, João Eduardo 23 April 2001 (has links)
Orientador : Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T04:53:03Z (GMT). No. of bitstreams: 1 GomesFilho_JoaoEduardo_D.pdf: 3941547 bytes, checksum: 7475d7da57af1099a7407a3a7e94295f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar in vivo a biocompatibilidade dos cimentos endodônticos Endométhasone, Pulp Canal Sealer e AH-Plus, após a implantação em tecido subcutâneo de ratos. Vinte e quatro ratos Wistar-Furth foram utilizados. Cada cimento foi colocado no interior de tubos de polietileno e implantados em locais específicos no subcutâneo do dorso do animal. Os blocos de tecido foram removidos após 3, 7 e 30 dias, fixados e processados pelo método de inclusão em glicol metacrilato para avaliação microscópica. Observou-se no terceiro dia, uma resposta inflamatória mais intensa, com células do infiltrado agudo para todos os cimentos, sendo que o cimento Pulp Canal Sealer apresentou uma reação mais branda. No sétimo dia, o tecido já se apresentava mais organizado principalmente para o cimento AH-Plus, o qual permitiu o início de formação de cápsula fibrosa na embocadura do tubo. No trigésimo dia, todos os cimentos apresentaram formação de cápsula fibrosa, com poucas células inflamatórias crônicas. Neste período mais longo, o cimento Pulp Canal Sealer apresentou um estágio mais avançado de organização tecidual, enquanto os cimentos AH-Plus e Endométhasone não diferiram muito entre si, mostrando ainda um leve grau de inflamação / Abstract: The aim of this study was to evaluate the in vivo biocompatibility of Endométhasone, Pulp Canal Sealer e AH-Plus root canal sealers, after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Each sealer was placed in polyethylene tubes and implanted into specific dorsal subdermal tissues sites. Implants were removed afier 3, 7 and 30 days, fixed and processed by glycol methacrylate method to be microscopically examined. On the third day, it was possible to observe a severe reaction with acute inflammatory cells with ali sealers, but a milder reaction was identified with Pulp Canal Sealer. The organization of the tissue was clearer, specially with AH-Plus, with reduction of the severity of the reaction on the ih day. The connective tissue with a few inflammatory cells was present with ali sealers on the 30th day. In this longer time, with Pulp Canal Sealer was the sealer, the tissue was more organized, while Endométhasoe and AH-Plus did not differ each other and they showed a milder persistent reaction / Doutorado / Endodontia / Doutor em Odontologia
37

Resistencia a fratura de dentes desvitalizados restaurados atraves de resina composta com ou sem pino intra-radicular

Carlini Junior, Bruno 28 June 1999 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:49:09Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_M.pdf: 4610426 bytes, checksum: 538cfee8d0c314f1cf2b2aad936f610d (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar a influência de pinos intra-radiculares préfabricados sobre a resistência de dentes anteriores tratados endodonticamente, debilitados e restaurados com resina composta, bem como estudar o padrão de fratura. Para isto, oitenta incisivos centrais superiores foram divididos em oito grupos experimentais - dentes com duas cristas marginais removidas: restaurados com compósito odontológico (G1), pino pré-fabricado metálico e compósito (G2) e pino de carbono e compósito (G3); dentes com uma das cristas marginais removidas: restaurados com compósito odontológico (G4), pino metálico mais compósito (G5) e pino de carbono mais compósito (G6); dentes somente com acesso endodôntico restaurados com compósito odontológico (G7); e dentes íntegros como controle (G8). Após a inclusão, dez espécimes de cada grupo foram submetidos ao carregamento tangencial de compressão numa Máquina Universal de Ensaios na velocidade de 0,5mm/min, sob o ângulo de 135°. As médias dos valores de resistência à fratura expressos ~m Kgfforam: G8 = 101,80 (:1: 27,81); G1 = 99,09 (:1: 18,57); G7 = 96,33 (:1: 27,03); G5 = 93,76 (:1: 6,19); G3 = 91,88 (:1: 15,98); G4 = 83,50 (:1: 26,76); G2 = 80,45 (:1: 15,89). A análise estatística não demonstrou diferença significativa entre os grupos (ANO V AlDuncan; a = 0,05). Deste modo, conclui-se que: pinos intra-radiculares não reforçaram dentes anteriores tratados endodonticamente; o fator crista marginal não influenciou na resistência à fratura de dentes anteriores restaurados com resina composta. A avaliação do padrão de fratura demonstrou forte correlação entre presença de pinos intra-radiculares - de carbono ou metálicos - e fraturas radiculares longitudinais (X2 / ~ = 0,66; p < 0,01) / Abstract: The aim of this study was to evaluate the influence of intra-radicular prefabricated posts on the resistance of endodontically treated weakened teeth, restored with composite resin, as well as to study the fracture pattem. Eighty upper central incisors were divided into eight experimental groups - teeth with two marginal bridges removed: restored by composite resin (G 1), metallic prefabricated post plus resin (G2) and carbon fiber post plus resin (G3); teeth with one of the marginal bridges removed: restored by composite resin (G4), metallic post plus resin (G5) and carbon fiber post plus resin (G6); teeth only with endodontic access and restored by composite resin (G7); and sound teeth as control (G8). After the inclusion, ten . specimens of each group were submitted to the compressive force in an Universal Te.sting Machine under 0,5mm/min of velocity and an angle of 135 degrees. The averages ofthe resistance values expressed in Kgfwere: G8 = 101,80 (::I:: 27,81); G1 = 99,09 (::I:: 1.8,57); G7 = 96,33 (::I:: 27,03); G5 = 93,76 (::I:: 6,19); G3 = 91,88 (::I:: 15,98); G4 = 83,50 (::I:: 26,76); G2 = 80,45 (::I:: 15,89). The statistical analysis didn't demonstrate significant difference among the groups (ANO V A/Duncan; a = 0,05). This! results permitted the following conclusions: intra-radicular posts were not able to reinforce endodontically treated teeth; the variable marginal bridge didn't show influence in the fracture resistance of teeth restored with composed resin. The evaluation of the fracture pattem demonstrated strong correlation among presence of intra-radicular posts - metallic or carbon fiber - and radicular longitudinal fractures (X2 / ~ = 0,66; p < 0,01) / Mestrado / Dentística / Mestre em Clínica Odontológica
38

Avaliação físico-química e biológica de materiais obturadores de canais radiculares de dentes decíduos / Physical-chemical and biological materials shutters of endodontic materials for primary teeth

Pilownic, Katerine Jahnecke 30 March 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-14T11:52:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação físico-química e biológica de materiais obturadores de canais.pdf: 823655 bytes, checksum: 3df9352cfe64e96e468f59a462418581 (MD5) / Made available in DSpace on 2017-06-14T11:52:41Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação físico-química e biológica de materiais obturadores de canais.pdf: 823655 bytes, checksum: 3df9352cfe64e96e468f59a462418581 (MD5) Previous issue date: 2015-03-30 / Sem bolsa / Este estudo avaliou, a radiopacidade, o pH, a citotoxicidade e o efeito antimicrobiano de um material experimental à base de MTA para obturação de dentes decíduos. Também foram avaliados: Vitapex, Óxido de zinco e eugenol (OZE), e Calen espessado com óxido de zinco. A radiopacidade dos materiais foi comparada a uma escala de alumínio com variação de 0,5 a 5 mm, utilizando sensor digital, com distância focal e tempo de exposição padronizados. A mensuração do pH foi realizada em água deionizada, em períodos entre 1 hora e 30 dias. A viabilidade celular foi avaliada em fibroblastos gengivais humanos, expostos aos materiais por 1, 3 e 7 dias, através do teste de MTT. A atividade antimicrobiana dos materiais foi testada sobre uma cepa de Enterococcus faecalis, através do teste de contato direto. Foi realizada ainda, a avaliação do efeito antimicrobiano sobre biofilme de uma pasta de hidróxido de cálcio; iodofórmio; Vitapex; OZE, e Calen espessado com óxido de zinco. Amostras de biofilme misto foram suspensas em BHI e incubadas, em condições anaeróbicas, usando discos de hidroxiapatita como substrato por 21 dias. Os espécimes foram colocados em contato com os materiais em períodos experimentais de 7 e 30 dias. A porcentagem de bactérias mortas no biofilme foi determinada em microscopia confocal de varredura a laser. Os resultados de radiopacidade mostraram que o material experimental apresentou 3,28 mmAl, valor estatisticamente inferior ao apresentado pelos demais materiais (p<0,05). O material experimental e o Calen espessado com óxido de zinco apresentaram valores de pH >12 enquanto que o cimento de OZE e o Vitapex mostraram valores menores (p>0,05). As células expostas a extratos de Vitapex apresentaram maior viabilidade em todas as concentrações, enquanto que as células expostas aos extratos de OZE apresentaram menor viabilidade (p<0,001). O material à base de MTA e a pasta Calen foram estatisticamente semelhantes (p= 0,115). O teste de contato direto revelou que o material experimental a base de MTA eliminou E. faecalis após 4 horas de contato.O Vitapex foi o material de maior eficácia sobre o biofilme misto. Após 30 dias, apenas 49.49% do volume do biofilme estava viável. Houve diferença significativa entre os materiais em relação ao efeito sobre o biofilme (F = 73,073, p= 0,00). Conclui-se que o MTA experimental apresenta propriedades satisfatórias para emprego como material obturador de dentes decíduos. / The aim of this study was to evaluate radiopacity, pH, cytotoxicity and antimicrobial effect of an experimental MTA-based material comparing to zinc oxide eugenol (ZOE) cement, Calen paste thickened with zinc oxide, and Vitapex. The radiopacity of materials was compared to graduated aluminum stepwedge ranging from 0.5 to 5 mm using a digital sensor with standardized focal distance and exposure time. The measurement of pH was performed in deionized water in periods between 1 hour and 30 days. Cell viability was evaluated in human gingival fibroblasts exposed to materials for 1, 3 and 7 days through the MTT assay. Mixed-species biofilm samples were suspended in BHI and incubated in anaerobic conditions using sterile hydroxyapatite disks as substrate for 21 days. The specimens were placed in contact with the tested materials for experimental periods of 7 and 30 days. The percentage of killed bacteria within biofilm was determined by confocal laser scanning microscopy. The antimicrobial activity of the materials was tested on a strain of Enterococcus faecalis, through direct contact test. The results of radiopacity showed that the experimental MTA presented 3.28 mmAl but statistically lower than that presented by the other materials (p<0.05). Experimental MTA based material and Calen thickened with zinc oxide had pH> 12 while ZOE and Vitapex had lower values (p>0.05). Cells exposed to extracts from Vitapex showed the highest viability rate at all concentrations, whereas cells exposed to ZOE extracts displayed the lowest viabilityrate (p<0.001). MTA- based material and Calen paste were statistically equivalent (p = 0.115). Experimental MTA killed E. faecalis effectively after 4 hours of exposure. Vitapex was the most effective material against biofilm. After 30 days of incubation with Vitapex, 49.59% biofilm volume was viable. There were significant differences in the killing ratio between different materials (F = 73.073, p= 0.00). In conclusion, experimental MTA- based material has satisfactory properties for use as endodontic filling material.
39

Avaliação da biocompatibilidade e análise da alteração de cor dentária induzida por diferentes materiais obturadores de canais radiculares de dentes decíduos / Biocompatibility evaluation and analysis of color alteration induced by endodontic materials used in primary teeth

Pilownic , Katerine Jahnecke 02 May 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-12T13:30:51Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação da biocompatibilidade e análise da alteração de cor dentária.pdf: 1042640 bytes, checksum: 0da5b4e73e0f7ad28fabb01356212f82 (MD5) / Made available in DSpace on 2017-07-12T13:30:51Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação da biocompatibilidade e análise da alteração de cor dentária.pdf: 1042640 bytes, checksum: 0da5b4e73e0f7ad28fabb01356212f82 (MD5) Previous issue date: 2017-05-02 / Sem bolsa / Este estudo avaliou a biocompatibilidade de diferentes materiais obturadores de canais radiculares de dentes decíduos e o seu potencial de alteração de cor. Foram avaliados os seguintes materiais: um material à base de MTA, um material à base de hidróxido de cálcio e iodofórmio (Vitapex), Óxido de zinco e eugenol (OZE), e um material à base de hidróxio de cálcio (Calen) espessado com óxido de zinco (ZO). Para a avaliação da biocompatibilidade, os materiais foram inseridos em tubos de polietileno e implantados no tecido subcutâneo dorsal de quinze ratos Wistar (Rattus norvegicus). Após 15, 30 e 60 dias, os animais foram eutanasiados, os tubos e tecidos circundantes foram removidos e histologicamente processados. As amostras foram avaliadas quanto à intensidade da resposta inflamatória, a espessura da cápsula fibrosa, presença de calcificação e células gigantes. Para a análise do potencial de discoloração, setenta e cinco blocos cubóides de esmalte-dentina foram preenchidos com os diferentes materiais obturadores e selados com ionômero de vidro fotoativado. A alteração de cor (?E00) foi calculada baseada nas coordenadas de cor medido com o espectrofotômetro (VITA Easyshadecompact) antes e depois da inserção dos materiais e após 1 semana, 1, 3, 6 e 9 meses. A alteração de cor ?E00 foi calculada pelo CIEDE 2000 para cada espécime a partir do baseline. Os resultados do teste de biocompatibilidade mostraram que os materiais apresentaram decréscimo na severidade da inflamação a partir de 30 dias. Da mesma forma, em todos os grupos, a cápsula fibrosa, inicialmente espessa, se tornou mais delgada ao longo do período experimental. Células gigantes foram observadas em todos os grupos experimentais principalmente no período de 15 dias, enquanto a ocorrência de calcificação foi observada com mais frequência no grupo Calen+ZO. O teste de avaliação da capacidade de indução de alteração de cor revelou que o tempo teve efeito nos valores de ?E00 (p <0,0001), assim como os materiais (p = 0,004). As interações entre tempo e os materiais provocaram alterações de (?E00) (p < 0,0001). O material à base de MTA apresentou menores valores de alteração de cor (?E= 3,02) ao longo do tempo enquanto o óxido de zinco e eugenol demonstrou os maiores valores (?E= 5,42) (p= 0,018). O material à base de MTA apresenta propriedades satisfatórias podendo ser uma alternativa aos materiais obturadores convencionais, para utilização em canais radiculares de dentes decíduos. / The aim of this study was to evaluate the biocompatibility and discoloration potential of experimental MTA-based endodontic filling material in comparison to zinc oxide eugenol (ZOE) cement, Calen paste thickened with zinc oxide, and Vitapex. In the biocompatibility assay, the materials were introduced into polyethylene tubes and implanted into the dorsal subcutaneous tissue of fifteen Wistar rats (Rattus norvegicus). After 15, 30 and 60 days, the animals were euthanized, the surrounding tubes and tissues were removed and processed for histopathological evaluation. The samples were analyzed for the intensity of the inflammatory response, the thickness of the fibrous capsule, presence of calcification and giant cells. For the analysis of discoloration potential, seventy-five cuboidal enamel-dentin blocks were filled with different endodontic filling materials and sealed with photoactivated glass ionomer cement. Standardized color measurements were performed using a spectrophotometer (Vita Easyshade, Vita-Zahnfabrik, Oberding, Germany) and expressed in ?E*00 units at the following intervals: prior to and after placement of the filling and after 1 week,1 month, 3 months, 6 months, and 9 months. The results of biocompatibility showed the materials tested, as well as the control, had a lower inflammation severity in 30 and 60 days in relation to 15 days. Likewise, the thickness of fibrous capsule in all groups of materials in 15 days was thick and decreased over time. It was possible to observe the presence of giant cells in all groups, mainly in 15 days. The presence of calcification was observed around implantation sites in all groups, but more frequently in Calen + ZO samples. The findings of discoloration potential exhibited the time had a significant effect on color variation values (?E*00) (p <0.0001).The effect of the materials on color variation (?E*00) was also statistically significant (p = 0.004). Interactions between time and materials demonstrated a significant effect on the values (?E*00) (p <0.0001). The MTA-based experimental material showed the smallest color variation throughout the experimental time (?E*00= 3.02), where as the zinc oxide and eugenol cement (ZOE) showed the highest darkening (?E*00= 5.42) (p = 0.018). ).In conclusion, experimental MTA-based material has satisfactory properties for use as endodontic filling material.
40

Influência do momento da obturação definitiva do canal radicular no reimplante dentário imediato

Gulinelli, Jéssica Lemos [UNESP] 22 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-22Bitstream added on 2014-06-13T20:21:53Z : No. of bitstreams: 1 gulinelli_jl_dr_araca.pdf: 1176357 bytes, checksum: 20c724a168a2bc08f8f0a051ec571d3f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O tratamento endodôntico é um passo importante no tratamento do reimplante dentário e o momento da obturação definitiva do canal radicular ainda não está bem estabelecido. A proposta deste trabalho é avaliar o processo de reparo no reimplante imediato de dentes de macaco após o emprego de curativo de demora de hidróxido de cálcio [Ca(OH)2] por 30 e 180 dias seguido da obturação definitiva com cimento à base de Ca(OH)2 (Sealapex®) por meio de análise histomorfométrica. Os incisivos laterais superiores e inferiores de quatro macacas Cebus Apella foram extraídos, mantidos em soro fisiológico por 15 minutos, reimplantados e contidos com resina composta e fio de aço por 10 dias. No Grupo I, 10 dias após o reimplante, iniciou-se a terapia endodôntica, colocação do curativo de hidróxido de cálcio que foi mantido por 30 dias e a obturação do canal radicular foi finalizada aos 40 dias após o reimplante dentário. No Grupo II, o curativo de Ca(OH)2 permaneceu por 180 dias com uma troca aos 90 dias antes da obturação definitiva dos canais radiculares. A eutanásia dos animais foi realizada após nove meses do reimplante dentário. Em todos os grupos, a reinserção epitelial localizou-se na junção cemento-esmalte ou muito próxima a ela, o ligamento periodontal se apresentou organizado e as reabsorções radiculares de superfície eram de pequena extensão e profundidade reparadas por cemento neoformado. Não houve diferença estatisticamente significativa quanto à reabsorção radicular entre os grupos. No reimplante imediato a obturação definitiva do canal radicular pode ser realizada aos 30 dias não necessitando de longo período de curativo de Ca(OH)2. / The endodontic treatment is important for treatment of tooth reimplantation but the period for definitive root canal filling is not still established. The aim of this study is to evaluate the healing process of immediate reimplantation of monkey teeth after calcium hydroxide curative [Ca(OH)2] for 30 and 180 days followed by definitive obturation with Ca(OH)2 cement (Sealapex®) through histomorphometric analysis. The superior and inferior lateral incisors of four female monkeys Cebus Apella were extracted, stored in saline for 15 minutes, reimplanted, and splinted with composite resin and steel wire during 10 days. In the Group I, the endodontic treatment began 10 days after tooth reimplantation with calcium hydroxide curative for 30 days and root canal filling at 40 days after reimplantation. In the Group II, the Ca(OH)2 curative remained during 180 days with a change to the 90 days before root canal filling. The euthanasia of the animals was carried out after 9 months of tooth reimplantation. All groups exhibited epithelial reinsertion at the cementoenamel junction or near, organized periodontal ligament and root surface resorptions with minor extension and depth that were repaired by neoformed cement. There was no statistically significant difference for root resorption among the groups. The root canal filling can be performed earlier without a long period of Ca(OH)2 curative for immediate reimplantation.

Page generated in 0.0434 seconds