• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Vattenkvalitet : Underlag för förbättring av vattenkvalitet / Water quality : Basis for improvment of water quality

Pettersson Nordal, Gustav, Lindström, Hampus January 2015 (has links)
Dricksvattnet ombord på Sjöfartshögskolans fartyg Calmare Nyckel har vid tidigare provtagning visat på undermålig kvalitet. Orsaken till detta har inte undersökts innan. I detta arbete undersöks och identifieras orsaken och ett underlag för förbättring av vattenkvaliteten har tagits fram. Underlaget omfattas också av en arbetsbeskrivning för ombyggnation av färskvattensystemet och ett underlag för installation av en färskvattenproducerande anläggning. För att kontrollera vattenkvaliteten ombord genomfördes vattenprover och en undersökning av färskvattensystemet med endoskop. Resultaten analyserades sedan och ett åtgärdsprogram för förbättring av vattenkvaliteten har rekommenderats. Det nuvarande färskvattensystemet undersöktes och outnyttjade anläggningsdelar identifierades. En arbetsbeskrivning för demontering av ovan nämnda anläggningsdelar togs fram. Sjöfartshögskolan hade förvärvat en begagnad färskvattenanläggning vilken undersöktes för att avgöra om den gick att använda ombord på Calmare Nyckel. Undersökningen visade att anläggningen inte gick att använda och arbetet fortsatte med att utveckla en offert på en färskvattenproducerande anläggning som Sjöfartshögskolan beställde 2009. Ett underlag för installation av den färskvattenproducerande anläggningen togs fram och innehåller montageritningar, arbetsbeskrivningar, materialbehov, plan för monteringsarbetet och resursbehov. Metoden och åtgärdsprogrammet kan i framtida undersökningar fungera som hjälpmedel vid behov av att förbättra vattenkvaliteten ombord på liknande fartyg. / Drinking water onboard Kalmar Maritime Academy’s ship Calmare Nyckel has on previous sampling demonstrated insufficient quality. The reason for this has not been investigated before. This study examines and identifies the cause for the substandard water quality and support material for improvement has been developed. The material also contains a job description for rebuilding of the fresh water system and documents regarding installation of a freshwater generator. Water samples and examination of the fresh water system with endoscope was performed to verify the water quality onboard the ship. The results were analysed and a plan for improvement of water quality was recommended. The current fresh water system was investigated and unused components were identified. A description for removing the mentioned components was made. Kalmar Maritime Academy had acquired a used freshwater generator which was examined to determine whether it could be used onboard Calmare Nyckel. The examination revealed that it could not be used and the study proceeded to develop a quotation on a freshwater generator that Kalmar Maritime Academy had ordered in 2009. Material for the installation of the freshwater generator was created and includes assembly drawings, job descriptions, material requirements, plan for the assembly work and resource needs. The method and plan may in future investigations be used as aids to the improvement of water quality onboard similar vessels.
2

Är återanvändning av renat avloppsvatten lösningen på Halmstad kommuns årliga vattenbrist?

Thorstensson, David January 2019 (has links)
Due to an increased population and future risks of drought in Halmstad municipality, the pres- sure on water reservoirs increases. To address future challenges and decrease the dependency on large amounts of precipitation, Laholmsbuktens Water and Sewer as started to investigate the opportunity to re-infiltrate purified wastewater. Therefore, I studied the possibility to re- infiltrate purified wastewater into a pit and produce drinking water. To investigate the possibil- ity, I selected to conduct a literature study. I started to compile the limit values for drinking water and outflowing concentrations from Western shore wastewater treatment plant for all the substances I studied. Then I investigated the pits purification capacity, through comparing the concentration after purification of the pit with limit values I could establish which substances required further purification. The pits area requirement and suitable further purification treat- ment for the studied substances were also examined. The investigated substances are chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (tot-N), total phos- phorus (tot-P), ammonium, suspended solids, 7 heavy metals, 10 pharmaceuticals and 11 Poly- and perfluoroalkyl substances (PFAS). The results showed that COD, BOD, diklofenak, kar- bamazepin, zink and all PFAS-substances required further purification before the water entered the pit. The most suitable further purification for the studied substances established to be ultra- filtration as pre-treatment to reverse osmosis and it requires four 1.5 hectare basins to infiltrate the desired amount of water. Therefor the conclusion of this study is, that it is possible to create drinking water by infiltrating wastewater from Western shore wastewater treatment plant into the specific pit. However, the wastewater requires ultrafiltration and reverse osmosis treatment before infiltration in order to remove contamination that will not be removed by the infiltration process.
3

Ultrasonication of Spiral Wound Membranes to Mitigate Fouling in Reverse Osmosis / Ultraljudsbehandling av spirallindat membran för att reducera igenslamning vid omvänd osmos

Diklev, Eliot January 2022 (has links)
Syftet med den här studien var att undersöka en alternativ slamningsreducerande teknik till spolning, som effektivt kan ta bort biologisk påväxt. Ultraljud undersöktes som en möjlig metod för att ta bort igenslamningen från omvänd osmos med ett spirallindat membran. Tidigare forskning har föreslagit att ultraljud skulle kunna vara effektivt på platta membran men inte på spirallindade membran, på grund av packningsdensiteten som spirallindan medför. Därför genomfördes inom denna studie försök med spirallindade membran och ultraljud, för att få en förståelse av dess effekter inom det spirallindade membranet. För det första undersöktes tidsberoendet av ultraljud, vilket visade liknande resultat som tidigare forskning, att ultraljudet uppnådde effekt inom några minuter. För det andra behandlades två membran en gång om dagen under 12 dagar, med undantag för dag 6 och 7. Ett behandlades med ultraljud och ett med spolning, och den mikrobiologiska kontamineringen i permeatet analyserades sedan. Det ultraljudsbehandlade membranet producerade mindre kontaminering under de 12 dagarna. Det krävs dock fler experiment och analyser för att bekräfta detta, eftersom tidsbegränsningar inte möjliggjorde repetitioner. En ekonomisk utvärdering genomfördes också för att undersöka möjligheten att implementera ultraljud i kommersiell skala. Den ekonomiska aspekten är en avvägning mellan vattenkostnad och energikostnad, som är beroende av geografiskt läge. Överlag indikerar resultaten att det sparade vattnet kostar mer än den energi som krävs, vilket är fördelaktigt för implementering av ultraljudsbehandling. Sammanfattningsvis visade ultraljudsbehandlingen bättre resultat än spolning inom några minuter, och hade även en ekonomisk fördel, men kostnaden för energi till vatten är beroende av geografisk plats. / The purpose of this study was to investigate an alternative fouling mitigation technique to flushing, that can efficiently remove biological fouling. Ultrasound was investigated as a possible method of removing fouling from a reverse osmosis spiral wound membrane. Previous research had suggested ultrasound to be efficient on flat sheet membranes but not on spiral wound membranes, due to the packing density. Therefore, this study conducted experiments on spiral wound membranes with ultrasound, as to get an understanding of its effects within the spiral wound membrane. Firstly, the time dependency of ultrasound was investigated, and showed similar results to that of previous research, that the ultrasound was efficient within a matter of minutes. Secondly, two membranes were subject to treatment once a day over the span of 12 days, with an exception for days 6 and 7. One was treated with ultrasound and one with flushing, and the microbiological contamination in the permeate was then analysed. The ultrasonically treated membrane produced less contamination throughout the 12 days. However, more experiments and analysis would be required to confirm this, as time constraints did not allow for repetitions. An economic assessment was also performed, as to evaluate the feasibility implementing ultrasound on a commercial scale. This is a weigh-off between water cost and energy cost, which is dependent on geographical location. Overall, the results indicate that the water saved costs more than the energy required though, which is favourable for the implementation of ultrasonic treatment. To conclude, the ultrasonic treatment showed better results than flushing within a matter of minutes, and also economically had an advantage but the cost of energy to water is relative to geographical location.
4

Avsaltning av brackvatten som lösning för Ålands framtida vattenförsörjning

Skoglund, Anna, Skotte, Maja, Fors, Alexander, Jeppsson Stahl, Fanny, Löf, Harald, Renberg, Johanna January 2019 (has links)
Målet med detta projekt var att jämföra nuvarande dricksvattenproduktion på Åland med ett eventuellt kompletterande avsaltningsverk, samt undersöka om det är rimligt att uppföra ett sådant. Detta genomfördes genom informationsinsamling i en litteraturstudie och jämförelse mellan nuvarande vattenverk och ett eventuellt avsaltningsverk i en beslutsmatris. Kategorier som ansågs relevanta för jämförelsen identifierades och sedan utvecklades dessa genom att identifiera parametrar som byggde upp kategorierna. Den insamlade informationen användes sedan för att klassa de olika parametrarna inom kategorierna och en samlad bedömning gjordes. De kategorier som undersöktes var: dricksvattenkvalitet, miljökonsekvenser, energiförbrukning och kostnader samt tillräcklig och säker dricksvattentillgång. Det eventuella kompletterande avsaltningsverket ansågs kunna konkurrera med nuvarande vattenproduktion med avseende på alla dessa fyra kategorier och metoden bedömdes vara en bra grund för jämförelsen. För att utveckla projektet i framtiden rekommenderades modellering och en pilotstudie.
5

Analys och jämförelse av två pilotanläggningar med olika sammansättning av membran : Vid rening av processvatten från industri

Nygren, Astrid, Slättengren, Robin January 2017 (has links)
Vattentillgången på Öland har under en lång tid varit mycket ansträngd och har kommit till en punkt då det inte längre är hållbart. För att nå en mer långsiktig lösning planerar Mörbylånga kommun med hjälp av Norconsult att bygga ett vattenreningsverk. Detta kommer att rena bräckt vatten ifrån Kalmarsund samt processvatten ifrån Guldfågeln AB, som tillsammans kommer att fungera som ett komplement till det redan befintliga sötvattnet. Två pilotanläggningar som renar processvatten ifrån en industri, genom ultrafilter kombinerat med omvänd osmos, har utvärderats. En metod för att sammanställa de kostsamma driftparametrarna elförbrukning, förbrukning av kemikalier samt underhållsarbete vid drift och membranens inköpskostnad genom en LCC har tagits fram. Denna metod ger en ungefärlig totalkostnad per kubikmeter av det renade vattnet. Även vattenkvaliteten på ingående råvatten, vattnet mellan membranen samt det utgående vattnet har analyserats. Detta för att undersöka att processerna fungerar som den ska, samt ge en indikation på vilka mineraler som kommer att behöva tillsättas i efterhand. Pilot B blir ca fem kronor dyrare per kubikmeter jämfört med Pilot A. De totala kostnaderna, 9.70 – 10.79 kr/m3 för Pilot A och 15.19 – 15.28 kr/m3 för Pilot B, kan jämföras med den nuvarande kostnaden för en kubikmeter vatten i Mörbylånga, 15 kr/m3, samt den kostnad kommunen betalade sommaren 2016 för att frakta vatten i tankbilar, 70 kr/m3.
6

Rening av rökgaskondensat i ett fjärrvärmeverk : Återanvändning av rökgaskondensat som spädvatten / Purification of flue gas condensate in heat plants : Reuse of flue gas condensate as feed water

Dabrowski, Patrik January 2017 (has links)
Arvika Fjärrvärme AB is manufacturing and distributing district heating to around 300 customers in Arvika. Heat production consists of a BFB boiler fed with GROT fuel (branches and peaks) and delivers a maximum power of 30 MW. In order to operate the plant, an average of 60 m3 of water per day is consumed from the urban water network. The water consumption is divided between water treatment, sooting and process cooling. In the processes, sulfur is dosed to obtain a more complete combustion of the hazardous flue gases that can occur. This is a result of previous thesis made for Arvika fjärrvärme. GROT is a fuel that contains high levels of moisture, which means that a high amount of condensate is formed during combustion, averaging 100 m3 per day. At present, condensate is sufficient to meet the condensate limit values ​​to be flushed into the drain. This is achieved by sand filtration and pH neutralization. Today, Arvika heat production is equipped with a purification stage for the feed water consisting of a softening filter and membrane filtration. This creates good conditions for cleaning the condensate and recirculating it in the process. Questions for this study are which hazardous substances the condensate can contain and how the condensate composition affected due to sulfur dosage. In addition, Arvika fjärrvärme wants to find out whether the purified condensate can replace the use of the urban water and, finally, if the condensate can be purified and used as feed water in the process. The execution of the work was based on a full-scale attempt in two operating cases of 9 and 18 MW. The tank collecting all condensate after purification in the sand filter and pH neutralization was coupled to the feed water purification stage. Thus, the condensate was pumped and purified in the softening filter and membrane filter. Assay substrates were collected before and after purification of the condensate. In addition to the topics that Arvika investigates, high levels of alkalinity were found in the condensate. The sulfur dosage that Arvika technology works with can be the cause of the high concentrations of sulphate. However, it appears that both the sulfate and alkalinity were purified in the membrane filter. The amount of condensate formed cannot completely replace the entire water requirement, but definitely large parts. The condensate can be used as feed water based on the retention rate for all substances. However, it appears that two substances, chloride and sulphate can create problems for the membrane filter. To investigate this, the condensate should be tested over a longer period of time to see the affect the chloride as well as the sulphate in the long run. / Arvika Fjärrvärme AB bedriver produktion och distribution av fjärrvärme till ca 300 kunder runt om i Arvika. Värmeproduktionen består av en BFB-panna som matas med bränslet GROT (grenar och toppar) och levererar en maxeffekt på 30 MW. För att driva anläggningen förbrukas i snitt 60 m3 vatten per dag från stadsvattennätet för spädvattenförberedning, sotning och processkylning. I denna typ av värmeproduktion som Arvika Fjärrvärme bedriver doseras svavel. Detta är ett resultat av ett tidigare examensarbete som visade att vid en dosering av svavel bildas det färre farliga rökgaser som kan uppstå vid förbränningen. GROT är ett bränsle som innehåller höga halter fukt vilket innebär att höga mängder kondensat bildas vid förbränningen, i snitt 100 m3 per dag. I dagsläget renas kondensatet tillräckligt för att möta de gränsvärden för att kondensatet ska få spolas ner i avloppet. Detta uppnås genom en sandfiltrering och pH-neutralisering. Idag är Arvika Fjärrvärme utrustade med ett reningssteg för spädvattnet bestående av ett avhärdningsfilter samt membranfilter. Detta skapar goda förutsättningar för att rena kondensatet och återcirkulera det i processen. Funderingar som uppstår är vilka farliga ämnen som kondensatet kan innehålla samt hur kondensatsammansättningen påverkas av svaveldoseringen. Dessutom ställer sig värmeverket frågan om det renade kondensatet kan ersätta förbrukningen av stadsvattnet och slutligen om kondensatet kan renas och användas som spädvatten i processen. Genomförandet av arbetet baserades på ett fullskaligt försök under två driftfall på 9 samt 18 MW. Tanken som samlar upp allt kondensat efter rening i sandfiltret och pH neutraliseringen kopplades på i steget för spädvattenrening. På så sätt pumpades kondensatet igenom och renades i avhärdningsfiltret samt membranfiltret. Analysunderlag samlades in före samt efter rening av kondensatet. Förutom de ämnen som Arvika fjärrvärme undersöker förkommer höga halter alkalinitet i kondensatet som bidrar till bildning av pannsten. Svaveldoseringen som Arvika fjärrvärme jobbar med kan vara orsaken till de höga koncentrationerna av sulfat. Det visar sig dock att både sulfatet och alkaliniteten renas bort i membranfiltret. Mängden kondensat som bildas kan inte helt ersätta hela vattenbehovet men definitivt stora delar. Kondensatet kan användas som spädvatten om retentionsgraden för ämnena anses hög nog. Det visar sig dock att två ämnen, klorid och sulfat, kan skapa problem för membranfiltret. För att undersöka detta bör kondensatet testas under en längre tidsperiod för att se vilken påverkan klorid och sulfat har i längden.

Page generated in 0.0259 seconds