• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • Tagged with
  • 35
  • 35
  • 35
  • 29
  • 29
  • 28
  • 15
  • 15
  • 14
  • 13
  • 13
  • 13
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo eletroquímico e desenvolvimento de novas metodologias eletroanalíticas para a determinação de antidepressivos tricíclicos e neurotransmissores / Electrochemical study and development of new electroanalytical methodologies for the determination of tricyclic antidepressants and neurotransmiters

Renata Alves de Toledo 17 February 2006 (has links)
Neste trabalho, são abordados os estudos eletroquímicos e químico-quânticos, bem como o desenvolvimento de metodologias analíticas para o antidepressivo tricíclico imipramina e para o neurotransmissor dopamina. Os experimentos foram realizados em solução tampão Britton Robinson (BR) 0,10 mol L-1 no pH de melhor resposta analítica para os referidos compostos. Com base nos parâmetros eletroquímicos extraídos das técnicas de voltametria cíclica e de onda quadrada, utilizando-se um eletrodo de grafite-poliuretana (GPU), foi possível diagnosticar o grau de reversibilidade das reações, a presença ou não de processos de adsorção e também o número de prótons e elétrons envolvidos nas reações eletroquímicas. Quanto aos cálculos químico-quânticos, a representação gráfica do HOMO (orbital molecular de mais alta energia ocupado) e os cálculos das cargas atômicas derivadas do potencial eletrostático forneceram uma estimativa do provável sítio de oxidação dos compostos. Os resultados indicaram que a reação de oxidação da imipramina é irreversível e dependente da adsorção do reagente na superfície do eletrodo, ocorrendo a formação subseqüente de um dímero em uma etapa química posterior à transferência de dois elétrons e um próton. O provável sítio de oxidação da molécula abrange a região do átomo de nitrogênio do anel, salientando que após a transferência de dois elétrons há uma deslocalização de cargas pelo anel aromático, fato este que sugere a formação do dímero na posição 2. Paralelamente, experimentos de eletrólise a potencial controlado foram realizados com o objetivo de gerar produtos de reação para serem analisados pela técnica de espectroscopia de massa com ionização por electrospray (ESI-MS). Tomando-se por base os resultados obtidos pelas técnicas voltamétricas, pelos cálculos químico-quânticos e pelos espectros de massa, foi sugerido o provável mecanismo de oxidação da imipramina nas condições estudadas. A metodologia analítica desenvolvida para a imipramina é rápida, sensível e exata para a análise de rotina em comprimidos de Tofranil®. A sensibilidade alcançada pela metodologia permitiu ainda a análise direta de concentrações plasmáticas terapêuticas do antidepressivo e de seu metabólito (desipramina) em amostra de soro humano sintético. No entanto, a seletividade da metodologia ficou comprometida pela proximidade dos potenciais de pico dos dímeros formados após a oxidação da imipramina (-41 mV) e da desipramina (23 mV). A aplicação de um método matemático de deconvolução (Origin 6.0) tornou possível a determinação simultânea da imipramina e da desipramina. A dopamina, por sua vez, é oxidada a dopamina orto quinona em um processo reversível com a adsorção de reagente e produto na superfície do eletrodo. O processo envolve a participação de dois elétrons e dois prótons. A metodologia analítica desenvolvida para a dopamina foi aplicada na análise de rotina em ampolas de Revivan® com boa exatidão e precisão. Além disso, a sensibilidade e a seletividade alcançada pela metodologia resultou na determinação de dopamina em fluído cerebrospinal sintético. A separação dos picos de oxidação da dopamina (Ep = 200 mV) e do ácido ascórbico (Ep = 40 mV) deve-se, provavelmente, às interações eletrostáticas favoráveis entre a superfície do eletrodo de GPU e o ânion ascorbato. De maneira geral, os resultados obtidos foram bastante satisfatórios para as determinações pretendidas, concluindo que o eletrodo de GPU é um material promissor para a análise de moléculas de interesse biológico. / In this work, the electrochemical and quantum-chemical studies are discussed, as well as the development of analytical methodologies for the imipramine tricyclic antidepressant and for the dopamine neurotransmitter. Experiments were performed in 0.10 mol L-1 Britton Robinson (BR) buffer solution at the best analytical response pH for the mentioned compounds. From the electrochemical parameters extracted of cyclic and square wave voltammetric techniques, using a graphite-polyurethane electrode (GPU), it was possible to diagnose the reactions reversible degree, the presence or not of adsorptions processes and also the number of protons and electrons involved in the electrochemical reactions. Concerning to the quantum-chemical calculations, the graphic representation of HOMO (Highest Occupied Molecular Orbital) and the calculation of the atomic charge derived from electrostatic potential provided an estimation of the probable oxidation sites of the compounds. The results indicated that the oxidation reaction of imipramine is reversible and dependent of the reagent adsorption at the electrode surface, occuring the formation of a dimer in a chemical step after the transference of two electrons and one proton. The probable oxidation site of the molecule includes the nitrogen atom region of the ring, emphasizing that after the transference of the two electrons there is a deslocalization of the charges though the aromatic ring, suggesting the formation of the dimeric specie at postion 2. At the same time, experiments of controlled potential electrolysis were carried out in order to generate reaction products to be analysed by electrospray ionization mass espectrosmmetry (ESI-MS). From the results obtained by voltammetric techniques, by quantum-chemical calculations and by mass spectroscopy, it was suggested a probable mechanism for the imipramine oxidation in the studied conditions. The analytical methodology developed for imipramine is fast, sensible and accurate for routine analysis in Tofranil® tablets. The reached sensibility also allowed the direct analysis of therapeutical plasmatic concentrations of the antidepressant and its methabolic (desipramine) in synthetic human serum sample. However, the selectivity of the methodology was compromised by the peak potentials proximity of the dimers formed after the oxidation of imipramine (-41 mV) and of desipramine (23 mV). The application of a deconvolution mathematical xviii method (Origin 6.0) permitted the simultaneous analysis of imipramine and desipramine. On the other hand, dopamine is oxidized to dopamine ortho-quinone in a reversible process with the adsorption of reagent and product at the electrode surface. The process involves the participation of two electrons and two protons. The analytical methodology developed for dopamine was applied in the routine analysis in Revivan® injections with good accuracy and precision. Besides that, the sensitivity and the selectivity reached by the methodology resulted in the determination of dopamine in synthetic cerebrospinal fluid. The separation of the oxidation peaks of dopamine (Ep = 200 mV) and of ascorbic acid (Ep = 40 mV) is probably due to the favorable electrostatic interactions between the GPU electrode surface and the ascorbate anion. In general way, the obtained results were very satisfatory for the desirable determinations, concluding that the GPU electrode is a promissing material for the analysis of biological interest molecules.
22

Determinação eletroanalítica dos herbicidas 2,4-D e metribuzin em amostras de solo utilizando um eletrodo compósito de grafite-poliuretana / Electroanalytical determination of the herbicides 2,4-D and metribuzin in soil samples using graphite-polyurethane composite electrode.

Fernanda Ramos de Andrade 18 July 2008 (has links)
O presente trabalho apresenta um estudo eletroquímico da redução dos herbicidas 2,4-D e metribuzin bem como o desenvolvimento de metodologias analíticas para determinação destes compostos em amostras naturais. Os experimentos foram realizados sobre eletrodo compósito de grafite-poliuretana (GPU) utilizando a técnica de voltametria de onda quadrada (SWV). A técnica de Voltametria Cíclica (VC) foi utilizada para diagnosticar o grau de reversibilidade da reação de redução dos herbicidas assim como a natureza do transporte da material eletroativo para a superfície do eletrodo de GPU. Os eletrólitos suportes utilizados nos experimentos foram: tampão Britton-Robinson (BR) para o 2,4-D e água acidificada com H2SO4 0,1 mol L-1 para o metribuzin, ambos em pH 2. Os resultados indicaram que tanto o 2,4-D quanto para o metribuzin, apresentam um único pico de redução com características de processo irreversível controlado pela adsorção de reagente na superfície do eletrodo. Os parâmetros da técnica de SWV (freqüência, amplitude e incremento de varredura), bem como o tempo e potencial de acumulação foram otimizados para obtenção de maior sensibilidade analítica. Curvas analíticas dos dois herbicidas foram obtidas no intervalo de 1,5 a 12 µmol L-1 para os dois herbicidas. Os limites de detecção (LD) e de quantificação (LQ) obtidos para o 2,4-D, foram de 17,6 µg L-1 e 58,6 µg L-1, respectivamente. Para o metribuzin, o LD foi de 1,67 µg L-1 e o LQ 5,56 µg L-1. A precisão das metodologias desenvolvidas foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 104 % para o 2,4-D e 102 % para o metribuzin. As metodologias eletroanalíticas desenvolvidas para determinação do 2,4-D e do metribuzin, foram aplicadas em um estudo para avaliação do tempo de percolação dos mesmos em dois solos com características distintas. Os resultados indicaram que os dois herbicidas apresentam alta mobilidade nos solos estudados, pois 24 horas após a aplicação já foi possível detectar a presença dos mesmos na solução do solo extraída. Para o 2,4-D, 7 dias após o início do experimento, foram encontrados apenas resíduos de herbicida, enquanto que para o metribuzin obteve-se concentrações próximas a 1 mg L-1, mesmo depois de 14 dias. Após 100 dias do início do experimento observou-se um maior acúmulo de 2,4-D no solo arenoso, que pode ter ocorrido devido ao teor mais elevado de MO do solo argiloso, que proporciona uma quantidade maior de microorganismos no solo e que podem degradar o 2,4-D. Já para o metribuzin pode-se observar que este fica adsorvido nas primeiras profundidades do solo argiloso, possivelmente pelas maiores quantidades de MO e CTC. O eletrodo de GPU com a técnica de SWV apresentou bons resultados no que diz respeito à sensibilidade e ao tempo de análise, sendo uma excelente alternativa ao eletrodo de mercúrio, usualmente utilizado em medidas eletroanalíticas do 2,4-D e metribuzin. Os resultados obtidos com amostras de solo e formulação comercial dos herbicidas são bastante coerentes, considerando a dinâmica da dissipação espacial e temporal dos herbicidas no perfil do solo. / This research presents an electrochemical study of the herbicides 2,4-D and metribuzin reductions and the development of analytical methodologies for the determination of such substances in natural samples. The experiments were done with a graphite-polyurethane composite electrode (GPU) using the square wave voltammetry (SWV). The cyclic voltammetry (CV) was used to evaluate the reversibility degree of the herbicides reductions and thus the transport nature of the electroactive material to the surface of the GPU electrode. The supporting electrolytes used in the experiments were Britton-Robinson (BR) buffer for the 2,4-D and acidified water with H2SO4 0,1 mol L-1 for the metribuzin, both at pH 2. Results indicated that the 2,4-D and metribuzin show one reduction peak reduction with irreversible process characteristics, which are controlled by the adsorption of the reagent in the electrode surface. The SWV technique parameters (frequency, amplitude and scanning increment) and the time and potential of accumulation were optimized in order to obtain the highest analytic sensibility. Analytical curves were obtained from 0,33 mg L-1 to 2,62 mg L-1 for 2,4-D and 0,32 mg L-1 to 4,72 mg L-1 for metribuzin. The detection (LD) and quantification limits (LQ) obtained for 2,4-D were 17,6 µg L-1 and 58,6 µg L-1, respectively. For metribuzin, the LD was 1,67 µg L-1 and the LQ was 5,56 µg L-1. The precision of the developed methodologies was evaluated though its repeatability and reproductibility, besides the accuracy were determined by the relative error. Recovery experiments done by the standard addition method, provided values of 104 % for the 2,4-D and 102 % for the metribuzin. The electroanalytical methodologies developed for the determination of these herbicides were applied in two different soils with distinct characteristics, one sandy and other clayed soil. Results indicate that the herbicides present high mobility in the studied soils and 24 hours after its application it was possible to detect the presence of the herbicides in the soil solution extract. For the 2,4- D, seven days after the beginning of the experiment it was measured only residues, but for the metribuzin it is possible to measure concentrations around 1 mg L-1, even after fourteen days. After 100 days it was observed the highest accumulation of the 2,4-D in the sandy soil, that can be explained by the highest content of OM in the clay soil, which provides a higher content of 2,4-D degrading microorganisms. The herbicide metribuzin was adsorbed in the first layers of the clay soil, possibly due to the higher CTC and OM amounts in the soil profile. The GPU electrode with the SWV technique presented very good results when considered the sensibility and time analyses, being an excellent alternative for the mercury electrode usually used in the electroanalytical measurements of the 2,4-D and metribuzin. The obtained results with soil samples and commercial formulation of the herbicides are very consistent, considering the spatial and temporal dissipation dynamics of the herbicides in the soil.
23

COMPARAÇÃO DE SENSORES ELETROQUÍMICOS PARA DETERMINAÇÃO DE ENXOFRE EM BIODIESEL / COMPARISON OF ELECTROCHEMICAL SENSORS FOR DETERMINATION OF SULPHUR IN BIODIESEL

Costa, Helmara Diniz 06 June 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:46Z (GMT). No. of bitstreams: 1 Dissertacao Helmara.pdf: 1239564 bytes, checksum: f5a4e670235603269ce13bb3db2a2938 (MD5) Previous issue date: 2013-06-06 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Due to the implementation of more restricted environmental regulation laws, the control of pollution agent such as sulfur compounds has provides the development of new analytic methodologies for its quantification on different matrices, including biodiesel fuel. Thus, this work aims to compare three different sensors - film bismuth and mercury film on the surface of a glassy carbon electrode and solid silver amalgam (dental) - for the determination of sulfur in biodiesel, by means of stripping voltammetric cathodic square wave mode (VRC/SW) as supporting electrolyte with a solution of sodium acetate (1,4 mol.Lˉ¹) and acetic acid (0.33 mol.Lˉ¹) in metanol/2-propanol. In general, the mercury film electrode (MFE) has presented the best electrochemical behavior to the definition of peak reduction, being then selected as standard electrode to the measurements. The sulfur quantization on biodiesel samples was performed by adding 70 μL of soybean biodiesel and tallow fatty with TMAH, adding later, aliquots of standard sulfur. The method showed good linearity (0.998), suggesting an average sulfur concentration of 6,870x10ˉ7 (± 6,857x10ˉ⁸) mol.Lˉ¹, within a confidence interval of 95%, to a limit of detection 3,294x10ˉ¹º mol.Lˉ¹ and quantification limit of 1,098x10ˉ9 mol.Lˉ¹. Besides, for the untreated sample, the experimental has provided a LD of 6,54 x 10ˉ9 mol.Lˉ¹. Finally the proposed method has been compared with the results of a collaborative study (ANP 01/2012) of the same sample using the Teste-t de Student, verifying that the proposed method and official methods (EN ISO 20846, EN ISO 20884) are statistically equivalent to a confidence level of 95%, thereby demonstrating the feasibility of the method. / O controle da poluição ambiental tem exigido, cada vez mais, a determinação de enxofre em uma variedade de matrizes. Diferentes métodos analíticos têm sido desenvolvidos para determinação deste analito em biodiesel, empregando várias técnicas, que vão desde a análise cromatográfica aos métodos espectroanalíticos. No presente trabalho são apresentados os resultados da avaliação de diferentes sensores eletroquímicos para determinação de enxofre em Biodiesel, utilizando a técnica voltamétrica de redissolução catódica no modo onda quadrada (VRC/SW) tendo como eletrólito suporte uma solução de acetato de sódio (1,4 mol.Lˉ¹) e ácido acético (0,33 mol.Lˉ¹), em metanol/2-propanol. Foram avaliados três sensores (filme de bismuto e filme de mercúrio na superfície de carbono vítreo, e eletrodo sólido de amálgama de prata dentária) na determinação de enxofre, sendo observado que o eletrodo de filme de mercúrio (EFM) apresentou os melhores resultados relacionados ao comportamento eletroquímico na definição do pico de redução. Portanto, o EFM foi o sensor escolhido para aplicação na amostra de biodiesel. A determinação do analito em Biodiesel foi realizada adicionando-se 70 μL de Biodiesel de Soja e Sebo (01/2012, interlaboratorial) tratado com TMAH, adicionando, posteriormente, alíquotas de padrão de enxofre. O método apresentou uma boa linearidade (0,998), determinando-se assim uma concentração média de enxofre de 3,687 x 10ˉ7± 6,857 x 10ˉ⁸ mol.Lˉ¹, a um intervalo de confiança de 95%, para um limite de detecção de 3,294 x 10-10 mol.Lˉ¹ e limite de quantificação de 1,098 x 10ˉ9 mol.Lˉ¹, o que demonstra uma boa sensibilidade da técnica. Além disso, avaliou-se o estudo sem tratamento da amostra, na qual obteve-se LD de 6,54 x 10ˉ9 mol.L-1. O presente método foi comparado com os resultados de um estudo interlaboratorial (ANP 01/2012) da mesma amostra, utilizando o Teste-t de Student, verificando que o método proposto e os métodos oficiais (EN ISO 20846; EN ISO 20884) são estatisticamente equivalentes a um nível de confiança de 95%, demonstrando assim a viabilidade do método.
24

Tratamento de amostras de cosméticos faciais para análise eletroquímica de cobre, chumbo e zinco

Faria, Lucas Vinicius de 23 February 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-07-20T14:04:12Z No. of bitstreams: 1 lucasviniciusdefaria.pdf: 2100582 bytes, checksum: 25d968a4baa8a369f530d1dff0826872 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-09T12:56:13Z (GMT) No. of bitstreams: 1 lucasviniciusdefaria.pdf: 2100582 bytes, checksum: 25d968a4baa8a369f530d1dff0826872 (MD5) / Made available in DSpace on 2017-08-09T12:56:13Z (GMT). No. of bitstreams: 1 lucasviniciusdefaria.pdf: 2100582 bytes, checksum: 25d968a4baa8a369f530d1dff0826872 (MD5) Previous issue date: 2017-02-23 / Produtos cosméticos como sombra para os olhos, pó compacto e batom são utilizados demasiadamente pela sociedade feminina em busca de uma melhor aparência. Entretanto é importante destacar que nem todos produtos estão isentos de impurezas como metais, os quais podem ser tóxicos ao ser humano. O objetivo deste trabalho foi otimizar um procedimento adequado para o tratamento de amostra de cosméticos faciais (batom, pó compacto e sombra) empregando planejamento de experimentos (Box Behnken e fatorial 32 com triplicata no ponto central) com digestões em chapa de aquecimento e forno micro-ondas utilizando misturas de ácido nítrico e clorídrico concentrados, para a determinação eletroquímica de cobre, chumbo e zinco. Para análise destes metais trabalhou-se com um conjunto de três eletrodos: eletrodo de carbono vítreo modificado com mercúrio (trabalho), Ag/AgCl (referência) e platina (auxiliar). A modificação do eletrodo de carbono vítreo com mercúrio foi feita in situ, isto é, simultaneamente com a deposição dos analitos, sendo necessário o tempo de 300 s para deposição. Parâmetros envolvidos com a etapa de redissolução da voltametria de onda quadrada como frequência, amplitude e incremento de potencial foram otimizados de modo univariado, sendo as condições otimizadas respectivamente (60 Hz, 45 mV e 7 mV). As análises de cobre e chumbo foram feitas simultaneamente utilizando como eletrólito suporte ácido clorídrico 0,1 mol L-1, enquanto que o zinco foi analisado separadamente empregando o tampão acetato 0,1 mol L-1 (pH=4,6) como eletrólito suporte. O forno micro-ondas foi o método escolhido para digestão de todas as amostras de cosméticos faciais, onde as recuperações variaram de 83108%, 67-76% e 75-103% respectivamente para cobre, chumbo e zinco. Os limites de detecção do método para cobre, chumbo e zinco variaram de 0,05-0,36 µg g-1, e os limites de quantificação de 0,36-1,16 µg g-1. Foram analisadas 9 amostras, sendo que as concentrações de Cu, Pb e Zn variaram respectivamente em 14-26,68 µg g-1; 1,31-9,74 µg g-1 e 7,1-42064 µg g1. Para validação dos resultados obtidos eletroquimicamente, empregou-se a F AAS (Cu e Zn) e GF AAS (Pb). A partir de testes estatísticos verificou-se que não houve evidências de diferenças significativas entre o método desenvolvido eletroquimicamente e F AAS, GF AAS com 95% de confiança. Os níveis de concentrações encontrados para os metais ficaram abaixo do nível estabelecido pela sociedade europeia, não oferecendo risco a saúde humana, no que tange aos metais analisados. / Cosmetic products such as eye shadow, compact powder and lipstick are used too much by the feminine society in search of a better appearance. However, it is important to note that not all products are free from impurities such as metals, which can be toxic to humans. The objective of this work was to optimize a suitable procedure for the treatment of facial cosmetic samples (lipstick, compact powder and eye shadow), employing experiment planning (Box Behnken and factorial 32 with triplicate at the central point), With digestion in heating plate and microwave oven using concentrated nitric and hydrochloric acid mixtures, for the electrochemical determination of copper, lead and zinc. For analysis of these metals we worked with a set of three electrodes: mercury modified glass carbon electrode (work), Ag / AgCl (reference) and platinum (auxiliary).The modification of the glassy carbon electrode with mercury was done in situ, that is, simultaneously with the deposition of the analytes, being necessary the time of 300 s for deposition. Parameters involved with the step of redissolution of the square wave voltammetry frequency, amplitude and potential increase were optimized univariate. being the conditions optimized respectively (60 Hz, 45 mV and 7 mV). Copper and lead analyzes were performed simultaneously using 0.1 M hydrochloric acid as the electrolyte, While the zinc was analyzed separately using the 0.1 M acetate buffer (pH = 4.6) as the electrolyte. The microwave oven was the method chosen for digestion of all samples of facial cosmetics, where recoveries varied from 83-108%, 67-76% and 75-103% respectively for copper, lead and zinc. Limits of detection of the method for copper, lead and zinc varied from 0,05-0,36 μg g -1, and the limits of quantification of 0,36-1,16 μg g -1. Nine samples were analyzed, with concentrations of Cu, Pb and Zn varying respectively in 14-26.68 μg g-1; 1.319.74 μg g-1 and 7.1-42064 μg g -1. For the validation of the results obtained electrochemically, an F AAS (Cu and Zn) and GF AAS (Pb) were used. From statistical tests it was verified that there was no evidence of significant differences between the electrochemically developed method and F AAS, GF AAS with 95% confidence. The concentration levels found for metals are below the level established by the European company and do not pose a risk to human health as regards the metals analyzed.
25

Novos materiais para aplicações analíticas nas determinações de compostos orgânicos de interesse farmacêutico e ambiental / New materials for analytical application in organic compound determination for pharmaceutical and environmental interests

Felix, Fabiana da Silva 19 June 2009 (has links)
Sensores de filme de carbono, construídos a partir de resistores com 2 Ω de resistência nominal, foram utilizados para aplicações em áreas de interesse ambiental e farmacêutico sem a modificação prévia de suas superfícies. Através de um tratamento eletroquímico em meio ácido, é possível obter uma faixa de potencial (para ambos os limites anódico e catódico) maior comparado aos eletrodos de carbono convencionalmente utilizados. Devido ao fato dos sensores serem confeccionados em escala industrial na Alemanha, seu custo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Além disso, são caracterizados por uma grande versatilidade, reprodutibilidade e estabilidade. Para comprovar a viabilidade dos eletrodos de filme de carbono como transdutores voltamétricos, amostras de paraquat foram analisadas em águas de rio e potável. A associação com a voltametria de onda quadrada possibilitou obter um limite de detecção inferior ao limite máximo estabelecido para o herbicida em água potável. Estudos por voltametria cíclica mostraram dois picos para a redução do paraquat, similares aos descritos na literatura. Os sensores de filme de carbono também foram adaptados ao sistema de análise por injeção em fluxo para a determinação amperométrica de paracetamol e de ambroxol em formulações farmacêuticas. Em ambos os estudos, foi possível obter ampla faixa linear de concentração, baixos limites de detecção e sensibilidade elevada. Estudos de repetibilidade com os dois analitos apresentaram desvios padrões relativos de até 3%, comprovando a ausência de efeito de memória. Os resultados obtidos durante as análises em fluxo com os novos sensores amperométricos concordaram com as metodologias descritas nas farmacopéias. Ao longo dos quatro anos de doutoramento também foram desenvolvidos outros estudos, os quais estão descritos nos apêndices desta tese. / Carbon film sensors, built from resistors of 2 Ω nominal resistance, were employed for application in the environment and pharmaceutical fields without previous modification of the electrode surface. When these sensors are electrochemically treated they obtain a wider potential window (both anodic and cathodic regions) than many other forms of carbon. Due to the fact that sensors are produced on industrial scale in Germany, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. Moreover, they have great versatibility, reproducibility and stability. To prove the suitability of the carbon film electrodes as voltammetric sensors paraquat samples were analysed in river and drinking water. The association with the square wave voltammetry led to a detection limit below the allowed upper limit for herbicide analysis in drinking water. Previous results with cyclic voltammetry showed two peaks for paraquat reduction, in agreement with the literature data. The carbon film sensors were also adapted to the flow injection analysis system for amperometric determination of acetaminophen and ambroxol in pharmaceutical formulations. It was possible to obtain a wide linear working range, low detection limit and high sensitivity for both analytes. During the repeatabilty studies, acetaminophen and ambroxol showed relative standard desviations lower than 3% without any memory effect. The results obtained with a new amperometric sensor associated to FIA were in good agreement with those recommended by pharmacopoeias. In the appendices of this thesis are described other studies which have been developed for four years of PhD.
26

DESENVOLVIMENTO DE MÉTODOS VOLTAMÉTRICOS UTILIZANDO PLANEJAMENTO FATORIAL PARA DETERMINAÇÕES SIMULTÂNEAS DE ASSOCIAÇÕES FARMACÊUTICAS E COSMÉTICAS

Calaça, Giselle Nathaly 23 March 2015 (has links)
Made available in DSpace on 2017-07-20T12:40:14Z (GMT). No. of bitstreams: 1 Giselle Nathaly Calaca.pdf: 4129912 bytes, checksum: 17ad0dde0faa7762fe24c34e6ffcd471 (MD5) Previous issue date: 2015-03-23 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The development and validation of analytical methods for quantification of two associations, antibiotics: sulfamethoxazole (SMX) and trimethoprim (TMP); and depigmenting agents: kojic acid (AK) and hydroquinone (HQ), using unmodified glassy carbon electrode (ECV) and square wave voltammetry (SWV) are described. For the first association, two well defined irreversible oxidation peaks were obtained at 0.96V (SMX) and 1.12V (TMP) in Britton–Robinson buffer (pH 6.0), characterized by diffusion and adsorptive processes, respectively. SWV parameters were optimized by means of 23 Full Factorial Design, and the best analytical signal, in terms of sensitivity and selectivity is obtained at a=30 mV, f=100 s-1 and ΔES=5mV. Under optimized conditions, SWV measurements showed excellent linear response, from 5.5x10-5 to 3.95x10-4 mol L-1 (R=0.9971) and 1.05x10-5 to 1.04x10-4 mol L-1 (R=0.9974) for SMX and TMP, respectively. The detection and quantification limits were found to be 8.52x10-6 mol L-1 and 2.84x10-5 mol L-1 for SMX; and 9.31x10-7 mol L-1 and 3.10x10-6 mol L-1 for TMP, respectively. The proposed method was successfully applied to the simultaneous determination of these antibiotics in commercial pharmaceutical formulations (tablets, oral suspension and injection), without any sample pretreatment. The obtained results are in good agreement with that obtained by the standard HPLC method at a 95% confidence level. For the second association, the redox peak potentials were completely separated in Mcllvaine buffer solution (pH 8.0), KA exhibits a well-defined irreversible oxidation peak at 0.72V and HQ a quasi-reversible redox peak at 0.08 V and -0.02 V, characterized by adsorptive and diffusional processes, respectively. Under SWV parameters optimized (a= 40 mV, f=40 s-1 and ΔES=1mV) by 23 Full Factorial Design, the calibration curves were obtained in the concentration ranges of 3.5×10-5 to 2.5×10-4 mol L-1 (R= 0.9996) for kojic acid and 1.5×10-5 to 1.6×10-4 mol L-1 (R= 0.9994) for hydroquinone. The detection and quantification limits were found to be 7.84x10-6 mol L-1 and 2.61x10-5 mol L-1 for KA; and 3.71x10-6 mol L-1 and 1.24x10-5 mol L-1 for HQ, respectively. The novel electroanalytical method was validated in terms of specificity, linearity, range, accuracy and precision (repeatability and intermediate precision) and successfully applied to the direct simultaneous determination of these bleaching agents in real samples. / O trabalho descreve o desenvolvimento e a validação de métodos analíticos para quantificação de duas associações, os antibióticos: sulfametoxazol (SMX) e trimetoprima (TMP); e os agentes despigmentantes: ácido kójico (AK) e hidroquinona (HQ), empregando-se eletrodo de carbono vítreo (ECV) não modificado e voltametria de onda quadrada (VOQ). Para a primeira associação, dois picos de oxidação irreversíveis em 0,96V (SMX) e 1,12V (TMP) foram observados em tampão Britton–Robinson (pH 6,0), caracterizados por processos difusional e adsortivo, respectivamente. Os parâmetros instrumentais da VOQ foram otimizados por meio de um planejamento fatorial completo 23, sendo a melhor resposta em termos de sensibilidade e seletividade obtida em a=30 mV, f=100 s-1 e ΔES=5mV. Nas condições otimizadas, foram construídas curvas analíticas nos intervalos de concentração de 5,5x10-5 a 3,95x10-4 mol L-1 (R=0,9971) para SMX e 1,05x10-5 a 1,04x10-4 mol L-1 (R=0,9974) para TMP. Os valores de limites de detecção (LD) e de quantificação (LQ) calculados foram: 8,52x10-6 mol L-1 e 2,84x10-5 mol L-1 para SMX e 9,31x10-7 mol L-1 e 3,10x10-6 mol L-1 para TMP, respectivamente. O método proposto foi aplicado para determinação simultânea dos fármacos em diferentes amostras farmacêuticas (comprimidos, injeção e suspensão oral) sem a necessidade de nenhum tipo de pré-tratamento da amostra. Os resultados obtidos através do método voltamétrico foram comparados aos obtidos pelo método farmacopeico (HPLC) e comprovou-se que não há diferença significativa em um nível de confiança de 95%. Para a segunda associação, nos voltamogramas cíclicos em tampão Mcllvaine (pH=8,0) um pico de oxidação irreversível em +0,7V foi observado para o AK, enquanto que para HQ foi observado um processo quase-reversível, com picos de oxidação em 0,08V e redução em -0,02V, caracterizados por processos adsortivo e difusional, respectivamente. Utilizando-se os parâmetros da VOQ otimizados (a= 40 mV, f= 40 s-1 e ΔES= 1mV), através de um planejamento fatorial completo 23, as curvas de calibração foram obtidas nas faixas de concentração de 3,5×10-5 a 2,5×10-4 mol L-1 (R= 0,9996) para AK e 1,5×10-5 a 1,6×10-4 mol L-1 (R= 0,9994) para HQ. Os limites de detecção e quantificação foram: 7,84x10-6 mol L-1 e 2,61x10-5 mol L-1 para AK; e 3,71x10-6 mol L-1 e 1,24x10-5 mol L-1 para HQ, respectivamente. O método voltamétrico desenvolvido foi validado em termos de especificidade, linearidade, faixa de concentração, exatidão e precisão (repetibilidade e precisão intermediária) e aplicado na determinação simultânea dos agentes despigmentantes em amostras de clareadores.
27

Desenvolvimento de metodologias eletroanalíticas para determinação de pesticidas em óleo essencial de laranja / Development of electroanalytical methodologies for pesticides determination in orange essential oil

Andrade, Fernanda Ramos de 01 August 2014 (has links)
A citricultura, introduzida no Brasil na época da colonização e explorada comercialmente a partir dos anos 30 do século passado, é um setor de grande importância para o agronegócio brasileiro. Atualmente, o Brasil detém 50% da produção mundial de laranja e cerca de 85% de toda exportação mundial, representando uma captação de divisas de cerca de 2,5 bilhões de dólares por ano, devido principalmente à exportação do suco de laranja. Apesar do suco ser o principal produto de exportação da citricultura, vários subprodutos com valor comercial são obtidos durante seu processo de produção, tais como os óleos essenciais cítricos. Esses subprodutos localizam-se na casca da fruta e são obtidos durante o processo de extração do suco de laranja por prensagem a frio. Devido ao uso intensivo de pesticidas na citricultura e que muitas vezes se acumula na casca da fruta é comum à obtenção de óleos essenciais com resíduos de pesticidas, o que reduz seu preço de mercado internacional e limita sua inserção em mercados exigentes como o Europeu, Japonês e Americano, por exemplo. Este trabalho propõe o desenvolvimento de metodologias eletroanalíticas para a determinação de alguns pesticidas amplamente utilizados na citricultura brasileira e que têm sido encontrados nos óleos essenciais produzidos pelas indústrias de processamento. Inicialmente, foram realizados testes para avaliação da eletroatividade de três pesticidas (piridafention, cihexatina e bromopropilato) amplamente utilizados no Brasil, mas que são proibidos na maioria dos países importadores, sendo, portanto, de importância estratégica. Utilizando-se a técnica de voltametria cíclica verificou-se que o piridafention apresenta resposta sobre o eletrodo compósito de grafite-poliuretana (GPU), a cihexatina apresentou eletroatividade sobre o eletrodo de filme de bismuto e o bromopropilato não foi eletroativo nas superfícies eletródicas testadas. Varreduras realizadas com voltametria cíclica mostraram que o piridafention apresenta um pico de redução em -0,80 V (vs. EECS) sobre eletrodo compósito de GPU em meio ácido (tampão Britton-Robinson 0,1 mol L-1) com características de processo irreversível. Em seguida, desenvolveu-se uma metodologia eletroanalítica, utilizando a técnica de voltametria de onda quadrada (SWV), com a otimização do pH da solução (1,0) e demais parâmetros da SWV como a frequência (80 s-1), amplitude do pulso (50 mV) e incremento de varredura (ΔEi = 5 mV). Curvas analíticas foram obtidas no intervalo de 1,46 a 17,1 µmol L-1, apresentando boa linearidade, com coeficiente de determinação (r2) de 0,998. Os limites de detecção (LD) e de quantificação (LQ) obtidos foram de 0,27 µmol L-1 e 0,92 µmol L-1, respectivamente. A precisão da metodologia desenvolvida foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 98%. A metodologia eletroanalítica desenvolvida para determinação do piridafention foi aplicada em amostras de óleo essencial de laranja, contaminadas com três níveis de concentração 1,5, 2,9 e 5,9 µmol L-1. Foram avaliados quatro procedimentos de extração líquido-líquido, utilizando água Milli-Q como extrator: i) agitação manual da mistura (10 mL de óleo e 10 mL de água) por 4 minutos com repetição do procedimento por 3 vezes; ii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura ambiente; iii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura de 45°C; iv) agitação da mistura em mesa orbital com tempo de agitação variando de 5 até 180 minutos. Os melhores resultados foram obtidos com o procedimento utilizando a agitação por mesa orbital (iv), sendo recomendado, portanto, para extração do piridafention em amostras de óleo essencial de laranja. No caso da cihexatina, os testes realizados visando à determinação de uma metodologia eletroanalítica mostraram uma baixa reprodutibilidade do eletrodo filme de bismuto inviabilizando a sua aplicação na eletroanálise da cihexatina. Entretanto, devido à importância da cihexatina e do bromopropilato recomenda-se a realização de mais estudos eletroquímicos com o objetivo de se estabelecer novos métodos de análise. / The citrus production introduced in Brazil during the colonization period and commercially exploited since 1930, is very important for the Brazilian agribusiness. Currently, Brazil is responsible for 50% of the total world citrus production and for about 85% of the citrus world exportation trade, representing an income of about 2.5 billion dollars for the country yearly. The orange juice is the major product of the citrus industry, but other commercially valuable byproducts can be obtained during the manufacturing process, such as the citrus essential oils. These byproduct, located at the orange fruit exocarp, are extracted during the juice production process by cold pressing. Due to the use of pesticides in the citrus production, these agrochemicals can be occasionally presented in extracted essential oil products as unwished residues, which significantly reduce their values in the international market and restrict their insertion in exigent markets as the European, Japanese and North American, for instance. This study aim to develop electroanalytical methodologies for the determination of some pesticides widely employed in the Brazilian citrus production and that has been found in the essential oils produced by the processing industries. Preliminar tests were conducted to evaluate the electroactivity of three pesticides (pyridaphention, cyhexatin and bromopropylate) widely applied in Brazil, but not regulated for use in most of the importing countries. Using the cyclic voltammetry technique, these experiments showed that pyridaphenthion presented a good electrochemical response on the graphite-polyurethane composite electrode (GPU), cyhexatin showed electroactivity on thin bismuth film electrode and bromopropylate was not electroactive on the tested electodes. Studies conducted using cyclic voltammetry showed that pyridaphenthion presents a reduction peak in -0.8 V (vs. ESCE) on GPU in acidic medium (Britton - Robinson buffer 0.1 mol L- 1(BR)) with features of an irreversible process. The electroanalytical methodology for pyridaphenthion analysis was developed using square wave voltammetry (SWV) with optimization of pH (1.0) and the SWV scanning parameters, as pulse frequency (80 s-1), amplitude (50 mV), and increment (ΔEi = 5 mV). An analytical curve was obtained for concentrations ranging from 1.46 a 17.1 µmol L-1, showing good linearity expressed in the determination coefficient (r2) of 0.998. The detection limit (LOD) and quantification limit (LOQ) obtained were 0.27 µmol L-1 and 0.92 µmol L-1, respectively. The precision was evaluated by means its repeatability and reproductibility, while accuracy was assessed by means relative error. Recovery experiments conducted using the standard addition method provided a concentration recovering level of 98%. The electroanalytical methodology developed for pyridaphenthion was applied in citrus essential oil samples spiked with three concentration levels 1.5, 2.9 and 5.9 µmol L-1. Four liquid-liquid extraction procedures were evaluated using only Milli-Q purified water as extracting agent: i) manual stirring of the mixture (10 mL of essential oil and 10 mL of water) during 4 minutes, repeating the procedure three times; ii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at room temperature; iii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at 45o C; iv) orbital shaking of the mixture (5 mL of essential oil and 50 mL of water) for different period of times varying from 5 to 180 minutes. The best results were obtained with the procedure using the orbital shaking table (iv), which is, therefore, recommended for extraction of pyridaphention residues in citrus essential oils samples. For the cyhexatin, studies carried out aiming to determine an electroanalytical methodology, showed low reproducibility of the bismuth film, preventing its application in the electroanalysis of cyhexatin. However, due to the importance of these pesticides in citrus essential oils production it is recommended additional studies regarding the electrochemistry and electroanalysis of these chemicals.
28

Desenvolvimento e valida??o de metodologias eletroanal?ticas para determina??o de f?rmacos antituberculose

Ferraz, Bruno Regis Lyrio 11 March 2016 (has links)
Submitted by M?rden L?les (marden.inacio@ufvjm.edu.br) on 2016-07-14T23:55:27Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Bruno Regis Lyrio Ferraz.PDF: 3015137 bytes, checksum: d479e9335e2f200939b52075f9b84382 (MD5) / Rejected by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br), reason: Inserir ano em nota de tese. Inserir t?tulo em ingl?s Inserir tipo de trabalho on 2016-07-18T15:05:26Z (GMT) / Submitted by M?rden L?les (marden.inacio@ufvjm.edu.br) on 2016-07-19T20:24:24Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Bruno Regis Lyrio Ferraz.PDF: 3015137 bytes, checksum: d479e9335e2f200939b52075f9b84382 (MD5) / Rejected by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br), reason: renomear on 2016-07-21T16:57:12Z (GMT) / Submitted by M?rden L?les (marden.inacio@ufvjm.edu.br) on 2016-07-21T17:33:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Bruno_Regis_Lyrio_Ferraz.PDF: 3015137 bytes, checksum: d479e9335e2f200939b52075f9b84382 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-07-22T15:28:18Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Bruno_Regis_Lyrio_Ferraz.PDF: 3015137 bytes, checksum: d479e9335e2f200939b52075f9b84382 (MD5) / Made available in DSpace on 2016-07-22T15:28:18Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Bruno_Regis_Lyrio_Ferraz.PDF: 3015137 bytes, checksum: d479e9335e2f200939b52075f9b84382 (MD5) Previous issue date: 2016 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Funda??o de Amparo a Pesquisa do Estado de Minas Gerais (FAPEMIG) / RESUMO Etionamida e pirazinamida s?o antibi?ticos ?teis no tratamento da tuberculose multirresistente. O presente trabalho descreve o desenvolvimento e valida??o de metodologias eletroanal?ticas para determina??o de etionamida e pirazinamida em formula??es farmac?uticas e em urina humana empregando um eletrodo de diamante dopado com boro e um eletrodo de carbono v?treo modificado comum filme de poli glicina. Durante o desenvolvimento de ambas as metodologias, a voltametria c?clica foi empregada para verificar a influ?ncia do pH, da velocidade de varredura e do eletr?lito suporte no comportamento eletroqu?mico de ambos os analitos, bem como foram calculados os n?meros de pr?tons e el?trons envolvidos em cada uma das rea??es eletroqu?micas. A voltametria de onda quadrada com os par?metros otimizados foi utilizada para construir curvas anal?ticas para a ETO e PZA. Para a ETO foi obtido um intervalo linear de 1,0 a 80,0 ?mol L?1, com LOD e LOQ iguais a 0,294 e 0,980 ?mol L?1, respectivamente. Para a PZA foi obtido um intervalo linear de 0,47 a 6,16 ?mol L?1, com LOD e LOQ iguais a 0,035 e 0,12 ?mol L?1, respectivamente. A precis?o foi avaliada pelo registro de voltamogramas no mesmo dia e em dias diferentes, obtendo-se desvios padr?es relativos, inferiores a 5,0% em ambos os m?todos. Os resultados dos estudos de interferentes mostraram que nenhuma das subst?ncias testadas interferiu de maneira significativa na determina??o de ambos os f?rmacos. Os m?todos desenvolvidos foram comparados estatisticamente com os protocolos oficiais da farmacopeia atrav?s do teste-t e do teste-F, e os resultados mostraram que os valores de t e F calculados foram menores do que os valores de t e F cr?ticos, indicando que n?o houve diferen?a estat?stica entre as m?dias. A exatid?o de ambos os m?todos foi avaliada tamb?m por estudos de adi??o e recupera??o, obtendo-se como resultados percentuais de recupera??o pr?ximos a 100% para ambos os m?todos. A valida??o das metodologias desenvolvidas foi realizada pela avalia??o dos par?metros anal?ticos como sensibilidade, seletividade, limite de detec??o, limite de quantifica??o, faixa linear, exatid?o e precis?o e os resultados obtidos foram satisfat?rios. Portanto, os m?todos desenvolvidos podem ser aplicados com sucesso na determina??o dos f?rmacos ETO e PZA em medicamentos e urina humana. / Disserta??o (Mestrado) ? Programa de P?s-gradua??o em Ci?ncias Farmac?uticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2016. / ABSTRACT Ethionamide and pyrazinamide antibiotics are useful in the treatment of multidrugresistant tuberculosis. This work describes the development and validation of electroanalytical methodologies for determination of ethionamide and pyrazinamide in pharmaceutical formulation and human urine using boron-doped diamond electrode and poly glycine modified glassy carbon electrode, respectively. During the development of both methodologies, cyclic voltammetry was used to investigate the influence of pH, scan rate and the supporting electrolyte on the electrochemical behavior of both analytes, as well as the numbers of protons and electrons involved in each of the electrochemical reactions were calculated. Square wave voltammetry with optimized parameters were used to construct standard curves for ETO and PZA. For ETO a linear range from 1.0 to 80.0 ?mol L?1 was obtained with LOD and LOQ equal to 0.294 and 0.980 ?mol L?1, respectively. For PZA a linear range from 0.47 to 6.16 ?mol L?1was obtained with LOD and LOQ equal to 0.035 and 0.12 ?mol L?1, respectively. The precision was evaluated by voltammograms record on the same day and on different days, obtaining relative standard deviation less than 5.0% in both methods. The results of interfering studies showed that none of the tested substance interferes significantly in the determination of both drugs. The developed methods were statistically compared with the pharmacopoeia official protocols through the t-test and F-test, and the results showed that the calculated t and F values were lower than the critical t and F values indicating that there was no statistical difference between the averages. The accuracy of both methods was also evaluated by addition and recovery studies, obtaining results as percentage recovery close to 100% for both methods. The validation of the developed methodologies was carried out by the evaluation of analytical parameters such as sensitivity, selectivity, detection limit, quantification limit, linear range, accuracy and precision and the obtained results were satisfactory. Therefore, the developed methods can be applied successfully in the determination of ETO and PZA drugs in pharmaceuticals and human urine.
29

Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável

Lúcio, Maria Mônica Lacerda Martins 26 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-11T12:53:38Z No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) / Made available in DSpace on 2016-05-11T12:53:38Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) Previous issue date: 2015-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Triclocarban (TCC) is a bactericide and fungicide widely used in personal care products, while carbendazim (MBC) is a fungicide widely used in cereal crops and a variety of fruits and vegetables, both are considered environmental contaminants. In this paper, propose the study of oxidation and determination of TCC using glassy carbon electrode (ECV) and the use of a carbon paste electrode modified with carbon nanotubes functionalized multi walled (EPC-NTCPMF) to determine MBC. Electrochemical detection of TCC and MBC was studied using different voltammetric techniques on a wide range of pH and the determination was performed on samples of soaps, only the TCC and drinking water at low concentrations, for both contaminants. For TCC, various oxidation processes were observed, however the peak P1 had greater sensitivity and selectivity in acetate buffer, pH 5.4 and was therefore used for the development of voltammetric methods, direct VOQ and adsorptive stripping voltammetry. For adsorptive stripping voltammetry, the linear response range was from 1.8 to 21 × 10-9 mol L-1 with a detection limit (LD) of 3.2 × 10-10 mol L-1, 1,000 times smaller than the LD obtained by direct VOQ. The method of adsorptive stripping voltammetry showed satisfactory levels of repeatability, 4.1% and reproducibility, 5.4% and was applied to determine TCC in soaps samples and an average recovery of 95.3% and drinking water with an average recovery apparent 95.4%. The MBC peaked main oxidation, almost reversible; the better sensitivity was achieved in H2SO4, pH 1.0 on the EPC-NTCPMF using VOQ. The linear response range is between 3 and 150 × 10-10 mol L-1 to LD 1.1 × 10-11 mol L-1. The method developed showed acceptable levels of repeatability, 4.6% and reproducibility, 6.2% and was applied for MBC determination in drinking water samples obtained average apparent recovery of 95.6%. The results obtained in the development of methods for determination of TCC and MBC showed excellent applicability for the studied samples, in addition to having advantages such as low cost instrumentation, analytical fast response, high sensitivity and selectivity. / Triclocarban (TCC) é um bactericida e fungicida amplamente utilizado em produtos de higiene pessoal, enquanto que o carbendazim (MBC) é um fungicida muito utilizado em culturas de cereais e numa grande variedade de frutas e vegetais, e ambos são considerados contaminantes ambientais. Nesse trabalho, propõe-se o estudo da oxidação e determinação do TCC utilizando eletrodo de carbono vítreo (ECV) e o uso de um eletrodo de pasta de carbono modificado com nanotubos de carbono de múltiplas paredes funcionalizado (EPC-NTCPMF) para determinação de MBC. A detecção eletroquímica de TCC e MBC foi estudada utilizando diferentes técnicas voltamétricas sobre uma ampla faixa de pH e a determinação foi realizada em amostras de sabonetes para TCC e em água potável em baixas concentrações para os dois contaminantes. Para TCC, foram observados seis processos de oxidação, entretanto, o processo correspondente ao pico P1 apresentou maior sensibilidade e seletividade em tampão acetato pH 5,4, portanto, foi utilizado para o desenvolvimento das metodologias voltamétricas, VOQ direta e VOQ com redissolução adsortiva. Para a VOQ com redissolução adsortiva, a faixa de resposta linear foi de 1,8 a 21 × 10-9 mol L-1 com limite de detecção (LD) de 3,2 × 10-10 mol L-1, 1.000 vezes menor do que o LD obtido por VOQ direta. O método de redissolução adsortiva apresentou níveis satisfatórios de repetibilidade, 4,1% e reprodutibilidade, 5,4% e foi aplicado para determinação de TCC em amostras de sabonetes, obtendo uma recuperação média de 95,3% e água potável com uma média de recuperação aparente de 95,4%. O MBC apresentou um pico de oxidação principal, quase reversível e a maior sensibilidade foi alcançada em H2SO4, pH 1,0, sobre o EPC-NTCPMF, utilizando VOQ. A faixa de resposta linear está entre 3 e 150 × 10-10 mol L-1 com LD de 1,1 × 10-11 mol L-1. O método desenvolvido apresentou níveis satisfatórios de repetibilidade, 4,6% e reprodutibilidade, 6,2% e foi aplicado para determinação de MBC em amostras de água potável, obtendo-se valor médio de recuperação aparente de 95,6%. Os resultados obtidos no desenvolvimento dos métodos para determinação de TCC e MBC demonstraram excelente aplicabilidade para as amostras estudadas, além de apresentarem vantagens como instrumentação de baixo custo, rápida resposta analítica, elevada sensibilidade e seletividade.
30

Novos materiais para aplicações analíticas nas determinações de compostos orgânicos de interesse farmacêutico e ambiental / New materials for analytical application in organic compound determination for pharmaceutical and environmental interests

Fabiana da Silva Felix 19 June 2009 (has links)
Sensores de filme de carbono, construídos a partir de resistores com 2 Ω de resistência nominal, foram utilizados para aplicações em áreas de interesse ambiental e farmacêutico sem a modificação prévia de suas superfícies. Através de um tratamento eletroquímico em meio ácido, é possível obter uma faixa de potencial (para ambos os limites anódico e catódico) maior comparado aos eletrodos de carbono convencionalmente utilizados. Devido ao fato dos sensores serem confeccionados em escala industrial na Alemanha, seu custo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Além disso, são caracterizados por uma grande versatilidade, reprodutibilidade e estabilidade. Para comprovar a viabilidade dos eletrodos de filme de carbono como transdutores voltamétricos, amostras de paraquat foram analisadas em águas de rio e potável. A associação com a voltametria de onda quadrada possibilitou obter um limite de detecção inferior ao limite máximo estabelecido para o herbicida em água potável. Estudos por voltametria cíclica mostraram dois picos para a redução do paraquat, similares aos descritos na literatura. Os sensores de filme de carbono também foram adaptados ao sistema de análise por injeção em fluxo para a determinação amperométrica de paracetamol e de ambroxol em formulações farmacêuticas. Em ambos os estudos, foi possível obter ampla faixa linear de concentração, baixos limites de detecção e sensibilidade elevada. Estudos de repetibilidade com os dois analitos apresentaram desvios padrões relativos de até 3%, comprovando a ausência de efeito de memória. Os resultados obtidos durante as análises em fluxo com os novos sensores amperométricos concordaram com as metodologias descritas nas farmacopéias. Ao longo dos quatro anos de doutoramento também foram desenvolvidos outros estudos, os quais estão descritos nos apêndices desta tese. / Carbon film sensors, built from resistors of 2 Ω nominal resistance, were employed for application in the environment and pharmaceutical fields without previous modification of the electrode surface. When these sensors are electrochemically treated they obtain a wider potential window (both anodic and cathodic regions) than many other forms of carbon. Due to the fact that sensors are produced on industrial scale in Germany, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. Moreover, they have great versatibility, reproducibility and stability. To prove the suitability of the carbon film electrodes as voltammetric sensors paraquat samples were analysed in river and drinking water. The association with the square wave voltammetry led to a detection limit below the allowed upper limit for herbicide analysis in drinking water. Previous results with cyclic voltammetry showed two peaks for paraquat reduction, in agreement with the literature data. The carbon film sensors were also adapted to the flow injection analysis system for amperometric determination of acetaminophen and ambroxol in pharmaceutical formulations. It was possible to obtain a wide linear working range, low detection limit and high sensitivity for both analytes. During the repeatabilty studies, acetaminophen and ambroxol showed relative standard desviations lower than 3% without any memory effect. The results obtained with a new amperometric sensor associated to FIA were in good agreement with those recommended by pharmacopoeias. In the appendices of this thesis are described other studies which have been developed for four years of PhD.

Page generated in 0.0651 seconds