• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 12
  • 8
  • 4
  • 2
  • 1
  • Tagged with
  • 47
  • 47
  • 47
  • 13
  • 12
  • 10
  • 10
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

"Qualidade de vida e qualidade de vida no trabalho de profissionais de enfermagem atuantes em unidades do bloco cirúrgico" / Quality of life and work quality of life among nursing professionals active in surgical settings.

Denise Rodrigues Costa Schmidt 21 December 2004 (has links)
A hipótese principal testada nesse estudo foi que a qualidade de vida do indivíduo está diretamente correlacionada com a qualidade de vida no trabalho, ou seja, quanto maior a qualidade de vida no trabalho, maior a qualidade de vida. O objetivo geral foi avaliar e correlacionar as variáveis qualidade de vida e qualidade de vida no trabalho de profissionais de enfermagem atuantes em unidades do Bloco Cirúrgico de quatro hospitais da cidade de Londrina – PR. Trata-se de um estudo descritivo e correlacional, do tipo corte transversal do qual participaram 105 trabalhadores. A coleta de dados foi realizada com a utilização de três questionários: caracterização sociodemográfica, Escala Adaptada de Qualidade de Vida de Flanagan e o Índice de Satisfação Profissional de Stamps. Ambos os instrumentos foram usados nas versões adaptadas para o português e mostraram valores do alfa de Cronbach de 0,81 para as duas escalas, o que indica a confiabilidade das mesmas na população estudada. Dos participantes, a maioria era do sexo feminino (82,9%) e casado (62,9%). Quanto à caracterização profissional, 12 eram enfermeiros, um técnico, 73 auxiliares e 18 atendentes que atuavam em Centro Cirúrgico (55,2%), Central de Material e Esterilização (33,3%) ou em ambos locais (11,5%). O tempo médio de atuação nas instituições foi de 9,82 anos (intervalo de seis meses a 29 anos). Os resultados relacionados à qualidade de vida nos quais, em um intervalo possível de 16 a 112, quanto maior o valor, maior a satisfação com a vida, obtivemos uma mediana de 77 e média de 77,2+10,5. A média de todos os 16 itens foi de 4,83+0,65 (resultado avaliado entre nem insatisfeito/nem satisfeito e satisfeito). O item de menor satisfação foi atividades recreacionais e esportivas e o de maior satisfação relacionamento com amigos. No que se refere à qualidade de vida no trabalho, os valores obtidos variaram entre 114 a 227 (intervalo possível de 44 a 308), sendo que quanto maior o valor, maior a satisfação com o trabalho. A média obtida foi de 169,7+25,9 e a mediana de 170. O valor médio obtido para os 44 itens foi de 3,85, mostrando que os trabalhadores estavam entre insatisfeitos e nem satisfeitos/ nem insatisfeitos com os aspectos abordados pelo instrumento de qualidade de vida no trabalho. Entre os seis domínios avaliados pelo instrumento, obtivemos que a Remuneração foi considerada como fonte de menor satisfação entre os trabalhadores, enquanto o domínio Status profissional, o de maior satisfação. Para testar a correlação entre as variáveis QV e QVT usamos o teste não paramétrico de Spearman e obtivemos um valor de 0,17 (p=0,07). Assim, constatamos que não houve correlação entre as variáveis, o que não comprovou a nossa hipótese inicial. / The hypothesis tested in this study was that the quality of life of a person is directly correlated to the quality of life at work. Therefore, the better the quality of life at work, better will be the quality of life. The general aim was to evaluate and correlate the variables quality of life at work among nursing professionals working at the surgical unit of four hospitals located in the city of Londrina, state of Paraná. This is a descriptive and correlational study, of the cross sectional type, with a sample of 105 professionals. Data were collected through a questionnaire containing Flanagan’s Adapted Quality of Life Scale and Stamps’ Index of Work Satisfaction. Both instruments were used in their versions adapted to Portuguese and showed values of Cronback alpha of 0.81 for both scales, indicating their reliability in the population studied. Among the participants, the majority were women (82.9%) and married (62.9%). With respect to professional characterization, 12 were nurses, 1 technician, 73 auxiliaries and 18 aids who worked at the Surgical Unit (55.2%), Sterilization and Material Unit (33.3%) or both (11.5%). The average time of work at the institutions was of 9.82 years (interval between six months and 29 years). Considering the results related to the quality of life in which, in a possible interval of 16 to 112 years, greater the value, greater will be life satisfaction, the author found a median of 77 and average of 77.2+10.5. The average of all the 16 items was of 4.83+0.65 (results evaluated between neither satisfied nor dissatisfied and satisfied). The item with lower satisfaction level was related to recreational and sports activities and the one with higher satisfaction rate was relationship with friends. Regarding quality of life at work, values varied between 114 and 227 (possible range of 44 to 308), considering that greater the value, greater will be the work satisfaction. The average was of 169.7+25.9 and the median of 170. The average value obtained for the 44 items was of 3.85, showing that workers were dissatisfied and neither satisfied nor dissatisfied with the aspects mentioned in the instrument on quality of life at work. Among the six domain evaluated by the instrument, the author found that remuneration was considered the source of lower satisfaction among workers, while the domain professional status was the one with higher satisfaction level. In order to test the correlation between the two variables, the Spearman non parametric test was applied and the author found a value of 0.17 (p=0.07). Thus, there were no correlation among the variables and the initial hypothesis was not confirmed.
32

O acolhimento de usuários no centro cirúrgico e a humanização das práticas cotidianas do cuidado de enfermagem / The user embracement in general surgical ward and the humanization of the daily nursing care practice

Mariana Nepomuceno Giron 18 December 2013 (has links)
Falar da humanização é retomar a tradição do ocidente de pensar o lugar que o ser humano ocupa no mundo, nas inter-relações com seus semelhantes, na esfera social e também de saúde, em uma ética e solidariedade. Para uma prática de cuidados humanizada, o início destes cuidados deve ocorrer com o acolhimento do usuário em todos os setores, entre eles o Centro Cirúrgico. Este estudo tem como objetivo geral: compreender o processo de acolhimento no cotidiano da assistência de enfermagem no Centro Cirúrgico a partir da diretriz: acolhimento, ambiência e clínica ampliada da Política Nacional de Humanização. E como objetivos específicos: descrever o acolhimento do usuário durante as práticas cotidianas do cuidado de enfermagem no Centro Cirúrgico; analisar as experiências de acolhimento na perspectiva dos usuários no Centro Cirúrgico durante as práticas cotidianas do cuidado de enfermagem e identificar as estratégias utilizadas durante o cuidado de enfermagem no Centro Cirúrgico que concretizam a viabilização da diretriz: acolhimento, ambiência e clínica ampliada. Para dar conta do estudo selecionamos a abordagem etnometodológica, caráter exploratório. O cenário do estudo foi um hospital da rede estadual do Rio de Janeiro e os dados foram coletados por meio de entrevista semiestruturada realizada com 18 usuários em pós-operatório e observação participante no Centro Cirúrgico. Em seguida submetidos à análise de conteúdo de Bardin, emergindo três categorias: A recepção do usuário no Centro Cirúrgico; caracterização da realização do acolhimento na recepção do Centro Cirúrgico na perspectiva do usuário e estratégias de cuidado direcionadas para ambiência, acolhimento e clínica ampliada. Conclui-se que compreender o processo de acolhimento no cotidiano da assistência de enfermagem somente foi possível pelo compartilhamento de experiências de usuários que utilizaram os serviços da unidade. O cuidado de enfermagem neste ambiente foi identificado a partir de duas práxis: na recepção do paciente para cirurgia eletiva e diferentemente para cirurgia de emergência. O ambiente do Centro Cirúrgico gera no usuário uma gama de sentimentos e há um imaginário em torno do evento cirúrgico e deste espaço. No que se refere à diretriz, o cuidado de enfermagem neste setor atende parcialmente ao que esta estabelecido. Um caminho para a viabilização da PNH e da diretriz: acolhimento, ambiência e clínica ampliada é a educação continuada em serviço que deve não somente dispor da política em sua teoria, mas desenvolver métodos para que a torne concreta e palpável promovendo melhoria no cuidado de enfermagem. / To talk about humanization is to recapture the western tradition of thinking about the place where the human being occupies in the world, about the interrelationship between its fellow human beings, about the social as well as health care sphere, about ethics and solidarity. To a humanized care practice the beginning of this care must occur with the user embracement in all sectors, including the general surgical ward. The main goal of this study is: to comprehend the user embracement process in the everyday of the nurse assistance in the general surgical ward through the directive: user embracement, ambiance and extended general practice from the Política Nacional de Humanização (PNH). As the specific goals: to describe the user embracement during the daily nursing care practice in the general surgical ward; to analyze the user embracement experiences from the perspective from the users in the general surgical ward during the daily nursing care practice and to identify the strategies used during the nursing care in the general surgical ward that make the feasibility of the directive real: User Embracement, Ambiance and Extended General Practice. In order to carry the study through we chose the ethnomethodological approach with an exploratory research design. The study scenario is a Rio de Janeiro States hospital and the data were collected through semi-structured interviews with eighteen participants in post-operative care and participant observation in the general surgical ward. Afterwards they were submitted to the Bardins content analysis, from what three categories emerged: the reception of the user in the general surgical ward; characterization of the execution of the user embracement in the general surgical wards reception from the users perspective and strategies of care oriented towards the ambiance, user embracement and extended general practice. Final considerations: comprehending the user embracement process in the everyday of the nurse assistance was only possible through the sharing of the experiences of the users that used the services of the unit. Nursing care in this environment was identified through two praxes: in the reception of the user to elective surgery and differently to the emergency surgery. The ambiance of the general surgical ward creates in the user a range of feelings and there is an imaginary around the surgical event and this space. About the directive, the nursing care in this sector attends partially what is established. A way to the feasibility of the PNH and the directive: user embracement, ambiance and extended general practice is a lifelong learning in work that must not only employ the politics in its theory, but develop methods in order to make it real and tangible, promoting an improvement in the nursing care.
33

O acolhimento de usuários no centro cirúrgico e a humanização das práticas cotidianas do cuidado de enfermagem / The user embracement in general surgical ward and the humanization of the daily nursing care practice

Mariana Nepomuceno Giron 18 December 2013 (has links)
Falar da humanização é retomar a tradição do ocidente de pensar o lugar que o ser humano ocupa no mundo, nas inter-relações com seus semelhantes, na esfera social e também de saúde, em uma ética e solidariedade. Para uma prática de cuidados humanizada, o início destes cuidados deve ocorrer com o acolhimento do usuário em todos os setores, entre eles o Centro Cirúrgico. Este estudo tem como objetivo geral: compreender o processo de acolhimento no cotidiano da assistência de enfermagem no Centro Cirúrgico a partir da diretriz: acolhimento, ambiência e clínica ampliada da Política Nacional de Humanização. E como objetivos específicos: descrever o acolhimento do usuário durante as práticas cotidianas do cuidado de enfermagem no Centro Cirúrgico; analisar as experiências de acolhimento na perspectiva dos usuários no Centro Cirúrgico durante as práticas cotidianas do cuidado de enfermagem e identificar as estratégias utilizadas durante o cuidado de enfermagem no Centro Cirúrgico que concretizam a viabilização da diretriz: acolhimento, ambiência e clínica ampliada. Para dar conta do estudo selecionamos a abordagem etnometodológica, caráter exploratório. O cenário do estudo foi um hospital da rede estadual do Rio de Janeiro e os dados foram coletados por meio de entrevista semiestruturada realizada com 18 usuários em pós-operatório e observação participante no Centro Cirúrgico. Em seguida submetidos à análise de conteúdo de Bardin, emergindo três categorias: A recepção do usuário no Centro Cirúrgico; caracterização da realização do acolhimento na recepção do Centro Cirúrgico na perspectiva do usuário e estratégias de cuidado direcionadas para ambiência, acolhimento e clínica ampliada. Conclui-se que compreender o processo de acolhimento no cotidiano da assistência de enfermagem somente foi possível pelo compartilhamento de experiências de usuários que utilizaram os serviços da unidade. O cuidado de enfermagem neste ambiente foi identificado a partir de duas práxis: na recepção do paciente para cirurgia eletiva e diferentemente para cirurgia de emergência. O ambiente do Centro Cirúrgico gera no usuário uma gama de sentimentos e há um imaginário em torno do evento cirúrgico e deste espaço. No que se refere à diretriz, o cuidado de enfermagem neste setor atende parcialmente ao que esta estabelecido. Um caminho para a viabilização da PNH e da diretriz: acolhimento, ambiência e clínica ampliada é a educação continuada em serviço que deve não somente dispor da política em sua teoria, mas desenvolver métodos para que a torne concreta e palpável promovendo melhoria no cuidado de enfermagem. / To talk about humanization is to recapture the western tradition of thinking about the place where the human being occupies in the world, about the interrelationship between its fellow human beings, about the social as well as health care sphere, about ethics and solidarity. To a humanized care practice the beginning of this care must occur with the user embracement in all sectors, including the general surgical ward. The main goal of this study is: to comprehend the user embracement process in the everyday of the nurse assistance in the general surgical ward through the directive: user embracement, ambiance and extended general practice from the Política Nacional de Humanização (PNH). As the specific goals: to describe the user embracement during the daily nursing care practice in the general surgical ward; to analyze the user embracement experiences from the perspective from the users in the general surgical ward during the daily nursing care practice and to identify the strategies used during the nursing care in the general surgical ward that make the feasibility of the directive real: User Embracement, Ambiance and Extended General Practice. In order to carry the study through we chose the ethnomethodological approach with an exploratory research design. The study scenario is a Rio de Janeiro States hospital and the data were collected through semi-structured interviews with eighteen participants in post-operative care and participant observation in the general surgical ward. Afterwards they were submitted to the Bardins content analysis, from what three categories emerged: the reception of the user in the general surgical ward; characterization of the execution of the user embracement in the general surgical wards reception from the users perspective and strategies of care oriented towards the ambiance, user embracement and extended general practice. Final considerations: comprehending the user embracement process in the everyday of the nurse assistance was only possible through the sharing of the experiences of the users that used the services of the unit. Nursing care in this environment was identified through two praxes: in the reception of the user to elective surgery and differently to the emergency surgery. The ambiance of the general surgical ward creates in the user a range of feelings and there is an imaginary around the surgical event and this space. About the directive, the nursing care in this sector attends partially what is established. A way to the feasibility of the PNH and the directive: user embracement, ambiance and extended general practice is a lifelong learning in work that must not only employ the politics in its theory, but develop methods in order to make it real and tangible, promoting an improvement in the nursing care.
34

Operationssjuksköterskors erfarenheter av optimerad arbetsmodell i förhållande till vanlig elektiv arbetsmodell / Operation room nurses´experiences of optimized work model in relation to a conventional work model

Diaz Diaz, Natalia Carmen, Persson- Hjelm, Linda January 2011 (has links)
Bakgrund Inom hälso- och sjukvården eftersträvar verksamheterna att öka effektivitet och produktion. Studier visar att en av de verksamheter med störst möjlighet att öka sjukhusets produktion är operationsavdelningen. Utmaningen för operationsavdelningarna är att utföra fler ingrepp med befintliga resurser utan att personalen upplever ökad arbetsbelastning och stress. Med detta ändamål har de på det valda sjukhuset utarbetat en arbetsmodell. Syftet med denna studie är att undersöka operationssjuksköterskors erfarenheter av optimerad arbetsmodell i förhållande till vanlig elektiv arbetsmodell. Metod En kvalitativ studie genomfördes, ett bekvämlighetsurval användes och 18 operationssjuksköterskor från ett medelstort sjukhus i Mellansverige deltog i studien. Semistrukturerade intervjuer utfördes med hjälp av en intervjuguide, en kvalitativ manifest innehållsanalys utfördes. Resultatet Tre kategorier och sju subkategorier kom fram. Operationssjuksköterskorna ansåg att den optimerade arbetsmodellen gav många fördelar och få nackdelar för personalen, patienterna och verksamheten. Den ökade bemanningen samt standardiseringen av ingrepp, patienter, arbetsuppgifter, operationssalar och material var de faktorer som ledde till fördelarna i den optimerade arbetsmodellen. Hälften av operationssjuksköterskorna föredrog inte den ena arbetsmodellen framför den andra, antalet operationssjuksköterskor som hade en preferens var jämt fördelat mellan arbetsmodellerna. Slutsats En majoritet av operationssjuksköterskorna ansåg att den optimerade arbetsmodellen ledde till mindre stress och ökad patientsäkerhet samtidigt som ett fåtal upplevde ökad stress och sämre patientsäkerhet. / Background Healthcare organizations strive to increase their efficiency. Studies show that the operating room is one of the departments with the greatest possibility to increase a hospital's efficiency. Their challenge is to perform more surgeries using the existing resources without increasing personnel workload or causing stress. In order to achieve this a new work model has been established by the selected hospital. The aim of this study was to investigate the operation room nurses' experiences of this new work model in relation to a conventional work model. Method A qualitative study was performed, a convenience sample was used and 18 operation room nurses from a hospital in central Sweden took part in a survey. Semi-structured interviews were conducted with an interview guide, a manifest qualitative content analysis was performed. Results Three categories and seven subcategories emerged. The operating room nurses believed that the new work model lead to many advantages and few disadvantages for the staff, patients and the department as a whole. The operating room nurses believed that the increase in staffing combined with a standardization of operation procedures, patients, tasks, operation rooms and material were the main reasons to the advantages with the new work model. Half of the operating room nurses did not prefer one work model over the other, the amount of operating room nurses that did was equal between the two work models. Conclusion A majority of the operation room nurses believed that the new work model lead to a decline in stress and to higher patient safety, but a minority experienced more stress and lower patient safety.
35

Avaliação da esterilização a vapor do instrumental laparoscópico montado: abordagem laboratorial / Evaluation of steam sterilization of laparoscopic instruments assembled: laboratory approach

Camargo, Tamara Carolina de 29 July 2013 (has links)
Esta pesquisa avaliou a segurança microbiológica da esterilização a vapor do instrumental laparoscópico reutilizável montado. Foram selecionados dois tipos de instrumental laparoscópico reutilizável: trocarte e pinça de dissecção de 5mm. Considerando a eficácia da limpeza como pré-requisito essencial para o processo de esterilização, a PRIMEIRA ETAPA da pesquisa, avaliou 66 instrumentos laparoscópicos, sendo 33 pinças e 33trocartes, submetidos a diferentes métodos de limpeza, avaliando como desfecho os resíduos orgânicos de proteína, hemoglobina e carboidrato, após contaminação intencional com sangue de placenta humana. Os métodos de limpeza testados foram: (1) limpeza manual com enxágue em água potável; (2) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica sem enxágue; (3) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e (4) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e último enxágue em água destilada esterilizada. Os experimentos foram acompanhados pelos grupos controle Positivo (sem limpeza) e Negativo, composto por instrumental laparoscópico novos sem contaminação intencional, avaliados após os procedimentos de limpeza (1) e (4). Para avaliação dos resíduos orgânicos, utilizou-se o kit Quantipro BCA para dosagem de proteínas, TMB One para hemoglobina, fenol 5% e ácido sulfúrico para carboidrato, todos com leitura por espectrofotometria. O grupo controle Positivo evidenciou níveis médios de 332µg/cm2 proteína, 30µg/cm2 carboidrato e 417µg/cm2 hemoglobina. Conforme esperado, o método de limpeza (4) apresentou desempenho superior quando comparado com o método (1), reduzindo 92% a mais de µg/proteína/pinça e 60% a mais de µg/carboidrato/pinça e por trocarte, embora esta superioridade não tenha sido observada de uma forma uniforme em todo o experimento. No grupo controle Negativo, os níveis máximos de proteína detectados foram 1,70µg/cm2 e de carboidrato de 1,07µg/cm2, não sendo detectada hemoglobina. A SEGUNDA ETAPA, avaliou a esterilização do instrumental laparoscópico reutilizável montado com contaminação desafio de três vezes 106 esporos Geobacillus stearothermophillus ATCC 7953, impregnados em suporte de papel filtro extraídos do indicador biológico comercialmente disponível para monitoramento da autoclavação. Os experimentos microbiológicos foram acompanhados dos grupos controle Positivo (suporte do indicador biológico não submetido à esterilização) e controle Negativo (instrumentos laparoscópicos esterilizados desmontados com contaminação desafio). Como grupo Experimental, foram analisados 370 instrumentos laparoscópicos esterilizados montados, sendo 185 pinças e 185 trocartes. Três suportes de papel impregnados com os esporos foram introduzidos no interior de cada instrumento laparoscópico, precedidos de limpeza tipo (4), embalados em papel grau cirúrgico e submetidos à esterilização a vapor saturado sob pressão (134oC por 5 minutos). Com técnica asséptica, cada suporte de papel foi inoculado em meio de cultura de Tryptic Soy Broth (TSB), incubado a 56oC por 21 dias. Não sendo observado crescimento, as amostras foram submetidas a um choque térmico a 80oC, por 20 minutos, para estimular a germinação, com reincubação por mais 72 horas. Não houve crescimento microbiano algum nas amostras do grupo Experimental. Os resultados dos grupos controles foram satisfatórios. O controle Positivo confirmou o desafio imposto aos experimentos e o controle Negativo apresentou resultados esperados de ausência de crescimento. Este estudo forneceu fortes evidências científicas para os Centros de Material e Esterilização sustentarem a segurança microbiológica da prática de esterilização do instrumental laparoscópico montado / This study evaluated the microbiological safety of steam sterilization, the reusable laparoscopic instrument assembled. We selected two types of reusable laparoscopic instrument: trocar and dissecting forceps 5mm. Considering the efficacy of cleaning as an essential prerequisite for the sterilization process, the FIRST STEP evaluated 66 laparoscopic instruments, 33 trocars and 33 dissecting forceps, subjected to different cleaning methods evaluating outcome as organic waste protein, hemoglobin and carbohydrate after intentional contamination with blood from human placenta. Cleaning methods were tested: (1) manual cleaning rinse with potable water, (2) manual cleaning with rinsing in clean water, then cleaning ultrasonic without rinsing, (3) manual cleaning with rinsing in clean water, then cleaning ultrasonic rinse with potable water and (4) manual cleaning rinse with potable water, followed by ultrasonic cleaning with potable water rinse and final rinse in sterile distilled water. The experiments were accompanied by positive control groups (without cleaning) and negative, composed of laparoscopic instruments again without intentional contamination, assessed after the cleaning procedures (1) and (4). For evaluation of organic waste is used Quantipro BCA kit for the determination of protein, TMB One to hemoglobin, 5% phenol and sulfuric acid of carbohydrate with any read by spectrophotometry. The positive control group showed average levels of 332µg/cm2 protein, carbohydrate 30µg/cm2 and 417µg/cm2 hemoglobin. As expected, the cleaning method (4) superior performance when compared with the method (1), reducing 92% more µg/protein/forceps and more than 60% µg/carbohydrate/forceps and trocar, although this superiority has not been observed in a uniform manner throughout the experiment. In the negative control group maximum levels of protein detected were 1.70 µg/cm2 and 1.07 µg/cm2carbohydrate was not detected hemoglobin. The SECOND STEP evaluated the sterilization of reusable laparoscopic instruments assembled with contamination challenge 3 times 10 Geobacillusstearothermophillus spores ATCC 7953, impregnated strips filter paper extracted from commercially available biological indicator for monitoring steam sterilization. The experiments were accompanied microbiological positive control groups (biological indicator spore strips non-sterile) and negative (laparoscopic instruments sterilized contamination disassembled challenge). As experimental group were analyzed 370 laparoscopic instruments sterilized assembled, 185 dissecting forceps and 185 trocars. Three spore strips of paper impregnated were introduced in laparoscopic instrument within each preceded by cleaning type (4), packed in surgical paper and subjected to saturated steam sterilization under pressure (134oC for 5 minutes). With aseptic technique, each paper spore strip was inoculated into culture medium Tryptic Soy Broth (TSB) and incubated at 56oC for 21 days. No growth was observed, they were subjected to heat shock at 80oC for 20 minutes to stimulate germination, with more reincubation for 72 hours. There was no microbial growth in some samples of the experimental group. The results of the control groups were satisfactory. The Positive Control confirmed the challenge posed to experiments and the negative control presented results expected from the absence of growth. This study provides strong scientific evidence for the Centers for Material and Sterilization sustain the microbiological safety of the practice of sterilization of laparoscopic instruments assembled.
36

Eficácia da esterilização a vapor de instrumental laparoscópico montado versus desmontado: um estudo experimental / Effectiveness of the steam sterilization of assembled versus disassembled laparoscopic instruments: an experimental study

Camargo, Tamara Carolina de 30 March 2007 (has links)
A vídeo-laparoscopia é uma inovação tecnológica que trouxe indiscutíveis vantagens e também novos desafios, incluindo nestes, as diretrizes para o reprocessamento adequado dos instrumentais e seus acessórios. A autoclavação dos instrumentais laparoscópicos desmontados é mais segura, uma vez que a condução térmica é facilitada. No entanto, são artigos complexos, compostos por múltiplas peças e a sua remontagem no momento da cirurgia traz transtornos às equipes cirúrgicas, correndo o risco do não funcionamento ou de danos às peças pela montagem inadequada. Existe um arraigado conceito, entre os profissionais da saúde, que para o sucesso da esterilização ser alcançado, é necessário o contato direto do vapor com todas as superfícies dos materiais submetidos à autoclavação sem considerar também o raciocínio do calor latente. A destruição microbiana por meio da esterilização pelo vapor está essencialmente relacionada ao calor latente, gerado pela condensação deste em contato com a superfície fria do material, promovendo a termocoagulação das proteínas microbianas. É uma prática comum nos hospitais brasileiros a realização da autoclavação de instrumentos previamente montados, apesar de não haver comprovação científica consistente dessa prática. Isto posto, esta investigação teve o objetivo de avaliar a eficácia do processo de esterilização a vapor dos instrumentais laparoscópicos previamente montados, comparando os seus resultados com os desmontados, considerada neste estudo a melhor prática. Tratou-se de uma pesquisa experimental, laboratorial, com abordagem quantitativa. Foram selecionados dois modelos de maior complexidade dentre os instrumentos laparoscópicos para realização do estudo, sendo eles: trocarte com válvula tipo janela rosqueada de 5mm, composto por cinco peças desmontáveis e pinça para dissecção de 5mm, composta por quatro peças desmontáveis. Cada peça dos instrumentais foi considerada como uma unidade amostral na análise microbiológica. Este estudo teve então como Grupo Montado: instrumentais laparoscópicos montados; Grupo Desmontado: instrumentais laparoscópicos desmontados; Grupo Contagem Microbiana: instrumentais laparoscópicos submetidos aos procedimentos de contaminação desafio, encaminhados diretamente para o teste de contagem microbiana. O inóculo para a contaminação desafio constitui-se de suspensão do Geobacillus stearothermophilus, na forma esporulada, acrescido de sangue de carneiro desfibrinado esterilizado. Todos os instrumentais foram contaminados desmontados com o inóculo desafio. Os grupos Montado e Desmontado foram submetidos aos processos de limpeza manual, complementada pela limpeza automatizada em lavadora ultra-sônica com retrofluxo, enxágüe em água corrente e sob pressão. Por fim, foi realizado o enxágüe com água destilada esterilizada e secagem com ar comprimido medicinal. Na seqüência, foi realizado sorteio para composição dos Grupos Montado e Desmontado. Os instrumentais foram embalados individualmente em papel grau cirúrgico e submetidos à esterilização a vapor em autoclave com pré-vácuo. Após a esterilização, os instrumentais foram avaliados quanto à eficácia da esterilização, por meio dos resultados dos testes de cultura microbiológica, utilizando o método de inoculação direta. No Grupo Montado foram recuperados os microrganismos teste em três peças de uma mesma pinça (3/48) e em três peças de um mesmo trocarte (3/60), enquanto que no Grupo Desmontado o microrganismo teste não foi recuperado nas unidades amostrais estudadas. Nas condições desse experimento, os resultados obtidos refutaram a hipótese inicial da pesquisa quanto à segurança da autoclavação das pinças e dos trocartes utilizados em cirurgia laparoscópica previamente montados / The video laparoscopy is a technological innovation that brought unquestionable advantages and, also, new challenges, like: the policies for the adequate reprocessing of the instruments and its permanent accessories. The steam sterilization of disassembled laparoscopic instruments is much safer, once that the thermal conduction is facilitated. However, laparoscopic instruments are quite complex articles; they are composed by many parts and the reassemblage in site at the moment of the surgery brings many inconveniences to the surgical team, like the possibility of the instrument’s malfunctioning or non functioning at all, or even damages to the instruments due to inadequate assembling. There is a strong belief among the Healthcare Professionals about the necessity of the direct contact of the steam with all the surface of the materials submitted to the steam sterilization, which is correct, however it doesn´t consider the latent heat assumption as well. The destruction of the microbiological material throughout the steam sterilization is essentially related to the latent heat, created by the vapor condensation when in contact with the instrument´s cold surface, promoting the thermal-coagulation of microbiological proteins. Many hospitals use the steam sterilization of previously mounted instruments, although there´s not any consistent scientific evidence about the efficiency of this practice. Once stated this point, this investigation´s aim was: evaluate the effectiveness of the steam sterilization process of the previously mounted, permanent laparoscopic instruments. It was an experimental laboratorial research, using a quantitative approach. Two models of permanent laparoscopic instruments of major complexity were chosen for the experiments: a trocar with a 5mm screw window valve, composed by five dismountable parts and a 5mm dissection clamp, composed by four dismountable parts. Each part of the instruments was considered as a sample unit on the microbiological analysis. This study it had the Assembled Group was: mounted laparoscopic instruments; the Disassembled Group was: disassembled laparoscopic instruments; the Microbiological Counting Group was: laparoscopic instruments submitted to the - challenge contamination - procedures, being directed straight to the test of microbiological counting. The inoculants material used for the challenge contamination consisted on the suspension of the Geobacillus stearothermophilus, in its spore form, plus defibrinated and sterilized sheep blood. All the instruments were contaminated, disassembled with the challenge inoculants material. The Assembled and Disassembled groups were submitted to the manual cleaning processes, enhanced by the automatic cleaning in an ultrasonic washer with retro-flux, rinsed in running and under pressure water. At last, a rinsing with distilled water was performed; the drying process was made with medicinal compressed air. Then, a sorting was performed to decide about the composition of the Assembled and Disassembled groups. The instruments were individually packed in surgical paper and submitted to the steam sterilization in a pre-vacuum sterilizer machine. After the sterilization, the instruments were evaluated according to sterilization effectiveness throughout the microbiological culture test´s results, using the straight inoculation method. In the Assembled Group the microorganism´s tests were recovered in three parts of one same clamp (3/48) and in three parts of the same trocar (3/60), in the Disassembled Group the test microorganism wasn´t recovered in any of the sample unities. The results, under the conditions of the experiment, refuted the hypothesis of safety in the usage of the steam sterilization in previously mounted used clamps and trocar in laparoscopy
37

Avaliação da esterilização a vapor do instrumental laparoscópico montado: abordagem laboratorial / Evaluation of steam sterilization of laparoscopic instruments assembled: laboratory approach

Tamara Carolina de Camargo 29 July 2013 (has links)
Esta pesquisa avaliou a segurança microbiológica da esterilização a vapor do instrumental laparoscópico reutilizável montado. Foram selecionados dois tipos de instrumental laparoscópico reutilizável: trocarte e pinça de dissecção de 5mm. Considerando a eficácia da limpeza como pré-requisito essencial para o processo de esterilização, a PRIMEIRA ETAPA da pesquisa, avaliou 66 instrumentos laparoscópicos, sendo 33 pinças e 33trocartes, submetidos a diferentes métodos de limpeza, avaliando como desfecho os resíduos orgânicos de proteína, hemoglobina e carboidrato, após contaminação intencional com sangue de placenta humana. Os métodos de limpeza testados foram: (1) limpeza manual com enxágue em água potável; (2) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica sem enxágue; (3) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e (4) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e último enxágue em água destilada esterilizada. Os experimentos foram acompanhados pelos grupos controle Positivo (sem limpeza) e Negativo, composto por instrumental laparoscópico novos sem contaminação intencional, avaliados após os procedimentos de limpeza (1) e (4). Para avaliação dos resíduos orgânicos, utilizou-se o kit Quantipro BCA para dosagem de proteínas, TMB One para hemoglobina, fenol 5% e ácido sulfúrico para carboidrato, todos com leitura por espectrofotometria. O grupo controle Positivo evidenciou níveis médios de 332µg/cm2 proteína, 30µg/cm2 carboidrato e 417µg/cm2 hemoglobina. Conforme esperado, o método de limpeza (4) apresentou desempenho superior quando comparado com o método (1), reduzindo 92% a mais de µg/proteína/pinça e 60% a mais de µg/carboidrato/pinça e por trocarte, embora esta superioridade não tenha sido observada de uma forma uniforme em todo o experimento. No grupo controle Negativo, os níveis máximos de proteína detectados foram 1,70µg/cm2 e de carboidrato de 1,07µg/cm2, não sendo detectada hemoglobina. A SEGUNDA ETAPA, avaliou a esterilização do instrumental laparoscópico reutilizável montado com contaminação desafio de três vezes 106 esporos Geobacillus stearothermophillus ATCC 7953, impregnados em suporte de papel filtro extraídos do indicador biológico comercialmente disponível para monitoramento da autoclavação. Os experimentos microbiológicos foram acompanhados dos grupos controle Positivo (suporte do indicador biológico não submetido à esterilização) e controle Negativo (instrumentos laparoscópicos esterilizados desmontados com contaminação desafio). Como grupo Experimental, foram analisados 370 instrumentos laparoscópicos esterilizados montados, sendo 185 pinças e 185 trocartes. Três suportes de papel impregnados com os esporos foram introduzidos no interior de cada instrumento laparoscópico, precedidos de limpeza tipo (4), embalados em papel grau cirúrgico e submetidos à esterilização a vapor saturado sob pressão (134oC por 5 minutos). Com técnica asséptica, cada suporte de papel foi inoculado em meio de cultura de Tryptic Soy Broth (TSB), incubado a 56oC por 21 dias. Não sendo observado crescimento, as amostras foram submetidas a um choque térmico a 80oC, por 20 minutos, para estimular a germinação, com reincubação por mais 72 horas. Não houve crescimento microbiano algum nas amostras do grupo Experimental. Os resultados dos grupos controles foram satisfatórios. O controle Positivo confirmou o desafio imposto aos experimentos e o controle Negativo apresentou resultados esperados de ausência de crescimento. Este estudo forneceu fortes evidências científicas para os Centros de Material e Esterilização sustentarem a segurança microbiológica da prática de esterilização do instrumental laparoscópico montado / This study evaluated the microbiological safety of steam sterilization, the reusable laparoscopic instrument assembled. We selected two types of reusable laparoscopic instrument: trocar and dissecting forceps 5mm. Considering the efficacy of cleaning as an essential prerequisite for the sterilization process, the FIRST STEP evaluated 66 laparoscopic instruments, 33 trocars and 33 dissecting forceps, subjected to different cleaning methods evaluating outcome as organic waste protein, hemoglobin and carbohydrate after intentional contamination with blood from human placenta. Cleaning methods were tested: (1) manual cleaning rinse with potable water, (2) manual cleaning with rinsing in clean water, then cleaning ultrasonic without rinsing, (3) manual cleaning with rinsing in clean water, then cleaning ultrasonic rinse with potable water and (4) manual cleaning rinse with potable water, followed by ultrasonic cleaning with potable water rinse and final rinse in sterile distilled water. The experiments were accompanied by positive control groups (without cleaning) and negative, composed of laparoscopic instruments again without intentional contamination, assessed after the cleaning procedures (1) and (4). For evaluation of organic waste is used Quantipro BCA kit for the determination of protein, TMB One to hemoglobin, 5% phenol and sulfuric acid of carbohydrate with any read by spectrophotometry. The positive control group showed average levels of 332µg/cm2 protein, carbohydrate 30µg/cm2 and 417µg/cm2 hemoglobin. As expected, the cleaning method (4) superior performance when compared with the method (1), reducing 92% more µg/protein/forceps and more than 60% µg/carbohydrate/forceps and trocar, although this superiority has not been observed in a uniform manner throughout the experiment. In the negative control group maximum levels of protein detected were 1.70 µg/cm2 and 1.07 µg/cm2carbohydrate was not detected hemoglobin. The SECOND STEP evaluated the sterilization of reusable laparoscopic instruments assembled with contamination challenge 3 times 10 Geobacillusstearothermophillus spores ATCC 7953, impregnated strips filter paper extracted from commercially available biological indicator for monitoring steam sterilization. The experiments were accompanied microbiological positive control groups (biological indicator spore strips non-sterile) and negative (laparoscopic instruments sterilized contamination disassembled challenge). As experimental group were analyzed 370 laparoscopic instruments sterilized assembled, 185 dissecting forceps and 185 trocars. Three spore strips of paper impregnated were introduced in laparoscopic instrument within each preceded by cleaning type (4), packed in surgical paper and subjected to saturated steam sterilization under pressure (134oC for 5 minutes). With aseptic technique, each paper spore strip was inoculated into culture medium Tryptic Soy Broth (TSB) and incubated at 56oC for 21 days. No growth was observed, they were subjected to heat shock at 80oC for 20 minutes to stimulate germination, with more reincubation for 72 hours. There was no microbial growth in some samples of the experimental group. The results of the control groups were satisfactory. The Positive Control confirmed the challenge posed to experiments and the negative control presented results expected from the absence of growth. This study provides strong scientific evidence for the Centers for Material and Sterilization sustain the microbiological safety of the practice of sterilization of laparoscopic instruments assembled.
38

Risco biológico para o circulante de sala operatória / Biological risk to the transient of operating room

ALMEIDA, André Nunes Gomes de 07 July 2009 (has links)
Made available in DSpace on 2014-07-29T15:04:44Z (GMT). No. of bitstreams: 1 dissertacao andre almeida.pdf: 1781781 bytes, checksum: 6e6bcda130f6721b804c5d44db925528 (MD5) Previous issue date: 2009-07-07 / Employees of nursing during their work activities in the Surgical Center (SC), are exposed to various occupational hazards, among them biological. The objectives of this study were: to characterize vulnerabilities points to accidents involving biological material for the transient of the operating room (OR), in the trans-operative period and preparation of the Operating Room; to identify the adoption of universal precaution measures, identifying the occurrence of accidents with biological material and to determine the profile of accidents with biological material among circulating OR. Transversal descriptive study conducted with employees of nursing staff engaged in the activity of OR in the SC of a public teaching hospital in the city of Goiânia - GO. Data collection was performed using two instruments: a check list and application of a questionnaire both evaluated and tested. Filling out the checklist was it the first time of data collection that was done by direct observation of the activities of transients in the trans-operative care and dismantling the operating room, including the delivery of the material in the purge of the Centre of Material and Sterilization. Subsequently, a questionnaire was subject to the same observation. We met all the ethical issues for the consideration provided for in resolution 196 of the National Health Council. Data were grouped in tables and figures and descriptive statistics were used for frequency measurements. The data on the perception of transients regarding the observed behaviors were targeted on groups by hierarchical method, cluster analysis. Of the 37 eligible professionals, 30 participated. The majority (93.4%) female, working time in SC, for more than six years (56.6%) and half has another employment relationship, 40.0% with weekly working hours equal or above 60 hours. It was found that 56.6% of circulating never participates in training on biological risk and 34.0% learned the service following colleagues. The vaccine for hepatitis B was referred by 80.0% of workers, 40.0% had anti-HBs. No transient used protection goggles and 53.3% did not use closed shoes while working. Were reported several risk behaviors for exposure to biological material, among which stands out the use of procedure gloves to collect the instruments after surgery, the use of auxiliary table for carrying items such as: instrumental, glass suction, chamber using sharps; collected manually suture needles used in surgery. Disposal of sharps in the OR was predominantly inadequate and no review of the field after surgery occurred in 86.7%. Accidents with biological material were reported by 40.0% of transients, predominantly from percutaneous exposure to blood and only half have been informed about. Behavior characterized in this study, as risk of exposure to biological material, were recognized by circulating OR as present in the daily work, it was possible to observe concordance between both events (high-frequency behavior and high alert as a gift) and disagreement ( high frequency of observation with low alert) with the predominance of agreement. For all behaviors considered as risk of exposure to biological material there was recognition that this occurs. Some behaviors of transient increase the risk to workers from other units of the hospital. The results indicate the need for organizational and administrative changes to the confrontation of the biological risk inherent in the work of the transient of the operating room. Highlighted the need to intensify educational measures regarding the promotion of a safe environment for workers to be frequently reminded that their work exposes them to risks, and risks can be minimized through adherence to standard precautions / Os trabalhadores da enfermagem, durante suas atividades laborais no Centro Cirúrgico (CC), estão expostos aos diferentes riscos ocupacionais, dentre eles o biológico. Os objetivos deste estudo foram: caracterizar pontos vulneráveis para acidentes com material biológico para o circulante de Sala Operatória (SO), no período trans-operatório e preparo da sala de operação; identificar a adoção de medidas de Precaução Padrão; identificar a ocorrência de acidentes com material biológico e estabelecer o perfil de acidentes com material biológico entre os circulantes de SO. Estudo descritivo transversal realizado com trabalhadores da equipe de enfermagem que exercem a atividade de circulante de SO no CC de um hospital público de ensino do município de Goiânia - GO. A coleta de dados foi realizada por meio de dois instrumentos: um check list e aplicação de um questionário, ambos avaliados e testados. O preenchimento do check list constituiu-se o primeiro momento da coleta de dados que foi realizado pela observação direta das atividades dos circulantes nos cuidados no trans-operatório e desmontagem da sala operatória, incluindo a entrega do material no expurgo do Centro de Material e Esterilização. Posteriormente, foi aplicado um questionário aos mesmos sujeitos da observação. Foram cumpridos todos os aspectos éticos aplicáveis ao estudo previstos na resolução 196 do Conselho Nacional de Saúde. Os dados foram agrupados em tabelas e figuras e foi utilizada a estatística descritiva pela medida de freqüência. Os dados referentes à percepção dos circulantes quanto aos comportamentos observados foram segmentados em grupos pelo método hierárquico, análise de cluster. Dos 37 profissionais elegíveis, 30 participaram. A maioria (93,4%) do sexo feminino; com tempo de trabalho no CC, há mais de seis anos (56,6%) e metade possui outro vínculo empregatício; 40,0% com carga horária semanal igual ou superior a 60 horas. Verificou-se que 56,6% circulantes nunca participam de capacitação sobre risco biológico e que 34,0% aprenderam o serviço acompanhando os colegas. A vacina para hepatite B foi referida por 80,0% dos trabalhadores, 40,0% fizeram o anti-HBs. Nenhum circulante usou óculos de proteção e 53,3% não usaram sapatos fechados durante o trabalho. Foram registrados diversos comportamentos de risco de exposição a material biológico, dentre eles se destaca o uso de luvas de procedimento para recolher o instrumental após a cirurgia; o uso da mesa auxiliar para transportar artigos como: instrumental, vidro de aspiração, cuba com perfurocortante; recolher manualmente agulhas de sutura usadas no procedimento cirúrgico. O descarte de perfurocortante na SO foi predominantemente inadequado e a não revisão dos campos após a cirurgia ocorreu em 86,7%. Acidentes com material biológico foram referidos por 40,0% dos circulantes, com predomínio da exposição percutânea a sangue e apenas metade notificou. Comportamentos caracterizados, neste estudo, como risco de exposição a material biológico, foram reconhecidos pelos circulantes de SO como presentes no cotidiano do trabalho, tendo sido possível observar tanto concordância entre os eventos (alta freqüência no comportamento e alta indicação como presente) como discordância (alta freqüência de observação com baixa indicação) com o predomínio de concordância. Para todos os comportamentos considerados como risco de exposição a material biológico houve reconhecimento de que isso ocorre. Algumas condutas dos circulantes potencializam o risco biológico para trabalhadores de outras unidades do hospital. Os resultados apontam para a necessidade de mudanças organizacional e administrativa, para o enfretamento do risco biológico inerente ao trabalho do circulante de sala operatória. Evidenciaram a necessidade de intensificar as ações educativas quanto às medidas de promoção de um ambiente seguro aos trabalhadores que devem ser, freqüentemente, lembrados de que seu trabalho os expõe a riscos, e que esses riscos podem ser minimizados por meio da adesão às precauções padrão.
39

Ansiedade pré-operatória em pacientes cirúrgicos hospitalizados de Goiânia-Go / Pre-operative anxiety in hospitalized surgical patients in Goiânia-Go

Melchior, Lorena Morena Rosa 20 March 2017 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-04-25T20:08:52Z No. of bitstreams: 2 Dissertação - Lorena Morena Rosa Melchior - 2017.pdf: 2293458 bytes, checksum: 1552ff2a26ec1415f63306425eea8876 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: A citação está com porblema : Dissertação (Programa de Pós-graduação em Enfermagem) on 2017-04-26T12:55:17Z (GMT) / Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-04-26T17:20:43Z No. of bitstreams: 2 Dissertação - Lorena Morena Rosa Melchior - 2017.pdf: 2293458 bytes, checksum: 1552ff2a26ec1415f63306425eea8876 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-27T11:38:59Z (GMT) No. of bitstreams: 2 Dissertação - Lorena Morena Rosa Melchior - 2017.pdf: 2293458 bytes, checksum: 1552ff2a26ec1415f63306425eea8876 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-27T11:38:59Z (GMT). No. of bitstreams: 2 Dissertação - Lorena Morena Rosa Melchior - 2017.pdf: 2293458 bytes, checksum: 1552ff2a26ec1415f63306425eea8876 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-20 / INTRODUCTION: The anesthetic-surgical procedure is a complex and critical process, a moment that can generate important implications for the patients, and can generate diverse feelings such as anxiety and fear. Preoperative anxiety has affected about 60 to 80% of surgical patients. The patient's emotionally unstable surgery is scary and traumatic and is still predisposed to complications. PURPOSE: To investigate the profile of anxious patients hospitalized in preoperative elective surgery. METHOD: A cross-sectional, analytical study with subsequent cohort formation, performed at a public university hospital in the city of Goiânia-GO, Brazil. The population consisted of preoperative elective surgery patients hospitalized in surgical units, the sample was constituted of 200 patients in the preoperative period, by means of a sample calculation. Four instruments were used, one structured with sociodemographic and clinical-surgical questions; The Hamilton anxiety scale; The numerical scale of pain and the admission card of the surgical center. The study was carried out in total accordance with the Resolution 466/2012 regarding ethical issues. The analysis was expressed in absolute and relative frequencies and the Chi-square test was employed, with a significance level of 5%. The Prevalence Ratio (PR) was evaluated through gross and adjusted Poisson regression. RESULTS: The prevalence of anxiety was 53,0% (n=106) (CI 95% 46,06/59,85), mild anxiety was present in 67,0% (n=71) (CI 95%; 57,6-75,4), and 33,0% (n=35) (CI 95% 24,5/42,3) of the patients presented moderate and severe anxiety. In the multivariate analysis, sex, occupation and fear of anesthesia were significant, configuring as predictors to moderate and severe anxiety. The fear of anesthesia, of something going wrong, or of dying emerged in a predominant part of the sample, and the fear of errors showed significant relation to moderate and severe anxiety. CONCLUSIONS: The prevalence of preoperative anxiety found in the study was high. Most of the anxious patients expressed levels of mild anxiety. The most common factors that led to anxiety were the fear of death and of errors by the surgical team. Sex, occupation and fear of anesthesia configured as predictors to moderate and severe anxiety. / INTRODUÇÃO: O procedimento anestésico-cirúrgico é um processo complexo e crítico, um momento capaz de gerar implicações importantes aos pacientes, podendo gerar diversos sentimentos como o de ansiedade e o medo. A ansiedade pré-operatória tem afetado cerca de 60 a 80% dos pacientes cirúrgicos. O paciente instável emocionalmente a cirurgia é algo assustador e traumático e ainda está predisposto a complicações. OBJETIVO: Investigar o perfil dos pacientes ansiosos hospitalizados em pré-operatório de cirurgia eletiva. MÉTODO: Estudo de delineamento transversal, analítico, com posterior formação de coorte, realizado num hospital universitário público do município de Goiânia-GO, Brasil. A população foi constituída por pacientes em pré-operatório de cirurgia eletiva internados em unidades cirúrgicas, a amostra foi constituída de 200 pacientes em pré-operatório, mediante cálculo amostral. Utilizou-se quatro instrumentos, um estruturado com questões sociodemográficas e clínico-cirúrgicas; a escala de ansiedade de Hamilton; a escala numérica de dor e a ficha de admissão do centro cirúrgico. O desenvolvimento do estudo atendeu integralmente à Resolução 466/2012, quanto às questões éticas. Realizou-se análise expressa em frequências absoluta e relativa e utilizou-se o teste qui-quadrado, considerando nível de significância de 5%. A Razão de Prevalência (RP) foi avaliada por meio da Regressão de Poisson bruta e ajustada. RESULTADOS: A prevalência de ansiedade pré-operatória foi 53,0% (n=106) (IC 95% 46,06/59,85), a ansiedade leve foi de 67,0% (n=71) (IC 95%; 57,6- 75,4), e 33,0% (n=35) (IC 95% 24,5/42,3) dos pacientes apresentaram ansiedade moderada e grave. O perfil dos ansiosos foi formado por pacientes na faixa etária entre 50 a 69 anos, mulheres, baixa escolaridade, casados, moradores do interior do estado de Goiás, em casas cujo provedor era único, trabalhadores informais/desempregados, não tabagistas/etilistas, com menos de 24 horas de internação, com experiência cirúrgica prévia, sem doenças crônicas e sem dor no pré-operatório. Na análise multivariada, o sexo, a ocupação e o medo da anestesia foram significativos, configurando-se em preditores para ansiedade moderada e grave. O medo da anestesia, de algo dar errado, ou de morrer, esteve em parte predominante da amostra e o medo de erros mostrou relação significante com a ansiedade moderada e grave. CONCLUSÕES: A prevalência de ansiedade pré- operatória encontrada foi alta, comparada a estudos semelhantes. A maioria dos pacientes ansiosos demonstrou níveis de ansiedade leve. O sexo, a ocupação e o medo da anestesia configuraram-se em preditores para ansiedade moderada e grave nos pacientes cirúrgicos.
40

Eficácia da esterilização a vapor de instrumental laparoscópico montado versus desmontado: um estudo experimental / Effectiveness of the steam sterilization of assembled versus disassembled laparoscopic instruments: an experimental study

Tamara Carolina de Camargo 30 March 2007 (has links)
A vídeo-laparoscopia é uma inovação tecnológica que trouxe indiscutíveis vantagens e também novos desafios, incluindo nestes, as diretrizes para o reprocessamento adequado dos instrumentais e seus acessórios. A autoclavação dos instrumentais laparoscópicos desmontados é mais segura, uma vez que a condução térmica é facilitada. No entanto, são artigos complexos, compostos por múltiplas peças e a sua remontagem no momento da cirurgia traz transtornos às equipes cirúrgicas, correndo o risco do não funcionamento ou de danos às peças pela montagem inadequada. Existe um arraigado conceito, entre os profissionais da saúde, que para o sucesso da esterilização ser alcançado, é necessário o contato direto do vapor com todas as superfícies dos materiais submetidos à autoclavação sem considerar também o raciocínio do calor latente. A destruição microbiana por meio da esterilização pelo vapor está essencialmente relacionada ao calor latente, gerado pela condensação deste em contato com a superfície fria do material, promovendo a termocoagulação das proteínas microbianas. É uma prática comum nos hospitais brasileiros a realização da autoclavação de instrumentos previamente montados, apesar de não haver comprovação científica consistente dessa prática. Isto posto, esta investigação teve o objetivo de avaliar a eficácia do processo de esterilização a vapor dos instrumentais laparoscópicos previamente montados, comparando os seus resultados com os desmontados, considerada neste estudo a melhor prática. Tratou-se de uma pesquisa experimental, laboratorial, com abordagem quantitativa. Foram selecionados dois modelos de maior complexidade dentre os instrumentos laparoscópicos para realização do estudo, sendo eles: trocarte com válvula tipo janela rosqueada de 5mm, composto por cinco peças desmontáveis e pinça para dissecção de 5mm, composta por quatro peças desmontáveis. Cada peça dos instrumentais foi considerada como uma unidade amostral na análise microbiológica. Este estudo teve então como Grupo Montado: instrumentais laparoscópicos montados; Grupo Desmontado: instrumentais laparoscópicos desmontados; Grupo Contagem Microbiana: instrumentais laparoscópicos submetidos aos procedimentos de contaminação desafio, encaminhados diretamente para o teste de contagem microbiana. O inóculo para a contaminação desafio constitui-se de suspensão do Geobacillus stearothermophilus, na forma esporulada, acrescido de sangue de carneiro desfibrinado esterilizado. Todos os instrumentais foram contaminados desmontados com o inóculo desafio. Os grupos Montado e Desmontado foram submetidos aos processos de limpeza manual, complementada pela limpeza automatizada em lavadora ultra-sônica com retrofluxo, enxágüe em água corrente e sob pressão. Por fim, foi realizado o enxágüe com água destilada esterilizada e secagem com ar comprimido medicinal. Na seqüência, foi realizado sorteio para composição dos Grupos Montado e Desmontado. Os instrumentais foram embalados individualmente em papel grau cirúrgico e submetidos à esterilização a vapor em autoclave com pré-vácuo. Após a esterilização, os instrumentais foram avaliados quanto à eficácia da esterilização, por meio dos resultados dos testes de cultura microbiológica, utilizando o método de inoculação direta. No Grupo Montado foram recuperados os microrganismos teste em três peças de uma mesma pinça (3/48) e em três peças de um mesmo trocarte (3/60), enquanto que no Grupo Desmontado o microrganismo teste não foi recuperado nas unidades amostrais estudadas. Nas condições desse experimento, os resultados obtidos refutaram a hipótese inicial da pesquisa quanto à segurança da autoclavação das pinças e dos trocartes utilizados em cirurgia laparoscópica previamente montados / The video laparoscopy is a technological innovation that brought unquestionable advantages and, also, new challenges, like: the policies for the adequate reprocessing of the instruments and its permanent accessories. The steam sterilization of disassembled laparoscopic instruments is much safer, once that the thermal conduction is facilitated. However, laparoscopic instruments are quite complex articles; they are composed by many parts and the reassemblage in site at the moment of the surgery brings many inconveniences to the surgical team, like the possibility of the instrument’s malfunctioning or non functioning at all, or even damages to the instruments due to inadequate assembling. There is a strong belief among the Healthcare Professionals about the necessity of the direct contact of the steam with all the surface of the materials submitted to the steam sterilization, which is correct, however it doesn´t consider the latent heat assumption as well. The destruction of the microbiological material throughout the steam sterilization is essentially related to the latent heat, created by the vapor condensation when in contact with the instrument´s cold surface, promoting the thermal-coagulation of microbiological proteins. Many hospitals use the steam sterilization of previously mounted instruments, although there´s not any consistent scientific evidence about the efficiency of this practice. Once stated this point, this investigation´s aim was: evaluate the effectiveness of the steam sterilization process of the previously mounted, permanent laparoscopic instruments. It was an experimental laboratorial research, using a quantitative approach. Two models of permanent laparoscopic instruments of major complexity were chosen for the experiments: a trocar with a 5mm screw window valve, composed by five dismountable parts and a 5mm dissection clamp, composed by four dismountable parts. Each part of the instruments was considered as a sample unit on the microbiological analysis. This study it had the Assembled Group was: mounted laparoscopic instruments; the Disassembled Group was: disassembled laparoscopic instruments; the Microbiological Counting Group was: laparoscopic instruments submitted to the - challenge contamination - procedures, being directed straight to the test of microbiological counting. The inoculants material used for the challenge contamination consisted on the suspension of the Geobacillus stearothermophilus, in its spore form, plus defibrinated and sterilized sheep blood. All the instruments were contaminated, disassembled with the challenge inoculants material. The Assembled and Disassembled groups were submitted to the manual cleaning processes, enhanced by the automatic cleaning in an ultrasonic washer with retro-flux, rinsed in running and under pressure water. At last, a rinsing with distilled water was performed; the drying process was made with medicinal compressed air. Then, a sorting was performed to decide about the composition of the Assembled and Disassembled groups. The instruments were individually packed in surgical paper and submitted to the steam sterilization in a pre-vacuum sterilizer machine. After the sterilization, the instruments were evaluated according to sterilization effectiveness throughout the microbiological culture test´s results, using the straight inoculation method. In the Assembled Group the microorganism´s tests were recovered in three parts of one same clamp (3/48) and in three parts of the same trocar (3/60), in the Disassembled Group the test microorganism wasn´t recovered in any of the sample unities. The results, under the conditions of the experiment, refuted the hypothesis of safety in the usage of the steam sterilization in previously mounted used clamps and trocar in laparoscopy

Page generated in 0.1198 seconds