Reflectância de orelha média na síndrome de Down / Wideband reflectance in Down syndrome

Soares, Jordana Costa 13 August 2013 (has links)
INTRODUÇÃO: A síndrome de Down apresenta elevados índices de alteração da função da orelha média, bem como malformações congênitas na orelha externa, média e interna. Tais condições podem interferir na transmissão sonora pelo sistema tímpano-ossicular até a cóclea e vias auditivas centrais, afetando a compreensão da linguagem falada. Uma recente ferramenta de avaliação da orelha média, a reflectância de energia de faixa ampla, pode quantificar a energia sonora refletida ou absorvida no meato acústico externo ao longo de uma ampla faixa de frequências, mais rapidamente do que a timpanometria. OBJETIVO: Comparar as medidas de reflectância de energia de faixa ampla entre crianças com síndrome de Down e um grupo controle pareado por idade, de acordo com os achados timpanométricos. MÉTODOS: Foram analisados os dados de quatro grupos com síndrome de Down, entre 28 e 195 meses, sendo: timpanometria normal (19 orelhas), timpanometria plana (13 orelhas), timpanometria com pressão negativa moderada (6 orelhas), timpanometria com pressão negativa severa (4 orelhas). Todos os achados foram comparados a um grupo controle (21 orelhas). Os participantes foram submetidos aos exames de timpanometria e reflexo acústico ipsilateral com frequência de sonda de 226 Hz., audiometria tonal limiar, limiar de reconhecimento de fala, emissões otoacústicas evocadas por estímulo transiente e reflectância de energia na faixa de 200 a 6000 Hz. com estímulos do tipo chirp e tons puros. RESULTADOS: Os cinco grupos estudados exibiram diferentes padrões de curvas de reflectância de energia, sem diferença significativa em algumas comparações. Houve correlação negativa entre o volume do meato acústico externo e a reflectância com estímulo chirp entre 250 e 1600 Hz. e com o estímulo de tons puros entre 258 e 1500 Hz., e entre o pico de admitância da timpanometria e a reflectância com estímulo chirp em 500 e 1000 Hz. Não houve correlação entre as frequências da reflectância com estímulo chirp em 1000 e 2000 Hz e os resultados das emissões otoacústicas em 1000, 2000 Hz. e Response. A técnica de análise discriminante utilizada para classificar os dados dos participantes com base nos valores da reflectância com estímulo chirp em 1000 e 1600 Hz., alcançou um índice de classificação correta de 60% para os participantes com síndrome de Down. CONCLUSÕES: Foi possível caracterizar a curva de respostas da orelha média, para diferentes timpanogramas, na síndrome de Down, por meio da reflectância de energia de faixa ampla. Crianças com síndrome de Down com timpanograma normal apresentaram curva de reflectância semelhante ao grupo controle. A análise discriminante por meio dos resultados da timpanometria e reflectância com estímulo chirp em 1600 e 1000 Hz. classificou corretamente 60% dos dados pesquisados nas crianças com síndrome de Down / INTRODUCTION: Children with Down syndrome have high incidence of disorders of the middle ear, as well as congenital abnormalities in the external, middle and inner ear. Such conditions may change the sound transmission through the ossicular chain to the cochlea and central auditory pathways, impairing the comprehension of spoken language. An recent assessment tool of the middle ear, the wideband reflectance energy, can measure the sound energy reflected or absorbed in the ear canal over a wide frequency range, faster than tympanometry. OBJECTIVE: To compare the wideband reflectance measurements between children with Down syndrome and a control group matched by age, according to the tympanometric findings. METHODS: This study evaluated four groups with Down syndrome, between 28 and 195 months: normal tympanogram (19 ears), flat tympanogram (13 ears), moderate negative pressure tympanogram (6 ears), severe negative pressure tympanogram (4 ears). All findings were compared to a control group (21 ears). The subjects underwent to tympanometry and acoustic reflex ipsilateral with a 226 Hz probe tone frequency, pure tone audiometry, speech recognition thresholds, transient otoacoustic emissions and wideband reflectance over the 200-6000 Hz range with chirp and tone stimuli. RESULTS: Results revealed that the five groups had different reflectance curves, without significant difference in some comparisons. There was a negative correlation between the volume of the external auditory meatus and the wideband reflectance with the chirp stimulus between 250 and 1600 Hz and with the tone stimulus between 258 and 1500 Hz, and between the static acoustic admittance at the tympanic membrane level and the wideband reflectance with chirp stimulus at 500 and 1000 Hz. There was no correlation between the frequency of the chirp stimulus with reflectance at 1000 and 2000 Hz and the results of the otoacoustic emissions at 1000, 2000 Hz and general response. The discriminant analysis technique used to classify participants\' data based on the values of reflectance with chirp stimulus in 1000 and 1600 Hz, achieved a correct classification rate of 60% for participants with Down syndrome. CONCLUSIONS: The findings showed the responses of the middle ear, for different tympanograms in Down syndrome through the wideband reflectance. In this study, children with Down syndrome and normal tympanogram showed wideband reflectance curve similar to the control group. A discriminant analysis with the tympanometric results and reflectance with chirp stimulus at 1600 and 1000 Hz correctly classified 60% of the data for children with Down syndrome
22

Efeito da estimulação contralateral nas medidas de reflectância acústica / Effect of contralateral stimulation on acoustic reflectance measurements

Pichelli, Tathiany Silva 22 November 2013 (has links)
Introdução: A Reflectância acústica é um procedimento introduzido mais recentemente na clínica audiológica, cuja abrangência diagnóstica pode ainda ser explorada. Suas medidas têm sido citadas como uma importante ferramenta na avaliação das afecções da orelha média, sendo um método considerado vantajoso em relação à timpanometria. Tem havido crescente interesse no estudo da estimulação acústica contralateral e seu efeito na ativação da via eferente auditiva. Estudos têm demonstrado que a introdução de estímulo simultâneo na orelha contralateral gera mudanças no padrão de respostas auditivas, tanto em medidas de emissões otoacústicas como em imitância acústica. Desta forma, surgiu o interesse em investigar a ocorrência de mudanças no padrão de resposta da curva de reflectância, quando pesquisada com a aplicação de ruído de banda larga na orelha contralateral. Objetivo: Verificar a influência da estimulação contralateral nas medidas de reflectância acústica da orelha média em adultos jovens. Metodologia: A casuística foi composta por 30 participantes de ambos os gêneros, na faixa etária de 18 a 30 anos. Procedimentos: Inspeção do meato acústico externo; Imitanciometria; Audiometria tonal limiar; Pesquisa do limiar de ruído branco; Pesquisa da Reflectância Acústica em dois passos: (a) foi obtida a curva de reflectância no intervalo de frequência de 200 a 6000 Hz na intensidade de 60dB SPL utilizando-se os estímulos chirp e de tons puros, e (b) o procedimento foi repetido com os mesmos parâmetros e estímulos, com a presença de ruído contralateral simultâneo por meio de fones de inserção a 30 dBNS em relação ao limiar de ruído branco. Resultados: Os resultados apontaram que não existem diferenças quando comparados gêneros. Quando a análise foi realizada separadamente por orelha houve diferenças entre estímulos chirp e de tons puros nas frequências de 1,5 e 2 kHz em orelha direita. Entre as condições de teste e reteste as diferenças estatísticas foram nas frequências de 0,25 e 0,5 kHz em orelha direita para estímulo de tons puros. A análise entre as condições de teste, reteste e teste com ruído contralateral apresentou diferença estatística na frequência de 2 kHz (pvalor 0,011 em teste e 0,002 em reteste) para estímulo chirp em orelha direita. A comparação entre orelhas esquerda e direita identificou diferenças estatísticas nas frequências de 3 e 4 kHz para os dois tipos de estímulos utilizados. Conclusão: Este estudo permite concluir que a ativação da via auditiva eferente por meio da estimulação acústica contralateral com ruído branco produz mudanças nos padrões de respostas da reflectância acústica, aumentando suas respostas e modificando a transferência de energia sonora da orelha média / Introduction: The acoustic reflectance is a procedure introduced more recently in audiology, which diagnostic scope can be further explored. Its measurements have been cited as an important instrument in the evaluation of middle ear affections, as a method considered advantageous in relation to tympanometry. There has been growing interest in the study of contralateral acoustic stimulation and its effect on activation of the auditory efferent pathway. Studies have shown that the introduction of simultaneous stimulation in the contralateral ear generates changes in the pattern of auditory responses in both measures of otoacoustic emissions as in acoustic impedance. Therefore, emerged the interest in investigating the occurrence of changes in the response pattern of the reflectance curve when studied with the application of broadband noise in the contralateral ear. Objective: Investigate the influence of contralateral stimulation on acoustic reflectance measurements of the middle ear in young adults. Methods: The sample consisted of 30 participants of both genders, aged 18-30 years. Procedures: Inspection of the external acoustic meatus; imitanciometry; pure tone audiometry threshold; threshold research of White Noise; acoustics reflectance research in two steps: (a) obtaining of reflectance curve in the frequency range 200-6000 Hz in the intensity of 60dB SPL using chirp stimuli and pure tone, and (b) repeating the procedure with the same parameters and stimuli with contralateral noise simultaneously through insert earphones at 30 dBNS over the white noise threshold. Results: The results presented no difference compared genres. The analysis performed separately by ear presented differences between chirp stimuli and pure tone at frequencies of 1.5 and 2 kHz in the right ear. Between test and retest conditions the statistical differences in frequencies were at frequencies of 0.25 and of 0.5 kHz in the right ear for pure tone. Analysis of the conditions of test, retest and test with contralateral noise presented statistical difference at the frequency of 2 kHz (pvalue on test 0.011 and 0.002 on retest) for chirp stimulus in the right ear. The comparison between left and right ears identified statistical differences at the frequencies of 3 and 4 kHz for the two types of stimuli used. Conclusion: This study shows that the activation of the efferent auditory pathway by contralateral acoustic stimulation with white noise produces changes in response patterns of acoustic reflectance, increasing their responses and modifying the transfer of sound energy from the middle ear
23

Padrão de análise da timpanometria com sonda de 226 Hz na criança considerando a pressão do pico de máxima compliância e a compliância estática / Tympanometry analysis standard with 226 Hz of age six months to three years considering the pressure of the peak of maximum compliance and the static compliance

Alana Ribeiro de Melo 08 May 2017 (has links)
A análise precisa dos resultados da timpanometria é essencial para determinar a condição da orelha média, principalmente em crianças nos primeiros anos de vida. Assim, o objetivo deste estudo foi apresentar um padrão de análise da timpanometria com sonda de 226 Hz para a faixa etária de seis meses a três anos, considerando a pressão do pico de máxima compliância e a compliância estática. Foram analisados prontuários de crianças de seis meses a três anos de idade atendidas no período de outubro de 2012 a fevereiro de 2016 no Centro de Pesquisas Audiológicas - Seção de Implante Coclear do Hospital de Reabilitação de Anomalias Craniofaciais e na Clínica de Audiologia Infantil da Clínica de Fonoaudiologia da Faculdade de Odontologia de Bauru, ambos da Universidade de São Paulo. A casuística foi dividida em dois grupos: grupo sem alteração de orelha média, composto por 224 orelhas, e o grupo com alteração de orelha média, composto por 59 orelhas. Foram considerados para análise os valores de pressão do pico de máxima compliância (daPa) e de compliância estática (ml) obtidos na timpanometria com sonda de 226Hz. No grupo sem alteração, o Teste Correlação Mann Whitney revelou que não houve diferença significante entre os sexos para pressão do pico de máxima compliância (p=0,782) e para a compliância estática (p=0,085). Também não houve correlação dos valores de pressão (p=0,678) e compliância (p=0,079) com a idade, de acordo com o Teste Correlação de Spearman. Considerando o intervalo entre os percentis 2,5 e 97,5 obtidos para a pressão e compliância nos grupos sem e com alteração, observou-se uma faixa de valores comum aos dois grupos, ou seja, os valores contidos nesta faixa não conseguiram classificar a orelha média como normal ou alterada. De acordo com os percentis 2,5 e 97,5, foi possível estabelecer uma faixa de normalidade para a pressão do pico de máxima compliância, de +52 daPa a -100 daPa, e para compliância estática, de 0,20 ml a 0,68 ml. Enquanto que na faixa de alteração, os valores variaram de -259 a 17,52 daPa para pressão e de 0,04 a 0,41 ml para a compliância. Assim, uma faixa de intersecção foi identificada, correspondente ao intervalo de -100 a 17,52 daPa para pressão do pico de máxima compliância e de 0,2 a 0,41 ml para a compliância estática. A análise dos dados demonstrou que a timpanometria com sonda de 226 Hz apresentou alta sensibilidade e baixa especificidade na faixa etária de seis meses a três anos. / Accurate analysis of tympanometry results is essential to determine the condition of the middle ear, especially in children in their first years of life. Thus, this study aimed at presenting a standard analysis of tympanometry with a 226 Hz probe for the age range six months to three years, taking into account the pressure of the peak of maximum compliance and static compliance. The records of 6-month to three-year old children assisted from October 2012 to February 2016 at the Audiology Research Center - Cochlear Implant Section of the Craniofacial Anomalies Rehabilitation Hospital and at the Children\'s Audiology Clinic of the Audiology and Speech-Language Pathology Clinic of the Bauru Dentistry School, both of the University of São Paulo, were analyzed. The sample was divided into two groups: a group with no middle ear alteration comprising 224 ears and the group with middle ear alteration composed of 59 ears. For analysis, the pressure values of the maximum compliance peak (daPa) and static compliance (ml) obtained in the tympanometry with a 226Hz probe were considered. In the group with no alteration, the Mann Whitney Correlation Test showed no significant difference between the genders for the maximum compliance peak pressure (p = 0.782) and for static compliance (p = 0.085). No difference was seen, either, for pressure (p = 0.678) and compliance (p = 0.079) values, according to age, by using the Spearman Correlation Test. Considering the interval between percentiles 2,5 and 97,5 obtained for pressure and compliance in the groups without and with alteration, a range of values common for the two groups was observed, that is, the values contained in this range could not classify the Middle ear as normal or altered. According to percentiles 2,5 and 97,5, it was possible to establish a range of normality for the pressure of the maximum compliance peak, from +52 daPa to -100 daPa, and for static compliance, from 0.20 ml to 0.68 ml, while in the alteration range, values ranged from -259 to 17,52 daPa for pressure and from 0,04 to 0,41 ml for compliance. Thus, an intersection range was identified, corresponding to the interval of -100 to 17,52 daPa for the pressure of the maximum compliance peak and 0,2 to 0,41 ml for the static compliance. Data analysis showed that tympanometry with a 226 Hz probe presented high sensitivity and low specificity in the 6-month to 3-year age range.
24

Função da orelha média e das curvas de crescimento nas respostas das emissões otoacústicas / Middle-ear and growth functions on the responses of the otoacoustic emissions

Campos, Ualace de Paula 28 June 2011 (has links)
INTRODUÇÃO: Dentre as medidas da função coclear, a curva de crescimento das Emissões Otoacústicas por produto de distorção (CCEOA PD) permite o registro da amplitude da emissão em função do crescimento sistemático nos níveis de tons primários. A CCEOA PD fornece parâmetros específicos sobre o limiar e o comportamento não-linear das EOA PD, porém a variabilidade das respostas inter e intrasujeitos reduz a confiabilidade dessa medida na avaliação da robustez das respostas cocleares e a relação dessa robustez com os limiares auditivos. OBJETIVOS: Esta pesquisa estudou as interações entre as medidas timpanométricas da orelha média e as medidas de função coclear em adultos jovens sem queixas auditivas, de acordo com as variáveis: antecedentes de alterações de orelha média, sexo e orelha direita / esquerda. MÉTODOS: Participaram 69 indivíduos com audição normal e idades entre 18 e 34 anos, sendo 21 homens e 48 mulheres. A caracterização das condições de orelha média foi obtida pela anamnese, com a informação dos antecedentes de alterações de orelha média e pela timpanometria com sondas de admitância de 226 e 1000 Hz. A audiometria foi realizada com resolução de 01 dB NA, o que possibilitou comparações mais refinadas entre o limiar psicoacústico da audiometria tonal, a amplitude do DP-Gram e os limiares das CCEOA PD. Além dessas variáveis, a interferência dos fatores sexo e orelha foram testadas em todas as análises. RESULTADOS/DISCUSSÃO: Os resultados apontaram que as curvas de crescimento sofreram influência significativa das variáveis sexo, antecedentes de alterações de orelha média e orelha direita \\ esquerda, porém, apenas a interferência dos antecedentes foi constante e causou um padrão de modificação, ou seja, o grupo com antecedentes apresentou respostas aquém das respostas do grupo sem antecedentes. Os limiares audiométricos também apresentaram alta correlação com as amplitudes das EOA PD e com os limiares das CCEOA PD, quando identificadas as variáveis que interferiram nos resultados. Considerando que o ruído de fundo foi controlado nessa pesquisa, durante a avaliação das EOA PD e CCEOA PD, os resultados confirmaram a importância da consideração dessas variáveis na composição de grupos com audição normal em pesquisas com medidas de emissões otoacústicas. Ainda sobre os resultados, foi possível, por meio da medida da curva de crescimento (slope e limiar), demonstrar que o padrão de crescimento das CCEOA PD é diferente nos casos de modificação nas condições de orelha média e isso foi verificado tanto pelos antecedentes de alterações de orelha média quanto pelas medidas timpanométricas com sonda de admitância de 1000 Hz. CONCLUSÃO: O limiar das CCEOA - PD estudado nessa pesquisa apresentou correlação positiva com valores audiométricos e negativa com o DP-Gram. A inclinação da curva de crescimento (slope) também apresentou alta correlação com os antecedentes de alterações de orelha média, apontando o potencial valor desta medida no estudo da função coclear saudável e alterada e, conseqüentemente, sua possível utilização nas medidas prescritivas de amplificação / INTRODUCTION: The Distortion Product Otoacoustic Emissions Input/Output function (DPOAE I/O function) is a subdivision of DPOAE, where the response amplitude is recorded such as a systematic growth function in the primary tones. The DPOAE I/O function provides specific parameters about the DPOAEs threshold and non-linearity. However, the response variability reduces the measure reliability to evaluate the cochlear robustness and the relationship between robustness and hearing thresholds. OBJECTIVE: This research studied the interaction between the tympanometric measures and cochlear functions measures in young adults without hearing complaints, considering the variables: middle-ear alteration antecedents, gender and right / left ear. METHODS: 69 normal hearing subjects, aged from 18 to 34 years participated of the study. From the total, 21 were men and 48 women. To reach the proposed objectives, the middle ear conditions were assessed by anamneses and 226 and 1000 Hz admittance probe-tone tympanometry. The audiometric thresholds were searched with 01 dBHL resolution to enable refined comparisons among pure-tone audiometry and DP-Gram amplitude and DPOAE I/O function thresholds. The gender and ear interference were also evaluated in all analyses. RESULTS/DISCUSSION: The results showed that the variables gender, antecedents and ear affected the I/O functions responses, but only the middle-ear alterations antecedents presented a constant modification pattern. In other words, the group with antecedents presented mainly reduced responses in comparison with no antecedents group. The audiometric thresholds also presented high correlation with DPOAE amplitudes and DPOAE I/O functions thresholds, after the detection of the variables affecting the results. As the background noise was controlled during this study, the results confirmed the importance of monitoring these variables in the normal hearing group compositions to perform researches with DPOAE. Regarding the DPOAE I/O functions (slope and threshold), the growth pattern was modified according the middle ear conditions, verified by the antecedents of middle ear alterations and 1000 Hz admittance probe-tone tympanometry. CONCLUSION: The DPOAE I/O function threshold studied presented positive correlation with audiometric thresholds and negative correlation with DP-Gram. The DPOAE I/O functions slope also showed high correlation with antecedents of middle ear alterations, denoting the potential value of this measure in the study of the healthy and damaged cochlear function and, hence, it possible application in amplification prescriptive measures
25

Reflectância de banda larga em recém-nascidos: uso combinado de procedimentos eletroacústicos / Wideband reflectance in newborns: combined use of electroacoustic procedures

Silva, Kilza de Arruda Lyra e 16 December 2011 (has links)
INTRODUÇÃO: Os resultados da triagem auditiva neonatal podem ser afetados por condições transientes no meato acústico externo e na orelha média. A reflectância de banda larga (RBL) surge como um instrumento de diagnóstico que fornece medidas objetivas do estado da orelha média e pode explicar variações na forma de como a orelha média recebe, absorve e transmite a energia sonora. Dessa forma, a RBL apresenta um grande potencial para a detecção de alterações de orelha média em recém-nascidos. OBJETIVO: Verificar a correlação entre as medidas de reflectância da energia de banda larga com as medidas das emissões otoacústicas e as imitanciométricas em recém-nascidos. MÉTODO: Estudo de casos. Para este estudo foram avaliados 77 recém-nascidos (40 do sexo masculino e 37 do feminino) de idades entre 27 e 78h sem riscos para perda auditiva segundo o JCHI (2007), e com emissões otoacústicas presentes por estímulo transiente (EOAT). Foram submetidos ao teste das mediadas de EOAT, da reflectância da energia com os estímulos chirp e tom puro numa faixa de 0.2 a 6 kHz, e da timpanometria e reflexo acústico ipsilateral com as frequências da sonda de 226 e 1000 Hz. Os estímulos ativadores de 1000 e 2000 Hz e ruído de banda larga foram usados no reflexo acústico. RESULTADOS: Os resultados apontaram que os recém-nascidos com EAOT presentes revelaram uma configuração de curva da reflectância com característica peculiar da idade, ou seja, baixa reflectância na frequência de 6000 Hz. O timpanograma de curva do tipo A foi obtido em 90,2% das orelhas com a sonda de 1000 Hz, e com a sonda de 226 Hz a maioria (89%) das orelhas apresentaram curva do tipo pico duplo. A configuração da curva 3B/3G foi apresentada em 69,8% das orelhas na sonda de 226 Hz, e as configurações 1B/1G (43%) e 1B/1G S (27%) juntas foram obtidas em 70% das orelhas. Na sonda de 1000 Hz os recém-nascidos avaliados apresentaram 100% de presença dos reflexos acústicos ipsilaterais para estímulos ativadores de 2000 Hz e ruído branco. Não houve diferença significativa entre os resultados do sexo masculino e do feminino. CONCLUSÃO: Este estudo demonstrou que a inter-relação entre o nível de amplitude das EOAT, a configuração timpanométrica B/G e a reflectância apresentou diferenças no comportamento por orelha. Algumas frequências e configurações B/G indicaram uma tendência da diminuição de EOAT com o aumento da reflectância. Dada a equivalência entre os estímulos chirp e tom puro, qualquer um pode ser usado para avaliação da orelha média em recém-nascidos / INTRODUCTION: Newborn hearing screening test outcomes can be influenced by transient conditions in the ear canal and middle ear. Wideband reflectance (WBR) emerges as a diagnostic tool that provides objective measures of the status of the middle ear and can explain variations in how the middle ear receives, absorbs and transmits sound energy. Thus, the WRL has a great potential for the detection of middle ear disorders in newborns. OBJECTIVE: To verify the correlation between wideband reflectance power measurement with otoacoustic emissions and immittance measurement in newborns. METHOD: Case studies. This study evaluated 77 newborns (40 males and 37 females) aged from 27 to 78 hours without risk of hearing loss according to JCHI (2007), and transient evoked otoacoustic emissions present (TEOAE). The newborns underwent the test of TEOAE measurement, the power reflectance using both tone and chirp stimuli from 0.2 to 6 kHz, and 226 and 1000 Hz admittance probe-tone tympanometry and ipsilateral acoustic reflex. The stimuli triggers 1000 and 2000 Hz and broadband noise were used in the acoustic reflex. RESULTS: Results showed that newborns with EAOT present revealed a configuration of the reflectance curve, peculiar feature of the age, i.e., low reflectance in the frequency of 6000 Hz. Single-peaked tympanogram was obtained in 90.2% of ears using a 1000 Hz probe tone, and double-peaked tympanogram was found in 89% of the ears using a 226 Hz probe tone. The 3B/3G tympanograms were found in 69.8% of the ears at 226 Hz probe tone, and the tympanograms 1B/1G (43%) and 1B/1G S (27%) together were obtained in 70% of the ears. In the 1000 Hz probe tone newborns evaluated showed 100% presence of ipsilateral acoustic reflexes to activating stimuli of 2000 Hz and white noise. No significant differences were obtained across gender considering the results of all test evaluated in newborns. CONCLUSION: This study demonstrated that the inter-relationship between the level of TEOAE amplitude, tympanometric configuration B/G and reflectance showed differences according in the ear. Some frequencies and configurations B/G indicated a trend of TEOAE decreasing of TEOAE with reflectance increasing. Given the equivalence between the tone and chirp stimuli, any of them can be used to evaluate the middle ear in newborns
26

Estudo clínico prospectivo randomizado comparando interposição de bigorna autóloga com nenhuma reconstrução ossicular em pacientes com descontinuidade ossicular incompleta submetidos à timpanoplastia por otite média crônica supurativa não colesteatomatosa

Sarmento Junior, Krishnamurti Matos de Araujo 26 April 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-10-05T16:55:45Z No. of bitstreams: 1 2018_KrishnamurtiMatosdeAraujoSarmentoJunior.pdf: 13327631 bytes, checksum: 0886205b614188e914ff0b36bc651114 (MD5) / Approved for entry into archive by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-10-09T20:35:11Z (GMT) No. of bitstreams: 1 2018_KrishnamurtiMatosdeAraujoSarmentoJunior.pdf: 13327631 bytes, checksum: 0886205b614188e914ff0b36bc651114 (MD5) / Made available in DSpace on 2018-10-09T20:35:11Z (GMT). No. of bitstreams: 1 2018_KrishnamurtiMatosdeAraujoSarmentoJunior.pdf: 13327631 bytes, checksum: 0886205b614188e914ff0b36bc651114 (MD5) Previous issue date: 2018-10-09 / INTRODUÇÃO: As otites médias crônicas supurativas podem causar erosão dos ossículos e uma descontinuidade da cadeia ossicular, que pode ser completa, quando algum dos ossículos perde contato com o outro, ou incompleta, quando a erosão entre os ossículos é insuficiente para desconectá-los. Este é o primeiro estudo que compara abordagens na descontinuidade ossicular incompleta (DOI). OBJETIVO: Comparar o resultado funcional auditivo da interposição de bigorna autóloga com o de nenhuma reconstrução ossicular em pacientes com DOI submetidos à timpanoplastia por otite média crônica não colesteatomatosa (OMCNC). CASUÍSTICA E MÉTODOS: Para definir o melhor desenho para o estudo clínico principal, procedeu-se inicialmente uma análise retrospectiva de uma série de 42 casos de DOI submetidos à timpanoplastia sem reconstrução ossicular. O resultado auditivo geral dessas cirurgias foi bom, mas havia um subgrupo com resultados muito ruins, incluindo 6 casos (17%) em que a audição não melhorou ou até piorou. Formulamos a hipótese de que esses seriam os casos em que não havia mais contato ósseo entre bigorna e estribo, com a conexão sendo feita predominantemente por tecido mole (granulação ou fibrose). Denominamos a primeira situação (com contato ósseo) de DOI tipo 1 e a segunda (contato apenas por tecido mole) de DOI tipo 2. Procedeu-se então um estudo clínico, prospectivo, randomizado, controlado, conduzido por um período de 5 anos, no Hospital Geral de Bonsucesso, que comparou a reconstrução ossicular pela técnica de interposição de bigorna autóloga com a não reconstrução, em pacientes submetidos à timpanoplastia por OMCNC com DOI por erosão parcial da bigorna. Conforme os achados peroperatórios, os pacientes foram divididos em um grupo de DOI tipo 1 (grupo 1) e outro de DOI tipo 2 (grupo 2). Dentro de cada grupo, a intervenção foi randomizada entre nenhuma reconstrução (subgrupos 1A e 2A) ou reconstrução por interposição de bigorna autóloga remodelada (subgrupos 1B e 2B). RESULTADOS: Não houve diferença estatística entre os grupos e subgrupos quanto a gênero, idade, tamanho da perfuração e episódios de otorreia nos 3 meses prévios à cirurgia. No grupo 2 o intervalo aéreo-ósseo (IAO) médio pré-operatório foi significativamente maior que o mesmo parâmetro no grupo 1 (37,8 dB contra 33,2 dB, p=0,009), sem diferença entre os subgrupos. Quanto ao resultado funcional da intervenção, no grupo 1 não houve diferença significativa entre os subgrupos, ao passo que no grupo 2, o subgrupo submetido à interposição de bigorna apresentou resultados significativamente superiores ao subgrupo sem reconstrução, tanto no que diz respeito ao IAO médio pós-operatório (15 dB contra 27,5 dB, p=0,006), quanto na porcentagem de casos com IAO médio pós-operatório menor ou igual a 20 dB (75% contra 31%, p=0,0013). CONCLUSÃO: A distinção entre DOI tipos 1 e 2 mostrou-se relevante, uma vez que estas apresentam comportamentos distintos quando não reconstruídas na cirurgia. Na DOI tipo 1, não houve diferença do resultado funcional entre não reconstruir e reconstruir com interposição de bigorna. Já nos casos de DOI tipo 2, o resultado funcional da interposição de bigorna autóloga foi superior ao de nenhuma reconstrução ossicular nos pacientes estudados. / INTRODUCTION: Suppurative chronic otitis media (SCOM) may lead to erosion of the ossicles and discontinuity of the ossicular chain. This discontinuity may be complete, with no contact between the disconnected ends, or incomplete, with normal contact replaced by soft tissue or by contact between opposing bones. This is the first study to compare different approaches in cases of incomplete ossicular discontinuity (IOD). OBJECTIVE: To compare the functional results of patients with non-cholesteatomatous SCOM and IOD submitted to either autologous incus interposition or no ossicular reconstruction. METHODS: To help determine the best design for a prospective surgical trial, we first looked retrospectively at a series of 42 cases of IOD that underwent, at surgeon´s discretion, type I tympanoplasties without ossicular reconstruction. The overall hearing outcome was good, but a closer look revealed a rather unequal distribution of hearing results, including 6 cases (17%) in which, despite closure of the perforation, the ABG remained the same or even worsened.We hypothesized that the better results were the cases in which there was still bony contact between incus and stapes (type 1 IOD), as opposed to the ones connected only (or mainly) by soft (granulation or fibrous) tissue (type 2 IOD). We then conducted a prospective, randomized surgical trial comparing no intervention with autologous incus interposition, in patients who underwent tympanoplasty for non-cholesteatomatous SCOM and presented with IOD, over a 5-year period, at a tertiary referral hospital. According to the intraoperative findings of IOD types 1 or 2, patients were respectively assigned to groups 1 and 2. In each group, patients were randomized between incus interposition (subgroups 1B and 2B) or no ossicular reconstruction (subgroups 1A and 2A). RESULTS: There was no statistical differences amongst groups and subgroups in age, sex, size of perforation and episodes of ear discharge 3 months before surgery. In group 2, the preoperative air-bone gap (ABG) was significantly higher (37.8 dB against 33.2 dB in group 1, p=0,009), but no differences in subgroups were found. There were no statistical differences in the hearing outcome of incus interposition and no reconstruction within group 1. On the other hand, in group 2, the subgroup who underwent incus interposition had significantly better results compared to the subgroup without ossiculoplasty. This was true for both postoperative ABG average (15 dB against 27.5 dB, p=0,006) and percentage of cases with postoperative ABG average equal to or less than 20 dB (75% against 31%, p=0,0013). CONCLUSION: The distinction between IOD types 1 and 2 is proven relevant because they have distinct outcomes when the ossicular defect is left without reconstruction. In Type 1 IOD, the postoperative hearing results of reconstructing or not were similar. In Type 2 IOD the results clearly favor reconstruction.
27

Angiogênese e metaloproteinases 2 e 9 : estudo comparativo entre colesteatomas adquiridos de pacientes pediátricos e adultos

Dornelles, Cristina de Carvalho January 2008 (has links)
A quantificação da angiogênese e das metaloproteinases pode ser útil na avaliação do comportamento dos colesteatomas, como marcadores de sua agressividade. Objetivo: Comparar os marcadores CD31, MMP2 e MMP9 entre pacientes pediátricos e adultos. Método: transversal. Grupos pediátricos(até 18 anos) e adultos(a partir de 19 anos). Coletados 120 colesteatomas, fixados em formol a 10%, preparadas cinco lâminas, de cada amostra, por técnicas histológicas habituais, observados: número de vasos sangüíneos(CD 31), marcação com MMP2 e MMP9, número de células na matriz e espessura na perimatriz. Dados analisados no SPSS através coeficiente Spearman, exato de Fisher e Mann-Whitney. Resultados: Colesteatomas distribuídos igualmente: 60 pediátricos(11,77±3,57anos); 60 adultos(38,29±14,51anos). CD31pediátrico 7(4 a 11), CD31adulto 4(0 a 10) (P=0,044). MMP2citoplasmática pediátrico 1(0 a 3), MMP2citoplasmática adulto 0(0 a 1) (P=0,006). MMP2nuclear pediátrico 0(0 a 1), MMP2nuclear adulto 0(0 a 1) (P=0,056). MMP9 pediátrico 2(0 a 4), MMP9 adulto 0(0 a 4) (P=0,049). O número de vasos sangüíneos e a quantificação das metaloproteinases estavam fortemente correlacionados com a espessura da perimatriz. Conclusões: Os colesteatomas pediátricos apresentam um grau inflamatório mais exacerbado, produzem mais metaloproteinases, fatores estes, que conjugados, poderiam caracterizar os colesteatomas pediátricos como mais agressivos que os colesteatomas adultos. / Cholesteatoma is an epidermal cyst with three distinct components: matrix, perimatrix and cystic content. The clinical significance of cholesteatoma lies in its association with potential intracranial complications due to bone destruction. Objective: To compare histological and immunohistochemistry analysis between pediatric and adult acquired. Methods: Cross-sectional study. The patients were divided in two groups, according to their age: 60 adults(>18 years old) and 60 children(until 18 years old). The cholesteatomas were fixed in formalin 10%. Five slides from each sample were prepared using standard histology techniques. Slides were analyzed according to average number of blood vessels (CD31), MMP2 and MMP9 positivity and thickness of the perimatrix. Data were analyzed using Mann-Whitney and Fisher's exact tests and Spearmann coeficient, with P values<0.05 considered significant. Results: Perimatrix thickness was 78(34-217); CD31 was 6(0-11), cytoplasmic MMP2 positivity was 0(0-2), nuclear MMP2 positivity was 0(0-1); MMP9 positivity was 2(0-4). Statistical difference, between children and adults, was found in perimatrix thickness(P=0.014); blood vessels(P=0.044); cytoplasmic MMP2(P=0.006), nuclear MMP2(P=0.056); MMP9(P=0.049). Conclusions: Pediatric cholesteatomas have a thicker perimatrix, a greater degree of inflammation, and produce more metalloproteinases than those of adult patients, we can suggest, with the combination of these factors, that cholesteatoma is more aggressive in children than in adults.
28

Estudo da função da tuba de eustáquio em pacientes com retrações da membrana timpânica e em indivíduos normais / Assessment of eustachian tube function in patients with tympanic membrane retraction and in normal subjects

Canali, Inesângela January 2013 (has links)
Introdução: O diagnóstico das disfunções da tuba auditiva é essencial para o melhor entendimento da patogênese da otite média crônica. Estão descritos, na literatura, uma série de testes que avaliam a função tubária, entretanto, entre eles, há uma diversidade metodológica que varia desde os protocolos de aplicação até a padronização dos testes e seus resultados. Objetivo: Avaliar a variação da pressão na orelha média em pacientes com retração da membrana timpânica e em indivíduos normais, durante a realização dos testes de função tubária, bem como avaliar a variação intraindividual desses testes. Este estudo também tem por objetivo avaliar o número de movimentações da membrana timpânica na orelha contralateral, durante a realização dos testes. Métodos: Estudo observacional do tipo transversal e contemporâneo, onde o fator em estudo foi a variação de pressão na orelha média, durante a realização dos testes de função tubária (Manobra de Valsalva, Sniff Test, Manobra de Toynbee) em indivíduos normais e em pacientes com retrações timpânicas leves e moderadas/severas. Foram incluídos 38 pacientes, totalizando 76 orelhas. Os pacientes foram submetidos, em dois momentos diferentes, aos testes de função tubária para determinar a medida da pressão após cada manobra. Durante a realização dos testes, videotoscopia era realizada concomitantemente na outra orelha, a fim de se observar a movimentação da membrana timpânica. A análise estatística foi realizada por meio do programa SPSS versão 18.0, em que foram considerados como estatisticamente significativos os valores de p< 0,05. Resultados: A média ± desvio-padrão da idade foi de 11 ± 2,72 anos; 55,3% dos pacientes foram do sexo masculino e 44,7% do sexo feminino. A prevalência de curva A foi maior nos grupos de orelhas normais e retrações leves, enquanto que de curva C foi maior no grupo de retrações moderadas/severas. Observamos aumento das pressões na orelha média durante a realização da Manobra de Valsalva no primeiro momento de avaliação nos três grupos de orelhas (p= 0,012). A variação da pressão não foi significativa nem para o Sniff Test, nem para o Toynbee nos dois momentos de avaliação (p≥0,05). A concordância das medidas nos dois diferentes momentos foi de fraca a moderada para os testes nos três grupos de orelhas, e as variâncias da discrepância entre as medidas foram maiores nas orelhas com retrações moderadas/severas. Apesar de não ter atingido significância estatística, o número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. Conclusão: Na população estudada, a média das pressões na cavidade timpânica apresentou uma variação significativa somente durante a Manobra de Valsalva, no primeiro momento de avaliação, nos três grupos de orelhas. As orelhas normais e as com retração leve se comportaram de forma semelhante entre si em todos os testes. As manobras utilizadas apresentaram uma variação intraindividual de fraca a moderada, sendo que maior variação ocorreu em orelhas com retrações moderadas/severas. O número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. / Introduction: The diagnosis of Eustachian tube dysfunctions is essential for better understanding the pathogenesis of chronic otitis media. The literature describes a series of tests to assess tube function; however, there is methodological diversity between them, which varies from application protocols to standardization of tests and their results. Objective: To evaluate the variation in middle ear pressure in patients with tympanic membrane retraction and in normal subjects during tube function tests, as well as to evaluate intra-individual variation between these tests. This study also aimed to evaluate the number of tympanic membrane movements of the contralateral ear during the tests. Methods: An observational contemporary cross-sectional study was conducted, in which the factor under study was the variation in middle ear pressure during tube function tests (Valsalva maneuver, Sniff Test, Toynbee maneuver) in normal subjects and in patients with mild and moderate/severe tympanic retraction. A total of 38 patients (76 ears) were included in the study. Patients underwent tube function tests at two different time points, in order to determine the measure of pressure after each maneuver. During the tests, videotoscopy was performed concomitantly in the contralateral ear, in order to observe tympanic membrane movement. Statistical analysis was performed using SPSS software, version 18.0, considering p values < 0.05 as statistically significant. Results: Mean ± standard deviation for age was 11 ± 2.72 years; 55.3% of patients were male and 44.7% female. The prevalence of type A tympanogram was higher in the groups with normal ears and mild retraction, while type C tympanogram was higher in the group with moderate/severe retraction. An increase in middle ear pressure was observed during Valsalva maneuver at the first time point evaluated in the three groups of ears (p= 0.012). The variation in pressure was not significant either for the Sniff Test or for Toynbee maneuver at the two time points evaluated (p≥0.05). The agreement of the measures at the two different time points was from weak to moderate for the tests in the tree groups of ears, and the variations in discrepancy between measures were higher in ears with moderate/severe retraction. Although it had not reached statistical significance, the number of tympanic membrane movements was higher during the Valsalva maneuver in the tree groups of ears. Conclusion: In this study population, mean pressure in the middle ear showed a significant variation only during the Valsalva maneuver at the first time point evaluated in the three groups of ears. Normal ears and those with mild retraction behaved similarly in all tests. The maneuvers used showed intra-individual variation from weak to moderate, with the higher variation occurring in ears with moderate/severe retraction. The number of tympanic membrane movements was higher during the Valsalva maneuver in the three groups of ears.
29

Angiogênese e metaloproteinases 2 e 9 : estudo comparativo entre colesteatomas adquiridos de pacientes pediátricos e adultos

Dornelles, Cristina de Carvalho January 2008 (has links)
A quantificação da angiogênese e das metaloproteinases pode ser útil na avaliação do comportamento dos colesteatomas, como marcadores de sua agressividade. Objetivo: Comparar os marcadores CD31, MMP2 e MMP9 entre pacientes pediátricos e adultos. Método: transversal. Grupos pediátricos(até 18 anos) e adultos(a partir de 19 anos). Coletados 120 colesteatomas, fixados em formol a 10%, preparadas cinco lâminas, de cada amostra, por técnicas histológicas habituais, observados: número de vasos sangüíneos(CD 31), marcação com MMP2 e MMP9, número de células na matriz e espessura na perimatriz. Dados analisados no SPSS através coeficiente Spearman, exato de Fisher e Mann-Whitney. Resultados: Colesteatomas distribuídos igualmente: 60 pediátricos(11,77±3,57anos); 60 adultos(38,29±14,51anos). CD31pediátrico 7(4 a 11), CD31adulto 4(0 a 10) (P=0,044). MMP2citoplasmática pediátrico 1(0 a 3), MMP2citoplasmática adulto 0(0 a 1) (P=0,006). MMP2nuclear pediátrico 0(0 a 1), MMP2nuclear adulto 0(0 a 1) (P=0,056). MMP9 pediátrico 2(0 a 4), MMP9 adulto 0(0 a 4) (P=0,049). O número de vasos sangüíneos e a quantificação das metaloproteinases estavam fortemente correlacionados com a espessura da perimatriz. Conclusões: Os colesteatomas pediátricos apresentam um grau inflamatório mais exacerbado, produzem mais metaloproteinases, fatores estes, que conjugados, poderiam caracterizar os colesteatomas pediátricos como mais agressivos que os colesteatomas adultos. / Cholesteatoma is an epidermal cyst with three distinct components: matrix, perimatrix and cystic content. The clinical significance of cholesteatoma lies in its association with potential intracranial complications due to bone destruction. Objective: To compare histological and immunohistochemistry analysis between pediatric and adult acquired. Methods: Cross-sectional study. The patients were divided in two groups, according to their age: 60 adults(>18 years old) and 60 children(until 18 years old). The cholesteatomas were fixed in formalin 10%. Five slides from each sample were prepared using standard histology techniques. Slides were analyzed according to average number of blood vessels (CD31), MMP2 and MMP9 positivity and thickness of the perimatrix. Data were analyzed using Mann-Whitney and Fisher's exact tests and Spearmann coeficient, with P values<0.05 considered significant. Results: Perimatrix thickness was 78(34-217); CD31 was 6(0-11), cytoplasmic MMP2 positivity was 0(0-2), nuclear MMP2 positivity was 0(0-1); MMP9 positivity was 2(0-4). Statistical difference, between children and adults, was found in perimatrix thickness(P=0.014); blood vessels(P=0.044); cytoplasmic MMP2(P=0.006), nuclear MMP2(P=0.056); MMP9(P=0.049). Conclusions: Pediatric cholesteatomas have a thicker perimatrix, a greater degree of inflammation, and produce more metalloproteinases than those of adult patients, we can suggest, with the combination of these factors, that cholesteatoma is more aggressive in children than in adults.
30

Estudo da função da tuba de eustáquio em pacientes com retrações da membrana timpânica e em indivíduos normais / Assessment of eustachian tube function in patients with tympanic membrane retraction and in normal subjects

Canali, Inesângela January 2013 (has links)
Introdução: O diagnóstico das disfunções da tuba auditiva é essencial para o melhor entendimento da patogênese da otite média crônica. Estão descritos, na literatura, uma série de testes que avaliam a função tubária, entretanto, entre eles, há uma diversidade metodológica que varia desde os protocolos de aplicação até a padronização dos testes e seus resultados. Objetivo: Avaliar a variação da pressão na orelha média em pacientes com retração da membrana timpânica e em indivíduos normais, durante a realização dos testes de função tubária, bem como avaliar a variação intraindividual desses testes. Este estudo também tem por objetivo avaliar o número de movimentações da membrana timpânica na orelha contralateral, durante a realização dos testes. Métodos: Estudo observacional do tipo transversal e contemporâneo, onde o fator em estudo foi a variação de pressão na orelha média, durante a realização dos testes de função tubária (Manobra de Valsalva, Sniff Test, Manobra de Toynbee) em indivíduos normais e em pacientes com retrações timpânicas leves e moderadas/severas. Foram incluídos 38 pacientes, totalizando 76 orelhas. Os pacientes foram submetidos, em dois momentos diferentes, aos testes de função tubária para determinar a medida da pressão após cada manobra. Durante a realização dos testes, videotoscopia era realizada concomitantemente na outra orelha, a fim de se observar a movimentação da membrana timpânica. A análise estatística foi realizada por meio do programa SPSS versão 18.0, em que foram considerados como estatisticamente significativos os valores de p< 0,05. Resultados: A média ± desvio-padrão da idade foi de 11 ± 2,72 anos; 55,3% dos pacientes foram do sexo masculino e 44,7% do sexo feminino. A prevalência de curva A foi maior nos grupos de orelhas normais e retrações leves, enquanto que de curva C foi maior no grupo de retrações moderadas/severas. Observamos aumento das pressões na orelha média durante a realização da Manobra de Valsalva no primeiro momento de avaliação nos três grupos de orelhas (p= 0,012). A variação da pressão não foi significativa nem para o Sniff Test, nem para o Toynbee nos dois momentos de avaliação (p≥0,05). A concordância das medidas nos dois diferentes momentos foi de fraca a moderada para os testes nos três grupos de orelhas, e as variâncias da discrepância entre as medidas foram maiores nas orelhas com retrações moderadas/severas. Apesar de não ter atingido significância estatística, o número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. Conclusão: Na população estudada, a média das pressões na cavidade timpânica apresentou uma variação significativa somente durante a Manobra de Valsalva, no primeiro momento de avaliação, nos três grupos de orelhas. As orelhas normais e as com retração leve se comportaram de forma semelhante entre si em todos os testes. As manobras utilizadas apresentaram uma variação intraindividual de fraca a moderada, sendo que maior variação ocorreu em orelhas com retrações moderadas/severas. O número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. / Introduction: The diagnosis of Eustachian tube dysfunctions is essential for better understanding the pathogenesis of chronic otitis media. The literature describes a series of tests to assess tube function; however, there is methodological diversity between them, which varies from application protocols to standardization of tests and their results. Objective: To evaluate the variation in middle ear pressure in patients with tympanic membrane retraction and in normal subjects during tube function tests, as well as to evaluate intra-individual variation between these tests. This study also aimed to evaluate the number of tympanic membrane movements of the contralateral ear during the tests. Methods: An observational contemporary cross-sectional study was conducted, in which the factor under study was the variation in middle ear pressure during tube function tests (Valsalva maneuver, Sniff Test, Toynbee maneuver) in normal subjects and in patients with mild and moderate/severe tympanic retraction. A total of 38 patients (76 ears) were included in the study. Patients underwent tube function tests at two different time points, in order to determine the measure of pressure after each maneuver. During the tests, videotoscopy was performed concomitantly in the contralateral ear, in order to observe tympanic membrane movement. Statistical analysis was performed using SPSS software, version 18.0, considering p values < 0.05 as statistically significant. Results: Mean ± standard deviation for age was 11 ± 2.72 years; 55.3% of patients were male and 44.7% female. The prevalence of type A tympanogram was higher in the groups with normal ears and mild retraction, while type C tympanogram was higher in the group with moderate/severe retraction. An increase in middle ear pressure was observed during Valsalva maneuver at the first time point evaluated in the three groups of ears (p= 0.012). The variation in pressure was not significant either for the Sniff Test or for Toynbee maneuver at the two time points evaluated (p≥0.05). The agreement of the measures at the two different time points was from weak to moderate for the tests in the tree groups of ears, and the variations in discrepancy between measures were higher in ears with moderate/severe retraction. Although it had not reached statistical significance, the number of tympanic membrane movements was higher during the Valsalva maneuver in the tree groups of ears. Conclusion: In this study population, mean pressure in the middle ear showed a significant variation only during the Valsalva maneuver at the first time point evaluated in the three groups of ears. Normal ears and those with mild retraction behaved similarly in all tests. The maneuvers used showed intra-individual variation from weak to moderate, with the higher variation occurring in ears with moderate/severe retraction. The number of tympanic membrane movements was higher during the Valsalva maneuver in the three groups of ears.

Page generated in 0.039 seconds