• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 287
  • 265
  • 38
  • 10
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 673
  • 255
  • 143
  • 127
  • 125
  • 118
  • 117
  • 95
  • 84
  • 79
  • 61
  • 58
  • 58
  • 56
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
551

A cone-beam computerized tomography evaluation of anterior root resorption comparing SureSmile® and conventional edgewise treatments

Patel, Neepa. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 120-128.
552

Changes in arch dimensions after extraction and non-extraction orthodontic treatment.

MacKriel, Earl Ari. January 2008 (has links)
<p>The aim of this study was to determine whether there are changes in the interdental arch widths and arch lengths of the mandibular and maxillary arches during nonextraction and extraction orthodontic treatment. The records of 78 patients treated by one orthodontist were used for this study. Three treatment groups were selected: a nonextraction group (Group NE), a group treated with extraction of maxillary and mandibular first premolars (Group 44), and a group treated with extraction of maxillary first premolars and mandibular second premolars (Group 45). The arch width measurements were measured in the inter-canine, inter-premolar and inter-molar areas. The arch length was measured as the sum of the left and right distances from mesial anatomic contact points of the first permanent molars to the contact point of the central incisors or to the midpoint between the central incisor contacts, if spaced.</p> <p>Statistical analysis included descriptive statistics of the data, analysis of the correlation matrices, Wilcoxon Signed Rank tests and Kruskal-Wallis tests of the changes which occurred during treatment. The intercanine widths in the mandible and maxilla increased during treatment in all three groups, with the extraction groups showing a greater increase than Group NE (p&lt / 0.05). In Group NE the mandibular arch length increased (p&lt / 0.05), while the maxillary arch length remained essentially unchanged. Both extraction groups showed decreases in arch length in the dentitions (p&lt / 0.05), with greater decreases occurring in the maxilla. The difference in arch length change between the two extraction groups was not significant (p&gt / 0.10). The inter-canine arch width increased in all three treatment groups, more so in the two extraction groups. From this it is evident that extraction treatment does not necessarily lead to narrowing of the dental arches in the canine region. The inter-second premolar arch width decreased in both extraction groups. Non-extraction treatment resulted in an increase in the inter-premolar and inter-molar arch widths.</p>
553

Danties pulpos atsako į ortodontnio gydymo metu veikiančias jėgas tyrimai / Analysis of the selected parameters of dental pulp response to application of orthodontic load

Vėberienė, Rita 09 March 2011 (has links)
Darbo tikslas yra nustatyti galimus metabolinius pokyčius žmogaus danties pulpoje ortodontinio gydymo metu veikiant gramzdinimo jėgoms ir įvertinti šių jėgų įtaką pulpos gyvybingumui. Uždaviniai: 1. Nustatyti fermento aspartato aminotransferazės (toliau – AST) akty¬vumą sveikų dantų pulpos audinyje. 2. Nustatyti, kaip kinta danties pulpos AST aktyvumas veikiant dantis 7 ir 14 dienų nepertraukiama gramzdinimo jėga ir 7 dienų nepertrau¬kiama jėga su vėlesniu 7 dienų poilsiu bei palyginti šiuos aktyvumus su sveikų dantų pulpos AST fermento aktyvumu. 3. Įvertinti danties pulpos atsaką į dirginimą elektros srove, taikant elektroodontometrinio gyvybingumo testą (toliau – EPT) sveikiems ir dantims paveiktiems 7 ir 14 dienų nepertraukiama gramzdinimo jėga bei 7 dienų nepertraukiama jėga su vėlesniu 7 dienų poilsiu. 4. Atlikti jėgos, veikiančios ortodontinio krūvio metu, matematinę ana¬lizę. 5. Įvertinti galimą pulpos AST fermento aktyvumo bei pulpos EPT at¬sako ryšį su gramzdinimo jėgos dydžiu, dantų šaknų skaičiumi, žan¬dikaulio tipu, bei amžiumi. 6. Atlikti pacientų, kuriems radiografinis tyrimas taikytas odontolo¬ginio gydymo planavimui, skaitmeninių panoraminių radiogramų analizę, siekiant įvertinti pulpos akmenų pulpos kameroje ir šak¬ninėje pul¬poje paplitimą tarp jauno amžiaus pacientų. 7. Atlikti ortodontinių pacientų pirminių bei galutinių skaitmeninių pa¬no¬raminių radiogramų lyginamąją analizę, siekiant įvertinti pulpos akmenų paplitimą pulpos kameroje ir šakninėje... [toliau žr. visą tekstą] / The aim of the study was to evaluate metabolic alterations of the human dental pulp in response to application of intrusive forces, and to investigate impact of such forces on the pulp vitality.Objectives of the study: 1) to determine activity of aspartate aminotransferase (hereinafter – AST) in the dental pulp of teeth unaffected by orthodontic loading; 2) to evaluate changes in the dental pulp AST activity after appli¬cation of continuous intrusive force for 7 and for 14 days, or, continuous force for 7 days with the following 7 days of rest, and to compare the obtained values with the pulp AST activity in teeth unaffected by orthodontic loading; 3) to compare dental pulp response to electrical stimulation by means of electric odontometric pulp test (hereinafter – EPT) in teeth unaffected by orthodontic loading, and in teeth subjected to continuous intrusive force for 7 and for 14 days, also for 7 days of continuous loading with the following 7 days of rest; 4) to perform mathematical analysis of the forces acting during the orthodontic loading; 5) to analyse relation of the pulp AST activity and the EPT measu¬rements with the intrusive force magnitude, tooth type (i.e. number of tooth roots; maxilar or, mandibular), and patient‘s age; 6) to analyse digital panoramic X-ray images of the patients, sub¬jected to radiography during routine dental treatment planning, in order to observe occurence of pulp stones in the dental pulp chamber; 7) to compare baseline and final... [to full text]
554

A comparison of treatment and posttreatment results in four first premolar extraction cases : tweed standard edgewise vs. the preadjusted appliance /

Nowlin, Ryan Van. January 2003 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 101-105.
555

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd /

Penido, Sérgio Milton Martins de Oliveira. January 2006 (has links)
Orientador: Ary dos Santos-Pinto / Banca: Vânia Célia Vieira de Siqueira / Banca: Rodrigo de Castro Albuquerque / Banca: Lídia Parsekian Martins / Banca: Luiz Gonzaga Gandini Júnior / Resumo: Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / Abstract: This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure. / Doutor
556

Avaliação do tratamento ortodôntico precoce da classe II, 1ª divisão, subdivisão /

Grehs, Renésio Armindo. January 2004 (has links)
Orientador: Tatsuko Sakima / Banca: Ary dos Santos Pinto / Banca: Darcy Flávio Nouer / Banca: Maria Beatriz Borges de Araújo Magnani / Banca: Dirceu Barnabé Raveli / Resumo: Esta pesquisa de natureza prospectiva foi realizada com base numa amostra não casualizada constituída de 23 indivíduos portadores de má oclusão Classe II, 1ª Divisão, Subdivisão na fase da dentadura mista. O propósito do estudo foi avaliar um novo procedimento para o tratamento precoce da Classe II Subdivisão com envolvimento mandibular, método proposto por Sakima 85 em 2003. A amostra foi dividida em: Grupo 1 - Portadores de má oclusão Classe II Subdivisão com mordida cruzada posterior unilateral (D) ou (E) e Grupo 2 - Portadores de má oclusão Classe II Subdivisão sem cruzamento. Todos os indivíduos foram submetidos a tratamento ortodôntico de interceptação para correção da subdivisão, sendo que o Grupo 1 teve procedimento prévio para descruzamento da mordida cruzada posterior unilateral (MCPU). A avaliação dos resultados foi realizada mediante tomada de radiografias extra-orais Submento-vertex, os cefalogramas foram traçados e os dados compilados para análise em computador. Os traçados cefalométricos obtidos das imagens radiográficas da Submento-vertex (SMV) foram digitalizados no programa Radiocef. Os dados analisados, submetidos à metodologia estatística e os resultados discutidos. O método estatístico empregado, além da utilização da média e desvio padrão, contou com o Teste "t" de Student, Teste F de Snedecor e probabilidade "p", utilizou-se também o teste não paramétrico de Mann-Whitney-Wilcoxon, os dados estatísticos foram utilizados para avaliar os resultados do tratamento ortodôntico realizado. Após a discussão dos resultados, concluiu-se que: 1)Houve presença de rotação mandibular significante para ambos os grupos estudados quando relacionada maxila e mandíbula; 2) A evolução dos grupos estudados foi semelhante tanto clínica como cefalométrica; 3) Os movimentos dentários constatados melhoram o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to evaluate a new approach to the early orthodontic treatment of Class II, division 1, subdivision, in the mixed dentition and determined the utility of approach. The sample consisted of 23 subjects divided in two groups (group 1 and group 2). The average was 9.3 years considered in both groups. Measurements were obtained with the use of Submento-vertex Cephalometric Radiographs. The Submento-vertex Radiographs symmetry was assessed by measuring the differences in the spatial positions of dental and Skeletal landmarks between right and left side, determined asymmetric (A) and normal (N) sides. The Angle's 2 Class II subdivision was evaluated in the mixed dentition. Statistic method was based on the skewness statistics, the distributions were normal, allowing means and standard deviations to be used to describe central tendencies and dispersion. We also used the Student t test, the Snedecor p test and Mann-Whitney-Wilcoxon tests were used to statistically comparation.The results showed lower jaw replacement and dento-alveolar displacement in order to correct this malocclusion. The conclusions about the present study were: 1) There was significant mandibular rotation from the asymmetric side to the symmetric side in the two groups when maxilar and mandibular relation was investigated; 2) The two groups evolution was clinical and cephalometrical similar; 3) The teeth movements provide evidence to better relation of the occlusion; 4) The midline line of the teeth has a clinically consistent to normalization and this can better investigated with other evaluation methods. / Doutor
557

Efeito da corticotomia e decorticalização na movimentação ortodôntica: estudo em ratos / Corticotomy and Decortication effect on orthodontic tooth movement: study in rats

Zuppardo, Marcelo Lelis 06 June 2018 (has links)
Submitted by MARCELO LELIS ZUPPARDO (ortodontiazuppardo@hotmail.com) on 2018-08-01T23:43:51Z No. of bitstreams: 1 Versão FINAL 01.08.2018.pdf: 1738428 bytes, checksum: ea89ecbcd914fe55c572f405cd81df64 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-08-03T12:52:56Z (GMT) No. of bitstreams: 1 zuppardo_ml_dr_sjc.pdf: 1738428 bytes, checksum: ea89ecbcd914fe55c572f405cd81df64 (MD5) / Made available in DSpace on 2018-08-03T12:52:56Z (GMT). No. of bitstreams: 1 zuppardo_ml_dr_sjc.pdf: 1738428 bytes, checksum: ea89ecbcd914fe55c572f405cd81df64 (MD5) Previous issue date: 2018-06-06 / Este estudo comparou dois protocolos cirúrgicos, corticotomia e corticotomia com decorticalização, em ratos para verificar alteração na movimentação ortodôntica convencional. 60 animais foram divididos aleatoriamente: Grupo controle (GC) - movimentação ortodôntica convencional; Grupo 1 (G1) -movimentação ortodôntica e corticotomia; Grupo 2 (G2) - movimentação ortodôntica com corticotomia e decorticalização. Os animais foram eutanasiados após 7 e 14 dias. No G1 e G2 houve uma maior movimentação ortodôntica comparado aos animais do GC aos 14 dias (p = 0,009 e 0,016) com uma maior área radiográfica interradicular, menor volume ósseo/volume total, menor área final e menor porcentagem de osso. Aos 7 dias os animais do G2 apresentaram menor volume de osso/volume total comparado com GC e aos 14 dias os animais do G2 apresentaram uma menor medida linear da crista óssea comparado com o GC. Os animais do GC aos 14 dias apresentaram uma maior área final comparado aos 7 dias, enquanto o G2 apresentou maior número de células TRAP positivas tanto aos 7 quanto aos 14 dias comparado com o G1. Na análise histológica aos 7 dias houve frequente reabsorção radicular inicial geralmente associada às áreas de hialinização e aos 14 dias, presença do infiltrado inflamatório e com menor ocorrência de áreas hialinas. O padrão de reabsorção radicular iniciado no 7º dia de movimento e consolidado no 14º dia. Concluímos que a corticotomia acelera a movimentação ortodôntica em 14 dias independente da magnitude da injúria cirúrgica / This study compared two surgical protocols, corticotomy and decorticalization corticotomy, in rats to verify alteration in conventional orthodontic movement. 60 animals were randomly divided: Group 1 (G1) orthodontic movement and corticotomy, and Group 2 (G2) orthodontic movement with corticotomy and decorticalization. The animals were euthanized after 7 and 14 days. In G1 and G2, there was a greater orthodontic movement compared to CG animals at 14 days (p = 0.009 and 0.016) with a higher interradicular radiographic area, lower bone volume / total volume, lower final area and lower percentage of bone. At 7 days the G2 animals presented lower bone volume / total volume compared to CG and at 14 days G2 animals presented a smaller linear measure of bone crest compared to CG. GC animals at 14 days presented a larger final area compared to 7 days, while G2 presented a higher number of TRAP cells positive at 7 and 14 days compared to G1. In the histological analysis at 7 days, there was frequent initial root resorption generally associated with hyalinization areas and at 14 days, presence of inflammatory infiltrate and less occurrence of hyaline areas. The root resorption pattern started on day 7 of movement and was consolidated on the 14th day. We conclude that corticotomy accelerates orthodontic movement in 14 days regardless of the magnitude of the surgical injury.
558

Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos / Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study

Rodrigues, Kelly Regina Thomé Portugal 04 October 2011 (has links)
Made available in DSpace on 2016-08-03T16:30:57Z (GMT). No. of bitstreams: 1 RESUMO - Kelly Portugal Rodrigues.pdf: 90584 bytes, checksum: a9009d09309f76e094fc03b33ceabe30 (MD5) Previous issue date: 2011-10-04 / The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement. / O presente estudo visou comparar in vitro o atrito produzido por braquetes convencionais metálicos e estéticos com canaleta metálica e vítrea quando inseridos fios de secções redonda e retangular de diferentes dimensões, simulando situações sem deslocamento, com deslocamento de 2 mm e com simulação do efeito binding 3º. Foram utilizados 125 braquetes de 5 marcas comerciais (Roth Standard, Composite, Elation, Invu e Radiance), sendo 25 braquetes para cada corpo de prova. Para os ensaios laboratoriais, foram colados 5 braquetes simulando uma hemi-arcada superior direita (incisivos central e lateral, canino, primeiro e segundo premolares) em um dispositivo para posicionamento dos braquetes, sendo este acoplado à máquina universal de ensaios EMIC DL2000. Foram empregados os fios 0,016 , 0,018 e 0,017 x 0,025 NiTi para realização dos ensaios sem deslocamento e com deslocamento de 2 mm e os fios de secção 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x 0,025 CrNi para realização dos ensaios com angulação zero grau e 3º. Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a Análise de Variância e o teste de Tukey (p<0,05). Os resultados demonstraram que nos ensaios sem deslocamento o braquete estético de policarbonato Composite apresentou menor atrito em todos os fios avaliados, enquanto o maior atrito em todas as combinações realizadas foi observado no braquete estético cerâmico monocristalino Radiance em relação aos demais braquetes. Nos ensaios com deslocamento de 2 mm e simulação do efeito binding 3º, os resultados foram semelhantes aos observados nos ensaios sem deslocamento. Contudo, houve uma diferença estatisticamente significante entre os cinco corpos de prova, sendo o atrito verificado, respectivamente e de forma crescente, nos braquetes Composite, Roth Standard, Elation, Invu e Radiance. Pôde-se concluir que a resistência friccional teve influência da composição dos braquetes, diâmetro dos fios e tipo de ensaio realizado (deslocamento de 2 mm e angulação de 3º). Além disso, a inserção da canaleta metálica no braquete estético de policarbonato Elation reduziu de forma estatisticamente significante o atrito, porém esse foi maior do que o gerado por um braquete convencional metálico e, por fim, a incorporação da canaleta vítrea no braquete estético cerâmico policristalino Invu ofereceu uma maior lisura de superfície, reduzindo as irregularidades e imperfeições presentes na canaleta o que levou, consequentemente, a uma redução estatisticamente significante no atrito, o que demonstra que a modificação em sua canaleta favoreceu o deslocamento e reduziu de forma efetiva essa resistência à fricção.
559

Avaliação dos torques para inserção, remoção e fratura de diferentes miniimplantes ortodônticos em cortical de tíbia bovina / Evaluation of the insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

Maria Fernanda Prates da Nova 22 February 2008 (has links)
A utilização de grupos de dentes ou de aparelhos dependentes de cooperação, como mecanismos de ancoragem, podem ser fatores limitantes para o sucesso de terapias ortodônticas. Tal fato incentivou a busca de métodos para ancoragem esquelética ou absoluta, que incluem os miniimplantes ortodônticos. Comercialmente estão disponíveis em diversas dimensões e desenhos, porém existem poucas informações sobre a relação de sua morfologia com falhas clínicas ou fraturas. O objetivo deste trabalho foi avaliar o comportamento de miniimplantes com formas diferentes para os seguintes fatores: (a) torque máximo de inserção, (b) torque máximo de remoção, (c) torque de fratura, (d) tipo de fratura, (e) tensão cisalhante e tensão normal. Foram utilizados 20 miniimplantes autoperfurantes, 10 da marca SIN e 10 da Neodent, com 1,6 mm diâmetro e com 8 e 7 mm de comprimento, respectivamente. Destes 10 miniimplantes, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando assim 4 grupos: SIN sem perfil (SSP), SIN com perfil (SCP), Neodent sem perfil (NSP) e Neodent com perfil (NCP). Todos os miniimplantes foram inseridos em cortical de tíbia bovina e depois removidos com micro-motor acoplado a um torquímetro digital que registrou os torques máximos de inserção e de remoção. Os miniimplantes que não fraturaram durante os ensaios de inserção e remoção foram submetidos ao ensaio de fratura realizado em máquina universal de ensaios Emic. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas foram comparados entre todos os grupos. O tipo de fratura foi avaliado pela tensão cisalhante e por avaliação em microscópio eletrônico de varredura (MEV). Para cada grupo comparou-se os torques de inserção e de remoção. Todas as comparações foram feitas através da ANOVA. Verificou-se que o grupo NCP apresentou torque máximo de inserção significativamente maior que os demais grupos (30,6 1,8 Ncm), porém todos fraturaram durante os ensaios de inserção (n=2) ou de remoção (n=3). Não houve diferença significativa entre os grupos para o torque de remoção. Apenas o grupo SSP apresentou diferença significativa entre os torques de inserção e de remoção, para o mesmo grupo. Para o grupo NSP o torque de fratura foi significativamente menor do que todos os outros grupos (27,42 1,14 Ncm). Não houve diferença significativa entre as tensões cisalhante e normal entre os grupos, demonstrando que todos os miniimplantes sofreram fratura do tipo dúctil, confirmado através do MEV. Uma vez que os miniimplantes de todos os grupos são confeccionados com a mesma liga metálica, variando apenas na forma, conclui-se que a resistência à fratura pode ser afetada por esta variável. / The use of groups of teeth or appliances which rely on patient compliance, as anchorage mechanisms, can be limiting factors for the success of orthodontic treatment. This fact encouraged the search for skeletal or absolute anchorage methods, which include orthodontic mini-implants. They are commercially available in different dimensions and designs, but there is scarce information regarding the relation between its morphology and clinical failures or fractures. The purpose of this study was to evaluate the behavior of mini-implants with different forms for the following factors: (a) maximum insertion torque, (b) maximum removal torque, (c) fracture torque, (d) type of fracture, (e) shear tension and (f) normal tension. Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6 mm in diameter and with 8 and 7 mm in length, respectively. Out of these 10 mini-implants, 5 did not have a neck and the other 5 had a 2 mm neck, and were separated into 4 groups: SIN without neck (SSP), SIN with neck (SCP), Neodent without neck (NSP) and Neodent with neck (NCP). All mini-implants were inserted in bovine tibia cortex and later removed with a low speed handpiece connected to a digital torquimeter, which recorded the maximum insertion and removal torques. The mini-implants that did not fracture during insertion and removal assays were submitted to the fracture test, performed in an EMIC universal test machine. The insertion, removal and fracture torques, as well as the calculated shear and normal tensions were compared between all groups. The type of fracture was assessed by the shear tension and by evaluation in scanning electronic microscope (SEM). Insertion and removal torques were compared for each group. All comparisons were done by ANOVA. The NCP group presented a significantly greater insertion torque than all other groups (30.6 1.8 Ncm), but all of them fractured during insertion (n=2) or removal (n=3). There were no significant differences between groups for removal torque. Only group SSP presented a significant difference between insertion and removal torques, for the same group. For group NSP, the fracture torque was significantly smaller than all other groups (27.42 1.14 Ncm). There was no significant difference between shear and normal tensions between groups, demonstrating that all mini-implants suffered ductile fracture, confirmed by SEM. Since mini-implants from all groups are made of the same alloy, varying only in form, one may conclude that resistance to fracture can be affected by this variable.
560

Avaliação de escova ultrassônica em pacientes sob terapia ortodôntica. Estudo in vitro, clínico e microbiológico

Costa, Mauricio Ribeiro [UNESP] 06 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-06Bitstream added on 2014-06-13T18:45:14Z : No. of bitstreams: 1 costa_mr_dr_arafo.pdf: 1446612 bytes, checksum: 025bbf3e00577588cbd095875d456697 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar o efeito de uma escova ultrassônica, comparada a uma elétrica e a uma manual, sobre os parâmetros clínicos periodontais e microbiológicos de adolescentes sob terapia ortodôntica com aparelhos fixos. Paralelamente, foi avaliada a diminuição da força adesiva de braquetes ortodônticos, fixados a dentes humanos extraídos, após o uso de uma escova dentária ultrassônica comparada a uma escova elétrica. Material e Método: Para o experimento in vivo, 21 indivíduos (15,2l1,7) que utilizavam aparelhos fixos há mais de um ano foram divididos em três grupos de acordo com a seqüência de uso das escovas (crossover). Os pacientes usaram cada escova por um período de 30 dias, com intervalos de 15 dias entre as mesmas (washout). Amostras de saliva e placa bacteriana foram coletadas para realização de cultura microbiológica de Streptococcus grupo mutans e técnica de Checkerboard DNA-DNA Hybridization, respectivamente. No experimento in vitro, braquetes ortodônticos foram colados a superfície mais plana de quarenta e cinco dentes humanos extraídos. Posteriormente, os corpos de prova foram divididos em grupos de acordo com a escova a ser utilizada. Após o procedimento de escovação, a resistência adesiva foi avaliada em uma maquina de ensaios mecânicos. Resultado: Uma diferença significante no índice de placa (p<0,05) foi observada após o uso de escova ultrassônica nas superfícies vestibulares (10,32% pré e 3,96% pós-escovação). Da mesma forma, após o uso das escovas ultrassônicas e elétricas, as contagens de Streptococcus grupo mutans diminuíram significativamente (técnica de cultura microbiana - p<0,05). A técnica Checkerboard DNA-DNA hybridization apontou uma redução nos níveis de T. forsythia após o uso da escova elétrica e das espécies S. noxia, S. sanguinis... / This study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of bacteria in relation to an electric and a manual toothbrush. In addition, it was evaluated the effect of brushing with both an ultrasonic and electric toothbrush on the bond strength of orthodontic brackets bonded to extracted human teeth. Material and method: Twenty-one patients (mean 15.2l1.7 years) with orthodontic appliances were randomly divided into three groups according to the sequence of brush usage (crossover study). The subjects used each assigned brush for a period of 30 days, followed by an interval of 15 days (washout) during which they returned to their regular toothbrushes and dental floss used in accordance with the monthly instructions of the orthodontist given prior to the study. During each visit, participants received a periodontal evaluation and samples of saliva and subgingival plaque were collected for microbiological tests (Streptococcus mutans culture and DNA-DNA Checkerboard Hybridization). For in vitro evaluation, individual orthodontic brackets were bonded to the smoothest surface of forty-five teeth. The test specimens were randomly distributed into three groups according to the toothbrush to be used. After completing the brushing stage, the test specimens were taken to the mechanical assay machine for a shearing test. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (10.32% against 3.96%). The counts of S. mutans decreased in the electric and ultrasonic groups (culture test - p<0.05). The DNA-DNA Checkerboard hybridization technique showed that the counts of T. forsythia decreased significantly after a month of electric brush usage. Furthermore, in the manual group, S. noxia, S. sanguinis and P. melaninogenica counts also decreased... (Complete abstract, click electronic access below)

Page generated in 0.1326 seconds