• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito de três sistemas de osteotomia - ultrassom cirúrgico, laser Er, Cr: YSGG e sistema rotatório - sobre o processo de osseointegração e reparo de defeitos ósseos em tíbia de ratos : estudo histomorfométrico, imuno-histoquímico e biomecânico /

Esteves, Jônatas Caldeira. January 2014 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Roberto Poi / Banca: Thalita Pereira Queiroz / Banca: Paulo Tambasco de Oliveira / Resumo: O objetivo deste trabalho foi avaliar o processo de reparo ósseo e a osseointegração de implantes inseridos em leitos cirúrgicos preparados por meio de Brocas Convencionais, Ultrassom Piezoelétrico e LASER Er,Cr:YSGG. Como objetivo secundário, foi testada a habilidade do ultrassom cirúrgico de estumilar a liberação de citocinas e fatores de crescimento ósseo durante o processo de reparo. Para tanto, dois estudos distintos foram conduzidos. No Estudo 1, 144 ratos foram divididos em 3 grupos (Grupos Broca, LASER e Piezo) com 48 animais cada. Mini implantes usinados foram instalados em ambas as tíbias de cada animal em alvéolos cirúrgicos preparados pelos 3 sistemas testados de acordo com o grupo ao qual o animal pertencia Após a intervenção cirúrgica, 8 animais por grupo foram sacrificados aos 0, 3, 7, 14, 30 e 60 dias pós-operatórios.. O implante da tíbia direita foi utilizado para o ensaio de torque de remoção e o da tíbia esquerda, para análise de Contato-Osso-Implante (COI) e Fração de Área Ocupada por Osso (FAOO). No Estudo 2, 174 animais foram divididos nos mesmos grupos experimentais - Broca, Piezo e Laser - com 63, 63 e 48 animais cada, respectivamente. Defeitos ósseos de 2mm de diâmetro foram produzidos na tíbia direita dos animais usando um dos três dispositivos testados de acordo com o grupo ao qual o animal foi designado. Oito animais de cada grupo foram sacrificados aos 0, 3, 7, 14 30 e 60 dias e a cicatrização óssea foi analisada por histomorfometria e detecção imuno-histoquímica de Osteocalcina, Osteoprotegerina, Rankl, Vegf e Caspase-3. Cinco animais dos Grupos Broca e Piezo foram sacrificados aos 3, 7 e 14 dias e o espécimes coletados foram utilizados para análise de PCR quantitativo (Q-PCR). Os resultados do Estudo 1 demonstraram a osseointegração dos implantes no três grupos estudados. No Grupo Broca a formação óssea ocorreu mais precocemente, porém um aumento significativo no... / Abstract: The aim of this study was to evaluate the bone healing process and osseointegration of implants placed in sockets prepared by conventional Drills, Piezosurgery and Er,Cr:YSGG laser. As a secondary objective we tested the hability of Piezosurgery of enhancing the bone repair by releasing of citokynes and growth factor. Therefore, two different studies were conducted. In study 1, 144 rats were assigned to 3 groups: Groups Drill, Laser and Piezo, with 48 animals in each group. Machined mini-implants were placed in both tibiae of each animal in sockets prepared by the three tested systems, according to the group in which it was assigned. After the surgical procedures, 8 animals were sacrificed postoperatively at 0, 3, 7, 14, 30 and 60 days in each group. The implant of the right tibia was used for removal torque test and the left tibia implant was used for Bone-to-Implant Contact (BIC) and Bone Area Fraction Occupancy (BAFO) analysis. In Study 2, 174 animals were ssigned to the same experimental Goups - Drill, Piezo and Laser - with 63, 63 and 48 animals in each group. Bone defects with 2mm in diameter were created in the righ tibia of each animal using one of the three tested devices according to the group in which it was assigned. Eight animals of each group was sacrificed at 0, 3, 7, 14 , 30 and 60 days and bone healing were analyzed by means of histomorphometry and immunohistochemical detection of Osteocalcin, Osteoprotegerin, Rankl, Vegf and Caspase-3. Also, 5 animals form Gorups Drill and Piezo were sacrificed at 3, 7 and 14 days and the bone samples were used for quantitative PCR (Q-PCR) analysis. Results of Study 1 demonstrated implant osseointegration in all experimental groups. The Group Drill presented early bone formation, however, significant increasing in torque removal values occurred only at 30 days. In Groups Laser and Piezo, removal torque increased early and bone healing around the implant was progressively increased until... / Doutor
22

Efeito na osseointegração de um novo método de nanotexturização de superfície de implantes através de anodização /

Villaça-Carvalho, Maria Fernanda Lima. January 2016 (has links)
Orientador: Mari Eli Leonelli de Moraes / Co-orientador: Luana Marotta Reis de Vasconcellos / Banca: João Paulo Barros Machado / Banca: Natal Nerímio Regone / Banca: Maria Aparecida Neves Jardini / Banca: Sergio Lucio Pereira de Castro Lopes / Resumo: A Implantodontia é uma das áreas da Odontologia que mais tem evoluído nas últimas décadas. Diversos estudos são desenvolvidos na intenção de otimizar o processo de osseointegração utilizando a nanotopografia na superfície dos implantes. Atualmente o processo de anodização da superfície vem se destacando entre estas técnicas. Desta forma, o objetivo nesta pesquisa foi obter nano rugosidades e fase de anatase em implantes odontológicos de Titânio, buscando a otimização da osseointegração. Sessenta implantes foram caracterizados quanto à morfologia, por meio de microscopia de força atômica (AFM) e Microscopia Eletrônica de Varredura (MEV); quanto à composição química, por análise por detector de espectrometria por espalhamento de energia (EDS) e Espectroscopia Raman; e por fim, quanto ao potencial de corrosão, pela análise de impedância eletroquímica (EIE). A osteogênese, in vivo, foi comparada por Radiografia periapical (RP), Microtomografia Computadorizada (µTC) e teste de remoção por torque reverso; e, a análise in vitro, foi realizada por teste de citotoxicidade por MTT [(brometo de 3-4,5-dimetiltiazol-2-il)-2,5-difeniltetrazoliol]. Os implantes foram divididos em: G1 (controle); Grupo 2 (jateado); Grupo 3 (anodizadoexperimental). Cada coelho recebeu um implante de cada grupo nas tíbias direita e esquerda, e cinco coelhos, foram eutanasiados 2 e 6 semanas após a cirurgia. Os implantes da tíbia direita foram submetidos à RP e à µTC; e os da tíbia esquerda, ao teste de torque reverso e análise de citotoxicidade por MTT. AFM e MEV comprovaram a presença de nano rugosidades na superfície em G3; análises de EDS e Espectroscopia Raman, demonstraram aumento da camada do filme de TiO2 e a obtenção de anatase em G3. Na RP, nenhum implante apresentou halo radiolúcido. Na µTC, G3 foi sempre superior aos demais grupos nos parâmetros observados: BV, BV/TV, Tb.Th. No teste de torque reverso, houve... / Abstract: The Implantology is one of the areas of dentistry that has most evolved in recent decades. Many studies have been developed with the intention of optimizing the osseointegration process using nanotopography on the surface of the implants. Currently the surface of the anodizing process has stood out among these techniques. Thus, the aim of this research was to obtain nano roughness and anatase phase in dental Titanium implants, seeking for the optimization of the osseointegration. Sixty implants were characterized for morphology by atomic force microscopy (AFM) and Scanning Electron Microscopy (SEM); in chemical composition, by mass spectrometry detector energy scattering (EDS) and Raman spectroscopy; and finally, as the potential for corrosion, the electrochemical impedance analysis (EIS). Osteogenesis in vivo was compared by Periapical Radiography (PR), Computed Microtomography (μTC), removal reverse torque test; and in vitro analysis, it was performed by MTT cytotoxicity assay [(bromide 3-4,5-dimethylthiazol-2-yl) -2,5-difeniltetrazoliol]. The implants were divided into G1 (control); Group 2 (sandblasted); Group 3 (anodized-experimental). Each rabbit received an implant of each group in the right and left tibias and five rabbits were euthanized 2 and 6 weeks after surgery. The implants of the right tibia underwent PR and μTC; and the left tibia, the reverse torque test and MTT cytotoxicity assay. AFM and SEM confirmed the presence of nano roughness on the surface in G3; EDS analysis and Raman spectroscopy showed increased TiO2 film layer and obtainment of anatase G3. In PR, no implant presented radiolucent halo. In μTC, G3 has always been higher than the other groups in the observed parameters: BV, BV / TV, Tb.Th. In the reverse torque test, It was required greater removal force of anodized implants. In the MTT test, the experimental implants were nontoxic to cells. It was conclude that the anodizing process used in this study... / Doutor
23

Avaliação da osseointegração de uma superfície hidrofílica em osso do tipo IV : estudo pré-clínico em ilíacos de coelhos /

Pinto, Gustavo Da Col dos Santos January 2019 (has links)
Orientador: Elcio Marcantonio Jr / Resumo: O objetivo desse estudo foi avaliar a osseointegração de uma superfície hidrofílica (Jateamento + ataque ácido + imersão em solução isotônica) em comparação a uma superfície hidrofóbica (Jateamento + ataque ácido), utilizando um modelo experimental de osso tipo IV, obtido através da instalação de implantes de titânio no osso ilíaco de coelhos. Para realização do estudo, 24 animais foram submetidos a instalação de 4 implantes no osso ilíaco bilateralmente, sendo 2 implantes com superfície hidrofóbica e dois implantes com superfície hidrofílica. Os coelhos foram submetidos à eutanásia nos períodos de 2, 4 e 8 semanas após a instalação dos implantes. Após a eutanásia, um implante de cada superfície foi utilizado para execução da análise de torque de remoção. Enquanto isso, o outro implante foi utilizado para execução de cortes histológicos não-descalcificados e para avaliação do contato direto entre o osso e a superfície do implante (%BIC) e da fração de área de tecido ósseo entre as roscas dos implantes (%BBT). Os implantes com superfície hidrofílica apresentaram maiores valores de torque de remoção no período de 8 semanas (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) e maiores valores de %BIC (42.92 ± 2.85 % vs. 29.49 ± 10.27 %) e de %BBT (34.32 ± 8.52 % vs. 23.20 ± 6.75 %) do que os implantes com superfície hidrofóbica no período experimental de 2 semanas. Implantes com superfície hidrofílica apresentaram aceleração no processo de osseointegração, que culmina em uma maior estab... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
24

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético

Machado, Ana Cristina Posch [UNESP] 13 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-13Bitstream added on 2014-06-13T19:01:08Z : No. of bitstreams: 1 machado_acp_dr_sjc.pdf: 3944406 bytes, checksum: 12231bfae0b05fe47117cdc9fa22d4f3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou–se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... / The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below)
25

Strontium ranelate improves alveolar bone healing in osteopenic rats /

Momesso, Gustavo Antonio Correa. January 2017 (has links)
Orientador: Roberta Okamoto / Coorientador: Leonardo Perez Faverani / Banca: Idelmo Rangel Garcia Junior / Banca: Ronaldo Célio Mariano / Resumo: Este estudo objetivou avaliar o reparo ósseo alveolar em ratas osteopênicas tratadas com ranelato de estrôncio. Trinta e três ratas fêmeas com 3 meses de idade foram selecionadas e divididas em 3 grupos experimentais: OVX (animais submetidos à ovariectomia sem tratamento medicamentoso); SHAM (animais submetidos à cirurgia fictícia sem tratamento medicamentoso) e OVX-RE (animais submetidos à ovariectomia e tratados com ranelato de estrôncio). Inicialmente, os animais foram submetidos à cirurgia de ovariectomia bilateral para indução de condição osteopênica. O tratamento medicamentoso iniciou 30 dias após o procedimento cirúrgico com duração até o momento de eutanásia. Trinta dias após o início do tratamento, foi realizado a extração do incisivo superior direito dos animais para posterior avaliação do reparo alveolar. Os animais do grupo descalcificado foram submetidos à eutanásia aos 14 dias após a extração dentária, sendo as amostradas destinadas às análises histológica e imunoistoquímica. Os animais do grupo calcificado foram submetidos à eutanásia aos 60 dias após a extração dentária, sendo as amostras destinadas às análises por microscopia confocal e microtomográfica. Os resultados histológicos evidenciaram que o grupo OVX-RE demonstrou melhor aspecto de neoformação óssea, com trabéculas mais espessas e baixa presença de tecido conjuntivo, comaprado ao grupo OVX. Os resultados imunoistoquímicos demonstraram intensa marcação de OPG para o grupo OVX-RE e intensa marcação de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed evaluate alveolar bone healing in osteopenic rats treated with strontium ranelate. Thirty-three three months's old female rats were selected and diveded into three groups: OVX (animals underwent to ovariectomy with no drug treatment); SHAM (animals underwent to fake surgery with no drug treatment) and OVXSR (animals underwent to ovariectomy treated with strontium ranelate). Firstly, animals undewent to bilateral ovariectomy to induce osteopenic condition. Drug treatment started at 30 days after, during the all experimental period. Thirty days after, it was performed extraction of the right upper incisor tooth, to further evaluation of alveolar healing. Animals from decalcified group were euthanized at 14 days after tooth extraction, and its samples were destinated to histological and immunohistochemestry analysis. Animals from calcified group were euthanized at 60 days and its samples were destinated to confocal microscopy and micro-tomography analysis. Histological results showed that OVX-SR group had the better aspect of new bone formation, with few number of trabecular bone and poor presence of connective tissue compared to OVX group. Immunohistochemestry results showed an intense labeling of OPG for OVX-SR group and intense labeling of RANKL for OVX group. Regarding confocal microscopy analysis, it was possible observed that OVX-SR group showed a significance greater amount of alizarin precipitation compared to another both groups (Tukey test - P < 0.05).... (Complete abstract click electronic access below) / Mestre
26

Avaliação da influência da quimioterapia com cisplatina ou 5-fluorouracil sobre o processo de reparo ósseo em implantes osseointegrados instalados em tíbias de ratos expostos ou não à nicotina /

Matheus, Henrique Rinaldi. January 2019 (has links)
Orientador: Juliano Milanezi de Almeida / Banca: Edilson Ervolino / Banca: Estevam Augusto Bonfante / Resumo: Objetivo: avaliar a influência da nicotina e dos agentes antineoplásicos Cisplatina (CIS) e 5-fluorouracil (5-FU) sobre os tecidos peri-implantares, bem como os efeitos desses agentes antineoplásicos sobre os tecidos peri-implantares em animais previamente expostos à nicotina. Material e métodos: 180 ratos machos (Wistar) foram randomizados para dois grandes grupos (n=90), NIC e SS, em seguida, para três subgrupos (n=30) de acordo com os agentes antineoplásicos. Receberam 0,5ml de solução de cloreto de sódio 0,9% (SS) ou 3 mg/kg de hemissulfato de nicotina (NIC), de acordo com cada grupo, 30 dias antes e 30 dias após a cirurgia. No dia 0, todos os animais receberam os implantes de titânio (DSP Biomedical®, 4 mm x 2,2 mm) nas tíbias direita e esquerda. Aos 30 dias após a cirurgia, as aplicações de SS e NIC foram interrompidas por 5 dias e, aos 35 e 37 dias, foram administrados os agentes antineoplásicos CIS, 5-FU ou 0,5 ml de SS, via intraperitoneal, respeitando intervalo de 48 h entre as aplicações. Para CIS, 5 mg/kg e 2,5 mg/kg, e para 5-FU, 60 mg/kg e 40 mg/kg, respetivamente. SS-SS: receberam SS via subcutânea e intraperitoneal. SS-CIS: receberam SS via subcutânea e CIS via intraperitoneal. SS-5FU: receberam SS via subcutânea e 5-FU via intraperitoneal. NIC-SS: receberam NIC via subcutânea e SS via intraperitoneal. NIC-CIS: receberam NIC via subcutânea e CIS via intraperitoneal. NIC-5FU: receberam NIC via subcutânea e 5-FU via intraperitoneal. Dez animais por grupo/período... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: to evaluate the influence of nicotine and the antineoplastic agents Cisplatin (CIS) and 5-fluorouracil (5-FU) over the peri-implant tissues, as well as the effects of these agents over peri-implant tissues in animals previously exposed to nicotine. Material and Methods: 180 male rats (Wistar) were initially randomized to two groups (n=90), NIC and SS. Then, to three subgroups (n=30) according to the protocol of antineoplastic agents. Received 0.5 ml of sodium chloride 0.9% (SS) or 3 mg/kg of nicotine hemissulfate (NIC) according to each group, subcutaneously, 30 days before and after surgical procedure for implants placement. At day 0, all animals received the titanium implants (DSP Biomedical®, 4 mm x 2.2 mm) in both right and left tibiae. At 30 days after surgery SS and NIC was interrupted, and at 35 and 37 days were intraperitoneally administered the antineoplastic agents CIS, 5FU or 0.5 ml SS, with 48 h interval between applications. For CIS, 5 mg/kg and 2,5 mg/kg, and 5-FU, 60 mg/kg and 40 mg/kg, respectively. SS-SS: received SS subcutaneously and intraperitoneally. SS-CIS: received SS subcutaneously and CIS intraperitoneally. SS-5FU: received SS subcutaneously and 5-FU intraperitoneally. NIC-SS: received NIC subcutaneously and SS intraperitoneally. NIC-CIS: received NIC subcutaneously and CIS intraperitoneally. NIC-5FU: received NIC subcutaneously and 5-FU intraperitoneally. Ten animals per group and period were euthanized at 50, 65 and 95 days after implants placement. The collected specimens were fixed in buffered formaldehyde solution 4% for 48h and assigned to ground section processing for analysis of bone/implant contact (BIC), or conventional histologic processing with demineralization and paraffin embedding for histometric analysis of percentage of newly-formed bone (PNFB) (Complete abstract electronic access below) / Mestre
27

Utilização sistêmica de estrôncio não radioativo como potencializador da osseointegração de implantes : avaliação biomeânica, microtomográfica e histomorfométrica em ratos /

Scardueli, Cássio Rocha. January 2014 (has links)
Orientador: Elcio Marcantonio Junior / Co-orientador: Rosemary Adriana C. Marcantonio / Banca: Luis Antonio Pugliessi Lima / Banca: Rubens Spin Neto / Resumo: Medicamentos a base de bisfosfonatos têm sido amplamente empregados para tratar enfermidades como osteoporose, mieloma múltiplo, doenças reumáticas e neoplasias com metástases ósseas. No entanto, não podem ser usados rotineiramente na clínica odontológica em favor da maior reparação óssea e osseointegração devido a seus mecanismos específicos e por estarem constantemente relacionados a problemas como alta permanência da droga no organismo e risco de necroses ósseas. Medicamentos a base de estrôncio surgem como novas formas de tratamento para pacientes osteoporóticos bem como uma possível indicação para o uso coadjuvante em procedimentos cirúrgicos, favorecendo a nova formação óssea. Diante das vantagens oferecidas pelos medicamentos a base de estrôncio, como ranelato de estrôncio e cloreto de estrôncio/carbonato de estrôncio, este trabalho teve como objetivo avaliar a osseointegração de implantes em tíbias de ratos. Foram utilizados 70 ratos Rattus Norvegicus, machos, divididos aleatoriamente em 5 grupos: S-Controle (soro); RE 50 (Ranelato de Estrôncio 50 mg); RE 625 (Ranelato de Estrôncio 625 mg); ClECaE 30 (Cloreto Estrôncio e Carbonato Estrôncio 30 mg); ClECaE 365 (Cloreto Estrôncio e Carbonato de Estrôncio 365 mg). Os medicamentos foram administrados diariamente, via gavagem, de acordo com cada grupo, iniciando 15 dias antes do procedimento cirúrgico (1 implante em cada tíbia), persistindo até o final do experimento 15 ou 60 dias. Testes biomecânicos foram realizados com os implantes do lado direito através do contra-troque de remoção, e os implantes no lado esquerdo foram realizadas microtomografias e análises histomorfométricas. Os resultados mostraram uma melhora na osseointegração, principalmente nos grupos ranelato estrôncio 62mg e cloreto estrôncio/carbonato estrôncio 365mg nos testes biomecânicos e microtomográficos. O medicamento a base de estrôncio teve uma influência positiva... / Abstract: Drugs containing bisphosphonates have been widely used to treat diseases such as osteoporosis, multiple myeloma, myeloproliferative disease and cancer with bone metastases. However, can not be used routinely in dental practice in favor of greater bone repair and osseointegration due to its specific mechanisms and are constantly related issues such as high permanence of the drug in the body and risk of bone necrosis. Drugs based on strontium emerge as new forms of treatment for osteoporotic patients as well as a possible indication for adjuvant use in surgical procedures, promoting new bone formation. Given the advantages offered by drugs containing strontium as strontium ranelate and strontium chloride/strontium carbonate , this study aimed to evaluate the osseointegration of implants in rat tibia. Were used 70 rats Rattus Norvegicus, males, randomly divided into 5 groups: S (control-serum physiologic); RE50 (Strontium Ranelate 50 mg); RE 625 (Strontium Ranelate 625 mg); ClE/CaE 30 (Strontium Carbonate and Strontium Chloride 30 mg); ClE/CaE 365 (Strontium Carbonate and Chloride Strontium 365 mg). The drugs were administered daily by gavage according to each group, starting 15 days before surgery (1 implant in each tibia) and persisted until the end of the experiment 15 or 60 days. Biomechanical tests were performed with the right implants through shift against removal, and implants in the left side microtomography and histomorphometric analysis were performed. The results showed an improvement in osseointegration, especially in groups strontium ranelate 625mg and strontium cloride/strontium carbonate 365mg in microtomography and biomechanical testing. The drug strontium base had a positive influence on osseointegration of implants, especially strontium chloride/strontium carbonate, can be incorporated into prevention, treatments of pathologies and surgical procedures as adjunct to implant placement. / Mestre
28

Comportamento de implantes de cimento portland em fase sólida : análise dimensional e histomorfométrica / Fernando Luiz Zanferrari ; orientador, Wilson Denis Martins

Zanferrari, Fernando Luiz January 2011 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 69-73 / Objetivos: O objetivo deste trabalho foram avaliar a estabilidade dimensional do cimento Portland branco quanto ao seu volume e área superficial, mensurar a quantidade de tecido ósseo neoformado por meio de histomorfometria após implantação subperióstea d / Objectives: The aim of this study was to evaluate the dimensional stability of white Portland cement as its volume and surface area, measure the amount of new bone by histomorphometry after subperiosteal implantation of samples of Portland cement in the f
29

Modelagem e análise de tensão em estrutura óssea com implante metálico, através do método dos elementos finitos

Hayasaki, Cláudio Luís [UNESP] 15 June 2007 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-15. Added 1 bitstream(s) on 2016-04-01T18:00:28Z : No. of bitstreams: 1 000545464.pdf: 4772196 bytes, checksum: f68c3fe8004accdb448a75c562dc519b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The goal of this paper was to simulate through the Finite Element Method, the bone structure of rabbits (tibia), when subjected to a determined static transversal loading, and validate the numerical model obtained in the software Ansys. The mechanical behaviour of biomechanical structures, as tibia, femur, bones in general, are too much similar as mechanical structures, for example beams, bars, pipes, bridges, trusses, and so on. There were several difficulties in generating the three-dimensional model; we can numerate them. The first was to build the model exactly with all the irregular surfaces. For solve this problem, we measured along the length of the tibia for each five millimeters, beginning on the position of the implant. The second difficulty was to separate different materials that constitute the body of the bone, for instance, the cortical bone and the medular bone, as well as the region of implant of titanium. We differentiate the regions where each type of bone occurs, including the osseointegrated region. The third difficulty was to represent the load that acted over the bone structure. We adopt the load as a distributed pressure located over the region of the implant. The finite element model was simulated by Ansys software, where was applied tetrahedricals elements. For validating the model, the results were checked with the bibliography revision. We compare the results of intensity of maximal stress generated by the model with the maximal stress obtained experimentally. We conclude that was a reasonable approach, considering the accuracy of the constructed model.
30

Efeito in vivo da deposição de filmes de DLC com e sem nanopartículas de prata sobre liga de titânio para utilização em próteses articulares

Ankha, Milagros del Valle El Abras [UNESP] 14 January 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-14. Added 1 bitstream(s) on 2016-04-01T18:01:07Z : No. of bitstreams: 1 000860852.pdf: 2757457 bytes, checksum: 0890782e9186eca88c763633aa7bfdd1 (MD5) / Materiais de revestimento duros para melhorar as propriedades biotribológicas das próteses articulares, estão sendo foco de pesquisa há algum tempo. Vários tipos de filmes de carbono têm sido descritos relatando falhas e sucessos e também sugerindo a necessidade de mais pesquisas. Frente a isso, este trabalho teve o objetivo de avaliar as características estruturais e de neoformação óssea de filmes de carbono tipo diamante com e sem nano-partículas de prata (DLC e DLC-Ag, respectivamente), aplicados por plasma (PECVD) em liga de titânio (Ti-6Al-4V). Sessenta amostras de Ti-6Al-4V, foram dividas em três grupos nos quais: 20 eram recobertas com filme de DLC, 20 com DLC-Ag e 20 sem recobrimento. Após a caracterização estrutural, as amostras foram fixadas bilateralmente no ângulo da mandíbula de 30 coelhos da raça Nova Zelândia. Após os períodos de 15 e 90 dias os animais foram eutanasiados e cinco amostras por grupo foram escolhidas aleatoriamente para a caracterização pósoperatória e cinco para análise qualitativa e quantitativa da neoformação óssea. Os dados foram tratados estatisticamente, por análise descritiva e inferencial, mediante o teste paramétrico ANOVA dois fatores de medidas repetidas e quando foi necessário o teste de comparação múltipla de Tukey (p<0,05%). Verificou-se que os filmes de DLC e DLC-Ag apresentaram alta resistência elétrica e não sofreram grandes modificações em seu espectro Raman, após os períodos de 15 e 90 dias. Na análise histológica após o período de 15 dias, observou-se trabéculas ósseas imaturas proliferando do osso preexistente em direção à amostra e, por vezes, recobrindo parcialmente a superfície da mesma. No período de 90 dias foi difícil delimitar a área de osso neoformado do preexistente, apresentando-se com as características de osso maduro e organizado, abrangendo a interface quase na sua totalidade, na maioria doos casos. Isto foi observado nos três.. / Hard coating materials to improve the biotribologic properties of joint prostheses have been the focus of research for some time. Various types of carbon films have been described, reporting failures and successes and also suggesting the need for more research. Because of that, the aim of this work was to evaluate the structural characteristics and biocompatibility of diamond-like carbon films with and without nano-particles of silver (DLC and DLC-Ag, respectively), applied by plasma (PECVD) on a titanium alloy (Ti-6Al-4V). Sixty samples of Ti-6Al-4V, were divided into three groups in which 20 were coated with DLC film, 20 with DLC-Ag and 20 without coating. After the structural characterization, samples were fixed bilaterally in the mandible angle of 20 rabbits of New Zealand race. After periods of 15 and 90 days the animals were euthanized and five samples per group were randomly assigned to postoperative characterization and five for qualitative and quantitative analysis of new bone formation. The data were treated statistically, using descriptive and inferential analysis, by ANOVA parametric test two factors for repeated measures and when necessary, the multiple comparison test of Tukey (p<0.05%). It has been found that the DLC and DLC-Ag films showed high electrical resistance and did not suffer significant changes in its Raman spectrum after periods of 15 and 90 days. Histological examination after 15 days showed proliferating immature bone trabeculae, from the preexisting bone in the direction of the sample and .and sometimes partially covering its surface. At 90 days it was difficult delineate the newly formed bone area of the preexisting. Mature and organized bone was seen within the interface, comprising almost its entirety, in most cases. This was observed in all groups, confirming the results obtained in the histomorphometric analysis, there was no statistically significant ...

Page generated in 0.0634 seconds