• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • Tagged with
  • 19
  • 19
  • 13
  • 11
  • 10
  • 10
  • 10
  • 8
  • 7
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães /

Lenharo, Ariel. January 2003 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Marco Antonio Bottino / Banca: Luiz Fernando Pegoraro / Banca: Mauro Antônio Arruda Nóbilo / Banca: Tetuo Okamoto / Resumo: O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / Abstract: The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation. / Doutor
12

Índice de sucessos de implantes osseointegráveis que receberam carga imediata unitária : avaliação clínica de curto período em humanos /

Ribeiro, Fernando Salimon. January 2004 (has links)
Resumo: O objetivo deste estudo foi comparar, em curto período de tempo, o índice de sucesso de implantes osseointegráveis unitários submetidos à carga imediata, colocados imediatamente após a exodontia, com implantes colocados em rebordos cicatrizados. Foram examinados 71 pacientes consecutivos totalizando 91 implantes, sendo 48 realizados em clínica privada e 43 em cursos de especialização em implantodontia, entre dezembro de 2001 a dezembro de 2003. Sessenta e três implantes foram instalados em alvéolos e 28 em rebordos. Os critérios utilizados para avaliar o índice de sucesso foram os descritos por Albrektsson e Zarb (1993). Após o período de avaliação, 87 implantes examinados enquadravam-se dentro dos critérios de sucesso (95,6%). Dos quatro implantes perdidos, três haviam sido colocados em alvéolos (índice de sucesso de 95,2%) e um, em rebordo (96,4%). A diferença entre os índices de sucesso dos dois grupos não foi estatisticamente significante (p=0,76, teste Qui-quadrado). Podemos concluir, dentro das limitações deste estudo, que o carregamento imediato de implantes unitários, seja colocado em alvéolo ou rebordo, representa uma alternativa terapêutica com alta previsibilidade, comparado aos resultados encontrados na literatura para implantes seguindo o protocolo convencional de dois estágios cirúrgicos. / Abstract: The aim of this study was to evaluate, in a short period of time, the success rate of immediate loading of single-tooth implants: immediate versus non-immediate implantation. Seventy-one patients were examined, totalizing 91 implants, which 48 implants were placed in private practice office and 43 were placed in dental school, between December 2001 and December 2003. Sixty-one implants were placed in fresh extraction sites, and 28 were placed in healed sites. Criteria to evaluate success rate were previously described by Albrektsson and Zarb (1993). After follow-up evaluation, 87 implants fulfilled the success rate criteria (95,6%). Four implants were lost, and among these, three were placed in fresh extraction sites (success rate 95,2%), and one placed in healed sites (success rate 96,4%). Rates of success between both groups was not statistically significant (p=0,76, Qui-square test). Within the limitation of the present study, it could be concluded that single-tooth osteointegrated implants submitted to immediate loading, in immediate and non-immediate implantation, represent a therapeutic alternative with high predictability, compared to the conventional protocol. / Orientador: Elcio Marcantonio Junior / Coorientador: Elcio Marcantonio / Banca: Luis Antônio Borelli Barros / Banca: Wilson Trevisan Junior / Mestre
13

O efeito da ciclosporina-A na osseointegração /

Sakakura, Celso Eduardo. January 2005 (has links)
Resumo: Agentes imunossupressores provocam alterações severas no metabolismo ósseo mineral podendo resultar em osteopenia. Tais alterações podem ser prejudiciais no processo e manutenção da osseointegração. Este estudo teve o objetivo de avaliar a influência da administração de ciclosporina-A (CSA) na osseointegração de implantes de titânio, através da avaliação: durante a cicatrização óssea ao redor de implantes dentais (Estudo I); da densidade óssea ao redor implantes dentais (Estudo II); da retenção do implante após a cicatrização óssea de implantes dentais (Estudo III) e radiográfica da qualidade óssea ao redor de implantes dentais já osseointegrados (Estudo IV). Os resultados permitiram concluir que a administração de CSA durante a cicatrização óssea resulta em diminuição da osseointegração e da densidade óssea ao redor do implante dental. Ainda, a administração de CSA após o período de cicatrização óssea ao redor do implante reduz a sua retenção mecânica ao tecido ósseo e promove a diminuição da qualidade e da densidade óssea radiográfica ao redor do implante dental. / Abstract: Immunosupressive agents may induce severe changes on bone mineral metabolism resulting in osteopenia. These alterations may impair the osseointegration processes. The purposes of this study were evaluate the cyclosporin-A (CSA) influence: on bone healing around dental implants (Study I); on bone density around dental implants (Study II); on mechanical retention of dental implants integrated to the bone (Study III) and on radiographic bone density and quality around dental implants integrated to the bone (Study IV). The CSA administration may impair the osseointegration and bone density during the bone healing. Besides, the administration of CSA after bone healing may impair the dental implant mechanical retention and decrease the radiographic bone density and bone quality around dental implants integrated to the bone. / Orientador: Gulnara Scaf / Coorientador: Elcio Marcantonio Junior / Banca: Guilherme Monteiro Tosoni / Banca: Maria Lúcia Rubo de Rezende / Banca: Jamil Awad Shibli / Banca: Francisco Haiter Neto / Doutor
14

Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato /

Lemo, Vagner Samy. January 2004 (has links)
Resumo: Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / Abstract: The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Trevisan Junior / Mestre
15

Osseointegração de implantes de titânio com modificação da superfície por ablação a laser e recobrimento por hidroxiapatita biomimética : estudo biomecânico e histomorfométrico em tíbia de coelhos /

Faeda, Rafael Silveira. January 2010 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Celso Eduardo Sakakura / Banca: Ana Emília Farias Pontes / Banca: Andréa Cândido dos Reis / Banca: Maria Lúcia Rubo de Rezende / Resumo: O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - LMS e recoberta por hidroxiapatita biomimética - HA), comparando-as a outro implante comercial, (superfície usinada - MS). Um total de 144 implantes (3,75 x 10mm), 48 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, um dos implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. O outro implante foi removido com o tecido ósseo peri-implantar e processado por corte histológico calcificado para análise histomorfométrica do contato osso-implante (BIC%) e da área óssea entre espiras (BBT%). Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes LMS quando comparados aos MS. Após 12 semanas, os implantes HA e LMS foram estatisticamente superiores aos implantes MS. Por outro lado, a análise do contato osso-implante mostrou que na região cortical, os implantes LMS e HA foram estatisticamente superiores ao MS para todos os períodos de cicatrização, sem diferença estatística entre LMS e HA. A análise histomorfométrica mostrou que, quando comparados na região endosteal, os implantes LMS e HA foram estatisticamente superiores ao MS no período inicial de cicatrização. Embora os implantes LMS e HA não apresentassem diferenças estatísticas entre eles, uma tendência de maiores valores de BIC% para HA na região endosteal foi observada em todos os períodos do estudo.Os resultados deste estudo mostram que apesar de não haver diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: Considering the great biological potential of the association between laser ablation and hydroxyapatite thin layer coatings to create an interesting bioactive environment on titanium dental implants, the aim of the present study was to investigate, by histomorphometrical and removal torque analysis, the histological effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process compared to implants with only laser-ablation and implants with machined surfaces. Materials and Methods: Forty-eight rabbits received two implant by tibiae of the following surfaces: Machined surface (MS), laser-modified surface (LMS) and biomimetic hydroxiapatite coated surface (HA). After 4, 8 and 12 weeks of healing, one implant was exposed, and the needed force to unscrew measured using an analogical torque gauge. The other implant and surrounding bone was removed and prepared by a calcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area formed between the threads (BBT) were evaluated separately to the cortical and endosteal region. Results: The difference was statistically significant (P < .05) between the LMSMS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating. Average BIC percentage in the cortical region was significantly higher (P<0.001) on the LMS and HA implants, compared with MS ones for all periods of healing, having no statistical differences between LMS and HA. When compared in the endosteal area, the LMS and HA implants showed statistically higher (P<0.01) BIC percentage values than MS at the initial periods of healing (LMS after 4 weeks and HA after 4 and 8 weeks, respectively)... (Complete abstract click electronic access below) / Doutor
16

Influência do Diabetes mellitus e da insulinoterapia na osseointegração. Análise por torque reverso em tíbia de coelhos. /

Margonar, Rogério. January 2002 (has links)
Resumo: A indicação da colocação de implantes dentais osseointegrados (IDO) para pacientes com comprometimento sistêmico, como o Diabetes, permanece controversa. O objetivo deste estudo foi avaliar, por meio do torque reverso, a influência do Diabetes Mellitus e, de seu controle com insulina, sobre a osseointegração ao redor de implantes. Foram utilizados 34 coelhos adultos da raça Nova Zelândia, os quais foram divididos nos seguintes grupos: grupo controle (C), grupo Diabetes (D) e grupo Diabetes controlado (DC). A indução do Diabetes foi realizada por administração endovenosa de Aloxana (115 mg/kg). Os coelhos do grupo DC receberam tratamento com injeção subcutânea de insulina (10 U/ dia) e os demais receberam solução salina (0,9%) pela mesma via. Após 1 semana, realizou-se cirurgia de instalação bilateral de implantes nas tíbias de cada animal. Os níveis glicêmicos foram avaliados periodicamente pelo método enzimático da glicose -oxidase. Após 4, 8 e 12 semanas, os animais foram sacrificados e os implantes removidos, sendo o teste do torque de remoção dos mesmos executado com torquímetro manual. No período de 4 semanas, não houve diferenças estatisticamente significativas (p=0.2) entre os grupos quanto ao valor do torque de remoção dos implantes. Porém, o grupo C apresentou valores estatisticamente superiores em relação aos grupos D e DC nos períodos de 8 (p=0.0001 e p=0.0053, respectivamente) e 12 semanas (p=0.0002 e p=0.001, respectivamente). Os grupos D e DC não apresentaram diferenças entre si em nenhum dos períodos avaliados. Assim, pode-se concluir que o Diabettes Mellitus influenciou negativamente a osseointegração de implantes colocados em tíbias de coelhos e a insulinoterapia não alterou este efeito. / Abstract: The indication for the placement of osseointegrated dental implants in patients with systemic illness, like diabetes, remains controversial. The purpose of this study was to evaluate, through the removal torque test, the influence of Diabetes Mellitus and its control with insulin, on osseointegration around implants. Thirty four New Zealand adult rabbits were separated in 3 groups: control group (C), diabetes group (D) and controlled diabetes group (CD). Aloxana (115mg/kg) was used in diabetes induction. The CD group received treatment with insulin (10 U/ day) and the others received saline solution (0,9%). After 1 week, implants were placed bilaterally in the tibiae of rabbits. After 4, 8 and 12 weeks, the animals were sacrificed and the implants were removed been the removal torque test performed with the aid of a manual torquimeter. At 4 weeks, there were no significant differences (p=0.2) among groups regarding the value for implants removal torque. However, C group showed statistically greater values than D and CD groups at 8 (p=0,0001 and p=0.0053, respectively) and 12 weeks (p=0.0002 and p=0.001, respectively). The groups D and CD didn't showed any significant differences between each other in any period evaluated. Thus, it may be concluded that Diabettes Mellitus can negatively influence the osseointegration around implants in tibiae of rabbits and insulin therapy did not altered this effect. / Orientador: Elcio Marcantonio Junior / Coorientador: Maria Teresa Pepato / Banca: Luis Carlos Spolidorio / Banca: Elton Gonçalves Zenóbio / Mestre
17

Osseointegração de implantes usinados e oxidados em seio maxilar preenchido por coágulo com ou sem osso autógeno : estudo histológico, histométrico e de RFA em macacos /

Palma, Vinícius Canavarros. January 2006 (has links)
Resumo: O objetivo deste estudo experimental foi comparar histologicamente o preenchimento do assoalho do seio maxilar por coágulo local com ou sem a associação de osso autógeno (controle), bem como investigar a osseointegração em duas diferentes superfícies de implante sob essas condições, através de medidas histométricas, análises histológicas e em freqüência de ressonância (RFA). Quatro macacos prego (tufted capuchin) tiveram todos os pré-molares e os primeiros molares superiores extraídos. Após quatro meses de reparo, os animais foram submetidos a cirurgia para acessar o assoalho do seio maxilar, através de uma janela óssea, para elevação da membrana do seio. O seio direito foi deixado para que se reparasse espontaneamente (somente coágulo), enquanto o esquerdo foi preenchido com enxerto ósseo autógeno. A membrana dos seios foram mantidas elevadas pela inserção simultânea de dois implantes (um usinado e outro oxidado eletroliticamente, Sistema Branemark®, Nobel Biocare) em cada lado da maxila. A estabilidade dos implantes foi acessada através da freqüência de ressonância (RFA, Ostell®) no momento da fixação dos implantes e no dia do sacrifício. Com a injeção de fluorocromos foi possível investigar o processo de neoformação óssea nos animais bem como relacioná-lo às diferentes superfícies dos implantes. Os animais foram sacrificados 6 meses após a cirurgia para análise histológica e de histomorfometria (contato-osso-implante - BIC, área de osso nas roscas - BA, e área de osso em um retângulo desenhado - BAR). Concluímos que não houve diferença entre o seio preenchido somente com coágulo local e o seio preenchido com osso autógeno, em relação à RFA, BIC, BA e BAR...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This experimental study aimed at comparing histologically the use of coagulum alone or autogenous bone graft (control) for sinus floor augmentation procedures as well as investigating the role played by implants surface on osseointegration under such circumstances, as measured by histological, histometric and resonance frequency analysis (RFA). Four tufted capuchin monkeys had all upper premolars and 1st molar extracted bilaterally. Four months later the animals underwent maxillary sinus floor augmentation surgery using the window technique. The right sinus was left to heal spontaneously (coagulum alone), whilst the left sinus was filled with autogenous bone graft. The Schneider's membrane was kept elevated by insertion of two implants (machined and oxidized, Bränemark System) in both sinuses. Implant stability was assessed through resonance frequency analysis (RFA, Osstell) at installation and at sacrifice. The pattern of bone formation in all experimental sites as well as related to the different implants surface was investigated using fluorochromes. The animals were sacrificed 6 months after MSFA for histology and histomorphometry (bone-to-implant contact - BIC, bone area in threads - BA, and bone area in rectangle - BAR). The results showed no difference between coagulum and bone graft sites regarding RFA, BIC, BA and BAR. As to BIC, the oxidized implants exhibited improved integration compared with machined ones. Oxidized implants showed higher BA compared to machined implants in bone grafts. The amount of bone tissue do not differ in coagulum alone and autogenous bone sites. Histologically, new bone is frequently deposited in contact with Schneider's membrane in coagulum alone sites, confirming the osseoinductive potential of the membrane. The oxidized implants should be preferred to machined implants in sinus floor augmentation procedures. / Orientador: Osvaldo Magro Filho / Coorientador: Luiz Antônio Salata / Banca: Luis Eduardo Marques Padovan / Banca: Renato Mazzonetto / Banca: João Gualberto Cerqueira Luz / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Sérgio Perri de Carvalho / Doutor
18

Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhos /

Faeda, Rafael Silveira. January 2006 (has links)
Resumo: O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - SML e recoberta por hidroxiapatita biomimética - HA), comparando-as a outros dois implantes comerciais, (superfície usinada - SU e modificada por jateamento e ataque ácido - SMC). Um total de 96 implantes (3,75 x 10mm), 24 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, os implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes SML quando comparados aos SU. Após 12 semanas, os implantes HA e SML foram estatisticamente superiores aos implantes SU. Os resultados deste estudo sugerem que os implantes HA foram superiores aos demais nos períodos iniciais, obtendo uma estabilidade satisfatória com 4 semanas de implantação. Os implantes SML foram superiores aos SU em todos os períodos avaliados, porém não apresentando diferenças quando com parados aos SMC. / Abstract: The success of modern dental implant systems has been associated with the development of implant designs and surface characteristic. The purpose of this study was to evaluate two new implant surfaces (laser-modified - LSM and biomimetic-hydroxyapatite coating - HA) comparing them with two other commercial implants (machined surface -MS and modified by sandblasted and acid etched - MCS). A total of 96 implants (3,75 x 10mm), 24 of each surface, were placed in rabbit tibia being evaluated after 4, 8 and 12 weeks. After the healing periods, the animals were sacrificed, the implants sites were exposed, and the needed force to unscrew the implants was measured using an analogical torque gauge. At 4 and 8 weeks, the HA implants removal torque was statistically greater (p<0,05) in comparison with the others, being the same observed to LSM when compared with MS. After 12 weeks, the HA and LSM implants were statistically greater just when compared with MS. The results of this study suggest that the HA implants were superior to the other at the initial periods, having a satisfactory stability with 4 weeks post-implantation. The LSM implants were superior to MS at all periods evaluated, but having no difference when compared with MCS. / Orientador: Elcio Marcantonio Junior / Coorientador: Antonio Carlos Guastaldi / Banca: Idelmo Rangel Garcia Junior / Banca: Maria Lucia Rubo de Rezende / Mestre
19

Implantes porosos de titânio puro grau 2 : osseointegração em tíbias de coelho /

Vasconcellos, Luana Marotta Reis de. January 2005 (has links)
Resumo: O objetivo neste estudo foi avaliar e comparar a reparação óssea ao redor de implantes cilíndricos densos e porosos, ambos de titânio puro grau 2, confeccionados via metalurgia do pó, por meio de análise histológica, histomorfométrica e teste mecânico de cisalhamento. Previamente à cirurgia, todos os implantes foram caracterizados por meio de análise metalográfica e os implantes densos foram submetidos também a um rugosímetro. Em seguida, os implantes foram inseridos em tíbias de coelhos. Concluiu-se, portanto, que a técnica de metalurgia do pó é eficiente para produzir implantes densos e porosos, e que os porosos apresentam maior contato na área de interface osso-implante e maior adesão ao osso, melhorando a osseointegração deste implante ao tecido ósseo. / Abstract: The aim of this study was to assess and compare the bone repair around dense and porous cylindrical implants, both made of commercially pure titanium by means of powder metallurgy. Histological analysis, histomorphometric analysis, and mechanical test were carried. Prior to the surgery, all implants were characterized by means of metallographic analysis. The dense implants were also submitted to perfilometer equipment. Following the implants were placed in the rabbit tibiae. Thus, these findings suggest that the powder metallurgy technique is efficient to produce dense and porous implants, and that the porous implants exhibit greater contact in the implant-bone interface and greater adhesion to the bone, therefore improving the osseointegration of this implant to the bone. / Orientador: Yasmin Rodarte Carvalho / Coorientador: Carlos Alberto Alves Cairo / Banca: Yasmin Rodarte Carvalho / Banca: Marize Varella de Oliveira / Banca: Mario Lima de Alencastro Graça / Banca: Paulo Villela Santos Júnior / Banca: Rosilene Fernandes da Rocha / Doutor

Page generated in 0.1388 seconds