Spelling suggestions: "subject:"tut"" "subject:"uut""
331 |
Pregnancy related telephone consultations to an out-of-hours provider: a retrospective database studyHaith-Cooper, Melanie, Stacey, T., Clements, E., Mohammed, Mohammed A., Edwards, E. January 2015 (has links)
Yes / There is a marked increase in the number of General Practitioner (GP) organisations
across Europe providing out of hours (OOH) emergency primary care services
whereby GPs and/or Nurse Practitioners (NPs), provide telephone consultations to
patients (Giesen et al., 2007a, McKinstry et al., 2009, Derkx et al., 2009). This has
been an important development to manage the rising demand for health care with
increasingly scarce resources (Blank et al., 2012, Purc-Stephenson and Thrasher,
2010) and also reduces unnecessary attendance at accident and emergency
departments or home visits by GPs (Bunn et al., 2005, Roberts et al., 2008)...
In this study we describe the characteristics of telephone consultation calls made by
pregnant women to an OOH service run by a GP co-operative and also to compare
and contrast the differences between the way the calls were handled by GPs and
Nurse Practitioners (NPs). The NPs were qualified and registered nurses
experienced in primary care or emergency care settings and none were practicing.
|
332 |
Dynamics of Lean Direct Injection CombustorsAradhey, Yogesh Sachin 10 November 2023 (has links)
Improvements to heritage gas turbine engines will be needed in the coming years as the demand made on these systems increase. While industry continually presses for higher performance of both military and civilian aero engines, the government simultaneously raises the bar for emissions standards in the commercial sector to support public health. The next generation of aerospace gas turbine engines will be defined by their ability to operate at high power conditions while maintaining efficiency. This challenge is compounded by airlines' proposition of a return to supersonic flight- an operating regime characterized by higher total temperatures, and thus more NOx production.
Lean Direct Injection (LDI) is a combustion scheme that was proposed by NASA, and inherently addresses the needs of both the private sector and the military. LDI is a liquid fueled combustor that promotes rapid mixing of fuel and air at the entrance of the combustor. Despite the benefits of LDI, it has never been implemented, nor has any other lean burning scheme been implemented in an aircraft due to the system level complications of such technology. This dissertation focuses on the dynamics of thermoacoustic instability and lean blowout (LBO), two of the major complications that industry will face when they attempt to incorporate LDI in a production engine.
The present dissertation investigates these dynamics from a fundamental and applications standpoint. Fundamental insights on thermoacoustic instabilities are developed by investigating droplet dynamics in a self-excited flow field, and significant oscillations in droplet diameters are discerned. PDPA measurement will be taken to identify coupling of the fuel spray with the instability, and a phase locking algorithm will be used to develop a new spray parameter than is more indicative of combustion heat release that the standard Sauter mean diameter.
Next, while varying the swirl number and the venturi geometry of the combustor, the evolution of the flow field will be characterized. An in-house innovation called the Direct Rotation Swirler (DRS) is built for this purpose. The DRS uses an active geometry to provide continuously variable swirl number modulation. The effects of these changes on lean blow out, pressure drop and NOx emissions will then be experimentally determined. Venturis were rapidly manufactured using a ii casting procedure that was developed to make venturi geometries from a commercially available ceramic at very low cost. / Doctor of Philosophy / Improvements to heritage gas turbine engines will be needed in the coming years as the demand made on these systems increase. While industry continually presses for higher performance of both military and civilian aero engines, the government simultaneously raises the bar for emissions standards in the commercial sector to support public health. The next generation of aerospace gas turbine engines will be defined by their ability to operate at high power conditions while maintaining efficiency. This challenge in compounded by airlines' proposition of a return to supersonic flight- an operating regime characterized by higher total temperatures, and thus more NOx production.
Lean Direct Injection (LDI) is a combustion scheme that was proposed by NASA, and inherently addresses the needs of both the private sector and the military. LDI is a liquid fueled combustor that promotes rapid mixing of fuel and air at the entrance of the combustor. Rapid mixing yields a clean, even flame and eliminates the fuel-rich primary zone which is the heart of NOx production.
Despite the benefits of LDI, it has never been implemented, nor has any other lean burning scheme been implemented in an aircraft due to the system level complications of such technology. This dissertation focuses on two of the major complications that industry will face when they attempt to incorporate LDI in a production engine. Drastically reducing the local hot spots in the primary zone is fundamentally necessary to improve pattern factor and emissions, but this change is directly at odds with two dynamic phenomenon that plague combustors. These effects are thermoacoustic instabilities, and lean blow out.
Thermoacoustic instabilities are a major concern in any type of combustor and instabilities are more common and more intense in lean engines which is a significant safety risk to aircraft. A thermoacoustic instability occurs when pressure waves in an engine grow to high amplitudes.
Small pressure waves are normal in any combustion process, but when the acoustic waves couple with the heat release, the waves can grow uncontrollably. The amplitudes can reach magnitudes capable of damaging the combustor or significantly reducing its cyclic life. Due to the high iv standard of safety in the aerospace industry, lean combustion will not be implemented until engines can be designed to avoid instabilities throughout the entire flight envelope.
Lean blow out occurs when the fuel to air ratio of the engine becomes too low to sustain a flame.
Lean blow out is a transient phenomenon that is dependent on local flame speeds, local chemical time scales and turbulence parameters. Typically, lean blow out is combated by designing a rich flame anchoring region that burns with plenty of excess fuel so that even if the fuel flow rate is reduced, a core region is still within its flammability regions.
The present dissertation investigates these dynamics from a fundamental and applications standpoint. Fundamental insights on thermoacoustic instabilities are developed by investigating droplet dynamics in a self-excited flow field, and significant oscillations in droplet diameters are discerned. PDPA measurement will be taken to identify coupling of the fuel spray with the instability, and a phase locking algorithm will be used to develop a new spray parameter than is more indicative of combustion heat release that the standard Sauter mean diameter.
Next, while varying the swirl number and the venturi geometry of the combustor, the evolution of the flow field will be characterized. An in-house innovation called the Direct Rotation Swirler (DRS) is built for this purpose. The DRS uses an active geometry to provide continuously variable swirl number modulation. The effects of these changes on lean blow out, pressure drop and NOx emissions will then be experimentally determined. Venturis were rapidly manufactured using a casting procedure that was developed to make venturi geometries from a commercially available ceramic at very low cost.
|
333 |
Influência da geometria da ponta ativa de carga na resistência de união de contenção intrarradicular à parede dentinária em canais radiculares achatados de raízes distais de molares inferiores / Influence of the load tip geometry on the bond strength of the intraradicular core to dentin walls in distal flattened root canals of mandibular molarsPlotegher, Fernanda 04 July 2018 (has links)
O objetivo deste estudo foi avaliar a influência da ponta ativa de carga circular e achatada na resistência de união (RU) da contenção intrarradicular à parede dentinária de canais radiculares achatados, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (CT), bem como avaliar os padrões de falhas em estereomicroscópio (EM) e microscopia confocal a laser (MCL) e a distribuição de tensão pelo método de elementos finitos. Raízes distais de molares inferiores com secção transversal achatada foram preparadas endodonticamente e armazenadas em 100% de umidade à 37°C por 7 dias. Após este período, as raízes foram submetidas ao preparo do espaço para o PFV Exacto #1 no comprimento de 8,0 mm, correspondente à dois terços do comprimento total da raiz, com brocas Largo #1,0, e complementadas com Brocas Exacto #1. O tratamento da superfície do PFV foi realizada de acordo com a recomendação do fabricante. O PFV foi cimentado com RelyX U200, por meio da seringa Centrix®. As raízes foram armazenadas em 100% de umidade à 37° C durante 7 dias. Para a execução do teste push-out foram confeccionadas pontas ativa de carga com secções transversais achatada e circular. A determinação da secção das pontas foi realizada a partir da proporção de 85% das médias do diâmetro maior e menor de raízes preparadas e restauradas com PFV, obtidos por meio de imagens em CT . Foram fabricadas pontas achatadas de aço inoxidável por meio de micro usinagem e eletroerosão a fio, com 4 secções diferentes, sendo: A-2,89 mm x 1,96 mm; B-2,05 mm x 1,50 mm; C-1,50 mm x 0,84 mm e D-1,20 mm x 0,64 mm. Para a confecção das pontas circulares, a mesma proporção foi calculada, e foram fabricadas de aço inoxidável por meio de usinagem, com 4 diâmetros diferentes, sendo: a-1,2 mm; b-0,90 mm; c-0,70 mm e d-0,50 mm. Para o correto alinhamento das amostras, foram fabricadas dispositivos de poliuretano com orifício central de 2,5 mm; 1,5 mm e 1,0 mm de diâmetro. As raízes foram seccionadas para obtenção de dois slices (1 mm ± 0,2) dos terços cervical e médio (n=64). Um slice de cada terço de um mesmo espécime foi submetido ao teste de push-out com pontas ativas de carga circular (n=32) e achatada (n=32), por meio de dispositivo mecânico MTS acoplado ao CT SkyScan 1174 (50kV, 80mA). Os tipos de falhas foram avaliados por EM e MCL. Para gerar modelo 3D de elementos finitos 2 elementos aleatórios foram escaneados em CT 1146 com 90 kv e 237 mA (filtro de Cu de 0.1 mm) com resolução isotrópica de 9 m e rotação de 360°, para obter imagens do terço cervical e médio, do mesmo elemento. Os dados foram analisados por testes estatísticos paramétricos (p>0,05). Para avaliar a influência do fator tipo de ponta ativa de carga e terço radicular foi utilizado o teste ANOVA. O teste qui-quadrado foi utilizado para avaliar o tipo de falha ocorrida após o teste de RU. As pontas ativas de carga circular (4,39 ± 1,52 Mpa) apresentaram maiores valores de RU (p=0,015) em relação as pontas achatadas (3,60 ± 1,10 Mpa). A análise dos terços radiculares (p=0,032) apresentou maior RU no terço médio (4,34 ± 1,62 Mpa) comparado ao terço cervical (3,65 ± 0,99 Mpa). A interação tipo de ponta de carga ativa x terço não houve diferença estatística (p=0,058). Na análise do padrão de falha em relação ao tipo de ponta (p=0,005), o teste qui-quadrado apresentou maior percentual de falha adesiva à dentina nas pontas achatadas, e nas pontas circulares maior ocorrência de falhas mistas (p=0,005). Na interação terços x padrão de falha, o terço cervical apresentou maior percentual de falhas mistas em relação ao terço médio (p=0,003). E o terço médio apresentou maior percentual de falhas mistas adesivas (p=0,003). No modelo 3D dos slices testados com as pontas achatadas, a interface de união mostrou maior concentração de tensões von misses. Enquanto que as pontas circulares apresentaram concentração de tensão na interface da ponta ativa e o cimento resinoso. Análise de Tensão Máxima confirmou maior quantidade de tensões na interface adesiva dos slices testados com a ponta achatada. Conclui-se que a ponta achatada apresentou melhor comportamento ao apresentarem menores valores de resistência de união da interface adesiva do pino de fibra de vidro e cimento resinoso à parede dentinária de canais distais achatados em molares inferiores / The objective of this study was to evaluate the influence of circular and flattened load active tips on the bond strength (BS) of intraradicular core to dentin walls of flattened root canals of mandibular molars, using the material testing stage (MTS) coupled to a micro-computed tomography (CT) scanner, as well as to analyze the failure patterns using stereomicroscopy (SM) and confocal laser microscopy (CLM) and the stress distribution by the finite element method. Distal flattened root canals of mandibular molars were prepared endodontically and stored in 100% humidity at 37 °C for 7 days. After this period, the post space was prepared with a #1.0 Largo bur and complemented with #1 Exact drills to receive a #1 Exact glass fiber post (GFP) at 8.0 mm length, corresponding to two thirds of the total root length. The GFP surface was treated according to the manufacturer\'s recommendation and the GFP was cemented with RelyX U200, applied with the syringe Centrix®. The roots were stored in 100% humidity at 37 ºC for 7 days. For the push out test, load active tips with flat and circular cross section were provided at 85% ratio of the largest and smallest diameter of the roots prepared and restored with GFP, using CT images. The flattened load tips were fabricated by micromachining and electrical discharging machine, with 4 different cross sections: A-2.89 mm x 1.96 mm; B-2.05 mm x 1.50 mm; C-1.50 mm x 0.84 mm and D-1.20 mm x 0.64 mm. To fabricate the circular load tips, the same proportion was calculated, and were made by machining, with 4 different diameters, being: a-1.2 mm; b-0.90 mm; c-0.70 mm and d-0.50 mm. For the correct alignment of the samples, were manufactured polyurethane devices with central orifice of 2.5 mm; 1.5 mm and 1.0 mm diameter. The roots were sectioned to obtain two slices (1 mm ± 0,2) of cervical and middle thirds (n = 64). One slice of each third of the same specimen was submitted to a push-out test with active circular (32) and flattened (32) load tips, by MTS mechanical device coupled to CT SkyScan 1174 (50kV, 80mA). The failures modes were analyzed by SM and CLM. To create 3D finite element model, 2 random elements were scanned with 1146 CT scan with 90 kV and 237 mA (0.1 mm Cu filter) with 9 m isotropic resolution and 360° rotation to obtain images of cervical and middle root canal thirds of the same tooth. Data were analyzed by parametric statistical tests (p>0.05). The ANOVA test was used to evaluate the influence of the load active tip and root third. The chisquare test was used to evaluate the failure modes occurred after the BS test. The circular load active tips (4.39 ± 1.52 MPa) showed higher BS values (p = 0.015) than the flattened tips (3.60 ± 1.10 MPa). Analysis of the root thirds (p = 0.032) presented higher BS of middle third (4.34 ± 1.62 Mpa) than the cervical third (3.65 ± 0.99 Mpa). The load active tip and root canal third interaction was not statistically significant (p = 0.058). The chi-square test showed (p = 0.005) higher percentage of adhesive failure in the flattened load tip, while the circular load tip showed a higher percentage of mixed failures (p = 0.005). In the root canal third x failure interaction, the cervical third presented higher percentage of mixed failures than middle third (p = 0.003) and the middle third showed higher percentage of adhesive failures (p = 0.003). The 3D model showed higher concentration of von misses stress at the adhesive interface of slices tested with flattened tips, while the circular tips showed stress concentration at interface between active load tip and resin cement. Maximum Voltage analysis confirmed the occurrence of more stresses at the adhesive interface of the slices tested with the flattened load tip. It may be concluded that the flattened load active tip had a better performance with lower bond strength at the adhesive interface between the GFP and resin cement to dentin wall distal flat oval root canals of mandibular molars
|
334 |
Burn out e estilos de coping em enfermeiros que assistem pacientes oncológicos / Burn out and the coping styles used by oncology nurses that assist oncology patientsRodrigues, Andrea Bezerra 18 January 2007 (has links)
Esse estudo descritivo-exploratório e correlacional apropriou-se da abordagem quantitativa e teve como objetivo caracterizar e analisar o burn out de enfermeiros oncologistas , considerando suas relações com variáveis pessoais e ocupacionais. A população foi composta por 77 enfermeiros que atuavam em unidades de Oncologia clínica e cirúrgica de cinco hospitais do município de São Paulo. Foram utilizados, para a coleta de dados, três instrumentos: um inventário de dados demográficos e ocupacionais construído pela autora, o inventário de Burn out de Maslach e Jackson e o inventário de Coping de Folkman e Lazarus. Os resultados apontaram que 53,3% dos enfermeiros apresentavam algum sintoma de burn out, sendo 29,9% com alteração em uma das dimensões, 14,3% com alteração em duas dimensões e 9,1% com alteração nas três dimensões. Não foi verificada para a população estudada diferença estatisticamente significativa entre as variáveis demográficas e ocupacionais selecionadas com o burn out. Os principais estressores identificados pelos enfermeiros foram: o óbito, o relacionamento com a equipe médica e de enfermagem e as situações de emergência. Houve diferença, estatisticamente significativa, entre a dimensão incompetência profissional, o estressor óbito e a utilização do coping suporte social e fuga esquiva; e entre a dimensão desgaste emocional, relacionamento com equipe médica e de enfermagem e a utilização do coping fuga esquiva. Os enfermeiros utilizaram em maior proporção os estilos de coping resolução de problema e reavaliação positiva e, o estilo de coping menos utilizado, referiu-se à fuga esquiva / This descriptive exploratory and correlative study adopted the quantitative method and the aim was to characterize and analyse the burn out among oncology nurses regarding the relations with personal and occupational variables. The sample was represented by 77 nurses working in oncology clinical and surgical units in five hospitals in the city of São Paulo. Three tools were used for the data collect: a demographic and occupational inventory data made by the author, the Maslach and Jackson Burn out Inventory and the Folkman and Lazarus Coping Inventory. The results showed that 53,3% of the nurses demonstrated some kind of symptom of burn out, being 29,9% with alteration in one dimension, 14,3% with alteration in two dimensions and 9,1% with alteration in three dimensions. It wasnt verified in this sample any important statistic difference between the demographic and occupational variables and burn out. The main stressors identified by the nurses were the death and dying, the conflict with doctors and the nursing team and the emergency situations. There was a statistic difference between personal accomplishment dimension and the stressor death and dying and the copings social support and escape. Also between the emotional exhaustion dimension and the stressor conflict with doctors and nursing team and the coping escape. The nurses used more frequently problem solving and positive reappraisal as coping styles, and the less used was the act of escaping
|
335 |
O \"Ato de Cortar-se\": uma investigação psicanalítica a partir do caso Amanda e do caso Catarina / The Act of Self-Cutting: a psychoanalytical investigation based on the Amanda and Catarina clinical casesVenosa, Viviana Senra 15 October 2015 (has links)
Deparar com um sujeito que se corta pode ser, para quem inicia o percurso clínico, muito mobilizador. Uma convocação ao olhar acontece de maneira extremamente pungente. A pergunta que orienta esta pesquisa é: de que de modo o dispositivo analítico pode operar nessa tríade: olhar/palavra/elaboração? Para buscar responder, o recorte deste trabalho se estabeleceu a partir do material clínico de que dispúnhamos. Mais precisamente, abordamos o ato de cortar-se na sua apresentação em sujeitos neuróticos, mas outras investigações se fazem necessárias, por exemplo, quanto ao ato de cortar-se na psicose e na perversão. Até o presente momento, existe parca bibliografia específica sobre o ato de cortar-se em Psicanálise. Sendo assim, fizemos um breve apanhado sobre o tema na Psiquiatria, na Antropologia e na Sociologia. Também apresentamos o ato de cortar-se no seu contexto midiático, uma vez que a internet e as redes sociais são um dos meios pelos quais as pessoas que se cortam publicizam anonimamente seu sofrimento psíquico. Lançando mão da teoria freudiana, mostramos a importância de cunhar o termo ato de cortar-se do ponto de vista metapsicológico. E, depois, apresentamos dois casos clínicos, onde os conceitos de: angústia, acting-out e passagem ao ato, vistos por Freud e Lacan, se fizeram fundamentais para conduzir as análises dos casos. Com isso, esperamos contribuir para a ampliação de um campo de estudo sobre o tema / For those who are just starting clinical practice, coming across a subject who self-cuts can be very disturbing. The gaze is summoned very poignantly. The question that guides this research is: in what way can the analytical device operate in the gaze/ speech/ psychic elaboration triad? To answer this, the focus of this work is based on the clinical material at our disposal. More precisely, we approached the act of self-cutting as it presents itself in neurotic subjects. As this act also appears in psychosis and perversion, further investigations are necessary. In Psychoanalysis, there is scant literature on this specific act to date, so we did a brief survey on the topic in Psychiatry, Anthropology, and Sociology. We also present the act of self-cutting in the context of media, as self-cutters use the internet and social networks as a means to anonymously bring to public notice their psychological distress. Using Freudian theory, we show the importance of coining the term \"act of self-cutting\" from a metapsychological point of view. Afterwards, we present two clinical cases where the concepts of anguish, acting-out and passage to the act, as seen by Freud and Lacan, became fundamental in conducting the analyzes of these clinical cases. With this, we hope to contribute to the expansion of the field of study on the subject
|
336 |
Influência de diferentes protocolos de tratamento da dentina de raízes fragilizadas sobre a resistência de união de pinos fibrorreforçados: avaliação por meio de microscopia confocal, push-out e microdureza / Influence of different treatment protocols of weakened root dentin on the bond strength of glass fiber reinforced post: confocal microscopy, microhardness and push-out evaluationMoura, Altair Soares de 12 December 2014 (has links)
O presente estudo teve como objetivo avaliar, in vitro, a influência de diferentes protocolos de tratamento da dentina intrarradicular de raízes fragilizadas sobre a resistência de união (RU) de pinos fibrorreforçados fixados com diferentes cimentos resinosos. Quarenta e dois caninos superiores humanos tiveram suas raízes padronizadas em 17mm após eliminação das porções coronárias. O preparo biomecânico foi realizado por meio do sistema Reciproc, com instrumento R 50.05 e NaOCl 2,5%. As raízes foram fragilizadas por meio das brocas #4137 e #720G na profundidade de 12mm e obturadas pela técnica da condensação lateral com cimento AH Plus acrescido de Rhodamina B 0,1%. Decorrido 3 vezes o tempo de endurecimento a obturação foi removida e os pinos de fibra de vidro reembasados com resina composta. As raízes foram distribuídas em 3 grupos (n=14) conforme o tratamento da superfície dentinária: NaOCl 2,5%; NaOCl 2,5% + EDTA 17% e; NaOCl 2,5% + EDTA 17% + ultrassom. Em metade dos espécimes de cada grupo a cimentação do pino foi realizada com RelyX U200 e na outra, com Panavia F. Ambos cimentos foram acrescidos de fluoreceína 0,1%. As raízes foram seccionadas transversalmente obtendo-se dois slices de cada terço, um destinado ao teste de push-out e outro, à análise por meio do Confocal e mensuração da microdureza Knoop. Os dados foram submetidos ao teste ANOVA com parcela sub-dividida seguido do teste de Tukey (α=0,05). Os maiores valores de RU foram observados com o NaOCl + EDTA e NaOCl + EDTA + ultrassom (p>0,01) em relação ao NaOCl isolado (p<0,0001). A Panavia F apresentou maior RU que o RelyX U200 nos espécimes tratados com NaOCl + EDTA e NaOCl + EDTA + ultrassom (p<0,0001), nos três terços radiculares. Não houve diferença entre os materiais cimentantes nos espécimes tratados apenas com NaOCl (p>0,01). Os protocolos não influenciaram a RU do cimento RelyX U200. Em geral a maior incidência de falha foi do tipo adesiva (38,83%), seguido da mista (34,72%) e coesiva (26,45%). O tratamento da dentina com NaOCl + EDTA + ultrassom promoveu a maior redução da microdureza. Concluiu-se que o cimento resinoso Panavia F apresentou os maiores valores de RU nos três terços radiculares e que os protocolos não influenciaram a RU dos espécimes cimentados com RelyX U200 / The present study aimed to evaluate, in vitro, the influence of different treatment protocols of weakened root dentin on the bond strength (BS) of glass fiber reinforced post luted with different resin cements. Forty two upper human canines were sectioned and the root length was standardized on 17-mm after coronary portion was removed. Biomechanical preparation was performed via Reciproc system with R 50.05 instrument and 2.5% NaOCl. The roots were flared using diamond bur #4137 and #720G at a depth of 12mm and filled by the lateral condensation technique with AH Plus sealer modified with 0.1% Rhodamine B. After 3 times the time required to the setting reaction of the sealer the filling was removed and the glass fiber post was relined with composite resin. The roots were divided into 3 groups (n = 14) according to the treatment of dentin surface: 2.5%NaOCl; 2.5%NaOCl + 17% EDTAand 2.5% NaOCl+ 17% EDTA+ ultrasound. Half of the samples of each group had the post luted with RelyX U200 and the other half with Panavia F. Both cements were added with 0.1% fluorescein. The roots were transversely sectioned obtaining two slices of each third, one for the push-out test and the other for the confocal analysis and measurement of knoop hardness. Data were submitted to ANOVA test with sub-divided portion followed by Tukey test (α= 0.05). The highest BS values were observed for 2.5% NaOCl + 17% EDTA and 2.5%NaOCl + 17% EDTA + ultrasound (p> 0.01) compared to 2.5%NaOClalone (p <0.0001). Panavia F showed higher BS than RelyX U200 in specimens treated with 2.5%NaOCl + 17% EDTA and 2.5% NaOCl + 17% EDTA + ultrasound (p <0.0001) in the three root thirds. There was no difference between the luting materials in specimens treated only with 2.5% NaOCl(p> 0.01). The protocols did not affect the BS of RelyX U200. Overall the higher incidence of failure was adhesive (38.83%) followed by mixed (34.72%) and cohesive (26.45%) failure. Dentin treatment with 2.5%NaOCl+ 17% EDTA + ultrasound promoted the greatest reduction in microhardness. It was concluded that the Panavia F presented the highest BS in the three root thirds and the protocols did not influence the BS of the specimens filled with RelyX U200
|
337 |
Efeito do tratamento do canal radicular com EDTA na retenção de pinos de fibra de vidro / Effect of surface treatment with EDTA on bond strength of an fiber post systemGordillo, Luis Alfonso Arana 22 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:13Z (GMT). No. of bitstreams: 1
Luis Alfonso Arana Gordillo.pdf: 1025463 bytes, checksum: 5c067b2343a2b540759fb0b3f54a82f7 (MD5)
Previous issue date: 2010-02-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The purpose of this study was to analyze the effect of the treatment of dentin with EDTA on the bond strength of a fiber post to dentin, using two different types of resin cements. A total of 40 single canal, sound extracted human bicuspids were selected. After extraction the teeth were stored in water until use. Post spaces were prepared in extracted premolars and then the root canals were subjected to one of the following four groups (n = 10): Group 1 - self-adhesive cement RelyXTM U100, Group 2 - etching with 24% EDTA for 60 s before applying the cement RelyXTM U100, Group 3 - cementation as recommended by the manufacturer with Para Post® Para CoreTM Automix and self-etching adhesive, Group 4 - etching with 24% EDTA for 60 s before application of Para Post® Para CoreTM Automix cement and self-etching adhesive. The 10 roots per group were cut perpendicular to the long axis of the tooth in 6 slides 1 mm for push-out test (two slides for root third). After cutting one slide for each third was subjected to thermal cycling test of 5000 cycles at 5 º C and 55 ° C the slides were randomly divided into two subgroups, depending on testing time (imMédiate vs. termocycling ), for push-out test. The push out test was performed at a speed of 0.5 mm / min. Data were analyzed with a one-way analysis of variance (ANOVA) and Tukey HSD test. ANOVA revealed that canal surface treatment with EDTA 24% affected the bond strength negatively at the cervical third of the two cements, but did not alter the bond strength of dentin cements tested in the middle and apical thirds in the imMédiate group, the group of thermocycling was no significant difference when compared with the group imMédiately with or without EDTA 24% for all groups tested Para Post® Para CoreTM Automix and self-etching adhesive showed higher bond strength values when compared with RelyXTM U100 resin cement. It was concluded that treatment with EDTA did not affect the bond strength except at the cervical third , EDTA 24% did not alter the of bond strength values in the groups of thermocycling test, the Para Post® Para CoreTM Automix and self-etching adhesive cement had better performance when compared with cement RelyXTM U100. / A proposição deste estudo foi analisar o efeito do tratamento da dentina radicular com EDTA na retenção de pinos de fibra de vidro utilizando dois tipos diferentes de cimentos resinosos. Foram utilizados 40 dentes humanos pré-molares hígidos. Após a extração os dentes foram armazenados em água até seu uso. Em seguida, os dentes foram tratados endodonticamente com técnica step back para ser obturados por condensação lateral com cones de guta percha e cimento endodôntico AH Plus. Após a obturação os dentes foram cortados perpendicularmente ao longo eixo do dente 2 mm acima da linha cemento esmalte e divididos em quatro grupos (n=10): grupo 1 - cimento autoadesivo RelyXTM U100; grupo 2 - condicionamento com EDTA 24% por 60 s antes da aplicação do cimento RelyXTM U100; grupo 3 - cimentação segundo as recomendações do fabricante com Para Post® Para CoreTM Automix e adesivo autocondicionante Para Bond e grupo 4 - condicionamento com EDTA 24% por 60 s antes da aplicação do cimento Para Post® Para CoreTM Automix e adesivo autocondicionante Para Bond. As 10 raízes por grupo foram cortadas perpendicularmente ao longo eixo do dente em 6 discos de 1 mm para teste de push out (dois discos por terço radicular). Após o corte um disco por cada terço foi submetido ao teste de termociclagem 5000 ciclos 5º C e 55º C obtendo assim um disco de cada terço submetido a teste de push out iMédiato e o disco restante foi submetido a teste de push out após a fadiga térmica o teste de push out foi realizado a uma velocidade de 0,5 mm/min. Após o teste os dados foram analisados estatisticamente com o teste de ANOVA e pos teste de Tukey dando como resultado que o tratamento de superfície dentinária com EDTA 24% alterou negativamente os valores de resistência de união para o terço cervical dos dois cimentos, mas não alterou a resistência de união a dentina dos cimentos testados nos terços médio e apical no grupo iMédiato, para o grupo de termociclagem não houve diferença significativa quando comparado com o grupo iMédiato com ou sem aplicação do EDTA 24%, para todos os grupos testados o cimento Para Post® Para CoreTM Automix obteve maiores valores de resistência de união quando comparado com o cimento RelyXTM U100. Concluiu-se que o tratamento com EDTA não afetou os valores de resistência de união exceto para o terço cervical; o EDTA 24% não alterou os valores de resistência de união nos grupos submetidos ao teste de termociclagem; o cimento Para Post® Para CoreTM Automix teve melhor comportamento quando comparado com o cimento RelyXTM U100.
|
338 |
Influência de diferentes técnicas obturadoras na força de união de materiais obturadores à dentina intrarradicular / Influence of techniques obturation in bond strength of endodontic materials in dentin intrarradicularNhata, Juliane 24 January 2012 (has links)
Neste estudo avaliou-se, in vitro, por meio do teste de Push Out, a influência das técnicas obturadoras, condensação lateral, McSpadden modificada e sistema Beefill, na adesividade dos materiais obturadores em canais achatados. Foram utilizados 40 incisivos inferiores instrumentados com o sistema rotatório Hero de acordo com a técnica Free Tip (Pécora, et al., 2002), utilizando como solução irrigante o hipoclorito de sódio a 1%, alternado com EDTA a 17% e irrigação final com água destilada, para os grupos I, II E IV. Para o grupo III, foi utilizado somente soro fisiológico, e este serviu como o grupo controle. Após o preparo de acordo com as soluções irrigantes os dentes, foram distribuídos aleatoriamente em quatro grupos (n=10), de acordo com o sistema de obturação: GI - condensação lateral, GII - Beefill, GIII - condensação lateral (controle) e G IV - McSpadden modificada Os grupos foram obturados com o cimento resinoso AH Plus. Após esse processo, cada raiz foi seccionada transversalmente de modo a se obter seis corpos-de-prova de aproximadamente 1,0 mm de espessura, que foram submetidos ao teste de Push Out, em Máquina Universal de Ensaios (Instron 3345). Os dados de tensão (MPa) foram submetidos à análise estatística de Kruskal Wallis e o teste de Tukey. Os resultados demonstraram diferença estatisticamente significante (p<0,05) entre as técnicas de obturação. A técnica de condensação lateral obteve os maiores valores de tensão (3,98±2,03), seguido pela técnica de McSpadden modificada (3,44±1,73), controle (2,62±1,34) e Beefill (2,16±1,10). Pode-se concluir que a força necessária para o deslocamento do material obturador dos dentes obturados com a técnica de condensação lateral foi maior quando comparada com as demais técnicas. A técnica de McSpadden apresentou um comportamento intermediário ora pertencendo ao grupo da condensação lateral e ora ao grupo controle, já o Beefill, foi à técnica que se apresentou com os menores valores para o deslocamento do material obturador. O grupo controle situou-se numa condição também intermediaria podendo pertencer tanto ao grupo da Beefill quanto da McSpadden. Em relação aos terços, a porção apical foi a que apresentou os maiores valores em relação aos dois outros terços, que são estatisticamente semelhantes. A análise da microtomografia evidenciou que o sistema Beefill teve um melhor comportamento em relação ao preenchimento do canal radicular, seguido na ordem pela McSpadden modificada, condensação lateral e controle. / This study evaluated in vitro by means of the Push Out the influence of the obturation techniques, lateral condensation, Mc Spadden modified, Beefill system and in adhesion of filling materials in flat canals. Forty mandibular incisors were instrumented with the rotary system of Hero according to technique Free Tip (Pécora, et al., 2002), as irrigating solution using sodium hypochlorite 1% alternating with 17% EDTA and final irrigation with distilled water, for groups I, II and IV. For Group III, only saline solution was used, and this served as the control group. After preparation according to the irrigating solutions teeth were randomly divided into four groups (n = 10), according to the shutter system: GI - lateral condensation, GII - Beefill, GIII - lateral condensation (control) and G IV - McSpadden modified. The groups were filled with AH Plus resin cement. After this process, each root was sectioned transversely so as to obtain six sample of approximately 1.0 mm thick, which was tested using the Push Out in a universal testing machine (Instron 3345). The data of stress (MPa) were statistically analyzed using Kruskal Wallis and Tukey\'s test. The results showed statistically significant difference (p <0.05) between the techniques of filling. The lateral condensation technique achieved the highest voltage (3.98 ± 2.03), followed by McSpadden modified technique (3.44 ± 1.73), control (2.62 ± 1.34) and Beefill (2.16 ± 1.10). It can be concluded that the force required for displacement of the filling material of the teeth obturated with lateral condensation technique was higher compared with other techniques. The technique of McSpadden presented an intermediate behavior belonging to either the lateral condensation group and either control group. Befilll, the technique was performed with the lowest values for the displacement of the filling material. The control group was situated in an intermediate condition also can belong to both the group Beefill and McSpadden. Regarding thirds, the apical portion showed the highest values in relation to the other two thirds, which are statistically similar. The analysis showed that microtomography system Beefill had a better behavior in relation to filling the root canal, followed in order by McSpadden modified lateral condensation and control.
|
339 |
Determinação de benzidina nos rios que recebem a carga de efluentes das industrias têxteis da cidade de São Carlos / Determinación de la bencidina en los rios que reciben la carga de efluentes de las industrias textiles de la ciudad de São CarlosArruda, Flávio Roberto 26 September 2008 (has links)
Estima-se que cerca de 12% dos corantes sintéticos têxteis se perdem entre os processos de produção e utilização, sendo dificil a avaliação do impacto gerado pela industria de manufatura ao meio ambiente. A benzidina, um composto reconhecidamente cancerígeno e mutagênico está presente em algumas centenas de composições de tintas listadas no color index. Apesar de muitos paises proibirem o uso da benzidina, como é o caso dos EUA que desde 1973 só permitem a sua produção para consumo próprio das empresas produtoras, países como o Brasil não possuem um controle tão eficiente da produção e uso de corantes a base de benzidina, sendo encontrada até mesmo em medicamentos de uso pediátrico. Optou-se por verificar a presença de benzidina nos córregos do Tijuco Preto e do Gregório porque em São Carlos existem duas industrias têxteis que dispõe os seus efluentes nos mesmos. Neste trabalho foi empregado o método de extração líquido-líquido em pH 9,5 para a determinação da benzidina em amostras de água. Foi utilizada a cromatografia gasosa acoplada a espectrometria de massas para detectar e quantificar a benzidina nas amostras de água dos córregos do Tijuco Preto e do Gregório. Foi verificada a presença de benzidina nas amostras de água do córrego do Tijuco Preto e do córrego do Gregório nas concentrações da ordem de 0,0007 e 0,0006 mg L-1 respectivamente. / It is estimated that approximately 12% of synthetic textile dyes are lost between production and use, which makes the evaluation of the environmental impact of the textile industry difficult. Benzidine is a recognized carcinogen and mutagen, which can be found in a wide variety of dyes listed in the Color Index. A number of countries have banned the use of benzidines. This is true for USA (1973), which only permits production of benzidine for a companys own consumption. However, countries like Brazil do not have such an efficient control over the production and use of benzidine-based dyes, which can even be found in pediatric medicines. In this study, the presence of benzidines in the Tijuco Preto and Gregório streams (São Carlos city) was verified. These waterways were chosen due to the fact that two textile industries discharge their wastewater into these watercourses. In this study the liquid-liquid extraction method at pH 5 was employed for sample preparation and gas chromatography coupled with a mass spectrometer (GC-MS) was used to detect and quantify benzidines in the collected water samples. The presence of benzidines was verified in both the Tijuco Preto and Gregório streams at concentrations of 0.0006 and 0.0007 mg L-1, respectively.
|
340 |
Investigação da durabilidade do benefício gerado pela Educação Infantil / Investigating the durability of the early childhood education\'s effectsFonseca, Gabriela do Couto 07 May 2015 (has links)
A literatura internacional ao investigar a durabilidade dos efeitos do Ensino Infantil se deparou com um eventual fenômeno de decaimento de tais efeitos, chamado de facing-out. Utilizando dados longitudinais coletados na cidade de Sertãozinho buscamos investigar e documentar tal fenômeno para a realidade nacional. Encontramos evidências de decaimento do benefício do EI especialmente sobre a proficiência de matemática. Além disso, mostramos que a estrutura da base de dados utilizada para fazer tal mensuração pode gerar resultados sobrestimados, especialmente se tal base contiver alto grau de seletividade. Por fim, indicamos que a qualidade das instituições de educação na primeira infância pode ser um dos determinantes da durabilidade do efeito encontrado, uma vez que crianças que frequentaram a maior parte do EI em escolas públicas estão mais sujeitas a este fênomeno. / The international literature while investigating the long term effects of early childhood education identified a decrease phenomenon of such effects, called fading-out. Using longitudinal data collected in the city of Sertãozinho our goal was to investigate and document this phenomenon for Brazilians\' reality. We found evidence of the decrease of early childhood education benefits, especially in Math proficiency. Furthermore, we show that the structure of the database used to make such measurements can generate results that overestimate the phenomenon, especially if those databases contain a high degree of selectivity. Finally, we indicate that the quality of the early childhood schoolscan be an important determinant of the effects\' durability, since children who attended most of the early childhood education in public schools are more prone to this phenomenon.
|
Page generated in 0.0356 seconds