• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 404
  • 261
  • 126
  • 61
  • 29
  • 26
  • 19
  • 16
  • 12
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 1209
  • 234
  • 181
  • 181
  • 142
  • 124
  • 105
  • 98
  • 92
  • 91
  • 90
  • 73
  • 73
  • 71
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
591

Ascensão e queda dos CFCs: uma análise de periódicos científicos e de livros didáticos de química ambiental / Rise and fall of CFCs: an analysis of scientific journals and environmental chemistry textbooks

Helio Elael Bonini Viana 27 August 2013 (has links)
O presente trabalho tem como objetivo investigar os processos de ascensão e queda dos clorofluorocarbonetos (CFCs) como bens de consumo, bem como o desenvolvimento da percepção de risco da comunidade química em relação a esses compostos, que culminou com sua caracterização como agentes de risco ambiental global. Para isso, foi desenvolvido um estudo de caso histórico acerca do uso dos CFCs ao longo do século XX, de solução tecnológica ideal a protagonista de uma inédita dimensão de risco químico. Além disso, foi realizada uma análise de cartas enviadas por leitores, editoriais e resenhas de livros publicadas em cinco periódicos científicos: Chemical & Engineering News, Journal of Chemical Education, Environmental Science and Technology, Nature e Science, no período compreendido entre 1975 e 1991, e de livros didáticos de Química Ambiental publicados entre 1970 e 1995 - período marcado por intenso debate sobre a possibilidade de destruição da camada de ozônio estratosférica. A escolha desses periódicos e livros buscou contemplar diferentes seções da comunidade química, de modo a se ter uma amostra representativa de diferentes formas de pensamento dentro desse amplo espectro profissional que constitui a química. Para análise dessa amostra foi escolhida a Teoria Cultural de Douglas e Wildavsky, a qual descreve quatro visões de mundo que se mostram bastante adequadas para analisar as percepções de risco, as atitudes e os argumentos envolvidos nas discussões da época. Os resultados obtidos apontam para mudanças nas percepções de risco da comunidade química, aproximando-as do Princípio da Precaução para a tomada de decisões, em um período marcado pelo desenvolvimento da Química Ambiental. / This study aims to investigate the processes of rise and fall of chlorofluorocarbons (CFCs) as consumer goods, as well as the development of risk perception regarding these compounds among the chemists community, culminating in its characterization as agents of global environmental risk. A historical case study on the trajectory of CFCs throughout the twentieth century, from ideal technological solution to protagonist of an unprecedented scale chemical risk, was developed. In addition, the study includes an analysis of letters from readers, editorials and book reviews published in five journals: Chemical & Engineering News, Journal of Chemical Education, Environmental Science and Technology, Nature and Science, in the period between 1975 and 1991, and also an analysis of Environmental Chemistry textbooks published between 1970 and 1995 - a period marked by intense debate about the possibility of destruction of the stratospheric ozone layer. The choice of these journals and books sought to include different sections of the chemistry community, in order to get a representative sample of different ways of thinking within the broad professional spectrum of chemistry. Douglas\' and Wildavsky\'s Cultural Theory was selected to analyse this sample. The theory describes four worldviews that seems rather appropriate to analyze risk perceptions, attitudes and arguments involved in the discussions of the time. Results point to changes in chemists\' risk perceptions, which brought them closer to the Precautionary Principle as a guide to decision making in a period marked by the development of Environmental Chemistry.
592

Tratamento combinado de lixiviado de aterro sanitário e esgoto doméstico utilizando ozônio

Schons, Alisson 24 February 2016 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-25T11:43:55Z No. of bitstreams: 1 Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5) / Made available in DSpace on 2017-05-25T11:43:56Z (GMT). No. of bitstreams: 1 Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5) Previous issue date: 2016-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / UNISINOS - Universidade do Vale do Rio dos Sinos / O lixiviado de aterro sanitário tem se caracterizado pela alta concentração de matéria orgânica recalcitrante, nitrogênio amoniacal e compostos tóxicos. Compostos orgânicos recalcitrantes são raramente removidos por processos tradicionais de tratamentos de efluentes, o que dificulta o atendimento aos padrões de lançamento de efluentes. Da mesma forma, o descarte do esgoto doméstico gerado pelas comunidades precisa também de tratamentos prévios para não impactar o meio ambiente. Devido às características do esgoto doméstico, com baixas concentrações de matéria orgânica carbonácea e cor em relação ao lixiviado, vem permitindo que o tratamento combinado desses efluentes seja uma alternativa viável. Diante desse quadro, este trabalho visou à avaliação do tratamento combinado de esgoto doméstico da estação de tratamento de efluentes (ETE) da Unisinos e lixiviado bruto do aterro sanitário de São Leopoldo, utilizando ozônio (O3) como agente oxidante. Os efluentes foram tratados na unidade experimental composta por um reservatório com capacidade de até 500L e um reator cilíndrico de PVC com 250 mm de diâmetro e 2,20 m de altura, operando com fluxo ascencional, totalizando um volume de trabalho de 108 L e preenchido em 2/3 do seu volume total com Anel Pall de 1,5”. Realizaram-se três ensaios em bateladas, com duração de cinco horas e três ensaios com duração de duas horas, com diferentes produções de O3 de 8,9; 9,6 e 10,5 g de O3.h-1, aplicados à mistura de 2% de lixiviado de aterro sanitário (LAS) ao esgoto doméstico (2 L de LAS e 158 L de esgoto). Cada ensaio foi realizado em duplicata, sendo monitorados os seguintes parâmetros: Demanda Química de Oxigênio, Demanda Bioquímica de Oxigênio, Cor Aparente e Verdadeira, Turbidez, pH e calculada as taxas de utilização e de perda de O3. Os resultados evidenciaram que o tratamento por O3 pode ser uma alternativa de pré-tratamento de efluentes, obtendo remoções médias de DQO, DBO, CA, CV e Turbidez de até 46%, 51%, 86%, 86% e 81% respectivamente em cinco horas de ensaio e remoções médias de até 23%, 48%, 78%, 76% e 58% respectivamente em duas horas de ensaio. As maiores taxas de remoções foram alcançadas nos ensaios com maiores vazões de O2 e produções de O3 e nas duas primeiras horas de ensaio. Só foi possível o atendimento aos padrões de lançamentos de efluentes exigidos pela legislação vigente, nos ensaios com duração de cinco horas e com a maior produção de O3 e vazão de O2. O sistema de tratamento também contribuiu para uma melhora na biodegradabilidade do efluente se analisada a relação DBO/DQO e cor. Quanto as taxas de utilização e de perda de O3, verificou-se que a maior quantidade consumida de O3, ocorreu para os parâmetros indicativos de matéria orgânica e para os ensaios com a menor produção de O3. / Landfill leachate has been characterized by the high concentration of recalcitrant organic matter, ammoniacal nitrogen and toxic compounds. Recalcitrant organic compounds are rarely removed by traditional effluent treatment processes. In addition, the treatment of the leachate is colloquial to meet the discharge standards of the effluent. Likewise, the domestic sewage disposal generated by the communities also needs previous treatments to avoid impacts on the environment. Due to the characteristics of domestic sewage, with low concentrations of organic carbon in relation to the leachate, it has allowed the combined treatment of these effluents to be a viable alternative. In view of this situation, this work had the objective of evaluating the combined treatment of domestic sewage of (ETP) and the raw leachate of the San Leopoldo landfill using ozone (O3) as an oxidizing agent. Three batch trials were carried out with a scheduled duration of five hours and three trials lasting two hours, with different yields of O3 of 8.9, 9.6 and 10.5 g of O3.h-1, applied to the mixture Of 2% of landfill leachate) For domestic sewage (2L of LAS and 158L of sewage). Each assay was performed in duplicate and the following parameters were monitored: Oxygen Chemical Demand, Biochemical Oxygen Demand, Apparent and True Color, Turbidity, pH and calculated O3 utilization and loss rates. The results showed that the treatment with O3 can be an excellent alternative of pretreatment of effluents, obtaining average removals of COD, BOD, CA, CV and Turbidity of up to 46%, 51%, 86%, 86% and 81 % Respectively. Average test and removal hours of up to 23%, 48%, 78%, 76% and 58%, respectively, in two hours of testing. The highest removal rates were obtained in the tests with higher flows of O2 and yields of O3 and in the first two hours of the test. It was only possible to meet the effluent release standards required by current legislation, in trials with a duration of five hours and with the highest production of O3 and O2. The treatment system also contributed to an improvement in the biodegradability of the effluent if the BOD/COD ratio was analyzed. As for the rates of use and loss of O3, it was verified that the highest amount of O3 occurred for the parameters indicative of organic matter and for the tests with lower production of O3. The higher the O3 production, the higher the O3 loss and the greater oxidant loss may have been due to volatilization in the effluent accumulation reservoir, since there was no gas loss due to Off-gas and the method used Not Detected The residual ozone.
593

Avaliação in vitro da associação do efeito antimicrobiano do ozônio associado a veículos e curativos de demora em diferentes períodos de tempo de armazenagem /

Ortega Cruz, Hernan Freddy. January 2006 (has links)
Resumo: No presente trabalho de pesquisa se fez uma Avaliação in vitro da capacidade de associação do efeito antimicrobiano do ozônio a veículos: óleo de oliva, óleo de girassol e propilenoglicol, e curativos de demora: Calen, Calen PMCC e propilenoglicol mais hidróxido de cálcio nos períodos de um, sete, quinze, trinta e cento e oitenta dias, após de submetidos a um processo de ozonização por borbulhagem, mediante a técnica de sensibilidade a os antimicrobianos (difusão em ágar e mensuração de halo de inibição em culturas de bactérias) utilizando como bactérias indicadoras a "P. aeruginosa e E. faecalis". As bactérias foram semeadas em 3 placas de Petri cada, fazendo um total de 6 placas cultivadas por tempo de avaliação. foram feitos leitos para alojar os materiais testados. Após 48 horas, para cada tempo avaliado, analisamos os halos de inibição formados. Baseado nos resultados pode-se concluir que os curativos de demora Calen e o Calen PMCC, não tem associação sinérgica com o ozônio, mas possuem atividade antimicrobiana própria e estabilidade no tempo. O óleo de girassol tem maior capacidade de associação com o ozônio que o óleo de oliva e ambos têm estabilidade no tempo e ação antimicrobiana maior sobre a E. faecalis. 0 propilenoglicol tem boa capacidade de associação com o ozônio e estabilidade no tempo, mantendo a atividade antimicrobiana. O propilenoglicol mais hidróxido de cálcio tem menor capacidade de associação com o ozônio que o propilenoglicol e maior capacidade de associação que o óleo de girassol possuindo ação antimicrobiana e estabilidade no tempo. / Abstract: In this investigation in vitro evaluation of association of the antimicrobial effect of ozone to vehicles olive oil, sunflower oil and propilenoglicol and temporary root canal medication Calen, Calen plus PMCC and propilenoglicol plus calcium hydroxide after one, seven, fifteen, thirty and one hundred and eighty days post-ozonated, by means of sensibility antimicrobial technique (inhibition halo measure) with P. aeruginosa and E. faecalis. Bacterium where placed in 3 Petri plaques totalizing 6 plaques for evaluation period. Eleven holes where done and material inserted. After 48 hours, inhibition halos where analyze, for each evaluated period. We conclude that the Calen and Calen plus PMCC have no association with ozone, but have antimicrobial activity and last all the period. Sunflower oil has the greater association with ozone than the olive oil, both stability and antimicrobial action against E. faecalis. Propilenoglicol has the greater association with ozone and stability in time, keeping antimicrobial activity. Propilenoglicol plus calcium hydroxide has less association with ozone than propilenoglicol and association affinity than sunflower oil with antimicrobial action and stability in time. / Orientador: Idomeu Bonetti Filho / Coorientador: Antonio Carlos Pizolitto / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Alexandre Augusto Zaia / Mestre
594

Avaliação do efeito bactericida do ozônio associado ao propilenoglicol em canais radiculares contaminados com enterococcus faecalis em diferentes períodos de tempo de armazenagem /

Farac, Roberta Vieira. January 2010 (has links)
Resumo: O presente estudo avaliou, ex vivo, atividade antimicrobiana do ozônio, associado ao veículo propilenoglicol e ao hidróxido de cálcio em canais radiculares contaminados com Enterococcus faecalis. Foram utilizados 50 dentes humanos unirradiculados, doados pelo Banco de Dentes da Faculdade de Odontologia de Araraquara. Após remoção das coroas dentárias, os canais radiculares foram instrumentados até uma lima endodôntica tipo kerr de número 50, e em seguida, os espécimes foram esterilizados, e os canais radiculares contaminados com E. faecalis e incubados a 37 ± 1°C por 21 dias. Os espécimes foram aleatoriamente divididos em cinco grupos experimentais, de acordo com a medicação utilizada: GI - Ozônio com propilenoglicol (n=11); GII - hidróxido de cálcio com paramonoclorofenolcanforado - PMCC (n=11), GIII - propilenoglicol com pó de hidróxido de cálcio ozonizado (n=11), GIV - grupo controle positivo - não foi colocada nenhuma medicação (n=11) e GV - grupo controle negativo - não foram contaminados (n=6). As coletas foram realizadas coletas após sete e quatorze dias e o crescimento microbiano verificado por meio da contagem de unidades formadoras de colônia (UFC) de E. faecalis. Os resultados que foram submetidos ao teste não paramétrico de Kruskal-Wallis, seguido pelo teste de Dunn e também pelo teste nãoparamétrico de Friedman sendo ambos com um nível de significância de 0,05, mostraram que o propilenoglicol ozonizado e o hidróxido de cálcio com PMCC reduziram estatisticamente o número de bactérias quando comparados ao grupo controle positivo em 7 e 14 dias, não apresentando diferenças estatísticas entre eles; o hidróxido de cálcio ozonizado não reduziu estatisticamente o número de bactérias quando comparados ao grupo controle positivo em 7 e 14 dias e o propilenoglicol ozonizado e o hidróxido de cálcio PMCC não apresentaram diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated in vitro bactericidal effect of ozone associated with the vehicle propylene glycol and calcium hydroxide in root canals contaminated with Enterococcus faecalis. It used 50 single-rooted human teeth, donated by the teeth of the Faculty of Dentistry of Araraquara. After removal of dental crowns, root canals were instrumented to an endodontic kerr file number 50, and then the specimens were sterilized, and the root canals contaminated with Enterococcus faecalis and incubated at 37 ± 1 ° C for 21 days. The specimens were randomly divided into five experimental groups, according to the medication used: GI - ozone with propylene glycol (n = 11), group II - calcium hydroxide with paramonoclorofenolcanforado - PMCC (n = 11), GIII - propylene glycol added powder calcium hydroxide ozoized (n=11), GIV - positive control group - was not placed any medication (n = 11) and GV - negative control group - were not infected (n = 6). Microbiological samples were collected after seven and fourteen days and the microbial growth observed at the count of the number of colony forming units of E. faecalis. The results were analyzed using the nonparametric Kruskal-Wallis followed by Dunn's test and also by the non-parametric Friedman and both with a significance level of 0.05, showed that the propylene ozonized and calcium hydroxide with PMCC statistically reduced the number of bacteria when compared to positive control group at 7 and 14 days, calcium hydroxide ozonized not statistically reduced the number of bacteria when compared to positive control group at 7 and 14 days and propylene ozonized calcium hydroxide and CMCP showed no statistically significant differences in bacterial growth at 7 and 14 days.In a descending order of bactericidal action in the two study periods, is calcium hydroxide PMCC, followed by propylene ozonized and ozonized calcium hydroxide / Orientador: Idomeo Bonetti Filho / Coorientador: Antonio Carlos Pizzolitto / Banca: Marco Antonio Húngaro Duarte / Banca: Juliane Maria Guerreiro Tanomaru / Mestre
595

The Relevance of Citations : a case of study of stratospheric ozone monitoring

Philipson, Joakim January 1996 (has links)
A contextual citation analysis was performed on a sample of 68 articles citing either or both oftwo key papers from the research field of stratospheric ozone monitoring.The theoretical approach of each article was assessed as either chemical or dynamical, or wasleft unspecified. Functions of citations to the two key papers were classified into 13 categories,seen to express various kinds of relevance relationships. Topical relatedness between citedand citing articles was studied in terms of number of shared descriptors and the union overlapmeasure. A certain theory~dependence, in the sense of a relatively high degree of correspondence between the theoretical approach of citing and cited articles, was observed in the material. The correlation between topical relatedness and citation relationships appeared to beweak.
596

Desenvolvimento e estudo de um sistema para tratamento de fenol e poluentes orgânicos emergentes (POE) por processos oxidativos avançados (POA) utilizando ozônio, peróxido de hidrogênio e radiação ultravioleta / Development and study of a system for the treatment of phenol and emerging organic pollutants (EOP) by advanced oxidation processes (AOP) using ozone, hydrogen peroxide and ultraviolet radiation

Nolasco, Felipe Rufine 29 April 2014 (has links)
O estudo avaliou a efetividade de um sistema para tratamento de soluções aquosas contendo poluentes orgânicos emergentes (POE), denominados interferentes endócrinos (IE). Baseado nos processos oxidativos avançados (POA), empregando ozônio, radiação UV, peróxido de hidrogênio e variação de pH, o estudo possibilitou determinar a relação ideal oxidante/poluentes e o custo/benefício dos tratamentos com melhores desempenhos, de degradação do padrão contendo hormônios 17?-estradiol (E2) e 17?-etinilestradiol (EE2), e outra contendo atrazina (ATZ). Para os estudos, foi utilizado um planejamento fatorial 23, para identificar as melhores opções de degradação. Os tratamentos iniciaram com soluções em concentrações de 600 ?g L-1 de ATZ, em quadruplicatas, por períodos de até 10 minutos. Posteriormente a avaliação dos melhores tratamentos, foi estudada a cinética de mineralização de soluções a 5 mg L-1 de ATZ, em até 90 min. A concentração de estudo adotada para os hormônios foi de 1 mg L-1. A determinação da ATZ e dos hormônios (E2 e EE2) foi realizada por cromatografia em fase líquida (CLAE), utilizando a extração em fase sólida (EFS) quando necessário. Para o estudo foram construídos dois sistemas de tratamento paralelamente acoplados (S1 - escala laboratorial e S2 - escala piloto), com os respectivos volumes de 0,43 L e 20 L. O S2 possibilitou a avaliação da degradação e/ ou mineralização do fenol em solução a 50 mg L-1, porém em escala 60 vezes superior ao S1. As eficiências das mineralizações da ATZ e do fenol, foram avaliadas pela análise de Carbono Orgânico Total (COT). As condições experimentais pré-estabelecidas foram: (i) UV-C 254 nm, variando entre 0, 16 e 32 W; (ii) H2O2 entre 0, 50 e 100% do total teórico necessário para mineralização dos poluentes; (iii) O3 (4,6 g h-1) e (iv) pH 7; 9 e 11, previamente aplicadas às soluções estoque de ATZ. Após avaliação da melhor combinação para degradação, optou-se por trabalhar, nos demais estudos, apenas com soluções em pH 11,0. Na última etapa deste estudo, foram desenvolvidos dois métodos (direto e indireto) para avaliar a geração do gás ozônio em tempo real, possibilitando também realizar a medição do consumo de O3 durante os estudos. Para avaliar a eficiência dos métodos, os resultados analíticos foram convertidos em % de degradação ou mineralização e os custos dos tratamentos foram estimados. Comprovando a viabilidade desta proposta, resultados envolvendo o tratamento de solução padrão de atrazina (600 ?g L-1) apresentaram, nas melhores condições (pH 11, 30 mg L-1 de H2O2 e 4,6 g L-1 de O3), eficiência igual ou superior a 95% (<LQ) na degradação do herbicida, em apenas 2,5 minutos de tratamento e posteriormente soluções a 5 mg L-1, apresentando até 100% de mineralização em 90 minutos. Quanto aos hormônios foram obtidos poucos resultados acima do LD do equipamento, porém todos ficaram abaixo do LQ (50 ?g L-1). Quanto ao fenol (50 mg L-1), estudado no sistema piloto (S2), atingiu-se até 80% de mineralização em 24 horas e 100% de degradação. Os resultados obtidos demonstram que os sistemas apresentaram excelente eficácia conforme esperado / The study evaluated the effectiveness of a system for treatment of aqueous solutions containing emerging organic pollutants (EOP), called endocrine disruptors (ED). Based on advanced oxidation processes (AOP) using ozone, UV radiation, hydrogen peroxide and pH variation. This study allowed the determination of the ideal oxidant/pollutants ratio and the cost/benefit of treatments with better performance, regarding the degradation of the pattern containing hormones 17?-estradiol (E2) and 17?-ethinylestradiol (EE2), and another containing atrazine (ATZ). A 23 factorial design was used in the study to identify the best options for degradation. The treatments were started with solutions at concentrations of 600 ?g L-1 ATZ, in quadruplicate, for periods up to 10 min. Subsequently to the best treatment evaluation; the degradation of 5 mg L-1 ATZ solutions was evaluated, within 90 min. The adopted study concentration of the hormones was 0,05 mg L- 1 and 1,0 mg L- 1. The determination of the ATZ and hormones (E2 and EE2) was performed by liquid chromatography (HPLC) using solid phase extraction (SPE) when necessary. For this study, two parallel coupled processing systems were constructed (S1 - Laboratory scale and S2 - pilot scale) with the respective volumes of 0.43 L and 20 L. S2 system was developed to enable evaluation of the degradation of an already known substance, 50 mg L-1 phenol solution, but on a scale 60 times greater than S1. The efficiency of ATZ and phenol mineralization was evaluated by Total Organic Carbon (TOC). The pre-established experimental conditions were: (i) 254 nm UV-C, varying among 0, 16 and 32 W, (ii) H2O2 among 0, 50 and 100% of the theoretical value needed to complete mineralization of the pollutant, (iii) O3 (4,6 g h-1) and (iv) pH 7; 9 and 11 previously applied to all stock solutions. After assessing the best combination for degradation, it was chosen to work in the other experiments only solutions with pH 11.0. In the last stage of the study, two methods (an electric and a spectrophotometric) were developed to assess the ozone gas generation in real time and also allowing the measurement of O3 consumption during the studies. To evaluate the efficiency of the methods, analytical results were converted to % degradation or mineralization and treatment costs were estimated. Proving the feasibility of this proposal, preliminary results involving the treatment of atrazine standard solution (600 ?g L-1) had, in the best conditions (pH 11, 30 mg L-1 of H2O2 and 4,6 g L-1 of O3), efficiency equal or superior to 95% (<LQ) in degradation of the herbicide in just 2.5 minutes of treatment and then 5 mg L-1 solutions had 100% mineralization in 90 minutes. To hormones, few results above the DL of the equipment were obtained, but all were below the QL of the equipment (50 mg L-1). When phenol (50 mg L-1) was studied in the pilot system it reached up to 80% of mineralization within 24 hours. The obtained results shown that the systems developed reached high efficiency for treating the pollutants
597

Cinética da redução de cor ICUMSA em caldo de cana-de-açúcar por ozonização em reator RPA/CSTR para produção sulfur-free de açúcar branco / Kinetics ICUMSA color reduction in juice sugarcane by ozonation reactor in RPA/CSTR to produce sulfur-free white sugar

Corrêa Nathalia Torres 11 February 2016 (has links)
A clarificação do caldo de cana-de-açúcar consiste em uma das etapas mais importantes dentro de todo o processo de produção de açúcar, isso porque, é a cor do açúcar final que determina seu preço de comercialização no mercado, bem como sua qualidade. Porém, além de ter um processo de redução de cor, que ao final apresente um açúcar de qualidade, é necessário que este processo não gere resíduos, nem para o meio ambiente, nem nenhum resíduos tóxicos que esteja presente no produto final e que venha prejudicar a saúde do consumidor. Desta forma, a busca por processos alternativos à sulfitação - que é a atual operação de clarificação do caldo de cana-de-açúcar na produção de açúcar cristal branco - tornou-se mais frequente. Tais processos são conhecidos como processos oxidativos avançados(POA) e, entre eles está o uso de ozônio. Diante deste cenário avaliaram-se as melhores condições de pH, temperatura e dosagem de ozônio para a redução da cor ICUMSA do caldo de cana-de-açúcar, obtendo como condições ótimas para pH entre 1,64 a 5,0, temperaturas de 50 a 70 °C e dosagens de ozônio entre 1,34 mg O3/min a 3,82 mg O3/min. O estudo cinético da redução da cor ICUMSA do caldo de cana-de-açúcar ozonizado permitiu observar maiores reduções de cor ICUMSA após 60 min de reação, contudo a exposição do caldo a longos períodos, em pH baixos (1,64 e 3,0) associados a altas temperaturas (50 e 70 °C) levou a hidrólise da sacarose em glicose e frutose, o que inviabilizaria o processo. As análises por espectrometria de massas permitiram observar que a redução nos teores de cor ICUMSA das amostras de caldo de cana-de-açúcar ozonizadas não está associadaà eliminação das partículas promotoras de cor, mas sim da precipitação destas partículas, uma vez que não foram identificados novos compostos nas amostras analisadas, mas sim umavariação nas concentrações destes compostos, identificados como lipídios. Além de favorecer a redução da cor ICUMSA do caldo, o ozônio também se apresentou como um agente antimicrobiano, reduzindoa presença de bactérias e fungos nas amostras de caldo tratado. Aanálise em redes neurais artificiais (RNA) mostrou um bom ajuste na maioria dos casos apresentados e indicou que a variável Brix%caldo apresentou maior influência na redução da cor ICUMSA e o tempo a variável que apresentou a menor influência. / Clarification of the sugarcane juice is one of the most important steps within the entire sugar production process, so why is the color of the final sugar that determines its trading price in the market as well as its quality. However, besides having a color reduction process, which ultimately makes a quality sugar, it is necessary that this process does not generate waste or to the environment, and no toxic residues are present in the final product and that may harm consumer health. Thus, the search for alternative processes to sulfite - which is the current operating clarification of sugarcane juice in white crystal sugar production - has become more frequent. Such processes are known as advanced oxidation processes (AOP), and among them is the use of ozone. In this scenario evaluated the best conditions of pH, temperature and ozone dosing for reducing ICUMSA color of sugarcane juice, optimal conditions for obtaining such pH between 1.64 to 5.0, temperatures from 50 at 70 °C and ozone O3 dosages between 1.34 mg/min to 3.82 mg O3/min. The kinetic study of the reduction of ICUMSA color of sugarcane juice ozonized allowed to observe greater reductions ICUMSA color after 60 min of reaction, however the exposure of the juice long periods at low pH (1.64 and 3.0) associated with high temperatures (50 to 70 °C) led to hydrolysis of sucrose to glucose and fructose, which would make the process. Analysis by mass spectrometry allowed to observe that the reduction in ICUMSA color content of sugarcane ozonated juice samples not associated with the elimination of promoting particles color, but the precipitation of these particles, since they were not novel compounds identified in the samples, but a variation in concentration of these compounds, identified as lipids. In addition to further reduce the ICUMSA color of juice, ozone is also presented as an antimicrobial agent, reducing the presence of bacteria and fungi on the treated juice samples. The analysis on artificial neural networks (ANN) showed good fit in most cases presented and indicated that the variable Brix%juice showed greater influence in reducing ICUMSA color and time the variable that had the least influence.
598

Produção eletroquímica de ozônio: investigação de aspectos fundamentais e práticos / Electrochemical ozone production: investigation of fundamental and practical aspects

Santana, Mário Henrique Palis 14 April 2005 (has links)
A caracterização ex situ e in situ de eletrodos constituídos de IrO2-Nb2O5 revelou que a morfologia, a atividade eletrocatalítica para a reação de desprendimento de O2 (RDO) e a performance para a reação de formação de O3 (RFO) são fortemente dependentes da composição nominal da camada ativa. Baseados em estudos preliminares, escolheu-se a composição IrO2-Nb2O5 (45:55 % mol) para uma extensiva investigação da RDO/RFO, avaliando a influência das variáveis de preparo do eletrodo, da temperatura e da composição do eletrólito. Propôs-se um mecanismo eletródico para RDO/RFO, considerando a influência da composição do eletrólito e dos sítios ativos superficiais. Demonstrou-se que a introdução de PF6- no eletrólito de suporte aumenta significativamente o rendimento da RFO através da inibição da RDO no domínio dos elevados sobrepotenciais. O segundo material eletródico investigado foi o eletrodo de diamante dopado com boro (DDB) de origem comercial. Este material apresenta área superficial e rugosidade sensivelmente maiores que os reportados na literatura, sendo que as diversas análises demonstram um filme de boa qualidade. O pré-tratamento da superfície de DDB resulta na remoção de impurezas e na oxidação da superfície, alterando o caráter hidrofóbico do eletrodo. Sua condutividade e comportamento eletroquímico são dependentes da concentração superficial de transportadores de carga, relacionado diretamente ao potencial aplicado. Desta forma, este eletrodo de DDB altamente dopado apresenta comportamento próximo ao de um metal em potenciais mais anódicos. Os estudos cinéticos em diversos eletrólitos e temperaturas demonstram que o eletrodo de DDB caracteriza-se pela quase ausência de sítios de adsorção ? causa dos elevados sobrepotenciais e energias de ativação para a RDO. De forma surpreendente, a introdução de flúor-ânions no eletrólito resulta na diminuição da energia de ativação para a RDO e da eficiência de corrente para a RFO. Este último parâmetro é função direta da ?eletronegatividade absoluta? dos flúor-ânions. Altas concentrações de NaF alteram a condutividade do eletrólito e a hidrofobicidade do eletrodo, afetando o comportamento cinético do ânodo. Em eletrólitos contendo KPF6, entretanto, a entropia de ativação eletroquímica parece exercer um pronunciado efeito sobre a energia de ativação da RDO. No mecanismo proposto para o eletrodo de DDB, destaca-se a importância da interação entre o principal intermediário da RDO/RFO, HO·, e a superfície do filme. / Ex situ and in situ characterisation of IrO2-Nb2O5 electrodes reveal morphology, electrocatalytical activity for the oxygen evolution reaction (OER) and electrochemical ozone production (EOP) performance are strongly dependent on nominal composition of the oxide film. Based on preliminary studies, the electrode IrO2-Nb2O5 (45:55 mol%) composition was chosen to conduct an extensive OER/EOP investigation, analysing the influence of: electrode preparation procedure, temperature and electrolyte composition. An electrode mechanism for OER/EOP is proposed taking into account the influence of the electrolyte composition and the active surface sites. It is demonstrated that the introduction of PF6- into the electrolyte increases significantly the EOP performance due to inhibition of the OER in the high overpotential domain. The second electrode material investigated is a commercial sample of the boron doped diamond electrode (BDD). This material presents surface area and roughness considerably higher than those reported in literature, however several analyses demonstrate the good quality of the film. The pre-treatment of the BDD surface results in the removal of impurities and surface oxidation, which alters the hydrophobic character of the film. Its conductivity and electrochemical behaviour depend on the surface charge carriers concentration that is directly related to the applied potential. Therefore, this heavily doped BDD sample presents a behaviour resembling a metal at more anodic potentials. Kinetic investigations of several electrolytes and temperatures show BDD electrode is characterised by the almost absence of adsorption sites ? the main cause of the high overpotentials and activation energies for OER. Surprisingly, the introduction of fluoro-anions into the electrolyte results in lower activation energies for OER and lower EOP current efficiency. The latter parameter is directly related to the ?absolute electronegativity? of the fluoro-anions. High NaF concentrations modify the electrolyte conductivity and electrode hydrophobicity. However, in electrolytes containing PF6-, the electrochemical activation entropy seems to exert a pronounced effect on the activation energy for OER. In the proposed OER/EOP mechanism at BDD electrode, a key parameter is the interaction between the main intermediate, HO·, and the electrode surface.
599

Degradação de poluentes emergentes por processos oxidativos avançados (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) visando o tratamento de efluentes hospitalares / Degradation of emergent pollutants by advanced oxidative processes (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) aiming at hospital wastewater treatment

Souza, Fernanda Siqueira January 2016 (has links)
Compostos farmacêuticos são detectados em diversas matrizes ambientais. Estes compostos, quando não eliminados por técnicas avançadas de tratamento, contribuem para impactos ambientais negativos. Especificamente, efluentes hospitalares apresentam altas concentrações destes compostos principalmente pela excreção por pacientes. Neste contexto, o presente trabalho visa contribuir com a pesquisa científica em relação a efluentes hospitalares no Brasil, propondo alternativas de tratamento com ozônio para a remoção de fármacos. Para atingir o objetivo proposto, foi realizado um diagnóstico em um hospital visando identificar o consumo das principais classes farmacêuticas. A partir deste estudo, desenvolveu-se um planejamento de experimentos para avaliar os parâmetros mais adequados do processo de ozonização para a remoção de cafeína (CAF), amoxicilina (AMX) e ampicilina (AMP) em soluções aquosas. Foram avaliados experimentalmente os processos O3, O3/UV, O3/Fe2+, O3/UV/Fe2+. Investigou-se a influência da concentração inicial de fármaco, do pH, da potência de luz UV aplicada e da concentração inicial de Fe2+ utilizado como catalisador homogêneo. A variável de resposta foi a eficiência de mineralização. Os parâmetros obtidos pelo planejamento experimental foram aplicados para o Atenolol (ATE) e para soluções aquosas contendo a mistura de todos os compostos analisados (CAF, AMX, AMP e ATE). Um estudo cinético para determinação das constantes de reação foi realizado para a cafeína e atenolol. Para avaliar o tratamento com efluente hospitalar, uma caracterização (detecção de compostos farmacêuticos e parâmetros físico-químicos e toxicológicos) foi realizada antes e após o processo que apresentou a melhor eficiência de mineralização. Com o objetivo de extrapolar os estudos realizados e avaliar outros poluentes emergentes, além dos compostos farmacêuticos, realizaram-se experimentos com 90 compostos como drogas de abuso, hormônios e produtos de higiene pessoal que também podem estar presentes em efluentes hospitalares, avaliando a influência do pH e da dosagem de ozônio aplicada. Como principais resultados, os antibióticos e cardiovasculares foram as classes farmacêuticas mais consumidas no hospital. Pelo planejamento de experimentos, observou-se que todos os compostos avaliados foram rapidamente degradados (100% em menos de 15min) e as melhores eficiências de mineralização atingiram 70,8%, 60,4% e 63,6% para CAF, AMX e AMP, respectivamente. O sistema O3/UV/Fe2+ obteve a melhor eficiência de mineralização para o ATE (67,9%) e para a mistura dos compostos (69,5%). O estudo cinético possibilitou o cálculo das constantes cinéticas: kO3 =697,46 M-1 s-1 e kOH = 6,41x109 M-1 s-1 para a cafeína; e kO3 =146,56 M-1 s-1 e kOH = 15,29x109 M-1 s-1 para o atenolol. A eficiência de mineralização para os experimentos com efluente hospitalar atingiu 54,7% para o sistema O3/UV, sendo eficiente para a completa eliminação de diversos compostos farmacêuticos e remoção da toxicidade. Em relação à remoção dos 90 poluentes emergentes, observou-se que 53,3% dos compostos foram completamente degradados utilizando uma razão mMO3/mMC=0,3 em pH neutro. Os resultados encontrados indicam que o presente trabalho contribui para o avanço da pesquisa sobre efluentes hospitalares, pois apresenta uma alternativa de tratamento eficiente para a completa remoção de diversos compostos farmacêuticos, minimizando o impacto negativo destes no meio ambiente. / Pharmaceutical compounds (PhCs) are detected in various environmental matrices. These compounds, whether not eliminated by advanced treatment techniques, contribute to bacterial resistance and negative environmental impacts on water resource. Specifically, hospital wastewaster exhibit high concentrations of these compounds mainly by the excretion by patients. In this context, this paper aims to contribute to scientific research regarding hospital wastewater in Brazil, proposing treatment alternatives by ozone to remove PhCs. To achieve this purpose, it conducted a diagnosis in a hospital to identify the consumption of major pharmaceutical classes. With this result, it developed an experimental design to evaluate the most appropriate parameters of the ozonation process for the removal of caffeine (CAF), amoxicillin (AMX) and ampicillin (AMP) in aqueous solutions. This study evaluated the following processes experimentally: O3, O3/UV, O3/Fe2+ O3/UV/Fe2+. The influence of ozone dose, initial PhCs concentration, pH, power UV light applied and Fe2+ initial concentration used as homogeneous catalyst were investigated. Mineralization efficiency was the response variable. Parameters obtained by the experimental design were applied for Atenolol (ATE) and aqueous solutions containing the mixture of all compounds analyzed (CAF, AMX, AMP and ATE). A kinetic study for the determination of reaction constants was carried out for caffeine and atenolol. To evaluate the hospital wastewater treatment, a characterization (detection of pharmaceutical compounds and physico-chemical and toxicological parameters) was performed before and after the process that showed the best mineralization efficiency. In order to extrapolate the studies and evaluate other emergent pollutants, in addition to pharmaceutical compounds, were conducted experiments with 90 compounds such as illicit drugs, hormones and personal care products, which also may be present in hospital wastewater, evaluating the influence of pH and ozone dosage. Main results showed that antibiotics and cardiovascular were the most consumed pharmaceutical classes in the hospital. For the design of experiments, it was observed that all the evaluated compounds were rapidly degraded (100% in less than 15 minutes) and the best mineralization efficiency reached 70.8%, 60.4% and 63.6% for CAF and AMX AMP, respectively. The system O3/UV/Fe2+ obtained the best mineralization efficiency for ATE (67.9%) and mixture of compounds (69.5%). The kinetic study allowed the determination of the kinetic constants: kO3 = 697.46 M-1 s-1 and kOH = 6.41x109 M-1 s-1 for caffeine; and kO3 = 146.56 M-1 s-1 and kOH = 15.29x109 M-1 s-1 for atenolol. Mineralization efficiency for hospital wastewater experiments reached 54.7% by the system O3/UV, being efficient for complete elimination of various PhCs and removal of toxicity. Regarding the removal of 90 emergent pollutants, it was observed that 53.3% of the compounds were completely degraded using a ratio mMO3/MMC = 0.3 at neutral pH. The results indicated that this work contributes to the advance of research on hospital wastewater, because it presents an effective alternative treatment for complete removal of various pharmaceutical compounds, minimizing the negative impact on the environment.
600

Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection process

Souza, Jeanette Beber de 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested

Page generated in 0.0897 seconds