• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Pedro Yoshito Noritomi / Banca: Paulo Sérgio Perri de Carvalho / Banca: Fellippo Ramos Verri / Banca: Marcelo Ferraz Mesquita / Banca: Pedro Tortamano Neto / Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below) / Doutor
452

Avaliação biomecânica de próteses unitárias sobre implantes de hexágono interno em maxila anterior com diferentes tipos de ancoragem óssea e comprimentos de implantes. Estudo pelo método dos elementos finitos 3-D. /

Cruz, Ronaldo Silva. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Eduardo Piza Pellizzer / Banca: Joel Ferreira Santiago Junior / Resumo: Proposição: A proposta dessa pesquisa foi avaliar a distribuição de tensões em próteses unitárias implantossuportadas de hexágono interno (HI) na região maxilar anterior, variando a técnica de ancoragem óssea (Convencional (C), Bicorticalização (B) e Bicorticalização com elevação do assoalho nasal (BEAN) e as direções de carregamento (0°, 30° e 60°) por análise tridimensional (3D) de elementos finitos. Material e métodos: Três modelos tridimensionais foram simulados com ajuda dos programas Invesalius, Rhinoceros 3D 4.0 e SolidWorks 2011. Cada modelo possuía um bloco ósseo da região anterior do maxilar (osso tipo III) com 10m de altura padrão com um implante (4×8,5 mm (C), 4x10mm (B) e 4x11,5mm (BEAN), suportando uma coroa cimentada metal free. Os modelos foram processados pelos programas FEMAP v.11.0 e NEiNastran 11, utilizando uma força de 178 N em diferentes inclinações (0°, 30°, 60°). Os resultados foram plotados em mapas de tensão de von Mises (TvM), tensão máxima principal (TMxP), Microstrain (με) e Tendência de deslocamento (TD). Resultados: Análise de TvM mostrou aumento da concentração de tensão com o aumento da inclinação da força para os implantes, parafusos de fixação e abutments, com padrão similar de distribuição para os modelos testados. Sob análise de TMxP e με, o tecido ósseo apresentou maiores concentrações de tensões de tração sob cargas oblíquas (30° e 60°) ao redor do pescoço do implante na técnica convencional. Análise de deslocamento mostrou aumento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CRUZ, R. S. Biomechanical evaluation of unitary prostheses on implants of internal hexagon in anterior maxilla with different types of bone anchorage and implant lengths. Study by the finite element method 3- D. 2017. Dissertation (Masters in Dental Science, Biomaterials concentration area) - Faculty of Dentistry of Araçatuba, Paulista State University, Araçatuba 2017. Proposition: The purpose of this research was to evaluate the stress distribution of single crowns supported by internal hexagon (HI) implants in the anterior region of the maxilla, varying the bone anchoring technique (conventional (C), bicorticalization (B) and bicorticalization with nasal floor elevation (BNFE) at loading directions (0°, 30° and 60°) by three-dimensional (3D) finite elemento analysis. Material and methods: Three 3D models were designed with aid of Invesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software. Each model contained a bone block of the premaxillary área (type III bone) with 10m of standard height with one implant (4×8, 5mm (C), 4x10mm (B) and 4x11.5mm (BNFE)), supporting a cemented metal free crown. The models were processed by the FEMAP v.11.0 and NEiNastran 11 using load of 178 N at different inclinations (0°, 30°, 60°). Von Mises (TvM), maximum principal stress (TMxP), microstrain (με) and displacement maps (D) were plotted to results analysis. Results: Analysis of TvM showed increased of stress concentration with increasing load inclination for implants, fixation screws and abtments, with similar pattern of distribution for the tested models. Under TMxP and με analysis, bone tissue showed higher traction stress concentrations under oblique loads (30 ° and 60 °) around the implant neck for the conventional technique. Displacement analysis showed increase of inclination tendency similar for all models ... (Complete abstract electronic access below) / Mestre
453

Influência do processamento de próteses totais maxilares com diferentes espessuras da base : análise gráfica da movimentação dos dentes artificiais /

Mazaro, José Vitor Quinelli. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Milton Carlos Gonçalves Salvador / Banca: Humberto Gennari Filho / Banca: Eduardo Piza Pellizzer / Resumo: A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA – á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below). / Mestre
454

Influência da geometria oclusal e material restaurador na carga para fratura e distribuição de tensões em coroas totais /

Lima, Aline Lins de. January 2014 (has links)
Orientador: Alexandre Luiz Souto Borges / Banca: Gilberto Antonio Borges / Banca: Tarcísio José de Arruda Paes Júnior / Resumo: Este estudo avaliou a influência de diferentes padrões de altura de cúspides de restaurações totais fornecidos pelo banco de dados do sistema CAD/CAM CEREC (Jovem, Asiático e Adulto) na carga para fratura de dois materiais restauradores (resina acrílica e cerâmica). Sessenta preparos para coroa total em G10 (tecido de fibra de vidro impregnado com resina epóxi substituto personalizado da dentina) foram digitalizados pelo. CEREC e divididos em três grupos segundo os padrões oclusais fornecidos pelo banco de dados do CEREC de acordo com as diferentes alturas de cúspide: Jovem (J), Asiático (As) e Adulto (Ad). Cada padrão oclusal foi usinado com dois tipos de materiais diferentes: um com baixo módulo elástico (6 ± 0.5GPa) resina acrílica CAD-Waxx(R) e outro com alto módulo elástico (63 ± 0.5GPa) cerâmica feldspática VITA Mark II(C). Os preparos em G10 foram incluídos em resina de poliuretano e foram simulados alvéolos artificiais com poliéter de consistência leve. Todas as coroas foram cimentadas com cimento resinoso dual RelyX ARC® e armazenadas em água destilada por 24 h. Os corpos-de-prova foram submetidos ao teste de carga para fratura utilizando uma máquina de ensaios universal (EMIC - DL1000MF) com célula de carga de 1000 kgf a uma velocidade de 1.0 mm/min. Diferentes tipos de fratura foram obtidos e então classificados em cinco padrões: 1 (envolvendo o sulco central), 2 (envolvendo cúspides disto-lingual e disto-vestibular), 3 (envolvendo a cúspide disto-lingual), 4 (envolvendo sulco central e sulco lingual) e 5 (fratura em diversas partes). As médias e valores de carga para fratura, dados em Newton (N), foram analisados estatisticamente por meio dos testes ANOVA e Tukey (5%). O teste ANOVA dois fatores mostrou diferença estatisticamente significante para os fatores testados e o efeito interação (p < 0.05). As médias, desvios-padrões e resultados do teste de Tukey foram os seguintes: R/J- 2007.0 N ±... / Abstract: This study assessed the influence of different cuspal patterns of total restorations provided by the database CEREC CAD/CAM system (Young, Asian and Adult shape) on load-to-fracture of two restorative materials (resin or ceramic). Sixty anatomic total crown preparations in G10 (customized Dentin Substitute) were scanned with CEREC and divided in three groups according to the occlusal pattern from CEREC database with different cusp heights: Young (Y), Asian (As) and Adult (Ad). Each occlusal pattern was machined with two different types of materials: one with a low-elastic modulus (6 ± 0.5GPa) CAD-Waxx resin (R) and another with a high-elastic modulus (63 ± 0.5GPa) VITA Mark II ceramic (C). The G10 specimens were embedded in polyurethane and artificial alveoli were simulated using a polyether. All crowns were cemented with resinous dualcure cement and stored in distilled water for 24 h. The specimens were load to fracture using a universal testing machine (EMIC- DL1000MF) with a load-cell of 1000 kgf at a crosshead speed of 1.0 mm/min. The fracture type was classified in five patterns: 1 (involving the central sulcus), 2 (involving distal-lingual and distal-buccal cusps), 3 (involving the lingual cusp), 4 (involving the central and lingual sulcus), and 5 (crown fractured in several parts). Load fracture means were analyzed with ANOVA and tukey's tests(5%). ANOVA two-way showed significant differences for the tested factors and for their interaction (p < 0.05). The means ± SD and results of tukey's test were: R/Y- 2007.0 ± 345.0a, R/As 742.6 ± 142.0b, R/Ad 1139.0 ± 132.0c, C/Y- 454.2 ± 77.5d, C/As 590.9 ± 94.3b, C/Ad 1149,4 ± 201.0c (different letters mean significant differences). The Adult pattern showed predominantly type 1 fractures for CAD-Waxx and type 5 for VITA Mark II. For the Asian pattern, type 3 was predominant for both materials. For the Young pattern, similar percentage for type 1 and 2 for CAD-Waxx, While for VITA..... / Mestre
455

Influência da carga oclusal parafuncional em próteses implantossuportadas, variando-se a proporção coroa/implante e o sistema de conexão protética : estudo pelo método dos elementos finitos tridimensionais /

Torcato, Leonardo Bueno. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Ferraz Mesquita / Banca: Fellippo Ramos Verri / Resumo: A condição de carga tem sido considerada o fator mais importante para a manutenção em longo-prazo da osseointegração e sucesso do tratamento reabilitador, portanto, é essencial otimizar a distribuição da carga mastigatória no complexo implante-coroa-parafuso. A proposta do presente estudo foi analisar, através do método dos elementos finitos tridimensionais, a influência do carregamento oclusal parafuncional, da proporção coroa/implante e da conexão protética (hexágono externo, hexágono interno e cone-morse) na distribuição das tensões em próteses unitárias implantossuportadas. Foram confeccionados cinco modelos tridimensionais com o auxílio de um scanner 3D MDX-20 e dos programas de modelagem gráfica: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks 2010 (SolidWorks Corp, Massachusetts, USA). Cada modelo foi composto por um bloco ósseo proveniente da região molar mandibular, por um implante dentário (Conexão Sistema de Prótese Ltda, São Paulo, Brasil) e por coroa metalocerâmica com diferentes alturas: 10, 12.5 e 15 mm. Os modelos tridimensionais foram exportados para o programa de elementos finitos FEMAP 10.1 (Noran Engineering, Inc., EUA), para estabelecimento das condições de contorno e geração da malha de elementos finitos. Aplicou-se uma carga funcional (200 N axial e 100 N oblíqua), bem como uma carga parafuncional (1000 N axial e 500 N oblíqua). A carga axial foi dividida em 4 pontos, localizados nas vertentes internas das cúspides, enquanto que a carga oblíqua foi dividida em 2 pontos, os quais localizaram-se nas vertentes internas das cúspides linguais. Os resultados foram visualizados por meio dos mapas de Tensão de von Mises e mapas de Tensão Máxima Principal. O carregamento parafuncional e o aumento da proporção coroa/implante induziram um aumento da área de distribuição e da magnitude das tensões no ... / Abstract: The load condition has been considered the most important factor for the long-term osseointegration maintenance and for the rehabilitation treatment success, then, it is essential to optimize the masticatory loading distribution on the implant-crown-screw complex. The purpose of this study was to analyze, through the 3D finite element method, the influence of parafunctional occlusal loading, the crown/implant ratio and the prosthetic connection (external hexagon, internal hexagon and morsetaper) on stress distribution in implant-supported single prostheses. Five 3D models were created with the aid of a 3D scanner MDX-20 and the graphical modeling softwares: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks 2010 (SolidWorks Corp., Massachusetts , USA). Each model was composed of a bone block from the mandibular molar region, a dental implant (Conexão Sistema de Prótese Ltda, São Paulo, Brazil) and a metal-ceramic crown with different heights: 10, 12.5 and 15 mm. The 3D models were exported to the finite element software FEMAP 10.1 (Noran Engineering, Inc., USA) to have the boundary conditions established and the finite element meshes generated. A functional load (200 N axial and 100 N oblique) and a parafunctional load (1000 N axial and 500 N oblique) were applied on the occlusal surface of the crowns. The axial load was divided in four points located in the internal slope of the cusps, while the oblique load was divided into two spots, which were located in the internal slopes of the lingual cusps. The results were visualized through von Mises Stress and Maximum Principal Stress maps. The parafunctional load and the increased crown/implant ratio caused an increase in the distribution area and of the magnitude of the stresses in the implant (hexagon region, platform and first thread) and screw (neck). The conical internal connection ... / Mestre
456

Avaliação da precisão e distribuição de tensões em próteses fixas sobre implantes de hexágono externo obtidas por diferentes sistemas CAD-CAM /

Mello, Caroline Cantieri de. January 2017 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Fellippo Ramos Verri / Banca: José Vitor Quinelli Mazaro / Banca: Ricardo Alexandre Zavanelli / Banca: Joel Ferreira Santiago Junior / Resumo: Os sistemas CAD-CAM tem sido responsáveis por automatizar a produção odontológica, otimizando o tempo e tornando este processo cada vez mais viável. Objetivo: O objetivo deste trabalho foi mensurar as desadaptações marginais vertical (DMV) e horizontal positiva (DMHP) e negativa (DMHN) de PPF de zircônia confeccionadas por diferentes sistemas CAD-CAM e por um método convencional, e analisar pelo MEF-3D (método dos elementos finitos tridimensionais) a influência das desadaptações no comportamento biomecânico das estruturas protéticas. Além disso, confeccionar uma revisão sistemática e meta-análise comparando os estudos da literatura que tenham avaliado a desadaptação marginal de próteses e componentes protéticos implantossuportados confeccionados pelos sistemas CAD-CAM e pelo método convencional da fundição por cera perdida. Materiais e Métodos: Quarenta infraestruturas (n=10) foram confeccionadas (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni-Cr), e randomizadas para mensuração das desadaptações. Os resultados encontrados foram submetidos à análise de variância (ANOVA), com nível de significância à 5%. Os valores médios de DMV de cada grupo foram utilizados para a confecção de 6 modelos pelo MEF-3D, submetidos à aplicação de forças axiais e oblíquas. Os resultados foram visualizados através de mapas de tensão Von Mises. A revisão sistemática foi desenvolvida de acordo com o PRISMA e registrada na plataforma PROSPERO (CRD42017055685). Resultados: Os resultados ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CAD - CAM systems in dentistry automate production, thus optimizing time and making the process even more convenient. Purpose : The aim of this study was to measure vertical (VMD) and positive (PHMD) and negative horizontal ( N HMD) marginal discrepancy of FPD frameworks made by different CAD - CAM systems (zirconia Y - TZP) and conventional method (cast), and to analyze by FEA - 3D the biomechanical performance of implant - prosthesis misfit. In addition, to do a systematic review and m eta - analysis comparing studies in the literature that have evaluated the marginal misfit of prostheses and implant - supported prosthetic components made by the CAD - CAM systems and the conventional method of lost - wax casting. Material and Methods: Forty fram eworks (n=10) were fabricated (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni - Cr ) and were randomized, to measure the misfits. The results were submitted to analysis of variance (ANOVA), with significance level at 5%. The average values of DMV of each g roup were used to make six models using FEA - 3D, applying axial and oblique loads. The results were analyzed using maps of Von Mises stresses, for each model. The systematic review was developed according to PRISMA statement and was register in the PROSPERO (International prospective register of systematic reviews) ( CRD42017055685). Results: The results of chapter 1 were: the conventional method showing the lowest values of vertical misfit compared to CAD - CAM systems (p<0.05). The CAD - CAM systems showing low est values of PHMD (p=0.014) and the conventional method did not present values of NHMD. In the biomechanical analysis, the oblique loading concentrated a greater amount of stresse s than the axial loading, in all situations evaluated. The fit models presen ted the most favorable biomechanical performance compared...(Complete abstract electronic access below) / Doutor
457

Efeito da altura da união implante/componente protético sobre os tecidos periimplantares: estudo clínico e radiográfico em cães

Paula, Wagner Nunes de [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-28Bitstream added on 2014-06-13T20:36:52Z : No. of bitstreams: 1 paula_wn_me_arafo.pdf: 549135 bytes, checksum: 1cd91d5b53b64bec46b8e5ace0efab34 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC.
458

Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato

Lemo, Vagner Samy [UNESP] 27 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-27Bitstream added on 2014-06-13T19:15:55Z : No. of bitstreams: 1 lemo_vs_me_arafo.pdf: 419894 bytes, checksum: cba02ae2b99c2cf288790005f4e2b328 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants.
459

Caracterização do nanocompósito de Al2O3 com inclusões nanométricas de ZrO2 visando sua aplicação como reforço em próteses odontológicas de cerâmica livre de metal / Characterization of al2o3 with nanometric zro2 inclusions nanocomposite reinforcing metal-free dental prosthesis

Pierri, Juliano de 22 February 2008 (has links)
Made available in DSpace on 2016-06-02T19:12:07Z (GMT). No. of bitstreams: 1 3329.pdf: 6374994 bytes, checksum: a47986d4181e05b6e83318ff5e2d9a33 (MD5) Previous issue date: 2008-02-22 / Financiadora de Estudos e Projetos / There are many different materials used in dental prosthesis, metal combined with ceramic (metalloceramic), combination of polymers with metal (metal-polymer), metal, polymer and ceramic metal free or metal-free. Metalfree dental prostheses, including crowns and bridges, are attractive to dentists and patients because they have better aesthetics, abrasion resistance, biocompatibility and low thermal conductivity when compared with traditional metal-ceramic prostheses. However, mechanical failures may occur because they are fragile materials. Zirconia (ZrO2) and alumina (Al2O3) are ceramics that have mechanical and aesthetic features suitable for manufacture of these prostheses. In the late 80's, were obtained significant improvements in mechanical properties of composites consisting of alumina matrix with nanoscale inclusions. Previous experimental results showed that the addition of small amounts of nanometric zirconia to the alumina sets a material with interesting mechanical properties. This study proposes the use of composites with nanoscale inclusions of zirconia as a material for the preparation of metalfree dental prostheses. To check this possibility, alumina matrix nanocomposites samples were prepared with 5% of nanometric inclusions of ZrO2 to test the biocompatibility in vivo and some mechanichal properties. In the mechanical characterization tests were performed under 3 point bending (according to ISO 6872/97) and diametral tensile test. Biocompatibility tests were performed on bone and subconjunctival tissue of rats. The results showed that, in accordance with the standards in dentistry and compared with values observed in previous studies, the material in this study has excellent mechanical properties and excellent biocompatibility which allows its use as reinforcement in metal-free dental prostheses. / Existem inúmeros diferentes materiais usados em próteses odontológicas: metal combinado com cerâmica (chamadas metalocerâmicas), combinação de metal com polímeros (metaloplásticas), metálicas, poliméricas (com ou sem carga) e cerâmicas também chamadas metal free ou livres de metal. As próteses odontológicas livres de metal, incluindo coroas e pontes, são atrativas aos dentistas e pacientes pois possuem melhor estética, resistência a abrasão, biocompatibilidade e baixa condutibilidade térmica quando comparadas com as tradicionais próteses metalo-cerâmicas. No entanto, falhas mecânicas podem ocorrer nestes materiais pois são materiais frágeis. As cerâmicas que apresentam caracterísitcas estéticas e mecânicas adequadas para a confecção destas próteses são a zircônia (ZrO2) e a alumina (Al2O3). No final da década de 80, foram obtidas melhoras significativas nas propriedades mecânicas de compósitos formados por matriz de alumina com inclusões nanométricas. Resultados experimentais prévios, demonstraram que adições de pequenas quantidades de zircônia nanométrica à alumina permite obter um material com propriedades mecânicas adequadas. O presente estudo propõe a utilização de compósitos com inclusões nanométricas de zircônia como material para a preparação de próteses odontológicas livres de metal.Tendo como objetivo verificar tal possibilidade, foram preparadas amostras de nanocompósitos de matriz de alumina com 5% de inclusões nanométricas de ZrO2 para a realização de ensaios de resistência mecânica e de biocompatibilidade in vivo . Na caracterização mecânica foram realizados ensaios de flexão em 3 pontos (de acordo com a norma ISO 6872/97) e ensaio de tração diametral. Já os ensaios de biocompatibilidade foram realizados em tecido ósseo e subconjuntivo de ratos. Os resultados mostraram que, de acordo com as normas vigentes em odontologia e comparativamente com valores observados em trabalhos anteriores, o material em estudo apresenta excelentes propriedades mecânicas e excelente biocompatibilidade o que possibilita seu uso como reforço de próteses livres de metal.
460

Síntese, caracterização e estudo de nanômeros de silício como reforço mecânico em resinas acrílicas a base de PMMA / Synthesis, characterization and study of silicon nanomers as mechanical reinforcement in PMMA-based acrylic resins.

Lourenço, Rodrigo Vinicius 17 July 2014 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-09-26T13:03:07Z No. of bitstreams: 1 DissRVL.pdf: 3912816 bytes, checksum: d714dc4e7f214649710dbc2cad7d9f31 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-27T19:34:22Z (GMT) No. of bitstreams: 1 DissRVL.pdf: 3912816 bytes, checksum: d714dc4e7f214649710dbc2cad7d9f31 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-27T19:34:28Z (GMT) No. of bitstreams: 1 DissRVL.pdf: 3912816 bytes, checksum: d714dc4e7f214649710dbc2cad7d9f31 (MD5) / Made available in DSpace on 2016-09-27T19:34:35Z (GMT). No. of bitstreams: 1 DissRVL.pdf: 3912816 bytes, checksum: d714dc4e7f214649710dbc2cad7d9f31 (MD5) Previous issue date: 2014-07-17 / Não recebi financiamento / The search for improvements in material properties has been studied extensively and fabrication of polymeric nanocomposites stands out for having excellent mechanical properties. In this work, silicon nanomers were prepared by solgel process and grafted in a poly(methyl methacrylate) (PMMA) matrix by powderliquid polymerization, a very common process in prosthodontic procedures to polymerize acrylic resins. Two different types of nanomers were prepared: nanoparticles of silicon dioxide (NPs SiO2) from the tetraethylorthosilicate (TEOS) as precursor and molecules of polyhedral oligomeric silsesquioxane (POSS) from the methyl trimethoxysilane (MTMS), both using the silane coupling agent 3-(trimetoxisilil) propyl methacrylate (TMSPM) also as precursor. The nanomers were produced at different concentrations and embedded in the polymeric matrix after 1 and 7 days to form the PMMA/SiO2 and PMMA/POSS nancomposites. They showed different mechanical behavior with respect to present concentration in the matrix, for PMMA/SiO2 nanocomposites best results were obtained for flexural strength, flexural modulus, yield strength and surface microhardness at low concentrations (less than 1%), while PMMA/POSS with about 1,5% presented better results for flexural strength, flexural modulus and microhardness. In addition, there was a decline to almost all the observed results for the nanocomposites prepared after 7 days compared to those prepared after 1 day, regardless of nanomer and concentration. / A busca por melhorias nas propriedades dos materiais tem sido estudada extensivamente e a fabricação de nanocompósitos poliméricos ganha destaque por apresentarem excelentes propriedades mecânicas. Neste trabalho nanômeros de Silício foram preparados via sol-gel utilizando o monômero de metil metacrilato como meio homogeneizante e inseridos em matriz de poli(metilmetacrilato) (PMMA) por polimerização pó-líquido, processo muito comum na área odontológica para polimerização de resinas acrílicas. Dois tipos diferentes de nanômeros foram preparados: nanoparticulas de dióxido de silício (NPs SiO2) a partir do precursor: tetraetilortosilicato (TEOS) e moléculas de poliedros oligoméricos de silsesquioxanos (POSS) a partir do precursor metil trimetoxisilano (MTMS), ambos utilizando o agente de acoplamento silano 3-(trimetoxisilil) propil metacrilato (TMSPM) também como precursor. Os nanômeros foram produzidos em diferentes concentrações e inseridos na matriz polimérica após 1 e 7 dias para formarem os nanocompósitos PMMA/SiO2 e PMMA/POSS. Os nancompósitos apresentaram diferentes comportamentos mecânicos com relação a concentração presente na matriz. Para os nanocompósitos PMMA/SiO2, melhores resultados foram obtidos para resistência a flexão, módulo de flexão, tensão de escoamento e microdureza superficial em baixa concentração (abaixo de 1%), enquanto que PMMA/POSS, com aproximadamente 1,5%, apresentaram melhores resultados para resistência à flexão, módulo de flexão, e microdureza superficial. Além disso, houve decaimento para quase todos os resultados observados para os nanocompósitos preparados após 7 dias em comparação aos preparados após 1 dia, independente do nanômero e da concentração presente.

Page generated in 0.0379 seconds