• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • Tagged with
  • 69
  • 69
  • 33
  • 28
  • 26
  • 21
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • 10
  • 10
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo da configura??o de po?os no processo de drenagem gravitacional assistida por vapor (SAGD) em reservat?rios do nordeste brasileiro

Fernandes, Glydianne Mara Di?genes 02 September 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-02-10T16:44:40Z No. of bitstreams: 1 GlydianneMaraDiogenesFernandes_TESE.pdf: 3862064 bytes, checksum: fefa5eff9a9888901a0fc8b23ab2f361 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-02-10T21:36:27Z (GMT) No. of bitstreams: 1 GlydianneMaraDiogenesFernandes_TESE.pdf: 3862064 bytes, checksum: fefa5eff9a9888901a0fc8b23ab2f361 (MD5) / Made available in DSpace on 2017-02-10T21:36:27Z (GMT). No. of bitstreams: 1 GlydianneMaraDiogenesFernandes_TESE.pdf: 3862064 bytes, checksum: fefa5eff9a9888901a0fc8b23ab2f361 (MD5) Previous issue date: 2016-09-02 / As novas tecnologias que utilizam a recupera??o avan?ada de petr?leo surgiram da necessidade de se retirar o ?leo que ainda permanece no reservat?rio ap?s a recupera??o prim?ria. O objetivo desses m?todos ? elevar o fator de recupera??o do ?leo. Dessa forma, alguns projetos passam a se tornar vi?veis economicamente quando se utilizam esses m?todos. Os m?todos t?rmicos, dentre eles a inje??o de vapor, promovem a recupera??o do ?leo atrav?s da inser??o de energia t?rmica dentro do reservat?rio. O aumento da temperatura faz com que o ?leo tenha a sua viscosidade reduzida, aumentando assim, seu deslocamento em dire??o aos po?os de produ??o. O processo de drenagem gravitacional assistida por vapor (SAGD) ? um m?todo avan?ado de recupera??o. Sua configura??o apresenta dois po?os horizontais paralelos, um acima do outro. O vapor ? injetado de forma cont?nua ao longo do po?o injetor, em seguida forma-se uma c?mara de vapor que cresce at? encontrar os limites do reservat?rio. Este ?leo tem, ent?o, sua viscosidade reduzida e, pela a??o das for?as gravitacionais, ? drenado em dire??o ao po?o produtor. Neste contexto, esta pesquisa teve como objetivo realizar um estudo de diferentes configura??es de po?os injetores no processo SAGD, considerando os efeitos das perdas de carga e calor no po?o injetor em reservat?rios do nordeste brasileiro. Um planejamento fatorial foi utilizado para verificar a influ?ncia dos par?metros estudados no fator de recupera??o. Foi realizada tamb?m uma an?lise t?cnico econ?mica das configura??es dos po?os injetores com a finalidade de analisar a rentabilidade dos projetos estudados. Para a realiza??o das simula??es num?ricas foi utilizado o simulador t?rmico STARS da CMG (Computer Modelling Group). Os resultados mostraram que os po?os injetores inclinados apresentaram uma menor produ??o em rela??o ? configura??o com po?os horizontais. A configura??o com po?os injetores deslocados em rela??o ao po?o produtor (W-SAGD), para vaz?es de inje??o a partir de 100 ton/dia, levou a forma??o de uma c?mara de vapor maior e mais eficiente. Foi observado tamb?m que a utiliza??o de po?os injetores verticais (V-SAGD), para maiores vaz?es de inje??o de vapor, apresentou uma produ??o acumulada de ?leo menor, por?m, similar ao SAGD com po?o injetor horizontal. Na an?lise econ?mica, o modelo SAGD apresentou os maiores VPLs. / New technologies that use the enhanced oil recovery emerged the need to remove the oil that remains in the reservoir after primary recovery. The goal of these methods is to increase the oil recovery factor. Thus, some projects start to become economically viable when using these methods. The thermal methods, including steam injection, promote the recovery of oil through the thermal energy within the insert reservoir. The increased temperature causes the oil to have its viscosity reduced, thereby increasing its speed towards the production wells. The steam assisted gravity drainage process (SAGD) is an advanced method of recovery. Its configuration has two parallel horizontal wells, one above the other. The steam is injected continuously during the injection well, and then forms a steam chamber which grows to find the limits of the reservoir. This oil is then reduced its viscosity and, by the action of gravitational forces, it is drained toward the producing well. In this context, this study aimed to carry out a study of different configurations of injection wells in SAGD process, considering the effects of load loss and heat in the injection well in the Brazilian northeast reservoirs. A factorial design was used to investigate the influence of the parameters studied in the recovery factor. It also performed an economic analysis of the technical settings of injection wells in order to analyze the profitability of the projects studied. To perform the numerical simulations we used the thermal simulator CMG STARS (Computer Modelling Group). The results showed that the inclined injection wells had a lower production compared to the configuration with horizontal wells. A setting producer injectors offset from the well (W-SAGD) for injection flowrates from 100 ton/day, led to the formation of a vapor chamber larger and more efficient. It was also observed that the use of vertical injection wells (VSAGD), for larger flowrates, showed a lower cumulative production of oil, however, similar to SAGD injector well horizontally. In the economic analysis, the SAGD model showed the highest NPVs.
62

Estudo da aplicação de conversores catalíticos platina/paládio como auxiliar no processo de controle das emissões gasosas automotivas / Study of application of catalytic converters platin/palladium with auxiliary in the control process of emission gas automotives

Keyll Carlos Ribeiro Martins 30 June 2003 (has links)
Este trabalho de pesquisa visa estudar o processo de formação das emissões gasosas num motor de combustão interna movido à álcool e analisar os fatores que contribuem para o controle dessas emissões em níveis estabelecidos pela legislação. Especial atenção foi dada à aplicação de conversores catalíticos platina/paládio como auxiliar no processo de controle das emissões gasosas automotivas. Foram realizados ensaios dinanométricos de um motor de combustão interna para analisar as emissões e o controle destas, em condições operacionais, em função da razão ar-combustível, ponto de ignição e rotação. O conversor catalítico contribuiu para redução de mais de 80% das emissões gasosas danosas à saúde, quando o motor operava em condições estequiométricas. Observou-se a necessidade de desenvolver o sistema de admissão e descarga do motor para receber o catalisador sem que este cause redução considerável à queda da eficiência volumétrica do motor. / This work of research aim analyzes process of formation of gas emissions in alcohol internal combustion engines and analyses factors that contribute to control those emissions in level established by legislation. Special attention was faced application of catalytic converters platin/palladium with auxiliary in the process of control emissions gas automotives. Assays dynamometric were realized of to analyses emission and control them, in conditions operation ales, in function of air-fuel ratio, point of ignition and rotation the catalytic converters contribute to reduction more of 80% of emissions gas that cause damage health, when observed that necessity of develop system of admission and exhaust of engines to receive catalysts out that provocate reduction considerable decrease of efficiency volumetric of engines.
63

Análises experimental, teórica e computacional do escoamento dos gases de exaustão no conversor catalítico platina/paládio instalado em um motor de combustão interna a etanol / Experimental, theoretical, and computational analysis of exhaust gases flow in catalytic converter platinum-palladium of internal combustion engine burning ethanol

Keyll Carlos Ribeiro Martins 29 June 2006 (has links)
O trabalho consiste em análises experimental, teórica e computacional do escoamento dos gases de exaustão através de um conversor catalítico platina-paládio, instalado num motor de combustão interna movido a etanol. Foram realizados ensaios dinanométricos no motor para análise das medidas experimentais no sistema de exaustão e para aquisição de valores das propriedades termodinâmicas, de transporte e de concentrações químicas, os quais serviram de dados iniciais para a simulação computacional desenvolvida com a utilização dos softwares CFX e MFIX. Os programas resolvem um conjunto de equações conservativas que permitem a análise da variação da pressão, temperatura, velocidade e composição química dos gases de escape ao longo do suporte monolítico. Além de avaliar a formação e os níveis das emissões provenientes da combustão da mistura ar-combustível. A eficiência catalítica no primeiro suporte do conversor foi de 11% THC, 100% NOx e 20% CO. Foi verificada uma diferença de 1,23% entre a velocidade média experimental e a simulada. Modelos matemáticos foram aplicados no estudo da perda de carga no conversor catalítico e na relação difusão-reação do consumo e formação das espécies químicas. / The thesis describes computational, experimental, and theoretical analysis of the exhaust gases flow through a Pt/Pd catalytic converter installed on internal combustion engine burning ethanol. The obtained values related to energy properties and mass transport in experimental tests is the base of initial values for development of the computational simulation by using CFX and MFIX software. The programs solves a group of conservative equations that allow to analysis of variation such as pressure, temperature, and also, velocity of exhausting gases along the monolithic support, moreover to evaluate the formation of gases and its emission levels on the incoming air-fuel mixture combustion and its respective chemical reactions of oxidation. The catalytic efficiency through the first monolith of the converter were about of 11% THC, 100% NOx e 20% CO. It was verified also a small difference of 1,2 % between the experimental and the simulated average velocity. In addition mathematical models were applied on the study of the load loss in catalytic converter, diffusion-reaction of the consumption and also formation of chemical species.
64

Um estudo experimental da ebulição convectiva de refrigerantes no interior de tubos lisos e internamente ranhurados / An experimental study of convective flow boiling of refrigerants inside smooth and microfin tubes

Enio Pedone Bandarra Filho 29 April 2002 (has links)
A presente pesquisa trata de um estudo experimental da transferência de calor e da perda de carga de fluidos refrigerantes puros e suas misturas em mudança de fase convectiva no interior de tubos lisos e aqueles dotados de ranhuras internas. Para tanto, foi desenvolvido um equipamento experimental cujo componente básico é composto por um tubo horizontal, aquecido por intermédio de uma resistência elétrica do tipo fita, aderida à superfície externa do tubo. As condições de ensaio variaram numa ampla faixa, permitindo cobrir as condições verificadas na maioria das instalações frigoríficas. Os resultados experimentais foram agrupados em duas faixas de velocidades mássicas: elevadas (G > ou = 200 kg/s.m2), onde prepondera o padrão anular de escoamento, e reduzidas (G < 200 kg/s.m2), predominando o padrão estratificado. Os principais parâmetros que afetam o coeficiente de transferência de calor, tais como, velocidade mássica, fluxo de calor, tipo de refrigerante, temperatura de evaporação e diâmetro do tubo foram analisados. O desempenho termo-hidráulico, relativo ao efeito combinado da transferência de calor e da perda de carga dos tubos ranhurados, foi sensivelmente superior quando comparados aos tubos lisos. A análise dos resultados experimentais permitiu a proposição de correlações para a perda da carga, avaliada através do multiplicador bifásico, &#966L, e para coeficiente de transferência de calor, em tubos lisos e ranhurados. As correlações propostas se mostraram adequadas para aplicações práticas, proporcionando desvios reduzidos em relação aos resultados experimentais. Destacam-se as correlações obtidas para o multiplicador bifásico para tubos microaletados e para o coeficiente de transferência de calor para vazões reduzidas em tubos lisos. Diversos registros fotográficos dos principais padrões de escoamento foram levantados, tendo sido importante na análise e entendimento da mudança de fase. / Present research deals with an experimental study of the heat transfer and pressure drop of pure and mixtures of refrigerants undergoing convective boiling inside horizontal smooth and microfin tubes. An experimental apparatus has been developed and constructed whose main component is a horizontal tube electrically heated. Experimental results have been grouped into two mass velocity ranges: the one corresponding to mass velocities lower than 200 kg/s.m2, where the stratified flow pattern is dominant, and that for mass velocities higher than 200 kg/s.m2, where typically the annular flow pattern can be found. Effects over the heat transfer coefficient of physical parameters such as mass velocity, heat flux, diameter, saturation temperature, and refrigerant have been investigated and analyzed. It has been found out that the thermo-hydraulic performance of microfin tubes is better than that of the smooth ones. Empirical correlations have been proposed for both the two-phase flow multiplier and the heat transfer coefficient for different ranges of operating conditions as well as for smooth and microfin tubes. Results from the proposed correlations can be deemed adequate for practical applications given the limited dispersion obtained with respect to their experimental counterpart. Noteworthy are the results obtained from correlations for both the two phase flow multiplier for microfin tubes and the heat transfer coefficient for the lower range of mass velocities in smooth tubes. Finally, worth mentioning is the photographic essay developed in present research involving the flow patterns that occur under convective boiling of refrigerants in horizontal tubes.
65

Estudo da condensação de refrigerantes halogenados e suas misturas com óleo de lubrificação no interior de micro canais / Condensation study of halogen refrigerants and mixtures with lubricant oil in microchannel tubes

Williams Gonzales Mamani 26 October 2001 (has links)
A presente pesquisa envolve um estudo teórico-experimental da transferência de calor e da perda de carga na condensação e no escoamento monofásico de fluidos refrigerantes halogenados no interior de lâminas com micro canais. Os ensaios consideram o fluido refrigerante puro R-134-a e a mistura quase azeotrópica R-410A. As lâminas estudadas envolvem micro canais de seção quadrada de Dh = 1,214 mm e de seção circular de Dh = 1,494 mm. Os ensaios de líquido subresfriado compreendem velocidades mássicas de 390 a 1360 Kg/sm2 para um temperatura de saturação de 40ºC e subresfriamento de 10ºC. Por sua parte, os ensaios foram realizados considerando um fluxo de calor constante de 5 kW/m2, títulos de vapor de 0,1 a 0,9, velocidades mássicas de 410 a 1135 kg/sm2, temperaturas de saturação de 40 a 50ºC e misturas óleo-refrigerante com concentrações de óleo em massa de 0,25 e 0,45%. Para cada condição de ensaio foram avaliados o coeficiente de transferência de calor e a queda de pressão por atrito na lâmina ensaiada. Os resultados para escoamento monofásico apresentaram consistência com relação às correlações típicas aplicáveis a transferência de calor e perda de carga para regime turbulento em tubos convencionais, apresentando, em média, valores de 12% superiores. Na maioria das condições de ensaios de condensação, segundo mapas de escoamento disponíveis na literatura, foi identificado o domínio do padrão estreitamento anular. Este comportamento foi aferido pelos resultados experimentais de perda de carga mostrando dependência quase exclusiva do parâmetro de Martinelli, e o mecanismo conectivo como principal mecanismo de transferência de calor, característico no padrão anular. Os resultados de condensação foram correlacionados a partir de abordagens empíricas em função do parâmetro de Martinelli e o conceito de velocidade mássica equivalente. Assim como, a partir de uma abordagem semi-empírica considerando um modelo anular que permite avaliar os mecanismos principais de transferência de calor e quantidade de movimento, avaliando a espessura do filme de líquido na parede do canal. Finalmente, os resultados experimentais e os obtidos a partir das correlações desenvolvidas são comparados com estudos disponíveis na literatura relativos a lâminas com micro canais. / This project involves a theoretical-experimental study of heat transfer and pressure drop in condensation and single phase flow of halogen refrigerants in microchannel tubes. The tests include the pure refrigerant R-134a and quasi azeotropic mixture R-410A. The microchannel tubes tested include one with square ports of Dh = 1,214 mm and other with circular port of Dh = 1,494 mm. The subcooled liquid tests considered the mass velocities of 390 to 1360 kg/sm2, the saturation temperature of 40ºC and subcooled of 10ºC. The condensing tests considered a constant heat flux of 5 kW/m2, vapor quality of 0,15 to 0,9, mass velocities of 410 to 1135 kg/sm2, saturation temperature of 40 to 50ºC and oil-refrigerant mixtures with oil mass concentrations of 0,25 and 0,45%. For each test condition was evaluated the coefficient of heat transfer and frictional pressure drop in the microchannel tube. The single phase results agree with typical correlations used in conventional tubes to evaluate the heat transfer and pressure drop in turbulent flow, even though the most of experimental date are 12% higher. The most of flow patterns in condensation were identified as annular using the flow patterns maps available on literature. This behavior was verified through pressure drop results, which show exclusive dependence on Martinelli Parameter. The heat transfer results show that the main heat transfer mechanism was convective, typical in annular flow. The results of condensation were correlated from empirical approachs using the Martinelli parameter and the equivalent mass velocity concept. And, also a semi-empirical approach modeling the annular flow to evaluate the mechanism of heat transfer through the liquid film around the wall of the tube. Finally, the experimental results and the results obtained through the models were compared with correlations referred to microchannels available on the literature.
66

Perda de carga em filtros de tela e de discos utilizados na irrigação localizada / Loading losses in net and disc filters used in dropping irrigation

Cleomar Ferreira de Oliveira 23 January 2006 (has links)
Os sistemas de irrigação localizada requerem, obrigatoriamente sistemas de filtração para um tratamento mínimo da água. Os filtros são fundamentais à qualidade da água utilizada na agricultura irrigada, promovendo melhor desempenho dos sistemas de irrigação e seus componentes. Neste trabalho, estudou-se a perda de carga em função da vazão, em filtros de tela e de discos e determinou-se a bateria de filtros de mínimo custo anual total para diferentes vazões de projeto. Os ensaios foram realizados no laboratório de irrigação do Departamento de Engenharia Rural da Escola Superior de Agricultura “Luiz de Queiroz”, Universidade de São Paulo, utilizando-se filtros comerciais da marca AMIAD, com elemento filtrantes de tela (modelos 3/4”, 1”, 1 ½” e 2”) de discos (modelos 1”, 1 ½” e 2”). A vazão máxima utilizada no ensaio, para cada modelo de filtro, foi àquela recomendada pelo fabricante. Para todos os filtros analisados no laboratório observaram-se altos valores dos coeficientes de determinação (R2) indicando uma forte relação potencial entre as variáveis vazão e perda de carga. Considerando as condições em que o estudo foi realizado e com base nos resultados obtidos, conclui-se que: o modelo matemático potencial descreve adequadamente a variação da perda de carga nos filtros de tela e discos em função da variação da vazão; os filtros de tela proporcionam menor perda de carga que os filtros de discos; a filtragem da água utilizando filtros de discos apresenta maior custo anual total; para os limites de vazão estudados e para as perdas de carga máximas permitidas, em geral as baterias compostas por filtros de 2” apresentaram o menor custo mínimo anual total; de forma geral, para os filtros estudados, as curvas de perda de carga em função da vazão apresentadas no catálogo do fabricante não representaram fielmente as curvas obtidas nesse trabalho, em ensaio de laboratório. / Drip irrigation systems always require filtration systems for a basic water treatment. The filters are fundamental for the water quality used in irrigated farming, providing better performance of irrigation systems and their components. It was studied in this work the loading loss according to the flow in net and disc filters and it was determined the filter sets with the minimum cost for different flows. The trials were carried out in the irrigation laboratory of the Rural Engineering Department of the Superior School of Agriculture “Luiz de Queiroz”, São Paulo University, using AMIAD brand commercial filters, with net filtration elements (models 3/4”, 1”, 1 ½” ”, and 2”), and discs (models 1”, 1 ½” and 2”).The maximum flow used in the trial, for each filter model, was that recommended by the manufacturer. It was observed for all the analyzed filters in the laboratory high values of determination coefficient (R2) indicating a strong potential relation between the flow and loading loss variables. Considering the conditions in which the study was carried out and based on the results obtained, it was concluded that: The potential mathematical model describes adequately the loading loss variation in the net and disc filters according to the flow variation; the net filters provide less loading loss than the disc filters; the water filtration using disc filters show higher total annual cost; for the studied flow limits and for the maximum allowed loading loss, in general the sets composed of 2” filters present the lowest total annual cost, overall, for the filters studied, the loading loss curves according to the flow showed in the manufacturer’s catalogue did not present accurately the curves obtained on this work in laboratory trial.
67

Análise da velocidade crítica de escoamento e estudo reológico de polpas de caulim da bacia do rio capim em dutos circulares

RUFINO, Romulo Lima January 2009 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-04-07T16:17:44Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseVelocidadeCritica.pdf: 2097878 bytes, checksum: 2379c01cbe0eb00a0164f0ad3cb23583 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-16T14:57:50Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseVelocidadeCritica.pdf: 2097878 bytes, checksum: 2379c01cbe0eb00a0164f0ad3cb23583 (MD5) / Made available in DSpace on 2014-06-16T14:57:50Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseVelocidadeCritica.pdf: 2097878 bytes, checksum: 2379c01cbe0eb00a0164f0ad3cb23583 (MD5) Previous issue date: 2009 / A indústria mineral representa um grande estimulador da economia do estado, e como destaque nessa indústria podemos mencionar o setor do beneficiamento de Caulim. As soluções dos problemas relacionados a essa atividade mostram-se como uma oportunidade rara de interação universidade-indústria, além de ser um campo fértil para o desenvolvimento científico. Um ponto importante a ser estudado trata do escoamento da suspensão de caulim em dutos e equipamentos relacionados; problemas como incrustação e calculo da perda de carga não foram ainda resolvidos de forma definitiva pela indústria. Nesse contexto o presente trabalho se dispõe a desenvolver uma metodologia para o cálculo dos parâmetros de escoamento principalmente da velocidade mínima necessária para que as partículas em suspensão não depositem no interior dos dutos. Assim o objetivo macro desta dissertação reside em analisar através da implementação de metodologia, o cálculo da velocidade de deposição durante o escoamento de polpas de caulim com diferentes frações mássicas (% em peso de sólidos) no interior de dutos circulares; a partir do estudo reológico de amostras obtidas no seu processo de beneficiamento; propiciando assim, subsídio teórico aos técnicos e Engenheiros que desejam dimensionar um sistema de bombeamento aplicado a polpas de caulim; minimizando seus problemas de sub e superdimensionamento, que acarreta a deposição do material, causando danos à produção e meio ambiente, visto que se fará necessário à abertura da tubulação para remoção dos depósitos oriundos da baixa velocidade. / The mineral industry represents a great economy state stimulator, and we can have as that industry highlights the kaolin beneficiation sector. The problem solutions related to that activity is a great opportunity to interact university and industry, besides that it’s a very fertile area to scientific development. A important point to be studied is the kaolin slurry flow inside pipelines and related equipments; problems as incrustation and pipeline pressure drop calculations weren’t still definitely resolved by the industry. In this context the present work consists in develop a methodology to calculate the flow parameters principally the necessary minimum velocity for the suspended particles do not deposit into the pipe. So the main purpose of this dissertation is to analyze, through the methodology implementation, the deposition velocity calculation during the slurry kaolin flow with different mass fraction (% in solid weight) into circular pipelines; from rheological studies done with samples taken from the beneficiation process; there by providing knowledge to the technicians and engineers that desire to design a slurry kaolin pump system; minimizing their problems with sub or super dimensioning, causing material deposition what represents production and environment hazardous whereas it will be necessary to open the pipeline to remove the material deposited due to the low flow velocity.
68

[en] EXPERIMENTAL DETERMINATION OF TRANSPORTATIONS COEFFICIENTS FOR ICE SLURRY IN PLATE HEAT EXCHANGERS / [pt] DETERMINAÇÃO EXPERIMENTAL DOS COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM TROCADORES DE CALOR DE PLACAS

LUIS CARLOS CASTILLO MARTINEZ 25 August 2005 (has links)
[pt] A pasta de gelo é uma mistura de água e um aditivo, com finas partículas de gelo, apresentando uma alta densidade de energia térmica. O principal motivo de sua utilização deve-se à combinação do aproveitamento do calor latente na mudança de fase com capacidade de ser bombeado. O presente trabalho trata do estudo experimental sobre a transfe rência de calor e queda de pressão, com mudança de fase, utilizando uma mistura de propileno glicol - água com 13,8% de concentração em peso, num trocador de calor de placas com arranjo em U para 16 placas. Realizaram-se testes de troca de calor com escoamento em paralelo e contra-corrente, para duas condições de fração mássica de gelo e números de Reynolds para a pasta de gelo entre 150 e 425, com diferentes condições de carga térmica. Dos testes foram observados aumentos de até 25% no coeficiente global de troca calor, ao se incrementar a vazão e, conseqüentemente, o número de Reynolds da pasta de gelo. Com o aumento da fração de gelo melhora-se a capacidade de resfriamento, diminuindo o número de Nusselt da pasta de gelo. O coeficiente global de troca, porém, começa a diminuir. Na literatura esta relação ainda não está bem definida. Alguns autores relatam ganhos, perdas ou indiferença no coeficiente global. Resultados do coeficiente global e do número de Nusselt, nos modos paralelo e contra-corrente, não apresentaram grande diferença. A capacidade de resfriamento em contra-corrente foi maior, apresentando valores de efetividade cerca 10% acima dos resultados observados no modo paralelo. Os fatores de atrito encontrados variaram entre 0,030 a 0,085, o que concorda com os resultados apresentados por outros pesquisadores. Como era de se esperar, o fator de atrito diminui com o aumento da vazão mássica e de maneira inversa com o aumento da fração de gelo. / [en] Ice slurry is an aqueous solution from which ice crystals are formed. These crystals possess high energy density, in the form of latent heat. Furthermore, the fact of being a slurry makes it an excellent energy carrier, for it can be easily pumped. The present work presents an experimental procedure to assess the heat transfer and the pressure loss, with phase change, using a mixture of propyleneglycol and water, 13.8% weight, in a U-plate heat exchanger with 16 plates. Tests were carried out for both parallel and counter-flow configurations of the heat exchanger, for two different mass fractions of ice and with Reynolds numbers between 150 and 425 for the slurry. Different thermal loads were considered. The experiments showed increases of up to 25% in the overall heat transfer coeficiente when the slurry flow is increased, with consequent increase in the Reynolds number. By increasing the ice fraction the cooling capacity is improved, reducing the Nusselt number. In the literature, this relationship is not clearly defined, as some authors show gains in the heat exchange coefficient, losses, and some others did not observe any influence on this parameter. Regarding the heat Exchange configuration, i.e., parallel or counter-flow, neither the heat exchange coefficient, nor the Nusselt number suffered major influence. The effectiveness is up to 10% higher for the counter-flow configuration in comparison with the parallel configuration. The figures found for the friction coefficient, between 0,030 and 0,085, are in good agreement with the literature. As expected, the friction coefficient decreases when the mass flow is increased, and increases when the ice fraction is increased.
69

Metodologia de otimização de redes malhadas através da programação não linear. / Methodology of network optimization through nonlinear programming.

FORMIGA, Klebber Teodomiro Martins. 10 November 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-11-10T14:15:57Z No. of bitstreams: 1 KLEBBER TEODOMIRO MARTINS FORMIGA - DISSERTAÇÃO PPGECA 1999..pdf: 16389709 bytes, checksum: 2cbf1a8342d988c0e6828ecd2fda1b6c (MD5) / Made available in DSpace on 2018-11-10T14:15:57Z (GMT). No. of bitstreams: 1 KLEBBER TEODOMIRO MARTINS FORMIGA - DISSERTAÇÃO PPGECA 1999..pdf: 16389709 bytes, checksum: 2cbf1a8342d988c0e6828ecd2fda1b6c (MD5) Previous issue date: 1999-03-11 / CNPq / As redes de distribuição, que fazem parte dos sistemas de abastecimento de água, são, em grande parte, redes malhadas, cuja complexidade no dimensionamento tem forçado os projetistas a utilizar metodologias tradicionais de tentativa e erro para obter a solução do problema. Esses métodos, dos quais o mais empregado é o de Hardy-Cross, fazem tão somente o balanceamento da rede, deixando a cargo da experiência do projetista a busca de um dimensionamento mais econômico. Neste trabalho será apresentado um método que utiliza técnicas de programação não linear para o dimensionamento económico de redes malhadas. Esse método é composto de duas etapas. Na primeira, as vazões e os diâmetros são considerados como variáveis de decisão, e na segunda etapa, as variáveis de decisão são os comprimentos dos segmentos dos trechos, com diâmetros constantes, e suas correspondentes vazões. Essa metodologia foi aplicada a duas redes encontradas na literatura, em que o dimensionamento já havia sido feito por outros métodos de otimização. Os resultados mostram que o método da programação não linear apresenta uma eficácia maior na busca do custo mínimo de uma rede, quando comparado com outras metodologias de otimização de redes malhadas estudadas. / The design complexity of looped networks has forced to use traditional trial and error methods to attain a solution for the problem. Those methods, where the Hardy-Cross method is the most known among them, only carry out energy and mass balance of the network without dealing with the system's cost, that is, nor estimating neither improving the system's cost. In this work, a method for designing economical looped networks based on nonlinear programming is presented. To reduce the number of variables and, probabily, improve the performance of the solution procedure, this method is composed of two stages to reach an optimal solution. In a first stage, a nonlinear programming technique is applied to determine the flows and diameters of the pipes connecting two nodes of the network. In a second stage are chosen which are the upper and lower values of the results attained at the first stage for each pipe segment, and a nonlinear programming technique is applied once more to determine the length of each diameter for each pipe segment along with its flow. In both stages the objective function was related to the cost of the pipes and pumping requirements. This method has been applied to two examples of looped networks, which have been used in the literature to illustrate the application of other optimization methods developed by other authors. The optimal solutions attained from the method presented herein have shown to be better than the ones resulting from the application of any other method, which were taken into account for comparison in this work.

Page generated in 0.0927 seconds