• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 6
  • 2
  • 1
  • Tagged with
  • 35
  • 20
  • 19
  • 19
  • 12
  • 8
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Assessing the outcome of inner limiting membrane peeling in treating idiopathic epiretinal membrane

Bassiri, Aria 17 June 2016 (has links)
Idiopathic Epiretinal membrane is a proliferation of contractile cells on the surface of the retina that typically occurs after posterior vitreous detachment. Though many questions have been raised on the causes of this condition, a greater debate has been on the treatment of this pathology. The literature suggest the potential benefit in peeling ILM, due to its inherent proliferative characteristics, along with the ERM, during the surgery, however sufficient data has yet to been found. Due to the lack of consensus in treatment of iERM, this study set forth to provide some insight on the surgical outcomes of patients that undergo combined peeling as well attempting to contribute to a potential surgical protocol in treating iERM. This was a retrospective case series study looking at 140 eyes from 126 iERM patients that underwent ERM surgical treatment at Beth Israel Deaconess Medical Center between 1998 and 2015. Pre- and post- operative visual acuities, lens status (phakic, aphakic, pseudophakic), type (kenalog with or without ICG) and duration (0.5min, 1 min, 1.5 min) of the stains used in the procedure, and any prior or successive surgeries were recorded and analyzed. Overall, ERM surgeries demonstrated a significant (p<0.0001) improvement in visual acuity. Furthermore, the combined peel patients demonstrated a significantly (p<0.0467) greater mean change in logMAR score when compared to ERM-only peel procedures. In addition, the combined peel group showed a smaller rate of recurrence. Lastly, simultaneous cataract surgery and the use of ILM stains did not have an impact on the outcome of ERM surgery. The study found that combined (ERM and ILM) peeling along with simultaneous cataract surgery, if a cataract was present, along with the utilization of ILM stains is cost-effective, safe, and effective approach in treating iERM and decreasing its recurrence.
22

Condições do humor aquoso, quanto à contaminação, na facoemulsificação com implante de lente intraocular em cães

Lacerda, Luciana de Cenço Corrêa de [UNESP] 24 January 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-24Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790830.pdf: 1275790 bytes, checksum: ee43ae79b4dc2bfb622479f1f9fcbf29 (MD5) / O tratamento cirúrgico para a catarata, pela facoemulsificação, é atualmente o mais aceito e praticado. A utilização de lentes intraoculares (LIO), indicadas para a correção da emetropia e para a profilaxia da opacificação da cápsula posterior, pode, todavia, ensejar contaminação advinda da cavidade nasal e da conjuntiva palpebral, além do ambiente, da equipe cirúrgica, de materiais e de instrumentais. Com o trabalho, objetivou-se a identificação de linhagens de bactérias presentes nas secreções nasal e conjuntival e no humor aquoso de cães submetidos à facoemulsificação com implante de lentes intraoculares, bem como a caracterização da diversidade genética entre as populações encontradas, empregando-se o sequenciamento da região 16S rDNA de microrganismos, após seleção de diferentes grupos pela Rep-PCR, com o primer BoxA1 associado ao BoxC1R. Encontraram-se bactérias dos gêneros Enterobacter, Staphylococcus, Streptococcus e Pantoea e a espécie Staphylococcus aureus. Pela PCR-RFLP, utilizando-se a enzima MboI, identificaram-se espécies de Staphylococcus, como o S. pseudointermedius. Foram encontrados dois exemplares de Staphylococcus aureus coagulase positivo, pela PCR, confirmados pelo teste bioquímico da coagulase. Os isolados foram submetidos à Rep-PCR com marcadores moleculares Rep1R-I associado ao Rep2, Eric2 e BoxC1R. Encontrou-se alta variabilidade genética entre eles, notadamente quanto ao gênero Staphylococcus. O sequenciamento da região 16S rDNA e a Rep-PCR foram factíveis na detecção da diversidade genética. Oito isolados do gênero Enterobacter em secreção conjuntival e, ao mesmo tempo, no humor aquoso, apresentaram distância genética de 0.000. Cinco por cento dos pacientes submetidos à facoemulsificação com implante de LIO apresentaram contaminação do humor aquoso, por Enterobacter spp / Phacoemulsification is the surgical treatment most commonly performed and accepted for cataracts. The use of artificial intraocular lens (IOL), indicated to achieve emetropy and as an aid on the prophylaxis of posterior capsule opacification, may, however, give rise to contamination arising from the nasal cavity and palpebral conjunctiva, in addition to the environment, the surgical staff, materials and instrumental. The goal of this research was to identify strains of bacteria present in the nasal and conjunctival secretions and aqueous humor of dogs undergoing phacoemulsification with implantation of intraocular lenses, as well as the characterization of genetic diversity among populations found using it sequencing of 16S rDNA of microorganisms, after selection of different groups by Rep-PCR with the primer BoxA1 associated BoxC1R. This study founded genders of bacteria like Enterobacter, Staphylococcus, Streptococcus and Pantoea and Staphylococcus aureus species. PCR-RFLP, using the enzyme MboI, identified Staphylococcus species such as S. pseudointermedius. Two copies of coagulase positive Staphylococcus aureus, founded by PCR, were confirmed by biochemical coagulase test. All of isolates was submitted by Rep-PCR with molecular markers Rep1R-I associated with Rep2, Eric2 and BoxC1R. It was found high genetic variability among them, especially regarding the gender Staphylococcus. Sequencing of 16S rDNA and Rep-PCR were effective in detecting genetic diversity. Eight isolates of gender Enterobacter in the conjunctival secretion and, at the same time, in aqueous humor, showed genetic distance of 0.000. Five percent of patients submitted to phacoemulsification with IOL implantation showed contamination in aqueous humor, by Enterobacter spp
23

Condições do humor aquoso, quanto à contaminação, na facoemulsificação com implante de lente intraocular em cães /

Lacerda, Luciana de Cenço Corrêa de. January 2014 (has links)
Orientador: José Luiz Laus / Coorientador: Renato Pariz Maluta / Banca: Paola Castro Moraes / Banca: Cristiane dos Santos Honsho / Resumo: O tratamento cirúrgico para a catarata, pela facoemulsificação, é atualmente o mais aceito e praticado. A utilização de lentes intraoculares (LIO), indicadas para a correção da emetropia e para a profilaxia da opacificação da cápsula posterior, pode, todavia, ensejar contaminação advinda da cavidade nasal e da conjuntiva palpebral, além do ambiente, da equipe cirúrgica, de materiais e de instrumentais. Com o trabalho, objetivou-se a identificação de linhagens de bactérias presentes nas secreções nasal e conjuntival e no humor aquoso de cães submetidos à facoemulsificação com implante de lentes intraoculares, bem como a caracterização da diversidade genética entre as populações encontradas, empregando-se o sequenciamento da região 16S rDNA de microrganismos, após seleção de diferentes grupos pela Rep-PCR, com o primer BoxA1 associado ao BoxC1R. Encontraram-se bactérias dos gêneros Enterobacter, Staphylococcus, Streptococcus e Pantoea e a espécie Staphylococcus aureus. Pela PCR-RFLP, utilizando-se a enzima MboI, identificaram-se espécies de Staphylococcus, como o S. pseudointermedius. Foram encontrados dois exemplares de Staphylococcus aureus coagulase positivo, pela PCR, confirmados pelo teste bioquímico da coagulase. Os isolados foram submetidos à Rep-PCR com marcadores moleculares Rep1R-I associado ao Rep2, Eric2 e BoxC1R. Encontrou-se alta variabilidade genética entre eles, notadamente quanto ao gênero Staphylococcus. O sequenciamento da região 16S rDNA e a Rep-PCR foram factíveis na detecção da diversidade genética. Oito isolados do gênero Enterobacter em secreção conjuntival e, ao mesmo tempo, no humor aquoso, apresentaram distância genética de 0.000. Cinco por cento dos pacientes submetidos à facoemulsificação com implante de LIO apresentaram contaminação do humor aquoso, por Enterobacter spp / Abstract: Phacoemulsification is the surgical treatment most commonly performed and accepted for cataracts. The use of artificial intraocular lens (IOL), indicated to achieve emetropy and as an aid on the prophylaxis of posterior capsule opacification, may, however, give rise to contamination arising from the nasal cavity and palpebral conjunctiva, in addition to the environment, the surgical staff, materials and instrumental. The goal of this research was to identify strains of bacteria present in the nasal and conjunctival secretions and aqueous humor of dogs undergoing phacoemulsification with implantation of intraocular lenses, as well as the characterization of genetic diversity among populations found using it sequencing of 16S rDNA of microorganisms, after selection of different groups by Rep-PCR with the primer BoxA1 associated BoxC1R. This study founded genders of bacteria like Enterobacter, Staphylococcus, Streptococcus and Pantoea and Staphylococcus aureus species. PCR-RFLP, using the enzyme MboI, identified Staphylococcus species such as S. pseudointermedius. Two copies of coagulase positive Staphylococcus aureus, founded by PCR, were confirmed by biochemical coagulase test. All of isolates was submitted by Rep-PCR with molecular markers Rep1R-I associated with Rep2, Eric2 and BoxC1R. It was found high genetic variability among them, especially regarding the gender Staphylococcus. Sequencing of 16S rDNA and Rep-PCR were effective in detecting genetic diversity. Eight isolates of gender Enterobacter in the conjunctival secretion and, at the same time, in aqueous humor, showed genetic distance of 0.000. Five percent of patients submitted to phacoemulsification with IOL implantation showed contamination in aqueous humor, by Enterobacter spp / Mestre
24

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser /

Conceição, Luciano Fernandes da. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Adriana Morales / Banca: João Antônio Tadeu Pigatto / Banca: Paola Castro Moraes / Banca: Luis Gustavo Gosuen Gonçalves Dias / Resumo: A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Abstract: Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher's exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ... / Doutor
25

Estudo comparativo da sensação dolorosa em pacientes submetidos à facoemulsificação com diferentes temperaturas da solução de irrigação ocular / Comparative study of pain sensation in patients undergoing phacoemulsification with different temperatures of ocular irrigation solution

Ricardo Hélio Biaggi 18 October 2013 (has links)
O presente estudo objetivou comparar a eficácia analgésica entre dois tipos de técnicas anestésicas (tópica e tópica associada a crioanalgesia) utilizadas para realização da cirurgia de catarata. Vinte e cinco pacientes com catarata senil em ambos os olhos, classificadas de acordo com o critério de LOCS III em NO3 NC3 e NO4 NC4, acuidade visual inferior a 20/40 e indicação cirúrgica foram randomizados para serem submetidos à facoemulsificação com uso de solução de irrigação ocular em temperatura ambiente (23°C) em um olho (Grupo 1; n = 25) e gelada (4°C) no olho contralateral (Grupo 2; n = 25). A dor do procedimento foi avaliada através do uso de escala analógica visual 15 minutos após a realização da facoemulsificação. Esta escala varia de 0 a 100, onde o ponto 0 representa nenhuma dor e 100 representa a dor mais intensa que poderia ter sentido durante todo o procedimento cirúrgico. A perda celular endotelial, a variação da espessura corneana e o ganho de visão foram avaliados 30 ± 2 dias após cada cirurgia. A média da dor no Grupo 1 foi de 26.02 (DP=18.58) e no Grupo 2 foi de 21.28 (DP=18.20). Os valores das medianas da dor relacionada ao procedimento nos grupos 1 e 2 foram, respectivamente, 22.5 (0 66.5) e 17 (0 75.5). Após um mês de acompanhamento, a perda média de células endoteliais foi de 10% e 9.88% respectivamente, não havendo diferença estatisticamente significativa entre os grupos (teste de Wilcoxon). Não houve correlação estatisticamente significativa entre os valores médios de tempo de cirurgia, volume de irrigação, tempo de ultrassom, poder de ultrassom e ganho de visão com a perda celular ou com o escore de dor (análise de correlação de mínimos quadrados). O estudo demonstrou que não houve diferença no controle da intensidade da dor durante o procedimento de facoemulsificação com o uso de anestesia tópica ou anestesia tópica associada à crioanalgesia. / The study aimed to compare the analgesic efficacy between two types of anesthetic techniques (topical and topical associated with cryoanalgesia) during cataract surgery. Twenty-five patients with senile bilateral cataract, classified in NO3 NC3 and NO4 NC4 according to LOCS III criteria, visual acuity less than 20/40 and surgical indication were randomized to undergo phacoemulsification with the use of ocular irrigation solution at room temperature (23°C) for an eye (Group 1, n = 25) and cold solution in the contralateral eye (Group 2, n = 25). The pain of the procedure was assessed by using a visual analogue scale 15 minutes after the completion of phacoemulsification. This scale ranges from 0 to 100, being the point \"0\" representation of \"no pain\" and \"100\" the \"worst pain you might have felt\" throughout the surgical procedure. Endothelial cell loss, change in corneal thickness and vision improvement were evaluated 30 ± 2 days after each surgery. Operation time, irrigation volume, ultrasound time and ultrasound power were related to cell loss between groups. Mean pain in Group 1 was 26.02 (SD=18.58) and in Group 2 was 21.28 (SD=18.20). Median (range) pain related to the procedure in groups 1 and 2 were, respectively, 22.5 (066.5) and 17 (075.5). After one month follow-up, the mean endothelial cell loss was 10% and 9.88% respectively, with no statistical difference between groups. There were no statistically significant correlation between surgery time, irrigation volume, ultrasound time, ultrasound power and vision improvement means with cell loss or pain scores (bivariate fit). Study showed no difference in controlling the intensity of pain during phacoemulsification with the use of topical anesthesia or topical anesthesia associated with cryoanalgesia.
26

Validação de um procedimento operacional padrão para processamento das vias de irrigação e aspiração do kit de facoemulsificação / Validation of a standard operating procedure for reprocessing of the tubings of phacoemulsification kit.

Alda Graciele Claudio dos Santos Almeida 24 February 2014 (has links)
Introdução: Processar seguramente os dispositivos cirúrgicos reutilizáveis é um cuidado indireto de Enfermagem do Centro de Material e Esterilização. Muitos desses dispositivos apresentam conformação complexa que dificulta a limpeza, deixando dúvidas quanto ao alcance da esterilidade, ausência de biofilmes e endotoxinas. Entre os produtos utilizados em cirurgia para extração de catarata por facoemulsificação, as vias de irrigação e aspiração são materiais com alto risco de ocasionar endoftalmite ou síndrome tóxica do segmento anterior ocular no próximo usuário. Feitas de silicone, possuem lúmen de diâmetro com 1 a 2,5 mm e comprimento de 1,85 a 2,00 m, configurando-se em material de difícil processamento. Seus fabricantes não apresentam protocolos validados para seu processamento, o que constitui um grave problema de segurança ao paciente. Objetivo: Validar um Procedimento Operacional Padrão (POP) para processamento das vias de irrigação e aspiração do kit de facoemulsificação. Método: Esta pesquisa caracterizou-se, como um estudo laboratorial, utilizando contaminação-desafio. O POP foi elaborado com base no referencial teórico científico atual e na legislação pertinente. Como corpos de prova foram usados tubos de silicone, reproduzindo as dimensões do lúmen e do comprimento das vias de irrigação e aspiração. A análise foi feita por meio da espectroscopia de infravermelho que validou a equivalência da matéria-prima dos corpos de prova ao dispositivo original. Como contaminação-desafio, foi utilizada uma suspensão de Pseudomonas aeruginosa - ATCC 27853 106 UFC/mL acrescida de 20% de albumina humana em meio de cultura enriquecido de Tryptic Soy Broth (TSB) com solução salina balanceada. Para a contaminação dos corpos de prova, foram injetados 3 mL do contaminante desafio no lúmen dos corpos de prova de 1 mm e 7mL nos de 2 mm de diâmetro, e deixados de 1 a 17 horas. Em seguida, estes foram submetidos ao POP proposto. Como desfecho intermediário, foi avaliada a eficácia da limpeza (n=30) com teste de bioluminescência (Clean-Trace ATP water test, 3M®). A eficácia da esterilização (n=30) foi avaliada por meio da inoculação direta dos corpos de prova em TSB, e a detecção das endotoxinas (n=30), utilizando kit cinético-turbidimétrico. Os experimentos foram acompanhados por grupos controles positivo (n=3) e negativo (n=3). Resultados: a média de ATP obtida após a aplicação do POP de limpeza, expressa em RLUs, foi de 5,25 RLUs para os corpos de prova de 1 mm de diâmetro e 4,40 RLUs para os de 2 mm. A redução da quantidade média de ATP em RLUs foi de 98,5% a 99,98% respectivamente, para os tempos de contato com o contaminante desafio de 1 e 17h. Quanto à quantidade da endotoxina, esta variou de <0,01 UE/mL a 0,0192 UE/mL. Não houve recuperação do micro-organismo teste em nenhuma das amostras do grupo pesquisado. Os resultados dos controles positivo e negativo foram satisfatórios. Conclusão: Os resultados demonstraram que o POP proposto assegura o processamento das vias de irrigação e aspiração do kit de facoemulsificação. Esta conclusão não deve ser extrapolada para os reusos consecutivos autorizados pelos fabricantes, sem a realização de novos testes até o número máximo de reusos permitidos, justificado pelo fato da superfície dos lumens poderem ser alteradas a cada processamento. / Introduction: Reprocessing safely reusable surgical devices is an indirect nursing care in the Material and Sterilization Center. Many of these devices have complex geometry forms which difficult the cleaning process, leaving doubts about the scope of sterility and absence of biofilms and endotoxin. Among the products used in surgery for cataract extraction by phacoemulsification, the tubings of phacoemulsification machine are the materials with a high risk of causing endophthalmitis or toxic anterior segment syndrome in the next patient. Made of silicon, have a lumen diameter of 1 to 2.5 mm and a length of 1.85 to 2.00 m, and configuring itself in difficult materials to reprocessing. The manufacturers of these materials dont present validated protocols for reprocessing, which is a serious problem to the safety of the patient. Objective: To validate a standard operating procedure for reprocessing of the tubings of phacoemulsification machine. Method: This research was characterize as a laboratory study using test soil. The standard protocol was based on current scientific theoretical reference and relevant legislation. Silicone tubes reproducing lumen dimensions and the length of the original tubings of phacoemulsification machine were used as specimens. The analysis by infrared spectroscopy validated the equivalence of the primal material of the specimens to the original device. It was a test soil with Pseudomonas aeruginosa (ATCC 27853) 106 UFC/mL plus 20% human albumin in culture medium supplemented Tryptic Soy Broth (TSB) with balanced salt solution. To contamination of the samples were injected 3 to 7 mL of the test soil in the lumen and left for 1 and 17 hours. Then, these were submitted to the proposed standard protocol. As an intermediate outcome, the cleaning efficiency (n=30) was evaluated with bioluminescence test (Clean-Trace ATP water test, 3M®). The sterilization efficacy (n=30) was evaluated by direct inoculation specimens of silicone tubes in TSB, and the detection of endotoxin (n=30) using kinetic turbidimetric assay. The experiments were accompanied by positive control group (n=3) and negative (n=3). Results: The average ATP obtained after application of standard protocol cleaning, expressed in RLUs, was 5.25 RLUs for the specimens of silicone tubes of 1 mm in diameter and 4.40 RLUs to them 2 mm in diameter. The decrease in the average measure of ATP in RLUs was 98.5% to 99.98%, respectively for the periods of contact with the contaminant of 1h and 17h. As amount of endotoxin that ranged of <0.01 EU/mL to 0.0192 EU/mL. There wasnt recovery of the test microorganism in the samples of the group studied. The results of positive and negative controls were satisfactory. Conclusion: The results demonstrate that proposed standard protocol ensures the reprocessing of tubings of phacoemulsification machine. This conclusion should not be extrapolated to consecutive reuses authorized by the manufacturers without retest until the maximum number of allowed reuses justified by the fact that surface of the lumens can be changed at each reprocessing.
27

Variación de la función visual y calidad de vida en pacientes con cataratas antes y después de la Facoemulsificación con colocación de lente intraocular en Lima-Perú

Luján Paredes, Silvio Augusto 20 January 2016 (has links)
Objetivo: Determinar la variación de la función visual y calidad de vida en pacientes con cataratas antes y después de la facoemulsificación más colocación de LIO. Métodos: Estudio longitudinal en pacientes mayores de 50 años, intervenidos de catarata con la cirugía de facoemulsificación con colocación de LIO. Se evaluó la variación de la función visual con el VFQ 25 y la calidad de vida con el QOL.Q 40 antes de la intervención quirúrgica y luego de 3 meses. Resultados: La edad media de los pacientes fue de 74 años ± 7,4, 55%, de los cuales 37,5% tuvieron una cirugía previa de cataratas. Se evidenció una variación favorable de la función visual en las subescalas de Salud general (p<0,001), Visión General (p< 0,001), Visión de cerca (p= <0,001), Visión de lejos (p< 0,001), Limitaciones (p= 0,001) y Visión Periférica (p< 0,001). La calidad de vida medida con el QOLQ.40, también presentó cambio favorable evidenciándose una diferencia significativa en la subescala de Satisfacción con un (p=0,0001.). Se calculó la correlación entre la variación de la función visual medida con el VFQ 25 y la variación del número de células endoteliales, hallando una mejora en la subescala de “Limitación” con un rho de Spearman de 0.3456. Conclusión: Los pacientes presentaron respuesta favorable a la intervención tanto a nivel clínico, observando un incremento de la agudeza visual, como en la función visual y calidad vida. Los cuestionarios de calidad de vida son adaptables a nuestra población, su uso permitirá una medición integral de los resultados de la cirugía. / Tesis
28

Long-term outcome after cataract surgery a longitudinal study /

Lundqvist, Britta, January 2009 (has links)
Diss. (sammanfattning) Umeå : Umeå universitet, 2010. / Härtill 4 uppsatser. Även tryckt utgåva.
29

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff / Evaluation of patients' visual acuity and quality of life after bilateral implantation of multifocal intraocular lens EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de 22 February 2018 (has links)
Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T13:33:12Z No. of bitstreams: 1 Dissertação corrigida.docx: 1063474 bytes, checksum: a294630584043d85364c1994f91ac26e (MD5) / Rejected by Luciana Pizzani null (luciana@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: o arquivo submetido deve, obrigatoriamente, estar em formato PDF. Seu arquivo está em word. Assim que tiver efetuado essa correção submeta o arquivo, em PDF, novamente. Agradecemos a compreensão. on 2018-04-13T17:52:53Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T20:18:43Z No. of bitstreams: 2 Dissertação corrigida.pdf: 3450020 bytes, checksum: c8bca522995d10e2ee7b7d957bd1b67c (MD5) Ficha catalográfica.pdf: 196557 bytes, checksum: 0a1da60dbc50589c50298c259a920c52 (MD5) / Rejected by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: arquivos separados (dissertação e ficha catalográfica) O arquivo deve ser único e a ficha catalográfica deve ser inserida no arquivo PDF logo após a folha de rosto do seu trabalho. Assim que tiver efetuado a correção ou correções submeta o arquivo em PDF novamente. Agradecemos a compreensão. on 2018-04-17T13:29:17Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-17T19:51:20Z No. of bitstreams: 1 Dissertação corrigida c ficha cat (1).pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2018-04-19T12:13:23Z (GMT) No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Made available in DSpace on 2018-04-19T12:13:23Z (GMT). No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) Previous issue date: 2018-02-22 / RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fotópicas. A curva de defocus mostrou adição de +2,50 no plano dos óculos. A sensibilidade ao contrate esteve no nível inferior da normalidade para frequências espaciais baixas e altas e abaixo do nível mínimo em frequências intermediárias. A media geral das avaliações no questionário de qualidade de vida foi de 91. Conclusão: conclui-se que o implante da LIO multifocal proporcionou bons resultados no que se refere à AV pós-operatória, além de maior independência dos óculos e melhora da qualidade de vida. / ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average score of 91. Conclusion: in conclusion, multifocal IOL implant provided good results for post-operative VA, in addition to greater spectacle independence and quality of life improvement.
30

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de January 2018 (has links)
Orientador: Antonio Carlos Lottelli Rodrigues / Resumo: RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average scor... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0794 seconds