• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 13
  • 12
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 132
  • 132
  • 74
  • 33
  • 31
  • 30
  • 26
  • 26
  • 22
  • 22
  • 20
  • 20
  • 20
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Electrochemical Storage of Lithium in Silicon - Morphological Analysis from the Atomistic Scale to the Macroscale

Ronneburg, Arne 26 May 2021 (has links)
Die experimentellen Daten können bei Dr. Sebastian Risse, Helmholtz-Zentrum Berlin, eingesehen werden. / Silizium-Elektroden werden aufgrund ihrer um eine Gröÿenordnung höheren Kapazität als mögliches Elektrodenmaterial in Lithium-Ionen-Batterien betrachtet. Diese Kapazität geht jedoch mit einer Volumenausdehnung von bis zu 310 % einher. Dies begünstigt einen schnellen Kapazitätsabfall und ein kontinuierliches Wachstum der SEI-Schicht. Ziel dieser Arbeit ist es daher, die Morphologie-Änderung der Siliziumelektrode während des Lithiierungs-Prozesses besser zu verstehen unter Nutzung von operando-Methoden Im ersten Teil wurde Neutronenreflektometrie (NR) genutzt, um die Morphologie-Änderung auf der Nanometerskala einer Siliziumelektrode zu untersuchen. Das Wachsen/Schrumpfen der lithiierten Zone im Silizium wurde beobachtet. Auf der Oberfläche der Elektrode wächst im delithiierten Zustand eine Grenzschicht, welche die Lithiierung verhindert. Nachdem diese Schicht aufgelöst ist, kann Lithium eingelagert werden. Im zweiten Teil wurde operando Röntgen- Phasenkontrast-Radiographie genutzt. Ein rechteckiges Riss-Gitter wurde dabei im delithiierten Zustand beobachtet, welches sich während der Lithiierung schließt. Dieses Gitter ist entlang der Kristallachsen des Siliziums orientiert. Im nächsten Zyklus entsteht das Gitter am selben Ort wieder, und breitet sich mit steigender Zyklenzahl über die Elektrode aus. Im dritten Teil wurde der Einfluss einer künstlichen Grenzschicht auf die Lithiierung untersucht. Erneut wurde NR genutzt. Die künstliche Schicht verringert das Wachstum der SEI-Schicht, unterdrückt es jedoch nicht komplett. Nach 2 Zyklen ist die Grenzschicht degradiert, und Seitenreaktionen können beobachtet werden. / Silicon electrodes receive great interest as potential electrode material in lithium-based batteries due to their one order of magnitude higher capacity. This is accompanied by a volume expansion of up to 310 %, leading to an accelerated capacity loss of the electrodes. The volume expansion creates mechanical stress, leading to fracturization of the electrode and the continuous growth of the solid-electrolyte-interphase (SEI) layer under the consumption of active material. The aim of this thesis is to investigate the morphological changes of silicon electrodes during lithiation/ delithiation. Especially operando-techniques are well-suited to investigate these morphological changes since they allow us to precisely link structural data and the electrochemical state. The first project uses operando neutron reflectometry (NR) and in-situ electrochemical impedance spectroscopy (EIS) to analyze the morphology change of the silicon surface on the nanometer-scale. The growth and shrinkage of the lithiated layers within the electrode as well as the lithium concentration was determined with this method. An SEI-layer forms on top of the silicon electrode in the delithiated state, which hinders the lithium uptake in the initial part of the subsequent lithiation. The second project analyzes the morphology-change of the electrode on the µm-scale. Here the fracturization of the silicon electrode is investigated by operando X-ray phase-contrast radiography. A rectangular fracturization pattern was observed during the second half of the delithiation, which vanished again during the lithiation. The third project investigates the influence of an artificial coating layer on the lithiation process. Again operando NR was chosen as analysis tool. The artificial coating decreased the formation of the SEI-layer within the first cycles, but did not suppress it completely. However, this layer degraded already in an early stage of cycling, resulting in the occurrence of side reactions afterward.
112

Aqueductal cerebrospinal fluid pulsatility in healthy individuals is affected by impaired cerebral venous outflow

Beggs, Clive B., Magnano, C.R., Shepherd, Simon J., Marr, K., Valnarov, V., Hojnacki, D., Bergsland, N., Belov, P., Grisafi, S., Dwyer, Michael G., Carl, Ellen, Weinstock-Guttman, B., Zivadinov, R. 08 November 2013 (has links)
yes / To investigate cerebrospinal fluid (CSF) dynamics in the aqueduct of Sylvius (AoS) in chronic cerebrospinal venous insufficiency (CCSVI)-positive and -negative healthy individuals using cine phase contrast imaging. Materials and Methods Fifty-one healthy individuals (32 CCSVI-negative and 19 age-matched CCSVI-positive subjects) were examined using Doppler sonography (DS). Diagnosis of CCSVI was established if subjects fulfilled ≥2 venous hemodynamic criteria on DS. CSF flow and velocity measures were quantified using a semiautomated method and compared with clinical and routine 3T MRI outcomes. Results CCSVI was associated with increased CSF pulsatility in the AoS. Net positive CSF flow was 32% greater in the CCSVI-positive group compared with the CCSVI-negative group (P = 0.008). This was accompanied by a 28% increase in the mean aqueductal characteristic signal (ie, the AoS cross-sectional area over the cardiac cycle) in the CCSVI-positive group compared with the CCSVI-negative group (P = 0.021). Conclusion CSF dynamics are altered in CCSVI-positive healthy individuals, as demonstrated by increased pulsatility. This is accompanied by enlargement of the AoS, suggesting that structural changes may be occurring in the brain parenchyma of CCSVI-positive healthy individuals
113

Studies of Stented Arteries and Left Ventricular Diastolic Dysfunction Using Experimental and Clinical Analysis with Data Augmentation

Charonko, John James 04 May 2009 (has links)
Cardiovascular diseases are among the leading causes of deaths worldwide, but the fluid mechanics of many of these conditions and the devices used to treat them are only partially understood. This goal of this dissertation was to develop new experimental techniques that would enable translational research into two of these conditions. The first set of experiments examined <i>in-vitro</i> the changes in Wall Shear Stress (WSS) and Oscillatory Shear Index (OSI) caused by the implantation of coronary stents into the arteries of the heart using Particle Image Velocimetry. These experiments featured one-to-one scaling, commercial stents, and realistic flow and pressure waveforms, and are believed to be the most physiologically accurate stent experiments to date. This work revealed distinct differences in WSS and OSI between the different stent designs tested, and showed that changes in implantation configuration also affected these hemodynamic parameters. Also, the production of vortices near the stent struts during flow reversal was noted, and an inverse correlation between WSS and OSI was described. The second set of experiments investigated Left Ventricular Diastolic Dysfunction (LVDD) using phase contrast magnetic resonance imaging (pcMRI). Using this technique, ten patients with and without LVDD were scanned and a 2D portrait of blood flow through their heart was obtained. To augment this data, pressure fields were calculated from the velocity data using an omni-directional pressure integration scheme coupled with a proper-orthogonal decomposition-based smoothing. This technique was selected from a variety of methods from the literature based on an extensive error analysis and comparison. With this coupled information, it was observed that healthy patients exhibited different flow patterns than diseased patients, and had stronger pressure differences during early filling. In particular, the ratio of early filling pressure to late filling pressure was a statistically significant predictor of diastolic dysfunction. Based on these observations, a novel hypothesis was presented that related the motion of the heart walls to the observed flow patterns and pressure gradients, which may explain the differences observed clinically between healthy and diseased patients. / Ph. D.
114

Advances in real-time phase-contrast flow MRI and multi-echo radial FLASH

Tan, Zhengguo 26 April 2016 (has links)
No description available.
115

Mesure de pression non-invasive par imagerie cardiovasculaire et modélisation unidimensionnelle de l’aorte / Non-invasive pressure measurement using cardiovascular MRI and one-dimensional modelling of the aorta

Khalifé, Maya 12 December 2013 (has links)
L'imagerie par Résonance Magnétique permet de mesurer l'écoulement sanguin. Au niveau cardiovasculaire, elle permet d'acquérir non seulement des images anatomiques du cœur et des gros vaisseaux mais aussi des images fonctionnelles de vitesse par contraste de phase. Cette technique offre des perspectives dans l'étude de la dynamique des fluides et dans la caractérisation des artères, en particulier pour les grosses artères systémiques comme l'aorte dont le rôle est primordial dans la circulation sanguine. Par ailleurs, l'un des paramètres qui entrent en jeu dans la détermination de la fonction cardiaque et du comportement vasculaire est la pression artérielle. La méthode de référence de la mesure de pression dans l'aorte étant le cathétérisme, plusieurs méthodes combinant la modélisation à l'imagerie ont été proposées afin d'estimer un gradient de pression de façon non invasive. Ce travail de thèse propose de mesurer la pression dans un segment d'aorte grâce à un modèle 1D simplifié et en utilisant les données mesurées par IRM et un modèle 0D représentant le réseau vasculaire périphérique comme conditions aux limites. Aussi, afin d'adapter le modèle à l'aorte du patient, une loi de pression exprimant une relation entre la section aortique à la pression et basée sur la compliance a été utilisée. Cette dernière, liée à la vitesse d'onde de pouls (VOP), a été mesurée en IRM sur les ondes de vitesse.Par ailleurs, les séquences de codage de vitesse et d'accélération sont longues et ponctuées d'artéfacts dus au mouvement du patient. Une apnée est requise afin de limiter le mouvement respiratoire. Cependant, la durée de l'apnée atteint 25 à 30 secondes pour de telles séquences, ce qui est souvent impossible à tenir pour les malades. Une technique d'optimisation de séquences dynamiques par réduction du champ de vue est proposée et étudiée. La technique décrit un dépliement des régions repliées par différence complexe de deux images, l'une codée et l'autre non codée en vitesse. Cette méthode réalise une réduction de plus de 25% de la durée d'apnée. / Magnetic Resonance Imaging (MRI) is used to measure blood flow. It allows assessing not only dynamic images of the heart and the large arteries, but also functional velocity images by means of Phase Contrast. This promising technique is important for studying fluid dynamics and characterizing the arteries, especially the large systemic arteries that play a prominent role in the blood circulation. One of the parameters used for determining the cardiac function and the vascular behavior is the arterial pressure. The reference technique for measuring the aortic pressure is catheterism, but several methods combining imaging and mathematical modeling have been proposed in order to non-invasively estimate a pressure gradient. This work proposes to measure pressure in an aortic segment through a simplified 1D model using MRI measured flow and 0D model representing the peripheral vascular system as boundary conditions. To adapt the model to the aorta of a patient, a pressure law was used forming a relation between the aortic section area and pressure, based on compliance, which is linked to pulse wave velocity (PWV) estimated on MRI measured flow waves.Scan duration was optimized, as it is often a limitation during image acquisition. Velocity and acceleration sequences require a long time and may cause artifacts. Hence, they are acquired during apnea to avoid respiratory motion. However, for such acquisitions, a subject would have to hold their breath for more than 25 seconds which can pose difficulties for some patients. A technique that allows dynamic acquisition time optimization through field of view reduction was proposed and studied. The technique unfolds fold-over regions by complex difference of two images, one of which is motion encoded and the other acquired without an encoding gradient. By implementing this method, we decrease the acquisition time by more than 25%
116

Preuve de concept in vitro de la navigation par résonance magnétique en conditions physiologiquement réalistes

Michaud, François 12 1900 (has links)
No description available.
117

Le contenu de l'angle ponto-cérébelleux : artères et mouvements : morphogenèse, anatomie statique et dynamique / Cerebello-pontine angle content : Motions and arteries : Morphogenesis, static and dynamic anatomy

Labrousse, Marc 10 November 2011 (has links)
Différents éléments vasculo-nerveux participent à la constitution de l'angle ponto-cérébelleux. Dans certaines conditions pathologiques dont la genèse est encore imparfaitement connue actuellement, des conflits peuvent apparaître entre des vaisseaux battants autour du tronc cérébral et des nerfs crâniens. L'objectif de ce travail en trois parties distinctes est consacré à certaines bases anatomiques et physiologiques permettant de mieux appréhender ces conflits vasculo-nerveux. La première partie s'intéresse à la morphogenèse du système vertébrobasilaire. La conception d'un logiciel original de reconstruction tridimensionnelle a permis la modélisation de quatre embryons à partir de coupes histologiques. Les images obtenues permettent de confirmer la morphogenèse décrite dans la littérature et jette les bases d'une étude plus exhaustive. La deuxième partie démontre pour la première fois la mobilité physiologique du nerf vestibulo-cochléaire au niveau de l'angle ponto-cérébelleux, par l'utilisation d'une séquence IRM en contraste de phase. Les directions crânio-caudale et antéro-postérieure et leur amplitude ont été étudiées. Ces mouvements sont dépendants de l'onde de pouls. De façon plus générale, ils peuvent être modélisés sous la forme d'une corde oscillant entre le tronc cérébral et le fond du méat acoustique interne. La troisième partie traite d'une étude de faisabilité qui jette les bases informatiques permettant d'apprécier le vieillissement artériel par la variabilité morphologique du point de confluence des artères vertébrales. Au laboratoire, nous avons conçu un programme de normalisation à partir des scanographies de neuf patients. Il autorise ainsi la création d'un tronc cérébral moyen, et la comparaison de la topographie de ces points de confluence. / Several vascular and nervous structures are located within the cerebello-pontine angle. In certain pathological conditions, microvascular compression syndroms may occur, where an artery or a vein is compressing a cranial nerve. The purpose of this work in three parts is to investigate some anatomical and physiological bases of these microvascular compression syndroms. The first part focuses on the vertebrobasilar system morphogenesis. A special designed 3D reconstruction original software allowed us to reformate four human embryos from histological serial sections. The three-dimensional views are confirming the classical features thus creating the basis of a larger study based on multiple embryos. The second part shows for the first time the physiological motion of the vestibulo-cochlear nerve at the level of the cerebello-pontine angle, with the help of a phase-contrast MRI sequence. The cranio-caudal and antero-posterior directions and their amplitudes have been studied. These motions are cardiac-cycle-dependant. We used an "oscillating string" model to explain the VCN motion between the brain stem and the fundus of the internal acoustic meatus. The third part of this work is focused on a preliminary study of the variability of the vertebro-basilar arterial fusion along the lifetime. An original software has been designed and allowing the normalisation from nine post-contrast cerebral CT scanners. A ?mean? brain stem was obtained and visualized in front of nine arterial fusion points.
118

Interférométrie X à réseaux pour l'imagerie et l'analyse de front d'ondes au synchrotron / Synchrotron X-ray grating interferometry for imaging and wavefront sensing

Zanette, Irène 16 December 2011 (has links)
Le sujet de cette thèse est l'interférométrie X à réseaux: une technique d’imagerie développée pour la première fois il y a quelques années et qui donne des images de phase et de diffusion (small angle X-ray scattering) de haute sensibilité. Cette technique a un potentiel considérable pour la visualisation du structures qui absorbent faiblement les rayons X, et pour la détection de détails plus petits que la résolution du détecteur, par exemple les fissures et les fibres. Des structures de ce type ne peuvent pas être visualisées avec l’imagerie conventionnelle à rayons X en absorption. Dans le cadre des travaux sur cette thèse, un interféromètre à réseau à rayons X pour radiographie et tomographie multimodale a été installé à la ligne de lumière ID19 de l‘European Synchrotron Radiation Facility à Grenoble, France. L’excellente performance de cet instrument a été démontrée sur une grande variété d'échantillons de tissus biologiques mous, sur des échantillons paléontologiques, et sur des tissus osseux. Une autre partie des ce travail porte sur des améliorations de la technique d’imagerie elle-même. La première des ces améliorations consiste en un développement de méthodes avancées pour la tomographie avec réseaux. Ces méthodes peuvent réduire considérablement la dose livrée à l’échantillon durant les mesures nécessaires pour la reconstruction tomographique tout en préservant la qualité d’image. Un autre résultat majeur dans le cadre de ce travail est la conception, la mise en oeuvre et la démonstration d’un interféromètre à réseau à deux dimensions (2D). Cet appareil utilise des réseaux bidimentionnels au lieu de réseaux linéaires. L’interféromètre 2D produit des cartes d'angles de réfraction et des images de type champ sombre dans plusieurs directions du plan d’image et améliore considérablement la qualité des radiographies à réseau. Le champ d’application de l’interféromètre 2D n’est pas limité à l'imagerie par rayons X, puisque le nouveau dispositif peut aussi être particulièrement utile pour la caractérisation de composantes optiques de haute précision, tel que démontré par des expériences de métrologie à la longueur d'onde d'utilisationsur des lentilles réfractives pour rayons X. / The subject of this thesis is X-ray grating interferometry: an imaging technique first demonstrated a few years ago, which yields high-sensitivity phase and dark-field (small angle X-ray scattering) images of the investigated specimen. It bears tremendous potential for the visualization of low-absorbing features, and for the detection of details smaller than the resolution of the imaging system, such as cracks and fibers. Structures of this type cannot be visualized with conventional absorption X-ray imaging. As a part of this thesis work, an X-ray grating interferometer for multimodal radiography and tomography was installed at the beamline ID19 of the European Synchrotron Radiation Facility in Grenoble, France. The excellent performance of this instrument has been demonstrated on a large variety of soft-tissue biological samples, on paleontological specimens, and on osseous tissues. Another part of the present work concerns improvements of the imaging technique itself. The first of these improvements consists in the development of advanced schemes for grating-based tomography. These schemes can substantially reduce the dose delivered to the sample during a grating-based tomography scan, while preserving the image quality. Another major achievement of this thesis is the design, implementation and demonstration of a two-dimensional (2D) grating interferometer. This device uses gratings structured in two dimensions rather than line gratings. The 2D interferometer gives refraction angle and dark-field signals in multiple directions of the image plane and significantly improves the quality of the grating-based radiographies. The application range of the 2D interferometer is not restricted to X-ray imaging; the new device may also be particularly useful for high-precision optics characterization, as is shown by in-situ at-wavelength investigations of X-ray refractive lenses.
119

In-vivo-Flussdynamik des Hirnwassers im Spinalkanal - eine Phasenkontrast-Echtzeit-MRT-Studie / In vivo cerebrospinal fluid flow dynamics within the spinal canal: A real‐time phase‐contrast magnetic resonance imaging study

Konopka, Mareen Kathrin 10 October 2019 (has links)
No description available.
120

3D short fatigue crack investigation in beta titanium alloys using phase and diffraction contrast tomography / Caractérisation tridimensionnelle des fissures de fatigue courtes dans les alliages de titane métastable (béta) par tomographie en contraste de phase et de diffraction

Herbig, Michael 26 January 2011 (has links)
La tomographie en contraste de diffraction est une nouvelle technique non destructive d'imagerie synchrotron qui caractérise la microstructure et l'orientation des grains dans les matériaux polycristallins en trois dimensions (3D). En la combinant avec la tomographe par contraste de phase. Il est pour la première fois possible d'observer in situ la propagation 3D des fissures de fatigue courtes au sein d'un ensemble de grains entièrement caractérisé (orientation et forme). L'approche combinée, appelée « tomographie tri-dimensionnelle par rayons X des fissures courtes et de la microstructure »(T3DXFM), a été développée sur l’alliage de titane métastable "Beta21S". Une grande partie de ce travail porte sur le développement de la méthodologie T3DXFM. Dans le jeu de données combinées, chaque point de la surface de rupture 3D peut être associé à une structure de données multidimensionnelle contenant des variables décrivant l'orientation des grains, l'orientation locale de la surface de rupture ainsi que l'histoire de la propagation. La méthode utilise un maillage de surface composé de triangles qui décrit la fissure (en d'autres termes: la surface de rupture) dans l'état de propagation mesuré au dernier cycle de fatigue réalisé. Les orientations des grains, les différents fronts de la fissure, les vitesses de croissance locales ainsi que les joints de grains peuvent être visualisés en attribuant des couleurs à ce maillage. Des outils d'extraction des figures de pôle ont été créés et mis en œuvre. Un algorithme a été développé qui est capable de mesurer la vitesse de propagation locale 30 d'une fissure contenant des branchements. / X-Ray Diffraction Contrast Tomography (DCT) is a recently developed, non-destructive synchrotron imaging technique which characterizes microstructure and grain orientation in polycrystalline materials in three dimensions (3D). By combining it with propagation based phase contrast tomography (PCT) it is for the first lime possible to observe in situ the 3D propagation behavior of short fatigue cracks (SFCs) within a set of fully characterized grains (orientation and shape). The combined approach, termed 3D X-ray Tomography of short cracks and Microstructure (3DXTSM), has been developed on the metastable beta titanium alloy "Beta21S". A large part of this work deals with the development of the 3DXTSM methodology. In the combined dataset, each point on the 3D fracture surface can be associated with a multidimensional data structure containing variables describing the grain orientation, the local fracture surface normal and the propagation history. The method uses a surface mesh composed of triangles that describes the crack (in other words: the fracture surface) in the last propagation state measured. Grain orientations, crack fronts, local growth rates and grain boundaries can be visualized by assigning colors to this mesh. The data structure can be interrogated in a number of different ways. Tools for extracting pole figures and pole density distribution functions have been implemented. An algorithm was developed that is capable of measuring the 3D local growth rate of a crack containing branches. The accuracy of the grain boundaries as reconstructed with OCT was evaluated and the elastic constants of Beta21S were determined.

Page generated in 0.052 seconds