• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 72
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 73
  • 62
  • 27
  • 23
  • 22
  • 22
  • 21
  • 20
  • 19
  • 18
  • 17
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Projeto de atuadores piezelétricos flextensionais usando o método de otimização topológica. / Design of flextensional piezoelectric actuator using the topology optimization method.

Ronny Calixto Carbonari 24 March 2003 (has links)
Atuadores Piezelétricos Flextensionais consistem de uma estrutura flexível atuada por cerâmicas piezelétricas (ou “pilhas” de cerâmicas). A estrutura flexível conectada a piezocerâmica deve gerar deslocamentos e forças em diferentes pontos específicos do domínio, para uma direção especificada. Estes atuadores são usados em aplicações de mecânica de precisão, tal como, sistemas microeletromecânicos (MEMS), manipulador de células, interferometria laser, equipamentos de nanotecnologia, equipamentos de microcirurgias, nanoposicionadores, sonda de varredura microscópica, e etc. Porém, devido ao fato destes atuadores consistirem principalmente de um mecanismo flexível, seu projeto é complexo. A estrutura flexível comporta-se como um transformador mecânico pela amplificação para converter, direcionar e amplificar os pequenos deslocamentos gerados pela piezocerâmica (ordem de nanômetros). A estrutura flexível é projetada distribuindo-se flexibilidade e rigidez no domínio de projeto, o que pode ser obtido usando a otimização topológica. Portanto, o objetivo deste trabalho é implementar um método sistemático baseado no método de otimização topológica para projetar atuadores piezelétricos flextensionais. Essencialmente, o método de otimização topológica consiste em encontrar a distribuição ótima de material perfurando o domínio de projeto com infinitos microfuros. O material em cada ponto pode alterar de vazio a total presença de material, também assumindo material intermediário (ou compósito). A implementação do método de otimização topológica é baseado no modelo de material SIMP (Simple Isotropic Material with Penalization). O problema de otimização é posto como a maximização dos deslocamentos gerados (ou força de blocagem) em diferentes pontos e direções especificadas do domínio. Considerando o comportamento linear da piezocerâmica. Alterando a flexibilidade e a rigidez da estrutura flexível conectada a piezocerâmica obtém-se diferentes tipos de atuadores piezelétricos flextensionais, que podem ser projetados para determinadas aplicações. Para ilustrar o método, os exemplos mostrados são modelos bidimensionais (2D), uma vez que a maior parte das aplicações envolve dispositivos planos. Estes atuadores são fabricados usando corrosão química em chapas de cobre abaixo de 200 μm de espessura através do método de litografia. Técnica de corrosão química tem um baixo custo e permite-nos fabricar diversos protótipos para testes. Esta técnica pode ser facilmente utilizada no LNLS (Laboratório Nacional de Luz Síncrotron – Campinas). Análise experimental destes protótipos são procedidas para medição de deslocamentos usando uma Probe Station. Como trabalho futuro, estes protótipos serão construídos em escala de MEMS. / Flextensional Piezoelectric Actuators consist of a flexible structure actuated by piezoelectric ceramics (or a stack of piezoceramics). The flexible structure connected to the piezoceramic must generate displacements and forces in different specified points of the domain, according to a specific direction. These actuators are applied to precision mechanic applications such as microelectromechanical systems (MEMS), cell manipulators, laser interferometers, nanotechnology equipment, microsurgery equipment, nanopositioners, scanning probe microscopy, etc. However, due to the fact these actuators essentially consist of a compliant mechanism their design is complex. The compliant structure behaves as a mechanical transform by amplifying and changing the direction of small output displacements generated by piezoceramics (order of nanometer). The flexible structure is designed by distributing flexibility and stiffness in the design domain, which can be archieved by using topology optimization. Therefore, the objective of this work is to implement a systematic method based on topology optimization method to design flextensional piezoelectric actuators. Essentially, the topology optimization method consists of finding the optimal material distribution in a perforated design domain with infinite microvoids. The material in each point can change from void to full material, also assuming intermediate (or composite) material. The implemented topology optimization method is based on the SIMP (Simple Isotropic Material with Penalization) material model. The optimization problem is posed as maximization of output displacements (or grabbing forces) in different specified directions and points of the domain. A linear behavior of piezoceramic is considered. By changing the flexibility and stiffness of flexible structure connected to the piezoceramics different types of flextensional piezoelectric actuators can be designed for a desired application. To illustrate the method, examples presented herein are limited to two-dimensional (2D) models once in most part of applications of these actuators they are planar devices. These actuators are manufactured by using chemical corrosion on a 200 um thickness copper plate through lithography method. Chemical corrosion technique has a low cost and it allow us to manufacture several prototypes for testing. For this technique, facilities of the micromachining laboratory of National Sincroton Light Laboratory (LNLS - Campinas) are used. Experimental analysis of these prototypes are conducted by measuring displacements using a probe station. As a future work, these prototypes will be built in a MEMS scale.
22

Desenvolvimento de um modelo eletromecânico para diafragmas piezelétricos utilizados em sistemas de monitoramento de integridade estrutural / Development of an electromechanical model for piezoelectric diaphragms used in structural health monitoring systems

Freitas, Everaldo Silva de 23 July 2018 (has links)
Submitted by EVERALDO SILVA DE FREITAS null (everaldo.freitas@gmail.com) on 2018-09-12T02:59:57Z No. of bitstreams: 1 Tese_Doutorado_Everaldo_Freitas_FINAL_2018_ok.pdf: 1723520 bytes, checksum: dbd1b513bc9fa19ca8ac81016da5d0a9 (MD5) / Approved for entry into archive by Lucilene Cordeiro da Silva Messias null (lubiblio@bauru.unesp.br) on 2018-09-12T12:56:03Z (GMT) No. of bitstreams: 1 freitas_es_dr_bauru.pdf: 1679310 bytes, checksum: e2ca0b29e71f13ee7094695c96036f7a (MD5) / Made available in DSpace on 2018-09-12T12:56:03Z (GMT). No. of bitstreams: 1 freitas_es_dr_bauru.pdf: 1679310 bytes, checksum: e2ca0b29e71f13ee7094695c96036f7a (MD5) Previous issue date: 2018-07-23 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os diafragmas piezelétricos são componentes eletrônicos de baixo custo utilizados em diversas aplicações. Seu uso mais comum é como transdutor de áudio e, nesse tipo de aplicação, é mais comumente conhecido como buzzer. Nos últimos anos, a utilização desses componentes em estudos científicos avançados tem aumentado bastante, e uma das áreas que tem merecido destaque é a dos sistemas de Monitoramento de Integridade Estrutural – Structural Health Monitoring (SHM) – baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial por se basear no uso de transdutores piezelétricos pequenos e leves minimamente invasivos à estrutura monitorada. Portanto, tomando como base o crescente interesse por esses componentes, é proposto neste estudo um circuito eletromecânico equivalente básico que relacione as propriedades elétricas dos diafragmas piezelétricos com as propriedades mecânicas da estrutura monitorada por meio da impedância elétrica. Essa relação é baseada no efeito piezelétrico, que proporciona um acoplamento eletromecânico com a estrutura monitorada e, portanto, permite avaliar as condições mecânicas da estrutura a partir das propriedades elétricas do transdutor. A estrutura utilizada no estudo foi uma barra de alumínio com dimensões de 500 mm x 38,10 mm x 3,18 mm, tipicamente utilizada em laboratórios, e diafragmas com espessuras da ordem de uma fração de milímetro. Nessas condições, o modo de vibração principal pode ser considerado na direção longitudinal da estrutura para uma suposição unidimensional, de forma que o diafragma piezelétrico pode ser representado como um hexapolo com três portas, sendo uma porta elétrica e duas portas acústicas, solução esta comumente usada na literatura. As sensibilidades aos danos estruturais foram teoricamente analisadas em três diafragmas de diferentes tamanhos utilizando o circuito equivalente proposto. Essas sensibilidades foram comparadas com a de uma cerâmica piezelétrica convencional, que é o transdutor comumente utilizado no método da impedância E/M. Além disso, testes experimentais foram realizados em barras de alumínio para validação do circuito equivalente. Pode-se concluir que há correspondência entre os resultados teóricos e experimentais, pois as sensibilidades dos transdutores em ambas as análises foram próximas com poucas variações. / Piezoelectric diaphragms are inexpensive electronic components used in a variety of applications. Its most common use is as an audio transducer and, in this type of application, it is commonly known as "buzzer". In recent years, the use of these components in advanced scientific studies has increased significantly, and one of the areas that has received special mention is the Structural Health Monitoring (SHM) systems based on electromechanical impedance (EMI). This type of application has received special attention because it is based on the use of small and lightweight piezoelectric transducers minimally invasive to the monitored structure. Therefore, based on the growing interest in these components, a basic equivalent electromechanical circuit is proposed in this study that relates the electrical properties of the piezoelectric diaphragms to the mechanical properties of the monitored structure through the electrical impedance. This relationship is based on the piezoelectric effect, which provides an electromechanical coupling with the monitored structure and, therefore, allows to evaluate the mechanical conditions of the structure from the electrical properties of the transducer. The structure used in the study was an aluminum bar with dimensions of 500 mm x 38.10 mm x 3.18 mm, typically used in laboratories, and diaphragms with thicknesses of the order of a fraction of millimeter. Under these conditions, the main vibration mode can be considered in the longitudinal direction of the structure for a one-dimensional assumption, so that the piezoelectric diaphragm can be represented as a three-port hexapolo, one electric port and two acoustic ports, which is a solution commonly used in the literature. Sensitivities to structural damage were theoretically analyzed in three diaphragms of different sizes using the proposed equivalent circuit. These sensitivities were compared with that of a conventional piezoelectric ceramic, which is the transducer commonly used in the EMI method. In addition, experimental tests were performed on aluminum bars for equivalent circuit validation. It can be concluded that there is a correspondence between the theoretical and experimental results, because the sensitivities of the transducers in both analyzes were close with few variations. / FAPESP: 2015/02500-6
23

Controle de radiação sonora numa placa retangular através de atuadores piezelétricos discretos

Pergher, Rejane January 2003 (has links)
Neste trabalho, é estudado o controle da transmissão do som numa placa retangular e fina. Para tanto, é encontrada a resposta dinâmica da placa, excitada por forças harmônicas pontuais e piezomomentos, obtida usando uma base não-clássica e uma análise modal. A radiação sonora emitida pela vibração da placa é encontrada. A potência sonora radiada pode ser calculada aplicando controle ativo diretamente na estrutura, na forma de uma entrada vibratória, uma vez conhecida a resposta na superfície da placa, obtendo-se uma signicativa redução analitica. Os piezocerâmicos, modelados como quatro momentos pontuais, são unidos a superfície da placa como atuadores. A potência sonora transmitida antes e depois do controle é comparada, usando diferentes número de atuadores. Uma estratégia clássica de controle linear quadrático (LQR) e empregada no contexto de um procedimento de otimização da posição dos atuadores do sistema.
24

Sistema para aproveitamento de energia vibracional baseados em transdutores acústicos piezelétricos de baixo custo / Microgeneration based on a low-cost piezoelectric acoustic transducer

Cardoso, Adilson Jair 08 March 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This dissertation presents the development of a system for converting the mechanical energy from vibrations into electrical energy. The conversion is performed in a low-cost piezoelectric transducer, commonly known as buzzer. The main purpose of this system is to charge, or to extend the time between charges, of chargeable batteries up to 2V. In order to control the charging process, an integrated energy processor was also designed. Processor design is presented from its specification, followed by circuit topology definition, electric simulation, layout, extraction of circuit from layout and a final simulation including layout effects. The main contribution of the investigation is to show how much energy could be obtained from vibrations with a low-cost transducer, comparing its performance to full custom generators. The final system implementation is very simple, composed by a generator (a buzzer with a steel ball glued onto its center) and an integrated circuit that controls the charge delivered to the battery, sensing the voltage across its terminals. An efficiency of 55% is expected, being comparable to results published by other researchers. / Esta dissertação apresenta o desenvolvimento de um sistema para converter energia mecânica de vibrações em energia elétrica. A conversão é realizada através de um transdutor de baixo custo comumente chamado de buzzer. O principal objetivo deste sistema é carregar ou estender o tempo entre cargas de baterias recarregáveis de até 2 V. Para o controle do processo de carga, um processador de energia integrado também foi desenvolvido. O projeto do processador de energia é apresentado segundo especificações como definição de topologia, simulação elétrica, layout, extração elétrica do circuito através do layout e a simulação final incluindo os efeitos do layout. A principal contribuição desta dissertação é mostrar como muita energia poderia ser obtida de vibrações com um transdutor de baixo custo, comparando sua performance a outros microgeradores. O sistema final implementado é muito simples, composto por um microgerador (buzzer com uma esfera de aço colada no centro) e um circuito integrado que controla a carga da bateria, através da monitoração da tensão da mesma. Uma eficiência de 55% é esperada, sendo comparável com os resultados obtidos por outros pesquisadores.
25

Controle de radiação sonora numa placa retangular através de atuadores piezelétricos discretos

Pergher, Rejane January 2003 (has links)
Neste trabalho, é estudado o controle da transmissão do som numa placa retangular e fina. Para tanto, é encontrada a resposta dinâmica da placa, excitada por forças harmônicas pontuais e piezomomentos, obtida usando uma base não-clássica e uma análise modal. A radiação sonora emitida pela vibração da placa é encontrada. A potência sonora radiada pode ser calculada aplicando controle ativo diretamente na estrutura, na forma de uma entrada vibratória, uma vez conhecida a resposta na superfície da placa, obtendo-se uma signicativa redução analitica. Os piezocerâmicos, modelados como quatro momentos pontuais, são unidos a superfície da placa como atuadores. A potência sonora transmitida antes e depois do controle é comparada, usando diferentes número de atuadores. Uma estratégia clássica de controle linear quadrático (LQR) e empregada no contexto de um procedimento de otimização da posição dos atuadores do sistema.
26

Análise experimental de diafragmas piezelétricos comerciais para detecção de dano estrutural baseada na impedância eletromecânica / Experimental analysis of commercial piezoelectric diaphragms for structural damage detection based on the electromechanical impedance

Freitas, Everaldo Silva de [UNESP] 30 May 2016 (has links)
Submitted by EVERALDO SILVA DE FREITAS null (everaldo.freitas@gmail.com) on 2016-07-03T18:42:32Z No. of bitstreams: 1 Dissertação_Mestrado_Everaldo_Freitas_2016_final.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-07T16:33:04Z (GMT) No. of bitstreams: 1 freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Made available in DSpace on 2016-07-07T16:33:04Z (GMT). No. of bitstreams: 1 freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) Previous issue date: 2016-05-30 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação de mestrado apresenta uma análise experimental da viabilidade do uso dos diafragmas piezelétricos comerciais de baixo custo (comumente conhecidos como buzzers) em sistemas de monitoramento de integridade estrutural (SHM – Structural Health Monitoring) baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial nas últimas décadas por se basear no uso de transdutores piezelétricos pequenos e leves que operam simultaneamente como sensores e atuadores. Foram realizados vários testes em barras de alumínio utilizando diafragmas de diversos tamanhos; as assinaturas de impedância elétrica e os índices de dano foram comparados com os obtidos usando uma cerâmica convencional de PZT (Pb-lead Zirconate Titanate – titanato zirconato de chumbo), que é o transdutor mais comumente utilizado nessa aplicação. Os danos estruturais foram simulados utilizando-se massas metálicas (porcas de parafuso), as quais foram fixadas nas barras com cola a base de cianoacrilato. Quatro tipos de experimentos foram realizados para fins de comparação: estimação da sensibilidade dos transdutores utilizando método da quebra do grafite (PLB – Pencil Lead Break – quebra do grafite); comparação dos índices de dano RMSD (root mean square deviation – desvio da raiz média quadrática) e CCDM (correlation coefficient deviation metric – métrica do desvio do coeficiente de correlação), calculados a partir das assinaturas de impedância; avaliação dos efeitos da temperatura; e a avaliação da reprodutibilidade dos resultados a longo prazo. Os resultados indicaram que a cerâmica convencional de PZT e um diafragma de tamanho semelhante apresentam características bem próximas em relação à reprodutibilidade dos resultados, sensibilidade ao dano e aos efeitos de temperatura, o que leva a conclusão de que os diafragmas são viáveis para sistemas de SHM baseados na impedância E/M. / This dissertation presents an experimental analysis of the viability of low-cost commercial piezoelectric diaphragms (commonly known as buzzers) in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. This application has received special attention in recent decades because it is based on the use of small, lightweight piezoelectric transducers operating as both sensors and actuators. Several tests were carried out on aluminum bars using diaphragms of different sizes; the electrical impedance signatures and damage indices were compared with those obtained using a conventional PZT (Pb-Lead Zirconate Titanate) ceramic, which is the most commonly employed transducer in this application. Structural damage was simulated using metallic bolts (steel nut), which were fixed in the bars using cyanoacrylate glue. Four types of experiments were carried out for comparison between the two transducers: sensitivity estimation using the pencil lead break (PLB) method, analysis of the feasibility to detect structural damage using conventional impedance signatures and damage indices, analysis of temperature effects, and determination of the long-term reproducibility of the results. The results indicated that conventional PZT ceramics and diaphragms with similar size exhibit very close characteristics in relation to reproducibility, sensitivity to damage and temperature effects, which leads to the conclusion that the piezoelectric diaphragms are feasible in SHM systems based on the EMI method. / FAPESP: 2015/02500-6
27

Desempenho dos métodos de instalação de transdutores piezelétricos em sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânica / Performance of installation methods in piezoelectrics transducers in structural integrity monitoring systems based on electromechanical impedance

Silveira, Ricardo Zanni Mendes da [UNESP] 26 May 2017 (has links)
Submitted by RICARDO ZANNI MENDES DA SILVEIRA null (ricazanni@gmail.com) on 2017-06-07T16:11:41Z No. of bitstreams: 1 Dissertação_Mestrado_Eng_Eletrica_Ricardo_Zanni_2017.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-07T16:26:32Z (GMT) No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Made available in DSpace on 2017-06-07T16:26:32Z (GMT). No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) Previous issue date: 2017-05-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Transdutores piezelétricos são amplamente utilizados em muitos métodos não destrutivos para a detecção de danos estruturais em aplicações de monitoramento de integridade estrutural ou SHM (Structural Health Monitoring). Dentre os vários métodos não destrutivos, a técnica da impedância eletromecânica (E/M) é conhecida por utilizar cerâmicas piezelétricas pequenas e finas que desempenham simultaneamente as funções de atuador e sensor. O método convencional de instalação dessas cerâmicas piezelétricas na estrutura é utilizando um adesivo de alta rigidez como cola a base de epóxi ou cianoacrilato. No entanto, alguns estudos propõem métodos alternativos de instalação do transdutor, visando a sua reutilização ou que permitam o monitoramento em condições adversas sob as quais a instalação direta do sensor não seria possível. Assim, esta dissertação de mestrado apresenta uma análise experimental comparativa entre os principais métodos de acoplamento entre o transdutor piezelétrico e a estrutura monitorada em sistemas de SHM baseados na técnica da impedância eletromecânica (E/M). Os acoplamentos dos transdutores piezelétricos foram realizados pelos métodos da instalação direta, também conhecida como instalação convencional, por acoplamento magnético e lâminas de alumínio. O transdutor utilizado para os métodos de acoplamento foi o diafragma piezelétrico, comumente conhecido como buzzer. Testes com os três métodos de instalação foram realizados em estruturas de alumínio e o dano estrutural foi induzido por meio de adição de massa metálica (porca de aço), fixada diretamente na estrutura com cola a base de cianoacrilato. A análise comparativa entre os métodos de instalação foi realizada utilizando índices de danos obtidos das assinaturas de impedância elétrica dos diafragmas piezelétricos, além da função de resposta em frequência (FRF) e da densidade espectral de potência obtida pelo método da quebra do grafite. Os resultados experimentais apontam características importantes para os métodos de instalação, os quais têm influência significativa sobre a resposta em frequência e sensibilidade para a detecção de danos estruturais. / Piezoelectric transducers are widely used in many non-destructive methods for detecting structural damage in Structural Health Monitoring (SHM) applications. Among the various techniques for detecting structural damage, the electromechanical impedance (EMI) technique is known to use fine and small piezoelectric ceramics that simultaneously perform the actuator and sensor functions. The conventional method of installing these piezoelectric ceramics in the structure is by using a high stiffness adhesive such as epoxy or cyanoacrylate based glue. However, some studies propose alternative methods of installing the transducer for reuse or to allow monitoring under adverse conditions under which direct sensor installation would not be possible. Thus, this master's thesis presents a comparative experimental analysis between the main coupling methods between the piezoelectric transducer and the monitored structure in SHM systems based on the electromechanical impedance technique. The piezoelectric transducer couplings were made by direct installation methods, also known as conventional installation, by magnetic coupling and aluminum foils. The transducer used for the coupling methods was the piezoelectric diaphragm, commonly known as buzzer. Tests with these methods were carried out on aluminum structures and the structural damage was induced using metallic masses (steel nuts), fixed directly to the structure with cyanoacrylate-based glue. The comparison of the results analysis between the coupling methods was performed using the indices of damages obtained from electrical impedance signatures of the piezoelectric diaphragm, the frequency response function (FRF) and the power spectral density (PSD) obtained by pencil lead break (PLB) test. The experimental results indicate important characteristics for each installation method and that the mounting method has a significant influence on the frequency response and sensitivity for the detection of structural damage. / FAPESP: 2015/02500-6
28

Detecção de dano estrutural baseada na técnica da impedância eletromecânica em ambientes ruidosos / Detection of structural damage based on the electromechanical impedance technique in noisy environments

Campeiro, Leandro Melo 18 May 2018 (has links)
Submitted by Leandro Melo Campeiro (leandro_campeiro@yahoo.com.br) on 2018-05-24T19:40:02Z No. of bitstreams: 1 Dissertação de Leandro Melo Campeiro.pdf: 3027230 bytes, checksum: 32f869e7ce55b33b1e9c46a166e8cf5f (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-05-25T18:21:44Z (GMT) No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) / Made available in DSpace on 2018-05-25T18:21:44Z (GMT). No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) Previous issue date: 2018-05-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A técnica da impedância eletromecânica (E/M) tem sido amplamente estudada nas últimas décadas como um método não destrutivo para detectar danos estruturais em aplicações de monitoramento de integridade estrutural (SHM – structural health monitoring) usando transdutores piezelétricos de baixo custo. Esses transdutores operam simultaneamente como sensor e atuador e são fixados à estrutura monitorada utilizando um adesivo a base de cianoacrilato. Embora muitos estudos tenham relatado a eficácia desse método de detecção, inúmeros problemas práticos têm sido reportados, como os efeitos de ruído e vibração, que precisam ser considerados para permitir o uso eficaz desse método em aplicações reais. Portanto, esta dissertação de mestrado apresenta uma análise experimental dos efeitos do ruído e das vibrações na detecção de danos estruturais em sistemas de SHM baseados na técnica da impedância eletromecânica. Os experimentos foram realizados em uma barra de alumínio usando dois diafragmas piezelétricos, sendo que um deles foi usado para obter as assinaturas de impedância elétrica e o outro foi usado como atuador para introduzir ruído e vibração controlada. Para a simulação de dano foi utilizada uma pequena massa metálica fixada na estrutura com uso de adesivo a base de cianoacrilato. Os efeitos do ruído e da vibração sobre as assinaturas de impedância foram avaliados por meio do cálculo da função de coerência e de índices básicos de dano. Os resultados indicam que a vibração e o ruído afetam significativamente o limiar do menor dano detectável, o qual pode ser compensado pelo aumento do sinal de excitação do transdutor piezelétrico utilizado para a obtenção das assinaturas de impedância elétrica. / The electromechanical impedance (EMI) technique has been extensively studied in recent decades as a non-destructive method for detecting structural damage in structural health monitoring (SHM) applications using low-cost piezoelectric transducers. These transducers operate simultaneously as actuator and sensor and they are fixed to the structure using cyanoacrylate-based glue. Although many studies have reported the effectiveness of this detection method, a lot of practical problems shown up, such as the noise effects and vibration, that need to be addressed to enable this method’s effective use in real applications. Therefore, this master's thesis presents an experimental analysis of noise and vibration effects on the structural damage detection in impedance-based SHM systems. The experiments were performed on an aluminum bar using two piezoelectric diaphragms, where one was used to measure the electrical impedance signatures and the other was used as an actuator to introduce noise and controlled vibration. To simulate damage, a small metal mass was fixed to the structure using cyanoacrylate glue. The effects of noise and vibration on the impedance signatures were evaluated by computing the coherence function and basic damage indices. The results indicate that vibration and noise significantly affect the threshold of the lowest detectable damage, which can be compensated by increasing the excitation signal of the piezoelectric transducer that measure the electrical impedance signature.
29

Análise de materiais piezelétricos compósitos para aplicações em transdutores de ultra-som. / Analysis of piezoelectric composite materials for ultrasonic transducers applications.

Marco Aurélio Brizzotti Andrade 14 March 2006 (has links)
O objetivo deste trabalho é analisar materiais piezelétricos compósitos com conectividade 1-3 e 2-2 para aplicações em transdutores de ultra-som na faixa de MHz utilizando modelos matemáticos e verificações experimentais. O estudo de um material piezelétrico compósito pode ser feito através de seus três principais tipos de modos de vibração: modo planar, modo de espessura e modo lateral. Neste trabalho, é utilizado o método dos elementos finitos para modelar os modos planares, de espessura e laterais de um compósito, e modelos analíticos para modelar o modo de espessura e o modo lateral. A modelagem do modo de espessura de um transdutor de ultra-som é feita a partir de um modelo analítico unidimensional. A modelagem unidimensional de um transdutor de ultra-som é feita através do cálculo das propriedades efetivas do material piezelétrico compósito. Essas propriedades são utilizadas no modelo da matriz distribuída para prever a impedância elétrica de um compósito e a resposta impulsiva de um transdutor de ultra-som. Com o objetivo de validar os modelos, foram construídos um material piezelétrico compósito com conectividade 1-3 e outro com conectividade 2-2 através da técnica “dice-and-fill”, utilizando cerâmica de PZT-5A e resina epóxi. O compósito com conectividade 1-3 foi utilizado na construção de um transdutor de ultra-som. Os resultados teóricos da impedância elétrica e da resposta impulsiva são comparados com os obtidos experimentalmente. A impedância elétrica experimental é obtida através de um analisador de impedâncias, enquanto que a resposta impulsiva experimental do eco do transdutor é medida acoplando o protótipo do transdutor a um tarugo de acrílico. Devido à periodicidade do compósito foi feito um estudo teórico da propagação de ondas mecânicas em meios periódicos, mostrando que existem determinadas faixas de freqüências que não se propagam no material. Foi verificado que esta periodicidade é responsável pela diminuição das amplitudes dos modos radiais de um material piezelétrico compósito quando comparados com os modos radiais de um disco de cerâmica piezelétrica. Também foram feitos ensaios em tanque de imersão para determinar as propriedades mecânicas de amostras de epóxi e amostras de tungstênio e epóxi em função da fração de volume de tungstênio na amostra. / The objective of this work is to analyze piezoelectric composite materials with 1-3 and 2-2 connectivity for applications in ultrasonic transducers in the megahertz frequency range. The analysis is done through mathematical models and experimental validation. The analysis of piezoelectric composite materials can be done through the study of its three main vibrational modes: planar mode, thickness mode, and the lateral mode. In this work, it is used the Finite Element Method to model the planar, thickness and the lateral modes of the composite, and it is used analytical models to model the thickness and the lateral modes. The modeling of the thickness mode of an ultrasonic transducer is obtained through an unidimensional analytical model. The unidimensional modeling of the transducer is done by calculating the effective properties of the piezoelectric composite material. The effective properties are used in a distributed matrix model to calculate the electrical impedance of the composite and the impulse response of an ultrasonic transducer. To validate the models, a 1-3 and a 2-2 piezoelectric composite were built using the “dice-and-fill” technique. These composite were constructed using a piezoelectric ceramic of PZT-5A and epoxy. The piezoelectric composite with 1-3 connectivity was used in the fabrication of an ultrasonic transducer. The theoretical results of the electrical impedance and the impulse response are compared with the experimental results. The experimental electrical impedance is measured by using an impedance analyzer, and the experimental impulse response is measured by coupling the ultrasonic transducer prototype to an acrylic block. Due to the periodicity of the composite, it was analyzed the behaviour of mechanical waves in periodic media, showing that there are frequency ranges that the waves cannot propagate. It was verified that the periodicity is responsible for the suppression of the radial modes in a piezoelectric composite when compared with the radial modes of a disk of piezoelectric ceramic. It is also conducted measurements in a water filled tank to determine the mechanical properties of samples of epoxy, and Tungsten/epoxy composites as a function of the volume fraction of Tungsten.
30

Projeto de materiais piezocompósitos baseados no conceito de gradação funcional utilizando o método de otimização topológica. / Design of piezocomposite materials based on functionally graded concept by means of topology optimization method.

Sandro Luis Vatanabe 09 November 2012 (has links)
Um material piezocompósito é resultante da combinação de um material piezelétrico com outros materiais não-piezelétricos, oferecendo vantagens substanciais em relação aos materiais piezelétricos convencionais. Diferentes propriedades efetivas podem ser obtidas alterando-se a fração de volume dos constituintes ou a própria topologia da célula unitária do piezocompósito. Materiais com Gradação Funcional (MGF) são materiais compósitos avançados, projetados de tal forma que sua composição varie gradualmente numa direção espacial. A vantagem do conceito MGF é não apresentar interface convencional entre os materiais da inclusão e da matriz, reduzindo assim um problema comum em materiais compósitos laminados, como por exemplo, o surgimento de concentração de tensões mecânicas. O Método de Otimização Topológica (MOT) é uma técnica computacional utilizada para se determinar a distribuição de materiais em uma estrutura ou material de forma sistemática, a fim de se extremizar uma determinada função objetivo. Assim, esse trabalho propõe uma metodologia sistemática e genérica para o projeto de materiais piezocompósitos com gradação funcional (MPGF) utilizando o MOT, tanto para aplicações quasi-estáticas, quanto para aplicações dinâmicas. Dessa forma, divide-se o projeto de materiais piezocompósitos em três grupos. O primeiro grupo consiste em um método de projeto de materiais baseado na combinação do método de homogeneização com o MOT para o projeto de MPGF para aplicações quasi-estáticas, onde o objetivo é projetar materiais piezocompósitos que, de modo geral, maximizem a conversão de energia mecânica em elétrica. A aplicação utilizada como exemplo neste trabalho são materiais empregados em dispositivos de coleta de energia. O segundo grupo visa aplicações dinâmicas de materiais piezocompósitos fonônicos, onde a propriedade de interesse é a possibilidade de se ter faixas de frequência, mais conhecidas por band gaps, nas quais ondas elásticas não se propagam. Assim, neste estudo visa-se o projeto de MPGF fonônicos com largura e posição de band gaps prescritos, empregando estruturas unidimensionais, e a maximização de diversos band gaps, empregando estruturas bidimensionais. O terceiro grupo explora o conceito de gradação geométrica, baseado em repetições de padrão ao longo do domínio de projeto, porém cada repetição tem um ou mais comprimentos modificados, de forma gradual. Dessa forma, suas propriedades alteram-se progressivamente ao longo da estrutura, embora a distribuição de materiais seja discreta, contornando assim possíveis dificuldades de manufatura. Esta abordagem é empregada visando à aplicação na coleta de energia, onde se procura maximizar a potência elétrica gerada em um resistor acoplado aos eletrodos, através da obtenção da topologia otimizada de estruturas piezocompósitas. Exemplos numéricos são apresentados de forma a ilustrar as metodologias de projeto propostas, bem como, analisar a influência dos parâmetros de otimização nos resultados. / Piezocomposite materials result from the combination of a piezoelectric material with other non-piezoelectric materials, offering advantages over conventional piezoelectric materials. Different effective properties can be obtained by changing the volume fraction of constituent materials, the shape of inclusions, or even the topology of the unit cell. Functionally Graded Materials (FGM) are composite materials, which are designed so that its composition varies gradually in space. One of the advantages of FGMs is that there is no conventional interface between the constituent materials, which reduces, for instance, microscopic stress concentration problems in composite materials. Topology Optimization Method (TOM) is a computational technique used to determine the material distribution of a structure or material in a systematic way, in order to maximize a determined objective function. Thus, this study proposes a generic and systematic methodology to design Functionally Graded Piezocomposites Materials (FGPM) using TOM, for quasi-static and dynamic applications. The study is divided into three groups. The first group combines the homogenization method with TOM in order to design FGPM for quasi-static applications, where the goal is to maximize the conversion of mechanical energy into electrical energy. The application used as an example in this study focuses materials used in energy harvesting devices. The second group focuses on dynamic applications of phononic piezocomposite materials, where the property of interest is the possibility of having frequency band gaps, in which elastic waves do not propagate. This study aims to design phononic FGPM with prescribed band gap width using one-dimensional model, and to design phononic FGPM with maximized band gaps using two-dimensional model. The third group investigates the pattern gradation concept, based on pattern repetitions over the design domain, but each pattern has one or more dimensions gradually modified. Thus, properties change gradually along the structure, although the material distribution keeps in the discrete form, thereby circumventing potential manufacturing difficulties. The objective function consists of maximizing the electric power generated in a load resistor. A projection scheme is employed to compute the element densities from design variables and control the length scale of the material density. Numerical examples are presented and discussed using the proposed methods.

Page generated in 0.0594 seconds