• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2273
  • 60
  • 60
  • 60
  • 54
  • 40
  • 39
  • 9
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 2354
  • 1144
  • 638
  • 542
  • 473
  • 425
  • 340
  • 240
  • 232
  • 212
  • 205
  • 174
  • 167
  • 166
  • 159
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Plano específico de zoneamento de emissões para o Aeroporto Internacional de Viracopos

Luciana Lins de Mello 07 August 2015 (has links)
O objetivo dessa pesquisa é propor a aplicação de um plano específico de zoneamento de emissões, com base no impacto dos poluentes atmosféricos gerados no sítio aeroportuário. Como estudo de caso, foi escolhido o Aeroporto Internacional de Viracopos por tratar-se de aeroporto que apresenta forte crescimento e encontra-se em sítio ainda parcialmente preservado quanto à ocupação urbana. De acordo com o Relatório 4 do IPCC (Painel Intergovernamental sobre Mudanças Climáticas, 2007), o setor da aviação contribui com 3% do volume mundial de emissões e espera-se um crescimento anual de 4%. A tarefa de dissociar o crescimento do transporte aéreo de seus impactos ambientais, em curto prazo, é improvável. De acordo com a Organização Mundial de Saúde, durante o ano de 2012, cerca de 3,7 milhões de pessoas morreram por estarem expostas à poluição do ar. Este estudo demonstra, através da revisão bibliográfica, a diminuição do ritmo dos avanços tecnológicos e a falta de regulamentação do setor aeronáutico nacional e internacional quanto às emissões de gases e seus efeitos sobre a saúde da população que vive perto de principais aeroportos internacionais. Para desenvolver o estudo foi necessário agregar fontes poluidoras internas ao sítio aeroportuário e projetar o crescimento da demanda do aeroporto. Outra parte fundamental no estudo são os dados sobre a meteorologia específica da cidade de Campinas, São Paulo, e sua influência na dispersão dos poluentes. Na simulação de quantificação de poluentes foi utilizado o programa EDMS 5.1.4.1 (Emissions and Dispersion Modeling System), desenvolvido pela FAA (Federal Aviation Administration), que utiliza o AERMOD para o cálculo da dispersão. O AERMOD é um programa computacional que modela a dispersão de gases. Os resultados apontaram que o clima tropical, úmido e com fortes ventos, favorece a dispersão e disseminação de poluentes. Para a maioria dos poluentes testados, a ampliação do Aeroporto Internacional de Viracopos não trará riscos à população do entorno, no entanto, haverá um grande aumento de óxidos de nitrogênio (NOx). O NOx refere-se à soma das concentrações de monóxido de nitrogênio (NO) e dióxido de nitrogênio (NO2) e é associado a graves problemas de saúde, como a incidência da síndrome da morte súbita em recém-nascidos. A regulamentação territorial, através do planejamento urbano, é proposta neste trabalho como forma de mitigação da ação poluidora do NOx no entorno dos aeroportos.
372

Projeto, construção e ensaio de uma câmara de combustão de microturbina operando com etanol

Ramón Eduardo Pereira Silva 08 July 2015 (has links)
Neste trabalho foram desenvolvidos os projetos de uma câmara de combustão e de um atomizador do tipo pressure-swirl que permitiram a operação de uma microturbina a gás, utilizando etanol como combustível. O combustor e o injetor foram projetados para as características físico-químicas do etanol anidro. A influência da presença de água no combustível foi ser analisada nos ensaios. Foram realizados ensaios de desempenho e emissões de gases na microturbina. A determinação do Diâmetro Médio de Sauter (SMD) e do ângulo de abertura do do spray também foi realizada. Na análise dos resultados investigou-se o comportamento das relações ar/combustível, a emissão de poluentes e sua correlação com atomização do combustível e com a eficiência de combustão. A operação da microturbina ocorreu de maneira estável, validando tanto o projeto do combustor quanto o do atomizador. A razão de equivalência aumentou com o aumento da rotação do eixo. A pressão de injeção aumentou com o incremento de vazão provocando a diminuição do SMD. Fato esse que promoveu decréscimo nas emissões de monóxido de carbono (CO) e óxidos de nitrogênio (NOx) demonstrando melhoria na eficiência de combustão.
373

Redução dos impactos ambientais em recursos hídricos utilizando multimetodologia

Leonardo Rodrigues Caixeta 19 October 2015 (has links)
A contaminação dos recursos hídricos naturais é um dos principais problemas da sociedade moderna. A qualidade destes recursos naturais é alterada constantemente, devido ao crescimento populacional e fatores de poluição doméstica e industrial. Os cuidados na utilização consciente e minimização dos desperdícios da água em processos produtivos vêm recebendo especial atenção, pois este recurso é muito importante para as indústrias. Este trabalho tem como objetivo principal determinar um conjunto de ações para reduzir os impactos ambientais que ocorrem nos recursos hídricos devido às atividades e processos da indústria, utilizando uma Multimetodologia de Pesquisa Operacional. A situação problemática foi mais bem compreendida a partir da aplicação da Metodologia Strategic Choice Approach (SCA). Uma proposta deste trabalho é utilizar o Método Multicritério de Apoio a Decisão, Analytic Hierarchy Process (AHP) com Rating no Modo de Comparação do SCA. Este trabalho traz uma abordagem multimetodológica com uma interação entre as fases de estruturação do problema, seleção das alternativas viáveis e tratamento das incertezas. Os resultados mostram que para a redução dos impactos ambientais em recursos hídricos é necessário a participação das empresas privadas e universidades, aplicando-se leis ambientais federais, estaduais e municipais para garantir a preservação dos recursos hídricos, sendo necessária a utilização de técnicas oxidativas avançadas para tratamento dos compostos poluidores com descartes dos efluentes acima da captação de água realizada pela indústria no corpo hídrico receptor.
374

Amostradores de vapores do solo (avs) |b desenvolvimento de uma técnica para a detecção de águas subterraneas contaminadas por solventes orgânicos voláteis. Estudo de caso de Porto Feliz - São Paulo

Hirata, Ricardo Cesar Aoki 24 October 1990 (has links)
A Amostragem de Vapores do Solo (AVS) é uma técnica introduzida recentemente usada para a detecção, de forma indireta, da contaminação das águas subterrâneas por solventes orgânicos-voláteis, incluindo entre estes, os chamados DNAPL.O rápido desenvolvimento desta técnica foi motivado pela dificuldade e elevados custos que estão envolvidos os métodos tradicionais na avaliação do impacto de um acidente com substâncias organo-sintéticas. Tais métodos implicam na perfuração de numerosos poços de monitoração associados a um programa de coleta de água e análise. Dadas as características destes produtos químicos de não apresentarem contrastes elétricos e possuírem baixa solubilidade em água, métodos geofísicos comumente usados (eletroresistividade e eletromagnéticos) não têm se mostrado eficazes. A técnica AVS envolve a extração de uma pequena quantidade de gases succionado do solo a pouca profundidade e sua análise em campo ou laboratório, identificando os compostos presentes e correlacionando as composições dos vapores e das águas subterrâneas. O principio de detecção relaciona-se com o estabelecimento de um gradiente de concentração química na zona não-saturada, resultando um fluxo difusivo ascendente do contaminante nas áreas onde as águas subterrâneas se acham poluídas. O presente trabalho desenvolve a técnica AVS inovando na forma de aprisionamento de vapores quando se sugere o uso de colunas adsorventes duplas de carvão ativado, e adapta procedimentos de laboratório com uso de cromatografia gasosa para análise de colunas e identificação dos poluentes. Esta dissertação apresenta os resultados do uso da técnica AVS desenvolvida neste estudo, quando da aplicação pioneira no Brasil, acidente ambiental ocorrido no em Porto Feliz - (SP), onde o vazamento de um tanque de solventes orgânicos causou a contaminação de expressiva porção do aquífero. O AVS permitiu avaliar com sucesso a extensão do acidente de poluição no aquífero e em subsuperfície e o formato da pluma contaminante. O mapeamento com AVS definiu três zonas com diferentes concentrações de vapores: altas, médias e baixas e mostrou que a pluma está se deslocando no sentido SE para NW atingindo, no momento, uma área de 113.000 m². A coleta de vapores do solo a diferentes profundidades possibilitou o estabelecimento das taxas de volatilização, quantificando o fluxo vertical de tetracloreto de carbono em 1,0 x 1\'0 POT.-5\' \'+ OU -\' 6,9 x 1\'0 POT.-7\'µ/m²/s e clorofórmio em 6,4 x 1\'0 POT. -5\' \'+ OU -\' 1,7 x 1\'0 POT. -5 µ/m²/s. Os resultados das amostras de água subterrânea e vapores do solo permitiram estabelecer correlações bastante expressivas de 0,9 e 0,8 para o clorofórmio e tetracloreto de carbono. Com intuito de medir o tempo de trânsito e volatilização dos compostos halogenados de interesse em meio não saturado, foram preparados experimentos envolvendo colunas de areia em laboratório. Os testes permitiram avaliar as perdas por volatilização do clorofórmio e tetracloreto de carbono numa razão de 20 e 30%, após 30 horas de experimento. Esta dissertação analisa também, de forma crítica, trabalhos publicados por outros pesquisadores, permitindo avaliar a técnica aqui proposta comparativamente a outras. estabelecer alcances e restrições do método, dando ênfase na influência do meio e dos compostos no sucesso do uso do AVS, tema ainda pouco explorado por pesquisadores desta técnica. Este estudo sugere ainda uma classificação em 6 grupos do método AVS, segundo sua configuração e forma de aprisionamento e análise dos contaminantes. / Soil-gas sampling is a recently introduced technique for the indirect detection of groundwater contamination by volatile organics, including dense non-aqueous phase Iiquids (DNAPLs), such as those involved in the Porto Feliz accident. The rapid development of this technique was prompted by the difficulties and high costs that are involved in the evaluation of the impact of an accident with synthetic organic substances using traditional methods. The traditional approach involves the drilling of many monitoring wells to be used subsequently in a groundwater sampling and laboratory analysis program. In the Porto Feliz case, the chemical compounds involved showed negligible electrical contrast and low solubility in water, making commonly used geophysical methods, such as electrical resistivity and electromagnetic induction logging, inapplicable. The soil gas sampling technique involves the extraction of a small amount of soil gas from a shallow depth with subsequent analysis in the field or laboratory, identiying the compounds present and correlating the vapor composition with the composition of the underlying groundwater. The principle behind the technique is related to the establishment of a chemical concentration gradient in the unsaturated zone which causes an upward diffusive flux of contaminants in areas where the underlying groundwater is contaminated with volatile organics. The present research developed a soil gas sampling technique which is innovative in both the manner gases are captured, through the use of a double activated carbon column apparatus, and in the laboratory procedures used to analyze the columns and identify the pollutants with gas chromatography. The dissertation presents the results of the application of the soil gas sampling technique developed in this study to the environmental accident which occured in Porto Feliz when a large solvent tank leaked and contaminated a significant portion of the underlying aquifer. It is the first application of the soil gas sampling technique in Brasil. The technique allowed the successful evaluation of the extent of aquifer contamination and the shape of the groundwater plume. Plume mapping using soil gas concentrations defined three zones with different vapor concentration levels: high, medium and low. It also showed the plume moving in a SE to NW direction, contaminating 113,000 m² at the present time. The extraction of vapors at different depths allowed the calculation of soil gas emission flux rates of 1,0 x 1\'0 POT. -5\' \'+ OU - \' a 6,9 x 1\'0 POT. -7\' and 6,4 x 1\'0 POT. -5\' \'+ OU -\'1,7 x 1\'0 POT. -5\' µg/m²/s for chloroform and carbon tetrachloride respectively. The results of groundwater and vapor sampling showed excellent correlation coefficients of 0,9 and 0,8 for chloroform and carbon tetrachloride respectively. With the idea of measuring the travel time and volatilization of halogenated organics of interest in the unsaturated zone, experiments involving sand columns were prepared in the laboratory. The tests allowed the evaluation of volatilization losses of chloroform and carbon tetrachloride on the order of 20 and 30% hours of flow. The dissertation constructively analyzes studies published by other researchers, allowing a comparative evaluation of their techniques with the technique developed in this study. A review of more than 100 published documents on the subject allowed the establishment of restrictive limits on the method, highlighting the influence of the medium and the physico-chemical properties of the chemical compounds on the success of the soil gas sampling technique. The literature review also resulted in classiffing soil gas sampling into 6 groups according to the physical method used, the manner of gas capturing and the method of analyzing the gases.
375

Avaliação da poluição atmosférica de elementos químicos pela análise de líquen epifítico no campus da Cidade Universitária de São Paulo / Assessment of atmospheric pollution of chemical elements by epiphytic lichen analysis at the campus of the São Paulo University

Rocha, Rosiana Rocho 05 November 2015 (has links)
A poluição atmosférica tem sido tema frequente de pesquisas, devido aos efeitos que podem afetar a saúde dos seres vivos, o meio ambiente e clima. A fim de identificar as fontes de emissão dos poluentes e de seus efeitos, o método de biomonitoramento vem sendo estudado devido ao seu baixo custo e a possibilidade de amostragem em amplas áreas geográficas. Neste trabalho, para biomonitoramento passivo da poluição atmosférica no campus da Cidade Universitária Armando Salles de Oliveira (CUASO) da Universidade de São Paulo, foi utilizado líquen epifítico da espécie Canoparmelia texana. Os liquens coletados em troncos de árvores de diferentes pontos da CUASO foram limpos, secos por liofilização e moídos para análise pelos métodos de espectrometria de fluorescência de raios X (XRFS) e análise por ativação neutrônica (NAA). Na XRFS as amostras preparadas na forma de pastilhas foram analisadas para determinação de As, Br, Ca, Cl, Cr, Cu, Fe, K, Mn, Rb, S, Sr e Zn. Na NAA, alíquotas de amostras de liquens juntamente com padrões sintéticos de elementos foram irradiados no reator IEA-R1 e as atividades induzidas medidas em espectrômetro de raios gama para determinação de As, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, Fe, K, La, Mg, Mn, Rb, Sb, Sc, Se, U, V e Zn. A qualidade dos resultados analíticos foi avaliada pela análise de materiais de referência certificados. Seus resultados de desvios padrão relativos e de erros relativos foram inferiores a 15 % para a maioria dos elementos. Os valores de diferença padronizada ou En score obtidos foram inferiores a |1| indicando resultados satisfatórios. A homogeneidade da amostra de líquen foi avaliada tanto pela NAA como pela XRFS por meio das análises em replicatas e estes resultados indicaram a boa reprodutibilidade dos resultados em relação aos elementos determinados. Os resultados dos liquens da CUASO mostraram que as concentrações médias de As, Br, Ca, Cd, Co, Cr, Cs, Rb, Sb, Se e U foram mais altas do que daquelas das regiões consideradas não poluídas e para Fe, K, La, S, V e Zn foram da mesma ordem de grandeza. O estudo da correlação entre os elementos apresentou alta correlação (r > 0,7) para elementos originários de fontes naturais e antrópicas. A análise de componentes principais (PCA) aplicada aos resultados teve seis componentes principais, onde os componentes 1 e 2 corresponderam a 52,9 % da variância dos dados. Os resultados dos fatores de enriquecimento (FE) calculados entre os liquens da CUASO e de uma região considerada limpa foram maiores que 1 para maioria dos elementos, indicando que estes elementos podem ser de fontes antrópicas. Pelos resultados obtidos concluise que a origem dos elementos determinados nos liquens da CUASO pode ser atribuída a fontes como a resuspensão de partículas de solo e emissões antrópicas. / Air pollution has been a frequent topic of research, due to the effects that it can cause on the health of living organisms, environment and climate. In order to identify pollution sources and their effects, biomonitoring has been studied due to its low cost and possibility of sampling in wide geographic areas. In this study for passive biomonitoring of air pollution levels at the Cidade Universitária Armando Salles de Oliveira (CUASO), University of São Paulo campus, epiphytic lichens of Canoparmelia texana species were used. The lichens collected from tree barks at different sampling sites in the CUASO were cleaned, freeze-dried and ground for analyses. Lichen samples were analyzed by X - ray fluorescence spectrometry (XRFS) and neutron activation analysis (NAA). For XRFS, cylindrical pellets of samples were prepared to determine As, Br, Ca, Cl, Cr, Cu, Fe, K, Mn, Rb, S, Sr and Zn. For NAA, lichen sample aliquots along with synthetic elemental standards were irradiated both for short and long periods at the IEA-R1 nuclear research reactor. The induced activities were measured by a gamma ray spectrometer to determine As, Br, Ca Cd, Cl, Co, Cr, Cs, Cu, Fe, K, La, Mg, Mn, Rb, Sb, Sc, Se, U, V and Zn. The precision and accuracy of the results were evaluated by the analysis of certified reference materials (MRCs). Their results of relative errors and standard deviations were below 15% for most of the elements. The standardized difference or En score values were lower than |1| indicating satisfactory results. Replicate analyses of a lichen sample by XRFS and NAA, indicated good homogeneity of the sample for the elements determined. The lichen results showed that the mean concentrations of As, Br, Ca, Cd, Co, Cr, Cs, Rb, Sb, Se and U were higher in samples from CUASO than those from regions considered unpolluted. For Fe, K, La, S, V and Zn, they were of the same order of magnitude. The correlation study between the elements showed high correlation (r > 0.7) for elements originated from the natural and anthropogenic sources. The principal component analysis (PCA) applied to the results showed six major components, where components 1 and 2 accounted for 52.9 % of the variance of the data. Enrichment factors (EF) calculated for the results of lichens from CUASO and a region considered unpolluted were EF> 1 for most elements, showing that these elements may be from anthropogenic sources. From the results obtained in this study can be concluded that the elements found in lichens from CUASO can be originated from sources such as resuspension of soil particles and anthropogenic emissions.
376

Áreas afetadas por BTEX na região de Cubatão: isolamento de micro-organismos com potencial para biorremediação e impactos socio ambientais causados por estes compostos / Contaminated areas by BTEX in Cubatão: isolation of microorganisms with bioremediation potential and study of environmental and social impacts caused by these compounds

Avanzi, Ingrid Regina 04 July 2012 (has links)
A poluição do solo por uso de derivados de petróleo como o grupo de hidrocarbonetos denominado de BTEX (benzeno, tolueno, etil-benzeno e xilenos), apresenta grande risco às comunidades residentes próximas a esses locais. Esses compostos são tóxicos, comprovadamente cancerígenos e podem levar uma pessoa a morte, mesmo em concentrações extremamente baixas. O cidadão, muitas vezes não tem noção do que sejam estes contaminantes e o grande perigo que representam. Milhares de residências têm sido construídas sobre resíduos perigosos que continuam ativos, emitindo gases e/ou contaminando o lençol freático. Em particular, na região de Cubatão, o problema se agrava com o uso indevido de águas de rios e riachos, que por um processo de percolação, acabam sendo contaminados pelos poluentes presentes no solo, podendo ocorrer de o ponto de coleta de água ser próximo a um sítio contaminado. Este estudo relata o isolamento e caracterização de 4 cepas de bactérias isoladas de um solo contaminado com BTEX em Cubatão-SP, através da técnica de enriquecimento seletivo de culturas. A idéia é que estas cepas possam ser utilizadas em futuros processos de biorremediação (tratamento) destes solos. Além disso, o trabalho conta com o auxílio de programas sócio-ambientais existentes no Centro de Capacitação e Pesquisa em Meio Ambiente (CEPEMA-POLI-USP) os quais tem como um dos objetivos conscientizar a população carente cubatense, que faz uso indevido da água contaminada, aos perigos da exposição ao BTEX. / Contaminated soils by hydrocarbons known as BTEX (benzene, toluene, ethylbenzene and xylene), represent a risk to communities who live close to these places. These compounds are toxic, carcinogenic and can cause death to people, even in extremely small concentrations. Citizens often have no idea who and how hazardous are these contaminants. Millions of homes have been built on dangerous actives wastes, emitting gases and contaminating the groundwater. In particular, the problem is worst in Cubatão due inappropriate use of water from rivers and streams, which by a percolation process, contaminate soil. Most of times the water collected points are near from the contaminated site. This study reports the successful isolation and characterization of 4 bacteria strains isolated from an industrial soil in Cubatão-Brazil, using a culture enrichment technique. The idea is use these microorganisms in future soils bioremediation processes (treatment). This work have as partners, social and environmental programs from the Center for Training and Environmental Research (CEPEMA-POLI-USP), which has as goal educate poor people against dangers of BTEX.
377

Efeitos da poluição do ar sobre a função pulmonar: um estudo de coorte em crianças de Cubatão / Effects of air pollution on lung function: a cohort study in Cubatão children

Hofmeister, Vera Anna 11 September 1991 (has links)
É feita a análise da evolução de provas funcionais ventilatórias de dois grupos de crianças clinicamente sadias, residentes no Município de Cubatão, examinadas inicialmente em dois estudos transversais realizados respectivamente em 1983 (verão) e em 1985 (inverno). O princípio epidemiológico que norteou essa pesquisa foi a realização de um estudo de Coorte Não-Controlada, ou mais apropriadamente, um Estudo Ecológico Longitudinal, onde esses dois grupos de crianças foram anualmente submetidos a exames espirométricos no período de 1987 a 1989, mantida a estrita sazonalidade, ou seja, o Grupo de 1983 foi sempre reexaminado no verão, enquanto que o Grupo de 1985 sempre no inverno. Aproximadamente 1.110 crianças, oriundas de todas as áreas do Município foram submetidas a provas de função pulmonar utilizando-se espirômetro seco, com especial ênfase na análise do comportamento da Capacidade Vital Forçada (CVF), do Volume Expiratório Forçado no Primeiro Segundo (VEF1,0), do \"Peak-Flow\" ou Pico de Fluxo Expiratório (PFE), e do Fluxo Médio Expiratório Forçado (FMF25-75 por cento ), todos considerados como indicadores sensíveis às influências dos níveis de poluição atmosférica registrados em Cubatão. As informações concernentes à poluição do ar foram obtidas através dos relatórios de pesquisas efetuadas pela Companhia de Tecnologia de Saneamento Ambiental do Estado de São Paulo (CETESB) e envolveram a análise das estimativas de emissões das indústrias prioritárias de Cubatão, das concentrações horárias de material particulado (MP), dióxido de enxofre (SO2) e do ozona (O3) registradss nas estações amostradoras de Vila Parisi, Cubatão-Centro e Vila Nova no período de Novembro de 1983 a Dezembro de 1989. Também integrou o contexto de análise, a avaliação das principais metas do Programa de Controle de Poluição do Ar instituído pela CETESB na região a partir de 1984, com o objetivo de se verificar se as reduções pretendidas nos níveis de poluição do ar se fizeram acompanhar de melhorias nas provas funcionais pulmonares das crianças estudadas. Verificou-se que os episódios agudos de poluição do ar, principalmente devidos ao material particulado, mostraram algum decréscimo. No entanto, aqueles devidos a oxidantes fotoquímicos, representados pelos níveis de ozona, tiveram progressivo incremento no período de 1984 a 1988, tanto em relação ao número de episódios, como na persistência e gravidade dos mesmos. Os resultados espirométricos indicaram que em ambos os grupos de crianças a função pulmonar mostrou decrementos significativos, com perdas em tomo de 5 a 8 por cento ao ano, em média, quando comparados com os valores inicialmente registrados por ocasião dos estudos transversais. Apesar das reduções terem sido observadas em todas as variáveis espirométricas, os maiores decrementos verificaram-se principalmente nas medidas de fluxo (PFE e FMF25_75 por cento ), e coincidiram com o ano em que foram assinalados os mais graves episódios de poluição devida a oxidantes fotoquímicos. Os bairros Cota 95, Cota 200, Jardim das Indústrias e Vila Natal, localizados na área de influência do núcleo industrial químicofpetroquímico sobressairam-se como os mais críticos em função dos piores resultados espirométricos apresentados ao longo de todo o estudo. Pôde-se concluir que apesar da função pulmonar das crianças ainda não ter atingido níveis considerados como patológicos, mesmo registrando valores inferiores aos limites da normalidade nas variáveis de fluxo no ano de 1988, verificou-se que de ano para ano a função pulmonar vem decrescendo progressivamente indicando que esta vai sendo afetada pela exposição as poluentes da região e que as medidas de controle da poluição instituídas em Cubatão não tiveram a eficácia esperada. Continuando nessa mesma trajetória evolutiva, isso poderá acarretar sérios e irreparáveis prejuízos à saúde da população. É necessário, portanto, a adoção de urgentes medidas para a melhoria da qualidade do ar em Cubatão nos anos futuros, no intuito de prevenir sérios agravos à Saúde Pública. / The purpose of this study was to investigate the effects of exposure to air pollution on lung function of children. Two groups of clinically healthy children, living at different areas of the city of Cubatão, who had been submitted to lung function tests in a previous cross-sectional study (1983 summertime and 1985 wintertime) were annually reexamined using the same type of test during the period 1987 to 1989. On epidemiological basis this is a longitudinal study, where every individual of the two groups of children was measured at each ocasion, always in the same season of the previous examination. About 1,110 children from all areas of the city were examined once a year using dry spirometer, with special emphasis on FVC, FEV 1,0, PEF and FMF25-75 per cent measurements, since they were considered as those which could be most affected by the local air pollution. Information regarding the conditions of air pollution were obtained from the CETESB\'s written reports. They include the estimate emissions of the main industries of the region; the hourly concentrations of particulate matter, sulfur dioxide and ozone measured in the sampling stations located in Vila Parisi, Cubatão-Centro and Vila Nova during the October/1983 to December/1989 period and also the results of the Source Control Strategy introduced by CETESB since 1984. It was observed that the acute episodes of air pollution due to PM were reduced in number. However, those due to photochemicaf oxidants, mainly represented by ozone leveis, were progressively more frequent during the period from 1984 to 1988; both their number and their severity increased during this period. Spirometric results shows that in both groups of children the lung function was significantly impaired, with losses of 5 to 8 per cent per year, when compared with the initial values of the cross-sectional studies. Despite the fact that all lung function parameters decline, the flow (PFE and FMF2s-7s per cent ) values were those most affected and closely related to the most serious episodes of air pollution due to photochemical oxidants mainly those observed in 1988. Children living in the areas of Cota 95, Cota 200, Jardim das Indústrias and Vila Natal, situated in the nearest area of influence of the chemical and petrochemical industries, presented worst spirometric results than children living in other places of Cubatão. The lung function of the examined children did not attain pathological values, despite the fact of presenting the worst results in flow parameters during the year of 1988. It was observed that their lung function is progressively impaired year by year, a clear indication of the progressive effects of air pollution on their lung function, and if such impairment continues there will carne the time when lung function will probably reach a pathologicallevel. It is concluded that there is an urgent need of improving the quality of air of Cubatão to avoid serious Public Health problems in a quite near future.
378

Incômodo em relação ao ruído urbano entre trabalhadores de estabelecimentos comerciais no município de São Paulo / Annoyance related about urban noise among workers of commercial establishments in the city of Sao Paulo, Brazil

Petian, Andréa 10 October 2008 (has links)
Objetivos: 1) Estimar a prevalência do incômodo causado pelo ruído em trabalhadores de estabelecimentos comerciais no município de São Paulo. 2) Identificar o conhecimento e a opinião dos trabalhadores de estabelecimentos comerciais em relação ao ruído urbano 3) Identificar fatores sócio-demográficos associados ao incômodo, ao conhecimento e a opinião em relação ao ruído urbano. Métodos: Estudo transversal com 400 trabalhadores de estabelecimentos comerciais situados na zona central do município de São Paulo. O instrumento utilizado foi um questionário que contemplava questões sobre dados sócio-ambientais, ruído e aspectos relacionados aos incômodos por ele causados. As entrevistas foram realizadas no próprio estabelecimento onde o trabalhador atuava, em horário comercial. Mediu-se também o nível de pressão sonora no posto de trabalho, em um estabelecimento de cada rua visitada. Resultados: Dos 400 participantes, 59% eram do sexo feminino. A idade dos indivíduos variou entre 18 e 89 anos, com a mediana de 31 anos. 60% tinham nível escolar médio completo ou incompleto, 46% eram do setor de moda e 44% exerciam a função de balconista. Espontaneamente o ruído aparece em quarto colocado em incômodos no município e em primeiro em incômodo no local de trabalho e na residência. Do total, 65,75% achavam o local de trabalho ruidoso e 62,5% se mostraram incomodados com ruído neste local. O ruído interferia na atividade laboral de 43% dos trabalhadores sendo que a principal falar ao telefone (54%). Os principais problemas causados ou agravados pelo ruído, na opinião dos trabalhadores foram: perda auditiva, (72%), estresse (29%), irritabilidade (9%), dor de cabeça (7%), nervosismo (3%) e alterações do sono (1%). A maioria dos entrevistados referiu ter boa audição (96%). O sexo masculino e o maior nível de escolaridade se mostraram associados ao fato do trabalhador referir que o local de trabalho era ruidoso. Conclusões: A prevalência de trabalhadores que trabalhavam em estabelecimentos comerciais no município de São Paulo que referiram incômodo relacionado ao ruído no local de trabalho foi estimada em 62,5%. Referiram que o local de trabalho era ruidoso 65,75% trabalhadores e, o ruído do tráfego no local de trabalho incomodou 62% trabalhadores. Com os resultados deste estudo pode-se inferir que os trabalhadores conheciam tanto o risco físico do ruído, quanto o incômodo que ele pode causar. Os trabalhadores relataram que o ruído poderia causar ou agravar alguns problemas de saúde, principalmente a perda auditiva, estresse e irritabilidade / Objectives: 1) To evaluate the annoyance caused by noise among workers of commercial establishments of the city o Sao Paulo. 2) To find out the knowledge and opinion of these workers about the urban noise. 3) To identify socio-demographic factors associated to the annoyance, the knowledge and the opinion of the workers of commercial establishments in the city of Sao Paulo about the urban noise. Methods: This is a cross sectional study with 400 workers of commercial establishments located at the central area of the city of Sao Paulo. It was used a questionnaire that included questions about socio-environmental, noise and aspects related to the annoyances caused by them. The interviews were carried on at the workers workplace, during working hours. It was also measured the noise level at the workstation in one establishment of every street visited. Results: Of the 400 participants, 59% were female. The age ranged from 18 and 89 years old, with a median of 31 years. 60% of them had complete or incomplete high school educational level, 46% worked with clothes, and 44% were clerks. Noise appears spontaneously in fourth place among the annoyances at the workplace and at home. Of the participants 65.75% considered the workplace noisy, and 62.5% declared the felt annoyed by the noise at this place. Noise interfered with the professional activities of 43% of the workers, being talking to the phone the main activity disrupted (54%). Main problems caused or worsened by noise, for the workers, were: hearing loss (72%), stress (29%), irritability (9%), headache (7%), nervousness (3%), and sleep disturbances (1%). Most of the interviewed workers consider themselves as having a good hearing (96%). Male gender and higher schooling level were associated to the fact the worker mentions the workplace is noisy. Conclusions: The prevalence of people working at commercial establishments in the city of Sao Paulo who mentioned annoyance related to noise at the workplace was estimated to be 62.5%. 65.75% of the workers mentioned that the workplace was noisy, and the traffic noise was disturbing for 62% of the workers. From the results of this study it can inferred that the workers knew the physical risks associated to noise and the annoyances it can cause. The workers mentioned that noise could cause or worsen some health problems, especially hearing loss, stress and irritability
379

Efeitos da poluição crônica e aguda sobre a composição da ictiofauna do Rio dos Sinos, RS, BRASIL

Costa, Patrícia Fernandes da 30 October 2009 (has links)
Submitted by Nara Lays Domingues Viana Oliveira (naradv) on 2015-06-16T13:52:54Z No. of bitstreams: 1 PatriciaCostaBiologia.pdf: 61233 bytes, checksum: 22d13bd6e3b6610817a793613276d93b (MD5) / Made available in DSpace on 2015-06-16T13:52:54Z (GMT). No. of bitstreams: 1 PatriciaCostaBiologia.pdf: 61233 bytes, checksum: 22d13bd6e3b6610817a793613276d93b (MD5) Previous issue date: 2009-10 / UNISINOS - Universidade do Vale do Rio dos Sinos / O escoamento de efluentes domésticos e industriais nos sistemas hídricos pode afetar a composição das espécies de peixes nas comunidades. No Rio Grande do Sul, o Rio dos Sinos concentra, na região da planície, uma grande quantidade de indústrias coureiro calçadistas, metalúrgicas, têxteis e petroquímicas. Considerando a descarga contínua de efluentes no Rio dos Sinos e a ausência de conhecimentos das respostas das comunidades ictiícas diante de impactos dessa proporção, os objetivos do presente estudo foram: (1) Verificar os efeitos da poluição crônica sobre a composição e a diversidade das comunidades em uma escala temporal de aproximadamente dez anos (2) Averiguar os efeitos da poluição aguda em uma escala espacial, comparando um trecho afetado com outro não afetado pela mortalidade de aproximadamente 100 toneladas de peixes em outubro de 2006. As amostragens foram realizadas sazonalmente no período de setembro de 2007 a março de 2009, em seis locais do Rio dos Sinos: Fraga, Caraá, Parobé, São Leopoldo, Sapucaia do Sul e Canoas. Nas localidades de Fraga, Caraá, Parobé e São Leopoldo as coletas foram realizadas nos pontos idênticos aos do levantamento histórico de dez anos atrás. A metodologia aplicada consistiu em uma bateria de sete redes de espera e pesca elétrica. Um total de 8481 foi amostrado no presente estudo, pertencentes a sete ordens, 21 famílias e 68 espécies. A riqueza e a CPUE apresentaram diferenças significativas entre o estudo atual e o histórico. O trecho afetado pela mortalidade de peixes apresentou valores significativamente mais elevados de riqueza e de CPUE do que, o trecho não afetado. Em virtude dos resultados obtidos no presente estudo foi verificado que o aumento da riqueza e a diminuição da CPUE dos pontos em comum com o estudo histórico não estiveram relacionados com a proporção de espécies resistentes e sensíveis, mas sim com interações ecológicas. A poluição aguda e a crônica influenciaram temporal e espacialmente, respectivamente a composição das espécies. Entretanto, o Rio dos Sinos, após anos de exposição a poluentes de diversas origens ainda consegue manter condições favoráveis ao estabelecimento de muitas espécies. Entretanto, devido à descarga contínua de efluentes, muitas destas espécies poderão ser eliminadas, acarretando em uma diminuição profunda em sua diversidade.
380

Comparação da eficiência das técnicas de bombeamento, TPE e DPE para remediação de áreas contaminadas por hidrocarbonetos de petróleo /

Totti, Patrícia. January 2015 (has links)
Orientador: Chang Hung Kiang / Banca: Miguel Angel Alfaro Soto / Banca: Silvia Maria Ferreira Salvador / Resumo: O objetivo deste trabalho é a comparação da eficiência de três técnicas: bombeamento, TPE (Two Phase Extraction) e DPE (Dual Phase Extraction), na remediação de uma área contaminada com óleo diesel no Estado de Minas Gerais. Observações empíricas em sistemas de remediação em diversas áreas impactadas nos EUA e América Latina indicam um aumento significativo (superior a 30%) na remoção da massa total de contaminantes com a utilização de DPE em relação ao bombeamento e ao TPE, considerando as taxas de recuperação de massa nas fases livre, dissolvida e vapor. Para a comparação entre as técnicas foram efetuados ensaios de bombeamento, TPE e DPE em duas subáreas da área em estudo (denominadas área 1 e área 2), cujos dados foram comparados aos resultados de modelos teóricos. A partir da compilação de dados de sistemas de remediação em operação e da realização de ensaios de campo, foi possível confirmar o aumento significativo das vazões de extração utilizando a técnica de DPE em relação às vazões obtidas com as técnicas de bombeamento e TPE. Para a área 1, a utilização do DPE resultou em vazão de extração de líquido 38,5% maior que a obtida por bombeamento. Nos testes realizados na área 2, a utilização do DPE no poço de extração PE-01 resultou em aumentos de 39,68% na vazão de líquido em relação ao TPE e de 43,77% em relação ao bombeamento. Já para o poço PM-28, a vazão média obtida com o DPE foi 47,63% maior em relação ao TPE e 51,3% maior em relação ao bombeamento. A maior efetividade do DPE em relação ao bombeamento convencional pode ser explicada pelo aumento do gradiente de pressão, que ocasiona maior mobilidade de água e de LNAPL para o interior do poço. Em relação ao TPE, o DPE também foi mais efetivo, e, neste caso, as maiores vazões de líquido obtidas podem ser explicadas pelo rebaixamento causado pelo bombeamento, somado ao aumento de fluxo causado pelo... / Abstract: The objective of this study is to compare the effectiveness of three remediation techniques - pumping, TPE (Two Phase Extraction) and DPE (Dual Phase Extraction) - in a contaminated area with diesel in the state of Minas Gerais. Empirical observations for remediation systems in various areas affected in the US and Latin America indicate a significant increase (over 30%) in the total mass of contaminant removal with the use of DPE in relation to pumping and TPE, considering the recovery rates mass in free phase, dissolved phase and vapor phase. To compare the techniques the following methodologies were used: a) literature review; b) build systems operation data deployed in the area; c) conducting pumping tests, TPE and DPE in two sub-areas of the study area (known as Area 1 and Area 2); d) treatment and analysis of the obtained data; e) comparing the results with theoretical models. Using data compiled from field tests it was possible to confirm the significant increase in extraction flow using the DPE technique with respect to the flow obtained from pumping techniques and TPE. For area 1, the use of MPE resulted in the extraction liquid flow higher than the 38.5% compared to that obtained by pumping. In tests performed in area 2, the use of DPE in extraction well led to increase of 39.68% in the flow relative to the TPE and 43.77% with respect to the pumping. As for the PM-28 well, the average flow rate obtained with DPE was 47.63% higher compared to that of TPE and 51.3% higher compared to the pumping. The greater effectiveness of DPE compared to conventional pumping can be explained by the increased pressure gradient, which increase water and LNAPL yield into the well. With respect to TPE, DPE was also more effective,and, in this case, the highest net flow obtained can be explained by the drawdown induced by pumping, coupled with the augmented gradient caused by the application of vacuum / Mestre

Page generated in 0.04 seconds