• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 121
  • 27
  • 27
  • 27
  • 27
  • 25
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 121
  • 121
  • 65
  • 47
  • 40
  • 28
  • 26
  • 24
  • 21
  • 20
  • 18
  • 17
  • 16
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Influência do tratamento de superfície na resistência à flexão e na transformação de fase de zircônia tetragonal policristalina estabilizada por óxido de ítrio (y-tzp) /

Michida, Silvia Masae de Araujo. January 2010 (has links)
Resumo: Neste estudo avaliou-se a influência do tratamento de superfície para cimentação na resistência à flexão de 4 pontos de zircônia tetragonal policristalina estabilizada por óxido de ítrio (Y-TZP). Por meio de blocos pré-sinterizados de Y-TZP (InCeram 2000 YZ Cubes, Vita Zahnfabrik) foram confeccionadas 120 barras (20mm x 4mm x 1,2mm) de acordo com a norma ISO 6872:2008 e aleatoriamente divididas em 4 grupos: Grupo 1: silicatização (Cojet 30 μm) (n=29); Grupo 2: jateamento com óxido de alumínio (44 μm) (n=29); Grupo 3: ponta diamantada de granulação extra-fina (30 μm) (n=27); Grupo 4: (controle) sem tratamento de superfície (n=29). Em seguida, todas as amostras foram submetidas ao ensaio de flexão de 4 pontos (imersos em água destilada à 370C) em máquina de ensaio universal com velocidade de 0,5 mm/min até o rompimento das mesmas. A análise de difração de raios-X foi utilizada para determinar a transformação de fase. A microestrutura da Y-TZP e o padrão de tratamento de superfície foram analisados por meio de perfilometria óptica e microscopia eletrônica de varredura. Os dados de resistência à flexão foram estatisticamente analisados por meio de ANOVA 1-fator, teste de Tukey HSD (α=0,05) e Weibull (m=módulo; σ0=resistência característica). As médias±desvio-padrão (MPa) foram os seguintes: G1:1207,1±229,7a; G2: 1369,7±272,3a; G3: 874,4±365,4b e G4: 1196,2±284,2a. Os valores de (m) e (σ0) foram: G1: 6,0 e 1300,28; G2: 5,9 e 1477,88; G3: 2,6 e 985,901 e G4: 4,5 e 1308,12. Concluiu-se que a utilização de pontas diamantadas de granulação extra-fina deve ser evitada nos procedimentos prévios à cimentação resinosa de Y-TZP / Abstract: This study evaluated the influence of surface treatment on 4-point bending test of yttrium stabilized policristaline tetragonal zirconia (Y-TZP). From Y-TZP blocks (InCeram 2000 YZ Cubes, Vita Zahnfabrik) were obtained 120 bars (20mm×4mm×1.2mm) according to norm ISO 6872:2008 and randomly divided in 4 groups: Group 1: silicatization (Cojet 30 μm) (n=29); Group 2: sandblasting with aluminium oxide (44 μm) (n=29); Group 3: fine coarse diamond bur (30 μm) (n=27); Group 4: (control) without surface treatment (n=29). As follow, all samples were submitted to the 4-point bending test (immersed in distilled water at 370C) in an universal testing machine with cross-head speed of 0.5 mm/min until the rupture of the samples. X-ray diffraction analysis was utilized to quantify the monoclinic phase. The microstructure of Y-TZP and pattern of surface treatment were analyzed by optic profilometer and scanning electron microscopy. The data of flexural strength (σ4p) were statistically analyzed by 1-factor ANOVA, Tukey HSD (α= 0.05) and Weibull (m= modulus, σ0 = characteristic strength). The mean±standard deviation (MPa) were the following: G1:1207.1±229.7a; G2: 1369.7±272.3a; G3: 874.4±365.4b and G4: 1196.2±284.2a. The values of (m) and (σ0) were: G1: 6.0 and 1300.28; G2: 5.9 and 1477.88; G3: 2.6 and 985.901 and G4: 4.5 and 1308.12. It was concluded that silicatization and sandblasting increased the flexural strength of Y-TZP, diminished the roughness of surface and present higher reliability for cementation of Y-TZP restorations / Orientador: Estevão Tomomitsu Kimpara / Coorientador: Mutlu Özcan / Banca: Paulo Francisco César / Banca: Alfredo Mikail Melo Mesquita / Banca: Rubens Nisie Tango / Banca: Fernando Eidi Takahashi / Doutor
112

Cerâmicas feldspáticas estratificadas e em blocos para sistema CAD/CAM : avaliação da topografia superficial, formação de biofilme inicial e viabilidade celular /

Contreras, Lisseth Patricia Claudio January 2017 (has links)
Orientador: Marco Antonio Bottino / Banca: Laís Regiane da Silva Concilio / Banca: Alexandre Luiz Souto Borges / Resumo: O objetivo deste estudo foi avaliar a topografia e a formação de biofilme na superfície de cerâmicas feldspáticas obtidas através de duas técnicas de confecção e dois tratamentos de superfície, assim como avaliar a viabilidade do crescimento de fibroblastos gengivais humanos (FMM-1) sobre estes materiais. Foram confeccionados 52 blocos de cada tipo de cerâmica feldspática: VM9 obtida através da técnica da estratificação e cerâmica Vita Blocs Mark II (VMII) para o sistema CAD/CAM (ambas, Vita Zahnfabrik). As superfícies dos blocos foram padronizadas em politriz nas dimensões de 4,5 x 4,5 x 1,5 mm e os blocos foram divididos em dois tratamentos de finalização de superfície: polimento com borrachas Ceramisté + pasta de polimento e aplicação de glaze spray + sinterização. Os parâmetros de rugosidade Ra e Rsm foram mensurados através de um rugosímetro de contato. As amostras foram esterilizadas e, em seguida contaminadas (n=10) para formação de biofilme heterotípico inicial de S. mutans, S. sanguinis e C. albicans, cuja aderência foi quantificada por contagem de unidades formadoras de colônias (UFC/mL). O teste MTT foi empregado para avaliação da viabilidade celular dos materiais ao crescimento de fibroblastos gengivais humanos (FMM-1) em 24 h e 7 dias (n=12). Foram realizadas análises qualitativas da superfície dos espécimes através de microscopia eletrônica de varredura (MEV) e perfilometria óptica 3D. A energia livre de superfície (ELS) foi calculada a partir de análises de gon... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The Objective of this study was to evaluate the topography and surface biofilm formation of feldspathic ceramics obtained through two techniques of preparation and two surface treatments, as well as to evaluate the viability of human gingival fibroblasts (FMM-1) growth on these materials. A total of 52 blocks of each type of feldspathic ceramic were made: VM9 obtained by the stratification technique and Vita Blocs Mark II (VMII) for the CAD/CAM system (both, Vita Zahnfabrik). The blocks' surfaces were standardized in a polishing machine to the dimensions of 4.5 x 4.5 x 1.5 mm and blocks were divided into two surface finishing treatments: polishing with Ceramisté rubbers + polishing with paste; and glaze application + sintering. The Ra and RSm roughness parameters were measured through a contact rugosimeter. Samples were sterilized and then contaminated (n = 10) for initial heterotypic biofilm formation of S. mutans, S. sanguinis and C. albicans, whose adherence was quantified by counting colony forming units (CFU/mL). The MTT test was used to evaluate the cellular viability of the materials to the growth of human gingival fibroblasts (FMM-1) in 24 h and 7 days (n=12). Qualitative analyzes of the specimens' surface were performed using a scanning electron microscopy (SEM) and 3D optical profilometry. Surface free energy (SFE) was calculated from goniometry analyzes of polar and apolar liquids in 10 samples of 15 x 15 x 1.5 mm. The results of Ra, RSm and ELS were subjected to 2-way ANOVA (Material x surface treatment) followed by Tukey's test (both, α=95%), and UFC (material x surface treatment x microorganisms) and MTT (material x surfacetreatment x time) data were evaluated by 3-way ANOVA and Tukey's test (α=95%). SEM and profilometry images were described. The polished ceramics presented lower roughness (Ra p=0.015; RSm p=0.049) ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
113

Avaliação pelo método dos elementos finitos de cargas axiais aplicadas sobre implantes e componentes protéticos com diversas inclinações

Ferreira, Luciano Pedrin Carvalho [UNESP] 24 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-24Bitstream added on 2014-06-13T20:37:51Z : No. of bitstreams: 1 ferreira_lpc_me_arafo.pdf: 814817 bytes, checksum: a1d0c7e92cf1ea3e5ea3d8dc8b1d5863 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O stress causado pela mastigação sobre implantes que se encontram muito inclinados, pode levar a tensões indesejáveis, causando até o fracasso da restauração. Este trabalho teve como objetivo apresentar através de simulações computacionais, as concentrações de tensões no implante e osso de suporte quando sua inclinação for maior que 30°. Para avaliação comportamental das tensões no implante/osso circundante, foi desenvolvido um modelo representando o primeiro pré-molar inferior. Foi utilizado o método dos elementos finitos bidimensional. Um modelo simulando um implante hexágono externo (4 mm x 15 mm) foi confeccionado, sofrendo inclinações de 30°, 35° e 40°, com uma carga de 100 N e 350 N, incidindo no sentido vertical. Através do enceramento de um componente ucla, a inclinação da coroa protética foi restabelecida. Os materiais de cobertura selecionados foram: porcelana, cerômero e o metal. No implante sem inclinação (controle), a tensão máxima ficou concentrada no local de aplicação da carga. Para os implantes angulados, as tensões se concentraram no local de aplicação da carga, no osso cortical e no terço cervical e médio do implante, no lado da inclinação, independentemente do material de cobertura utilizado. Com a limitação deste estudo, as cargas verticais são bem aceitas pelos implantes sem inclinação, mas quando angulados, a concentração de stress é muito maior no lado em que ocorre a inclinação. / Tensions caused by mastication on very inclined implants can result in undesirable stresses as well as restoration failures. By means of computational simulations, present the concentrations of stresses on the implant and supporting bone when the inclination is greater than 30°. A model representing the first mandibular premolar was developed to evaluate stress behavior in the surrounding implant/bone, using the bidimensional finite element method. A model simulating an external hexagon implant (4 mm x 15 mm) was made, with 0°, 30°, 35° and 40°, a load of 100 N and 350 N, occurring in the vertical direction. The correct prosthetic crown inclination was reestablished by means of a UCLA component. The selected covering materials were: porcelain, ceromer and metal. In an implant without inclination (control), maximum stress was concentrated in the place of load application and on the middle third of the implant. For angled implants, the stress was concentrated on the side of the inclination, on the cortical bone and on the cervical and medium third of the implant. The covering material had similar behauvior. Within the limitations of this study, the vertical loads were well accepted by the implants without inclination, but when implants were angled, the stress concentration was much greater on the side inclination. The finite element method used to investigate inclined implants in the posterior area of the jaw, indicated that there was higher stress concentration where the inclination was. However, clinical studies are important to evaluate the amount of load necessary for bone reabsorption.
114

Efeito do preaquecimento de cimentos resinosos na resistência de união de cerâmica à dentina / Effect of resin cements preheating on ceramics bonding to dentin

Castro, Fernanda Maria de 21 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-14T13:38:51Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese - Fernanda Maria de Castro - 2014.pdf: 1978045 bytes, checksum: bc85b184ec55cdac0ec38892e07c936d (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-14T13:39:55Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese - Fernanda Maria de Castro - 2014.pdf: 1978045 bytes, checksum: bc85b184ec55cdac0ec38892e07c936d (MD5) / Made available in DSpace on 2015-01-14T13:39:55Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese - Fernanda Maria de Castro - 2014.pdf: 1978045 bytes, checksum: bc85b184ec55cdac0ec38892e07c936d (MD5) Previous issue date: 2014-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Evaluate bond strength (BS) between leucite glass ceramic and dentin when luted with conventional and self-adhesive resin cements, preheated or not, through a microtensile bond strength test (μTBS) and examine the fracture mode. Materials and Methods: Twenty-four extracted human third molars were sectioned for the removal of the occlusal enamel and root portion, and ramdomly divided into four groups, with four teeth for each group. Twenty-four leucite glass ceramic discs (IPS Empress Esthetic, Ivoclar Vivadent, Schaan, Liechtenstein) were obtained and luted to the teeth, following manufacturers instructions, divided in four (4) groups: GI – RelyX ARC (3M ESPE) + Scotchbond Multi-Purpose Plus (3M ESPE); GII – RelyX ARC preheated 60°C + Scotchbond Multi-Purpose Plus; GIII – RelyX U200; GIV – RelyX U200 preheated 60°C. They were cut into 1 mm2 specimens, stored in destilled water for 24hs at 25±2°C and submitted to the μTBS in a universal testing machine. Each fragment of the specimen was analysed in stereoscopic microscope (45X) to classify the failure mode. SEM images of a representative pair of each failure mode were obtained. Data were statisticaly analysed with Variance Analysis (ANOVA) and Tukey (α=0.05). Results: There were statistical significant differences on BS between the cements RelyX ARC and U200 (p<0.05) in both groups with and without heating. There were no significant differences on BS between groups GI (12.98 MPa) and GII (12.87 MPa) and between GIII (6.81 MPa) and GIV (8.58 MPa) for both cements tested (p>0,05). The most common failure mode observed in all groups was adhesive, followed by mixed and ceramic cohesive failure; no group presented dentin cohesive failure. Conclusion: Preheating of resin cements to 60ºC did not enhance BS for both cements. BS for conventional resin cement was greater than self-adhesive resin cement. Adhesive failure was the most common failure mode. / Avaliar a resistência de união (RU) entre uma cerâmica vítrea reforçada por leucita e a dentina com a utilização de cimentos resinosos convencional e autoadesivo, com e sem aquecimento, por meio do teste de microtração (μTBS) e verificar o padrão de fratura. Material e métodos: vinte e quatro (24) terceiros molares humanos extraídos foram seccionados para remoção da porção radicular e do esmalte oclusal e aleatoriamente divididos em quatro (4) grupos. Vinte e quatro discos de cerâmica vítrea reforçada por leucita (IPS Empress Esthetic, Ivoclar Vivadent, Schaan, Liechtenstein) foram obtidos e cimentados aos dentes seccionados, de acordo com as especificações do fabricante, obtendo-se quatro (4) grupos: GI – RelyX ARC (3M ESPE) + Scotchbond Multi-Purpose Plus (3M ESPE); GII – RelyX ARC preaquecido 60°C + Scotchbond Multi-Purpose Plus; GIII – RelyX U200 (3M ESPE); GIV – RelyX U200 preaquecido 60°C. As amostras foram cortadas para obtenção de espécimes de 1,0 mm2, armazenadas por 24 h em água destilada a 25±2°C e submetidas ao teste de microtração em máquina de ensaio universal. Cada parte do espécime foi analisada em microscópio estereoscópico (45X) para visualização e classificação do padrão de fratura. Foram realizadas fotomicrografias em microscopia eletrônica de varredura de um par representativo de cada tipo de fratura. Os dados obtidos foram analisados estatísticamente por Análise de Variância (ANOVA) e teste de Tukey (α=0,05). Resultados: houve diferença estatisticamente significante entre a RU dos cimentos RelyX ARC e U200 (p<0,05), com e sem aquecimento. Não houve diferença significante entre a RU dos grupos GI (12,98 MPa) e GII (12,87 MPa) e entre GIII (6,81MPa) e GIV (8,58 MPa) (p>0,05). A falha adesiva foi o tipo de falha mais observado em todos os grupos, seguida pela falha mista e coesiva em cerâmica; nenhum grupo apresentou falhas coesivas em dentina. Conclusão: o preaquecimento dos cimentos resinosos a 60ºC não influenciou significantemente na RU entre a dentina e a cerâmica para ambos os cimentos, sendo a RU do cimento resinoso convencional superior à RU do autoadesivo. O padrão de fratura mais observado foi a falha adesiva.
115

"Influência do pH de armazenamento no crescimento subcrítico de trincas de porcelanas odontológicas com diferentes microestruturas" / Influence of pH of storage in the subcritical growth of trincas of odontológicas porcelains with different microstructures

Marcelo Mendes Pinto 05 July 2006 (has links)
O objetivo do trabalho foi determinar o efeito do pH de armazenamento (pH 3,5; 7,0 e 10,0) nos parâmetros de crescimento subcrítico (n e ? f0) de duas porcelanas odontológicas com diferentes microestruturas (com e sem leucita). A hipótese testada foi a de que o pH do meio afeta os parâmetros de crescimento subcrítico dos dois materiais. Duas porcelanas feldspáticas foram avaliadas: 1) Ultropaline Dentina (UD), JenDental/Ucrânia; 2) Veneer Material 7 (VM7), Vita/Alemanha. A porcelana UD é composta de matriz vítrea com dispersão de partículas de segunda fase de leucita, enquanto a porcelana VM7 apresenta exclusivamente fase vítrea. Espécimes em forma de disco com características específicas (diâmetro e espessura) foram sinterizados com os dois materiais seguindo o ciclo proposto pelos fabricantes. Os espécimes foram armazenados em diferentes soluções com pH específico (3,5; 7,0 e 10,0) por 10 dias antes de serem testados. Os parâmetros de fadiga foram obtidos pelo método de fadiga dinâmica utilizando o ensaio de resistência à flexão biaxial (“piston on three balls”) com cinco taxas constantes de carregamento (0,01; 0,1; 1; 10 e 100 MPa/s). A tenacidade à fratura e a dureza foram avaliadas pelo método da fratura por indentação (IF). A microestrutura dos materiais foi analisada por meio de microscopia eletrônica de varredura, difração de raios X e análise química por fluorescência de raios X. O efeito do pH no coeficiente de susceptibilidade ao crescimento subcrítico (n) foi diferente para os dois materiais estudados. Os resultados mostraram que, para a porcelana vítrea (VM7), o valor de n não variou significativamente em função do pH. Para a porcelana com leucita (UD), houve uma diminuição do valor de n quando a armazenagem foi feita em pH 3,5. O efeito do pH no parâmetro escalar (? f0) também foi diferente para os dois materiais. Para a porcelana VM7, tanto o pH ácido como o básico resultaram em menores valores de resistência em relação ao pH neutro. Para a porcelana UD, somente a armazenagem em pH básico resultou em queda do valor de ? f0. Os valores de dureza dos dois materiais diminuíram conforme o pH foi aumentado, porém, somente a diferença entre o grupo armazenado a seco e o grupo armazenado em pH 10 foi estatisticamente significativa para as duas porcelanas. Com relação à tenacidade, o pH não influenciou significativamente nas médias obtidas para os dois materiais. Com base nos resultados foi possível concluir que o efeito pH do meio de armazenamento no crescimento subcrítico de porcelanas dontológicas varia de acordo com a microestrutura do material. / The objective of the study was to determine the effect of the pH of the storage medium (pH 3,5; 7,0 e 10,0) on the fatigue parameters (n and ? f0) of two dental porcelains with different microstructures (with and without leucite). The hypothesis tested was that the pH affects the fatigue parameters of both materials. The dental porcelains tested were: 1) Ultropaline Dentin (UD), JenDental/Ucraine; 2) Veneer Material 7 (VM7), Vita/Germany. UD contains leucite and VM7 is only vitreous. Disc specimens were produced with both materials following manufacturers’ firing cycles. The specimens were stored in water solutions with different pHs (3,5; 7,0 e 10,0) for 10 days and after that the fatigue parameters were obtained by means of the dynamic fatigue test. Hardness and fracture toughness were determined by means of the indentation fracture technique. Microstructural analysis of the materials was also carried out. The effect of the pH in the fatigue parameters was different for the two materials tested. The results showed that, for VM7, the n value did not vary as a function of the pH. For porcelain UD, the n value was lower when the specimens where stored in pH 3,5. The parameter ? f0 was also affected by the pH. For both materials, the storage in basic pH resulted in a decrease in the ? f0 value. The hardness of both materials decreased with the increase in the pH of the storage media, and fracture toughness was not affect by the pH. Based on the results, it was possible to conclude that the effect of the pH (of the storage media) on the fatigue parameters of the dental porcelains studied varied according to the porcelain’s microstructure.
116

Efeito da troca iônica nos parâmetros de Weibull, de crescimento subcrítico de trincas e no comportamento de curva R de uma porcelana odontológica / Efffect of ion exchange on Weibull and slow crack growth parameters and R-curve behavior of a dental porcelain

Rosa, Vinicius 06 July 2007 (has links)
O objetivo deste estudo foi avaliar o efeito da temperatura de troca iônica (TI) nas propriedades mecânicas da porcelana Ultrapaline ST e o efeito da TI nos parâmetros de crescimento subcrítico de trincas (SCG) (coeficiente de SCG - n, parâmetro escalar - ?f0), de Weibull (resistência característica - ?0, módulo de Weibull - m) e no comportamento de curva R desta porcelana. 250 discos (12 mm diâmetro x 1 mm espessura) foram fabricados de acordo com as instruções do fabricante, usinados em retificadora plana e polidos até 1 ?m. Para determinar o efeito da temperatura de TI na resistência à flexão biaxial (?), dureza (H) e tenacidade à fratura (KIc), 40 discos foram divididos em 4 grupos (n=10): GI (controle) - sem TI; e GII, GIII e GIV submetidos a TI com KNO3 por 15 min a 450°C; 470°C e 490°C, respectivamente. A ? foi determinada por \"pistão sobre três esferas\" em saliva artificial a 37°C a 10 MPa/s. Para dureza e tenacidade à fratura, foram feitas 3 indentações Vickers em cada espécime (2kg, 30s) e as diagonais e trincas radiais foram medidas e os valores de H e KIc calculados. As médias e desvios-padrão para ? (MPa), H (GPa) e KIc (MPa.m1/2) foram: GI: 57,95 ± 8.97, 7,24 ± 0,79 e 1,14 ± 0,14; GII: 125,04 ± 23,58, 5,80 ± 0,14, 2,62 ± 0,14; GIII: 133,00 ± 11,00, 5,88 ± 0,45, 2,54 ± 0,22; GIV: 137,67 ± 12,05, 5,88 ± 0,17, 2,57 ± 0,10, respectivamente. Para determinação dos parâmetros de SCG e de Weibull, 140 espécimes foram divididos em 2 grupos: GC (controle) e GT (submetidos à TI por 15 min a 470°C). Para determinação de n e de ?f0, 50 espécimes de cada grupo foram testados em saliva artificial a 37°C em flexão biaxial em uma das seguintes taxas de tensão: 10-2, 10-1, 100, 101 e 102 MPa/s. Para determinação dos parâmetros de Weibull, mais 20 espécimes de cada grupo foram ensaiados na taxa de 100 MPa/s. Os valores de n, ?f0, m e ?0 foram, respectivamente (valores entre parênteses representam intervalos de confiança de 95%): 24,1 ± 2,5; 58,1 ± 0,01; 13,8 (10,0 a 18,8) e 60,4 (62,2 a 58,5) para GC e 36,7 ± 7,3; 127,9 ± 0,01; 7,4 (5,3 a 10,1) e 136,8 (129,1 a 144,7) para GT. Para determinação do efeito da TI no curva R, 7 espécimes de cada grupo receberam uma indentação Vickers em uma das seguintes cargas de indentação (kg): 0,18; 0,32; 0,56; 1,0; 3,2. Após armazenados ao ar por 24 h os espécimes foram ensaiados a 10 MPa/s em saliva artificial a 37°C. Os parâmetros ?, ?, q foram, respectivamente: 62,57; 0,12 e 0,2857 para GC e 161,50; 0,34 e -0,0074 para GT. Os valores de k variaram de 0,371 a 0,515 para GC e de 1,240 a 0,804 para GT. Não houve diferença nas propriedades mecânicas entre as três temperaturas de TI testadas. A TI promoveu aumento significativo do valor de n, ?f0 e ?0, entretanto resultou em diminuição do valor de m e também suprimiu o comportamento de curva R, presente no material antes da realização da TI. / The objectives of this study were to determine the influence of different ion exchange (IE) temperatures on mechanical properties of a dental porcelain Ultrapaline ST and the effect of IE on slow crack growth (SCG) (coefficient of SCG - n, scale parameter - ?f0) and Weibull parameters (characteristic strength - ?0; Weibull modulus - m) and R-curve behavior of this porcelain. 250 specimens (12 mm diameter x 1 mm height) were fabricated according to the manufacturer\'s instructions, grounded with a surface-grinding device and polished up to 1?m. To determine the effect of IE temperature on biaxial flexural strength (?), hardness (H) and fracture toughness (KIc), 40 specimens were divided in four groups (n=10) as follow: GI - control (no ion exchange); GII, GIII and GIV submitted to IE with KNO3 for 15 min at 450°C; 470°C e 490°C, respectively. The ? was determined using a piston-on-three-balls device, in artificial saliva at 37°C and constant loading rate of 10 MPa/s. For hardness and fracture toughness, 3 Vickers indentations (2kg, 30s) were made on each specimen. The diagonals and radial cracks were measured in order to calculate H and KIc. Mean and standard deviations values of ? (MPa), H (GPa) and KIc (MPa.m1/2) were: I: 57.95 ± 8.97; 7.24 ± 0.79; 1.14 ± 0.14; II: 125.04 ± 23.58; 5.80 ± 0.14; 2.62 ± 0.14; III: 133.00 ± 11.00; 5.88 ± 0.45; 2.54 ± 0.22; IV: 137.67 ± 12.05; 5.88 ± 0.17; 2.57 ± 0.10, respectively. To determine the effect of IE on SCG and Weibull parameters, 140 specimens were divided in 2 groups: GC (control) and GIE (submitted to IE at 470°C for 15 min). To determine the SCG parameters, 10 specimens of each group were tested in biaxial flexural strength in each one of five constant stress rates: 10-2, 10-1, 100, 101 e 102 MPa/s. To determine the Weibull parameters, 20 specimens of each group were tested in the stress rate of 100 MPa/s. The n, ?f0, m and ?0 (values in parenthesis represent the confidence interval) were: 24.1 ± 2.5; 58.1 ± 0.01; 13.8 (10.0 to 18.8) and 60.4 (62.2 to 58.5) for GC and: 36.7 ± 7.3; 127.9 ± 0.01; 7.4 (5.3 to 10.1) and 136.8 (129.1 to 144.7) for GIE, respectively. To determine the effect of IE on R-curve behavior, 7 specimens of each group received a Vickers indentation in one of the following indentation loads (kg): 0.18; 0.32; 0.56; 1.0; 3.2. After stored on air for 24 h, the specimens were tested biaxial flexure strength in artificial saliva at 37°C in a stress rate of 10 MPa/s. The ?, ?, q parameters were, respectively: 62.57; 0.12 and 0.2857 for GC and 161.50; 0.34 and -0.0074 for GIE. The values of k varied from 0.371 to 0.515 for GC and from 0.34 to 0.0074 for GIE. There are no differences on mechanical properties among the three IE temperatures tested. The IE promoted significantly increase of n, ?f0 and ?0 however, decreased the m value and suppressed the R-curve behavior originally present on material before the IE.
117

Análise da distribuição das tensões em restaurações cerâmicas sobre dente natural e implante por meio do método dos elementos finitos /

Freitas Júnior, Amilcar Chagas. January 2008 (has links)
Resumo: As restaurações cerâmicas têm proporcionado resultados satisfatórios estética e biomecanicamente. Porém, a comparação dos dados sobre a distribuição das tensões nos casos de diferentes restaurações suportadas por dente ou por implante é inconclusiva. O objetivo desse estudo foi avaliar, através da análise de elementos finitos bidimensional, a distribuição interna das tensões nos materiais e estruturas de suporte em função de duas possibilidades restauradoras em cerâmica (faceta laminada e coroa total) e dois tipos de suportes (dente natural e implante). Foram confeccionados 8 (oito) modelos (M) no programa AutoCad 2006, variando o tipo de suporte e restauração: MA (controle) - representação do incisivo central maxilar, hígido, seccionado sagitalmente; MB1, MB2 e MB3 - semelhantes ao MA, restaurados com faceta laminada pelo sistema IPS Empress, IPS Empress Esthetic e Laminado Procera, respectivamente; MC1 e MC2 - semelhantes ao MA, com coroa total pelo sistema IPS Empress 2 (MC1) e Procera AllCeram (MC2); MD1 e MD2 - porção coronária semelhante ao MC1 e MC2, respectivamente, com a presença de um implante osseointegrado (Sistema Bränemark - 4,3 X 15,0 mm) e pilar em zircônia. Para análise numérica (Ansys 10.0), os modelos foram carregados (C) sob duas condições (50N): C1 - 45º de inclinação com o longo eixo dental, no terço médio da face palatina; C2 - perpendicular à borda incisal. Adicionalmente, uma terceira condição foi adotada para o MA: C3 - 50N na borda incisal paralelo ao longo eixo dental. Foram obtidas a tensão equivalente de von Mises (σvM) e a máxima tensão principal em tensão (σmax.t) e compressão (σmax.c). Observou-se que C3 proporcionou a menor variação de svM no dente e estruturas de suporte quando comparada à C1 e C2. / Abstract: The ceramics restorations have provided excellent aesthetic and biomechanical clinical results. However, the data about the stress distribution in tooth and implant-supported restorations are inconclusive. Using two-dimensional finite element analysis, the purpose of this study was to evaluate the stress distribution in the materials and support structures based on two ceramics restorative possibilities (laminate veneer and ceramic crown) and two support structures (tooth and implant). 8 models (M) were built in the program AutoCAD 2006, varying the restorations and their support structures: MA (control) - an intact maxillary central incisor in sagittal cut; MB1, MB2 and MB3 - similar to MA, with laminate veneers of IPS Empress, IPS Empress Esthetic and Procera veneer, respectively; MC1 and MC2 - similar to MA, with a full crown of IPS Empress 2 (MC1) and Procera AllCeram (MC2); MD1 and MD2 - coronary portion similar to MC, with an osseointegrated implant (Bränemark System - 4.3 X 15.0 mm) and zircon abutment. To the numerical analysis (Ansys 10.0), the following loadings (L) were performed (50N): L1 - on the medium third of the lingual face, in 45º with the dental long axis; L2 - perpendicular to the incisal edge; L3 - 50N in the incisal edge parallel to the tooth long axis (only for the natural tooth). The von Mises equivalent stress (σvM) and maximum principal stress in tension (σmax.t) and compression (σmax.c) were obtained. It was observed that L3 provided the smallest variation of σvM in the tooth and support structures in comparison with L1 and L2. The beam3 elements used for the periodontal ligament modeling showed an appropriate behavior for parallel loading. In the MB and MC, the ceramics increased the σvM in the adhesive interface, mainly for Procera. In the models with implant, the IPS Empress2 showed higher σvM than that for Procera AllCeram. / Orientador: Eduardo Passos Rocha / Coorientador: Paulo Henrique dos Santos / Banca: Altair Antoninha Del Bel Cury / Banca: Wirley Gonçalves Assunção / Mestre
118

Laminados cerâmicos em pré-molares: análise tridimensional pelo método dos elementos finitos

Archangelo, Carlos Marcelo [UNESP] 31 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-31Bitstream added on 2014-06-13T20:06:16Z : No. of bitstreams: 1 archangelo_cm_dr_araca.pdf: 3340208 bytes, checksum: 53b104f834f13f3fac3b5838d3d64527 (MD5) / Objetivo: O objetivo do presente estudo foi avaliar através do método dos elementos finitos tridimensional (3D FEA), o comportamento mecânico de uma faceta laminada de cerâmica e do cimento resionoso em um 1o pré-molar maxilar, variando a redução (parcial ou total) da cúspide vestibular. Material e método: Baseado em imagens micro-tomográficas (μCT) 2 modelos (M) tridimensionais foram construídos no programa Solidworks 2007 variando a redução da cúspide vestibular, sendo Mp o modelo composto pelo dente pré-molar restaurado com uma faceta laminada de cerâmica, com redução parcial da cúspide vestibular e Mt, o modelo semelhante ao Mp, porém com redução total da cúspide vestibular. O programa de elementos finitos ANSYS Workbench 10.0 foi utilizado para realizar as análises. O carregamento (150 N) foi aplicado próximo à ponta de cúspide vestibular, com 45º de inclinação. Foram utilizados os critérios da máxima tensão principal ( max) e da máxima tensão cisalhante ( shear) na faceta laminada e na camada de cimento resinoso. Resultados: O Mt mostrou menor shear em 9 das 12 áreas analisadas quando comparado ao Mp. O Mp mostrou menor variação da max (de -3,13 para 14,4 MPa) que o Mt para a lâmina de cerâmica (de -2,08 para 24,3 MPa) A camada de cimento apresentou variação de max semelhante entre os Mp e Mt. Os critérios de tensões utilizados não evidenciaram valores além dos limites estabelecidos para a falha estrutural do material estudado. Conclusão: O laminado cerâmico e a camada de cimento resinoso apresentaram comportamento mecânico favorável para a restauração do pré-molar frente ao carregamento adotado. O tipo de redução de cúspide não influenciou no aumento expressivo das tensões principal e cisalhante. O Mp apresentou menores valores de max em tração quando comparado ao Mt. O Mp e o Mt apresentaram comportamento favorável com relação as forças cisalhantes, sendo as maiores tensões. / Objectives: Using 3-D finite element analysis (FEA) and μCT data, the aim of this study was to evaluate the behavior of the laminate veneer and the resin luting cement in a maxillary premolar with the buccal cusp partially or completed covered. Material and method: 2 3-D FEA models of a maxillary premolar were built from μCT data. All models were restored with a feldspathic laminate veneer using Solidworks. A similar tooth reduction (0.5mm) was applied for two models. The buccal cusp reduction of the premolar followed two configurations: Model (Mt) - buccal cusp completely covered by veneer; and Model (Mp) - buccal cusp partially covered by veneer. The loading (150N, in 45o) was performed on the buccal cusp of each premolar. Appropriate boundary condition was applied at the periodontal ligament surfaces and ANSYS (10.0) was used to obtain the maximum shear stress ( shear) and maximum principal stress ( max) for the laminate veneer and resin luting cement layer. Results: The Mp showed higher shear than Mt in 9 to 12 analyzed areas. The Mp showed smallest variation of max in laminate veneer (from -3,13 to 14,4 MPa) compared with Mt (from - 2,08 to 24,3 MPa). The resin luting cement showed similar variation of max between Mp and Mt (from -3.13 to 12.2 MPa) and (from -1.61 to 14.1 MPa), respectively. None of the structures exceeded the ultimate tensile strength or the shear bond strength to dentin and enamel. Conclusion: The laminate veneer and the resin luting cement layer showed an adequate behavior when veneer was applied in premolars. Cusp reduction did not affect significant increase in max and shear. In general, the Mp showed better behavior ( max) than Mt. The Mt showed better behavior ( shear) than Mp.
119

Efeito da troca iônica nos parâmetros de Weibull, de crescimento subcrítico de trincas e no comportamento de curva R de uma porcelana odontológica / Efffect of ion exchange on Weibull and slow crack growth parameters and R-curve behavior of a dental porcelain

Vinicius Rosa 06 July 2007 (has links)
O objetivo deste estudo foi avaliar o efeito da temperatura de troca iônica (TI) nas propriedades mecânicas da porcelana Ultrapaline ST e o efeito da TI nos parâmetros de crescimento subcrítico de trincas (SCG) (coeficiente de SCG - n, parâmetro escalar - ?f0), de Weibull (resistência característica - ?0, módulo de Weibull - m) e no comportamento de curva R desta porcelana. 250 discos (12 mm diâmetro x 1 mm espessura) foram fabricados de acordo com as instruções do fabricante, usinados em retificadora plana e polidos até 1 ?m. Para determinar o efeito da temperatura de TI na resistência à flexão biaxial (?), dureza (H) e tenacidade à fratura (KIc), 40 discos foram divididos em 4 grupos (n=10): GI (controle) - sem TI; e GII, GIII e GIV submetidos a TI com KNO3 por 15 min a 450°C; 470°C e 490°C, respectivamente. A ? foi determinada por \"pistão sobre três esferas\" em saliva artificial a 37°C a 10 MPa/s. Para dureza e tenacidade à fratura, foram feitas 3 indentações Vickers em cada espécime (2kg, 30s) e as diagonais e trincas radiais foram medidas e os valores de H e KIc calculados. As médias e desvios-padrão para ? (MPa), H (GPa) e KIc (MPa.m1/2) foram: GI: 57,95 ± 8.97, 7,24 ± 0,79 e 1,14 ± 0,14; GII: 125,04 ± 23,58, 5,80 ± 0,14, 2,62 ± 0,14; GIII: 133,00 ± 11,00, 5,88 ± 0,45, 2,54 ± 0,22; GIV: 137,67 ± 12,05, 5,88 ± 0,17, 2,57 ± 0,10, respectivamente. Para determinação dos parâmetros de SCG e de Weibull, 140 espécimes foram divididos em 2 grupos: GC (controle) e GT (submetidos à TI por 15 min a 470°C). Para determinação de n e de ?f0, 50 espécimes de cada grupo foram testados em saliva artificial a 37°C em flexão biaxial em uma das seguintes taxas de tensão: 10-2, 10-1, 100, 101 e 102 MPa/s. Para determinação dos parâmetros de Weibull, mais 20 espécimes de cada grupo foram ensaiados na taxa de 100 MPa/s. Os valores de n, ?f0, m e ?0 foram, respectivamente (valores entre parênteses representam intervalos de confiança de 95%): 24,1 ± 2,5; 58,1 ± 0,01; 13,8 (10,0 a 18,8) e 60,4 (62,2 a 58,5) para GC e 36,7 ± 7,3; 127,9 ± 0,01; 7,4 (5,3 a 10,1) e 136,8 (129,1 a 144,7) para GT. Para determinação do efeito da TI no curva R, 7 espécimes de cada grupo receberam uma indentação Vickers em uma das seguintes cargas de indentação (kg): 0,18; 0,32; 0,56; 1,0; 3,2. Após armazenados ao ar por 24 h os espécimes foram ensaiados a 10 MPa/s em saliva artificial a 37°C. Os parâmetros ?, ?, q foram, respectivamente: 62,57; 0,12 e 0,2857 para GC e 161,50; 0,34 e -0,0074 para GT. Os valores de k variaram de 0,371 a 0,515 para GC e de 1,240 a 0,804 para GT. Não houve diferença nas propriedades mecânicas entre as três temperaturas de TI testadas. A TI promoveu aumento significativo do valor de n, ?f0 e ?0, entretanto resultou em diminuição do valor de m e também suprimiu o comportamento de curva R, presente no material antes da realização da TI. / The objectives of this study were to determine the influence of different ion exchange (IE) temperatures on mechanical properties of a dental porcelain Ultrapaline ST and the effect of IE on slow crack growth (SCG) (coefficient of SCG - n, scale parameter - ?f0) and Weibull parameters (characteristic strength - ?0; Weibull modulus - m) and R-curve behavior of this porcelain. 250 specimens (12 mm diameter x 1 mm height) were fabricated according to the manufacturer\'s instructions, grounded with a surface-grinding device and polished up to 1?m. To determine the effect of IE temperature on biaxial flexural strength (?), hardness (H) and fracture toughness (KIc), 40 specimens were divided in four groups (n=10) as follow: GI - control (no ion exchange); GII, GIII and GIV submitted to IE with KNO3 for 15 min at 450°C; 470°C e 490°C, respectively. The ? was determined using a piston-on-three-balls device, in artificial saliva at 37°C and constant loading rate of 10 MPa/s. For hardness and fracture toughness, 3 Vickers indentations (2kg, 30s) were made on each specimen. The diagonals and radial cracks were measured in order to calculate H and KIc. Mean and standard deviations values of ? (MPa), H (GPa) and KIc (MPa.m1/2) were: I: 57.95 ± 8.97; 7.24 ± 0.79; 1.14 ± 0.14; II: 125.04 ± 23.58; 5.80 ± 0.14; 2.62 ± 0.14; III: 133.00 ± 11.00; 5.88 ± 0.45; 2.54 ± 0.22; IV: 137.67 ± 12.05; 5.88 ± 0.17; 2.57 ± 0.10, respectively. To determine the effect of IE on SCG and Weibull parameters, 140 specimens were divided in 2 groups: GC (control) and GIE (submitted to IE at 470°C for 15 min). To determine the SCG parameters, 10 specimens of each group were tested in biaxial flexural strength in each one of five constant stress rates: 10-2, 10-1, 100, 101 e 102 MPa/s. To determine the Weibull parameters, 20 specimens of each group were tested in the stress rate of 100 MPa/s. The n, ?f0, m and ?0 (values in parenthesis represent the confidence interval) were: 24.1 ± 2.5; 58.1 ± 0.01; 13.8 (10.0 to 18.8) and 60.4 (62.2 to 58.5) for GC and: 36.7 ± 7.3; 127.9 ± 0.01; 7.4 (5.3 to 10.1) and 136.8 (129.1 to 144.7) for GIE, respectively. To determine the effect of IE on R-curve behavior, 7 specimens of each group received a Vickers indentation in one of the following indentation loads (kg): 0.18; 0.32; 0.56; 1.0; 3.2. After stored on air for 24 h, the specimens were tested biaxial flexure strength in artificial saliva at 37°C in a stress rate of 10 MPa/s. The ?, ?, q parameters were, respectively: 62.57; 0.12 and 0.2857 for GC and 161.50; 0.34 and -0.0074 for GIE. The values of k varied from 0.371 to 0.515 for GC and from 0.34 to 0.0074 for GIE. There are no differences on mechanical properties among the three IE temperatures tested. The IE promoted significantly increase of n, ?f0 and ?0 however, decreased the m value and suppressed the R-curve behavior originally present on material before the IE.
120

Efeito de diferentes tratamentos ácidos na rugosidade superficial e na resistência de união da cerâmica de dissilicato de lítio / Effect of different acid treatments in the surface roughness and the bond strength of lithium disilicate ceramic

Sudré, João Paulo da Silva 06 May 2015 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2016-08-04T17:39:56Z No. of bitstreams: 1 joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-08-05T11:49:24Z (GMT) No. of bitstreams: 1 joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5) / Made available in DSpace on 2016-08-05T11:49:24Z (GMT). No. of bitstreams: 1 joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5) Previous issue date: 2015-05-06 / O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos ácidos, variação da concentração e do tempo de exposição aos ácidos, hidrofluorídrico (HF) e fosfórico (H3PO4), sobre a rugosidade superficial e resistência de união de uma cerâmica vítrea reforçada por dissilicato de lítio cimentada com um cimento resinoso autoadesivo. Cem pastilhas da cerâmica IPS e.max Press® medindo 2 x 7 mm foram divididas em dez grupos de acordo com o tratamento de superfície (n=10): G1, controle, ou seja, sem tratamento; G2, G3 e G4 condicionamento com HF 5% por 20, 40 e 60 segundos, respectivamente; G5, G6 e G7, condicionamento com HF 10% por 20, 40 e 60 segundos, respectivamente; G8, G9 e G10 condicionamento com HF a 10% por 20,40 e 60 segundos respectivamente e, posteriormente, condicionamento com ácido fosfórico 37% por 5 segundos. A análise da rugosidade superficial foi feita em microscópio ótico confocal. As pastilhas representativas de cada grupo foram selecionadas e metalizadas para análise da morfologia superficial em microscopia eletrônica de varredura e em microscópio de força atômica. Para a análise de resistência de união ao microcisalhamento, sobre as superfícies devidamente tratadas, foi aplicado o silano RelyX Ceramic Primer® e aguardou-se 1 minuto para que se realizasse a cimentação. Foram cimentados três cilindros em cada pastilha com o cimento resinoso RelyXTM U200, e fotopolimerizados por 60 segundos cada. Os corpos de prova foram armazenados em água deionizada a 37°C por 24 horas (n=30). Terminado esse tempo, os corpos de prova foram submetidos ao teste de microcisalhamento em uma máquina de ensaios universal Emic DL 2000® com velocidade de 1 mm/minuto até que ocorresse a fratura. Os valores médios de ambos os testes foram submetidos à análise estatística ANOVA dois fatores e as médias comparadas pelo teste de Tukey com 5% de significância. Todas as superfícies fraturadas foram levadas ao estereomicroscópio com aumento de 50 vezes para verificar o padrão de falha ocorrido e alguns corpos de prova após a fratura, foram aleatoriamente escolhidos para representar cada tipo de falha, foram metalizados e levados ao microscópio eletrônico de varredura para caracterização da superfície. A maior rugosidade superficial foi obtida pelo grupo G6 (2,05±0,107) sendo superior estatisticamente aos demais. Já a menor rugosidade foi obtida pelo grupo controle G1 (0,567±0,057) e inferior estatisticamente aos demais. Os grupos G7 (1,785±0,037); G3 (1,608±0,03); G10 (1,551±0,046); G9 (1,449±0,047); G5 (1,443±0,06); G4 (1,422±0,103); G8 (1,339±0,036) e G2 (1,283±0,059) apresentaram valores intermediários de rugosidade. Dentre estes grupos, o G3 (22.75±1.97MPa) foi o que apresentou a maior média de resistência da união com falhas do tipo mista. Por outro lado, o G1 (5.25±1.29MPa) apresentou o menor valor médio de resistência da união com predominância de falhas adesivas. Assim, conclui-se que a concentração do ácido e o tempo influenciaram na rugosidade superficial, sendo maior para o condicionamento com ácido HF a 10%. Para a resistência da união, o tempo de condicionamento e a interação deste com a concentração dos ácidos influenciou de forma significativa; sendo que o ácido HF de menor concentração, 5% por 40 segundos, foi o que apresentou maiores valores. / The objective of this study was to evaluate the effect of different acid treatments, the concentration variation and the time of exposure to hydrofluoric (HF) and phosphoric acids (H3PO4) on the surface roughness and bond strength of a glass-ceramic reinforced by cement lithium disilicate with a self-adhesive resin cement. One hundred tablets of the IPS e.max Press® ceramic measuring 2 x 7 mm were divided into ten groups according to the surface treatment (n = 10): G1, control, or untreated; G2, G3 and G4 etching with 5% hydrofluoric acid for 20, 40 and 60 seconds, respectively; G5, G6 and G7 etching with 10% hydrofluoric acid for 20, 40 and 60 seconds, respectively; G8, G9 and G10 etching with 10% hydrofluoric acid for 20, 40 and 60 seconds respectively, and subsequently etched with phosphoric acid at 37% for 5 seconds. Analysis of surface roughness was performed confocal optical microscope. Representative tablets of each group were selected and metallized for analysis of surface morphology in scanning electron microscopy and atomic force microscope. For the analysis of bond strength to microshear, on properly treated surfaces, the silane RelyX Ceramic Primer® was applied and waited up to 1 minute to the holding of the cementing. Three-cylinder in each tablet were cemented with resin cement RelyXTM U200, and light cured for 60 seconds. The specimens were stored in deionized water at 37C for 24 hours (n = 30). After this time, the specimens were submitted to microshear test in a universal testing machine Emic DL 2000® with speed of 1 mm/min until the fracture. The average values of both tests were submitted to ANOVA two factors and the means compared by Tukey test at 5% significance level. All fractured surfaces were taken to the stereomicroscope with 50X enlargement to verify the pattern of failure occurred and some specimens with significant fractures of each type of failure were metallized and taken to the scanning electron microscope for surface characterization. The increased surface roughness was obtained by the G6 group (2.05 ± 0.107 N) and statistically superior. Already the slightest roughness was obtained by G1 control group (0.567 ± 0.057) and statistically lower to others. The G7 (1.785 ± 0.037); G3 (1.608 ± 0.03); G10 (1.551 ± 0.046); G9 (1.449 ± 0.047); G5 (1.443 ± 0.06); G4 (1.422 ± 0.103); G8 (1.339 ± 0.036) and G2 (1.283 ± 0.059) showed intermediate roughness values. Among these groups, the G3 (22.75 ± 1.97 N) was presented the highest mean bond strength with failures of mixed type. Moreover, G1 (5.25 ± 1.29 N) had the lowest average value of the bond strength with a predominance of adhesive failures. Thus, it is concluded that the acid concentration and time influence the surface roughness, being greater for etching with 10% hydrofluoric acid. For the bond strength, the conditioning time and the interaction of this with the concentration of the acid had a significant influence; being that the hydrofluoric acid of lower concentration, 5% for 40 seconds, showed the highest values.

Page generated in 0.1624 seconds