• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 4
  • 1
  • Tagged with
  • 30
  • 22
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Cargador Portátil Ecológico MAX - E / MAX -E Eco Friendly Portable Charger

Acosta Valverde, Melanie Araceli, Andrade Mariños, Joan Ayrton, Linares Castillos, Diego Alonso, Ortiz Chamochumbi, Renzo, Vásquez Calderón, John Erick 31 July 2020 (has links)
El presente proyecto es un cargador solar ecológico que puede ser transportado en todo momento debido a su tamaño compacto y su poco peso de 150 gramos. Además, almacena la energía del sol y la luz led para luego cargar tu dispositivo en cualquier momento. Se desarrolla su viabilidad en base a una investigación realizada a hombres y mujeres de 18 a 39 años de los niveles socioeconómicos A, B y C. Por lo tanto, el análisis permite identificar a un grupo de personas que necesitan cargar su celular en momentos importantes durante el día pero que no encuentran lugar donde conectarlo o no tienen un cargador. Para validar la solución se utilizó un prototipo del producto el cual fue presentado al público y especialistas para que salga al mercado. Por último, se realizó un concierge para calcular la intención de compra del producto y proyectar sus estados financieros, los cuales, están respaldados por pertinentes desarrollos estratégicos que llevan a cabo un plan de negocio.
22

Sensoriamento proximal de solo para a quantificação de atributos químicos e físicos / Proximal soil sensing: quantification of physical and chemical soil attributes

Eitelwein, Mateus Tonini 18 August 2017 (has links)
O trabalho teve o objetivo de investigar técnicas de sensoriamento de solo e analisar o potencial de utilização das mesmas diretamente no campo. Quatro etapas distintas foram desenvolvidas para atender aos seguintes objetivos: a) comparar e avaliar o potencial de predição de atributos do solo de três espectrômetros portáteis (vis-NIR) em ambiente controlado; b) avaliar a predição em movimento de pH, P e K utilizando técnicas de sensoriamento óptico (reflectância vis-NIR) e eletroquímico (eletrodos íon-seletivos de pH e K) em uma área experimental com variabilidade induzida; c) montar e testar uma plataforma de campo com sensores elétricos, eletroquímicos e ópticos; d) avaliar o potencial de predição de textura do solo utilizando um equipamento portátil de espectroscopia de fluorescência de raios X. Na primeira etapa as leituras de reflectância espectral vis-NIR dos três equipamentos avaliados mostraram-se muito semelhantes, com coeficientes de correlação acima de 0,86 na faixa de 400 a 1800 nm. Quando comparados nesta região espectral os equipamentos produziram modelos de predição muito semelhantes, com leve superioridade para o sistema FieldSpec. Os modelos mostraram-se mais promissores para a predição da textura do solo em relação aos atributos químicos. Na segunda etapa as leituras de campo utilizando eletrodos íon-seletivos de pH e K apresentaram uma alta correlação com as análises de laboratório. As avaliações permitiram observar que condições de solo com baixa umidade prejudicam sensivelmente as leituras. Apesar da alta correlação, os valores de campo precisam ser corrigidos para a metodologia de laboratório desejada. Os modelos de predição de P, K e pH utilizando espectrometria vis-NIR no campo apresentaram baixa precisão. Os testes da Plataforma Multisensores de Solo (PMS) na terceira etapa demonstraram ser possível a utilização de sensores elétricos, eletroquímicos e ópticos em uma mesma plataforma. As leituras de condutividade elétrica aparente do solo (CEa) demonstraram que este parâmetro está relacionado com a textura, atuando como um indicador da variabilidade e possibilitando a identificação dos locais de transição de textura. O pH mensurado pela PMS exibiu correlações abaixo das verificadas na segunda etapa. No entanto, alguns resultados atípicos foram verificados, como a correlação maior entre pH em CaCl2 com a PMS do que em relação ao método em H2O. As leituras de reflectância vis-NIR utilizando a PMS apresentaram bons modelos de predição de areia e argila, permitindo a criação de mapas de alta resolução destes parâmetros. A espectroscopia de fluorescência de raios X portátil foi eficiente para estimar a textura do solo. Os teores de areia e argila foram estimados tanto por meio de regressões lineares simples como regressões múltiplas com valores de R2 acima de 0,60. O Fe total foi o principal elemento utilizado nesses modelos de regressão. / The objective of this work was to investigate soil sensing techniques and to analyze the potential for their use directly in the field. Four distinct steps were developed to meet the following objectives: a) to compare and evaluate the potential of predicting soil attributes with three portable spectrometers (vis-NIR) in a controlled environment; B) to evaluate the on-the-go prediction of pH, P and K using optical sensors (vis-NIR reflectance) and electrochemical techniques (ion-selective pH and K electrodes) in an experimental area with induced variability; C) assemble and test a field platform with electrical, electrochemical and optical sensors; D) to evaluate the potential of predicting soil texture using a portable X-ray fluorescence spectroscopy equipment. In the first step the vis-NIR spectral reflectance readings of the three equipments evaluated were very similar, with correlation coefficients above 0.86 in the 400 to 1800 nm range. When compared in this spectral region, the equipment produced very similar prediction models, with slight superiority for the FieldSpec system. The models showed to be more promising for the prediction of soil texture in relation to chemical attributes. In the second step the field readings using ion-selective pH and K electrodes presented a high correlation with the laboratory analyzes. The evaluations showed that soil conditions with low moisture significantly affect the readings. Despite the high correlation, the field values need to be corrected for the desired laboratory methodology. Prediction models of P, K and pH using field-vis-NIR spectrometry showed low precision. The tests of the Multisensors Soil Platform (MSP) in the third stage demonstrated that it is possible to use electric, electrochemical and optical sensors in the same platform. The electrical conductivity (EC) readings showed that this parameter was related with soil texture, acting as an indicator of variability and allowing the identification of texture transitions. The pH measured by MSP exhibited correlations below those verified in the second step. However, some atypical results were verified, such as the higher correlation between pH in CaCl2 and MSP than in H2O. The vis-NIR reflectance readings using the MSP resulted in good sand and clay prediction models, allowing the creation of high resolution maps of these parameters. Portable X-ray fluorescence spectroscopy was efficient for estimating soil texture. The sand and clay contents were estimated both by simple linear regressions and multiple regressions with R2 values above 0.60. Total Fe was the main element used in these regression models.
23

Personalização de programas de TV no contexto da TV digital portátil interativa

Gatto, Elaine Cecília 29 November 2010 (has links)
Made available in DSpace on 2016-06-02T19:05:49Z (GMT). No. of bitstreams: 1 3587.pdf: 2175854 bytes, checksum: fc0f86f0d9275b05bf85e6629788ee4e (MD5) Previous issue date: 2010-11-29 / Interactive Digital Television allows several services to be offered to users, in order to provide entertainment, e-learning and new mechanisms for social inclusion. Broadcasters and TV shoes may be created, which may gradually increase the amount of information to be displayed on the screen. As a result, users may experience discomfort and difficulties in finding information that really matters. In a portable environment, the user wants to make the most of his time when watching TV. Thus, investing too much time in searching for TV shows of interest is something undesirable. Recommender systems are used to minimize such shortcomings, help users with their searches for contents of interest and also to reduce the time spent on searches. This study focused on the development of a hybrid recommender system called BIPODiTVR, which is able to make recommendations from the observation of users behavior while watching television on the portable device. This system recommends TV shows through a collaborative and content-based filtering. The proposed system was evaluated by using metrics of acceptability of recommender systems applied to data provided by IBOPE, from six households for the period of fifteen days. / A Televisão Digital Interativa permite que diversos serviços sejam oferecidos aos usuários, possibilitando entretenimento, educação à distância e novos mecanismos para a inclusão social. Emissoras e programas de TV podem ser criados, o que pode aumentar gradativamente a quantidade de informação disponível a ser visualizada nas telas. Como consequência, os usuários podem ter dificuldades em encontrar as informações que realmente interessam. No ambiente portátil o usuário deseja aproveitar ao máximo o seu tempo de visualização de TV, ou seja, investir tempo demasiado para procurar programas de TV do seu interesse é algo indesejado. Os sistemas de recomendação permitem minimizar tais dificuldades, auxiliando os usuários na sua busca por conteúdos que sejam do seu interesse e também reduzindo o tempo gasto durante a busca. Este trabalho tem como foco o desenvolvimento de um sistema de recomendação híbrido, denominado BIPODiTVR, que é capaz de recomendar conteúdo adequado a partir da observação do comportamento do usuário durante o uso da televisão no seu dispositivo portátil. O sistema recomenda programas de TV aos usuários utilizando as técnicas de Filtragem Colaborativa e Filtragem Baseada em Conteúdo e foi avaliado a partir de métricas de aceitabilidade de sistemas de recomendação baseado em dados fornecidos pelo IBOPE de seis domicílios em um período de quinze dias.
24

Um microanalisador em fluxo batelada para determinação fotométrica de sulfitos em bebidas / A micro-flow-batch analyser for photometric determination of sulphites in beverages

Tavares, Márcio Rennan Santos 29 August 2014 (has links)
Made available in DSpace on 2015-05-14T13:21:42Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2308276 bytes, checksum: 30fe5bd9f0346db5777a9c5983218c0f (MD5) Previous issue date: 2014-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Sulfites are chemical additives major role in the beverage industry, however, the excessive use of these additives can cause disease and its limit is a maximum of 0,7 mg/kg of body weight per day SO2. This study proposes a micro-batch-flow analyser (μFBA) for photometric determination of sulphites in beverages. The μFBA was built from the commercial urethane-acrylate resin and polymerized exhibiting photo of ultra-violet radiation. The photometric method for the determination of sulfites in beverages based on the reaction of salts of sulfites in an acid medium with formaldehyde solution subsequently reacted with pararosaniline hydrochloride solution giving finally, a complex of violet color with maximum absorption at 565 nm. The linear model of the calibration curve was validated by ANOVA, residual plot and left by the F test model. The detection limit was 0,08 mg L-1 and the relative standard deviation less than 1,5% (n = 3). A test precision assessed by recovery test (96,8% to 102,6%) was performed. The μFBA is potentially useful as an alternative to sulfites photometric determinations as parameters of quality of beverage and yield of 240 samples per hour, producing low consumption of sample and reagents. The results obtained by the proposed μFBA compared to the conventional method, no statistically significant differences in applying paired with a confidence level of 95% t-test / Os sulfitos são aditivos químicos com grande atuação na indústria de bebidas, entretanto o uso desses aditivos em excesso podem causar patologias e seu limite encontra-se no máximo de 0,7 mg/kg de SO2 peso corpóreo por dia. Esse estudo propõe um microanalisador em fluxo batelada (μFBA) para determinação fotométrica de sulfitos em bebidas. A microcâmara do μFBA foi construído a partir da resina comercial uretana-acrilato e polimerizado em fotoexpositora de radiação ultra-violeta. O método fotométrico para determinação de sulfitos em bebidas baseou-se na reação dos sais de sulfitos, em meio ácido, com solução de formaldeído que posteriormente reagiu com a solução de cloridrato de pararosanilina originando, por fim, um complexo de cor violeta com absorção máxima em 565 nm. O modelo linear da curva analítica foi validada através da ANOVA, gráfico dos resíduos e teste F deixados pelo modelo. O limite de detecção foi de 0.08 mg L-1 e o desvio padrão relativo inferior a 1,5% (n = 3). Foi realizado um teste de precisão avaliada através do teste de recuperação (96,8% a 102,6%). O μFBA é potencialmente útil como uma alternativa para determinações fotométricas de sulfitos como parâmetros de qualidade de bebidas e rendimento de 240 amostras por hora, gerando baixo consumo de amostra e reagentes. Os resultados obtidos pelo μFBA proposto comparado ao método convencional, não apresentou diferenças estatisticamente significativas na aplicação do teste t pareado com nível de confiança de 95%
25

Sensoriamento proximal de solo para a quantificação de atributos químicos e físicos / Proximal soil sensing: quantification of physical and chemical soil attributes

Mateus Tonini Eitelwein 18 August 2017 (has links)
O trabalho teve o objetivo de investigar técnicas de sensoriamento de solo e analisar o potencial de utilização das mesmas diretamente no campo. Quatro etapas distintas foram desenvolvidas para atender aos seguintes objetivos: a) comparar e avaliar o potencial de predição de atributos do solo de três espectrômetros portáteis (vis-NIR) em ambiente controlado; b) avaliar a predição em movimento de pH, P e K utilizando técnicas de sensoriamento óptico (reflectância vis-NIR) e eletroquímico (eletrodos íon-seletivos de pH e K) em uma área experimental com variabilidade induzida; c) montar e testar uma plataforma de campo com sensores elétricos, eletroquímicos e ópticos; d) avaliar o potencial de predição de textura do solo utilizando um equipamento portátil de espectroscopia de fluorescência de raios X. Na primeira etapa as leituras de reflectância espectral vis-NIR dos três equipamentos avaliados mostraram-se muito semelhantes, com coeficientes de correlação acima de 0,86 na faixa de 400 a 1800 nm. Quando comparados nesta região espectral os equipamentos produziram modelos de predição muito semelhantes, com leve superioridade para o sistema FieldSpec. Os modelos mostraram-se mais promissores para a predição da textura do solo em relação aos atributos químicos. Na segunda etapa as leituras de campo utilizando eletrodos íon-seletivos de pH e K apresentaram uma alta correlação com as análises de laboratório. As avaliações permitiram observar que condições de solo com baixa umidade prejudicam sensivelmente as leituras. Apesar da alta correlação, os valores de campo precisam ser corrigidos para a metodologia de laboratório desejada. Os modelos de predição de P, K e pH utilizando espectrometria vis-NIR no campo apresentaram baixa precisão. Os testes da Plataforma Multisensores de Solo (PMS) na terceira etapa demonstraram ser possível a utilização de sensores elétricos, eletroquímicos e ópticos em uma mesma plataforma. As leituras de condutividade elétrica aparente do solo (CEa) demonstraram que este parâmetro está relacionado com a textura, atuando como um indicador da variabilidade e possibilitando a identificação dos locais de transição de textura. O pH mensurado pela PMS exibiu correlações abaixo das verificadas na segunda etapa. No entanto, alguns resultados atípicos foram verificados, como a correlação maior entre pH em CaCl2 com a PMS do que em relação ao método em H2O. As leituras de reflectância vis-NIR utilizando a PMS apresentaram bons modelos de predição de areia e argila, permitindo a criação de mapas de alta resolução destes parâmetros. A espectroscopia de fluorescência de raios X portátil foi eficiente para estimar a textura do solo. Os teores de areia e argila foram estimados tanto por meio de regressões lineares simples como regressões múltiplas com valores de R2 acima de 0,60. O Fe total foi o principal elemento utilizado nesses modelos de regressão. / The objective of this work was to investigate soil sensing techniques and to analyze the potential for their use directly in the field. Four distinct steps were developed to meet the following objectives: a) to compare and evaluate the potential of predicting soil attributes with three portable spectrometers (vis-NIR) in a controlled environment; B) to evaluate the on-the-go prediction of pH, P and K using optical sensors (vis-NIR reflectance) and electrochemical techniques (ion-selective pH and K electrodes) in an experimental area with induced variability; C) assemble and test a field platform with electrical, electrochemical and optical sensors; D) to evaluate the potential of predicting soil texture using a portable X-ray fluorescence spectroscopy equipment. In the first step the vis-NIR spectral reflectance readings of the three equipments evaluated were very similar, with correlation coefficients above 0.86 in the 400 to 1800 nm range. When compared in this spectral region, the equipment produced very similar prediction models, with slight superiority for the FieldSpec system. The models showed to be more promising for the prediction of soil texture in relation to chemical attributes. In the second step the field readings using ion-selective pH and K electrodes presented a high correlation with the laboratory analyzes. The evaluations showed that soil conditions with low moisture significantly affect the readings. Despite the high correlation, the field values need to be corrected for the desired laboratory methodology. Prediction models of P, K and pH using field-vis-NIR spectrometry showed low precision. The tests of the Multisensors Soil Platform (MSP) in the third stage demonstrated that it is possible to use electric, electrochemical and optical sensors in the same platform. The electrical conductivity (EC) readings showed that this parameter was related with soil texture, acting as an indicator of variability and allowing the identification of texture transitions. The pH measured by MSP exhibited correlations below those verified in the second step. However, some atypical results were verified, such as the higher correlation between pH in CaCl2 and MSP than in H2O. The vis-NIR reflectance readings using the MSP resulted in good sand and clay prediction models, allowing the creation of high resolution maps of these parameters. Portable X-ray fluorescence spectroscopy was efficient for estimating soil texture. The sand and clay contents were estimated both by simple linear regressions and multiple regressions with R2 values above 0.60. Total Fe was the main element used in these regression models.
26

Determinação de cobre, cromo e arsênio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescências de raios X / Cu, Cr and As determination in preserved woods, Eucaliptus ssp, by x-ray fluorescence spectrometries

Pereira Junior, Sergio Matias 08 December 2014 (has links)
O Brasil produz cerca de 2,2 milhões de metros cúbicos de madeira preservada para atender à demanda anual nos setores de transporte ferroviário, elétrico, rural e de construção civil. As espécies de madeiras mais usados são do eucalipto (Eucalyptus sp.) e pinus (Pinus sp.). A madeira preservada, utilizada para postes, dormentes, mourões e nas construções em madeira, deve estar em conformidade com as especificações exigidas pelas normas brasileiras quanto ao seu tratamento preservativo. No Brasil, os preservativos de madeira mais utilizados e regulamentados são CCA (arseniato de cobre cromatado) e o CCB (sal de cobre cromo e boro). As técnicas analíticas como espectrometria de absorção atómica de chama (FAAS) e espectrometria de emissão de plasma acoplado (ICPOES) e espectrometria de fluorescência de raios x (XRFS) são utilizadas para a avaliação desses processos. Neste trabalho, as amostras de madeira foram obtidas de árvores de eucalipto (Eucalyptus sp.), provenientes de áreas de plantação do estado de Minas Gerais, Brasil. Amostras de madeira de eucalipto foram submetidas a diferentes concentrações de solução de CCA, sob pressão, atingindo retenções de 3,9; 6,7; 9,1; 12,4 e 14,0 kg de CCA por m-³ de alburno. A partir dos blocos tratados foram obtidos amostras em forma de cilindros e serragem. A determinação de cobre, cromo e arsênio foi realizada pela espectrometria de fluorescência de raios X de energia dispersiva (EDXRF), espectrometria de fluorescência de raios X portátil (PXRF), FAAS e IAAN. Neste trabalho, foram avaliados métodos de análise, sensibilidade e precisão, exatidão das técnicas analíticas relacionadas. / Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined.
27

Determinação de cobre, cromo e arsênio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescências de raios X / Cu, Cr and As determination in preserved woods, Eucaliptus ssp, by x-ray fluorescence spectrometries

Sergio Matias Pereira Junior 08 December 2014 (has links)
O Brasil produz cerca de 2,2 milhões de metros cúbicos de madeira preservada para atender à demanda anual nos setores de transporte ferroviário, elétrico, rural e de construção civil. As espécies de madeiras mais usados são do eucalipto (Eucalyptus sp.) e pinus (Pinus sp.). A madeira preservada, utilizada para postes, dormentes, mourões e nas construções em madeira, deve estar em conformidade com as especificações exigidas pelas normas brasileiras quanto ao seu tratamento preservativo. No Brasil, os preservativos de madeira mais utilizados e regulamentados são CCA (arseniato de cobre cromatado) e o CCB (sal de cobre cromo e boro). As técnicas analíticas como espectrometria de absorção atómica de chama (FAAS) e espectrometria de emissão de plasma acoplado (ICPOES) e espectrometria de fluorescência de raios x (XRFS) são utilizadas para a avaliação desses processos. Neste trabalho, as amostras de madeira foram obtidas de árvores de eucalipto (Eucalyptus sp.), provenientes de áreas de plantação do estado de Minas Gerais, Brasil. Amostras de madeira de eucalipto foram submetidas a diferentes concentrações de solução de CCA, sob pressão, atingindo retenções de 3,9; 6,7; 9,1; 12,4 e 14,0 kg de CCA por m-³ de alburno. A partir dos blocos tratados foram obtidos amostras em forma de cilindros e serragem. A determinação de cobre, cromo e arsênio foi realizada pela espectrometria de fluorescência de raios X de energia dispersiva (EDXRF), espectrometria de fluorescência de raios X portátil (PXRF), FAAS e IAAN. Neste trabalho, foram avaliados métodos de análise, sensibilidade e precisão, exatidão das técnicas analíticas relacionadas. / Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined.
28

Validação de sistema portátil de monitorização respiratória para o diagnóstico de apneia obstrutiva do sono em pacientes com doença arterial coronariana / Validation of portable respiratory monitoring system for the diagnosis of obstructive sleep apnea in patients with coronary artery disease

Naury de Jesus Danzi Soares 22 February 2011 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é caracterizada por episódios repetidos de colapso parcial ou completo das vias aéreas superiores durante o sono, resultando em eventos respiratórios caracterizados por hipopneias ou apneias, respectivamente. Os eventos respiratórios podem resultar em fragmentação do sono, hipoxemia recorrente e geração de pressão intratorácica negativa. Todos esses mecanismos são potencialmente deletérios ao sistema cardiovascular. A AOS é comum entre pacientes com doença cardiovascular, porém ainda é pouco reconhecida. O padrão ouro para o diagnóstico da AOS é a Polissonografia (PSG) completa. O acesso a PSG completa é limitado, contribuindo para o subdiagnóstico da AOS. A poligrafia noturna de variáveis respiratórias (PGR) é um método simplificado, sendo uma alternativa promissora para o diagnóstico da AOS. No entanto, estudos de validação de PGR incluíram somente populações pré-selecionadas ou referidas para laboratórios de sono e excluíram pacientes com comorbidades significativas. Atualmente a Academia Americana de Medicina do sono reconhece o uso da PGR para o diagnóstico da AOS em pacientes com alta probabilidade pré-teste de AOS moderada a grave e em pacientes sem comorbidades significativas. Objetivo: Validar a PGR para o diagnóstico de AOS entre pacientes consecutivos avaliados para cirurgia de revascularização miocárdica, portanto, com Doença Arterial Coronariana (DAC). Avaliar a prevalência da AOS e a utilidade dos sintomas clínicos para o diagnóstico da AOS entre os pacientes com DAC. Métodos: Pacientes com indicação de revascularização do miocárdio foram avaliados através de exames clínicos e laboratoriais de rotina, escala de sonolência diurna (Epworth) e risco clínico de apneia do sono (questionário de Berlin), ecocardiograma, PSG e PGR. A PGR utilizada é classificada como tipo 3, com os seguintes canais: fluxo de ar, esforço respiratório, oximetria de pulso, frequência de pulso, ronco e sensor de posição, (Stardust II ®). Resultados: Foram estudados 70 pacientes consecutivos (76% do sexo masculino); idade (média DP) = 58 ± 7 anos, índice de massa corpórea (IMC) [mediana (25-75%)] = 27,6 (25,8-31,1) kg/m2. Vinte pacientes (29%) apresentaram fração de ejeção do ventrículo esquerdo (FEVE) 45%. A PSG da população revelou índice de apneia e hipopneia (IAH)= 2320 eventos/h. A prevalência de AOS com um IAH 5, 15 e 30 eventos/h foi de 87%, 54% e 27%, respectivamente. A sonolência diurna medida pela escala de Epworth e o risco clínico de AOS verificado pelo questionário de Berlin foram pobres preditores de AOS. A sensibilidade / especificidade da PGR para detectar AOS (IAH 5 eventos/h) e AOS grave (IAH 30 eventos/h) foram 0,92/0,67% e 0,42/0,92%, respectivamente. A média da diferença do IAH entre os dois métodos diagnósticos apresentada no Bland-Altman foi de + 5,3, indicando que os valores do IAH da PGR foram em média inferiores aos da PSG. O desvio padrão da diferença foi de 14,6 eventos/hora, apresentando uma considerável concordância entre o IAH da PSG e da PGR. Conclusão: Este estudo valida o uso da PGR para o diagnóstico da AOS em uma população de pacientes consecutivos, avaliados para revascularização do miocárdio, em quem a doença cardíaca é significativa. A prevalência de AOS entre pacientes com DAC é alta atingindo mais de 50% dessa população. No entanto, os sintomas clínicos, nessa população, não são preditores adequados de AOS. Em função da alta prevalência de AOS e baixa especificidade de sintomas clínicos, nossos dados sugerem que a PGR é um instrumento promissor para a avaliação de pacientes com DAC avaliados para cirurgia de revascularização do micárdio / Introduction: Obstructive sleep apnea (OSA) is characterized by repeated episodes of partial or complete collapse of the upper airway during sleep, resulting in respiratory events characterized by hypopnea or apnea, respectively. Respiratory events may result in sleep fragmentation, hypoxemia and recurrent generation of negative intrathoracic pressure. All these mechanisms are potentially harmful to the cardiovascular system. OSA is common among patients with cardiovascular disease, but is still poorly recognized. The gold standard for diagnosis of OSA is polysomnography (PSG). Access to full PSG is limited, contributing to the under diagnosis of OSA. The polygraph nocturnal of respiratory variables (PGR) is a simplified method, being a promising alternative for the diagnosis of OSA. However, validation studies of PGR only included populations pre-selected or referred to sleep laboratories and excluded patients with significant comorbidities. Currently the American Academy of Sleep Medicine recognizes the use of PGR for the diagnosis of OSA in patients with high pretest probability of moderate to severe OSA and in patients without significant comorbidities. Objective: Validate the PGR for the diagnosis of OSA among consecutive patients evaluated for coronary artery bypass grafting (CABG), therefore with Coronary Artery Disease (CAD). To assess the prevalence of OSA and to evaluate the usefulness of clinical symptoms for diagnosis of OSA among patients with CAD. Methods: Patients with indication of CABG were evaluated by clinical examination and routine laboratory, the scale of daytime sleepiness (Epworth) and clinical risk of sleep apnea (Berlin questionnaire), echocardiogram, PSG and PGR. The PGR use is classified as type 3, with the following channels: airflow, respiratory effort, pulse oximetry, pulse rate, snoring and position sensor, (Stardust II ®). Results: We studied 70 consecutive patients (76% male); age (mean SD) = 58 ± 7 years; body mass index (BMI), [median (25-75%)] = 27,6 (25,8 to 31,1) kg/m2. Twenty patients (29%) had left ventricular ejection fraction (LVEF) 45%. The PSG of population showed apnea-hypopnea index (AHI) = 23 20 events / h. The prevalence of OSA with an AHI 5, 15 and 30 events / h was 87%, 54% and 27%, respectively. Daytime sleepiness measured by Epworth Sleepiness Scale and the clinical risk of OSA verified by the Berlin questionnaire were poor predictors of OSA. The sensitivity and specificity to detect OSA (AHI 5 events / h) and severe OSA (AHI 30 / events) of the PGR were 0,92/0,67% and 0,42/0,92%, respectively. The average difference in AHI between the two diagnostic methods presented in Bland-Altman was + 5,3, indicating that the values of the AHI of the PGR were on average lower than the PSG. The standard deviation of the difference was 14,6 events / hour, presenting a considerable agreement between the AHI of PSG and the PGR. Conclusion: This study validates the use of PGR for the diagnosis of OSA in a population of consecutive patients evaluated for CABG, in whom heart disease is significant. The prevalence of OSA among patients with CAD is high reaching over 50% of this population. However, the clinical symptoms are not adequate predictors of OSA in this population. Due to the high prevalence of OSA and low specificity of clinical symptoms, our data suggest that the PGR is a promising tool for the assessment of CAD patients evaluated for surgery for the CABG
29

Validação de sistema portátil de monitorização respiratória para o diagnóstico de apneia obstrutiva do sono em pacientes com doença arterial coronariana / Validation of portable respiratory monitoring system for the diagnosis of obstructive sleep apnea in patients with coronary artery disease

Soares, Naury de Jesus Danzi 22 February 2011 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é caracterizada por episódios repetidos de colapso parcial ou completo das vias aéreas superiores durante o sono, resultando em eventos respiratórios caracterizados por hipopneias ou apneias, respectivamente. Os eventos respiratórios podem resultar em fragmentação do sono, hipoxemia recorrente e geração de pressão intratorácica negativa. Todos esses mecanismos são potencialmente deletérios ao sistema cardiovascular. A AOS é comum entre pacientes com doença cardiovascular, porém ainda é pouco reconhecida. O padrão ouro para o diagnóstico da AOS é a Polissonografia (PSG) completa. O acesso a PSG completa é limitado, contribuindo para o subdiagnóstico da AOS. A poligrafia noturna de variáveis respiratórias (PGR) é um método simplificado, sendo uma alternativa promissora para o diagnóstico da AOS. No entanto, estudos de validação de PGR incluíram somente populações pré-selecionadas ou referidas para laboratórios de sono e excluíram pacientes com comorbidades significativas. Atualmente a Academia Americana de Medicina do sono reconhece o uso da PGR para o diagnóstico da AOS em pacientes com alta probabilidade pré-teste de AOS moderada a grave e em pacientes sem comorbidades significativas. Objetivo: Validar a PGR para o diagnóstico de AOS entre pacientes consecutivos avaliados para cirurgia de revascularização miocárdica, portanto, com Doença Arterial Coronariana (DAC). Avaliar a prevalência da AOS e a utilidade dos sintomas clínicos para o diagnóstico da AOS entre os pacientes com DAC. Métodos: Pacientes com indicação de revascularização do miocárdio foram avaliados através de exames clínicos e laboratoriais de rotina, escala de sonolência diurna (Epworth) e risco clínico de apneia do sono (questionário de Berlin), ecocardiograma, PSG e PGR. A PGR utilizada é classificada como tipo 3, com os seguintes canais: fluxo de ar, esforço respiratório, oximetria de pulso, frequência de pulso, ronco e sensor de posição, (Stardust II ®). Resultados: Foram estudados 70 pacientes consecutivos (76% do sexo masculino); idade (média DP) = 58 ± 7 anos, índice de massa corpórea (IMC) [mediana (25-75%)] = 27,6 (25,8-31,1) kg/m2. Vinte pacientes (29%) apresentaram fração de ejeção do ventrículo esquerdo (FEVE) 45%. A PSG da população revelou índice de apneia e hipopneia (IAH)= 2320 eventos/h. A prevalência de AOS com um IAH 5, 15 e 30 eventos/h foi de 87%, 54% e 27%, respectivamente. A sonolência diurna medida pela escala de Epworth e o risco clínico de AOS verificado pelo questionário de Berlin foram pobres preditores de AOS. A sensibilidade / especificidade da PGR para detectar AOS (IAH 5 eventos/h) e AOS grave (IAH 30 eventos/h) foram 0,92/0,67% e 0,42/0,92%, respectivamente. A média da diferença do IAH entre os dois métodos diagnósticos apresentada no Bland-Altman foi de + 5,3, indicando que os valores do IAH da PGR foram em média inferiores aos da PSG. O desvio padrão da diferença foi de 14,6 eventos/hora, apresentando uma considerável concordância entre o IAH da PSG e da PGR. Conclusão: Este estudo valida o uso da PGR para o diagnóstico da AOS em uma população de pacientes consecutivos, avaliados para revascularização do miocárdio, em quem a doença cardíaca é significativa. A prevalência de AOS entre pacientes com DAC é alta atingindo mais de 50% dessa população. No entanto, os sintomas clínicos, nessa população, não são preditores adequados de AOS. Em função da alta prevalência de AOS e baixa especificidade de sintomas clínicos, nossos dados sugerem que a PGR é um instrumento promissor para a avaliação de pacientes com DAC avaliados para cirurgia de revascularização do micárdio / Introduction: Obstructive sleep apnea (OSA) is characterized by repeated episodes of partial or complete collapse of the upper airway during sleep, resulting in respiratory events characterized by hypopnea or apnea, respectively. Respiratory events may result in sleep fragmentation, hypoxemia and recurrent generation of negative intrathoracic pressure. All these mechanisms are potentially harmful to the cardiovascular system. OSA is common among patients with cardiovascular disease, but is still poorly recognized. The gold standard for diagnosis of OSA is polysomnography (PSG). Access to full PSG is limited, contributing to the under diagnosis of OSA. The polygraph nocturnal of respiratory variables (PGR) is a simplified method, being a promising alternative for the diagnosis of OSA. However, validation studies of PGR only included populations pre-selected or referred to sleep laboratories and excluded patients with significant comorbidities. Currently the American Academy of Sleep Medicine recognizes the use of PGR for the diagnosis of OSA in patients with high pretest probability of moderate to severe OSA and in patients without significant comorbidities. Objective: Validate the PGR for the diagnosis of OSA among consecutive patients evaluated for coronary artery bypass grafting (CABG), therefore with Coronary Artery Disease (CAD). To assess the prevalence of OSA and to evaluate the usefulness of clinical symptoms for diagnosis of OSA among patients with CAD. Methods: Patients with indication of CABG were evaluated by clinical examination and routine laboratory, the scale of daytime sleepiness (Epworth) and clinical risk of sleep apnea (Berlin questionnaire), echocardiogram, PSG and PGR. The PGR use is classified as type 3, with the following channels: airflow, respiratory effort, pulse oximetry, pulse rate, snoring and position sensor, (Stardust II ®). Results: We studied 70 consecutive patients (76% male); age (mean SD) = 58 ± 7 years; body mass index (BMI), [median (25-75%)] = 27,6 (25,8 to 31,1) kg/m2. Twenty patients (29%) had left ventricular ejection fraction (LVEF) 45%. The PSG of population showed apnea-hypopnea index (AHI) = 23 20 events / h. The prevalence of OSA with an AHI 5, 15 and 30 events / h was 87%, 54% and 27%, respectively. Daytime sleepiness measured by Epworth Sleepiness Scale and the clinical risk of OSA verified by the Berlin questionnaire were poor predictors of OSA. The sensitivity and specificity to detect OSA (AHI 5 events / h) and severe OSA (AHI 30 / events) of the PGR were 0,92/0,67% and 0,42/0,92%, respectively. The average difference in AHI between the two diagnostic methods presented in Bland-Altman was + 5,3, indicating that the values of the AHI of the PGR were on average lower than the PSG. The standard deviation of the difference was 14,6 events / hour, presenting a considerable agreement between the AHI of PSG and the PGR. Conclusion: This study validates the use of PGR for the diagnosis of OSA in a population of consecutive patients evaluated for CABG, in whom heart disease is significant. The prevalence of OSA among patients with CAD is high reaching over 50% of this population. However, the clinical symptoms are not adequate predictors of OSA in this population. Due to the high prevalence of OSA and low specificity of clinical symptoms, our data suggest that the PGR is a promising tool for the assessment of CAD patients evaluated for surgery for the CABG
30

ARTESÁNIKA

Mansilla Ramirez, Carlos Sebastian, Machuca Hurtado, Diego José Rodrigo, Váez Coral, Karla Valeria, Valdez Meza, Andrea Carolina, Espinoza Guanilo, Milagros Giovana 30 November 2020 (has links)
Artesánika nace de la idea de brindar una opción económica que responda a la necesidad de comodidad acentuada en esta coyuntura en la cual muchos trabajadores y estudiantes se vieron obligados a realizar sus labores desde casa, teniendo que adaptar su entorno a sus nuevas necesidades. Por otro lado, identificamos que las lap desk no solo ayudan a trabajar desde casa, sino que son un complemento perfecto para diversas actividades como leer desde la comodidad de sus camas, ver una película en sus laptops, pintar un cuadro, etc. Cabe resaltar que validamos estos usos con las entrevistas realizadas y proponemos seguir diversificando nuestro portafolio para continuar atendiendo nuevas necesidades. Debemos agregar también que nuestra idea de negocio no implica sólo concretar ventas, sino que nos basamos en la idea de apoyar la reactivación económica de los pequeños artesanos quienes también se vieron afectados por la coyuntura actual al no poder trabajar. De esta manera, Artesánika trabaja de la mano con los artesanos peruanos para crear un producto de calidad, 100% peruano, a un precio justo y al alcance de todos. Por el lado de nuestros clientes, nos aseguramos de brindarles un producto de calidad, que cuente con todos los detalles que ellos necesitan para realizar sus distintas labores, además diseñamos tres colores que se ajustan a sus variadas preferencias y continuamente nos seguiremos renovando para ofrecerles el mejor producto y servicio. Teniendo todo esto en cuenta, buscamos ser un medio por el cual podamos brindarle una solución a ambas partes, tanto para el cliente como para los productores, siendo el nexo que une ambas necesidades y poder juntos aportar a la reactivación económica de nuestro país. / Artesánika was born from the idea of providing a low-priced option that responds to the need for comfort accentuated at this conjuncture in which many workers and students were forced to carry out their work from home, having to adapt their house environment to their new needs. On the other hand, we identify that lapdesks not only help to work from home, but that they are a perfect complement to various activities such as reading, watching a movie, painting a picture, etc. We must also add that our business idea does not only focuses on sales, but is based on the idea of supporting the economic reactivation of small artisans who were also affected by the current situation. Therefore, Artesánika works hand in hand with Peruvian artisans to create a quality product, 100% Peruvian, at a fair price and within reach of everyone. On the side of our customers, we make sure to provide them with a quality product, that has all the details they need to perform their different tasks. We also designed three colors that fit the preferences of our clients and we will continually renew to offer them the best product and service. Taking all this into account, we seek to be a means by which we can provide a solution to both parties, both for the customer and for the artisans, being the nexus that unites both needs and to be able together to contribute to the economic reactivation of our country. / Trabajo de investigación

Page generated in 0.0458 seconds