• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 1
  • Tagged with
  • 13
  • 13
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Dimensiones tomográficas del maxilar en menores y mayores de edad para la instalación de mini implantes de expansión rápida, Trujillo, 2021-2022

Cardozo Muñoz, Alina Kimberly January 2023 (has links)
El propósito de la investigación fue comparar las dimensiones del maxilar superior entre menores y mayores de edad para la instalación de miniimplantes de expansión rápida maxilar. Material y método: El estudio fue descriptivo, retroprospectivo y observacional. Se utilizó tomografías computarizadas de haz cónico para la evaluación de 30 pacientes sistemáticamente sanos entre 7 a 56 años de edad (25.47 +/- 13.88), divididos en tres grupos de 10 tomografías de menores hasta 14 años (11.30 +/-2.45), 10 de 15 a 30 años (23.20 +/- 4.83) y 10 de 31 años a más (41.90 +/- 7.92). Se seleccionaron las regiones de premolares y molares, para la medición vertical del maxilar superior, tanto de tejido blando como duro sobre 10 diferentes sitios transversales separados por 1 mm, para realizar las mediciones en el plano coronal. Para comparar las medidas se utilizaron las pruebas Kruskal Wallis y U de Mann-Whitney. Resultados: Se encontró que no existen diferencias estadísticamente significativas entre los grupos estudiados. Las dimensiones del tejido óseo variaron entre 5.40 mm a nivel del segundo molar y 7.84 mm a nivel del primer premolar, y las de tejido blando entre 1 mm a nivel del segundo premolar y 2.72 mm a nivel del primer premolar. Conclusión: Las dimensiones del tejido óseo y blando del maxilar superior, en sentido vertical, para la instalación de miniimplantes, fueron similares en mayores y menores de edad.
12

Comparación in vitro de la precisión dimensional de dos técnicas de impresión

Céspedes Brea, Bárbara Alisson 26 June 2017 (has links)
Objetivo: Comparar in vitro la precisión dimensional de la silicona por condensación mediante la técnica de impresión de doble mezcla; de doble impresión con alivio del margen y doble impresión con alivio total. Materiales y métodos: Las muestras estuvieron conformadas por 42 impresiones utilizando silicona por condensación Putty- Spedeex de un modelo maestro de acero inoxidable, el cual presentó dos pilares homogéneos que simularon la preparación para una corona. Estas muestras se dividieron en 3 grupos según la técnica de impresión (doble mezcla, doble impresión con alivio del margen y doble impresión con alivio total). Para determinar la precisión dimensional de los modelos definitivos en comparación al modelo maestro, se realizaron 7 mediciones (MD1, MD2, VL1, VL2, AL1, AL2, DI) con una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Se realizaron las pruebas estadísticas Kruskal-Wallis y U de Mann-Whitney. Resultados: Se encontraron diferencias estadísticamente significativas (p˂0.001) en las medidas MD1, MD2, AL2 al comparar las 3 técnicas de impresión con el modelo maestro. La técnica de doble impresión con alivio total presentó una mayor cantidad de medidas (MD1, MD2, VL1, AL1, DI) que no mostraron diferencias estadísticamente significativas (p<0.005) en comparación al modelo maestro. Conclusiones: La técnica de doble impresión con alivio total presentó mayor precisión dimensional que las técnicas de doble mezcla y la técnica de doble impresión con alivio del margen utilizando silicona de condensación. / Objective: Compare in vitro the dimensional precision of the polivinil siloxano using the technique of impression of double mixture; double impression with margin relief and double impression with total relief. Materials and methods: The samples were composed of 42 impressions using Putty-Spedeex polivinil siloxano from a master stainless steel model, which presented two homogeneous pillars that simulated the preparation for a crown. These samples were divided into 3 groups according to the printing technique (double mix, double impression with margin relief and double impression with total relief). In order to determine the dimensional accuracy of the final models in comparison to the master model, 7 measurements (MD1, MD2, VL1, VL2, AL1, AL2, DI) were performed with a coordinated machine, Contura G2 model with contact scanning technology ZEISS. Statistical tests were performed Kruskal-Wallis and U of Mann-Whitney. Results: Statistically significant differences (p˂0.001) were found in measures MD1, MD2, AL2 when comparing the three printing techniques with the master model. The double impression technique with total relief presented a greater number of measures (MD1, MD2, VL1, AL1, DI) than did not show statistically significant differences (p <0.005) in comparison to the master model. Conclusions: The technique of double impression with total relief presented greater dimensional accuracy than the techniques of double mixing and the technique of double impression with relief of the margin using silicone of condensation.
13

Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.

Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1 celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5) Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.

Page generated in 0.0888 seconds