• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 25
  • 25
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Aperfeiçoamento e avaliação de um novo sistema de digestão assistida por aquecimento condutivo em frasco fechado para preparar amostras de carne "in natura" para análise elementar / Alan Lima Vieira.

Vieira, Alan Lima. January 2016 (has links)
Orientador: José Anchieta Gomes Neto / Co-orientador: Kelber dos Anjos de Miranda / Banca: Mirian Cristina dos Santos / Banca: Mario Henrique Gonzalez / Resumo: Estabelecer procedimentos simples, rápidos, eficientes e com preparo de amostras de baixo custo para determinar elementos em amostras de carne é um aspecto relevante para fins nutricionais e de saúde. Por esta razão, um sistema de digestão com aquecimento condutivo em frasco fechado (CHDS), foi avaliado recentemente para a decomposição de amostras "in natura" de músculo, fígado e rim (bovino, suíno e frango) visando a determinação de macronutrientes (Ca, Mg, Na, K, S e P), micronutrientes (Cu, Fe, Mn, Mo, Se e Zn) e contaminantes inorgânicos (As, Cd, Cr e Pb) por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) e espectrometria de massas com plasma acoplado indutivamente (ICP-MS). O aperfeiçoamento feito no CHDS foi planejado para melhorar a segurança, a praticidade e a robustez do sistema. Entre elas destaca-se a adaptação de um pistão a gás na tampa do gabinete de digestão; isolamento dos frascos no interior do gabinete de digestão; tampa de Teflon com sistema simples de alívio de pressão ao fim da decomposição sem manuseio do frasco. A precisão foi avaliada analisando três materiais de referência certificados digeridos pelo CHDS. As recuperações para Ca, Cu, Fe, Mg, Mn, Na, K, S, P e Zn determinados por ICP OES, variaram entre 85 a 106%. Para As, Cd, Cr, Mo, Pb e Se determinados por ICP-MS, foram obtidas recuperações entre 92 a 110%. A eficiência da digestão também foi avaliada pela determinação do teor de carbono residual, que variou de 10 a 12% m m -1 . Quando as amostras de carne foram digeridas usando o CHDS, os resultados para Ca, Cu, Fe, Mg, Mn, Na, K, S, P e Zn determinados por ICP OES e para As, Cd, Cr, Mo, Pb e Se determinados por ICP-MS foram concordantes com aqueles obtidos após digestão ácida assistida por radiação micro-ondas em frasco fechado (MW- AD). Ao utilizar o CHDS, os limites de quantificação foram... / Abstract: Establishing simple, fast, efficient and low-cost sample preparation procedures to determine elements in meat samples is a relevant aspect for nutritional and health purposes. For this reason, the recently proposed closed-vessel conductively- heated digestion system (CHDS) was evaluated for the decomposition of muscle, liver and kidney (cattle, pigs and chickens) samples fresh aiming for the determination of macronutrients (Ca, Mg, Na, K, S and P), micronutrients (Cu, Fe, Mn, Mo, Se and Zn) and inorganic contaminants (As, Cd, Cr and Pb) by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS). The optimization of the CHDS was planned to improve safety, practicality and robustness such as adaptation of a gas piston in the digestion cabinet cover, isolation of vessels inside the digestion cabinet and a Teflon cap with a simple pressure relief system in the end of the decomposition without handling the vessel. The accuracy was evaluated by analyzing three certified reference materials digested by the CHDS. Recoveries for Ca, Cu, Fe, Mg, Mn, Na, K, S, P and Zn determinations by ICP OES varied from 85 to 106%. For As, Cd, Cr, Mo, Pb and Se determinations by ICP-MS, recoveries within the 92-110% were obtained. The digestion efficiency was also evaluated by determining the residual carbon content, which varied from 10 to 12% m m -1 . When fresh meat samples were digested using the CHDS, results for Ca, Cu, Fe, Mg, Mn, Na, K, S, P and Zn determinations by ICP OES and for As, Cd, Cr, Mo, Pb and Se determinations by ICP-MS were in agreement with those obtained after closed-vessel microwave-acid digestion (MW-AD). When using the CHDS, limits of quantification were similar to those obtained with the MW-AD for all analytes. The CHDS enabled the digestion of 800 mg of fresh meat with 2 mL of HNO 3 and 1 ml of H 2 O 2 . The proposed procedure... / Mestre
22

\"Identificação de produtos de reação presentes em soluções resultantes de digestões ácidas de amostras agronômicas\" / Identification of reaction products in solutions produced by acid digestions in agronomic samples

Mario Henrique Gonzalez 01 March 2007 (has links)
Entre as diferentes formas empregadas para o preparo de amostras orgânicas visando a determinação de elementos inorgânicos, uma alternativa que foi avaliada neste trabalho foi a digestão assistida por radiação microondas empregando ácidos diluídos. Estudos recentes demonstram ser essa uma alternativa eficiente no tocante à solubilização de elementos minerais para determinação por técnicas espectroscópicas. No entanto, a eficiência deste procedimento depende das características originais da amostra. Neste enfoque, a eficiência da decomposição foi avaliada, considerando-se as características originais das amostras e a caracterização dos produtos finais presentes na solução após a decomposição. Amostras de tecido vegetal (soja em gãos e Paspalum) e de tecido animal (sangue e vísceras de bovino), utilizando misturas oxidantes em diferentes concentrações ácidas foram digeridas em forno por radiação microondas com cavidade. A eficiência das decomposições, avaliada a partir da determinação dos teores de carbono orgânico residual e da recuperação de minerais. A caracterização original das amostras, realizada a partir da determinação dos teores de proteína bruta (PB), gordura (EE), carbono original (CHN-S), efetuada com o intuito de correlacionar essas características com os compostos remanescentes após as digestões. As soluções residuais foram caracterizadas inicialmente por técnica espectroscópica (RMN de 1H) para identificar os principais compostos orgânicos remanescentes. Após os primeiros resultados, estudos para separação FORAM realizados por cromatografia líquida de alta eficiência com detecção por ultravioleta. Em seguida os produtos de reação foram, correlacionados com a composição química inicial das amostras. / Microwave-assisted with diluted acids is an alternative to sample preparation of organic samples owing inorganic elements solubilization for spectroscopic techniques determination. The efficiency of this procedure depends on the sample?s original characteristics. In this way, the decomposition efficiency was evaluated considering the sample?s original characteristics and the final products presents in the solution after decomposition. Grains of soybean and samples of forage, bovine blood, and bovine viscera were digested in cavity-microwave oven using oxidants mixtures in different acid concentrations. The decomposition efficiency was evaluated from residual organic carbon determination and mineral recovery by inductively coupled plasma optical emission spectrometry. The original sample characterization was performed from crude protein amount, fatty, and original carbon. In order to identify the main remaining organic compounds, the residual solutions were firstly characterized by spectroscopy technique (1H NMR), with the identification of typical nitro-, aliphatic- and aromatic- compounds. Studies concerning separation of nitrobenzoic acids isomers were performed by HPLC-UV, by using reversal phase chromatography with C18 as stationary phase and H2O:acetonitrile:methanol (75:20:5) + 0.05% TFA as mobile phase. The use of diluted acids proved to be useful and recommended alternative, reducing the reagents volume and consequently the variability of the residues provided by the decomposition process. Comparing the digested solutions with the original sample composition, biological matrix with structural amino acids, proteins and lipids produced nitrobenzoic acid isomers and other organic compounds provided from the cleavage in chemical bonds.
23

Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino / Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)

Juliana Andrade Nunes 07 August 2009 (has links)
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão. / The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.
24

Determinação de Al, Cr, Cu e Zn em amostras de cana-de-açúcar usando amostragem direta de suspensão e detecção por espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite (GF AAS)

Reis, Paola Ramos Coutinho 23 January 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-08T18:13:26Z No. of bitstreams: 1 paolaramoscoutinhoreis.pdf: 878626 bytes, checksum: 6f7c7b3e0e49cd06d6fc76cdb805a7eb (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-17T14:03:51Z (GMT) No. of bitstreams: 1 paolaramoscoutinhoreis.pdf: 878626 bytes, checksum: 6f7c7b3e0e49cd06d6fc76cdb805a7eb (MD5) / Made available in DSpace on 2017-05-17T14:03:51Z (GMT). No. of bitstreams: 1 paolaramoscoutinhoreis.pdf: 878626 bytes, checksum: 6f7c7b3e0e49cd06d6fc76cdb805a7eb (MD5) Previous issue date: 2014-01-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho são apresentados métodos desenvolvidos para determinação direta de Al, Cr, Cu e Zn em amostras de folha de cana-de-açúcar usando amostragem direta de suspensão e detecção por GF AAS. As amostras vegetais foram desidratadas e moídas em diferentes granulometrias (106 µm, 75 µm e 53 µm). Amostras com granulometria menor do que 53 µm associadas aos agentes estabilizantes ácido nítrico 5% v/v e a mistura ácido nítrico 5% v/v:Triton X-100 0,04% v/v foram as mais adequadas para o preparo das suspensões. A melhor estratégia para homogeneização da suspensão foi o borbulhamento com ar, porém, com interrupção no momento da amostragem (stop-flow). A otimização das condições experimentais para a determinação de Al, Cr, Cu e Zn por GF AAS incluiu estudos dos efeitos de matriz, utilização de modificadores químicos e a otimização das temperaturas de pirólise e atomização. Na determinação de Al e Cr foi utilizado o Mg(NO3)2 como modificador químico, enquanto que para o Zn foi usado o Pd como modificador, já para a determinação do Cu não foi necessário a utilização de modificador químico. As melhores temperaturas de pirólise e atomização obtidas foram 1700°C e 2400°C para Al; 1500°C e 2300°C para Cr; 1000°C e 2100°C para Cu e 1100°C e 2100°C para Zn. Os efeitos de matriz foram avaliados pela comparação dos dados obtidos com o método das adições de padrões e com a curva analítica em meio aquoso. A exatidão do procedimento proposto foi avaliada pela comparação com os dados obtidos usando a técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES). O método otimizado foi utilizado para análise direta de amostras em suspensão de folhas de cana-de-açúcar. As amostras apresentaram valores entre 6,03 a 56,70 µg g -1 para o Al; 23,95 a 472,79 µg g -1 para o Cr; 11,59 a 19,38 µg g -1 para o Cu e 15,14 a 26,44 µg g -1 para o Zn. Os resultados obtidos demonstraram que a análise direta de suspensões por espectrometria de absorção atômica em forno de grafite (GF AAS) apresenta-se como alternativa factível para estudos envolvendo o diagnóstico e correção de desequilíbrios nutricionais das plantas. / In this work developed methods for the direct determination of Al, Cr, Cu and Zn in leaf samples of sugarcane using slurry sampling and detection by GF AAS are presented. Leaf samples were dried and ground at different particle sizes (106 µm, 75 µm and 53 µm). Samples with granulometry smaller than 53 µm associated with the stabilizing agents nitric acid 5 % v/v and the mixture nitric acid 5% v/v:Triton X-100 0.04% v/v were the most suitable for the slurry preparation. The best strategy for slurry homogenization was the bubbling with air. However, this was stopped during the sampling step (stop-flow). The optimization of the experimental conditions for the determination of Al, Cr, Cu and Zn by GF AAS included studies of matrix effects, the use of chemical modifiers and optimization of the temperatures of pyrolysis and atomization. In the determination of Al and Cr, Mg(NO3)2 was used as chemical modifier, while for the Zn, Pd was used. The use of a chemical modifier for Cu determinations was not necessary. The best pyrolysis and atomization temperatures obtained were 1700°C and 2400°C for Al; 1500°C and 2300°C for Cr; 1000°C and 2100°C for Cu and 1100°C and 2100°C for Zn. The matrix effects were evaluated by comparing data obtained by using the method of standard additions and analytical curves in an aqueous medium. The accuracy of the procedure was evaluated by comparison with the data obtained using the technique of inductively coupled plasma optical emission spectrometry (ICP OES). The optimized method was used for direct analysis of a series of slurry samples of sugarcane leaves. Values between 6.03 to 56.70 µg g -1 for Al; 23.95 to 472.79 µg g -1 for Cr; 11.59 to 19.38 µg g -1 to Cu and 15.14 to 26.44 µg g -1 for Zn were found. The results demonstrate that the direct analysis of slurry samples by graphite furnace atomic absorption spectrometry (GF AAS) presents itself as a feasible alternative for studies involving the diagnosis and correction of nutritional imbalances of plants as sugarcane.
25

Estudo crítico de métodos de preparo de amostras de material particulado atmosférico para determinação de elementos-traço por espectrometria de absorção atômica

Mimura, Aparecida Maria Simões 23 March 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-09-05T19:34:04Z No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 7449936 bytes, checksum: 9387a1b14578312925e3a1279f2720d7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-09-06T11:35:45Z (GMT) No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 7449936 bytes, checksum: 9387a1b14578312925e3a1279f2720d7 (MD5) / Made available in DSpace on 2017-09-06T11:35:45Z (GMT). No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 7449936 bytes, checksum: 9387a1b14578312925e3a1279f2720d7 (MD5) Previous issue date: 2017-03-23 / Na atmosfera são encontradas partículas de sólidos ou líquidos que se encontram suspensas no ar, chamadas de particulados. O tamanho dessas partículas pode estar associado ao seu potencial para causar danos à saúde humana, uma vez que estas podem ficar retidas no trato respiratório, desencadeando diversas doenças. Na superfície do material particulado podem ser encontrados, entre diversos contaminantes, os elementos-traço. Neste contexto, o objetivo deste estudo foi desenvolver métodos analíticos para a extração de elementos-traço em amostras de material particulado atmosférico com posterior determinação destes elementos por espectrometria de absorção atômica. As amostras foram coletadas mensalmente na cidade de Juiz de Fora, MG, Brasil, num período de 24 meses, utilizando coletores passivos instalados em quatro pontos de coleta (em duas avenidas com intenso fluxo de veículos, em uma área industrial e em uma região com elevada altitude e menor tráfego de veículos). Os parâmetros instrumentais para a determinação de Al, As, Cd, Cr, Cu, Fe, Mn, Pb e Zn por espectrometria de absorção atômica com chama (F AAS) e espectrometria de absorção atômica com forno de grafite (GF AAS) foram investigados. Dois métodos de preparo de amostras de material particulado foram desenvolvidos, utilizando extração assistida por ultrassom e extração assistida por micro-ondas. Os métodos apresentaram resultados adequados referentes à precisão (RSD <10 %) e à exatidão (recuperações entre 83 e 114 %), tempo reduzido (10 min) no preparo das amostras e pequeno consumo de reagente (água régia: 5,0 mL). As amostras de material particulado (n = 92) foram preparadas com o método de extração assistida por micro-ondas utilizando água régia diluída, com posterior determinação dos analitos por F AAS e GF AAS. Utilizando o cálculo do fator de enriquecimento, a análise de componentes principais, a análise de agrupamentos hierárquicos e a matriz de correlação de Pearson, foram identificadas as possíveis fontes de cada analito em cada ponto. Os analitos Al, Fe, Cr e Mn foram relacionados a fontes naturais, como a ressuspensão de poeira do solo. No entanto, os analitos As, Cu, Cd, Pb e Zn podem estar associados a fontes antrópicas. Valores médios elevados foram obtidos para Cd, Pb e Zn (146, 2895, 40924 mg kg-1, respectivamente) no ponto 2, região com intensa atividade industrial. De modo geral, as possíveis fontes dos analitos nas amostras de material particulado estudadas são ressuspensão de poeira do solo, poluição industrial (metalurgia e siderurgia), queima de biomassa, construção civil e queima de combustíveis fósseis. / On the atmosphere, particles of solids or liquids are found, suspended in the air, known as particulate matter. The size of these particles may be associated with their harmful potential to human health, since they can be retained in the respiratory tract, causing several diseases. Several contaminants, such as trace elements, can be found on the surface of particulate matters. In this context, the aim of this study was to develop analytical methods for extraction of trace elements from atmospheric particulate matter samples with subsequent determination of these elements by atomic absorption spectrometry. The samples were collected, monthly, in the city of Juiz de Fora, MG, Brazil, during 24 months, using passive samplers, installed at four sampling sites (two avenues with large fleet of vehicles, an industrial area and a region with high altitude and small fleet of vehicles). Instrumental parameters for the determination of Al, As, Cd, Cr, Cu, Fe, Mn, Pb and Zn by flame atomic absorption spectrometry (F AAS) and graphite furnace atomic absorption spectrometry (GF AAS) were investigated. Two sample preparation methods for particulate matters were developed, using ultrasonic assisted extraction and microwave assisted extraction. The methods showed adequate results regarding precision (RSD <10 %) and accuracy (recoveries between 83 and 114 %), with reduced time (10 min) in sample preparation and low reagent consumption (aqua regia: 5.0 mL). Particulate matter samples (n = 92) were prepared with microwave assisted extraction using diluted aqua regia, with subsequent determination of the analytes by F AAS and GF AAS. Using enrichment factor, principal component analysis, hierarchical cluster analysis and Pearson correlation, the possible sources of each analyte at each point were identified. The analytes Al, Fe, Cr and Mn were related to natural sources, such as the resuspension of soil dust. However, the analytes As, Cu, Cd, Pb and Zn may be associated with anthropogenic sources. Critical mean values were obtained for Cd, Pb and Zn (146, 2895, 40924 mg kg-1, respectively) at site 2, a region with intense industrial activity. In general, the possible sources of the analytes in the studied particulate matter samples are resuspension of soil dust, industrial emission (metallurgy and steel mill), biomass burning, building construction and fossil fuel emissions.
26

Estratégias alternativas de preparo de amostras para a determinação de metais em alimentos por espectrometria de absorção atômica em chama

Brandão, Geovani Cardoso January 2011 (has links)
95 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-09-30T14:18:36Z No. of bitstreams: 1 Dissertação_Geovani.pdf: 923282 bytes, checksum: 410ba5c5697a7df386c4f1c432de6a27 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-09-30T14:20:24Z (GMT) No. of bitstreams: 1 Dissertação_Geovani.pdf: 923282 bytes, checksum: 410ba5c5697a7df386c4f1c432de6a27 (MD5) / Made available in DSpace on 2013-09-30T14:20:24Z (GMT). No. of bitstreams: 1 Dissertação_Geovani.pdf: 923282 bytes, checksum: 410ba5c5697a7df386c4f1c432de6a27 (MD5) Previous issue date: 2011 / CNPq / No presente trabalho, foram desenvolvidos métodos analíticos baseados em estratégias alternativas de preparo de amostras para a determinação de metais em alimentos por técnicas de espectrometria de absorção atômica com chama. No primeiro método, a amostragem de suspensão foi usada para o preparo de amostras de iogurte para a determinação de zinco por HR-CS FAAS. As condições experimentais estabelecidas para o preparo das suspensões foram: solução de HCl 2,0 mol L-1, tempo de sonicação de 20 min e uma massa de amostra de 1,0 g. Nestas condições, os limites de detecção e quantificação obtidos foram de 0,10 e 0,32 µg g-1, respectivamente. A precisão expressa como desvio padrão relativo (RSD) foi de 0,82 e 2,08% para amostras contendo concentrações de zinco de 4,85 e 2,49 µg g-1, respectivamente. A exatidão do método foi confirmada pela análise de material de referência certificado (CRM) de leite em pó desnatado NIST SRM 1549. O método proposto foi aplicado para determinação de zinco em sete amostras de iogurte. O teor de zinco variou de 2,19 a 4,85 µg g-1. No segundo método, a foto- oxidação com radiação UV e H2O2 foi usada para o preparo de amostras de vinho para a determinação de ferro e manganês por FS-FAAS. As condições experimentais estabelecidas para a degradação das amostras de vinho foram: volume de 2,5 mL de H2O2 30% (v/v), pH 10,0, concentração do tampão de 0,14 mol, L-1 e um tempo de irradiação de 30 min. Nestas condições, foram obtidos limites de detecção e quantificação de 0,030 e 0,099 µg mL-1 para ferro, e de 0,022 e 0,073 µg mL-1 para manganês, respectivamente. A precisão expressa como RSD foi de 2,8 e 0,65% para ferro, e de 2,7 e 0,54% para manganês para concentrações de 0,5 e 2,0 µg mL-1, respectivamente. Teste de adição e recuperação usado para avaliar a exatidão do método foi na faixa de 90 a 111% para ferro e na faixa de 95 a 107% para manganês. O método proposto foi aplicado para a determinação de ferro e manganês em seis amostras de vinho tinto. As concentrações obtidas variaram na faixa de 1,58 a 4,45 µg mL-1 para ferro e na faixa de 1,30 a 1,91 µg mL-1 para manganês. / Salvador
27

Contribuição para avaliação de influência do tratamento preliminar de amostra sobre a confiabilidade das informações analíticas

Santos, Wdson Costa January 2012 (has links)
68 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-05T17:50:29Z No. of bitstreams: 1 Dissertacao - Wdson Costa Santos.PDF: 1066509 bytes, checksum: 0409b0432c52d5bd01e90ebcf214766a (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-06-06T14:53:28Z (GMT) No. of bitstreams: 1 Dissertacao - Wdson Costa Santos.PDF: 1066509 bytes, checksum: 0409b0432c52d5bd01e90ebcf214766a (MD5) / Made available in DSpace on 2013-06-06T14:53:28Z (GMT). No. of bitstreams: 1 Dissertacao - Wdson Costa Santos.PDF: 1066509 bytes, checksum: 0409b0432c52d5bd01e90ebcf214766a (MD5) Previous issue date: 2012 / CAPES / No presente trabalho foram investigados os efeitos sobre a recuperação de elementos causados por modificações em processos prévios a amostragem laboratorial e lixiviação dos analitos das polpas de abóbora e batata. Inicialmente, foi avaliado o efeito da inversão na ordem de operações do procedimento de tratamento preliminar das amostras brutas das polpas sobre as recuperações dos elementos. As amostras das polpas foram secas para posterior trituração (PA) ou as amostras foram trituradas antes de serem submetidas à secagem (PB). Os resultados obtidos empregando ambos os procedimentos foram comparados para 95% de confiança e eles mostraram diferenças significativas para alguns elementos determinados na amostra de batata. As concentrações de K, P e Mn, na polpa de batata, determinadas aplicando o primeiro procedimento de pré-tratamento (PA) foram 13,6±0,4 mg K g-1, 1,95±0,04 mg P g-1 e 5,7±0,2 μg Mn g-1, enquanto 12,2±0,3 mg K g-1, 1,62±0,03 mg P g-1 e 2,6±0,2 μg Mn g-1 foram determinadas quando a mesma amostra bruta foi submetida ao pré-tratamento PB para a obtenção da amostra teste. Em contraposição, no caso da amostra bruta de polpa de abóbora, os resultados para os elementos (K, P, Mn, Mg) foram maiores quando a polpa foi previamente esmagada antes da secagem. Em um estudo independente, a eficiência da extração de metais de amostras de polpas trituradas de abóbora ou batata para soluções diluídas de HNO3 foi avaliada variando o modo (agitação mecânica ou irradiação ultrassônica) e o período (de 10 a 30 min) de agitação, bem como a concentração da solução de HNO3 na solução de lixiviação (de 0,7 a 2,1 mol L-1). Os resultados foram também comparados com aqueles obtidos nas digestões assistidas por micro-ondas das amostras teste v em meio nítrico-peróxido. Foi observado que para ambas as amostras teste (abóbora e batata) e independentemente do modo ou período de agitação que a eficiência de extração de Ca, K, Mg e Mn foi diminuída para solução para 2,1 mol L-1 HNO3. Uma melhora no nível de recuperação de P foi obtida quando a lixiviação foi realizada com soluções diluídas de HNO3 (0,7 e 1,4 mol L-1) e sob irradiação ultrassônica. Esse efeito foi relacionado à presença de átomos de fósforo em moléculas estruturais de células de abóbora e batata, bem como à cominuição (ou fragmentação) das partículas submetidas a um campo ultrassônico intenso. Contudo, efeitos indesejados foram também observados para alguns elementos quando submetidos às lixiviações assistidas com ultrassom, como exemplificado pelo teor de cálcio determinado após a lixiviação da amostra teste de batata ter atingido valor 2,3 vezes maior que o valor obtido após a mineralização da amostra em micro-ondas. Muitos desses efeitos foram relacionados à erosão da superfície interna frascos irradiados. / Salvador
28

Metodologia para o controle de qualidade e segurança do leite em relação à presença de contaminantes inorgânicos

Esteves, Wesley Tinoco 02 December 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-22T11:04:31Z No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T18:50:19Z (GMT) No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) / Made available in DSpace on 2016-01-25T18:50:19Z (GMT). No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) Previous issue date: 2014-12-02 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho buscou estabelecer um método para a determinação de contaminantes inorgânicos em leite cru que fosse compatível com aplicações em larga escala, como os programas regulatórios de monitoramento de contaminantes em leite. Para tal, foi proposta uma abordagem utilizando a técnica de espectrometria de emissão atômica em plasma (ICP-AES) sem mineralização das amostras, que foram solubilizadas em solução contendo etanolamina e ácido cítrico. Estudos foram conduzidos a fim de estabelecer condições instrumentais em que fosse possível utilizar o preparo amostral proposto mantendo o compromisso com a sensibilidade, exatidão e desempenho analítico necessários a fim de se atingir os limites de detecção requeridos por legislações relacionadas à segurança alimentar. A proporção ideal de diluição da amostra na solução de etanolamina e ácido cítrico foi de 1:2 (amostra:solução) e os valores mais adequados dos parâmetros instrumentais foram 1300W para a radiofrequência do plasma, 0,50L.min-1 para a vazão do gás auxiliar e 0,60L.min-1 para a vazão do gás de nebulização. Os limites de quantificação obtidos para Cd, Co, Cr, Cu e Pb foram, respectivamente, 6,54, 6,57, 14,8, 14,3 e 27,4 μg.mL-1. / This study aimed to establish a method for the determination of inorganic contaminants in raw milk that was compatible with largescale applications, such as regulatory programs for the monitoring of contaminants in milk. For this purpose, an approach using the technique of atomic emission spectrometry (ICP-AES) with no mineralization of the samples, which was solubilized in a solution containing ethanolamine and citric acid, has been proposed. Studies were conducted in order to establish experimental conditions in which it was possible to use the proposed sample preparation and keeping the commitment to sensitivity, accuracy and the analytical performance required by legislations related to food safety. The ideal ratio of sample dilution was 1:2 (sample:solution) and the most suitable values for instrumental parameters were 1300W for the plasma radiofrequency power, 0.50L.min-1 for the flow of auxiliary gas and 0.60L.min-1 for the flow of nebulizer gas. The quantification limits obtained for Cd, Co, Cr, Cu and Pb were, respectively, 6.54, 6.57, 14.8, 14.3 and 27.4 μg.mL-1.
29

Análise de pastilhas de plantas por espectrometria de emissão óptica com plasma induzido por laser em regimes temporais de nano- e de femtossegundos / Nanosecond and femtosecond laser-induced breakdown spectroscopy for the analysis of pellets of plant materials

Carvalho, Gabriel Gustinelli Arantes de 11 June 2015 (has links)
A influência das variáveis associadas ao laser como a fluência, o comprimento de onda, e a duração do pulso, assim como as relacionadas às propriedades das amostras, como a distribuição do tamanho das partículas e as características químicas da matriz, foram avaliadas visando à determinação quantitativa de macro- (P, K, Ca, Mg) e micronutrientes (Cu, Fe, Mn, Zn, B) em pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser (LIBS). Os efeitos da distribuição do tamanho das partículas e da fluência do laser foram investigados a partir da análise de amostras peneiradas (150-20 µm) empregando-se um sistema LIBS, em regime temporal de nanossegundos (ns-LIBS), montado com um laser de Nd:YAG a 1064 nm (pulsos de 5 ns e 360 mJ)e um espectrômetro com óptica Echelle e detector ICCD. Observou-se um aumento na sensibilidade e na precisão das medições com a diminuição do tamanho das partículas usadas no preparo das pastilhas, e uma diminuição dos efeitos de matriz causados por diferenças no tamanho das partículas, quando pastilhas preparadas com partículas < 75 µm foram analisadas com pulsos de 50 J cm-2. Verificou-se uma melhora significativa na exatidão das medições de Mg, Fe, Mn e Zn feitas em um conjunto de pastilhas de folhas de cana-de-açúcar (partículas < 75 µm) empregando-se esta fluência. Em uma segunda etapa, observou-se que variações no comprimento de onda do laser de Nd:YAG (1064, 532, 355 e 266 nm) não influenciaram de maneira significativa a precisão e exatidão das medições em pastilhas de folhas de cana-de-açúcar, obtendo-se correlações lineares entre as intensidades dos sinais de emissão e as correspondentes frações de massa dos analitos. Variações no comprimento de onda do laser de Nd:YAG não afetaram a análise de um conjunto heterogêneo de amostras, composto por pastilhas de folhas de plantas de diferentes espécies, como soja, cana-de-açúcar, milho, citros, café, por exemplo, por ns-LIBS. No entanto, diferentemente do observado para o conjunto de pastilhas de folhas de cana-de-açúcar, observou-se, uma baixa correlação (r cal < 0,90) entre as frações de massa de Ca, Mg, P, Cu, Fe, Mn e Zn determinadas por ns-LIBS e os valores de referência, o que demonstra a baixa robustez de ns-LIBS frente às variações na composição química das matrizes. Posteriormente, analisou-se este conjunto heterogêneo de amostras com sistema LIBS, em regime temporal de femtossegundos (fs-LIBS), montado com laser de Ti:Safira (pulsos de 60 fs e 1,65 mJ) e espectrômetro com óptica Czerny-Turner e ICCD. Demonstrou-se que o uso de pulsos em regime de fs proporcionou calibrações e validação menos dependentes da composição química das matrizes. As frações de massa de Ca, Mg, P, Fe e Mn previstas por fs-LIBS foram estatisticamente concordantes com os valores de referência, independentemente do modelo de calibração usado. Além disso, o uso de calibração multivariada melhorou a capacidade preditiva de ns-LIBS, assemelhando-se à de fs-LIBS. Concluiu-se que o emprego de fs-LIBS foi a estratégia mais robusta e que ofereceu maior flexibilidade à variabilidade matricial / The influence of laser properties, such as fluence, wavelength and pulse duration, as well as sample characteristics, such as particle size distribution and chemical matrix composition, was evaluated aiming at the quantitative determination of macro- (P, K, Ca, Mg) and micronutrients (Cu, Fe, Mn, Zn, B) in pellets of plant materials by laser-induced breakdown spectroscopy (LIBS). Firstly, the effects of particle size distribution and laser fluence on the analysis of pellets (test samples) prepared with sieved samples (from 150 to 20 µm apertures) were investigated. Experiments were carried out with a nanosecond LIBS (ns-LIBS) system by using a Q-switched Nd:YAG laser at 1064 nm (5 ns; 360 mJ) and a spectrometer with Echelle optics and intensified charge-coupled device (ICCD) detector. Results indicated that smaller particles yielded to sensitivities\' enhancement and attained better measurements\' precision. Moreover, matrix effects were reduced by analyzing pellets prepared from < 75 ?m sieved fractions and pulses of 50 J cm-2. In addition, there was a significant improvement on accuracy of Mg, Fe, Mn and Zn measurements in a set of test samples of sugarcane leaves by using this fluence. In a second experiment, variations in the Nd:YAG laser wavelength (1064, 532, 355 and 266 nm) did not affect the analysis of test samples of sugarcane leaves, and provided linear correlations between emission signal intensities and corresponding analytes mass fractions. In addition, variations within Nd:YAG laser wavelength did not affect the analysis of a heterogeneous sample set composed by pellets of leaves from different crops, such as soy, sugarcane, maize, citrus and coffee by ns-LIBS. However, in contrast to previous findings, the univariate calibration models for ns-LIBS presented lower linearity (r cal < 0.90) for Ca, Mg, P, Cu, Fe, Mn and Zn, no matter the laser wavelength used for the analysis. These circumstances reflect the low robustness of ns-LIBS to variations within matrix chemical composition among test samples. Afterwards, test samples from different crops were analyzed by a femtosecond LIBS (fs-LIBS) by using a Ti:Sapphire laser, including a mode-locked oscillator and an ultrafast amplifier (60 fs; 1.65 mJ per pulse), and a spectrometer with Czerny-Turner optics and ICCD. Findings indicated that the pulse duration was a decisive variable for providing accurate quantification of nutrients in different plant species, which present substantial differences in terms of matrix chemical composition. Close agreement between Ca, Mg, P, Fe and Mn mass fractions predicted by fs-LIBS and those determined by ICP OES was evidenced, whatever the modeling approach used. Contrarily, for ns-LIBS analysis of test samples from different crops, only the use of multivariate partial least squares (PLS) regression appears capable for resolving the non-linear transformations of the emission intensities according to the physical mechanisms governing this temporal regime of ablation. Thus, when using multivariate modeling, the figures-of merit reflecting the predictive capabilities of ns-LIBS resemble to those achieved by fs-LIBS. Either way, fs-LIBS is a more robust approach that better offers larger flexibility to the matrix variability
30

Análise de pastilhas de plantas por espectrometria de emissão óptica com plasma induzido por laser em regimes temporais de nano- e de femtossegundos / Nanosecond and femtosecond laser-induced breakdown spectroscopy for the analysis of pellets of plant materials

Gabriel Gustinelli Arantes de Carvalho 11 June 2015 (has links)
A influência das variáveis associadas ao laser como a fluência, o comprimento de onda, e a duração do pulso, assim como as relacionadas às propriedades das amostras, como a distribuição do tamanho das partículas e as características químicas da matriz, foram avaliadas visando à determinação quantitativa de macro- (P, K, Ca, Mg) e micronutrientes (Cu, Fe, Mn, Zn, B) em pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser (LIBS). Os efeitos da distribuição do tamanho das partículas e da fluência do laser foram investigados a partir da análise de amostras peneiradas (150-20 µm) empregando-se um sistema LIBS, em regime temporal de nanossegundos (ns-LIBS), montado com um laser de Nd:YAG a 1064 nm (pulsos de 5 ns e 360 mJ)e um espectrômetro com óptica Echelle e detector ICCD. Observou-se um aumento na sensibilidade e na precisão das medições com a diminuição do tamanho das partículas usadas no preparo das pastilhas, e uma diminuição dos efeitos de matriz causados por diferenças no tamanho das partículas, quando pastilhas preparadas com partículas < 75 µm foram analisadas com pulsos de 50 J cm-2. Verificou-se uma melhora significativa na exatidão das medições de Mg, Fe, Mn e Zn feitas em um conjunto de pastilhas de folhas de cana-de-açúcar (partículas < 75 µm) empregando-se esta fluência. Em uma segunda etapa, observou-se que variações no comprimento de onda do laser de Nd:YAG (1064, 532, 355 e 266 nm) não influenciaram de maneira significativa a precisão e exatidão das medições em pastilhas de folhas de cana-de-açúcar, obtendo-se correlações lineares entre as intensidades dos sinais de emissão e as correspondentes frações de massa dos analitos. Variações no comprimento de onda do laser de Nd:YAG não afetaram a análise de um conjunto heterogêneo de amostras, composto por pastilhas de folhas de plantas de diferentes espécies, como soja, cana-de-açúcar, milho, citros, café, por exemplo, por ns-LIBS. No entanto, diferentemente do observado para o conjunto de pastilhas de folhas de cana-de-açúcar, observou-se, uma baixa correlação (r cal < 0,90) entre as frações de massa de Ca, Mg, P, Cu, Fe, Mn e Zn determinadas por ns-LIBS e os valores de referência, o que demonstra a baixa robustez de ns-LIBS frente às variações na composição química das matrizes. Posteriormente, analisou-se este conjunto heterogêneo de amostras com sistema LIBS, em regime temporal de femtossegundos (fs-LIBS), montado com laser de Ti:Safira (pulsos de 60 fs e 1,65 mJ) e espectrômetro com óptica Czerny-Turner e ICCD. Demonstrou-se que o uso de pulsos em regime de fs proporcionou calibrações e validação menos dependentes da composição química das matrizes. As frações de massa de Ca, Mg, P, Fe e Mn previstas por fs-LIBS foram estatisticamente concordantes com os valores de referência, independentemente do modelo de calibração usado. Além disso, o uso de calibração multivariada melhorou a capacidade preditiva de ns-LIBS, assemelhando-se à de fs-LIBS. Concluiu-se que o emprego de fs-LIBS foi a estratégia mais robusta e que ofereceu maior flexibilidade à variabilidade matricial / The influence of laser properties, such as fluence, wavelength and pulse duration, as well as sample characteristics, such as particle size distribution and chemical matrix composition, was evaluated aiming at the quantitative determination of macro- (P, K, Ca, Mg) and micronutrients (Cu, Fe, Mn, Zn, B) in pellets of plant materials by laser-induced breakdown spectroscopy (LIBS). Firstly, the effects of particle size distribution and laser fluence on the analysis of pellets (test samples) prepared with sieved samples (from 150 to 20 µm apertures) were investigated. Experiments were carried out with a nanosecond LIBS (ns-LIBS) system by using a Q-switched Nd:YAG laser at 1064 nm (5 ns; 360 mJ) and a spectrometer with Echelle optics and intensified charge-coupled device (ICCD) detector. Results indicated that smaller particles yielded to sensitivities\' enhancement and attained better measurements\' precision. Moreover, matrix effects were reduced by analyzing pellets prepared from < 75 ?m sieved fractions and pulses of 50 J cm-2. In addition, there was a significant improvement on accuracy of Mg, Fe, Mn and Zn measurements in a set of test samples of sugarcane leaves by using this fluence. In a second experiment, variations in the Nd:YAG laser wavelength (1064, 532, 355 and 266 nm) did not affect the analysis of test samples of sugarcane leaves, and provided linear correlations between emission signal intensities and corresponding analytes mass fractions. In addition, variations within Nd:YAG laser wavelength did not affect the analysis of a heterogeneous sample set composed by pellets of leaves from different crops, such as soy, sugarcane, maize, citrus and coffee by ns-LIBS. However, in contrast to previous findings, the univariate calibration models for ns-LIBS presented lower linearity (r cal < 0.90) for Ca, Mg, P, Cu, Fe, Mn and Zn, no matter the laser wavelength used for the analysis. These circumstances reflect the low robustness of ns-LIBS to variations within matrix chemical composition among test samples. Afterwards, test samples from different crops were analyzed by a femtosecond LIBS (fs-LIBS) by using a Ti:Sapphire laser, including a mode-locked oscillator and an ultrafast amplifier (60 fs; 1.65 mJ per pulse), and a spectrometer with Czerny-Turner optics and ICCD. Findings indicated that the pulse duration was a decisive variable for providing accurate quantification of nutrients in different plant species, which present substantial differences in terms of matrix chemical composition. Close agreement between Ca, Mg, P, Fe and Mn mass fractions predicted by fs-LIBS and those determined by ICP OES was evidenced, whatever the modeling approach used. Contrarily, for ns-LIBS analysis of test samples from different crops, only the use of multivariate partial least squares (PLS) regression appears capable for resolving the non-linear transformations of the emission intensities according to the physical mechanisms governing this temporal regime of ablation. Thus, when using multivariate modeling, the figures-of merit reflecting the predictive capabilities of ns-LIBS resemble to those achieved by fs-LIBS. Either way, fs-LIBS is a more robust approach that better offers larger flexibility to the matrix variability

Page generated in 0.0557 seconds