• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 677
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 683
  • 412
  • 288
  • 208
  • 118
  • 96
  • 89
  • 72
  • 60
  • 56
  • 54
  • 49
  • 48
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Investigações na construção de imagens / Investigations on building images

Sanovicz, Monica Soares Tinoco [UNESP] 23 February 2016 (has links)
Submitted by MONICA SOARES TINOCO SANOVICZ null (monicatinocos@gmail.com) on 2016-04-19T17:24:03Z No. of bitstreams: 1 Monica Tinoco Investigações na Construção de Imagens.pdf: 1386884 bytes, checksum: e70be6203a3158630dd922fc9d963867 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-20T20:47:04Z (GMT) No. of bitstreams: 1 sanovicz_mst_me_ia.pdf: 1386884 bytes, checksum: e70be6203a3158630dd922fc9d963867 (MD5) / Made available in DSpace on 2016-04-20T20:47:04Z (GMT). No. of bitstreams: 1 sanovicz_mst_me_ia.pdf: 1386884 bytes, checksum: e70be6203a3158630dd922fc9d963867 (MD5) Previous issue date: 2016-02-23 / A dissertação descreve as concepções, os princípios e os procedimentos que utilizei em minha produção dos últimos 10 anos. Essa investigação procura apontar o caráter específico dos meios utilizados, tais como a fotografia, a pintura e mais recentemente, as produções têxteis bi e tri dimensionais. A pesquisa permitiu também a identificação de algumas relações entre o meu repertório pessoal e as diversas dimensões espaço temporais articuladas pelos meios de representação / The dissertation describes the concepts, principles and procedures that I used in my production over the last 10 years. This research tries to point out the specific character of the means used, such as photography, painting and more recently, two and three dimensional textile productions. The research also allowed the identification of some relations between my personal repertoire and several temporal spatial dimensions articulated by those means of representation
182

AVALIAÇÃO DO TORQUE DE FRATURA DE MINI-IMPLANTES SUBMETIDOS À ATÉ TRÊS REUTILIZAÇÕES / STUDY OF THE EFFECTS OF STERILIZATION AND REUSE OF MINI-SCREWS, UP TO THREE TIMES, ON TORQUE REQUIRED TO FRACTURE

Miotti, Fabrício Lamberti 29 July 2016 (has links)
Orthodontists have been reusing mini-implants that fail after installation or that will be inserted in a new place due to mechanic needs in order to optimize clinical time. The aim of this study was to simulate the reuse of mini-implants up to three times and evaluate their potential weakness. We used 48 screws (Morelli, Sorocaba, Brazil), which were divided into four groups: C= Control, G1 = one reuse, G2 = two reuse, G3 = three reuse. In order to simulate inserts in patients mouths, we used pig iliac bone. After we insert screws on bone specimen, we removed, cleaned, and sterilized them by autoclaving. The guide at the machine we used allowed us to standardize installations. After all groups were submitted to their reuse periods, mini-implants were submitted to fracture, and the strongest force necessary to break them was measured by a digital axial torquemeter. We used bovine tibia specimens for fracture, because of its greater bone cortical and bone density. We used One Way ANOVA (Bonferroni post-hoc) to compare means of each group. Results showed differences statistically significant between G3 and the other groups. All mini-implants needed strength higher than recommended by the literature to be inserted into patients, even though we found differences in fracture resistance between groups. / Na busca por não perder tempo clínico, ortodontistas vêm reutilizando mini-implantes que falham após a instalação ou que serão instalados em novo local devido à necessidades mecânicas. O objetivo deste estudo foi simular a reutilização de miniimplantes em até três vezes e avaliar a possível fragilização dos mesmos. Para isso, foram utilizados 48 parafusos (Morelli Sorocaba-SP, Brasil), os quais foram divididos em quatro grupos: C = Controle, G1 = uma reutilização, G2 = duas reutilizações e G3 = três reutilizações. Para simular, laboratorialmente, as instalações em boca nos pacientes, foi utilizado osso ilíaco suíno. Após serem inseridos no espécime de osso, os parafusos foram removidos, limpos e esterilizados em autoclave. Com um guia presente na máquina utilizada foi possível padronizar as instalações. Após todos os grupos passarem pelos ciclos de reutilização correspondentes, os mini-implantes foram submetidos à fratura, e a força máxima necessária para a quebra foi medida através de um torquímetro digital axial. Para a fratura, foram utilizados espécimes de tíbia bovina, por possuir maior densidade óssea e espessura de cortical. Os valores médios dos grupos foram analisados pela ANOVA de 1 fator com post-hoc em Bonferroni. Foram encontradas diferenças estatisticamente significativas entre o grupo G3 e os demais grupos. Mesmo com as diferenças na resistência à fratura entre os grupos, todos necessitaram de forças superiores às recomendadas para instalação em pacientes.
183

Stravinsky neoclássico: uma análise dos procedimentos composicionais

Vazzoler, Luciano Ferrara [UNESP] January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2008Bitstream added on 2014-06-13T20:55:17Z : No. of bitstreams: 1 vazzoler_lf_me_ia.pdf: 661466 bytes, checksum: e1ad82c415da1b637531008c17b8ae99 (MD5) / Nesta pequisa estuda-se a fase neoclássica do compositor Igor Stravinsky, identificando procedimentos composicionais específicos presentes em tal fase do compositor russo. Tais procedimentos estão estreitamente conectados com modelos referenciais da música da tradição tonal e apontam para interessante e pertinente diálogo entre contextos musicais bastante contrastantes. O objetivo desta dissertação, a partir da constatação de possíveis relações entre a fase neoclássica e a fase russa de Stravinsky, é discutir e analisar os procedimentos técnicos composicionais presentes na música da fase neoclássica. Para identificar tais procedimentos serão analisadas duas peças neoclássicas de Stravinsky: a Sonata para piano (1924) e o Capriccio para piano e Orquestra (1929). / This research is a study of Stravinsky´s neoclassical period in order to identify specific compositional procedures. These procedures are closely connected with models of tonal reference and point to an interesting dialogue through contrasting musicals contexts. The objective of this dissertation is to investigate possible relationships between the neoclassical and the russian period of Stravinsky's music, discussing mainly the technical procedures found in the neoclassical phase. To identify these procedures it will be analyzed two pieces of Stravinsky: Sonata for piano (1924) and Capriccio for piano and Orchestra (1929).
184

Utilização do SinpeC como ferramenta para comparação dos acessos cirúrgicos ao terço médio da face

Maniglia, Mauricio Pereira 19 November 2012 (has links)
Resumo
185

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores: estudo prospectivo

Arantes, Flávia de Moraes [UNESP] 29 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-29Bitstream added on 2014-06-13T21:05:59Z : No. of bitstreams: 1 arantes_fm_dr_araca.pdf: 917045 bytes, checksum: 35b80ca88f794114ea01fe8fe638b23f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba – UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste “t” pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste “t” de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... / The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba – UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages “Beginning” and “After”, a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student’s t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below)
186

Avaliação das demandas física e mental no trabalho do cirurgião em procedimentos eletivos

Diniz, Raimundo Lopes January 2003 (has links)
Esta tese aborda o trabalho de cirurgiões de um hospital de Porto Alegre, RS, durante procedimentos eletivos de pequeno, médio e grande porte, visando o estudo das possíveis relações entre as demandas física e mental e a idade e a experiência do cirurgião. Inicialmente, foi feito um mapeamento de constrangimentos ergonômicos relacionados ao trabalho cirúrgico e, num segundo momento: i) o nível de demanda física imposta aos cirurgiões eletivos por meio de uma técnica de avaliação de posturas (REBA – Rapid Entire Body Assessment) (HIGNETT & McATAMNEY, 2000), da Freqüência Cardíaca (FC), da Pressão Arterial (PA) (sistólica e diastólica) e do nível de hormonal (Noradrenalina) e; ii) o nível de demanda mental envolvida no trabalho por meio do nível hormonal (cortisol, Adenocorticotrófico – ACTH e Adrenalina e, também, por meio da FC e PA). De maneira geral, ficou evidente que, independentemente do tipo de cirurgia, há a presença de carga física de pouca intensidade e de carga mental de média intensidade entre os cirurgiões. Os resultados apontaram, também, que os cirurgiões mais jovens (menos experientes) apresentam mais esforço mental do que físico, principalmente nas cirurgias de grande porte, e os mais experientes têm mais esforço físico nas cirurgias de pequeno porte e menos esforço mental, em comparação aos mais jovens (menos experientes), nas cirurgias de grande porte. / This research has as its main objective to evaluate the relationships between both physical and mental workloads and age and experience related to surgeon’s work. The data collection was conducted at a hospital in Porto Alegre, State of RS, during elective surgeries of low, moderate and high levels of complexity. At first, a survey of ergonomics constraints related to surgical work was carried out. The objected were: i) to investigate the physical demand level by means of posture assessment technique (REBA – Rapid Entire Body Assessment) (HIGNETT & McATAMNEY, 2000), Heart Rate (HR), Blood Pressure (BP) (systolic and dyastolic) and cathecolamines (Noradrenaline); ii) to investigate the mental demand level through assessment of hormonal levels (cortisol, adenocorticotrophic - ACTH and cathecolamines – adrenaline) as well as HR and BP. The results indicated low physical workload and moderate mental workload amongst surgeons. It was found that the workload (physical and mental) was not dependent on the type of surgery performed. Also, the results suggested that the youngest surgeons (novice) have more mental effort than physical effort, mostly in surgeries of high complexity level, as opposed to the oldest surgeons (seniors) who have more physical effort during surgeries in low level of complexity and low mental effort in surgeries in high level of complexity.
187

Influência do diâmetro, comprimento e angulação nos torques de inserção e remoção de mini-implantes autoperfurantes /

Pignatta, Lilian Maria Brisque. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Francisco Antonio Bertoz / Banca: Marcos Rogério de Mendonça / Banca: Paulo Henrique dos Santos / Banca: Maurício Tatsuei Sakima / Banca: Júlio de Araújo Gurgel / Resumo: Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações / Abstract: Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles / Doutor
188

A anestesia inalatória com desflurano associada ou não ao óxido nitroso é genotóxica e induz estresse oxidativo em pacientes?

Nogueira, Flávia Ribeiro January 2017 (has links)
Orientador: Mariana Gobbo Braz / Resumo: O presente estudo teve como objetivo avaliar os possíveis efeitos genotóxicos e de estresse oxidativo do anestésico inalatório halogenado desflurano, associado ou não ao gás óxido nitroso (N2O). O estudo foi realizado em 40 indivíduos, de ambos os sexos, com estado físico classificado pelo American Society of Anesthesiologists (ASA) I, com idade de 18 a 50 anos. Os pacientes foram aleatoriamente alocados em dois grupos de 20, sob desflurano (6%) ou desflurano com N2O (60%) e foram submetidos a cirurgia minimamente invasiva (septoplastia) com duração mínima de 90 minutos. Amostras sanguíneas foram coletadas antes dos pacientes receberem medicação pré-anestésica (M0-controle), aos 90 minutos após o início da anestesia inalatória (M1) e na manhã do dia posterior ao ato anestésico-cirúrgico (M2). Os danos basais e oxidativos no ácido desoxirribonucleico (DNA) foram avaliados pelo teste do cometa; o estresse oxidativo foi avaliado por marcadores de peroxidação lipídica como malonaldeído (MDA) pelo método de High Performance Liquid Chromatography (HPLC), 4-hidroxinonenal (4-HNE) e 8-isoprostano pelo método de imunoensaio; a oxidação proteica foi avaliada por proteínas carboniladas por imunoensaio e o teste de defesa antioxidante plasmática analisado por fluorometria e pelo Ferric Reducing Antioxidant Power (FRAP), por espectrofotometria. Não houve diferença significante em relação os dados demográficos, tempo de cirurgia ou doses dos fármacos administrados entre os grupos. Os resul... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
189

Avaliação dos parâmetros bioquímicos e hematológicos associados ao estudo molecular para caracterização da beta-talassemia heterozigótica / Evaluation of biochemical and hematological parameters associated with molecular study for characterization of the beta-thalassemia heterozygous

Nilceia Maria Viviani 08 December 2008 (has links)
Talassemias são as mais comuns desordens monogenéticas em humanos; são caracterizadas pela presença de anemia microcíticas e hipocrômicas que resultam da redução ou ausência na síntese de uma ou mais cadeias globínicas. No Brasil a beta-talassemia tem importante significado clínico e sua ocorrência pode ser explicada como conseqüência da grande mistura étnica. A beta-talassemia é extremamente heterogênea e mais de 200 mutações têm sido descritas causando diferentes graus de anemia. Essas mutações são regionalmente específicas e cada país possui seu grupo de alterações característico. No estado homozigoto são classificadas clinicamente como major e no estado heterozigoto como intermédia e minor. Os pacientes com talassemia intermédia podem não apresentar sintomas clínicos, mas constatam-se características laboratoriais específicas. A avaliação dos índices hematológicos, dosagens dos parâmetros bioquímicos e dos valores das hemoglobinas fetal e HbA2 em combinação com o entendimento das possíveis interações gênicas são os procedimentos recomendados para o diagnóstico laboratorial. O objetivo deste estudo foi determinar a presença de mutações em pacientes que utilizam a Divisão de Laboratório Central do Hospital das Clínicas da Faculdade de Medicina da Universidade São Paulo (DLC-HC-FMUSP) e que apresentavam perfil laboratorial sugestivo para beta-talassemia. Estudou-se a região do gene da globina em onde estão descritas as mutações mais freqüentes para nosso meio através da técnica de PCR, e posterior seqüenciamento para identificação das mutações. As mutações observadas na população avaliada (N=40), em ordem crescente de freqüência foram: Codon 39 (CT), IVS-I-110 (GA), IVS-I-1(GA), IVS-I-5 (GC), IVS-I-6 (TC), IVS-I-Exon-II (GA), Exon-II-IVS-II (GA), Stop Cd 6 (GT), Stop Cd15 (GA), Del C Cd 44 e 5UTR+20. Os primeiros quatro genótipos representaram 82,5% das mutações observadas neste trabalho. O uso combinado dos índices hematimétricos, parâmetros bioquímicos e avaliação das características morfológicas das hemácias demonstraram eficiência no rastreamento de pacientes portadores de beta-talassemia, assintomáticos A técnica do PCR e posterior processo de seqüenciamento demonstraram elevada eficiência na determinação das alterações moleculares no grupo de pacientes avaliados. / Thalassemias are the most common monogenic disorders in humans; are characterized by hypochromic and microcytic anemia arising from the reduction or absence in the synthesis of one or more chains globínicas. In Brazil, beta-thalassemia has important clinical significance and its occurrence can be explained as a result of the large ethnic mix. The beta-thalassemia is extremely heterogeneous and more than 200 mutations have been described causing varying degrees of anemia, these mutations are regionally specific and each country has its characteristic group of amendments. In the homozygous state are clinically classified as major and the heterozygous state as intermediate and minor. Patients with thalassemia can not present interim clinical symptoms, but have characteristics specific laboratory. The evaluation of hematologic indices, strengths and biochemical parameters of fetal hemoglobin and HbA2 values in combination with an understanding of possible interactions genes, are the recommended procedures for laboratory diagnosis. The purpose of this study was to determine the presence of mutations in patients who use the Division of Central Laboratory of the Hospital of the Faculty of Medicine of the University Sao Paulo (DLC-HCFMUSP) who presented suggestive profile laboratory for beta-thalassemia. It was studied the region of the gene of beta globin where they are frequently described the changes to our region through the PCR technique, and subsequent sequencing to identify the mutations. Of the 40 patients evaluated were found the following changes: Codon 39 (CT), IVS-I-110 (GA), IVS-I-1 (GA), IVS-I-5 (GC), IVS-I-6 (TC), IVS-I-Exon-II (GA), Exon-II-IVS-II (GA), Stop Cd 6 (GT), Stop Cd15 (G A), Del Cd 44 and 5UTR+20. The first four genotypes accounted for 82.5% of mutations observed in this study. The combined use of hematologic indices, biochemical parameters and evaluation of morphological characteristics of red blood cells demonstrated efficiency in the tracking of patients with beta- thalassemia, asymptomatic. The technique of PCR and subsequent process of sequencing demonstrated high efficiency in determining the molecular changes in the group of patients evaluated.
190

Estudo comparativo da retenção das bandas ortodônticas Grip Tite, convencional e convencional com a superfície interna microjateada por óxido de alumínio

Vargas, Deborah Bayer Ferraz [UNESP] January 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007Bitstream added on 2014-06-13T18:56:43Z : No. of bitstreams: 1 vargas_dbf_me_arafo.pdf: 680704 bytes, checksum: b86da5b28576f3b91eb2292fc618c8b8 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo do presente trabalho foi avaliar in vitro, por meio de um ensaio mecânico, a força necessária para a remoção das bandas ortodônticas Grip Tite (C), Convencional (A) e banda Convencional com a superfície interna microjateada por óxido de alumínio (B). Também analisar visualmente a quantidade de cimento residual, e classificar usando uma escala de incrementos a 25%. Após, verificar, por meio de MEV, a superfície com melhores características para a retenção. Os resultados obtidos mostraram que a média de carga do Grupo B, bandas microjateadas internamente por óxido de alumínio, foi significantemente maior que as médias dos Grupos A, bandas Convencionais, e C, bandas Grip Tite. Quanto a quantidade de cimento remanescente nas bandas, o Grupo B apresentou 100% das bandas com índice 4, indicando a presença de mais de 75% de cimento residual nas bandas, enquanto que nos Grupos A e C, houve a predominância do índice 1, indicativo de menos de 25% de cimento residual nas bandas, sem diferença significativa entre esses dois grupos. Os resultados foram confirmados pela MEV, onde observou-se uma superfície com melhores características para a retenção do cimento nas bandas onde foi realizado o processo de microjateamento. Conclui-se que o processo de microjateamento por óxido de alumínio, na superfície interna das bandas convencionais, aumenta a força necessária para a remoção das bandas e aumenta a quantidade de cimento residual preso à superfície da banda. Quando analisada pela MEV, essa superfície apresenta-se como a mais áspera e rugosa, com a maior quantidade de cimento de ionômero de vidro aderido à banda. / The purpose of this study was to evaluate in vitro, the necessary force for the removal of Grip Tite, Conventional and Sandblasted orthodontics molar bands, as well as, to analyze and to classify the amount of residual cement in the internal surface of these bands. After that, checking through scanning electron microscopy, the surface with better characteristics for the retention. The obtained results showed that the load average of the group B, Sandblasted bands, was significantly higher than the group A, Conventional bands, and C, Grip Tite bands. Observing the amount of remaining cement in the bands, group B presented 100% of the bands with index 4, indicating the presence of more than 75% of residual cement in the bands, while in the groups A and C, had the predominance of index 1, indicative of less than 25% of residual cement in the bands, without significant difference between these two groups. The results were confirmed by the scanning electronic microscopy, where the surface with better characteristics for the retention of the cement was observed, in the bands where the sandblasted process was carried through. It was concluded that the process of sandblasted, in the internal surface of the conventional bands, increases the necessary force for the removal of the bands and increases the amount of residual cement in the internal surface of the band. When analyzed by the scanning electronic microscopy, this surface appeared rougher and corrugated, with great amount of glass ionomer cement adhered to the band.

Page generated in 0.0507 seconds