• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 153
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 162
  • 162
  • 132
  • 108
  • 97
  • 76
  • 47
  • 34
  • 33
  • 33
  • 32
  • 27
  • 26
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

[en] REMOVAL OF HUMIC ACIDS FROM WATERS WITH PURPOSE POTABILITY USING FENTON REAGENT AS PRÉ-OXIDANT IN WATER TREATMENT PROCESSES / [pt] REMOÇÃO DE ÁCIDOS HÚMICOS DE ÁGUAS COM FINS DE POTABILIDADE UTILIZANDO O REAGENTE DE FENTON COMO PRÉ-OXIDANTE EM PROCESSOS DE TRATAMENTO DE ÁGUA

ANA CAROLINA PATTACINI GALDINO 19 April 2017 (has links)
[pt] A água potável é essencial para uma boa qualidade de vida e saúde da população. Nos mananciais, a água naturalmente encontrada possui matéria orgânica e microorganismos, alguns até mesmo patogênicos, sendo necessário o seu tratamento em estações de tratamento de água (ETAs). O cloro é o principal reagente atualmente utilizado como pré-oxidante da matéria orgânica em ETAs, gerando compostos organo-halogenados de características cancerígenas. Neste trabalho foi realizado um estudo do reagente de Fenton como pré-oxidante com o fim de degradar os ácidos húmicos (AH), que são os principais constituintes da matéria orgânica naturalmente encontrada em águas de mananciais, sem a geração dos compostos organo-halogenados. Para isto, foram realizados experimentos de acordo com um planejamento fatorial 23 que investigou a influência de três variáveis na degradação de AH: pH, dosagem de peróxido de hidrogênio e razão molar [H2O2]:[Fe elevado a 2 positivo]. Os resultados obtidos a partir destes experimentos mostraram que todas as variáveis influenciaram na degradação do AH, de forma que o aumento tanto da dosagem de peróxido de hidrogênio quanto da razão molar [H2O2]:[Fe elevado a 2 positivo] gera o aumento na degradação de AH. Com relação ao pH, o aumento desta variável gerou uma ligeira queda na degradação de AH. Assim, a partir de todos os experimentos verificou-se que aquele de melhor resultado apresenta as seguintes condições operacionais: dosagem de peróxido de hidrogênio igual a 42,98 mg/L, [H2O2]:[Fe elevado a 2 positivo] igual 3:1, pH igual a 7. Nestas condições operacionais, após 5 minutos de reação, a redução de AH foi de 95,66 por cento, a redução de COT de 24,94 por cento e a velocidade inicial de degradação de AH de 9,38 mg/L.min. / [en] Drinking water is essential to a good quality of life and health of the populations. In the surface, the water found naturally contains organic matter and microorganisms, some even pathogenic, requiring their removal in water treatment plants (WTPs). Chlorine is the main reagent currently used as pre-oxidant of the organic matter in WTPs, generating chlorinated organic compounds of carcinogenic characteristics. In this project a study of the Fenton reagent as pre-oxidant has been conducted in order to degrade the humic acids (HA), which are the main constituents of the organic matter naturally found in water sources without generating the chlorinated organics. For this, experiments have been conducted according to a factorial design 23 which investigated the influence of three variables in the HA degradation: pH; hydrogen peroxide dosage; and molar ratio [H2O2]:[Fe to the power of 2 positive]. The results obtained from these experiments showed that all variables influence the degradation of HA, so that the increase of the hydrogen peroxide dosage as well as the molar ratio [H2O2]:[Fe to the power of 2 positive] increase HA degradation. With regard to the pH, the increase of this variable generates a slight drop in AH degradation. Thus, from all experiments it has been verified that that the best result were obtained in the following operating conditions: hydrogen peroxide dosage equal 42,98 mg/L, [H2O2]:[Fe to the power of 2 positive] equal 3:1, pH equal 7. Under these operating conditions, after 5 minutes of batch reaction, the reduction of HA was 95,66 percent, the TOC reduction of 24,94 percent and the initial rate of HA degradation of 9,38 mg/L.min.
62

Processo oxidativos avançados na remoção da toxicidade e da atividade antimicrobiana de uma solução de ofloxacina / Advanced oxidation processes in toxicity and antimicrobial activity removal of an ofloxacin solution

Peres, Marcela Souza, 1984- 24 August 2018 (has links)
Orientador: José Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T08:56:07Z (GMT). No. of bitstreams: 1 Peres_MarcelaSouza_M.pdf: 1942738 bytes, checksum: e568a9f4c6bc9579df4ca7bc831e9085 (MD5) Previous issue date: 2014 / Resumo: A ofloxacina é um antimicrobiano de amplo espectro frequentemente encontrado em concentrações significativas em efluentes e águas superficiais. A contínua introdução deste fármaco no meio ambiente constitui um risco potencial em longo prazo para os organismos não alvos ou para a saúde humana. Neste estudo foi avaliada a degradação da ofloxacina pelos processos oxidativos avançados (POA) peroxidação assistida por radiação ultravioleta (UV/H2O2) e fotocatálise (UV/TiO2 e UV/TiO2/H2O2). Foi avaliada também a atividade antimicrobiana residual do fármaco, utilizando a bactéria E. coli, e a toxicidade aguda (Vibrio fischeri). A concentração de ofloxacina foi monitorada utilizando-se cromatografia líquida de alta eficiência (CLAE). Os resultados obtidos indicam que os POA aplicados foram eficientes para a degradação desse fármaco. O processo UV/H2O2 alcançou degradação de 99%, após 60 min de reação. Para o processo UV/TiO2, a eficiência de degradação obtida foi de 89,3% após 60 min e a adição de peróxido de hidrogênio elevou a eficiência para 97,8%. A atividade antimicrobiana do fármaco foi reduzida consideravelmente, alcançando 95% de remoção com a aplicação do UV/H2O2 e 96% utilizando o processo UV/TiO2/H2O2. A toxicidade das amostras não aumentou no decorrer da aplicação destes POA, indicando a potencial utilização destes processos para o tratamento de soluções aquosas contendo ofloxacina / Abstract: Ofloxacin is a broad-spectrum antimicrobial agent which is frequently found in significant concentrations in wastewater and surface water. Its continuous introduction into the environment constitutes a potential risk to non-target organisms or to human health. This study evaluated ofloxacin degradation by the UV/H2O2, UV/TiO2 and UV/TiO2/H2O2 advanced oxidation process (AOPs), residual antimicrobial activity (E. coli), and acute toxicity (Vibrio fischeri). Ofloxacin concentration was monitored with HPLC analyses. The results obtained shown that AOPs applied were efficient for ofloxacin degradation. For UV/H2O2, degradation efficiency was 99% in 60 min of reaction. For UV/TiO2, degradation efficiency was 89.3% in 60 min of reaction when applied 128 mg L-1 TiO2. The addition of 1.68 mmol L-1 of hydrogen peroxide increased the degradation to 97.8%. For both processes, the antimicrobial activity was considerably reduced throughout the reaction, reaching 95% removal when UV/H2O2 was applied and 96% using the UV/TiO2/H2O2 process. The toxicity of the samples did not increase during AOP application, indicating the potential use of these processes for the treatment of aqueous solutions containing ofloxacin / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
63

Estudo da aplicação de ZnO fotoirradiado com luz solar no tratamento de efluentes de laticínios / Study of application of ZnO using solar photoirradiation in dairy wastewater

Samanamud, Gisella Rossana Lamas 28 February 2011 (has links)
Os produtos lácteos são tidos como os alimentos mais perfeitos para o homem devido ao seu alto valor nutritivo. Entretanto, esses produtos vêm refletidos na elevada carga orgânica de efluente gerado. Os Processos Oxidativos Avançados (POA) são métodos químicos baseados na geração de radicais hidroxilas, que promovem a oxidação de compostos orgânicos. O uso de semicondutores no tratamento de efluentes tem sido de grande interesse devido à sua alta eficiência, estabilidade fotoquímica, natureza não-tóxica e baixo custo, especialmente quando a luz do sol é usada como fonte de irradiação. O uso de Óxido de Zinco (ZnO), por exemplo, além de mais econômico, absorve uma fração maior de espectro UV e tem melhor desempenho em pH neutro. Este estudo consistiu em avaliar a aplicação e eficiência da fotocatálise heterogênea (POA) solar com ZnO em termos de percentual de degradação de Carga Orgânica Total (COT) para um posterior tratamento biológico aerado visando melhorar as condições de despejo do efluente de modo a preservar o ecossistema e economia dos recursos naturais. O sistema POA consistiu de um volume fixo de efluente de 3L, de uma chapa metálica 800 x 250 mm revestida com uma formulação de tinta contendo ZnO, um reservatório de vidro, uma bomba centrífuga e aberto para absorção de radiações UV solar. Os resultados foram obtidos e analisados a partir do método de planejamento de experimentos em termos de percentual de degradação de COT. O melhor resultado apresentou um percentual de degradação de COT de 31,5% onde os níves das variáveis estudadas ocorreram em pH 8,0 em chapa de ZnO com espessura de 100 micrômetros (?m), utilizando o efluente in natura e o tempo total de reação de 3 h (180min). O efluente tratado pelo POA solar com ZnO foi submetido ao tratamento biológico aerado. O pH ótimo e a concentração de lodo foram de 6,0 e 5,0 mg/L, respectivamente. O percentual de degradação de COT para os tratamentos combinados foi de 75,1 % para o efluente de laticínios utilizado neste estudo. Isto sugere que o tratamento por POA utilizando ZnO seguido de um Tratamento Biológico Aerado seria uma alternativa promissora no tratamento de efluentes de laticínios. / Dairy products are the most perfect type of food for men due to its high nutritive value reflected on its high organic load of wastewater generated. The Advanced Oxidation Processes (AOP) are chemical methods based on the generation of hydroxyls radicals that promote the oxidation of organic compounds. The use of semiconductors in wastewater treatment has been of great interest owing to its high efficiency, photochemical stability, non-toxic nature and lower costs, especially when sunlight is used as source of irradiation. The use of Zinc Oxide (ZnO), for instance, besides being more economic, it also absorbs a greater range of UV spectrum and it has a better performance on neutral pH. This study consisted in evaluating the application and efficiency of solar photocatalytic oxidation (AOP) with ZnO in percentage terms of removal of Total Organic Carbon (TOC) prior to an aerobic biological treatment aiming to improve the conditions of the disposal of this wastewater in order to conserve the water environment and saving natural resources. The AOP system consisted of a working volume of 3 L, a sheet metal 800 x 250 mm covered with a paint formula containing ZnO, a glass vessel, a pump and an open system in order to collect solar UV radiation. The results were obtained and analyzed from design of experiments in terms of percentage of removal of TOC. The maximum percentage was found to be 31.5 % of removal of TOC and at pH 8.0, thickness of the sheet containing ZnO of 100 micrometers (?m), wastewater in natura and total time of reaction of 3 h (180 min). The solar AOP with ZnO treated wastewater was subjected to an aerobic biological treatment. The optimum pH and sludge loading were of 6.0 and 5.0 mg/L, respectively. The combination of both treatments resulted in 75.1 % of removal of TOC from the dairy wastewater used in this study. This suggests that the AOP using ZnO followed by an aerobic biological treatment would be a promising alternative for the treatment of dairy wastewater.
64

Estudo da aplicação de UV/FENTON (Fe2+/H2O2) no tratamento de efluentes de laticínios / Study of the Application of UV/Fenton (Fe2+ + H2O2) in the Treatment of Dairy Effluent.

Loures, Carla Cristina Almeida 25 February 2011 (has links)
O efluente lácteo é o resíduo obtido no beneficiamento do leite e seus derivados, sendo considerado um passivo de alto poder poluidor. Sem o devido tratamento, quando lançado nos rios compromete a sobrevivência da biota como um todo. O objetivo deste trabalho consistiu em avaliar a eficiência e aplicação do processo Foto-Fenton, seguido por um tratamento biológico (lodo ativado), para a redução da carga orgânica do efluente em questão. A caracterização do efluente lácteo in natura e tratado foi realizada empregando-se métodos estabelecidos e otimizados [DQO, COT, DBO5, Nitrogênio (orgânico e amoniacal), Fósforo total, Ferro, e Sólidos (ST, STF, STV), fenol, análise de elementos via absorção atômica]. Por meio de planejamentos estatísticos - Taguchi, Box-Behnken e fatorial completo - foram determinados os melhores experimentos posteriores aos tratamentos fotocatalíticos e biológico, tendo como variável resposta a redução percentual de COT. Após o processo fotocatalítico, a amostra do melhor experimento foi tratada por um processo biológico (Sistema Lodo Ativado SLA), a fim de verificar a eficiência de degradação da matéria orgânica do efluente estudado através do sistema conjugado (POA- SLA). O sistema híbrido que apresentou maior eficiência teve como variáveis do processo de tratamento fotoquímico: pH = 3,5; Temperatura = 30 ºC; reagente Fenton ( 35 g H2O2 + 3,6 g Fe2+ ) e potência de radiação ultravioleta de 28 W, para um tempo de reação de 60 minutos. Para o tratamento biológico por lodo ativado, os melhores níveis das variáveis foram realizados em pH = 8 e concentração de lodo de 3,0 g L-1. Os resultados para o tratamento híbrido apresentou percentuais de reduções para COT = 94 %, DQO = 97 % e DBO = 83 %. / The dairy effluent is the residue obtained from the improvement of milk and its derivatives, being considered a high pollutant. Without the due treatment, when thrown in the rivers it puts in risk the survival of the biota as a whole. The objective of this work consisted of evaluating the efficiency and application of the process photo-Fenton followed by a biological (activated sludge) treatment for the reduction of the organic load of the effluent. The characterization of the dairy effluent in natura and treated was accomplished using established methods [COD, TOC, BOD5, Nitrogen (organic and amoniacal), Total Phosphorus, Iron, and Solids (TS, FTS, VTS), phenol, analysis of elements through atomic absorption]. Through statistical designs, Taguchi, Box-Behnken and Full Factorial, the best experiments were determined for the photocatalytic and biological treatments having the reduction of TOC as their response. After the photocatalytic process, the sample of the best experiment was treated by a biological process in order to verify the efficiency of degradation of the organic matter of the effluent studied through the conjugated (AOP - AS) system. The hybrid system that presented larger efficiency had as factors of the photochemical treatment: pH = 3,5, temperature = 30 ºC, Fenton\'s reagent (35g H2O2 + 3,6 g Fe2+) and potency of ultraviolet radiation of 28 W, for 60 minutes of reaction time. As for the biological treatment, it was accomplished in pH = 8 and concentration of sludge of 3g L-1. Obtained were of the hybrid system the percentage of reductions of TOC = 94 %, COD = 97 % and BOD = 83 %.
65

Aplicação de processo oxidativo avançado (POA) como pré-tratamento de efluente de laticínio para posterior tratamento biológico / Aplication of Advanced Oxidative Process (AOP) as pretreatment of dairy wastewater for subsequent biologic treatment

Salazar, Rodrigo Fernando dos Santos 09 March 2009 (has links)
O foco deste trabalho foi desenvolver um sistema de tratamento híbrido, constituído por um pré-tratamento fotocatalítico heterogêneo (POA) e posterior tratamento biológico por lodo ativado (SLA), para a redução da carga orgânica de efluentes laticinista oriundos do processamento de lácteos líquidos, como por exemplos, cremes, iogurte e beneficiamento de leite. Para a caracterização analítica do efluente in natura e tratado empregaram-se as metodologias Standard Methods, validadas em função do tipo e da complexidade da amostra (DQO, DBO, Norgânico, N-NH4 +, PTotal, Fe2+, O&G, ST, STF, STV, SS, SD, Al, As, Ca, Fe, Mge Pb). Através de planejamentos fatoriais determinaram-se as melhores condições entre as variáveis estudadas para as etapas de tratamentos com POA e lodo ativado, tendo como fator de resposta a redução da DQO. Para a etapa de POA empregou-se a fotocatálise, utilizando como semicondutor o dióxido de titânio (TiO2) finamente distribuído e fixado com tinta poliuretânica sobre uma chapa metálica plana, onde o efluente foi percolado sobre o respectivo leito catalítico posicionado em um ângulo fixo de 23º, recebendo a radiação solar direta. O dois tipos de estrutura de TiO2 (rutilo ou anatase) foram avaliados morfologicamente (DRX, BET, MEV-EDS) e cineticamente, como uma variável do processo fotocatalítico: a fase anatase apresentou maior eficiência de degradação da matéria orgânica, em pH 5. Posteriormente à degradação da carga orgânica por reação fotoquímica, as amostras foram tratadas biologicamente por lodo ativado e, conseqüentemente, pode-se analisar e otimizar um sistema híbrido (POA - SLA) que apresentasse maior eficiência de degradação da matéria orgânica do efluente lácteo utilizado. Ensaios de biodegradação sem o pré-tratamento com POA apresentou uma redução de 26,01 ± 5,23 % em 72 h de tratamento. O sistema (POA - SLA) que apresentou maior eficiência de degradação da matéria orgânica, em 72 h de tratamento, foi de 93,70 ± 0,10 % caracterizado por uma DQO de entrada em 3782,5 ± 37,6 mg O2 L-1 e uma DQO de saída (efluente tratado) em 236,8 ± 0,1 mg O2 L-1. / The aim of this work is at developing a hybrid system in order to treat dairy wastewater. The hybrid system was composed by two modules. The first one is based in advanced oxidative process (AOP) and the second in actived sludge system (SLA). Methodologies from Standard Methods were adaptded and validated (BOD, COD, Norganic, N - NH4 +, Ptotal, Fe2+, G&O, TS, TFS, VSS, TSS, TDS, Al, As, Ca, Fe, Mg and Pb) for dairy effluent characterization. The best conditions for AOP and SLA processes had been determined through Designs of Experiments (DOE). The efficiency of both processes was avaliabled by COD. AOP treatment based on photocatalisis was applied. Titanium dioxide (TiO2) was used as semiconductor. This TiO2 was finely distributed and settled with poliuretanic ink on a plain metallic plate where the effluent was circulated on the respective located catalytic stream bed in fixed angle of 23º. This process (AOP) received direct solar radiation. Two types of crystalline structure of TiO2 (rutile or anatase) had been evaluated morphologically (XRD, BET, SEM-EDS) and kinetically, as an variable of photocatalisis process: the anatase crystalline phase in pH 5 have shown better degradation of dairy wastewater. The samples had been treated by SLA later photochemical reaction. The hybrid system (AOP - SLA) was then analyzed and optimized. 72 hours of biodegradation tests without AOP pretreatment had been shown 26,01 ± 5,23 % of COD reduction. Over optimized conditions the hybrid system showed 93,70 ± 0,10 % of COD reduction with a initial organic load of 3782,5 ± 37,6 mg O2 L-1 and final COD of 236,8 ± 0,1 mg O2 L-1 (treated effluent).
66

Avaliação de processos oxidativos para o tratamento ambientalmente adequado de fluidos de corte / Evaluation of oxidative processes for the environmentally apropriate treatment of cutting fluids

Tessaro, Elias Paulo 17 April 2008 (has links)
Durante o processo metalúrgico de usinagem de uma peça ocorre a geração de calor proveniente do atrito ferramenta/peça e cavaco/ferramenta. Para que ocorra uma menor geração de calor possibilitando o manuseio, bem como a minimização na deformação da peça, utilizam-se fluidos, que são soluções lubrificantes à base de óleos, água ou polímeros, podendo ser sintéticos ou não, diminuindo, assim, o coeficiente de atrito reduzindo-se a quantidade de calor gerado no processo. Há uma grande variedade de fluidos de corte disponíveis no mercado que são constituídos por diversos compostos como: aminas, compostos clorados e/ou aromáticos, glicóis, nitrosaminas além da presença de metais provenientes do processo de manufatura, portanto, sem tratamento, não podem ser lançados na rede de esgoto convencional. Atualmente não há um método de tratamento para os fluidos de corte nas indústrias. Nesse contexto, propõe-se um estudo sobre a viabilidade dos tipos de tratamento dos fluidos de corte para uma disposição adequada. Os processos de tratamento propostos neste trabalho compreendem hidrolise ácida e Processo Oxidativo Avançado (POA), mais especificamente, Sistema Fenton, além de propor um tratamento baseado na fotodegradação. A caracterização do fluido antes e após seu tratamento foi realizada por técnicas analíticas e espectrométricas. Os processos oxidativos mostraram-se satisfatórios para o tratamento dos efluentes, reduzindo os níveis de contaminantes aos permitidos pela legislação. O processo foto-Fenton mostrou-se mais eficiente que o processo Fenton na degradação de todos os parâmetros avaliados, incluindo BTEX e HPAs. Os processos de hidrólise ácida não apresentaram resultados satisfatórios, reduzindo apenas os metais aos níveis permitidos para descarte. / During the cutting process, part of the heat generation results from tool-part and chip-tool friction. So that it happens a smaller generation of heat making possible the handling, as well as minimization in the tool deformation, cutting fluids are used, that are the oils base, water or polymeric lubricating solutions, could be synthetic or no, decreasing the attrition coefficient being reduced the amount of heat generated in the process. There is a great variety of cutting fluids that are constituted for several composed as: amines, chlorinated and/or aromatic composed, glycols and nitrosamines besides the presence of metals proceeding of manufacture process, therefore, without a treatment, they cannot be discarded in the conventional sewerage system. At the moment there isn\'t a treatment method for the cut fluids in the industries. In that context, intends a study about the viability types of cutting fluids treatment for appropriate disposition. Treatment processes proposed in this work understand acid hydrolysis and Advanced Oxidative Process (AOP), more specifically, Fenton System, in addition proposing a treatment based on the photodegradation (photo-Fenton process). The characterization of fluid before and after treatment it was accomplished by analytical and spectrometry techniques. Oxidative processes were exposed satisfactory for cutting fluids treatment, reducing the levels of pollutants to the allowed by the legislation. Photo-Fenton process was shown more efficient than Fenton process in the oxidation of BTEX and PAHs. Acid hydrolysis processes didn\'t present satisfactory results, just reducing the metals at the levels allowed for discard.
67

Estudo da aplicação de ZnO fotoirradiado com luz solar no tratamento de efluentes de laticínios / Study of application of ZnO using solar photoirradiation in dairy wastewater

Gisella Rossana Lamas Samanamud 28 February 2011 (has links)
Os produtos lácteos são tidos como os alimentos mais perfeitos para o homem devido ao seu alto valor nutritivo. Entretanto, esses produtos vêm refletidos na elevada carga orgânica de efluente gerado. Os Processos Oxidativos Avançados (POA) são métodos químicos baseados na geração de radicais hidroxilas, que promovem a oxidação de compostos orgânicos. O uso de semicondutores no tratamento de efluentes tem sido de grande interesse devido à sua alta eficiência, estabilidade fotoquímica, natureza não-tóxica e baixo custo, especialmente quando a luz do sol é usada como fonte de irradiação. O uso de Óxido de Zinco (ZnO), por exemplo, além de mais econômico, absorve uma fração maior de espectro UV e tem melhor desempenho em pH neutro. Este estudo consistiu em avaliar a aplicação e eficiência da fotocatálise heterogênea (POA) solar com ZnO em termos de percentual de degradação de Carga Orgânica Total (COT) para um posterior tratamento biológico aerado visando melhorar as condições de despejo do efluente de modo a preservar o ecossistema e economia dos recursos naturais. O sistema POA consistiu de um volume fixo de efluente de 3L, de uma chapa metálica 800 x 250 mm revestida com uma formulação de tinta contendo ZnO, um reservatório de vidro, uma bomba centrífuga e aberto para absorção de radiações UV solar. Os resultados foram obtidos e analisados a partir do método de planejamento de experimentos em termos de percentual de degradação de COT. O melhor resultado apresentou um percentual de degradação de COT de 31,5% onde os níves das variáveis estudadas ocorreram em pH 8,0 em chapa de ZnO com espessura de 100 micrômetros (?m), utilizando o efluente in natura e o tempo total de reação de 3 h (180min). O efluente tratado pelo POA solar com ZnO foi submetido ao tratamento biológico aerado. O pH ótimo e a concentração de lodo foram de 6,0 e 5,0 mg/L, respectivamente. O percentual de degradação de COT para os tratamentos combinados foi de 75,1 % para o efluente de laticínios utilizado neste estudo. Isto sugere que o tratamento por POA utilizando ZnO seguido de um Tratamento Biológico Aerado seria uma alternativa promissora no tratamento de efluentes de laticínios. / Dairy products are the most perfect type of food for men due to its high nutritive value reflected on its high organic load of wastewater generated. The Advanced Oxidation Processes (AOP) are chemical methods based on the generation of hydroxyls radicals that promote the oxidation of organic compounds. The use of semiconductors in wastewater treatment has been of great interest owing to its high efficiency, photochemical stability, non-toxic nature and lower costs, especially when sunlight is used as source of irradiation. The use of Zinc Oxide (ZnO), for instance, besides being more economic, it also absorbs a greater range of UV spectrum and it has a better performance on neutral pH. This study consisted in evaluating the application and efficiency of solar photocatalytic oxidation (AOP) with ZnO in percentage terms of removal of Total Organic Carbon (TOC) prior to an aerobic biological treatment aiming to improve the conditions of the disposal of this wastewater in order to conserve the water environment and saving natural resources. The AOP system consisted of a working volume of 3 L, a sheet metal 800 x 250 mm covered with a paint formula containing ZnO, a glass vessel, a pump and an open system in order to collect solar UV radiation. The results were obtained and analyzed from design of experiments in terms of percentage of removal of TOC. The maximum percentage was found to be 31.5 % of removal of TOC and at pH 8.0, thickness of the sheet containing ZnO of 100 micrometers (?m), wastewater in natura and total time of reaction of 3 h (180 min). The solar AOP with ZnO treated wastewater was subjected to an aerobic biological treatment. The optimum pH and sludge loading were of 6.0 and 5.0 mg/L, respectively. The combination of both treatments resulted in 75.1 % of removal of TOC from the dairy wastewater used in this study. This suggests that the AOP using ZnO followed by an aerobic biological treatment would be a promising alternative for the treatment of dairy wastewater.
68

Avaliação de métodos emergentes visando aumentar a eficiência do ozônio na mineralização do azocorante Preto Remazol B / Evaluation of emergent methods aiming at to increase the efficiency of ozone in the mineralization of the azodye Remazol Black B

Mahmoud, Amira 03 October 2006 (has links)
Neste trabalho buscaram-se formas de aumentar a eficiência do processo de ozonização sobre a degradação/mineralização de corantes empregados pela indústria têxtil, especificamente do azocorante Preto Remazol B, avaliando o emprego do processo de ozonização catalítica tanto homogênea quanto heterogênea. O ozônio mostrou uma grande eficiência para promover a degradação dos três tipos de corantes estudados (azo, antraquinona e ftalocianina); permitindo que soluções destes corantes com concentração de 100 mg L-1 sofressem uma total descoloração (destruição do grupo cromóforo) em menos de 2 minutos de ozonização. Em meio ácido, o ozônio tende a reagir via o mecanismo direto e devido a isto a redução no teor de carbono orgânico total (COT) dos poluentes costuma ser menos eficiente. Em 30 minutos de tratamento o processo O3/pH3 permitiu somente 30% de mineralização do azocorante estudado. Por outro lado, o O3 pode ter sua decomposição catalisada por vários materiais, levando à formação de espécies radicalares, principalmente o radical hidroxila (HO.). Devido ao caráter não seletivo dos radicais hidroxila, o mecanismo de ozonização indireto costuma ser mais eficiente na oxidação de compostos orgânicos. Um exemplo clássico deste mecanismo é o processo O3/pH11, que mineralizou 56% do COT do azocorante após 30 minutos de ozonização. Uma estratégia para promover uma melhora na mineralização do corante Preto Remazol B pelo processo de ozonização em meio ácido foi a adição de peróxido de hidrogênio ao meio reacional. O tratamento O3/pH3/H2O2 permitiu um aumento de 51% na mineralização do azocorante após 30 minutos de ozonização. O aumento da eficiência do ozônio também foi avaliado empregando-se o processo de ozonização na presença de metais (Mn2+e Fe3+). Em 30 minutos de tratamento, o processo O3/pH3/Mn2+ mineralizou 67, 78 e 57% do COT dos corantes Preto Remazol B, Azul Brilhante RN e Turquesa Remazol G, respectivamente. No mesmo tempo de tratamento O3/pH3/Fe3+ permitiu uma remoção de COT de 57, 64 e 41% para Preto Remazol B, Azul Brilhante RN e Turquesa Remazol G, respectivamente. A presença dos metais estudados na forma sólida (MnO2) ou em suportes (SiO2/MnO2 e SiO2/Fe2O3), além de permitir uma remoção de até 79% do COT do azocorante em 30 minutos de tratamento, também mostra uma alternativa para viabilizar o emprego dos agentes catalisadores da decomposição do ozônio, uma vez que na forma suportada os mesmos podem ser utilizados de forma contínua, minimizando etapas de recuperação ou perdas destes materiais. / The main goal of this study was to find means to increase the efficiency of ozonation process over the degradation/mineralization of dyes used in the textile industry, mainly the azodye Remazol Black B, evaluating the use of either homogeneous or heterogeneous catalytic ozonation methods. Ozone showed great efficiency to promote the degradation of the three types of studied dyes (azo, anthraquinone and phtalocyanine) enabling the discoloration (destruction of chromophore group) of solutions with 100 mgdye L-1 in less than 2 minutes. In acidic medium, ozone tends to react via the direct mechanism. In this way, the reduction of total organic carbon (TOC) of the polluents uses to be less efficient. In 30 minutes of treatment, the process O3/pH3 allowed only 30% of mineralization of the studied azodye. On the other hand, O3 can be decomposed by several materials, leading to the formation of radical species, mainly the hydroxyl radical (HO.). Due to the nonselective character of hydroxyl radicals, the indirect mechanism of ozonation usually is more efficient in the oxidation of organic compounds. A classic example of this mechanism is the process O3/pH11 that mineralized 56% of TOC of the azodye after 30 minutes of ozonation. Another strategy to promote an improvement in the mineralization of the azodye Remazol Black B using the ozonation process in acid medium was the addition of hydrogen peroxide to the reactional medium. The treatment O3/pH3/H2O2 enabled an increase of 51% in the mineralization of the azodye after 30 minutes. The increase in the efficiency of ozone was also evaluated using the ozonation process in the presence of metallic ions (Mn2+ and Fe3+). In 30 minutes of treatment, the process O3/pH3/Mn2+ mineralized 67, 78 and 57% of the TOC of the dyes Remazol Black B, Blue Brilliant RN and Remazol Turquoise G133, respectively. In the same time of treatment, the process O3/pH3/Fe3+ mineralized 57, 64 and 41% of the TOC of he dyes Remazol Black B, Blue Brilliant RN and Remazol Turquoise G133, respectively. The presence of the studied metals in the solid form (MnO2) or on supports (SiO2/MnO2 e SiO2/Fe2O3), enabled the removal of up to 79% of the TOC of the azo in 30 minutes of ozonation. Moreover, these methods showed an alternative to permit the use of catalytic agents to decompose ozone, as in the supported form, they can be used in a continuous form, minimizing steps of recuperation or loss of these materials.
69

Aplicação de processos oxidativos e digestão anaeróbia na estabilização de efluente da liquefação hidrotermal de Spirulina / Application of oxidative processes and anaerobic digestion in the stabilization of hydrothermal liquefaction of Spirulina wastewater

Quispe-Arpasi, Diana Elizabeth 19 October 2016 (has links)
O processo de liquefação hidrotermal (HTL) pode converter diversos tipos de biomassa em óleo bruto. Além do produto principal, é gerado um efluente (PHWW) com elevada carga orgânica, quantidades altas de nutrientes e compostos tóxicos. Para lidar com este tipo efluente tem-se sugerido a combinação de tratamentos físico-químicos e biológicos. O objetivo deste estudo foi avaliar a aplicação de processos oxidativos (por H2O2 e fotocatálise com TiO2) e digestão anaeróbia no tratamento do efluente da liquefação hidrotermal de Spirulina. Inicialmente caracterizou-se o efluente em termos de carga orgânica, nutrientes e compostos nitrogenados cíclicos (CNC). Posteriormente, avaliou-se a concentração de oxidante e o tempo de reação no processo de oxidação com H2O2. O tratamento fotocatalítico foi então avaliada no tratamento do efluente em questão, isoladamente, em sequência e combinada ao processo de oxidação por ação de H2O2. Finalmente combinaram-se os processos de oxidação por ação de H2O2 e digestão anaeróbia no tratamento de efluente de PHWW. O efluente da liquefação hidrotermal de Spirulina apresentou elevada carga orgânica, pH alcalino e concentrações altas de nutrientes (nitrogênio e fósforo). Verificou-se também a presença de CNC como pirazinas, δ-valerolactama, caprolactama e butirolactama. A aplicação do processo oxidativo por H2O2 no tratamento de PHWW apresentou efeitos positivos, principalmente para a descoloração que atingiu 93,8 %. A eficiência máxima de remoção de DQO foi de 15,3%. Foi percebida também redução nas concentrações dos CNC. A eficiência do processo de oxidação avançada por fotocatálise e H2O2 foi maior do que obtida quando estes processos foram aplicados separadamente. A aplicação dos processos combinados apresentou eficiência de remoção de cor e DQO semelhante às obtidas quando os processos foram aplicados em sequência, propiciando economia de tempo de reação. Por fim, verificou-se que a digestão anaeróbia do efluente pré-tratado com H2O2 apresentou maior produção de CH4 e remoção de matéria orgânica quando comparada com a digestão anaeróbia que o efluente in natura. Assim, conclui-se a utlização de processos oxidativos avançados ou a combinação da oxidação por H2O2 com a digestão anaeróbia são alternativas promissoras para o tratamento da PHWW. / The hydrothermal liquefaction process (HTL) can convert various types of biomass into bio-crude oil. In addition to the main product, wastewater (PHWW) is generated with high organic content, high amounts of nutrients and toxic compounds. To cope with this type of wastewater the combination of physicochemical and biological treatments has been suggested. The aim of this study was to evaluate the application of oxidative processes (using H2O2 and photocatalysis with TiO2) and anaerobic digestion in the treatment of hydrothermal liquefaction of Spirulina wastewater. Firstly, PHWW was characterized in terms of organic matter, nutrients and nitrogen heterocyclic compounds (CNC) concentrations. Secondly, the oxidant concentration and the reaction time in the oxidation process using H2O2 was evaluated. Photocatalytic treatment was then tested isolated, in sequence and combinated with the oxidation processo using H2O2. Finally, oxidation with H2O2 and anaerobic digestion were combinated and evaluated. The PHWW showed high organic load, alkaline pH and high concentrations of nutrients (nitrogen and phosphorus). The presence of CNC as pyrazines, δ-valerolactam, caprolactam and butyrolactam was also verified. The application of the oxidative process using H2O2 showed positive effects mainly for color removal, which reached 93.8%. The maximum efficiency of COD removal was 15.3%. Reduction in CNC concentrations was also observed . The efficiency of the advanced oxidation process (by combining photocatalysis and H2O2) was greater than that obtained when these processes were applied separately. The application of the combined process presented color and COD removal efficiencies similar to those obtained when the processes were applied in sequence, allowing reaction time savings. Finally, the anaerobic digestion of pre-treated (with H2O2) PHWW showed a greater CH4 production and higher organic matter removal, compared to anaerobic digestion of in natura PHWW. Thus it is possible to conclude that the utlization of advanced oxidation processes or the combination of oxidation with H2O2 and anaerobic digestion are promising alternatives for the treatment of PHWW.
70

Estudo da aplicação de foto-fenton solar como tratamento de chorume proveniente do aterro sanitário de Cachoeira Paulista-SP / Study of the Application of Solar Photo Fenton Treatment as leachate from the Landfill Cachoeira Paulista-SP

Cavalcanti, Alessandro Sampaio 12 April 2013 (has links)
O chorume in natura utilizado foi proveniente do aterro sanitário da cidade de Cachoeira Paulista no interior do estado de São Paulo. Possui baixa razão de biodegradabilidade (DBO/DQO = 0,094) evidenciado principalmente através das análises de caracterização dos parâmetros COT (618,1 mg C/L), DQO (4345,88 mg O2/L) e DBO5 (409,7 mg O2/L) que estão acima do limite permitido pela legislação. Em função disso, os processos oxidativos avançados (POA´s) surgem como alternativa para o seu pré-tratamento. O foco principal desse trabalho foi utilizar a aplicação da fotocatálise homogênea, empregando concomitantemente a luz solar com o reagente Fenton (H2O2 + Fe2+) num reator aberto com volume constante da amostra (3L) em sistema semi-batelada para verificar a eficiência do processo na remoção da carga orgânica. O reator solar possui um suporte de madeira que está direcionado ao Equador com um ângulo de inclinação de 23º, com uma placa metálica sem pigmentação denominada branco, numa vazão constante (13 L / min) em períodos com maior intensidade de radiação UV e monitorados pelo radiômetro. Após o ajuste do chorume de acordo com a planilha experimental, o volume do reagente Ferro (0,82 mol) foi adicionado totalmente no início da reação e o peróxido de hidrogênio (30% m/v) durante 30 min do tempo total de 1 hora, através de uma bureta dosadora, de maneira controlada que o peróxido de hidrogênio fosse consumido integralmente na reação de degradação, aumentando assim sua eficiência. O chorume tratado foi bombeado até a parte superior da placa, percolando-a uniformemente enquanto recebia a radiação solar sobre a placa. O processo fotocatalítico foi otimizado por um planejamento fatorial (23) com duplicata e triplicata no ponto central contendo 19 experimentos com variáveis de entrada: pH (3, 3,5 e 4) , quantidade de [H2O2] ( 73,2 g , 85,4 g e 97,6 g ) e quantidade de [Fe2+ ] (4,0 g , 5,0 g e 6,0 g ). As variáveis respostas do processo utilizadas foram: eficiência de remoção de COT (Carbono Orgânico Total) e DQO (Demanda Química de Oxigênio). As maiores reduções percentuais de DQO e COT, respectivamente, 89,19% e 86,12%, além do aumento de sua biodegradabilidade para 0,55 com um custo de R$ 0,3558 / 3L. Desta forma, o processo fotocatalítico mostrou grande viabilidade técnica e econômica em relação à degradação da carga orgânica de chorume. / The leachate used was fresh from the landfill of the city of Cachoeira Paulista in the state of São Paulo. Has a low ratio of biodegradability (BOD / COD = 0.094) demonstrated mainly through the analysis parameters characterizing the TOC (618,1 mg C / l) COD (mg O2 4345,88 / L) and BOD5 (mg O2 409,7 / L) that are above the limit allowed by law. As a result, the advanced oxidation processes (AOP\'s) are an alternative to their pre-treatment. The main focus of this work was to use the application of photocatalysis homogeneous, employing concurrently sunlight with Fenton\'s reagent (H2O2 + Fe2+) in an open reactor with constant volume of sample (3L) in the semi-batch to verify the efficiency of the process in removal of organic matter. The solar reactor has a wooden support that is directed to the equator with a tilt angle of 23 º, with a metal plate without pigmentation called white, a constant flow rate (13 L / min) in periods with higher UV intensity and monitored by radiometer. After adjusting the leachate according to the experimental sheet, the volume of reagent iron (0,82 mol) was added entirely at the beginning of the reaction and hydrogen peroxide (30% w / v) for 30 min to 1 hour total time through a dosing burette so controlled that the hydrogen peroxide was consumed entirely in the degradation reaction, thus increasing its efficiency. The treated leachate was pumped to the top of the plate evenly percolating while receiving the solar radiation on the plate. The photocatalytic process was optimized by a factorial design (23) with duplicate and triplicate center point experiments containing 19 input variables: pH (3, 3,5 and 4), the amount of [H2O2] (73,2 g, 85,4 g 97,6 g) and the amount of [Fe 2+] (4,0 g, 5,0 g and 6,0 g). The response variables of the process were: removal efficiency of TOC (Total Organic Carbon) and COD (Chemical Oxygen Demand). The largest percentage reductions of COD and TOC, respectively, 89,19% and 86,12%, besides increasing its biodegradability to 0,55 at a cost of R $ 0,3558 / 3L. Thus, the photocatalytic process showed great technical and economic feasibility in relation to the degradation of the organic leachate.

Page generated in 0.0804 seconds