• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 296
  • 17
  • 15
  • 15
  • 15
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 1
  • Tagged with
  • 315
  • 315
  • 76
  • 57
  • 56
  • 55
  • 53
  • 45
  • 35
  • 35
  • 30
  • 30
  • 29
  • 29
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Calibre vascular retiniano e a pressão arterial medida por monitoramento ambulatorial da pressão arterial

Pakter, Helena Messinger January 2010 (has links)
É bem conhecido que alterações vasculares iniciam como um processo silencioso e assintomático. A identificação precoce de anormalidades vasculares na retina em pacientes assintomáticos pode permitir a detecção de pacientes em risco de desenvolver DCV. Por prover visualização direta do leito vascular, a retina pode ser estudada não invasivamente mostrando o grau de acometimento da microcirculação. Avanços nas técnicas de fotografia retiniana e de análise digital de imagem tem permitido a mensuração objetiva de alterações vasculares da retina. Com isso, é possível quantificar anormalidades na microvasculatura retiniana, imprescindível para o estudo da fisiopatologia da hipertensão arterial sistêmica, bem como para a avaliação da associação com doença cardiovascular. Um software desenvolvido pela autora desta tese e colaboradores é capaz de medir calibre de arteríolas e vênulas de retinografias digitalizadas. Esse software, nomeado Retinal Analyser System (RAS), foi atualizado e houve a inclusão e testagem de um fator de escala ou calibração, apresentado no Artigo 1 dessa tese. Os métodos de análise de imagens da retina utilizados para medir calibre dos vasos retinianos não determinam exatamente o que está sendo medido. Assim, havia necessidade de investigar se o calibre medido no software RAS corresponde ao lúmen vascular somente ou se inclui a parede vascular. O Artigo 2 dessa tese apresenta a comparação de medidas de calibre de vasos retinianos, em retinografias coloridas com angiografias fluoresceínicas. Nesse artigo concluímos que, como as diferenças encontradas entre os dois métodos foram muito pequenas, o método microdensitométrico mede o lúmen vascular. Os calibres vasculares retinianos avaliados quantitativamente por métodos digitalizados tem mostrado uma associação significativa com incidência e gravidade da hipertensão arterial casual. No entanto, nas últimas décadas, tem sido discutido o valor da medida casual da pressão arterial para fins prognósticos. Em função da variação contínua da pressão arterial, de momento a momento, de acordo com as atividades do indivíduo, novos métodos podem complementar a avaliação através de medidas repetidas da pressão arterial, permitindo a detecção da pressão arterial usual. Tendo em vista essas considerações, o Artigo 3 dessa tese avaliou a associação entre os diferentes parâmetros da pressão arterial, medida pela MAPA, e os calibres vasculares retinianos. A relação entre pressão arterial e calibre arteriolar e venular da retina no momento da obtenção retinografia também foi estudada. Demonstramos que a pressão diastólica média das 24 horas, da vigília e do sono teve associação inversa e significativa com calibre arteriolar e razão arterio-venosa, mas não com calibre venular. A pressão arterial medida na hora da retinografia não mostrou associação com o calibre dos vasos retinianos. Assim concluímos que a associação entre o calibre arteriolar dos vasos retinianos e a pressão arterial não é influenciada pela variação instantânea da pressão arterial e, provavelmente, depende de lesões histológicas da parede arteriolar secundária à hipertensão sustentada. Através da MAPA também é possível avaliarmos a variação temporal da pressão arterial ao longo de um período de 24 horas, e assim estudar o ritmo circadiano e a ritimicidade da pressão arterial. Uma maneira de analisar a ritimicidade da pressão arterial é através do método Cosinor, um método de análise de regressão periódica, baseada na adaptação da função do coseno, para valores da pressão arterial com período de 24 horas. O método Cosinor gera, em cada elemento (indivíduo ou população), os seguintes parâmetros de validação do ritmo circadiano: MESOR (sigla em inglês para média do ritmo ajustada estatísticamente), acrofase e amplitude. O estudo do ritmo circadiano da pressão arterial, avaliado pela da análise de cosinor, e sua associação com os calibres vasculares retinianos, resultou no artigo 4 dessa tese. Nesse artigo, mostramos que o MESOR associa-se significativa e inversamente com calibre arteriolar, com uma magnitude de 0.8 a 1 micron de redução no calibre para um aumento de 10 mmHg do MESOR da pressão arterial. O calibre venular não mostrou associação com o MESOR. Também usamos a análise de Cosinor para população e avaliamos as diferenças nos ritmos da pressão arterial entre as populações do primeiro e dos demais quintis de calibre vascular. Através desta análise observamos que amplitude e acrofase da pressão arterial são estatisticamente diferente entre as populações do primeiro e demais quintis de calibre venoso, mas não arteriolar. Em resumo, enquanto o MESOR está associado ao calibre arteriolar, a amplitude e a acrofase estão associadas ao calibre venular. Concluindo, essa tese mostra, através de seus 4 artigos, a aplicação do software RAS para medida de calibres vasculares retinianos e a associação dessas medidas com pressão arterial, em uma população de pacientes hipertensos. A associação entre o calibre vascular retiniano, a pressão arterial medida 24 horas e o seu ritmo, demonstrada nessa tese, fortalece a hipótese que a avaliação da microvasculatura retiniana pode ser um marcador clínico importante de lesão em órgão. / It is well known that vascular changes begin as a silent and asymptomatic process. Early identification of retinal vascular abnormalities in asymptomatic patients may allow the detection of patients at risk. By providing unique visualization of the vascular bed, the retina can be studied no invasively and show the degree of microcirculation involvement. Advances in techniques of retinal photography and digital image analysis have allowed objective measurement of retinal vascular changes. Thus, it is possible to quantify abnormalities in the retinal microvasculature, essentially to study hypertension pathophysiology, and to assess its association to cardiovascular disease. Software developed by our research group is able to measure the caliber of arterioles and venules of digitized fundus. This software, named Retinal Analyzer System (RAS), has been updated by including and testing a scale factor, presented in Article 1 of this thesis. The current methods of image analysis used to measure the caliber of retinal vessels do not determine exactly what is being measured. Thus there was need to investigate whether the caliber measured in RAS software corresponds to the vascular lumen only or whether it includes the vascular wall. Article 2 of this thesis presents a comparison of the measurements of retinal vessels calibers in color fundus photography to those in fluorescein angiography. In this article we show that the differences found between the two methods were very small, and concluded that the microdensitometry method measures mainly the vascular lumen. The retinal vascular calibers measured quantitatively by microdensitometric methods have shown a significant association with incidence and severity of hypertension. However, studies evaluating these associations are based on casual blood pressure and, in recent decades, it has been discussed the value of casual blood pressure measurement. In light of continuous variation in blood pressure from moment to moment, according to the individual's activities, new methods can complement the assessments through repeated measurements of blood pressure, allowing the detection of usual blood pressure. Given these considerations, Article 3 of this thesis examined the association between different parameters of the blood pressure measured by ABPM, and retinal vascular caliber. The relationship between blood pressure at the time of retinography acquisition and retinal arteriolar and venular caliber was also studied. We show that the mean 24 hours, daytime and night time diastolic blood pressure were significantly and inversely associated with arteriolar caliber and arteriovenous ratio, but not with venular caliber. The pressure measured at the time of acquisition of the fundus showed no association with the caliber of retinal vessels, thus the association between arteriolar retinal vessels caliber and blood pressure is not influenced by instantaneous variation of blood pressure and probably depends of histological damage of arteriolar wall secondary to sustained hypertension. Using ABPM is also possible to evaluate the temporal variation of blood pressure over a period of 24 hours, and then study the circadian rhythm of blood pressure. One way to analyze the blood pressure rhythm is using the Cosinor method, a method of periodic regression analysis, based on the adaptation of the cosine function, for values of blood pressure with 24-hour period. The method Cosinor generates the following validation parameters of the circadian rhythm: MESOR (acronym for "Midline Estimated Statistic Of Rhythm"), acrophase and amplitude. The study of circadian rhythm of blood pressure, as assessed by analysis COSINOR and its association with retinal vascular caliber, resulted in Article 4 of this thesis. In this paper we show that MESOR is associated significantly and inversely with arteriolar caliber, with a magnitude of 0.8 to 1 micron reduction to an increase of 10 mmHg of blood pressure MESOR. The venular caliber was not associated with MESOR. We also use the Cosinor analysis to study differences in the rhythms of blood pressure among populations in the first quintile and the rest quintiles of vascular caliber. Through this analysis we found that amplitude and acrophase of blood pressure were statistically different between the populations of the first and the other quintiles of venous caliber, but not arterioles. In conclusion, this thesis shows, through its four articles, the application of RAS software to measure retinal vascular caliber and the association of these measurements with blood pressure in a population of hypertensive patients. The association between retinal vascular calibers, blood pressure measured 24 hours and rhythm, as demonstrated in this thesis, strengthens the hypothesis that assessment of the retinal microvasculature may be an important clinical marker of organ damage.
132

"Postura e controle postural: desenvolvimento e aplicação de método quantitativo de avaliação postural" / Posture and postural control: development and application of a quantitative method for postural evaluation

Ferreira, Elizabeth Alves Gonçalves 16 March 2006 (has links)
A avaliação postural é um método amplamente utilizado na fisioterapia para compreensão do alinhamento dos segmentos corporais e influencia diretamente na conduta terapêutica. A finalidade do alinhamento corporal é manter o corpo equilibrado, ou seja, projetar o centro de gravidade na base de sustentação, administrando assim, a força gravitacional. O objetivo deste estudo foi avaliar o alinhamento da postura, o controle postural e a correlação entre ambos, em adultos jovens e saudáveis entre 19 e 45 anos. Inicialmente foram avaliados 122 indivíduos, e após a análise de conglomerados foi selecionado, por similaridade, um grupo de 115 indivíduos, sendo 74,8% do gênero feminino com idade média de 25,96 ± 6,90 anos. O procedimento consistiu do preenchimento de protocolo de anamnese, colocação de marcadores em pontos anatômicos específicos, obtenção de fotografias em vista anterior, posterior, lateral direita e esquerda, avaliação do controle postural a partir do centro de pressão na plataforma de força e mensuração da base de suporte. A análise das fotos foi realizada com o software de análise postural (SAPO), desenvolvido conjuntamente com este estudo. Os dados foram submetidos à análise estatística descritiva, correlacional e fatorial. Foram identificados valores quantitativos para as variáveis de análise postural para os segmentos da cabeça, membros superiores, membros inferiores e tronco, bem como, a freqüência das inclinações para direita e esquerda. Para a cabeça, por exemplo, observou-se inclinação em 87,9% da amostra com predomínio à direita em 67%. Houve predomínio de inclinação do ombro e da pelve à direita respectivamente em 67,8% e 42,6% da população estudada. Os membros inferiores apresentaram alinhamento médio de 178 graus e o tronco predomínio de inclinação à direita em 66,1%. Não foi constatada correlação entre o controle postural e o alinhamento postural. Os dados sugerem que há um padrão de similaridade para o alinhamento postural, entretanto não se pode afirmar que a simetria postural seja este padrão. / The postural evaluation methodology is widely used in physiotherapy to understand the alignment of body segments and to guide the therapeutic approach. Body alignment is meant to maintain the body balanced, or else to project the centre of gravity onto the base of support, hence managing the gravity force. The objective of this study was the evaluation of postural alignment, postural control and their correlation in young healthy adults, between 19 and 45 years of age. After a statistical clustering and similarity analysis, the initially 122 evaluated individuals were reduced to 115, of which 74.8% female with average age of 25,96 ± 6,90 years. The procedure included answering an anamnesis protocol, the placement of markers on specific anatomic points, taking front, back, right and left side pictures, evaluation of the postural control through the behaviour of the centre of pressure on a force plate and the measurement of the base of support. The pictures were analysed with help of the postural analysis software (SAPO), developed in collaboration with this study. Data were analysed using descriptive, correlative and factorial statistics. Quantitative values were identified for the postural analysis variables for the head, upper limbs, lower limbs and trunk segments, as well as the right-left inclination frequencies. For the head, as an example, 87.9% of the sample presented inclination, of which 67% to the right. The shoulder and the pelvis also presented a more frequent inclination to the right in 67,8% and 42,6% of the population respectively. The lower limbs presented an average alignment of 178º and the trunk presented a right inclination in 66,1% of the cases. No correlation between postural control and postural alignment was identified. Data suggest that there is a similarity pattern for the postural alignment, but it cannot be said that postural symmetry represents such pattern.
133

Elaboração e implementação de um plano de manutenção preditiva, preventiva e curativa na Lipor - Serviço Intermunicipalizado de Gestão de Resíduos do Grande Porto

Faria, Nuno André Cunha Correia de January 2013 (has links)
Trabalho realizado na Lipor, orient. Eng. Pedro Oliveira / Tese de Mestrado Integrado. Engenharia Industrial e Gestão. Faculdade de Engenharia. Universidade do Porto. 2013
134

Estudo da aplicação do CASE Oracle Designer/2000 ao projecto GIST

Paes, Dinis Manuel Alves da Mota Correia January 1999 (has links)
Dissertação apresentada para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores (Área de especialização em Informática Industrial), na Faculdade de Engenharia da Universidade do Porto, sob a orientação do Prof. Dr. João Bernardo de Sena Esteves Falcão e Cunha
135

Optimização de configuração de um projecto tipo para microgeração fotovoltaica

Viana, Filipe Manuel Mota Cunha January 2008 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores - Major Energia. Faculdade de Engenharia. Universidade do Porto. 2008
136

Sistema de aquisição e registo de variáveis cardíaco-respiratórias durante o sono

Carrilho, Daniel José Teixeira January 2001 (has links)
Dissertação apresentada para obtenção parcial do grau de Mestre em Engenharia Biomédica, na Faculdade de Engenharia da Universidade do Porto, sob a orientação dos Profs. Doutores Ana Maria Tomé e António Martins da Silva
137

Métodos computacionais de otimização / Computational methods of optimization

Ferraz, Bruna Alves [UNESP] 19 December 2017 (has links)
Submitted by Bruna Alves Ferraz (bruna.alves.ferraz@gmail.com) on 2018-01-12T12:56:17Z No. of bitstreams: 1 Dissertacao_BrunaAF.pdf: 1135818 bytes, checksum: 02e01c1ac05f20f13657b40ed7d959fe (MD5) / Rejected by Adriana Aparecida Puerta null (dripuerta@rc.unesp.br), reason: Prezada Bruna Alves Ferraz, Solicitamos que realize uma nova submissão seguindo as orientações abaixo: - Capa - Faltou a capa no documento enviado. Este item é elemento obrigatório de acordo com as normas de trabalhos do seu Programa de Pós Graduação e deve vir antes da Página de rosto. Agradecemos a compreensão e aguardamos o envio do novo arquivo. Atenciosamente, Biblioteca Campus Rio Claro Repositório Institucional UNESP on 2018-01-12T16:18:28Z (GMT) / Submitted by Bruna Alves Ferraz (bruna.alves.ferraz@gmail.com) on 2018-01-15T18:07:31Z No. of bitstreams: 1 Bruna Alves Ferraz.pdf: 1341591 bytes, checksum: 6e9837abd2a00d05c9ba70d843b7c4c2 (MD5) / Approved for entry into archive by Adriana Aparecida Puerta null (dripuerta@rc.unesp.br) on 2018-01-15T18:18:13Z (GMT) No. of bitstreams: 1 ferraz_ba_me_rcla.pdf: 1265910 bytes, checksum: 9b0bcbf17772b4ac87b8058427405948 (MD5) / Made available in DSpace on 2018-01-15T18:18:13Z (GMT). No. of bitstreams: 1 ferraz_ba_me_rcla.pdf: 1265910 bytes, checksum: 9b0bcbf17772b4ac87b8058427405948 (MD5) Previous issue date: 2017-12-19 / Neste trabalho discutiremos alguns métodos clássicos para otimização irrestrita, a saber o Método de Cauchy e o Método de Newton, e analisaremos a convergência desses métodos. Veremos que o Método de Cauchy, que faz a cada iteração uma busca unidirecional na direção de máxima descida, ou seja, na direção oposta ao gradiente, tem convergência linear. O método de Newton, por outro lado, minimiza, em cada iteração, a aproximação quadrática da função objetivo. Nos métodos de busca unidirecional é preciso minimizar uma função a partir de um certo ponto, segundo uma direção dada, que é a direção de busca. Por essa razão, estudaremos o Método da Seção Áurea, que fornece uma minimização exata de uma função real de uma variável real. / In this work we will discuss some classic methods for unrestricted optimization, namely the Cauchy Method and Newton’s Method, and we will analyze the convergence of those methods. We will see that the Cauchy Method, that realizes on each iteration a unidirectional search in the direction of maximum descent, that is, in the direction opposite to the gradient, has linear convergence. The Newton Method, on the other hand, minimizes, in each iteration, the quadratic approximation of the objective function. In unidirectional search methods, one must minimize a function from a certain point in a given direction, which is the search direction. For that reason, we will study the Golden Section Method, which provides the exact minimization of a real function of a real variable.
138

Estudo da resistência ao embutimento de pinos de aço em peças estruturais de madeiras de reflorestamento /

Pallarolas, Ernesto Abel Fernando Friedmann. January 2017 (has links)
Orientador: Julio Cesar Molina / Banca: Cristiane Inácio de Campos / Banca: Iuri Emmanuel de Paulo Ferreira / Resumo: Este trabalho teve a finalidade de estudar a resistência ao embutimento de ligações efetuadas por pinos metálicos (pregos) em peças estruturais de madeira. Para tanto foram consideradas três principais abordagens: analítica, numérica e experimental. Inicialmente foi efetuado um levantamento teórico sobre o tema, com base na literatura disponível, para avaliação da normalização nacional e internacional pertinente ao assunto. Na sequência foram realizados ensaios experimentais em corpos de prova compostos por madeiras de reflorestamento de pinus e eucalipto com ligações metálicas efetuadas por pinos metálicos com diâmetro de 6,5 mm. Os ensaios foram realizados de acordo com as recomendações das normas: brasileira ABNT NBR 7190:1997, europeia EUROCODE 5:2004 e americana ASTM D5764:2007 com posterior comparação entre os resultados obtidos para a resistência ao embutimento. Foi realizada uma análise estatística dos resultados obtidos, incluindo um estudo da resistência ao embutimento corrigida pela umidade e pela densidade. Foram calculados os valores analíticos teóricos de resistência ao embutimento mediante fórmulas propostos por cada norma e comparadas às médias dos valores experimentais obtidos pelas mesmas. Foi proposta também a análise do valor ideal de resistência por meio de métodos de análise de regressão segmentada sobre as curvas de comportamento de resposta do material. Por fim foram realizadas simulações numéricas no software ABAQUS, que tem como base o Método dos El... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work had the purpose of studying the embedment resistance of connections made by metallic pins (nails) in structural pieces of wood. For that, three main approaches were considered: analytical, numerical and experimental. Initially, a theoretical survey was carried out on the subject, based on available literature, for the evaluation of national and international standardization related to the subject. Experimental tests were carried out on test specimens composed of pine and eucalyptus reforestation woods species with metal connections made by pins with a diameter of 6.5 mm. The tests were carried out according to the recommendations of Brazilian ABNT NBR 7190:1997, European EUROCODE 5:2004 and American ASTM D5764:2007 standards for further comparison between the obtained results for the embedment resistance. A statistical analysis of the obtained results was carried out, including a study of the resistance corrected by the humidity and the density. The theoretical analytical values of resistance were calculated using formulas proposed by each standard and compared to the averages of the experimental values. It was also proposed the analysis of the ideal resistance value by segmented regression analysis methods on the curves of the embedment behavior data set generated by the standards. Finally, numerical simulations were performed in ABAQUS software, which is based on the Finite Element Method (MEF) to evaluate the stress distributions in the bond areas. The obtained results showed that there are significant divergences between the experimental values of resistance obtained through the studied standards when compared to each other. They also show that the analytical calculated values overestimate the experimental resistance for all studied standards. Also, that the strength corrected by the density presents better dispersion perform quality for the studied data set. It is concluded that the studied / Mestre
139

Uma plataforma para manuseio, análise e avaliação de dados de observação e controle de simulações

Sidou, Pedro Niederhagebock January 2017 (has links)
Atualmente, com a melhoria das técnicas de paralelização, cada vez mais vem sendo empregado o uso de clusteres de computadores para programas exigentes de alta performance. Porém, para um programa rodar adequadamente em paralelo, o mesmo deve ser escrito de maneira paralelizável. A proposta deste trabalho é o desenvolvimento de uma plataforma computacional que facilite a escrita de programas orientados à análise de dados climáticos e simulações de fenômenos atmosféricos escritos em paralelo. A plataforma foi pensada de maneira a ser o mais exível possível, permitindo que novas funcionalidades sejam adicionadas através de plugins. Em um futuro próximo, pretende-se disponibilizá-la para uso público com licença GNU General Public License (GNU GPL) e código aberto. Para demonstrar seu potencial de uso, foi realizado um estudo exploratório com dados provenientes do projeto de reanálise Twentieth Century Reanalysis version 2 (20CRv2). Tal estudo visa obter informações sobre que parâmetros e escalas de tempo são importantes para a descrição do fenômeno da zona de convergência do Atlântico sul (ZCAS). / Since parallel computing technologies are improving very fast, computer clusteres are getting more and more employed for highly demanding computational tasks. Nevertheless, for a software to run in a cluster, it needs to be written in a parallel way, which is not necessarily a simple task. Therefore, the aim of this work is to develop a computer platform capable of manipulating, analysing and evaluating climate observational data and controlling simulation in a parallel manner. Features can be added to the platform through plugins, making it very exible and extensible for a very large range of tasks. A simple application is purposed to demonstrate the platform's potential uses. The application consists of a exploratory study of data from the 20th century reanalysis project concerning the South American Convergence Zone (SACZ), a very important phenomena in the south hemisphere.
140

Uma contribuição ao controle de qualidade de gamacâmeras

Oliveira, Fernanda Ramos de January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T00:42:30Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T18:38:05Z : No. of bitstreams: 1 175067.pdf: 3456208 bytes, checksum: 81c6abceeb748b3ef6355799a0e6e6c2 (MD5) / A verificação da linearidade e da resolução intrínseca de gamacâmeras é feita através da análise da imagem de um fantoma de barras (dispositivo padrão proposto por norrnas para realização deste teste). Este trabalho propõe que a imagem seja digitalizada, através de um scanner específico para filmes radiográficos, e avaliada através de um programa de computador. A sistemática proposta não exige que nenhum equipamento ou dispositivo complementar seja acrescentado à gamacâmera. Apenas a imagem, obtida segundo os procedimentos já previstos da norma, é analisada pelo computador. Isto permite a aplicação da sistemática a qualquer serviço de medicina nuclear. 0 programa foi avaliado quanto à sua repetitividade, sensibilidade ao posicionamento e alinhamento da imagem, aos parâmetros do sistema de digitalizagiio (scanner), do forrnato de compactação das imagens e número de imagens envolvidas. Também foi feita uma comparação entre a resolução intrínseca obtida através do método proposto pela CNEN, na norma CNEN-NE-3.05, e pelo programa criado.

Page generated in 0.4188 seconds