• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo comparativo de quatro materiais e de duas técnicas, simples e dupla, para moldagens funcionais em prótese total

Marchezan, Walter January 2004 (has links)
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
12

Resistência à fratura de próteses parciais fixas de zircônia : efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos /

Campos, Fernanda. January 2012 (has links)
Orientador: Marco Antonio Bottino / Coorientador: Rodrigo Othávio de Assunção e Souza / Banca: Luiz Felipe Valandro Soares / Banca: Liliana Gressler May / Resumo: Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator "tratamento da cerâmica de infraestrutura" (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA - RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor "treatment of infrastructure ceramic"(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below) / Mestre
13

Efeito protetor da vitima E(ɑ-TOCOFEROL) contra a atividade citotóxica do peróxido de hidrogenênio

Vargas, Fernanda da Silveira [UNESP] 05 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-05Bitstream added on 2014-06-13T18:35:09Z : No. of bitstreams: 1 vargas_fs_me_arafo.pdf: 600635 bytes, checksum: c88f9eb602669098e457e9ab4722d46a (MD5) / O clareamento dental de consultório, realizado com géis que apresentam elevada concentração de peróxido de hidrogênio (PH), pode causar danos intensos para as células da polpa dentária. Dentro deste contexto, a administração de agentes antioxidantes previamente ao clareamento dental, tem sido considerada uma terapia promissora, pois pode eliminar ou pelo menos minimizar os efeitos adversos deste procedimento clínico estético. Assim, o objetivo do presente estudo foi avaliar o possível efeito protetor da Vitamina E (alfa-Tocoferol / α-T) contra à ação citotóxica do PH sobre células odontoblastóides (MDPC-23). Para isto, células foram semeadas em placas de 96 wells durante 72 horas e então submetidas a diferentes tempos de pré-tratamento (1, 4, 8 e 24 horas) com variadas concentrações de α-T (1, 3, 5 e 10 mM). Após os períodos de pré-tratamento, as células foram expostas ou não ao PH (0,018%) durante 30 minutos. Nos grupos controle positivo e negativo, as células foram somente expostas a uma solução de PH (0,018%) ou meio de cultura, respectivamente. O metabolismo celular foi avaliado pelo teste de MTT. A absorbância foi transformada em porcentagem e analisada pelo Teste de Kruskal-Wallis, complementado por Mann-Whitney (α=0,05%). Todas as concentrações de α-T e tempos de pré-tratamento propostos neste estudo apresentaram proteção das células contra os efeitos citotóxicos do PH. Porém, os melhores resultados foram obtidos com as concentrações de 1 e 3 mM (126% e 97%, respectivamente) por 24 horas em relação a 41% de metabolismo celular do grupo controle positivo (p<0,05). Portanto, as células pré-tratadas com α-T por 24 horas, em concentrações baixas (1 e 3 mM), apresentaram os melhores resultados de viabilidade celular, ou seja, maior efeito protetor frente à agressão direta do PH / The in-office tooth bleaching using gels with high concentrations of hydrogen peroxide (HP) may cause irreversible damage to pulp tissue. Therefore, the administration of antioxidazing agents previously to the tooth bleaching procedures has been considered as a promising therapy, mainly due the capacity of these agents to prevent, or at last reduce, the negative side-effects caused by toxic products used in this esthetic treatment. Therefore, the aim of the present in vitro study was to evaluate the protective activity of vitamin E (alfa-Tocoferol / α-T) against the toxic effects of HP applied to cultured odontoblast-like cells (MDPC-23). Cells were seeded in wells of 96-well plates for 72 hs and then pre-treated with different concentrations of α-T (1, 3, 5, and 10 mM) for variable periods (1, 4, 8, and 24 hs). Following, the cells were exposed to a HP solution (0,018%) for 30 min. In positive and negative control groups, the cells were exposed only to HP solution (0,018%) or culture medium, respectively. The cell metabolism was assessed by MTT assay and the absorbance numeric data, expressed as percentage values, were subjected to the statistical analysis of Kruskal-Wallis complemented by Mann-Whitney test (α=0.05%). All α-T concentrations and pre-treatments evaluated in this study showed cell protection against the cytotoxic effects of HP. However, considering the MDPC-23 cells in the negative control group as presenting 100% metabolism, it was observed that the most relevant data occurred when the cells were pre-treated with α-T at 1 and 3 mM (126% and 97% of cell metabolism, respectively) for 24hs compared to the positive control group (41%) (p<0.05). Based upon the methodology used in the present investigation, it can be concluded that low concentrations of α-T (1 and 3 mM) applied for 24 hs to the cultured odontoblast-like MDPC-23 cells provide the best protective effects against the cytotoxicity caused by hydrogen peroxide
14

Resistência à fratura de próteses parciais fixas de zircônia: efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos

Campos, Fernanda [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 campos_f_me_sjc.pdf: 579878 bytes, checksum: 4caa0be77bfe4184e9b5b180d03e5a22 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator “tratamento da cerâmica de infraestrutura” (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA – RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... / This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor “treatment of infrastructure ceramic”(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below)
15

Continuação dos estudos sobre alterações dimensionais, de resistência à tração e de resistência ao dobramento, em corpos de gesso, consequente à sua fratura, seguida de colagem /

Springmann, Werner January 1975 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-15T19:36:44Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T13:06:37Z : No. of bitstreams: 1 141692.pdf: 4792738 bytes, checksum: af8908cc1e529c5c629472ae7ab3d4b9 (MD5)
16

Relação entre gênero e forma dos incisivos centrais superiores

Brunetto, Juliana 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T08:32:27Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T20:35:46Z : No. of bitstreams: 1 281255.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / A seleção do formato mais apropriado para os dentes anteriores superiores é uma etapa importante para obtenção de estética em próteses dentárias. A associação entre forma dentária e gênero tem sido empregada para auxiliar esta seleção, considerando-se que dentes femininos são mais arredondados e que dentes masculinos são mais quadrangulares. Entretanto, tal relação ainda carece de respaldo científico. O objetivo deste estudo foi avaliar, in vivo, possíveis relações entre gênero (masculino e feminino) e os formatos dentários triangular, quadrangular e ovóide. A partir de uma população de estudantes da primeira série do ensino médio da Rede Estadual de Ensino de Florianópolis - Santa Catarina (Brasil), com faixa etária média de 15 anos, foi selecionada uma amostra contendo 433 estudantes. Foram realizadas fotografias do dente incisivo central superior direito de tais indivíduos. O elemento dentário 11 foi padronizado em todas as imagens fotográficas, por meio do sofware Adobe Photoshop, para deixar o longo eixo dentário na posição vertical. O formato geométrico de tais dentes foi determinado por meio de análise gráfica (objetiva) no software AutoCAD. Cada imagem foi classificada em uma das seguintes formas: quadrangular, oval ou triangular. No gênero feminino, os formatos foram 57,73% (n=127) ovóides, 23,54% (n=52) triangulares e 18,64% (n=41) quadrangulares, enquanto no gênero masculino, os formatos foram 54,93% (n=117) ovóides, 36,15% (n=77) triangulares e 8,92% (n=19) quadrangulares (p=0,0010). Em ambos os gêneros, o formato predominante é o ovóide, em proporções semelhantes. Entretanto, o formato triangular é mais frequente no sexo masculino do que no feminino, e o quadrangular mais frequente no sexo feminino do que no masculino.
17

Avaliação da liberdade rotacional de pilares hexágono externo e interno em três estágios

Ribeiro, Cleide Gisele January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T13:39:37Z (GMT). No. of bitstreams: 1 233578.pdf: 3361852 bytes, checksum: 88b9ea639fe7af6c5204b70b72dbe1a3 (MD5) / Uma das principais causas do alto índice de afrouxamento de parafusos em prótese sobre implante é a presença de uma maior liberdade rotacional na interface implante/pilar. O objetivo deste estudo foi avaliar a influência dos vários procedimentos laboratoriais sobre a liberdade rotacional e realizar uma análise comparativa entre pilares de hexágono externo e interno. Pilares do tipo UCLA com base metálica em cromo-cobalto foram divididos em : grupo A (pilares de hexágono externo) e grupo B (pilares de hexágono interno). Os valores da liberdade rotacional para os pilares de hexágono externo não variaram significativamente, enquanto que no grupo dos pilares de hexágono interno, os valores aumentaram significativamente após a aplicação do porcelana. Os pilares de hexágono interno apresentaram maior liberdade rotacional que os de hexágono externo.
18

Avaliação de diversos tipos de transferentes para prótese sobre implante

Andrade, Pâmela Cândida Aires Ribas de January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T17:57:10Z (GMT). No. of bitstreams: 1 327225.pdf: 4476966 bytes, checksum: 9afe1770eacf4599c637b70373a02e3d (MD5) Previous issue date: 2014 / A reprodução precisa da posição tridimensional (3D) do implante é um fator decisivo no estabelecimento de uma prótese ajustada e passiva. Vários fatores podem influenciar na precisão de uma moldagem de transferência sobre implante, e o desenho do transferente pode ser um deles. OBJETIVO: O objetivo deste estudo foi analisar quatro desenhos diferentes de transferente e comparar a precisão da moldagem de transferência de implantes unitários realizada por eles. MATERIAL E MÉTODOS: Um modelo metálico com quatro implantes hexágono externo foi desenhado e fabricado para a realização de vinte moldagens pela técnica da moldeira aberta. As moldagens foram realizadas com todos os tipos de transferentes (n=10) (transferente convencional [TC], transferente modificado com dois parafusos laterais [TMP], transferente modificado e sem parafusos laterais [TM], transferente modificado com resina acrílica [TR]); e duas situações (S1: n=20 e S2: n=20) de espaço 3D envolvendo dente e implante também foram avaliadas. As moldagens foram vazadas com gesso especial tipo IV e a precisão da posição 3D dos análogos foram avaliadas utilizando uma Máquina de Medir por Coordenadas (MMC). As medições (deslocamento linear, angular e rotacional) foram comparadas com as medições calculadas no modelo metálico. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e pelo teste t de student. RESULTADOS: Os resultados mostraram que (1) não existiu diferença estatisticamente significante entre os diferentes tipos de transferente para as duas situações analisadas; e (2) na comparação entre S1 e S2 o TC deslocou e rotacionou na S2. CONCLUSÃO: A partir dos resultados deste estudo foi possível concluir que, estatisticamente, o tipo de transferente não influencia na precisão da moldagem de implante unitário. No entanto, o TC, na S2, aonde existiu maior quantidade de material de moldagem, apresentou alteração de posição.<br>
19

Influência dos fatores locais na prevalência da peri-implantite ao redor de implantes pilares de próteses totais fixas

Schuldt Filho, Guenther January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T09:48:06Z (GMT). No. of bitstreams: 1 304705.pdf: 13802930 bytes, checksum: e7dccfe8d948661bd94ee0c5e41f1cf9 (MD5) / Objetivo: A proposta deste estudo foi avaliar a influência dos fatores locais na prevalência da peri-implantite em implantes osseointegrados instalados na mandíbula e maxila de pacientes que utilizavam próteses totais implantossuportadas. Materiais e Métodos: Foram examinados 27 pacientes (161 implantes) que apresentavam implantes cilíndricos, conexão do tipo hexágono externo (Conexão, São Paulo, Brasil), radiografias mensuráveis, informações dos prontuários preenchidas adequadamente e próteses totais implantossuportadas aparafusadas. Para este estudo, nenhum dos pacientes havia sido submetido à algum tipo de visita para manutenção da prótese e dos implantes no CEPID. Foram coletadas informações com relação ao sexo, idade, hábitos tabagistas, histórico de doença periodontal e saúde geral do paciente antes e após a instalação dos implantes. Com relação aos implantes, coletaram-se informações referentes às suas características tais como localização, posicionamento, tempo em função, quantidade de mucosa ceratinizada, profundidade de sondagem, índice de sangramento do sulco modificado, tipo de carga, índice de placa modificado, sangramento à sondagem, recessão e distância entre implantes. Com relação à prótese, os dados coletados estavam relacionados à dificuldade de higienização, tipo de pilar utilizado, presença ou não de pilar protético e extensão do cantiléver. Resultados: Dos 161 implantes analisados, 116 (72%) apresentaram-se sem peri-implantite enquanto que 45 (28%) apresentavam a doença. Houve significância estatística (p < 0.05) com relação à localização - implantes instalados na maxila possuem 2.98 vezes mais chances de apresentarem peri-implantite. Assim como os pacientes com idade ? 60 anos tem 3.24 vezes mais chances de apresentarem este tipo de doença. Outra análise com relevância estatística (p < 0.05) foi a de que se não obedecida a distância de no mínimo 3 mm entre implantes, as chances do surgimento da doença aumentam em 2.98 vezes. Não houve relevância estatística em nenhuma das outras análises. Conclusão: Conclui-se que pacientes com idade ? 60 anos possuem maior propensão à peri-implantite assim como implantes instalados na maxila e aqueles com distância entre sim < 3 mm. / Objective: The purpose of this study was to evaluate the influence of local factors in peri-implantis' prevalence in osseointegrated implants installed either on mandible or maxilla of patients using full-arch prostheses. Materials and Methods: There were examined 27 patients (116 implants) that presented cylindric implants with external hex connection (Conexão, São Paulo, Brasil), radiographs, charts filled correctly and screwed full-arch prostheses. For this study, none of the patients attended any follow-up visit until the data collection. There were collected information regarding gender, age, smoking habits, periodontal disease historic and patient's general health before and after implants installation. In relation to the implant, information obtained were about its characteristics, positioning, time in function, bleeding on probing, width of keratinized mucosa, modified sulcus bleeding index, type of loading, modified plaque index, probing depth, recession and distance between implants. Considering full-arch prostheses, the data collected were related with hygiene difficulty, type of abutment, abutment presence or not and cantilever extension. Results: Of the 161 implants analysed, 116 (72%) showed no peri-implantitis whereas 45 (28%) presented signs and symptoms of the disease. There was statistical significance (p < 0.05) regarding implant positioning - implants installed in the maxilla are 2.98 times more likely to develop the disease. As well as patients aged = 60 years old are 3.24 times more likely of presenting peri-implantitis. Another analysis with statistical relevance (p <0.05) was that implants with less than 3mm between them, are 3 times more likely of having peri-implantitis. There was no statistical relevance considering the other analyses. Conclusion: It can be concluded that patients aged = 60 years have more chances of presenting peri-implantitis as well as implants positioned in the maxilla and those installed with distance between them < 3 mm.
20

Critérios endodônticos e protéticos a serem considerados na confecção de núcleos metálicos fundidos em dentes unirradiculares

Kauling, Ana Elisa Colle January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T23:36:59Z (GMT). No. of bitstreams: 1 315071.pdf: 974822 bytes, checksum: b57bfddbe4aa266ecc80c92d03b8aab2 (MD5) / Grande parte de dentes tratados endodonticamente necessitam de retentores intrarradiculares para viabilizar a restauração protética. Em caso de amplas destruições coronais utilizamos os núcleos metálicos fundidos (NMF) como retentores, ainda que o sucesso desta técnica seja questionável. O objetivo deste estudo retrospectivo foi analisar radiograficamente características endodônticas e protéticas que estão envolvidos na confecção de NMF, a fim de identificar os motivos que levam ao insucesso da técnica. Para isso foram selecionadas 500 radiografias periapicais digitais de dentes unirradiculares restaurados com NMF onde se analisou através de um software de mensuração (ImageJ, EUA) critérios endodônticos e protéticos. Nos critérios endodônticos avaliou-se a presença de endodontia (94,6%)*, ausência de lesão (67,2%)*, comprimento do material obturador (78,6%)*, distância entre o material obturador e o vértice dentário (69,4%)* e ausência de espaços vazios no remanescente obturador (49,4%)*. Já nos critérios protéticos avaliou-se o comprimento do pino (25,6%)*, relação do pino com a crista óssea (85,4%)*, diâmetro do pino (78,4%)*, ausência de espaços vazios entre remanescente obturador e pino (41%)* e pino contíguo ao conduto radicular (88,4%)*. Concluiu-se que muitos critérios endodônticos e protéticos são negligenciados durante a confecção de NMF, nos levando a crer que não é a técnica que falha, mas sim a utilização inadequada da mesma.

Page generated in 0.0468 seconds