• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Dispositivo para instalação de pilares protéticos angulados em implantes dentários

Oderich, Elisa January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-23T00:23:17Z (GMT). No. of bitstreams: 1 252697.pdf: 5504002 bytes, checksum: 9ece4ac202f0a0112aee5c178f67c5f2 (MD5) / A correta instalação de pilares protéticos angulados em implantes dentários é um procedimento clínico complexo e fundamental para o sucesso das próteses implantossuportadas. Visando simplificar tal procedimento foi desenvolvido um adaptador para este tipo de pilar. Objetivou-se com este estudo avaliar o desempenho deste novo dispositivo para instalação de pilares angulados. Dois métodos de instalação, com e sem o uso do adaptador, foram avaliados quanto ao tempo despendido para a instalação dos pilares, bem como as respostas oriundas do preenchimento de questionário específico por 40 profissionais experientes. O pilar angulado, entre os demais componentes protéticos, foi considerado aquele mais difícil de ser instalado. O tempo de instalação do pilar angulado com a utilização do adaptador é equivalente a 56,1% do tempo desprendido para realizar tal procedimento de maneira convencional. O uso do adaptador mostrou facilitar e reduzir significativamente o tempo de instalação dos pilares angulados. One of the complex clinical procedure on implant therapy is to install angled abutments. In order to simplify such procedure an appliance was developed by Dental Implant Research and Study Center - CEPID in Federal University of Santa Catarina - UFSC. The aim of this article was to assess the performance of this new device at installing pre-manufactured angled abutments. Two methods of angled abutment placement were tested in mannequin through time control by 40 experienced professionals. Among all the prosthetic components available, the angled abutment is the most difficult to be installed The angled abutment placement time with the appliance is 56.1% of that time necessary to realize this procedure by the conventional method. The appliance did facilitate and reduce angled abutment placement time.
32

Simulação trimensional da remodelação óssea em torno de próteses de quadril

Dallacosta, Darlan January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-23T03:45:11Z (GMT). No. of bitstreams: 1 248381.pdf: 2532401 bytes, checksum: 1b8b3c1967ff8744d2ef26525a08dd5a (MD5) / Nos modelos de simulação de adaptação óssea encontrados na literatura, pouco se observa sobre os efeitos de acoplamento entre o fenômeno de adaptação da interface e a remodelação interna do osso. No presente trabalho, uma formulação da adaptação óssea em torno de próteses que conjuga a evolução da interface osso-implante com as alterações das propriedades mecânicas do osso é extendida e modificada para ser aplicada a exemplos de sistemas osso/implante 3D. O comportamento interfacial evolutivo é modelado com o emprego de elementos de interface do tipo gasket que apresentam comportamento desacoplado nas direções normal e tangencial. Na direção normal, a lei constitutiva empregada é não linear e depende da densidade óssea e de um parâmetro mecânico local. Este parâmetro controla a formação de tecido ósseo (osteogênese) ou tecido fibroso (fibrogênese) para cada ponto da interface, além de permitir que ambos tecidos estejam presentes em quantidades relativas em um mesmo local interfacial. Para a adaptação mecânica que ocorre fora da região de interface, o modelo utiliza a hipótese de ótima estrutura óssea, com a distribuição de densidade óssea sendo obtida a partir da minimização da energia de deformação total da estrutura. O modelo de material para o tecido ósseo é obtido através do método da homogeneização, com o osso trabecular idealizado como uma microestrutura de repetição periódica.
33

Avaliação das próteses fixas totais sem estrutura metálica, implantossuportadas com carga imediata

Cunha, Hiron Andreaza da 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2008 / Made available in DSpace on 2012-10-24T00:37:30Z (GMT). No. of bitstreams: 1 269710.pdf: 1134622 bytes, checksum: d50293ec4a3817531c6d02ee4992e1b5 (MD5) / Por meio deste estudo foi analisado o comportamento clínico das próteses fixas implantossuportadas sem infra-estrutura metálica submetidas à carga imediata, como tratamento definitivo, em dez pacientes que receberam cinco implantes na mandíbula entre os foramens mentual, somando um total de 50 implantes, cada paciente recebendo uma prótese fixa de 12 elementos sem infra estrutura metálica e uma prótese total superior. Este estudo avaliou ao mesmo tempo a estabilidade inicial e secundaria dos implantes por um período de 24 meses, por meio do Osstell, aparelho que afere a estabiliade do implante por meio de freqüência de ressonância. Os resultados da análise descritiva apresentaram em média uma estabilidade inicial de 71.76 ISQ (Quociente de estabilidade do implante), a estabilidade secundária em média após 6 meses foi de 69,35 ISQ, 12 meses foi de 70.14 ISQ e 24 meses foi de 70.10 ISQ (Quociente de estabilidade do implante), indicando que os implantes estavam estáveis após 24 meses em função. Os resultados são favoráveis aos itens avaliados, não houve fraturas das próteses, não houve afrouxamento ou fraturas dos parafusos de retenção, não houve perda de implantes de nenhum dos cinqüenta implantes instalados, demonstrando ser viável o uso dessa técnica. / This study analyzed the clinical behavior of the implants, submitted to a immediate loading with fixed prosthesis implantsupported without a metallic infrastructure by means of Osstell, for a period of twenty-four months, in ten patients, who received five implants in the mandible between the mentonian foramens, with a total of 50 implants, each patient received a fixed prosthesis of 12 elements without a metallic structure and a superior total prosthetics. During this period it was also evaluated the clinical behavior of the prosthesis, as to the resistance to fracture of the acrylic resin, the unscrewing and fracture of the retention screws of the prosthesis in the masticating function. The results of the descriptive analysis presented an initial stability of 71.76 ISQ (Implant Stability Quotient). The secondary stability, after 6 months, was of 69,30 ISQ; 12 months, was of 68.04 ISQ; after 24 months, was of 69.48 ISQ, indicating that the implants were stable after 24 months of function. There were no losses of implants during this period. The results were favorable to the evaluated items, the initial and secondary stability remained in normal values, and there were no fractures of the prosthesis, no loosening or fractures of the retention screws, there were no losses of the fifty implants installed, during the period of study of 24 months, showing a viable use of this technique.
34

Tratamento do enfisema pulmonar por meio de implante broncoscópico de válvulas unidirecionais : análise das alterações funcionais

Oliveira, Hugo Goulart de January 2004 (has links)
Fundamentação. A doença pulmonar obstrutiva crônica (DPOC) é um problema de saúde pública prevalente que acomete aproximadamente 15% da população acima dos 40 anos, sendo a quarta causa de morte entre todas as doenças. No ano de 2001, foram registradas no Brasil 243.865 internações hospitalares, com gastos de R$ 105 milhões e 10.325 óbitos decorrentes dessa patologia. Enquanto não for alcançado maior sucesso nas campanhas antitabagismo, pouco se espera no que diz respeito à mudança desse panorama. A DPOC compreende a presença dos componentes de bronquite crônica e de enfisema. Ao paciente com DPOC e predomínio de enfisema, restam poucas terapêuticas médicas quando a doença é diagnóstica em fase avançada, sendo a reabilitação pulmonar ainda o recurso melhor estabelecido para o tratamento desses pacientes. A cirurgia redutora de volume pulmonar (CRVP), surgida em 1950, permanece como um procedimento cirúrgico maior, com morbidade e mortalidade significativas e aplicável a apenas um grupo restrito de pacientes. Objetivos. O uso de válvulas unidirecionais implantadas através de broncoscopia em brônquios segmentares tem por objetivo melhorar o funcionamento do sistema respiratório pulmonar por meio do redirecionamento do ar, redução do espaço morto, redução do volume pulmonar e amenização da hiperinsuflação dinâmica. Pacientes e métodos. Neste estudo foram tratados 19 pacientes com enfisema grave no período de junho de 2002 a outubro de 2004. O acompanhamento por até 24 meses incluiu exames de imagem, provas de função pulmonar, questionários de qualidade de vida, gasometria arterial e avaliações broncoscópicas. Resultados. Não houve pneumonia obstrutiva em nenhum dos 64 segmentos tratados; a principal complicação relacionada ao procedimento foi a presença de granuloma nos segmentos tratados (sem repercussão clínica); houve tendência de melhora nos parâmetros funcionais mantidos em até 24 meses e melhora significativa em até 6 meses em diversos parâmetros de qualidade de vida aferidos por questionários validados. Conclusão. Implantes broncoscópicos de válvulas unidirecionais constituem-se em uma contribuição ao tratamento do enfisema pulmonar.
35

Desenvolvimento de um método para montagem do sistema osso-prótese em modelos computacionais da artroplastia total do joelho

Oliveira, Henrique Rodrigues January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:57:41Z (GMT). No. of bitstreams: 1 331663.pdf: 14347462 bytes, checksum: 2821868a775b30b34c0063f9f24fdbe4 (MD5) Previous issue date: 2014 / Desde a primeira artroplastia do joelho bem sucedida, em 1861, vários estudos vêm ajudando engenheiros e ortopedistas na melhoria das técnicas cirúrgicas e no projeto de instrumentos e implantes. Neste contexto, este trabalho vem contribuir com o desenvolvimento de um método que oriente a construção e o alinhamento de um modelo computacional (ossos-próteses) para estudos comparativos da articulação do joelho após uma cirurgia de Artroplastia Total do Joelho (ATJ). O método, quando aplicado na construção do modelo, atende às necessidades de cirurgiões e engenheiros ao fornecer uma ferramenta capaz de simular, mensurar e avaliar precisamente (quando comparada aos métodos experimentais) parâmetros biomecânicos e, assim, facilitar o desenvolvimento das técnicas cirúrgicas e do projeto de próteses de ATJ. O trabalho engloba todos os tecidos ósseos que compõem os membros inferiores e os tecidos moles mais atuantes na articulação patelofemoral: o ligamento patelar, o tendão patelar e o músculo quadríceps, bem como os componentes protéticos de ATJ. Além do método para a construção e o alinhamento da montagem ossos-próteses parametrizada, de acordo com um procolo cirúrgico de ATJ, o trabalho aborda, em paralelo ao método, a modelagem paramétrica do conjunto de implantes do tipo Movimento Guiado. Como forma de demonstrar algumas aplicações do método desenvolvido, foram realizados dois estudos de caso. O primeiro estudo compara o posicionamento do componente femoral com relação ao fêmur após dois protocolos cirúrgicos diferentes de ATJ. O segundo, já utilizando o modelo de corpos rígidos, faz avaliação estática das forças do contato patelofemoral em seis ângulos diferentes de flexão, reproduzindo um agachamento.<br> / Abstract : Since the pioneering knee arthroplasty has proven to be successful in 1861, a number of studies have been helping engineers and orthopaedists in order to improve surgical techniques and the design of devices and prosthesis. This paper aims to contribute to the development of a method which will guide the construction and alignment of a computational model (bone-prosthesis) targeting a comparative study after a total knee arthroplasty (TKA). This method, once applied in the model construction, is supposed to fulfill the needs of surgeons and engineers providing a tool capable of simulate, measure and evaluate more accurately (when compared to experimental methods) the biomechanical parameters in question, facilitating the development of surgical techniques, as well as the design of TKA prostheses. The applied method encompasses not only all lower limbs bone tissues, but also the patellofemoral joint soft tissues: patellar ligament, patellar tendon and quadriceps muscle, along with guide motion TKA prostheses components. Besides the method of parametric construction and alignment of bone-prosthesis assembly, in accordance with a TKA surgical protocol, this work proposed also, in parallel to the method, a parametric modeling to TKA prosthesis, of guide motion model. As a way to demonstrate some of the applications of the method being developed, two case studies were carried out. The first case compares the position of the femoral component relative to the femur after two different surgical protocols in TKA. The second case uses the rigid body model in order to evaluate statically the patellofemoral contact force considering six different flexion angles, replicating the movement of squatting.
36

A percepção do cirurgião dentista quanto ao tipo de infraestrutura utilizado em próteses unitárias implantossuportadas

Melo, Eduardo Vilain de January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T09:41:12Z (GMT). No. of bitstreams: 1 304953.pdf: 1294497 bytes, checksum: d1f4940f51ab0956e463d12142ccb9a6 (MD5) / Objetivos: Avaliar a percepção de cirurgiões-dentistas pós-graduados nas áreas de periodontia, implantodontia, dentística restauradora e prótese dentária, em diagnosticar qual tipo prótese (cerâmica ou metalocerâmica) foi utilizada na reabilitação protética, em implantes unitários na região dos incisivos laterais superiores. Materiais e Métodos: Cinco implantes unitários na região do incisivo lateral superior foram restaurados, com dois tipos de próteses parafusadas diretamente sobre o implante (próteses metalocerâmica e cerâmica). Foram realizadas fotografias de ambas as próteses em posição, totalizando 10 imagens, que foram apresentadas a 40 avaliadores. Estes foram divididos em 5 grupos, de acordo com a área de especialidade (Pós-graduados em Dentística/Prótese Dental ou Periodontia/Implantodontia) e tempo de formado em odontologia (maior ou menor que 10 anos). Os avaliadores tinham de responder se a prótese era: cerâmica, metalocerâmica ou que não sabiam dizer. Resultados: Os Grupos 1, 3, 4 e 5, falharam em responder corretamente (P > 0.05), qual tipo de prótese foi apresentada, se mantendo, de maneira geral, dentro de um padrão aleatório de acerto. No Grupo 2 (Pós graduados em Periodontia/Implantodontia), em relação as próteses metalocerâmicas, o índice de acerto foi de 35,6% (P = 0.009), abaixo do índice aleatório, apresentando um resultado falso positivo. Conclusão: Os avaliadores foram incapazes de diferenciar de maneira significativa, qual tipo de prótese era cerâmica ou metalocerâmica nos 10 casos apresentados, comprovando assim, a hipótese de que as próteses metalocerâmicas ou cerâmicas são indistinguíveis ao olho humano, nas situações propostas pela metodologia deste estudo. / Objective: To evaluate the perception of postgraduates dentists in the areas of periodontics, implant dentistry, restorative dentistry and prosthodontics, to diagnose what type prosthesis, metal-free or porcelain-fused-to-metal (PFM), was used in the prosthetic rehabilitation of single-tooth implants in the lateral maxillary incisor region. Materials and Methods: Five single-tooth implants in the maxillary lateral incisor region were restored with two types of prostheses (PFM prosthesis and metal-free) directly screwed over the implant. Photographs were taken of both prostheses in position over the same the implant, totaling 10 images, which were presented to 20 evaluators. The evaluators were divided into five groups according to their area of expertise (Postgraduates in Periodontics/Implantology or Restorative Dentistry/Prosthodontics) and time of graduation in dentistry (over or under 10 years). The evaluators had to answer whether the prosthesis was: metal-free, PFM or could not tell. Results: Groups 1, 3, 4 and 5 failed to respond correctly (P > 0.05), which type of prosthesis was presented to him, remaining in a random pattern of accuracy. In Group 2 (Postgraduates in Periodontics/Implantology), in relation to metal-free prostheses, the accuracy rate was 35.6% (P = 0.009), below the random index, showing a false-positive result. Conclusion: The evaluators were unable to significantly differentiate which type of prosthesis, being it free of metal or PFM, was used in the 10 presented cases, thus, proving the hypothesis that PFM or metal-free prostheses are indistinguishable to the human eye in the situation proposed by the methodology of this study.
37

Avaliação da resistência de união entre dentes de resina e bases de próteses em função de diferentes tratamentos de superfície

Bragaglia, Lauro Egídio January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2013-07-15T22:48:38Z (GMT). No. of bitstreams: 1 224777.pdf: 6747022 bytes, checksum: 6a8d7dea84f7ac8b0a1b2d095ce4abfb (MD5) / A união entre os dentes artificiais utilizados nas próteses e a base das mesmas ocasionalmente falha. O objetivo deste estudo foi comparar a resistência de união entre bases de prótese e dentes de resina acrílica submetidos a seis tratamentos de superfície: CT - controle, superfície não alterada; MN - aplicação de monômero; OA - asperização com jato de óxido de alumínio; BR - remoção do brilho superficial com broca esférica; PE - asperização com pedra montada de óxido de alumínio e; CV - confecção de cavidade. As médias de resistência em kgf dos grupos foram: CT: 18,19(7,14), MN: 18,34(5,28), OA: 23,82(5,40), BR: 23,30(4,79), PE: 25,39(7,80) e CV:17,48(7,17). Houve diferença estatisticamente significativa apenas entre os grupos PE (melhor resultado) e CV (pior resultado) (p=0,037997).
38

Avaliação da resistência de união entre dentes acrílicos e reparos em resina acrílica

Tercero Munoz, Meredith Mabeth January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:20:26Z (GMT). No. of bitstreams: 1 321962.pdf: 6805738 bytes, checksum: 5b1cf0df5a79cd83853cc8b74c9a62fe (MD5) Previous issue date: 2013 / O objetivo deste estudo foi comparar a resistência da união ao cisalhamento entre dentes artificiais de resina acrílica e reparos em resina acrílica quimicamente ativada, após diversos tratamentos de superfície. Foram selecionadossetenta e dois dentes artificiais antero-superiores de resinaacrílica (MFT, Vita, Alemanha). Os espécimes foramdistribuídos aleatoriamente em seis grupos (n=12): G1-C:não receberam tratamento de superfície (controle); G2-M:foi aplicado monômero de metil-metacrilato (Jet, Clássico,Brasil) à superfície dos dentes, por 5min; G3-A: foiaplicado um agente adesivo à base de metil-metacrilato emetiletilcetona (Vitacoll, Vita, Alemanha) sobre asuperfície dos dentes de acrílico, por 5min. Os grupos G4-OA, G5-OAM e G6-OAA foram submetidos ao jato deóxido de alumínio com 45µm (Polidental, Wilson,SP/Brasil), sendo repetidos respectivamente os tratamentosdos grupos G1-C, G2-M e G3-A. Os espécimes foramreparados com resina acrílica quimicamente ativada (Jet,Clássico, Brasil). O teste de resistência de união aocisalhamento foi realizado em uma máquina de ensaiosmecânicos (Instron 4444). Para a comparação estatísticaforam utilizados ANOVA 2 e teste de Tukey com p<0,05.Os valores médios de resistência da união ao cisalhamentodos grupos G4-OA, G5-OAM e G6-OAA foramsignificativamente maiores (p<0,05) do que dos gruposG1-C, G2-M e G3-A. A resistência ao cisalhamento dogrupo G3-A foi significativamente mais elevada (p<0,05)do que a dos grupos G1-C e G2-M. Não houve diferençasignificativa (p>0,05) entre os valores médios deresistência de união dos grupos G4-OA, G5-OAM e G6-OAA, e nem entre os grupos G1-C e G2-M. Conclui-seque o tratamento químico com o agente adesivo à base demetil-metacrilato e metiletilcetona mostrou melhorassignificativas na resistência de união apenas quando o jatode óxido de alumínio não foi utilizado. O tratamento das superfícies com partículas de óxido de alumínio apresentou os maiores valores médios de resistência da união ao cisalhamento entre dentes artificiais e reparos de resina acrílica quimicamente ativada, independentemente da aplicação ou não de monômero ou adesivo.<br> / Abstract : The purpose of this study was to compare shear bondstrengths of denture teeth to autopolymerized repair acrylicresin after various surface treatments. Seventy-two upperanterior acrylic resin denture teeth (MFT, Vita, Germany)were selected. Specimens were randomly assigned into sixgroups (n=12): G1-C, acrylic teeth received no surfacetreatment (control); G2-M, methyl-metacrylate (Jet,Clássico, Brazil) was applied to the surface of the teeth for5 min; G3-A an adhesive agent (Vitacoll, Vita, Germany)was applied to the surface of the teeth for 5 min. Thesurface of G4-OA, G5-OAM and G6-OAA was airbondedparticleabraded with 45 µm aluminum oxide (Polidental,Wilson, Brazil); G4-OA received no additional surfacetreatment; G5-OAM was treated with methyl-metacrylate(Jet, Clássico, Brazil) for 5 min; and G6-OAA was treatedwith an adhesive agent (Vitacoll, Vita, Germany) for 5min. They were then repaired with autopolymerized acrylicresin (Jet, Clássico, Brazil). The shear bond strength testwas performed using a universal testing machine (Instron4444). Two-way ANOVA and post hoc Tukey?s analysisat p<0,05 were used for statistical comparison. The shearbond strengths of groups G4-OA, G5-OAM and G6-OAAwere significantly higher (p<0,05) than that of groups G1-C, G2-M and G3-A. The shear bond strength of Group G3-A were significantly higher (p<0,05) than that of groupsG1-C and G2-M. No significant difference (p>0,05) wasdetected for the bond strengths between groups G4-OA,G5-OAM and G6-OAA nor between groups G1-C and G2-M. Concluding that the chemical treatment with anadhesive agent showed significant improvement in thebond strength without the aluminum oxide treatment. Moresignificantly, treating surface with aluminum oxideparticles resulted in the highest bond strength values of thedenture teeth that had been repaired with autopolymerizedacrylic resin.
39

Avaliação do padrão superficial e geométrico de parafusos para retenção de próteses implanto-suportadas

Souza, Dircilene Colares de January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T13:06:40Z (GMT). No. of bitstreams: 1 203834.pdf: 3543184 bytes, checksum: a6214c4ff6b59467b73214809fcbf768 (MD5) / O objetivo deste trabalho foi analisar através de microscopia eletrônica de varredura (MEV) o padrão de fabricação de parafusos para retenção de próteses implanto-suportadas. A presença de irregularidades superficiais e parâmetros geométricos foram registrados em 87 parafusos divididos em 6 grupos das marcas comerciais 3i Implant Innovations; Nobel Biocare; Conexão Sistema de Prótese; Neodent; INP e Grupo Experimental. Os dados coletados foram submetidos a tratamento estatístico. Os resultados revelaram que todos os grupos apresentavam diferença estatisticamente significante em pelo menos um dos parâmetros observados dentro da sua amostra. Concluiu-se que todos os grupos avaliados apresentaram irregularidades e diferenças geométricas nos parafusos.
40

Controle da alteração dimensional térmica em estruturas metálicas de próteses sobre implantes

Vasconcellos, Diego Klee de January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T17:55:52Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T18:53:57Z : No. of bitstreams: 1 188216.pdf: 1163111 bytes, checksum: bd764a2faf25b2edf3dd58d3ae4a14f2 (MD5) / Estudo in vitro que analisou a eficácia do condicionamento térmico de estruturas metálicas de próteses sobre implantes, previamente aos ciclos convencionais para cocção da cerâmica, no controle da alteração dimensional do metal.. Sete estruturas de Níquel-Cromo formaram o grupo controle, e foram tratados de maneira convencional. As outras estruturas, da mesma liga, constituíram o grupo teste, e foram submetidos a condicionamento térmico, logo após a fundição, ainda no interior do revestimento. Nos dois grupos, constatou-se a alteração dimensional estatisticamente semelhante após os ciclos térmicos para a cocção da cerâmica. Constatou-se a importância do aquecimento da liga previamente à prova em boca das estruturas metálicas, pois permite a avaliação de seu assentamento com a maior parte da alteração térmica dimensional já manifestada.

Page generated in 0.074 seconds