• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação dos valores de destorque dos parafusos de titânio em pilares personalizáveis sobre implantes com hexágono externo

Medina, Carolina Enith Bullen January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-26T00:32:54Z (GMT). No. of bitstreams: 1 314860.pdf: 5500860 bytes, checksum: 1cbccbecc46b93e87b37e564d94aee77 (MD5) / Avaliar os valores de diferentes técnicas de destorque dos parafusos de titânio em pilares personalizáveis sobre implantes com hexágono externo. Metodologia: A amostra consistiu em 30 corpos de prova compostos pelo conjunto implante de hexágono externo (3,75mm de diâmetro e 10mm de comprimento), pilar personalizável e parafuso de titânio com encaixe para chave quadrada, que foram distribuídos aleatoriamente em três grupos (n=10): Grupo 1 - técnica convencional, com a aplicação de torque de 30N.cm; Grupo 2 - técnica descrita por Breeding e Dixon, com a aplicação de um primeiro torque de 30N.cm e, após 10 minutos, a aplicação de um novo torque com o mesmo valor inicial; e, Grupo 3 - técnica preconizada por Sella e Vasconcellos, com a aplicação de 30N.cm, mantendo o torque durante 20 segundos. Os corpos de prova foram fixados em uma base metálica e a mesma foi presa à base do equipamento universal de ensaio. Uma chave digital foi acoplada na célula de carga metálica, a qual possuía sensores que eram controlados por computador com o software ATMP2.2, a fim de controlar o valor do torque de 30N.cm a uma velocidade de 1N.cm/s, de acordo com a técnica de cada grupo experimental. Após 10 minutos da aplicação do torque, a máquina de ensaio foi programada para a aplicação do destorque, que foi realizado com os mesmos dispositivos utilizados para a aplicação do torque, com a mesma velocidade. Os valores de destorque dos três grupos foram submetidos à análise estatística pelo teste ANOVA e comparações individuais foram realizadas pelo teste HSD de Tukey. Resultados: As médias dos destorques encontrados foram de 27,95N.cm (DP ± 0,99) para o Grupo 1; 28,32N.cm para o Grupo 2 (DP ± 0,68); e, 26,89N.cm (DP ± 1,03) para o Grupo 3. Não houve diferença estatística entre os Grupos 1 e 2, porém, o Grupo 3 apresentou os menores valores de destorque, quando comparado com os outros grupos. Os valores de destorques obtidos em relação aos valores de torque foram menores para todos os grupos testados. Numericamente o grupo 2 apresentou valores maiores de destorque, porém, sem diferença estatística quando comparada com o grupo 1. O grupo 3 apresentou os menores valores de destorque, ou seja, menores valores de pré-carga / To evaluate the detorque values of titanium screws in customized pre-fabricated abutments with external hexagon implant. Methods: The sample consisted of 30 specimens formed by set of implant external hexagon (3.75 mm x 10mm ), customizable prefabricated abutment and titanium screw to fit square key, which were distributed randomly into three groups (n = 10): Group 1: the conventional technique, with the application of torque 30N.cm, Group 2: technique described by Dixon and Breeding, by applying a first torque 30N.cm and 10 minutes after the application of a new torque with the same initial value and Group 3: technique recommended by Sella and Vasconcellos, by applying 30N.cm, keeping the torque for 20 seconds. The specimens were fixed in a metal base and the same was attached to the base of the universal testing machine. Them a digital key was coupled to the metal load cell, which had sensors controlled by software computer ATMP2.2 in order to control the torque value of 30N.cm with a velocity of 1N.cm / s, according to the technique of each experimental group. After 10 minutes from application of torque, the test machine was programmed to implement detorque, which was performed with the same devices for the application of torque with the same speed. Detorque values of the three groups were statistically analyzed by ANOVA and individual comparisons were performed by Tukey's HSD test. Results: The mean destorques found were 27.95N.cm (SD ± 0.99) for Group 1; 28.32 N.cm for Group 2 (SD ± 0.68) and 26.89 N.cm (SD ± 1.03) for Group 3. There was no statistically significant difference between Groups 1 and 2, however, Group 3 showed lower values of detorque when compared with other groups. Conclusion: destorques values obtained were lower for all groups tested. Numerically group 2 have higher values of detorque, but no statistical difference when compared to group 1. Group 3 had the lowest values detorque, that is, lower preload.
22

Avaliação da retençao de coroas de Ytrio-zircônia cimentadas à diferentes substratos, com quatro agentes cimentantes, após termociclagem

Amaral, Regina [UNESP] 02 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-02Bitstream added on 2014-06-13T19:24:15Z : No. of bitstreams: 1 amaral_r_dr_sjc.pdf: 474843 bytes, checksum: ec47413ee9365a7ca21114ff7253d659 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve a finalidade de avaliar o efeito do tipo de substrato coronário (dentina e resina composta) na retenção de coroas cerâmicas de zircônia estabilizada por óxido de ítrio e comparar a retenção em função de diferentes protocolos. Para tanto, 144 molares recém-extraídos foram embutidos em resina acrílica, perpendicular ao seu longo eixo e preparados para coroa total, 72 permaneceram com o preparo em dentina e os demais, a parte coronária preparada foi removida e reconstruída em resina composta + pinos de fibra com dimensões idênticas à dentina preparada. Os preparos foram moldados com silicona de adição e dos troqueis foram obtidos 144 copings em YTZP, os quais apresentaram uma configuração especial para o ensaio de tração. Para ambos substratos, foi utilizado como grupo controle (n=12) um cimento à base de fosfato de zinco (sem condicionamento do substrato e da cerâmica). Os outros cimentos utilizados foram: um cimento à base de ionômero de vidro, um cimento resinoso da geração auto-condicionate (ambos sem condicionamento do substrato e da cerâmica) e um cimento Dual contendo monômeros fosfatados (MDP). Neste ultimo grupo, os remanescentes (dentina ou resina) foram condicionados com o adesivo correspondente do sistema e a cerâmica foi submetida a 3 tratamentos de superfície: álcool isopropílico, silicatização/silanização ou Vitrificação. Após 24h, todos os conjuntos foram submetidos a termocilagem (6000 ciclos) e incluídos em um dispositivo especial para o teste de tração em uma máquina de ensaio universal, para testar a retenção das infra-estruturas. Os modos de falha de todos os conjuntos foram analisados em estereomicroscópio e MEV para avaliar... / The aim of this study was to evaluate the effect of the crown substrate type (dentine and composite resin) in the retention of stabilized zirconia ceramic crowns by yttrium oxide (YTZP) and to compare the retention function of four types of cements, four treatments of the substrate surface and three treatments of the ceramic surface. For this purpose, 144 freshlyextracted molars were embedded in acrylic resin, perpendicular to the long axis and prepared for full crowns, 72 remained with the preparation in dentin and the other, the crown part was removed and reconstructed with composite resin + fiber pins with dimensions identical to the prepared dentin. The preparations were moulded with addition silicone and 144 YTZP copings were obtained, which presented a special setup for the tensile test. For the remainin, a phosphate-based cement zinc (unprimed substrate and ceramics) (n = 12) was used as the control group. The other used cements were: a glass-ionomer based cement, a resin cement from self-condicionating generation (unprimed substrate and ceramic) and a Dual cement containing phosphate monomer. In the latter groups, the remaining (dentin or resin) was conditioned with the adhesive system and the corresponding ceramic was subjected to three surface treatments: isopropyl alcohol, silica coating / silanization or Overglaze. After 24 hours, all sets were submitted to thermocycling (6000 cycles) and included in a special device for the tensile test in a universal testing machine to test the retention of the infrastructure. The failure modes of all sets were analyzed under a stereomicroscope and SEM to evaluate possible causes of failure. Data was analyzed statistically. The results showed that in dentin, the glass-ionomer... (Complete abstract click electronic access below)
23

Avaliação da atividade antimicrobiana de um reembasador resiliente combinado a um polímero antimicrobiano sobre a formação de bio-filme

Toda, Carina [UNESP] 14 November 2012 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-11-14Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000792872.pdf: 571447 bytes, checksum: 3bae358d477e471a159de61135729477 (MD5) / Este estudo avaliou a atividade antimicrobiana de um reembasador resiliente Coe Soft® (RRCS) combinado ao polímero antimicrobiano poli (2 tert-butilaminoetil) metacrilato (PTBAEMA) sobre formação de biofilme de Staphyloccocus aureus, Streptococcus mutans e Candida albicans. Espécimes circulares (15mm x 3mm) do RRCS foram confeccionados (n=27), esterilizados, divididos em três grupos de acordo com as concentrações de PTBAEMA a 0% (controle), 10% e 25% e individualmente inoculados em tubos de falcon contendo 5mL de caldo RPMI para os fungos, TSB para S. aureus e BHI para S. mutans e mantidos em overnight a 37ºC em incubadora com agitação orbital a 75rpm, sendo o S. mutans em microaerofilia. Após a inoculação dos espécimes seguiu-se a formação e maturação do biofilme a 37ºC sob agitação orbital a 75rpm. Em seguida cada espécime foi transferido para tubos contendo PBS e diluições seriadas foram realizadas. Alíquotas dessas diluições foram semeadas em placas de Petri e incubadas a 37ºC por 48h. Os dados obtidos foram transformados em log (UFC+1)/mL, considerando-se α=0,05. Os resultados demonstraram que o grupo contendo 25% de PTBAEMA inibiu completamente a formação de biofilme de S. aureus e S. mutans. Uma redução significativa na contagem de S. aureus e S. mutans (Kruskal- Wallis e Dunn; p=0,001) para o grupo contendo 10% de PTBAEMA foi observada quando comparada aos valores encontrados nos respectivos grupos controle. Para C. albicans não foi encontrada diferença significante entre grupos contendo PTBAEMA e o grupo controle (ANOVA; p>0,05). Conclui-se que os RRCS contendo 10% e 25% de PTBAEMA inibiram a formação de biofilme de S. aureus e S. mutans. Entretanto não teve efeito significante na formação de biofilme de C. albicans. / This study evaluated the antimicrobial activity of the resilient reliner Coe Soft ® (RRCS) combined with antimicrobial polymer poly (2-tert butylaminoethyl) methacrylate (PTBAEMA) on Staphylococcus aureus, Streptococcus mutans and Candida albicans biofilm formation. RRCS circular specimens were prepared (n=27), sterilized, divided into three groups according to PTBAEMA concentrations of 0% (control), 10% and 25% and inoculated into individual falcon tubes containing 5 mL of RPMI broth for fungi, TSB for S. aureus and BHI for S. mutans and kept overnight at 37°C with orbital shaking incubator at 75rpm, and S. mutans in microaerophilic. The specimens’ inoculations were followed by biofilm formation and its maturation at 37°C under orbital shaking at 75rpm. After that, each sample was transferred to tubes containing PBS and serial dilutions were performed. Aliquots of these dilutions were plated in Petri dishes and incubated at 37°C for 48h. The data were transformed into log (CFU +1)/mL, considering α = 0.05. The results showed that the group containing 25% of PTBAEMA inhibited completely biofilm formation of S. aureus and S. mutans. A significant reduction in counts of S. aureus and S. mutans (Kruskal- Wallis and Dunn; p = 0.001) were found in group containing 10% of PTBAEMA when compared to the values in the corresponding control groups. C. albicans had no significant differences between groups containing PTBAEMA and the control group (ANOVA; p> 0.05). It is concluded that the RRCS containing 10% and 25% PTBAEMA inhibited the biofilmformation of S. aureus and S. mutans. However, no significant effect was found on C. albicans biofilm formation.
24

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial /

Guiotti, Aimée Maria. January 2003 (has links)
Orientador: Marcelo Coelho Goiato / Abstract: The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey's Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn't have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection. / Mestre
25

Efeito da altura do pilar de diferentes cimentos e das ciclagens térmica e mecânica sobre a resistência máxima á tração de infraestruturas metálicas cimentadas

Alfenas, Bruna Fernandes Moreira [UNESP] 28 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-28Bitstream added on 2014-06-13T20:37:46Z : No. of bitstreams: 1 000738229.pdf: 1438062 bytes, checksum: 6eb2cc869f7ba5a30aaf8b01bd09ff16 (MD5) / Este estudo avaliou (1) o efeito da altura do pilar, dos diferentes cimentos e da termociclagem e (2) o efeito dos diferentes cimentos e da ciclagem mecânica sobre a resistência máxima à tração (RMT) de restaurações implantossuportadas cimentadas. Pilares de titânio (UCLA), com alturas de 4,0 e 6,0 mm (1), ou 4,0 mm (2), foram torqueados com 32 N.cm a análogos de implantes HI. Infraestruturas em Co-Cr, jateadas com óxido de alumínio 50 μm foram cimentadas com: Fosfato de Zinco- FZ; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 e RelyX Temp NE- RXTNE. Os conjuntos foram submetidos aos ensaios de tração (0,5 mm/min) após: 1- armazenagem em saliva artificial a 37 ºC durante 24 h (controle), 2- termociclagem (10.000 ciclos, 5,0 e 55 °C, 30 s de imersão), ou 3- ciclagem mecânica (106 ciclos, 140 N, 15 Hz). Os dados foram analisados por (1) 3- way ANOVA e Dunnett, e (2) 2-way ANOVA e Tukey HSD (α=0,05). Independentemente da altura do pilar, não houve diferença nos resultados dos grupos sem termociclagem (p≥0,05). Após termociclagem, houve aumento (p<0,05) na RMT nos pilares de 6,0 mm. Após ciclagem mecânica, houve diminuição (p<0,05) nos resultados de RMT produzidos por RXL2. A altura do pilar influenciou os resultados do RXL2, que produziu RMT mais elevada com os pilares de 6,0 mm. Com exceção do RXL2, a ciclagem mecânica não comprometeu a RMT das infraestruturas cimentadas. Em determinadas condições, o RXTNE produziu RMT semelhante à alguns cimentos finais. / This study evaluate (1) the effect of abutment height, different cements and thermocycling, and (2) the effect of different cements and cyclic loading on the ultimate tensile strength (UTS) of cement-retained/implant-supported cast restorations. UCLA-type abutments with 4.0 and 6.0-mm height (1), or 4.0-mm height (2) were torqued to with 32 N.cm to internal hexagon dental implant replicas. Copings casted in Co-Cr, sandblasted with 50-μm aluminum oxide particles were cemented with: Zinc Phosphate- ZP; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 and RelyX Temp NE- RXTNE. The assemblies were submitted to the tensile test (0.5 mm/min) after: 1- storage in artificial saliva at 37 °C for 24 h (control), 2- thermocycling (10,000 cycles, 5.0 and 55 ºC, 30-s dwell time), or 3- cyclic loading (106 cycles, 140 N, 15 Hz). Data were analyzed by (1) 3-way ANOVA and Dunnett tests, and (2) 2-way ANOVA and Tukey HSD tests (α=0.05). Regardless of the abutments’ heights, no significant differences were found among the UTS of the nonthermocycled groups (p≥0.05). After thermocycling, an increasing in the UTS was observed for the 6.0-mm abutments (p<0.05). After cyclic loading, the UTS values produced by RXL2 were decreased (p<0.05). The abutment’s heights used affected the RXL2 results, which produced higher results with the 6.0-mm abutments. With the exception of RXL2, cyclic loading did not detrimentally affect the UTS of the cemented castings. In some conditions, the provisional cement RXTNE produced similar UTS to some definitive cements.
26

Eficácia da imersão e da escovação mecânica combinada com diferentes agentes de limpeza de prótese na redução da viabilidade de biofilme multiespécies

Panariello, Beatriz Helena Dias [UNESP] 20 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-20Bitstream added on 2014-06-13T20:18:30Z : No. of bitstreams: 1 panariello_bhd_me_arafo.pdf: 907352 bytes, checksum: f72d55d051ab470ad1000ff37b63894e (MD5) / O objetivo deste estudo foi investigar a eficácia da escovação com diferentes agentes de limpeza para reduzir a viabilidade de um biofilme multiespécies em resinas acrílicas. Amostras de Lucitone 550 (L) e Tokuyama Rebase Fast II (T) (10 mm x 2 mm) foram preparadas, esterilizadas e inoculadas com uma suspensão de 107 células/mL de Candida albicans e Candida glabrata e de 108 células/mL de Streptococcus mutans. As amostras foram incubadas por 48 h a 37 °C para a formação do biofilme. Em seguida, foram divididas (n = 12) e submetidas à escovação ou imersão durante 10 s nas soluções: água destilada (A); ácido peracético 0,2% (Ac), digluconato de clorexidina 1% (Chx), solução água/dentifrício 1:1 (D), hipoclorito de sódio a 1% (NaOCl) e perborato de sódio (Pb). Os microrganismos viáveis foram avaliados por ensaio de XTT e contagem de colônias (ufc /mL). Os dados foram verificados por ANOVA e teste de Tukey com nível de significância de 5%. Neste estudo, a eficácia da remoção do biofilme foi aumentada pela escovação combinada com agentes químicos de limpeza, por outro lado, a imersão por 10 s em AC e NaOCl mostrou-se tão eficaz quanto a escovação em L e T. Este resultado é bastante interessante, pois a imersão nestes agentes de limpeza por um curto período poderia ser uma alternativa viável para a desinfecção de próteses de pacientes com dificuldades motoras para executar a escovação. / The aim of this study was to investigate the efficacy of brushing with different cleaning agents in reducing the viability of multispecies biofilm in acrylic resins. Lucitone 550 (L) and Tokuyama Rebase Fast II (T) specimens (10 mm x 2 mm) were prepared, sterilized and inoculated with a Candida albicans and Candida glabrata suspension of 107 cells/mL and a suspension of 108 cells/mL of Streptococcus mutans. Specimens were incubated for 48 h at 37°C for the biofilm formation. Then, they were divided (n=12) and subjected to brushing or immersion for 10 s in the solutions: distilled water (W), 0.2% peracetic acid (Ac), 1% chlorhexidine digluconate (Chx), 1:1 water/dentifrice solution (D), 1% sodium hypochlorite (NaOCl) and sodium perborate (Pb). Viable microorganisms was evaluated by XTT assay and colony counts (cfu/mL). Data were performed by ANOVA and Tukey test with 5% significance level. In this study, the efficacy of biofilm removal was increased by brushing combined with chemical cleaning agents, on the other hand, immersion for 10 sec in NaOCl and AC has shown to be as effective as brushing for L and T. This result is quite interesting, inasmuch as immersion in these cleaning agents for a short period could be a viable alternative for prostheses disinfection of patients with motor disabilities to perform the brushing.
27

Influência da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos de usuários de próteses totais

Mendoza Marin, Danny Omar [UNESP] 13 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-13Bitstream added on 2014-06-13T18:58:06Z : No. of bitstreams: 1 mendozamarin_do_me_arafo.pdf: 1018438 bytes, checksum: 1f8b0462d02af967b5cf054c1dc81a6d (MD5) / Objetivo: O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo “cross-over”. Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo os próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de “Wilcoxon” (α=0,05) e o “t-test” de student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. Resultados: O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. Conclusão: O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação / Objectives: The objective of this study was to evaluate the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Material and Methods: Fifty edentulous patients received one set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment: protocol 1- DA use during the first 15 days, followed by the no use of DA over the next 15 days; protocol 2- no use of DA during the first 15 days, followed by use of DA over the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to evaluate patients´ satisfaction and a kinesiograph instrument was used to record mandible movements and pattern of maxillary complete denture movement during chewing. Wilcoxon test (α=.05) and a paired sample t-test (α=.05) were used to compare satisfaction levels and kinesiographic data, respectively. Results: The use of DA improved the overall patients´ satisfaction (p<.001). Kinesiographic recordings revealed a significant increase (1.7mm) on vertical mandible movements (p<0,001) during chewing and a lower (.3mm) vertical intrusion of the maxillary complete denture (p=0,002) during chewing after use of DA. Conclusion: The use of a DA in complete dentures wearers improved the patients´ satisfaction and change mandible movements, with increases in vertical mandible movements during chewing and lower intrusion of maxillary complete denture
28

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial

Guiotti, Aimée Maria [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T18:35:15Z : No. of bitstreams: 1 guiotti_am_me_araca.pdf: 769780 bytes, checksum: 381f985ad016f2bce7728744d48fbe14 (MD5) / The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey’s Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn´t have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection.
29

Avaliação da resistência à fratura de intermediários cerâmicos submetidos à ciclagem térmica

Kikko, Ricardo Figueiredo 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T23:39:24Z (GMT). No. of bitstreams: 1 280594.pdf: 2933774 bytes, checksum: ac1e624316f650eb7eb9d7e505b28d57 (MD5) / Este estudo teve como objetivo avaliar o comportamento in vitro de intermediários cerâmicos usinados por um sistema manual quanto a sua adaptação cervical e resistência à fratura. Vinte intermediários cerâmicos foram distribuídos aleatoriamente em 2 grupos (controle e experimental) com 10 intermediários cada. O grupo experimental foi submetido à termociclagem (500 ciclos). Para as mensurações do grau de adaptação foi construído um aparato onde os intermediários foram fixados aos implantes e cada parafuso recebeu um aperto com 20Ncm. As mensurações foram conduzidas em um microscópio eletrônico de varredura, totalizando 3 medições para cada intermediário, em um aumento de 700X. Após, os intermediários foram embutidos em cilindros de PVC com resina acrílica autopolimerizável, submetidos ao teste de resistência à fratura com auxílio de um dispositivo em um ângulo de 45º e velocidade de 1,0mm/min. Os resultados demonstraram não haver diferença estatisticamente significante quanto à adaptação cervical entre os grupos testados, embora, numericamente, os menores valores tenham sido observados no grupo controle. Os resultados encontrados para a resistência à fratura mostraram-se estatisticamente significantes, sugerindo que o envelhecimento térmico diminuiu a resistência à fratura dos intermediários testados. / Discos em resina composta, liga prata-paládio e liga de ouro tipo IV foram utilizados como substratos. Trinta discos cerâmicos foram obtidos nos sistemas IPS-Empress e IPS-Empress2 em 3 espessuras distintas (1,5; 2,0 e 2,5mm). Estes foram associados aos substratos citados e um espectrofotômetro foi utilizado para mensurar as coordenadas L* a* b*. As médias das coordenadas obtidas foram comparadas com as médias-padrão das cerâmicas testadas nas espessuras preconizadas pelo fabricante, resultando nas diferenças de cor entre estas comparações. Análise de variância (p<0,05) foi realizada para cada cerâmica testada, considerando as diferenças de cor (?E), luminosidade (?L*), e cor das coordenadas de cromaticidade a* e b* (?a* e ?b*). Os resultados demonstraram diferenças estatísticas em todas as condições testadas para as duas cerâmicas, sugerindo que, durante a escolha de um sistema cerâmico, tanto o substrato como a espessura de material cerâmico devem ser considerados, principalmente nos sistemas restauradores sem infra-estrutura cerâmica.
30

Desenvolvimento de um simulador universal para ensaio de desgaste em próteses de quadril

DallaCosta, Daniela Águida Bento January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-26T05:14:24Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T20:47:36Z : No. of bitstreams: 1 299947.pdf: 4137178 bytes, checksum: 7ecbd61ed25109cf32f4d2c8c3b5e225 (MD5) / Ao longo das últimas décadas a artroplastia total do quadril com componentes fabricados em ligas metálicas apoiados sobre polietileno de ultra-alto peso molecular revolucionou o tratamento da osteoartrose avançada ao reduzir os problemas relacionados a infecções e fixação da prótese. Entretanto, as partículas geradas pelo desgaste do polietileno contra a cabeça metálica no par articulado e as consequentes reações biológicas adversas disparadas pelo organismo correspondem atualmente um dos mais relevantes problemas clínicos associado a esta cirurgia ortopédica. Neste sentido, toda nova tecnologia de par articulado metal-UWMHPE deve ser submetida a rigorosos e precisos testes in vitro de modo a comprovar que o projeto da prótese atenda de forma segura e eficaz as demandas das condições in vivo a que se destina. A realização destes ensaios laboratoriais pré-clínicos pressupõe o desenvolvimento, a fabricação e a validação de simuladores de força e movimento, ou seja, máquinas que mecanicamente buscam replicar a biomecânica das articulações humanas. O objetivo maior destes ensaios é estabelecer avaliações das características tribológicas da estrutura articular das próteses de modo a subsidiar a avaliação da segurança e eficácia dos projetos de próteses. Deste modo, os resultados de desgaste obtidos pelos simuladores devem indicar o desempenho satisfatório das superfícies de contato do par articulado. A revisão da literatura indica que os diferentes modelos de simuladores existentes fornecem resultados de desgaste distintos mesmo quando são testados os mesmos pares tribológicos. Esta dispersão de resultados origina questionamentos sobre a real relevância clínica dos ensaios realizados por diferentes tipos de simuladores e impede a comparação objetiva do desempenho tribológico de próteses de quadril. O presente trabalho apresenta o projeto preliminar de um simulador universal capaz de atender a uma ampla gama de protocolos de dinâmica e cinemática que reproduzam o campo de movimento e intervalo de forças da articulação do quadril em diferentes condições. A avaliação das trajetórias de deslizamento geradas na interface de contato da prótese pelo simulador universal indica que o mesmo é capaz de reproduzir os resultados de outros simuladores existentes, além de ser capaz de simular padrões cinemáticos e de força específicos que podem aportar maior relevância clínica ao teste. / Over the past decades, the total hip arthroplasty, with metal/polymer (UHMWPE) articulating surface has revolutionized the treatment of advanced osteoarthritis by reducing the problems related to infection and aseptic loosening of the prosthesis. However, the wear debris against metal head and the subsequent adverse biological reactions are the most important clinical problem associated with these procedures. In this sense, new technologies for articulating surface must undergo rigorous and accurate in vitro testing to evaluate the safety and effectiveness of the hip joint replacement. The wear of total hip prostheses can be evaluated using hip joint simulators where total hip prostheses are tested in conditions resembling as closely as possible those prevailing in the human body, usually in walking. The main purpose of designing the hip simulator is to reproduce the complex 3D articulations of walking. The main objective of these tests is the evaluation of articulating surfaces and measurement of the wear. The literature indicates that the wear results of simulators greatly differ from each other when testing the same prosthesis. The variation in results raises questions about the actual clinical relevance of the tests performed by different simulators and does not allow the comparison of hip prostheses tribological performance. The objective of this investigation is to develop a universal simulator able to meet a wide range of motion, load and lubrication that reproduce the kinematics of hip joint under different conditions. The slide tracks analysis of the prosthesis contact interface by the universal simulator proved that the system is capable of reproducing the results of different simulators and to assess the relationship between the kinematics of the test and clinical results.

Page generated in 0.0302 seconds